xcomfort Room Controller Touch User Manual xcomfort Room Controller Touch User Manual 0v17_EN

Similar documents
Lyric T6 & T6R Smart Thermostat

danfoss Heating Solutions 5

Model: RT510RF. Installation Manual

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

NO ONE DARES COME CLOSE O WNER S GUIDE 7756V

Roth Touchline. German quality since Quick and easy user manual 1/10

Model: Available in: Sapphire Black and Glacier White. 1 Series

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

Digital Room Thermostat

Application description

Model: Available in : Sapphire Black and Glacier White. 1 Series

DAY/TIME Button: Selects hour, minute and day setting.

Instruction FH-CWP Thermostat

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

ET4 heat/cool day RF programmable room thermostat. ET4 Receiver

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Model: RT310RF. Installation Manual

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

xcomfort Climate protection starts in your home

Digital Electronic Thermostat With RF

Roth Touchline. German quality since User manual quick and easy guide 1/10

Model: Touch-RF. 1 Wireless Series

Model: Slimline-RF. 1 Slimline Series

Modulating clock thermostat

Digital Electronic Thermostat With RF

USER S INFORMATION MANUAL

I2:00 Mo MODEL TSTATBBPB501 PROGRAMMABLE DIGITAL THERMOSTAT. Heat Pump & Heat Cool. Meets California Title 24 Residential USERS INFORMATION MANUAL

Installation and User Guide living connect Electronic Radiator Thermostat

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

ARATON 2100 TX 1 AURATON 2100 TX. Advanced Remote Control Programmable Thermostat

Color Touch Heating Thermostat WARMTEC WTS

QuickStat-TC Installation & Operation Manual

ALC-PACK3. WiFi Alarm System with HD WiFi Camera. User Manual. Your Watchguard Wireless Security professional:

IT801 Thermostat. User s Manual. The complete guide to the set up and operation of your new smart Wi-Fi thermostat.

T105 Advanced Remote Control Programmable Thermostat. User Manual

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Drayton Digistat +3RF

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Ambient Weather RC-8419 ClearView Radio Controlled Projection Alarm Clock with Indoor Temperature User Manual

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL

Contents 1 Set Up 2 Gateway information 3 Operation of the App 4 Troubleshooting Description of sensors. 1 Set Up. 1.1 Connect the Gateway

SA 2650 Kit User Manual

Thermostats & smart controls. neohub+ UNDERFLOOR HEATING HEAT PUMPS SOLAR THERMAL

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

TB8220U Commercial Programmable Thermostat OWNER S GUIDE

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Tebis application software

Room thermostat with Auto Timer, independent DHW

C-Stat 17-ZW User Instructions

installation guide digital timer thermostat

Model: Slimline-B. Battery Series

Operating Manual PU-27 Control Panel

RADIANT HEATING AND COOLING SYSTEMS CLIMATE CŎNTROL ZONING SYSTEM INSTALLATION GUIDE. Climate Cŏntrol Zoning System Installation Guide

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

Model: RT310. Installation Manual

CS027 User Instructions

Product Guide. Ceiling microwave presence detector DALI / DSI. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

User Manual THR842DUK Wireless Digital Thermostat

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Installer and User Manual. BeSMART. Thermostat WiFi Box and boiler RF receiver. Installer and User Manual ESC MODE SET PROG RESET

XR401. Comfort Control TCONT401AN21MA. Owner s Manual. your local dealer (distributor) For more information contact. Tyler, Texas 75711

xcomfort Climate protection starts in your home

Why Vaillant? Because there s smart and then there s vsmart. Vaillant vsmart. The USER Guide

i Van Intelligent Control Panel

Ambient Weather RC-8487 ClearView Radio Controlled Travel Alarm Clock with Indoor Temperature User Manual

OWNER S MANUAL. High-Wall Fan Coil Unit CONTENTS

SMART THERMOSTAT WITH HOT WATER CONTROL

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

INITIALIZATION / INSTALLATION

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

KNX Multitouch Pro. Menu of the KNX Multitouch Pro User manual. This document describes how to operate the user interface of the KNX Multitouch Pro.

O WNER S GUIDE M O D E L

RF Programmable Room Thermostat User Instructions

ES3247B. 3 Channel Programmer. User and Installation Instructions

Important information. Government Regulations and Safety information. Your Warranty. Replacement remote controls

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

Programmable Towel Radiator Manual

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

Operation and Maintenance Manual OM 897-3

Operation 8085C ENGLISH. Customer Support: or Visit our webiste Printed in China

Installer Manual KNX Touchscreen Thermostat

Keys for base station: 1. MODE 2. CHANNEL 3. MAX/MIN 4. UP/(C/F) 5. SET/(AL.ON/OFF) 6. DOWN/(12/24) 7. SNOOZE 8. ALERT 9. RESET

OWNER S MANUAL. R 410A Ductless Split System Air Conditioner and Heat Pump

MS7 Single Zone Mini Split System Air Conditioners and Heat Pumps

i Van Intelligent Control Panel The easy way to control your living environment Quick Guide

Room thermostat with Auto Timer, Option External Input

DAY/TIME Button: Selects hour, minute and day setting.

Installation and User Guide eco Intelligent Radiator Thermostat

Model: C87207 / C87061 Instruction Manual DC: DUAL ALARM CLOCK

Transcription:

xcomfort Room Controller Touch User Manual

For other languages and information about xcomfort, visit www.eaton.eu/xcomfort or www.xcomfort.com or use the QR-code. Für weitere Sprachen und Informationen zum xcomfort System besuchen Sie ww.eaton.eu/xcomfort oder www.xcomfort.de oder verwenden Sie den QR-code Besok www.xcomfort.no eller www.eato.eu/xcomfort for andre språk og mer informasjon om xcomfort eller bruk QR-koden. Pro další jazyky informace o xcomfort návštěvy www.eaton.eu/xcomfort nebo www.xcomfort.cz nebo použijte QR kód. Voor andere talen en meer informatie over xcomfort ga naar www.eaton.nl/xcomfort of www.xcomfort.nl of maak gebruik van de QR-code ii P a g e

Table of Contents 1. Introduction... 1 1.1 Safety instructions... 1 1.2 Intended use... 1 1.3 Instructions for disposal... 1 1.4 About this document... 1 2 The Room Controller Touch... 2 2.1 Operation... 2 2.2 Cleaning mode... 3 2.3 Replacing the batteries... 3 2.4 Operation mode... 4 2.4.1 Basic operations... 4 2.4.2 Enhanced operations... 4 2.4.3 Settings edit operations... 4 2.5 Basic Operating Instructions... 5 2.5.1 Show Current Room Temperature... 5 2.5.2 Show Current/Active Set-Point Temperature... 5 2.5.3 Temporarily adjust the current set-point temperature... 6 2.5.4 Switch active set-point temperature (operation mode)... 6 2.5.5 Show Room Humidity... 7 2.5.6 (Optional) Show outdoor temperature.... 7 2.5.7 (Optional) Show Time and Day of Week... 8 2.5.8 (Optional) Touch-button(s)... 8 2.6 Enhanced Operating Instructions... 9 2.6.1 (Optional) Activate/Deactivate Week Program... 9 2.6.2 (Optional) Selecting Heating and/or Cooling mode... 10 2.7 Edit Operating Instructions... 11 2.7.1 Change Pre-Defined Set-Point Temperature... 11 2.7.2 (Optional) Edit Week Program Timer... 13 2.7.3 (Optional) Edit humidity Set-point... 15 2.7.4 (Optional) Edit/Set Current Time and Date... 16 2.7.5 (Optional) Edit/Set Monthly clock correction factor... 18 iii P a g e

iv P a g e

1. Introduction 1.1 Safety instructions This document contains important warnings and safety instructions which must be observed and followed by the users. Failure to follow these warnings and safety instructions will put the fault-free operation of the Room Controller Touch at risk. 1.2 Intended use The Room Controller Touch has been designed solely for residential use in private homes and small offices. It is not suitable for industrial use. The Room Controller Touch is designed to facilitate the climate control in a room and provide the user access to this through an intuitive LCD Touch screen menu. The Room controller can operate in two application modes: Control mode; in which the Room Controller Touch controls the regulation of the climate in a room Sensor mode; in which the Room Controller Touch registers the room climate conditions and the user settings and sends them to an intelligent device, e.g. xcomfort Smart Home Controller (SHC), which actually controls the climate in the room. Since the transmission of radio signals is based on a non-exclusive communication channel, interference to the transmission are possible. Because of this, the Room Controller Touch must not be used to control components with safety-related functions, such as overheating protection, emergency stop or emergency call. The use of the unit for any purpose other than described in this document or the failure to observe the warnings and safety instructions it contains will immediately invalidate any claims in respect to the warranty and/or liability. 1.3 Instructions for disposal Do not dispose of this device with regular domestic waste. Electronic equipment must be disposed of at local collection points for waste electronic equipment and in compliance with the local regulations governing waste electrical and electronic equipment. 1.4 About this document These operating instructions are intended for end users and describe the operation and menu structure of the Room Controller Touch. Certain functions and their availability depend on the configuration of the Room Controller Touch during the installation. These functions are marked with (Optional). Please contact a suitable qualified electrical engineer for all assembly, installation and basic configuration requirements or if you need to remove or dispose of the device. Faulty installation or configuration can otherwise cause damage to property and persons. 1 P a g e

2 The Room Controller Touch 2.1 Operation The Room Controller Touch is equipped with a Display with Backlight and Touch function. The display is used to display the information through which, by touching the display, the Room Controller Touch can be operated. Note: The display is designed to respond to on-screen pressing only. Compared to the commonly used touch displays for smartphones and tablets it may be the case that touching the display a little more firmly is necessary. In the Idle-state the display shows the temperature and status with the backlight switched off. On touching the display it enters the Active-state. In this state, the backlight is switched on, and when connected to the xcomfort SHC, the information is refreshed to get the latest status. Note: To maximize the battery life, a delay between the information on the display in the idlestate and the actual status in the xcomfort SHC is possible. The maximum possible delay can be reduced by the installer, but this will lead to a reduction in the battery life. In other configurations the display always contains the latest information. Request status Heating request Cooling request Ventilation request Pre-defined temperature set-points Frost protection Night / Standby Economy Day / Comfort Shown information selection Temperature Humidity Clock Outdoor temperature Various Units of the shown information Setting Touch-button Floor temperature regulation active Low battery indication Week program timer Week program timer activity status Day of Week Program timer switch time-point 2 P a g e

2.2 Cleaning mode To prevent unwanted changes during the cleaning of the Room Controller Touch, the display can be put into the cleaning mode. The Room Controller Touch must only cleaned with glass cleaner or window cleaner, and never with abrasive products During the cleaning mode, the Room Controller Touch will ignore any touching on the display. The display shows the remaining time in seconds until the Room Controller Touch switches back to normal operation mode. >10 Sec. 2.3 Replacing the batteries The Room Controller Touch operates with 2x LR03 (AAA) batteries which are located in the rear section of the Room Controller. Replace the batteries when the low battery indicator is shown on the display. Note: Optionally, the Room Controller can also be used with an external mains power adapter. In this case batteries are not required. Contact your installer for more information. Do NOT press the center of the display to mount!! For the correct mounting, with two hands, simply press the outer frame of the Room Controller Touch. Used batteries should not be disposed of with regular domestic waste. They should be taken to a battery disposal point. Never recharge standard batteries!! This entails a risk of explosion. Do not throw the batteries into fires Do not short-circuit batteries 3 P a g e

2.4 Operation mode The operation functions of the Room Controller Touch are grouped into the following: Frequently used operation functions, Basic operation functions. Occasionally used operation functions, Enhanced operation functions Changes to the settings, Edit operation functions Note: To start operating the Room Controller Touch, touching the screen once is necessary to activate the display. To maximize the battery life, the Room Controller Touch display will enter the Idle-state. In this state, the display shows the temperature and status with the backlight switched off. On touching the display again it enters the Active-state. In this state, the backlight is switched on, and when connected to the xcomfort SHC, the information is refreshed to get the latest status. 2.4.1 Basic operations Show the current temperature Temporary adjust the current set-point temperature Show the current set-point temperature Select (another) per-defined set-point temperature (operation mode) Show the current humidity (Optional) Show outdoor temperature (Optional) Show time and Day of Week (Optional) Touch-button(s) 2.4.2 Enhanced operations Select regulation mode; Heating, Cooling, (Optional) Heating&Cooling or OFF mode (Optional) Switch Week Program Timer ON or OFF 2.4.3 Settings edit operations Edit pre-defined Set-point temperatures (Optional) Edit Week Program (Optional) Edit Humidity Set-point (Optional) Edit Time and Date (Optional) Edit clock correction factor 4 P a g e

2.5 Basic Operating Instructions 2.5.1 Show Current Room Temperature The default screen on the display shows the current temperature. After a timeout, the Room Controller will always return to this default screen. It is also possible to manually select the default current temperature screen. 2.5.2 Show Current/Active Set-Point Temperature The set-point temperature which currently is used for the regulation of the temperature in the room can be shown. Note: The active set-point temperature is the sum total of the active pre-defined operation mode set-point temperature and the temporary adjustment (increase or decrease) that is made. Initial Step 1 (Optional) Select the Heating or Cooling set-point Idle Timeout 5 P a g e

2.5.3 Temporarily adjust the current set-point temperature It is possible to temporarily increase or decrease the current set-point temperature. The temporary increase or decrease in the set-point temperature will be reset to zero when the operation mode (predefined set-point temperature) is changed, either manually or via the Week Program Timer. Note: To change the set-point temperature permanently, see the following section: Edit Operating Instructions - Change Pre-Defined Temperature Set-point. Initial Step 1 Optional Selection of Heating or Cooling setpoint Step 2 Idle Timeout 2.5.4 Switch active set-point temperature (operation mode) The Room Controller Touch supports four different pre-defined and reprogrammable set-point temperatures (operation modes) for an easy change in the desired (set-point) temperature during the day. It is possible to manually switch between these pre-defined set-point temperatures. The pre-defined set-points can also be used in the Week Program (when enabled) to switch automatically between the different set-point temperatures on a timed basis, Note: The Week Program will be switched OFF when the active set-point temperature (operation mode) is changed manually. 6 P a g e

Initial Step 1 Step 2 Idle Timeout 2.5.5 Show Room Humidity The Room Controller Touch also measures the humidity in the room, and the humidity can be displayed by selecting the display humidity screen. 2.5.6 (Optional) Show outdoor temperature. Sensor mode This option is available when the Room Controller is connected to an intelligent device which provides the outdoor temperature. Control mode The option is available in control mode if, during installation, the external temperature sensor input is configured for use as an outdoor temperature sensor. 7 P a g e

2.5.7 (Optional) Show Time and Day of Week Optionally, the current time can be displayed. The option is available in both the sensor mode and the control mode if the Week Program Timer is enabled during the installation. 2.5.8 (Optional) Touch-button(s) The Touch-buttons of the Room Controller Touch can be used as push buttons to control the lights, shutters/blinds in the room, for example, or to trigger Scenes in the xcomfort SHC. Note: To get the Touch-buttons, an actuator or intelligent device must be connected to the Touch-button of the Room Controller during the installation. Contact your installer for more information. The Room Controller Touch has up to two Touch-buttons. Their behavior depends on the configuration during the installation: 2x Single Pushbuttons: Each Touch-button is connected individually to an actuator(s) or to an intelligent device (e.g. the xcomfort SHC). The Touch-button acts as single pole pushbutton. The Touch-button supports short pressing (e.g. switch on/off) and long pressing (e.g. dimming up/down). 2x Single Rocker with arrow keys: Each Touch-button is individually connected to an actuator(s) or to an intelligent device (e.g. xcomfort SHC). When the Touch-button is pressed it will start flashing, and the arrow keys are shown, which can be used up or down. In this respect on the up key, apply a short press to switch on and a long press to dim up. Press briefly on the down key to switch off or to dim down. 1 Single Rocker: Both Touch-buttons are connected to the same actuator(s). The pair of Touchbuttons behave as one 2 pole pushbutton. The Touch-button on the left is the ON/UP (short/long press) part and on the right the OFF/DOWN part. 8 P a g e

2.6 Enhanced Operating Instructions 2.6.1 (Optional) Activate/Deactivate Week Program The Week Program can be optionally deactivated (OFF) or activated (ON). When it is OFF, it is only possible to manually switch between the pre-defined set-point temperatures (operation mode), and when it is ON, the operation mode is based on the programmed week program. Control mode If the Week Program Timer function is enabled during the installation (MRF), the option to activate or deactivate the Week Program is available in the control mode only. Sensor mode In the Sensor mode the option is available when connected with the xcomfort SHC (e.g. Room Manager), otherwise the Week Program is not available. Note: If the Week Program is activated (ON), then the operation mode will switch to the correct operation mode according to the week program for the current time. Optional Step 1 Step 2 Deactivated (OFF) Activated (ON) Step 3 Timeout 9 P a g e

2.6.2 (Optional) Selecting Heating and/or Cooling mode It is possible to select which temperature regulation mode should be active manually. (OFF) No icons displayed. No heating or cooling, e.g. regulation switch off. Heating mode. Regulation based on heating set-point(s) temperature only. Cooling mode. Regulation based on cooling set-point(s) temperature only. Heating&Cooling mode. Regulation based on both heating and cooling set-points temperature. Sensor Mode If the Room Controller is connected to an xcomfort SHC, it is possible to change manually between heating, cooling and OFF. In this case, the Heating&Cooling mode is not available. When connected to a Room Manager the temperature regulation mode cannot be changed. Control Mode * The available regulation modes depend on the configuration. If a heating or a cooling actuator is connected only, then it is only possible to switch between heating and OFF / cooling and OFF manually. If both actuators are connected, then all modes are available. Optional Step 1 (Show mode) Current active mode is shown Step 2 (Select mode) Control Mode* (OFF) Optional Sensor Mode (OFF) Timeout 10 P a g e

2.7 Edit Operating Instructions 2.7.1 Change Pre-Defined Set-Point Temperature The Room Controller Touch supports up to 2 x 4 (4 for heating and 4 for cooling) different pre-defined set-point temperatures (operation modes) which can be manually (re-)programmed via the screen. Frost protection mode. Factory default values 10 C/32 C (or -5K with Room Manager) Standby or Night mode. Factory default values 18 C/28 C (or -0,5K with Room Manager) Economy mode. Factory default values 19 C/26 C (or -1K with Room Manager) Comfort or Day mode. Factory default value 21 C/24 C (or 0K with Room Manager) Sensor mode When connected to the xcomfort SHC, the values of the pre-defined temperature are the same as the set-point temperatures in the SHC. Making a manual change on the Room Controller Touch will also change the set-point in the SHC (and v.v.). When connected to a Room Manager, the predefined temperatures are used as offset in the Room Manager for the Room Manager s current set-point temperature. Control mode The initial values used in controller mode are programmed during the installation (MRF). The set-point values are used by the Room Controller Touch for the climate control. Note: If the Heating&Cooling mode is active, the Room Controller will maintain a minimum temperature difference between the heating set-point and cooling set-point temperature (dead zone) to prevent the continuous switching between heating and cooling. This dead zone value can be configured during installation. The factory default is 3K. Optional Step 1 11 P a g e

Enter Edit mode Step 2 (Select Edit) Enter Edit Set-point temperature Optional Select the Set-point Repeat this for other set-points when required Step 3 (Change) Leave Edit mode Step 4 Optional Select the Heating or Cooling Set-point Timeout or Edit icon flashing Changed value is flashing Idle Timeout 12 P a g e

2.7.2 (Optional) Edit Week Program Timer Sensor mode When connected to an intelligent device, the climate control is carried out by the intelligent device and based on the Week Program programmed in the intelligent device. Changes to the Week Program should therefore be made in the intelligent device. Control mode In the control mode, the Week Program Timer is available if it is enabled during the installation (MRF). The Room Controller Touch supports up to 6 manually (re-)programmable points for each Day of Week at which time the Room Controller Touch should switch the active set-point temperature (operation mode), and to which of pre-defined set-point temperatures (operation mode) it should switch. Step 1 Step 2 Enter Edit mode Step 3 (Select Edit) Step 4 (Enter Program edit) Edit icon flashing Enter Edit Program Select Day of Week Repeat this The Day of week and Trigger point are flashing Selected is flashing: - The Day of the Week or - Midweek: (Mo + + Fr) or - Weekend: ( Sa + Su) 13 P a g e

Select Switch point Selected Switch point is flashing To change the pre-defined set-point Change Pre defined Set-point Selected Set-point has an underscore To Change the Time minutes Change Time minutes Step 1 (Select) Minutes are flashing Step 2 (Change) To Change the Time hours Change Time Hour Step 1 (Select) Hours are flashing Step 2 (Change) 14 P a g e

Leave Edit mode Step 6 (Leave Edit mode) Timeout or Idle Timeout 2.7.3 (Optional) Edit humidity Set-point Sensor mode The Humidity set-point is not available if the Room Controller is connected to an intelligent device, e.g. SHC or Room Manager. Control mode This option is available in control mode if a humidity actuator is connected to the Room Controller Touch during the installation. The Room Controller Touch will send an OFF command to the actuator if the humidity is above the set-point value, and it will send an ON command if the actual humidity is below the set-point value. The set-point value can be changed manually. Initial select Humidity Edit mode Enter Change 15 P a g e

Leave Timeout or 2.7.4 (Optional) Edit/Set Current Time and Date Sensor Mode The option to set the Time and Date manually with the Room Controller is not available if the Room Controller is connected to an xcomfort SHC. In this case, the time and date are synchronized with the xcomfort SHC date and time. Control Mode The Time (Hours, Minutes) and Date (Day of Week, Day of Month, Month and Year) can be set manually if the Week Program is enabled during installation. Initial select Clock Attention: The time and date are used for the execution of the Week Program. The Time and Date need to be set correctly for the correct operation of the Week Program Enter Edit Mode 16 P a g e

Select Item and change Select Number (1-6) is flashing Hours Minutes Day of Week Repeat this step for each items that needs to be changed Change Use the arrow-keys to change Day of Month Month Year When changed the changed numbers starts flashing Leave Edit Mode Timeout or 17 P a g e

2.7.5 (Optional) Edit/Set Monthly clock correction factor Any inaccuracy to the Room Controller Touch internal clock can be corrected by configuring the number of seconds that the clock needs to be corrected by each month (-99 to +99 seconds). Note: The accuracy of each clock may vary slightly, which can make the clock go out of sync with the current time. This results in the Week Program switching to the desired set-point temperature too early or too late. The option is only available if the clock function is enabled during the installation and if the Room Controller does not receive the time and date from another device. Initial select clock Enter Edit Press Edit > 5 Sec Change Leave Edit 18 P a g e

19 P a g e

Eaton Industries (Austria) Eugenia 1 3943 Schrems Austria www.xcomfort.com www.eaton.eu/xcomfort 20 P a g e