McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

Similar documents
McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

McQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017

Climate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982

McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008

CME1856W Service Parts

Air Cooled Scroll Compressor Condensing Unit

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018

AFE400 SERVICE PARTS

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018

CME1856W Service Parts

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL

CMS1402 SERVICE PARTS

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

Product Data. Single-Package Horizontally Mounted Water Source Heat Pumps with Electronic

PARTS LIST GEOTHERMAL HEAT PUMPS HRH/HRV & HOT WATER GENERATOR HWG

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

SCE170 SERVICE PARTS

Effective october 14, 2014

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com

CME1056 Service Parts. Table of Contents

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012

Humidifiers Dealer Parts List Model 400/400M Humidifiers

REPLACEMENT PARTS MANUAL

NM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...

Commercial High-Efficiency Condensing Units

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016

Parts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com

MARVAIR CLASSIC HEAT PUMPS MODELS AVP HP EXPLODED VIEW PARTS ID

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Humidifiers Dealer Parts List

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0806, ICE1006 Includes 50Hz. and 3 Phase Units

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

RP8.1Y (ERRATA 1) (202) 2 of 8

McQuay Enfinity (R-410A) and Standard (R-22) Horizontal Water Source Heat Pumps

UNIVERSAL 750 PRE-MIX DISPENSER

Catalog McQuay Enfinity Horizontal & Vertical Water Source Heat Pumps

RED DOT UNITS HEATER-A/C. Heater/Air Conditioner/Defroster Unit OFF-ROAD CONSTRUCTION INDUSTRIAL OPTIONS. Shown with optional louvers

Humidifiers. Model 400/400M Humidifiers NO. BLUE/GRAY UNITS - PART NAME QTY/CTN PART NO. PART NO.

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8

TSC & TSC-M Proofer/Oven

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

Parts List. Modular Crescent Cuber. Models KM-340MAJ, MWJ. hoshizakiamerica.com

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

Replacement Parts List For Models COS-20G

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

REPLACEMENT PARTS MANUAL

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606

MDT2 Service Parts. Table of Contents Cabinet Page 2. Condensing System Page 3. Water and Dispensing Page 4. Water and Dispensing Part Numbers Page 5

Parts List. Modular Crescent Cuber. Models KMD-460MAH, MWH KMD-530MAH, MWH, MRH. hoshizakiamerica.com

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

GUIDE SPECIFICATIONS AQUARIUS ii

McQuay Enfinity TM. Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton. Catalog

Hoshizaki America, Inc.

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

NM1850 SERVICE PARTS

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Vertical V*B Series Fan Coil Technical Catalog

GUIDE SPECIFICATIONS AQUARIUS ii

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

PARTS LISTS GAS/T... 1 GAW... 3 GBS/T... 5 GES/T... 6 GFS/T... 8 GFW... 9

Effective october 14, 2014

June PRODUCT DESIGN GUIDE Whisperline Console

Daikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017

REPLACEMENT PARTS MANUAL

MDT6N SERVICE PARTS TABLE OF CONTENTS. Cabinet PAGE 2. Hopper PAGE 3. Sink PAGE 4. Ice Chute and Dispensing PAGE 5. Air Cooled Refrigeration PAGE 6

Condensing Unit Installation and Operating Instructions

McQuay Horizontal Water Source Heat Pump 1/2 to 6 Ton

Condensing Unit Installation and Operating Instructions

SECTION WATER-SOURCE UNITARY HEAT PUMPS

Concealed Ducted Split Series R-407C MBH

REPLACEMENT PARTS MANUAL

ENGINEERING SPECIFICATIONS

Transcription:

Replacement Parts List No. 055236000 Revision B 06/2015 McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 048, 060 Vintage A Last Manufactured: 1995 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

Contents Parts List Revision History...3 Nomenclature Serial Number...4 Model Number...4 Field Installed Accessories Thermostats and Subbases For Electromechanical Control Units...5 Thermostats and Subbases For Mark IV Units...5 Thermostat Accessories...6 Hoses, Valves & Filters...6 Unit Accessories...7 Refrigeration Circuit Diagram...8 Components...9, 10 Fan and Housing Assembly Diagram... 11 Components...12 Control Box Standard Control Layout- 60 Hz...13 Standard Control Layout- 50 Hz...14 Components...15, 16 Critical Parts List CCH,CCG,CCW 048...CPL1 CCH,CCG,CCW 060...CPL2 WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 2

Parts List Revision History Rev. Date A 07/01 Revised all pages to be consistant with electronic style, added Revision History page. Page 12- added ( 1 ) footnote to Bub. #15 last 4 motors. B 06/15 Part number conversion. Remove sheet metal for chassis and cabinet components. Page 4- Add Model Number codes. Page 15- Change Circuit Board, Electromechanical p/n 060679202K to 060679202. Change Mark IV Circuit Board p/n 060638806 to 056792401K. Add Footnote #4 Service Bulletin for Mark IV Board. Change Air & Water Temp Sensor p/n 4EZS9158 to 106110801. CPL1 & CPL2 Add Critical Parts List. Daikin Applied,13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330 WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 3

Nomenclature Serial Number 7 Z A 00000 00 Plant Identification Number 7 = Auburn Year Manufactured S = 1987 T = 1988 U = 1989 Etc Model Number Engineering Revision Serial Number (Building Sequence) Month Manufactured A = January B = February C = March D = April E = May F = June G = July H = August J = September K = October L = November M = December CCH 048A F G S 1 1 W R F SDR A Y A Y 1 D M C Code 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 Code 01= Model Type CCH= Ceiling Concealed Heat Pump CCG= Ceiling Concealed Cooling Only CCW= Ceiling Concealed Heat Pump, Extended Range Code 02= Unit Size/Vintage 048A= 4800 BtuH Nominal Cooling 060A= 6000 BtuH Nominal Cooling Code 03= Control System E= Electromechanical Controls M= Mark IV Controls C= MicroTech Unit Controller Code 04= Voltage F= 208- G= 208- Q= T= W= Code 05= Discharge Air Arrangement S= Straight Discharge E= End Discharge Code 06= Construction Type 1= Standard E= Extra Quiet Code 07= Water to Refrigerant Heat Exchanger 1= Copper Inner Tube C= Cupro-Nickel Inner Tube Code 08= Head Pressure Control W= Water Regulating Valve Y= None Code 09= Starting Control R= Random Start (C03=E) Y= None Code 10= Drain Pan Overflow Protection F= Float Switch (C03=E) Y= None Code 11= Controls SDR= Shutdown Relay (C03= E & C04= J) NSR= Night Setback Relay (C03= E & not C04= J) NSD= NSR & Demand Control Relay (C03= E & not C04= J) SDN= SDR & NSR (C03= E & not C04= J & Not Vintage A) MTR= Timed Output Relay (C03=C) MBS= Boilerless System Relay (C03=C) MFD= Fresh Air Damper (C03=C) MTV= Motorized Valve (C03=C) YYY= None Code 12= Auxiliary Relay A= Auxiliary Relay (C11 is not SDR & SDN; C03= E or M) Y= None Code 13= Always Y Code 14= Filter A= Throw Away Y= None Code 15= Paint (Y= None) Code 16= Finned Tube Coil 1= Copper Tube/Aluminum Fin Code 17= Fan Housing/Wheel & Motor D= Direct Drive, 2-Speed Motor E= Direct Drive, 2-Speed Oversize Fan Code 18= Logo & Nameplate Designation M= Snyder General C= Climate Control (C04= J) Code 19= Construction C= Chicago Code (C04= not J) Y= None Code 20= Agency Listing Code 21= Warranty Code 22= Packaging Code 23= Miscellaneous WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 4

Field Installed Accessories Thermostats & Subbases. For Electromechanical Control Units only. Model No. Digit 7 = E. STANDARD MANUAL CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T834C with no LED. Mounts vertically. System "Heat-Off-Cool" switch and fan. "On-Auto" switch. STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE. Thermostat Honeywell T874/Q674. LED for "Service." Mounts horizontal. System "Off-Auto" switch and fan "On-Auto" switch. Subbase DELUXE AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE WITH NIGHT SETBACK. Honeywell T874/Q674. LED for "Service." Thermostat Mounts horizontal. Requires factory installed night setback relay or field installed night setback or night setback/demand control relay. Night setback bulb set 8 o F below day heating setpoint. System "Off-Auto" Subbase switch and fan "On-Auto" switch. Requires minimum of 6 wires. PROGRAMMABLE MICROELECTRONIC THERMOSTAT. Digistat HP-2000DC. Auto or manual changeover. Mounts horizontal. System "Off-Auto" switch, temp. "Heat-Auto-Cool" switch and fan "On-Auto" switch. Part Number 803005245 (Includes subbase) 060687201 060687401 060687301 060687401 060602301 (Includes subbase) Thermostats & Subbases. For Mark IV Control Units only. Model No. Digit 7 = M. STANDARD MANUAL CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T834C with no LED. Mounts vertically. System "Heat-Off-Cool" switch and fan. "On-Auto" switch. STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T874/Q674. LED for "Service." Mounts horizontal. System "Off-Auto" switch and fan "On-Auto" switch. Subbase STANDARD MANUAL & AUTO CHANGEOVER THERMOSTAT & Thermostat SUBBASE. Honeywell T874/Q674. LED for "Service." Mounts horizontal. System "Off-Heat-Auto-Cool" switch and fan "On-Auto" switch. Subbase DELUXE AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE WITH NIGHT SETBACK AND OVERRIDE. Honeywell T874/Q674. Thermostat LED for "Service." Mounts horizontal. Requires grounding of unit "U" terminal. Night setback bulb set 8 o F below day heat setpoint. Night setup Subbase bulb set 6 o F above day cool setpoint. System "Off-Auto" switch and fan "On-Auto-Override" switch. STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE Thermostat FOR OPERATING TWO UNITS. Honeywell T874/Q674. LED for "Service." Mounts horizontal. System "Off-Auto" switch. Subbase PROGRAMMABLE MICROELECTRONIC THERMOSTAT. Digistat HP-2000DC. Auto or manual changeover. Mounts horizontal. System "Off-Auto" switch, temp. "Heat-Auto-Cool" switch and fan "On-Auto" switch. Part Number 803005245 (Includes subbase) Thermostat 060685301 060684801 060685301 060684901 060685501 060684801 060685201 060684701 060602301 (Includes subbase) WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 5

Field Installed Accessories Thermostat Accessories NIGHT SETBACK THERMOSTAT. Honeywell T822. Mounts vertically. No LED. No switches. For applications requiring a separate NSB stat. UNIVERSAL THERMOSTAT GUARD. Honeywell TG500A. Clear plastic with ring base, lock and keys. DELUXE LOCKING COVER FOR T874/Q674 THERMOSTATS. Honeywell TG504A. Applies only to T874/Q674 thermostats. Replaces standard thermostat cover. Includes cover, lock and keys. ADAPTER PLATE FOR T874/Q674 THERMOSTATS. Allows for horizontal thermostat to be mounted on a vertical junction box. 7-DAY TIME CLOCK. Not available for 50 cycle power. Includes spring carryover. OVERRIDE TIMER - 1 HOUR. OVERRIDE TIMER - 6 HOUR. Part Number 803005180 802005426 060684501 802007673 802005716 802005717 802005718 Hoses, Valves & Filters Part Number STANDARD SUPPLY OR RETURN HOSE. Rubber hose with MPT 2' long, 3/4" I.D. (Size 048) 802025405 swivel hydraulic fittings on each end. Order two per unit. 2' long, 1" I.D. (Size 060) 802025414 3' long, 3/4" I.D. (Size 048) 802025406 3' long, 1" I.D. (Size 060) 802025415 FIRE RATED SUPPLY OR RETURN HOSE. Stainless steel, braided 2' long, 3/4" I.D. (Size 048) 802025602 hose with one MPT and one MPT swivel fitting. Order 2 per unit. 2' long, 1" I.D. (Size 060) 802025611 3' long, 3/4" I.D. (Size 048) 802025603 3' long. 1" I.D. (Size 060) 802025612 CONDENSATE HOSE ASSEMBLY. Requires trap by others. Clear plastic, 38" long 060687701 Order one per unit. Fire rated, 24" long 060688801 Includes fitting to be soldered on unit. Fire rated, 36" long 060688802 BALL VALVE. Combination shutoff and balancing valve with memory 3/4" FPT (Size 048) 802026098 stop. Order two per unit. 1" FPT (Size 060) 802026109 RETURN AIR DUCT COLLAR & TWO INCH FILTER RACK. Four sheet metal pieces to hold 1" or 2" thick filter and to allow for easy connection of return air duct onto its 1" collar. 060672224 Replaces standard brackets. 2" THICK THROWAWAY FILTER. Fits into 2" thick filter rack. Must order in multiples of 12. 060687103 (2 req'd. per unit). 1" THICK THROWAWAY FILTER. Replacement for standard filter. Must order in multiples of 12. 060604803 (2 req'd. per unit). 1" THICK CLEANABLE FILTER. Must order in multiples of 12. (2 req'd. per unit.) 060687004 2" THICK PLEATED FILTER, 35% EFFICIENT. Must order in multiples of 12. (2 req'd. per unit.) 060759803 WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 6

Field Installed Accessories Unit Accessories SHUTDOWN RELAY KIT FOR ELECTROMECHANICAL CONTROL UNITS. For shutdown of the unit from an external 24 volt AC power source. Relay mounts at control box. NIGHT SETBACK RELAY KIT FOR ELECTROMECHANICAL CONTROL UNITS. Relay to put unit into NSB mode from an external 24 volt AC power source. Relay mounts at control box. Operation requires ACO stat with built-in NSB or a separate NSB stat. NIGHT SETBACK/DEMAND CONTROL RELAY KIT FOR ELECTROMECHANICAL CONTROL UNITS. Relay to put unit into NSB mode from one 24 volt AC power source and to put unit into load shed mode from another 24 volt AC power source (3 total wires required). Relay mounts at control box, operation requires ACO stat with built-in NSB or separate NSB stat. RANDOM START RELAY FOR ELECTROMECHANICAL CONTROL 115, 208/230, 265V UNITS. Time delay relay to delay compressor startup when coming off night 460, 575V operation and to not allow all units to start at the same time. CONDENSATE OVERFLOW SAFETY SWITCH FOR ELECTROMECHANICAL CONTROL UNITS. Float switch in drain pan to shut down compressor operation when pan fills. AUXILIARY RELAY. 24 volt DC relay to be wired to low voltage terminal block to allow a set of SPDT pilot duty contacts to operate miscellaneous devices when the fan or compressor operate. BOILERLESS SYSTEM KIT. Must be Mark IV control unit. Includes electronics and sensor to lock out compressor operation at 50 o F to 60 o F EWT and provide SPNO contacts to a field supplied electric heater control system. LOGIC LINK II. Must be Mark IV control unit. Includes electronics, ACO stat and subbase for adjustable night setback and setup and compressor only shutdown (demand control/load shed) from a 24 volt AC external power source. Also includes 1 hour override control at the thermostat. LOGIC LINK II WITH BOILERLESS SYSTEM. Incorporates both Logic Link and Boilerless System control in one package. Includes ACO stat and subbase, and EWT sensor. Requires 24 volt AC external power source. MULTIPLE UNIT CONTROL PANEL. Allows master unit to be controlled by any thermostat. Slave units "follow" with paralleled operation. Master & 1 Slave Master & 3 Slaves Kit Not recommended with Boilerless System. Circuit Board only Relay only (3 req'd.per unit) MOTORIZED VALVE. Includes prewired valve/ operator, 3 foot conduit assembly with leads and quick connects. Valve shuts water flow off for variable pumping. 300 psig maximum operating pressure. Requires control relay. See below. CONTROL RELAY FOR MOTORIZED VALVE. Unit Size 048 3/4" FPT Unit Size 060 1" FPT Kit with bleed port Valve only with bleed port Kit without bleed port Valve only w/o bleed port Kit with bleed port Valve only with bleed port Kit without bleed port Valve only w/o bleed port Kit Relay only Part Number 802005291 802005728 802007881 802005496 802005498 803005260 803005073 060844701 060845001 060846001 803005159 859002819 802005857 802005872 859004352 802026204 060977301 060976901 859004353 802026203 060977201 060976801 859004354 803005073 WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 7

Refrigeration Circuit Diagram To Water Regulating Valve (Option) 2 6 7 5 4 8 3 9 10 11 12 1 WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 8

Refrigeration Circuit Components 048 060 Ref. No. Part Number 1 Compressor 1,2 060604201 1 1 1 Compressor 3 060743901K 1 1 1 Compressor 1,2 060604203 1 1 1 Compressor 3 060743903K 1 1 1 Compressor 1,2 060604202* 1 1 Compressor 3 060743902K 1 1 Compressor 1,2 060604204 1 1 Compressor 3 060743904 1 1 Compressor 1,2 802003406 1 1 1 Compressor 1,2 802003404 1 1 1 Compressor 3 802003412 1 1 1 Compressor 1,2 802003405 1 1 1 Compressor 3 802003413 1 1 1 Compressor 3 802003414 1 1 Compressor 1,2 802003407 1 1 Compressor 3 802003415 1 1 Compressor 802003410 1 N/S Threaded Plug, 1/2" - 13 802028117 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Capacitor 40 MFD 440V 802007858 1 1 N/S Capacitor 55 MFD 440V 060630902 1 1 N/S Capacitor Bracket 850010570 1 1 1 1 2 Condenser, Coax 1,2,5 Copper Inner Tube 060999501 1 1 1 1 1 1 1 1 1 2 Condenser, Coax 3,5 CUNI Inner Tube 060999502 1 1 1 1 1 1 1 2 Condenser, Coax 1,2,4 Copper Inner Tube 060836301 1 1 1 1 1 1 1 2 Condenser, Coax 3,4 CUNI Inner Tube 060836302 1 1 1 1 1 1 1 2 Condenser, Coax 1,2 Copper Inner Tube 060602501 1 1 1 1 1 1 1 2 Condenser, Coax 3 CUNI Inner Tube 060602502 1 1 1 1 1 1 1 N/S Spring Nut, U Type 802017006 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 Evaporator Coil 060623601 1 1 1 1 1 1 1 3 Evaporator Coil 060604701 1 1 1 1 1 1 1 4 Capillary 36 X.064 X.125 802001106 5 5 5 5 5 5 5 7 7 7 7 7 7 7 5 Strainer / Distributor 060676202 1 1 1 1 1 1 1 5 Strainer / Distributor 060676201 1 1 1 1 1 1 1 N/S = Not shown on diagram * If serial number ends in 'T4' compressor is Tecumseh P/N 60618103. 1 CCH 2 CCG 3 CCW 4 Used on Serial number revision levels -01 & -02. 5 Used on Serial number revision level -03. Continued on next page. WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 9

Refrigeration Circuit Components- Continued 048 060 Ref. No. Part Number 6 Reversing Valve 802026142 1 1 1 1 1 1 1 1 1 1 1 1 1 1 7 Solenoid, Reversing Valve 1,3 802026121 1 1 1 1 1 1 1 1 1 1 1 1 1 1 8 Switch, High Pressure 060605401 1 1 1 1 1 1 1 1 1 1 1 1 1 1 9 Switch, Low Pressure 060605501 1 1 1 1 1 1 1 1 1 1 1 1 1 1 10 Thermostat, Low Temp Cutout 1,2 066540601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 10 Thermostat, Low Temp Cutout 3 066540603 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 Speed Clip, Thermostat 802017215 1 1 1 1 1 1 1 1 1 1 1 1 1 1 12 Accumulator 3 802025539 1 1 1 1 1 1 1 12 Accumulator 3 060721901 1 1 1 1 1 1 1 N/S Flanged Nut Compr., Mounting 802012035 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Grommet, Compressor Mounting 6 802003084 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Sleeve, Compressor Grommet 6 31313600 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Sleeve, Compressor Grommet 7 44074900 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Spacer, Lower Compressor Mtg. 7 60687901 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Spacer, Top, Compressor Mtg. 7 60687801 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Spring, Compressor Mounting 7 60688001 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Valve, Water Regulating 1,2,8 02026198 1 1 1 1 1 1 1 N/S Valve, Water Regulating 3,8 02026162 1 1 1 1 1 1 1 N/S Drain Pan Assy * 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S = Not shown on diagram * Please contact Daikin Applied with unit model and serial number for part numbers on Cabinet/ Chassis components. 1 CCH 2 CCG 3 CCW 4 Used on Serial number revision levels -01 & -02. 5 Used on Serial number revision level -03. 6 Used only on Standard Construction units built prior to Serial number Engineering Revision "02". 7 Used on all units (Standard and Extra Quiet Construction) starting with Serial Number Engineering Revision "02". 8 Used only on units with Water Regulating Valve Option. WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 10

Fan and Housing Assembly 18 16 17 22 20 19 Straight Discharge is standard. 15 21 End Discharge same as standard except rotated 180 o. WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 11

Fan and Housing Components 048 060 Ref. No. Part Number 15 Motor, 3/4 HP 060704701 1 1 1 1 1 1 1 1 15 Motor, 3/4 HP 060704702 1 1 15 Motor, 3/4 HP 060704703 1 1 15 Motor, 3/4 HP 060704704 1 1 15 High Static Motor, 3/4 HP 1 060915001 1 1 1 1 15 High Static Motor, 3/4 HP 1 060915002 1 15 High Static Motor, 3/4 HP 1 060915003 1 15 High Static Motor, 3/4 HP 1 060915004 1 N/S Motor Mount 062200601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 16 Run Capacitor 15 MFD 370V 802007844 1 1 1 1 1 1 1 1 1 1 1 1 16 Run Capacitor 10 MFD 370V 802007063 1 1 17 Bracket, Capacitor 850010570 1 1 1 1 1 1 1 1 1 1 1 1 1 1 18 Blower Housing 060699605 1 1 1 1 1 1 1 1 1 1 1 1 1 1 18 Blower Housing 1 060899501 1 1 1 1 1 1 1 19 Inlet Ring 60829001 1 1 1 1 1 1 1 1 1 1 1 1 1 1 19 Inlet Ring 1 60899101 2 2 2 2 2 2 2 20 Wheel- Blower 02000039 1 1 1 1 1 1 1 1 1 1 1 1 1 1 20 Wheel- Blower 1 60899201 1 1 1 1 1 1 1 21 Support Bracket 60607101 1 1 1 1 1 1 1 1 1 1 1 1 1 1 21 Support Bracket 1 60609501 1 1 1 1 1 1 1 22 Protector Terminal 02007316 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Blower Cutoff 1 60899001 1 1 1 1 1 1 1 N/S Band, Motor Mounting 02009140 1 1 1 1 1 1 1 N/S Arm, Motor Mounting 1 60899401 3 3 3 3 3 3 3 N/S = Not shown on diagram 1 Used only on units with High Static Fan Assembly Option, (Size 060 only). WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 12

Control Box Standard Control Layout- 60HZ 32 29 33 35 31 43 30 27 28 36 26 37 38 Front View Side View WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 13

Control Box Standard Control Layout- 50HZ 32 29 33 39 42 34 40 41 43 31 35 30 27 28 37 36 26 38 Front View Side View WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 14

Control Box Components 048 060 Ref. No. Part Number 26 Circuit Board, Mark IV 3 until 3/05 060638806 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Circuit Board, Mark IV, DC 4 3/05 & later 056792401K 1 1 1 1 1 1 1 1 1 1 1 1 1 1 26 Circuit Board, Electromechanical 3 060679202 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Circuit Board, Microtech 2 060959401 1 1 1 1 1 1 1 1 1 1 1 1 27 Stand-Off 3 802028130 5 5 5 5 5 5 5 5 5 5 5 5 5 5 27 Stand-Off 1 802028130 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Stand-Off 2 802028130 1 1 1 1 1 1 1 1 1 1 1 1 N/S Nut, Nylon 2 802012415 7 7 7 7 7 7 7 7 7 7 7 7 7 7 28 Nut, Nylon 1 802012415 4 4 4 4 4 4 4 4 4 4 4 4 4 4 28 Nut, Nylon 3 802012415 1 1 1 1 1 1 1 1 1 1 1 1 29 Control Box 060604401 1 1 1 1 1 1 1 1 1 1 1 1 1 1 30 Low Voltage Guard 060606501 1 1 1 1 1 1 1 1 1 1 1 1 1 1 31 Mount, P.C. Board 060606401 1 1 1 1 1 1 1 1 1 1 1 1 1 1 32 Contactor, Compressor 1,3 803005105 1 1 1 1 32 Contactor, Compressor 1,3 803005193 1 1 1 1 32 Contactor, Compressor 1,2,3 803005222 1 1 1 1 N/S Contactor, Compressor 2 803005223 1 1 1 1 32 Contactor, Compressor 1,3 803005233 1 1 33 Relay, Fan 1,3 802005906 1 1 33 Relay, Fan 1,2,3 802005819 1 1 1 1 N/S Relay, Fan 2 047356506 1 1 1 1 1 1 1 1 34 Cup Washer, Ground Screw 802007455 1 1 1 1 1 1 1 1 1 1 1 1 N/S = Not shown on diagram 1 Electromechanical Control units only. (Units with Model No. Digit 8 = E). 2 Microtech Control units only.(units with Model No. Digit 8 = C). 3 Mark IV Control units only. (Units with Model No. Digit 8= M). 4 Mark IV Control units - When replacing reversing valve and/or coil refer to Service Bulletin WS-SB-20070423. Continued on next page. WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 15

Control Box Components- Continued 048 060 Ref. No. Part Number 35 Relay, Random Start 1,4 802005496 1 1 1 1 1 1 1 1 1 1 1 1 35 Relay, Random Start 1,4 802005498 1 1 36 Relay, Shutdown 1,5 802005291 1 1 1 1 1 1 1 1 1 1 1 1 1 1 37 Relay, Night Setback 1,6 802005728 1 1 1 1 1 1 1 1 1 1 1 1 1 1 37 Relay, Demand Control, Bd Galt 1,7 802007881 1 1 1 1 1 1 1 1 1 1 1 1 1 1 38 Relay, Auxiliary 8 803005073 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Relay, Timed Output 1 802005206 1 1 1 1 1 1 1 1 1 1 1 1 N/S Relay, Boilerless System 1 802005206 1 1 1 1 1 1 1 1 1 1 1 1 N/S Relay, Fresh Air Damper 1 802005206 1 1 1 1 1 1 1 1 1 1 1 1 N/S Relay, Motorized Valve 1 802005206 1 1 1 1 1 1 1 1 1 1 1 1 39 Angle Bracket 060760401 1 1 40 Terminal Block 802007432 2 2 N/S Terminal Block 2 3-Pole 049759001 1 1 1 1 1 1 1 1 1 1 1 1 N/S Terminal Block 2 4-Pole 049759002 1 1 1 1 1 1 1 1 1 1 1 1 41 End, Terminal Block 802007431 1 1 42 Terminal Lug 802007744 1 1 43 Transformer 1,2,3 208/240V - 24V 060614101 1 1 1 1 1 1 1 1 1 1 43 Transformer 1,2,3 480V - 24V 060676001 1 1 43 Transformer 1,2,3 575V - 24V 060676101 1 1 N/S Transformer 2 9V -24V 060949301 1 1 1 1 1 1 1 1 1 1 1 1 N/S Air & Water Temperature Sensor 2 until 12/99 4EZS9158 2 2 2 2 2 2 2 2 2 2 2 2 Air & Water Temperature Sensor 2 12/99 & later 106110801 2 2 2 2 2 2 2 2 2 2 2 2 N/S Clamp, Sensor 2 061040301 2 2 2 2 2 2 2 2 2 2 2 2 N/S Circuit Breaker 803007113 1 1 1 1 1 1 1 1 1 1 1 1 N/S = Not shown on diagram 1 = Electromechanical Control units only. (Units with Model No. Digit 8 = E). 2 = Microtech Control units only. (Units with Model No. Digit 8 = C). 3 = Mark IV Control units only. (Units with Model No. Digit 8 =M). 4 = Only on units with Random Start Relay Option. 5 = Only on units with Shutdown Relay Option. 6 = Only on units with Night Setback Option. 7 = Only on units with Demand Control Option. 8 = Only on units with Auxiliary Relay Option. WSHP; CCH, CCG & CCW, Sizes 048 & 060, Vintage A Rev. B 06/15 RPL 0552360 / Page 16

Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 048 Vintage A Critical Components Model Unit Size Voltage Part Number Control Control Board, Mark IV, DC ALL 048 N/A 056792401K Control Board, Electromechanical ALL 048 N/A 060679202 Control Board, Microtech ALL 048 N/A 060959401 Compressor Compressor CCH, CCG 048 208-060604201 Compressor CCW 048 208-060743901K Compressor CCH, CCG 048 208-060604203 Compressor CCW 048 208-060743903K Compressor CCH, CCG 048 060604202 Compressor CCW 048 060743902K Compressor CCH, CCG 048 060604204 Compressor CCW 048 060743904 Compressor CCH, CCG 048 802003406 Fan Motor Motor, 3/4 HP ALL 048 208-/3 060704701 Motor, 3/4 HP ALL 048 060704702 Motor, 3/4 HP ALL 048 060704703 Motor, 3/4 HP ALL 048 060704704 Fan & Housing Assembly Blower Housing & Wheel ALL 048 N/A 060699605 Wheel- Blower ALL 048 N/A 802000039 Sensor Air & Water Temp Sensor ALL 048 N/A 106110801 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call 1-800-37PARTS 552360 Rev. B 06/2015 CPL Page 1 of 2

Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! McQuay Ceiling Concealed Horizontal Water Source Heat Pump CCH, CCG, CCW 060 Vintage A Critical Components Model Unit Size Voltage Part Number Control Control Board, Mark IV, DC ALL 060 N/A 056792401K Control Board, Electromechanical ALL 060 N/A 060679202 Control Board, Microtech ALL 060 N/A 060959401 Compressor Compressor CCW 060 208-802003404 Compressor CCH, CCG 060 208-802003412 Compressor CCH, CCG 060 208-802003405 Compressor CCW 060 208-802003413 Compressor CCH, CCG 060 802003406 Compressor CCW 060 802003414 Compressor CCH, CCG 060 802003407 Compressor CCW 060 802003415 Compressor ALL 060 802003410 Fan Motor Motor, 3/4 HP ALL 060 208-/3 060704701 Motor, 3/4 HP ALL 060 060704702 Motor, 3/4 HP ALL 060 060704703 Motor, 3/4 HP ALL 060 060704704 High Static Motor, 3/4 HP ALL 060 208-/3 060915001 High Static Motor, 3/4 HP ALL 060 060915002 High Static Motor, 3/4 HP ALL 060 060915003 High Static Motor, 3/4 HP ALL 060 060915004 Fan & Housing Assembly Blower Housing & Wheel ALL 060 N/A 060699605 Blower Housing & Wheel, High Static Assy ALL 060 N/A 060899501 Wheel- Blower ALL 060 N/A 802000039 Wheel- Blower, High Static Assy ALL 060 N/A 060899201 Sensor Air & Water Temp Sensor ALL 060 N/A 106110801 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call 1-800-37PARTS 552360 Rev. B 06/2015 CPL Page 2 of 2