Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Similar documents
MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

LOW STATIC HYDRONIC DUCTED UNIT

Product Specifications. Vertical Floor Consoles By First Co.

Duct Type Fan Coil Unit. Air flow: 680~4590m 3 /h Cooling capacity: 3.7~22.6kW

Ceiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz)

technical data Fan coil unit FWB small duct unit

EHH SERIES DRAW THROUGH FAN COILS CFM

YAH SERIES FAN COIL UNITS

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

Product Catalog. DCHC Horizontal Concealed Chilled Water Fan Coil with DCBL Motor Airflow: 180~2380 m 3 /h

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

On the cover Integrated professional services designed for your unique business need.

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

42CW/CH. Fan Coil Unit (High Static Pressure) 42CW/CH. Welcome to Carrier Website w w w. c a r r i e r. c o m. c n

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

DAZZLE TM series Cassette Type Fan Coil Unit. FC-NHDU4 Cassette Type Fan Coil Unit 340~2380 m 3 /h

SKYPAK II, 3 Ton Series, gives you a

SKYPAK II Heating & Cooling Self Contained Packages

SeasonMaker ThinLine Fan-coil Units

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Concealed Ducted Split Series R-407C MBH

SKYPAK II, 3 Ton Series, gives you a

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

Modular Air Cooled Scroll Chillers

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

SeasonMaker ThinLine Fan-coil Units

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

R410A50Hz Universal Outdoor Series Technical Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

VERTICAL FAN COIL UNITS

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Evaporadoras Hidrónicas

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

UniTrane Ductable Units D-line and B-Line

Product Data. Features/Benefits. OMNIZONE 50BRN,BZN Water-Cooled and Remote Air-Cooled Indoor Self-Contained Systems. 5 to 20 Nominal Tons

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

VRV+AHU System DAIKIN NEW STANDARD SERIES UNIT MODEL AHUR-CA/SA

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

E U R O V E N T CERTIFIED PERFORMANCE

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

PACKAGE AIR CONDITIONER

Q-TEC QC-Series Chilled Water Air Conditioner

photo by PFC Price Fan Column

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog

Conditioning your ambient, maximising your comfort.

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

Q-Tec TM QC-Series Chilled Water Air Conditioner

Rooftop Packaged Unit 10kW-110kW. Vicot Air Conditioning Co., Ltd

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

EC Motor Fan Coil Units. IMD-Y Series l/s

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

MHW Air Handling Unit (50/60Hz)

YAH Series Air Handling Units

KCC Centrifugal Fan Air Cooled Condensers

Chilled Beam/Induction Unit

Aegean Range. A new range of fan coils for heating and cooling commercial applications

CHH - Active Chilled Beam. Halton CHH. Active Chilled Beam

Chilled Water Fan Coil Unit. Model:HFCA Size 03-14

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Large Capacity Fan Coil Units Belt and Direct Drive Cabinet and Hideaway

FCC Fan-Coil Units High-Performance, Vertical

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Highly Efficient,Powerful Heating and Cooling.

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Product Specifications NEW OPTION AVAILABLE: AUTOSPEED 24V CONTROL PACKAGE

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Technical documentation DTR

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

JCseries EVAPORATIVE CONDENSER. engineering data

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

HOTEL CHILLED BEAM IQ STAR SILENCIA

COOLflow 4E PRODUCT RANGE

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Transcription:

Fan Coil Unit 1 BOSCH Climate 000 Fan Coil Unit

2 Fan Coil Unit Introduction to Bosch Thermotechnology Bosch Thermotechnik GmbH is a leading supplier of resourceefficient heating products and hot water solutions in Europe. In fiscal 2011, the company generated sales of 3.1 billion Euros (68% outside Germany) and employed approx. 13,900 people. Bosch Thermotechnology has strong international and regional brands and manufactures a diversified product range in 21 plants in 11 European, North American and Asian countries. In 2011, Bosch Thermotechology invested 127 million Euros in research and development, roughly 10.4% more than in the previous year. Intelligent networks and local systems for heating, ventilation, air-conditioning and electricity generation are fundamental technologies for the future building standard, which will generate more energy than is used. Bosch Thermotechnology (Shandong) Co. Ltd is a division of Bosch Thermotechnology with focus on providing energy efficient cooling, heating and comfort hot water equipment & solutions for commercial and industrial segments. The division employs aprox. 260 people with more than 40 engineers, and has a plant of 80000sqm with state-of-art manufacturing facility and high-demanding quality management system. A comprehensive range of renewable heat pumps, chillers, fan coil units and air handling units meets almost all kinds of requirement from buildings like office, hospital, hotel, shopping mall or industrial plants. Bosch Climate 000 fan coil unit with galvanized fan is a product engineered with most advanced technology which brings you great energy savings, and an ultimate quiet and comfortable working/living environment. Nomenclature BOSCH Climate 000 FC 02 CC 23 / 1 P1 L G E Export (Out of CN) Product Sequence: G: with galvanized fan L: Left R: Right Static Pressure: P1: 12Pa; P2: 30Pa; P3: 0Pa; Power Supply: 1=V/0Hz/1 Phase Coil Layout: 23: 2 Pipes-3 Rows Product Type: CC: Ceiling Concealed without Plenum & Filter CD: Ceiling Concealed with Down Return Plenum & Filter CB: Ceiling Concealed with Back Return Plenum & Filter Air Flow: 100 CFM Fan Coil

Fan Coil Unit 3 Explosive View 1) High Efficiency AC motor High quality AC motor works with reliable bearings. Fan and motor are preciously adjusted for dynamic balance before leaving the factory. 2) Galvanized Fan & Volute High efficiency large centrifugal fan ensures strong and constant air fow. Axises and bearings have been special treated for longer service life. 3) Heat Exchanger Complex High quality hydrophilic fins and seamless copper tubes are made into state-of-art heat exchangers, ensuring a smooth and even energy transfer. 4) Drain Pan with Insulation The enlarged drain pan has a two degree slope to ensure a smooth drainage and is covered with mm PE insulation to avoid external condensation. ) Return Plenum and Washable Nylon Filter Changeable air return plenum can be done easily at job-site with screw driver only.(backside to downside air return or downside to backside air return). Product is equipped with washable nylon filter if with air return plenum, Aluminum filter is optional. 6) Removable End Panel End panels on both sides can be removed; coil connection orientation can be easily changed on jobsite. 7) Leakage-tight Header This safe and secure header structure is perfectly designed, aiming at totally leakage-free and durable operating performance. 2 1 3 7 6 4

4 Fan Coil Unit Features 1 2 3 4 High energy efficiency Bosch Climate 000 Fan Coil Unit is the new energy saving products engineered with most-advanced technology by Bosch Thermotechnology. High efficient heat coil is manufactured by mechanically expanded copper pipe with open-window hydrophilic aluminium fins with state-of-art techniques. The strengthened air supply of the large diameter impeller fan makes the maximum heat transfer efficiency of the unit. Wide range choice Bosch Climate 000 Fan Coil Unit has wide offering with airflow 170~2380m3/h, and cooling capacity 1.4~13.18kW, and product is available with configuration of with back return plenum, or with down return plenum, or without air return plenum. In order to meet all the possible applications, 12Pa, 30Pa, 0Pa esp. is also available. Extended drain pan, stainless steel drain pan is optional. Low Noise The unit use the latest wide wheel and low speed forward-curved blades, dynamically balanced and adjusted with the motor, plus the high performance low noise bearing. The Unit casing is equipped with good noise eliminate insulation materials. Thus lead to a lower noise than the conventional products. Most Compact Design The unit height is only mm the most compact thus saves lots of installation space and can meet all kinds of diverse applications. Which also makes the installation easier. Height Comparison Height: mm 23 230 22 21 210 A B C D Bosch FCU Flexible design The unit has been carefully designed with a changeable air return plenum, thus it can be easily changed as simply as with screw driver only. From backside to downside air return or from downside to backside air return

Fan Coil Unit Specifications Fan Coil Unit (Two-pipe Three Rows) Model FC02 FC03 FC04 FC0 FC06 FC08 FC10 FC12 FC14 Air Flow H 340 10 680 80 1020 1360 1700 2040 2380 m 3 /h M 260 380 10 640 770 1020 1280 130 1790 L 170 260 340 430 10 680 80 1020 1190 Total Cooling H 2370 3260 4100 4840 630 7740 9400 11200 13180 Capacity M 1870 240 2930 3740 4480 920 7400 8940 10420 W L 140 1760 2120 2730 3240 4290 370 610 780 Sensible H 170 200 230 3020 3490 4880 970 7200 820 Cooling M 120 130 1810 2320 270 3730 4700 720 6480 Capacity W L 90 1110 1300 1680 2009 2690 3400 4180 4740 Heating H 3980 260 680 7410 9470 12680 14410 17160 20190 Capacity W M 3210 390 4900 740 70 9690 11340 13700 1970 L 2600 2840 30 4190 40 7030 8230 9970 11610 Power Input 12Pa H 36 2 8 82 94 143 166 186 226 W 30Pa H 43 8 78 87 108 146 187 211 271 0Pa H 47 6 80 101 126 16 200 240 326 Noise Level 12Pa 36 38 40 42 44 4 47 49 1 db(a) 30Pa 39 41 43 4 46 47 49 1 3 0Pa 41 43 4 46 48 49 1 3 4 Fan Galvanized Forward Curve Centrifugal Fan Motor Type AC Motor Insulation Class Power Supply B ACV±10%, 1Ph/0Hz Coil Type Seamless copper mechanically expanded into aluminum fins Max. Working Pressure 1.6MPa Inlet/Outlet Water Pipe FPT 3/4 Condensate Water Pipe 20mm Water Flow H 41 71 718 847 987 136 1649 1962 2313 kg/h Water Pressure H 18 24 28 30 32 36 38 40 42 Drop kpa Net Weight w/o plenum kg 13.2 16.2 16.2 16.2 18 23.3 28.8 28.8 33.6 Net Weight c/w plenum kg 1.7 19.6 19.6 19.6 21. 28.3 34.2 34.2 39. Dimensions W 880 1030 1030 1030 1180 100 1660 1660 1930 D 466 466 466 466 466 466 466 466 466 H Notes: 1.Nominal Testing condition: Cooling: entering air temp 27 C DB/19. C WB; entering water temp 7 C, leaving water temp 12 C; Heating: entering air temp 21 C; entering water temp 60 C, the same water flow as in cooling; 2.H, M and L stand for high, medium and low speed; 3.Sound pressure level are measured in acoustic room, position of the measure point is 1m in the front and 1m below the vertical center line of the unit; 4.Static pressure is measured without filter and air outlet (no air return box).

6 Fan Coil Unit Dimensions Without Plenum 47 100 With Back Return Plenum 100 With Down Return Plenum 164 11 482 100 237 164 11 49 164 47 30 C B A Lifting hole 4-12x22 49 D 30 C B A Lifting hole 6-12x22 482 F=11 E=170 F=11 F=11 D G=167 30 C B A Lifting hole 6-12x22

Fan Coil Unit 7 Model Without Plenum With Plenum A(mm) B(mm) C(mm) Weight(kg) A(mm) B(mm) C(mm) D(mm) Weight(kg) FC02 80 638 608 13.2 80 638 608 74 1.7 FC03 1000 808 778 16.2 1000 808 778 744 19.6 FC04 1000 808 778 16.2 1000 808 778 744 19.6 FC0 1000 808 778 16.2 1000 808 778 744 19.6 FC06 110 938 908 18 110 938 908 874 21. FC08 1470 1238 1208 23.3 1470 1238 1208 1174 28.3 FC10 1630 1498 1468 28.8 1630 1498 1468 1434 34.2 FC12 1630 1498 1468 28.8 1630 1498 1468 1434 34.2 FC14 1900 178 1728 33.6 1900 178 1728 1694 39. Correction Factors Cooling Capacity Correction Factors EWT (C) 6 7 8 9 10 11 12 Correction Factor 1.1 1.07 1 0.92 0.8 0.77 0.7 0.62 Note: air side condition, entering DB 27C, WB 19.C. Heating Capacity Correction Factors EWT (C) 3 40 4 0 60 6 70 Correction Factor 0.36 0.49 0.62 0.74 0.87 1 1.13 1.26 Note: air side condition, entering DB 21C. Cooling Capacity Correction Factors Based on Different Ambient Conditions WB (C) DB (C) 24 2 26 27 28 29 30 17 0.76 18 0.8 19 0.94 19. 1 20 1.06 21 1.1 22 1.2 Note: entering cooling water temperature 7C. Heating Capacity Correction Factors Based on Different Ambient Conditions DB (C) 18 19 20 21 22 23 24 Correction Factor 1.1 1.07 1.02 1 0.97 0.94 0.9 Note: entering hating water temperature 60C.

8 Fan Coil Unit Fan Curve Bosch Fan Coil Unit with ESP 12Pa External Static Pressure (Pa) 40 FC02 FC03 FC04 FC0 FC06 FC08 FC10 FC12 FC14 30 20 1 12 10 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Air Flow(100m 3 /h) Bosch Fan Coil Unit with ESP 30Pa External Static Pressure (Pa) FC02 FC03 FC04 FC0 FC06 FC08 FC10 FC12 FC14 40 30 20 10 2 4 6 8 10 12 14 16 18 20 22 24 26 28 Air Flow(100m 3 /h)

Fan Coil Unit 9 Bosch Fan Coil Unit with ESP 0Pa External Static Pressure (Pa) 80 FC02 FC03 FC04 FC0 FC06 FC08 FC10 FC12 FC14 70 60 0 40 30 20 10 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Air Flow(100m 3 /h) Water Flow-Pressure Drop Bosch Fan Coil Unit Water Pressure Drop (kpa) 2 48 44 40 36 32 28 24 20 16 12 8 4 0 FC02 FC03 FC04 FC0 FC06 FC08 FC10 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 FC12 FC14 Water Flow(100kg/h)

10 Fan Coil Unit Installation Installation of Fan Coil Unit without Plenum 2 1 10 12 13 14 1 16 View A 3 4 6 7 8 11 17 9 1 Building Floor 2 Flexible Joint 3 Filter 4 Return Air Grille Return Air 6 Return Air Duct 7 Fan Coil Unit 8 Air Delivery Duct 9 Outlet Air 10 Flexible Joint 11 Diffuser 12 Building Floor 13 M8 Expansion Bolt 14 M8 Screw 1 M8 Gaskets 16 M8 Nut 17 Fan Coil Unit With Back/Down Return Plenum 1 3 4 1 Building Floor 2 2 Return Air 1 3 Return Air Grille (During Installation, Please Note that there should be Enough Space left to Install Filter after the Grill is Removed) 4 4 No Barrier in Front of Outlet Air Grille 3 Outlet Air 2 The above installation diagrams are for informational purpose only. Any changes may be made based on site conditions during installation so as to improve air-conditioning effects and facilitate maintenance.

Fan Coil Unit 11 Wiring diagram Ultra-high High speed Capacitor Electric motor 2 Medium speed Low speed Yellow / green Earth wire Capacitor Electric motor 1 Ultra-high High speed Medium speed Low speed Red Blue Black Orange Yellow Ultra-high High speed Medium speed Low speed Neutral wire Note: 1. Connect terminal block s low, medium, high and ultra-high speed to fan coil s controller (or three-speed switch). 2. When ESP is 0 or 12 Pa, the fan coil controller is wired to low, medium and high speed; -When ESP is 30 Pa, the fan coil controller is wired to medium, high speed and ultra-high speed; -When ESP is 0 Pa, the fan coil controller is wired to medium, high speed and ultra-high speed; -Also, users may make an on-site change on demand. 3. Single-motor fan coil has no electric motor 2 and corresponding wiring.

Bosch reserves the right to change any specification, design and information without any prior notice for further improvement on quality and performance. 201408A