Finned Tube Air Heaters Type WD/GG (RVS)

Similar documents
Explosion-proof Immersion Heater Type D-8660

Fan Heaters Type VLEx

Element: Stainless steel (encapsulated) resistance wire. Fresh-Air-Fan 2 capacities. Standing model IP24

Sinus Jevi (Explosion-Proof) Condens Heaters

Fan Heaters Type TXI, WBK, WBG, Delta & VLE

CYLINDRICAL CASED AXIAL FLOW FANS. Cylindrical cased axial flow fans TCBB. Corrosion resistance. Impeller dynamically balanced.

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

ExPolar Heating System

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Air Heating: Portable... 3 Stationary mounting... 6 Gate/door (air curtains)... 8

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

High bay LED lighting fixture

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Performance Data. curus Component Recognized; File No. E IP 20

EN54-5, ATEX and IECEx approved Highly durable Automatic reset after cooling Range of alarm temperatures

Operating Instructions

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

Ex Long & Short stroke LPI POSITION TRANSMITTER MKII For linear position measurement in compressors

Operating Manual Distribution box

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

CCAC. Ex d. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Choice of 5 sizes - IP66. Stainless steel bolts.

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

Screw plug immersion heaters

Indoor/outdoor resistance thermometer Model TR60

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Technical Data. General specifications. Rated operating distance s n 5 mm

Flange immersion heaters

Exp, pressurized systems

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

ATEX - ATmosphere EXplosive

INSTRUCTION MANUAL (ATEX / IECEx)

OPERATIONS MANUAL. Hotplate Stirrer/Hotplate/Magnetic Stirrer Model HTS-1003/HTP-1002/MGS Certified

Specialty Products SPECIALTY PRODUCTS. Description. Camera Housing. VCB series Video Camera Housings 548. Specialty Products

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Manual Power relay SR853

Dräger Polytron 5100 EC Detection of toxic gases and vapors

INSTRUCTION MANUAL (ATEX / IECEx)

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

GAS DETECTOR ST400EC PART.NO

GENERAL OVERVIEW ELECTRIC HEATERS - EXCHANGERS - PACKAGES ELECTRIC HEATING SOLUTIONS ELECTRIC HEATERS EXCHANGERS PACKAGES

products 22 º C Ventilation Air Conditioning Refrigeration Unit heaters Inside PROVIDED BY HEINEN & HOPMAN

Rod probe 11961Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

Tel: +44(0) Fax: +44(0) /17 LGM Products Ltd. Web: ISO 9001:2015 certified

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

Hazardous Area Portable Fan Heater The Bulldog

OPERA MORE. Use. Range. Drycoolers Air-cooled condensers. for LESS. Capacity: up to 1100 kw. Water misting. Free cooling

OPERATING INSTRUCTIONS. HELIOS SAFE INDUSTRY ATEX 1500 Watt COD. EHSAFE Watt COD. EHSAFE20

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

TLS 600. Installation and Operation Manual. English Pages CEDES AG is certified according to ISO 9001: V 1.0.

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

THERMASREG TR 040 THERMASREG TR 060

Audible warning devices for external alarm

FE1 Explosion-Proof Electric Air Heaters

Product manual reducers, adapters, plugs etc. INDEX ELEKTRO BV Harregatplein VP Zuidland Netherlands

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 236

Temperature Measurement Transmitters for field mounting

3F Linda Inox 1x.. T8 HF ATEX II 3D T85 C IP65

OPTIBAR DP 7060 Supplementary Instructions

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

FOR PERFECT THERMAL MANAGEMENT WORLDWIDE

EU Declaration of Conformity EMC Directive 2014/30/EU, ATEX Directive 2014/34/EU, PED Directive 2014/68/EU No: MMI SE

Flameproof Manual Call Points Series MCP

SOLUZIONI PER ATMOSFERA ESPLOSIVA

Dräger Polytron 8100 EC Detection of toxic gases and vapors

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

Instruction Manual heater SH for SD dry cabinets

HEATXL RVS. Electric Infrared Heater

EU DECLARATION OF CONFORMITY

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

TUNNEL FANS STANDARD AND HOT SMOKE

Hazardous Location Heaters. Thermostat INSTRUCTION MANUAL

A2S s Company Profile

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

ATEX JEVI A/S ISO 9001 A12295 EXPLOSION PROOF ELECTRICAL HEATERS FOR INDUSTRIAL AND OFFSHORE APPLICATIONS

Micro and Mini Torch. Zones: 0, 1, 2, 20, 21 and 22. Product Overview. Features & Benefits. Certifications

Manual Isolating Barrier D461 (Revision 05)

IECEx Certificate of Conformity

USER MANUAL FOR EXPLOSION PROTECTED FLUORESCENT LIGHT FITTING type PSF 218

(German speaking trainers with English written slides)

Magnetic-Inductive Flow Velocity Sensor PIT. Installation and Operating Instructions

Gas cylinder scale Model GCS-1

Enclosure Heaters. Zone 1, Zone 2 & Safe Area

Main switch current K: with main switch (optional)

Type CODE Speed Heating Cooling

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Smart encoders & actuators

SPDT contacts: C/NO/NC. Contact Rating 16(4)A 250Vca. 7A1-1R306-00A A1-6R306-00A A A A A 10 90

Hazardous Area Portable Fan Heater The Bulldog

Transcription:

Finned Tube Air Heaters Type WD/GG (RVS) Our WD-H finned-tube heaters are designed for industrial use in drying rooms, engine rooms, pumping houses, elevator shafts, as protection from frost, etc. The heater does not require further protection. Liquids Gasses Solids Spaces Resistors Sinus-Jevi Electric Heating B.V. Aambeeld 19 1671 NT Medemblik +31 (0) 227 549 100 www.sinusjevi.com

Our WD-H finned-tube heaters are designed for industrial application. Because of their high level of reliability, they are especially suitable for all heating applications at an ambient temperature of up to 60 C. Due to the fact that their construction is in accordance with IP65, they are also suitable for damp areas. The heaters must be installed by skilled personnel. Because of the high surface temperature, they are not suitable for rooms containing inflammable materials and in areas with a possible risk of explosion. The heater is composed of ceramic centre formers, in wich a glow spiral is encased, in a 1- or 3-phase construction. The connection is robust and can substain high temperatures. It is possible to insert a second cable gland into the connection box, this will allow for the connection with a room thermostat. A room thermostat (IP30; 0-30 C) may also be placed on the lid of the connection box (in a dry environment). CONSTRUCTION The finned-tube air heaters consist of a 42-mm-diameter round steel tube, with rolled-in steel fins. The rolling-in process ensures the best possible heat transfer by the fins to the environment. The finned-tube heaters are spray-proof as per IP65. The appliance meets the CE directives. Connection is by means of a plastic cable gland (PG16) with pull relief. Finish: Grey epoxy-coating. The GG-H is identical to the WD-H, but with a galvanised surface. The Z addition indicates sand-filled (shock-proof) APPLICATION For industrial use in drying rooms, engine rooms, pumping houses, elevator shafts, as protection from frost, etc. As a high-level heater in heating coves, waiting rooms, workshops, service areas, etc. [out of hand s reach, EN 60335-2-30 (e.g. h=1.8 m)]. STANDARD VOLTAGES 230 Volt AC 1-phase. Different voltages and outputs can be delivered upon request. We can also deliver explosion-proof finned tube heaters. In accordance with the following EU directives: Low-voltage directive EMC directive A CE statement is supplied with the delivery. 2

Our WD-L finned-tube air heaters are designed for application in the home, the office or in industry. Because of the overheating protection and the low surface temperature, they are especially suitable for all heating applications at an ambient temperature of up to 30 C. Due to the fact that the construction is in accordance with IP65, they are also suitable for damp places. Because of the low surface temperature, they are also suitable for damp places. Because of the low surface temperature, they are safe to use in places of easy access. The heaters are composed of an enclosed stainless steel tubular element, in which a glow-spiral is encased in a 1-phase construction. The connection is simple. It is possible to insert a second cable gland into the connection box. This will allow for the connection of an external room thermostat. A room thermostat (IP 30: 0-30 C) may also be placed on the lid of the box (in a dry environment). CONSTRUCTION The finned-tube air heaters consist of a 42-mm-diameter steel tube, with rolled-in steel fins. The rolling-in process ensures the best possible heat transfer by the fins to the environment. The finned-tube air heaters are spray-proof as per IP65. The appliance meets with the CE directives. Connection is by means of a plastic cable gland (PG16) with pull relief. Finish: Grey epoxy-coating. The GG-L is identical to the WD-L, but with a galvanised surface. APPLICATION For industrial use in drying rooms, engine rooms, pumping houses, elevator shafts, as protection from frost, etc. As a low-level heater for all applications, such as waiting rooms, workshops, warehouses, coach-building works, etc. (EN 60335-2-30). The WD-L does not require further protection. STANDARD VOLTAGES 230 Volt AC 1-phase. Different voltages and outputs can be deliverd upon request. We can also deliver explosion-proof finned tube heaters. In accordance with the following EU directives: Low-voltage directive EMC directive A CE statement is supplied with the delivery. 3

Type Power Voltage Length (A) Mounting (B) Support-support (C) Weight Article number WD-H 250 250 Watt 230 Volt 305 mm 223 mm 255 mm 2.8 kg A020 310 250 WD-H 500 500 Watt 230 Volt 555 mm 473 mm 500 mm 4.6 kg A020 310 500 WD-H 1000 1000 Watt 230 Volt 1055 mm 973 mm 1000 mm 7.8 kg A020 311 000 WD-H 1500 1500 Watt 230 Volt 1555 mm 1473 mm 1500 mm 11.4 kg A020 311 500 WD-H 2000 2000 Watt 230 Volt 2055 mm 1973 mm 2000 mm 14.6 kg A020 312 000 GG-H 250 250 Watt 230 Volt 305 mm 223 mm 255 mm 2.8 kg A020 510 250 GG-H 500 500 Watt 230 Volt 555 mm 473 mm 500 mm 4.6 kg A020 510 500 GG-H 1000 1000 Watt 230 Volt 1055 mm 973 mm 1000 mm 7.8 kg A020 511 000 GG-H 1500 1500 Watt 230 Volt 1555 mm 1473 mm 1500 mm 11.4 kg A020 511 500 GG-H 2000 2000 Watt 230 Volt 2055 mm 1973 mm 2000 mm 14.6 kg A020 512 000 WD-L 500 300 Watt 230 Volt 555 mm 473 mm 500 mm 4.6 kg A020 310 300 WD-L 1000 600 Watt 230 Volt 1055 mm 973 mm 1000 mm 7.8 kg A020 310 600 WD-L 1500 900 Watt 230 Volt 1555 mm 1473 mm 1973 mm 11.4 kg A020 310 900 WD-L 2000 1250 Watt 230 Volt 2055 mm 1973 mm 2000 mm 14.6 kg A020 311 250 GG-L 500 300 Watt 230 Volt 555 mm 473 mm 500 mm 4.6 kg A020 510 300 GG-L 1000 600 Watt 230 Volt 1055 mm 973 mm 1000 mm 7.8 kg A020 510 600 GG-L 1500 900 Watt 230 Volt 1555 mm 1473 mm 1500 mm 11.4 kg A020 510 900 GG-L 2000 1250 Watt 230 Volt 2055 mm 1973 mm 2000 mm 14.6 kg A020 511 250 WD-Z 250 250 Watt 230 Volt 305 mm 223 mm 255 mm 3.2 kg A020 410 250 WD-Z 500 500 Watt 230 Volt 555 mm 473 mm 500 mm 5.2 kg A020 410 500 WD-Z 1000 1000 Watt 230 Volt 1055 mm 973 mm 1000 mm 9.4 kg A020 411 000 WD-Z 1500 1500 Watt 230 Volt 1555 mm 1473 mm 1500 mm 13.0 kg A020 411 500 WD-Z 2000 2000 Watt 230 Volt 2055 mm 1973 mm 2000 mm 17.0 kg A020 412 000 GG-Z 250 250 Watt 230 Volt 305 mm 223 mm 255 mm 3.2 kg A020 610 250 GG-Z 500 500 Watt 230 Volt 555 mm 473 mm 500 mm 5.2 kg A020 610 500 GG-Z 1000 1000 Watt 230 Volt 1055 mm 973 mm 1000 mm 9.4 kg A020 611 000 GG-Z 1500 1500 Watt 230 Volt 1555 mm 1473 mm 1500 mm 13.0 kg A020 611 500 GG-Z 2000 2000 Watt 230 Volt 2055 mm 1973 mm 2000 mm 17.0 kg A020 612 000 Built-up thermostat A020 200 001 The types above are also available with different power and voltage. 4

Stainless steel finned tube heaters are designed for industrial application. The heaters are suitable for use in corrosive areas such as: filling stations, water purification installations or storage areas. The fin material is made of stainless steel (AISI 409). Proofing IP66/IP67. Type TR is supplied with built-up thermostat, adjustable between +5 C to +30 C. Type ST is suplied with built-up step-controller: 1/3, 1/2 and full power. WD-H RVS TR (incl. thermostat) 118 WD-H RVS (excl. thermostat) 184 66 Ø7 V 115 145 L 5

Type Power Voltage Length (L) * Also available in 400 Volts Options for finned tube heaters type WD-H RVS Support-support (V) Article number WD-H RVS 250 250 Watt 230 Volt 350 mm 230 mm A021 310 250 WD-H RVS 500 500 Watt 230 Volt 500 mm 365 mm A021 310 500 WD-H RVS 1000 1000 Watt 230 Volt* 700 mm 565 mm A021 311 000 WD-H RVS 1500 1500 Watt 230 Volt* 900 mm 765 mm A021 311 500 WD-H RVS 2000 2000 Watt 230 Volt* 1100 mm 965 mm A021 312 000 WD-H RVS 3000 3000 Watt 230 Volt* 1500 mm 1365 mm A021 313 000 WD-H RVS TR 250 250 Watt 230 Volt 350 mm 230 mm A021 310 250T WD-H RVS TR 500 500 Watt 230 Volt 500 mm 365 mm A021 310 500T WD-H RVS TR 1000 1000 Watt 230 Volt 700 mm 565 mm A021 311 000T WD-H RVS TR 1500 1500 Watt 230 Volt 900 mm 765 mm A021 311 500T WD-H RVS TR 2000 2000 Watt 230 Volt 1100 mm 965 mm A021 312 000T WD-H RVS TR 3000 3000 Watt 230 Volt 1500 mm 1365 mm A021 313 000T WD-H RVS ST 1000 1000 Watt 230 Volt 700 mm 565 mm A021 311 001 WD-H RVS ST 1500 1500 Watt 230 Volt 900 mm 765 mm A021 315 001 WD-H RVS ST 2000 2000 Watt 230 Volt 1100 mm 965 mm A021 312 001 WD-H RVS ST 3000 3000 Watt 230 Volt 1500 mm 1365 mm A021 313 001 WD-L RVS 400 400 Watt 230 Volt 1100 mm 965 mm A021 310 402 WD-L RVS 600 600 Watt 230 Volt 1500 mm 1365 mm A021 310 602 WD-L RVS 800 800 Watt 230 Volt 1900 mm 1765 mm A021 310 802 WD-L RVS 1000 1000 Watt 230 Volt 2300 mm 2165 mm A021 311 002 WD-L RVS 1200 1200 Watt 230 Volt 2700 mm 2565 mm A021 311 202 WD-L RVS TR 400 400 Watt 230 Volt 1100 mm 965 mm A021 310 402T WD-L RVS TR 600 600 Watt 230 Volt 1500 mm 1365 mm A021 310 602T WD-L RVS TR 800 800 Watt 230 Volt 1900 mm 1765 mm A021 310 802T WD-L RVS TR 1000 1000 Watt 230 Volt 2300 mm 2165 mm A021 311 002T WD-L RVS TR 1200 1200 Watt 230 Volt 2700 mm 2565 mm A021 311 202T Protection grid of aluminium perforated plate Type Suitable for: Article number BS 500 WD-H RVS TR/ST 500 A021 000 500 BS 1000 WD-H RVS TR/ST 1000 A021 001 000 BS 1500 WD-H RVS TR/ST 1500 A021 001 500 BS 2000 WD-H RVS TR/ST 2000 A021 002 000 BS 3000 WD-H RVS TR/ST 3000 A021 003 000 6

Sinus is one of the pioneers in the field of explosion proof heating equipment, today we are still operating at the forefront. We manufacture according to ATEX as well as IECEx and EAC directives. For the production of Ex-proof equipment a PQAN (Product Quality Assurance Notification) is issued by TUV-Nord. Our ISO-9001 and ISO-14001 systems are also monitored by this organisation. A02.1102E 03-18 Sinus-Jevi Electric Heating B.V. Aambeeld 19 1671 NT Medemblik +31 (0) 227 549 100 www.sinusjevi.com