Replacement Parts List 0570900 Revision F 09/06 McQuay Large Vertical Water Source Heat Pump LGP, LHP, LWP 07-7 Vintage C Last Manufactured: 994 To find your Daikin Applied parts distributor, call -800-77-787 or visit www.daikinapplied.com
Contents Parts List Revision History... Nomenclature Model... 4 Serial...5 Catalog...5 Refrigeration Circuit Models 7 thru...6-7 Models 5 thru 7...8-0 Blower Section Diagram... Model 7 thru Horizontal Discharge... - Top Front & Rear Discharge...-4 Model 5 thru 7 Horizontal Discharge...5-6 Top Front & Rear Discharge...7-8 Control Box Models 07 thru...9 Models 5 thru 7...0, Panels Models 07 thru... Models 5 thru 7... Field Installed Accessories Thermostats & Subbases... Thermostat Accessories...4 Miscellaneous Accessories...4 Control Accessories...5 Loop Water Control (LWC) Panel & Accessories...6 System Savers & Accessories - All Units...7 Critical Parts List Models 07 thru...cpl Models 5 thru 7...CPL WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page
Parts List Revision History Rev. Date Description A 6/98 Updated to OnLine format. Added Revision History page. Changes made to: Page 8 - Added Condenser Coil (Bub.#) descriptions. Corrected Condenser Coil info for unit size 0. Page - Corrected Compressor (Bub.#) information for size 7, &. Page 9 - Added footnotes that were missing. B 9/00 Page -Bub #-Compr. Ckt #, size 7; 575V is now pn 00076 & 80V is now 0007. C 0/00 Pages re-numbered. Page - Sheave pn 0069 changed to 009. D 8/ Changed from PM6.5 to CS6.0. Format updated. Page 8- Bub 7, Delete No & No. E 06/6 Rebrand Daikin. Remove all p/n updates after 994. Change all drawings from tif to psd format. Page 7- Change Reversing Valve p/n 067870 to 067900. & p/n 067900 to 067870. CPL - CPL- Change to Daikin format. F 09/6 Page 4- Delete serial number /999 to present. Pages 6-7 Correct part numbering. CPL & CPL- Update revision. Daikin Applied, 600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN 55440 (76) 55-50 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page
Nomenclature Model LHP - 5 C - M - T Model Type LHP = Large Vertical Water Source Heat Pump LGP = Large Vertical Cooling Only LWP = Large Vertical Extended Range Unit Unit Size 07 = 76,000 Btu/hr Cooling 0 = 07,000 Btu/hr Cooling = 0,000 Btu/hr Cooling 5 = 78,000 Btu/hr Cooling 0 = 4,000 Btu/hr Cooling = 40,000 Btu/hr Cooling 5 = 65,000 Btu/hr Cooling 7 = 95,000 Btu/hr Cooling Voltage prior to /94 K = D = P = L = G = after /94 D = L = T = W = Q = Nomenclature after /94 Design Vintage Serial 7 T A 00000 00 Plant Identification 7 = Auburn Engineering Revision Serial Year Manufactured Q = 985 R = 986 S = 987 T = 988 U = 989 V = 990 W = 99 X = 99 Y = 99 Z = 994 Month Manufactured A = January G = July B = February H = August C = March J = September D = April K = October E = May L = November F = June M = December WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 4
Catalog Nomenclature D P A K M R A S Digits & Unit Type SELECTION DP DG DW DESCRIPTION Heat pump unit Cooling only unit Extended range unit SELECTION S Digit 8 Packaging DESCRIPTION Each unit strapped to wooden skid & covered with plastic Digit Piping hand & condenser coil SELECTION PIPING CONDENSER UNIT SIZE A RH SS/C 07 B LH SS/C 07 L RH S/C-N 07 M LH S/C-N 07 C RH SS/C 0 D LH SS/C 0 N RH S/C-N 0 P LH S/C-N 0 E RH SS/C F LH SS/C R RH S/C-N S LH S/C-N RH SS/C 5 LH SS/C 5 RH S/C-N 5 4 LH S/C-N 5 G RH SS/C 0 H LH SS/C 0 T RH S/C-N 0 U LH S/C-N 0 Q RH SS/C V LH SS/C W RH S/C-N Y LH S/C-N J RH SS/C 5 K LH SS/C 5 9 RH S/C-N 5 Z LH S/C-N 5 5 RH SS/C 7 6 LH SS/C 7 7 RH S/C-N 7 8 LH S/C-N 7 Note: RH Denotes right hand LH Denotes left hand SS/C Denotes Standard Steel/Copper S/C-N Denotes Optional Steel/Cupro-Nickel Digit 4 Voltage SELECTION VOLTAGE K D P L G SELECTION R F H Digit 7 Fan Motor & Drive SELECTION FAN MOTOR UNIT SIZE SIZE (HP) A.5* 07 B.0 07 C.0 07 A.5* 0 B.0 0 C.0 0 A.0* B.0 C 5.0 B.0* 5 C 5.0 5 D 7.5 5 A.0* 0 B 5.0 0 C 7.5 0 A 5.0* B 7.5 A 5.0* 5 B 7.5 5 C 0.0 5 B 7.5* 7 C 0.0 7 * Denotes standard size Digit 6 Discharge Air Arrangement DESCRIPTION Top rear discharge Top front discharge Rear horizontal disacharge Digit 5 Control Box Location SELECTION DESCRIPTION M Mark IV Front - Same side as return air N Controls Rear - Opposite side from return air Example: Catalog DPAKMRAS is a 08 volt, 60 Hz, Phase 76,000 BTUH cooling heat pump unit with right hand piping and standard steel/copper condenser. The unit is equipped with Mark IV controls with the control box located in front and on the same side as the return air, which is top rear discharge. The fan motor is a.5 HP motor, which is standard size for the 07 unit. Each unit is strapped to a wooden pallet and covered with plastic for shipping. WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 5
Refrigeration Circuit Models 0 & Heat Pump Shown 8 4 6 9 5 0 7 07 0 N/S Compressor 800096 Compressor 80009 Compressor 800095 Compressor 80008 Compressor 800075 Compressor 800079 Compressor 80008 Compressor 800076 Compressor 800080 N/S Grommet 800006 4 4 4 4 4 N/S Sleeve 044074900 4 4 4 4 4 N/S Compressor Mounting Plate 85000869 N/S Mounting Components 0668080 Condenser Coil Copper Inner Tube 80004 Condenser Coil Cupro-Nickel Inner Tube 800047 Condenser Coil Copper Inner Tube 064460K Condenser Coil Cupro-Nickel Inner Tube 064460K Condenser Coil Copper Inner Tube 064460K Condenser Coil Cupro-Nickel Inner Tube 0644604K WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 6
Refrigeration Circuit 07 0 Evaporator Coil 06089460 Evaporator Coil 80004 4 Expansion Valve 80066 5 Bleed Cap Tube 85000977 5 Bleed Cap Tube 8500085 6 Reversing Valve 067870 6 Reversing Valve 4 067900 N/S Solenoid, Reversing Valve 04760005 N/S Solenoid, Reversing Valve 04760005 N/S Solenoid, Reversing Valve 5 0665490 N/S Solenoid, Reversing Valve 6 0665490 7 Base, Valve 800640 8 High Pressure Switch 800058 9 Low Pressure Switch until 4/9 06060550 4/9 & later 05679740 0 Thermistor 80067 Fusible Plug 800504 Sight Glass 80064 Denotes used on Units with serial number Eng. revision level 00 or 0 Denotes used on Units with serial number Eng. revision level 00, 0 or 0 If serial number Eng. revision level is 00 or 0, must also replace solenoid coil with part number 665490 4 If serial number Eng. revision level is 00, 0 or 0, must also replace solenoid coil with part no. 665490 5 Use on Units with serial number Engineering revision level 0 and above 6 Use on Units with serial number Engineering revision level 0 and above WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 7
Refrigeration Circuit 4 7 EXPANSION VALVE 7 EXPANSION VALVE 4 CONDENSER NO. CONDENSER NO. 8* 0 * REVERSING VALVE NO. 8 REVERSING VALVE NO. WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 8
Refrigeration Circuit 5 0 5 7 Compressor- Circuit # 80008 Compressor- Circuit # 800075 Compressor- Circuit # 800079 Compressor- Circuit # 80008 Compressor- Circuit # 800076 Compressor- Circuit # 800080 Compressor- Circuit # 800077 Compressor- Circuit # 80007 Compressor- Circuit # 800076 N/S Mounting Plate 850009 N/S Mounting Plate 850047 N/S Compressor Mtg. Assy 0668080 Compressor- Circuit # 800096 Compressor- Circuit # 80009 Compressor- Circuit # 800095 Compressor- Circuit # 80008 Compressor- Circuit # 800075 Compressor- Circuit # 800079 Compressor- Circuit # 80008 Compressor- Circuit # 800076 Compressor- Circuit # 800080 Compressor- Circuit # 800077 Compressor- Circuit # 80007 Compressor- Circuit # 800076 N/S Mounting Plate 850080 N/S Grommet, Compressor Mtg. 800006 4 4 4 4 4 N/S Sleeve, Compressor Mtg. 044074900 4 4 4 4 4 N/S Compressor Mtg. Assy 0668080 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 9
Refrigeration Circuit 5 0 5 7 Cond Coil Copper 80004 Cond Coil Copper 064460K Cond Coil Copper 064460K Cond Coil Cupro-Nickel 800047 Cond Coil Cupro-Nickel 064460K Cond Coil Cupro-Nickel 0644604K 4 Evaporator Coil 800044 4 Evaporator Coil 800045 N/S Bleed Capilliary Cir. # 85000977 N/S Bleed Capilliary Cir. # 850009774 7 Expansion Valve Cir. # & # 80066 8 Reversing Valve Cir. # 067900 8 Reversing Valve Cir. # 067870 8 Reversing Valve 4 Cir. # 067900 8 Reversing Valve Cir. # 067870 N/S Solenoid, Reversing Valve 04760005 N/S Solenoid, Reversing Valve 067900 N/S Solenoid, Reversing Valve 5 0665490 N/S Solenoid, Reversing Valve 6 0665490 0 Base Valve 800640 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 High Pressure Switch 800058 High Pressure Switch 06060550 N/S Thermistor 80067 Fusible Plug 800504 4 Sight Glass 80064 K Denotes kit Denotes used on Units with serial number Eng. revision level 00 or 0 Denotes used on Units with serial number Eng. revision level 00, 0 or 0 If serial number Eng. revision level is 00 or 0, must also replace solenoid coil with part number 665490 4 If serial number Eng. revision level is 00, 0 or 0, must also replace solenoid coil with part no. 665490 5 Use on Units with serial number Engineering revision level 0 and above 6 Use on Units with serial number Engineering revision level 0 and above WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 0
Blower Section Horizontal Discharge Horizontal shown 0 7 8 6 9 4 5 Top Panel w/o Insulation 8500794 N/S Top Extension Panel w/o Insulation 85000897 Blower Housing 800000 Bearing Bracket 80004 4 Blower Shaft 80007 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 5 Key 800047 N/S Bearing 80006 6 Motor.5 HP 04975000 6 Motor.5 HP 800485 6 Motor HP 80048 6 Motor HP 80048 6 Motor HP 80048 6 Motor HP 07859700 6 Motor HP 800485 6 Motor 5 HP 005000 6 Motor 5 HP 800487 6 Motor 5 HP 800488 Includes housing, wheel & cutoff 07 0 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page
Blower Section Horizontal Discharge N/S Overload Heater 80007986 N/S Overload Heater 80007987 N/S Overload Heater 80007988 N/S Overload Heater 4 80007989 N/S Overload Heater 4 80007990 N/S Overload Heater 4 8000799 N/S Overload Heater 4 8000799 N/S Overload Heater 5 8000798 N/S Overload Heater 5 80007994 N/S Overload Heater 5 80007996 N/S Overload Heater 5 8000799 7 Adjustible Sheave- Groove 095400 7 Adjustible Sheave- Groove 80009 7 Adjustible Sheave- Groove 00600 7 Adjustible Sheave- Groove 4 00088700 7 Adjustible Sheave- Groove 4 80040 7 Adjustible Sheave- Groove 5 80040 8 Fixed Sheave- Groove 80009 8 Fixed Sheave- Groove,4 8008 8 Fixed Sheave- Groove,4 8008 8 Fixed Sheave- Groove 80009 8 Fixed Sheave- Groove 4 8008 8 Fixed Sheave- Groove 5 80000 9 Belt - A 80005 9 Belt - A 8009 9 Belt - B 80068 9 Belt - A 80005 9 Belt - B 4 80068 9 Belt - A 4 80070 9 Belt - B 4 0607550 9 Belt - B 5 80069 0 Motor Mount 8500658 Adjusting Bracket 850078 Includes housing, wheel & cutoff Denotes.5 HP motor Denotes HP motor 4 Denotes HP motor 5 Denotes 5 HP motor 07 0 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page
Blower Section Top Front & Top Rear Discharge Top Panel w/o Insulation 85000884 Includes housing, wheel & cutoff Denotes.5 HP motor Denotes HP motor 4 Denotes HP motor 5 Denotes 5 HP motor 07 0 N/S Top Extension Panel w/o Insulation 85000897 Blower Housing 800000 Bearing Bracket 80004 N/S Blower Hanger Bracket 8500096 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Blower Shaft 80007 5 Key 800047 N/S Bearing 80006 6 Motor.5 HP 04975000 6 Motor.5 HP 800485 6 Motor HP 80048 6 Motor HP 80048 6 Motor HP 80048 6 Motor HP 800484 6 Motor HP 800485 6 Motor 5 HP 800486 6 Motor 5 HP 800487 6 Motor 5 HP 800488 N/S Overload Heater 80007986 N/S Overload Heater 80007987 N/S Overload Heater 80007988 N/S Overload Heater 4 80007989 N/S Overload Heater 4 80007990 N/S Overload Heater 4 8000799 N/S Overload Heater 4 8000799 N/S Overload Heater 5 8000798 N/S Overload Heater 5 80007994 N/S Overload Heater 5 80007996 N/S Overload Heater 5 8000799 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page
Blower Section Top Front & Top Rear Discharge 7 Adjustible Sheave- Groove 800045 7 Adjustible Sheave- Groove 80009 7 Adjustible Sheave- Groove 800046 7 Adjustible Sheave- Groove 4 80006 7 Adjustible Sheave- Groove 4 80040 7 Adjustible Sheave- Groove 5 80040 8 Fixed Sheave- Groove 80009 8 Fixed Sheave- Groove,4 8008 8 Fixed Sheave- Groove 8008 8 Fixed Sheave- Groove 80009 8 Fixed Sheave- Groove 4 80000 8 Fixed Sheave- Groove 4 8008 8 Fixed Sheave- Groove 5 80000 9 Belt - A 8004 9 Belt - A 80049 9 Belt - B 800098 9 Belt - A 8004 9 Belt - B 4 8004 9 Belt - A 4 800088 9 Belt - B 5 80054 0 Motor Mount 8500658 Adjusting Bracket 85006505 N/S Rear Panel 8500658 Includes housing, wheel & cutoff Denotes.5 HP motor Denotes HP motor 4 Denotes HP motor 5 Denotes 5 HP motor 07 0 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 4
Blower Section Horizontal Discharge N/S Top Panel 8500868 N/S Blower Housing 800009 N/S Blower Housing Bracket 85008606 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Bearing Bracket 80004 N/S Bearing w/collar 800059 N/S Pillow Block Bearing 06660 N/S Blower Shaft 800058 N/S Key 800047 N/S Motor HP 80048 N/S Motor HP 800484 N/S Motor HP 800485 N/S Motor 5 HP 005000 N/S Motor 5 HP 800487 N/S Motor 5 HP 800488 N/S Motor 7.5 HP 05480 N/S Motor 7.5 HP 800490 N/S Motor 7.5 HP 80049 N/S Motor 0 HP 80049 N/S Motor 0 HP 800494 N/S Motor 0 HP 800495 N/S Overload Heater 80007989 N/S Overload Heater 80007990 N/S Overload Heater 8000799 N/S Overload Heater 8000799 N/S Overload Heater 8000799 N/S Overload Heater 80007994 N/S Overload Heater 80007986 N/S Overload Heater 8000798 N/S Overload Heater 80007996 N/S Overload Heater 4 80007989 N/S Overload Heater 4 80007995 N/S Overload Heater 5 80007997 N/S Overload Heater 5 80007998 N/S Overload Heater 5 80007989 Includes housing, wheel & cutoff Denotes HP motor Denotes 5 HP motor Denotes 7.5 HP motor Denotes 0 HP motor 5 0 5 7 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 5
Blower Section Horizontal Discharge N/S Adj. Sheave- Groove, 80006 N/S Adj. Sheave- Groove 80006 N/S Adj. Sheave- Groove 4 8007 N/S Adj. Sheave- Groove 5 00087500 N/S Fixed Sheave- Groove 8006 N/S Fixed Sheave- Groove 80007 N/S Fixed Sheave- Groove,4 8006 N/S Fixed Sheave- Groove 00048900 N/S Fixed Sheave- Groove 4 8006 N/S Fixed Sheave- Groove 4 8006 N/S Fixed Sheave- Groove 5 800075 N/S Bushing 80055 N/S Belt B 00047800 N/S Belt B 8007 N/S Belt B 80067 N/S Belt B 80046 N/S Belt B 4 80056 N/S Belt B 4 8006 N/S Belt B 5 80008 N/S Motor Mount 800078 N/S Motor Mount 80004 N/S Motor Mount 4 800077 N/S Motor Mount 5 800 Includes housing, wheel & cutoff Denotes HP motor Denotes 5 HP motor Denotes 7.5 HP motor Denotes 0 HP motor 5 0 5 7 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 6
Blower Section Top Front & Top Rear Discharge N/S Top Panel Top/FrontDischarge 8500860 N/S Blower Housing 800009 N/S Blower Hanger Bracket 85008606 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Bearing Bracket 80004 N/S Bearing w/collar 800059 N/S Pillow Block Bearing 06660 N/S Blower Shaft 800058 N/S Key 800047 N/S Motor HP 80048 N/S Motor HP 800484 N/S Motor HP 800485 N/S Motor 5 HP 005000 N/S Motor 5 HP 800487 N/S Motor 5 HP 800488 N/S Motor until 6/0 7.5 HP 054800 6/0 & later 7.5 HP 047440 N/S Motor 7.5 HP 800490 N/S Motor 7.5 HP 80049 N/S Motor 0 HP 80049 N/S Motor 0 HP 800494 N/S Motor 0 HP 800495 N/S Overload Heater 80007989 N/S Overload Heater 80007990 N/S Overload Heater 8000799 N/S Overload Heater 8000799 N/S Overload Heater 8000799 N/S Overload Heater 80007994 N/S Overload Heater 80007986 N/S Overload Heater 8000798 N/S Overload Heater 80007996 N/S Overload Heater 4 80007989 N/S Overload Heater 4 80007995 N/S Overload Heater 5 80007997 N/S Overload Heater 5 80007998 N/S Overload Heater 5 80007989 Includes housing, wheel & cutoff Denotes HP motor Denotes 5 HP motor Denotes 7.5 HP motor Denotes 0 HP motor 5 0 5 7 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 7
Blower Section Top Front & Top Rear Discharge 5 0 5 7 N/S Bushing,4 80055 N/S Bushing 80055 N/S Adj. Sheave- Groove, 80006 N/S Adj. Sheave- Groove 80006 N/S Adj. Sheave- Groove 4 8007 N/S Adj. Sheave- Groove 5 00087500 N/S Fixed Sheave- Groove 8006 N/S Fixed Sheave- Groove 80007 N/S Fixed Sheave- Groove,4 8006 N/S Fixed Sheave- Groove 00048900 N/S Fixed Sheave- Groove 4 8006 N/S Fixed Sheave- Groove 4 8006 N/S Fixed Sheave- Groove 5 800075 N/S Belt B 00047500 N/S Belt B 80064 N/S Belt B 00047800 N/S Belt B 80065 N/S Belt B 4 8006 N/S Belt B 4 80066 N/S Belt B 5 000884400 N/S Motor Mount 800078 N/S Motor Mount 800070 N/S Motor Mount 4 800077 N/S Motor Mount 5 800 N/S Back Panel 8500869 Includes housing, wheel & cutoff Denotes HP motor Denotes 5 HP motor Denotes 7.5 HP motor Denotes 0 HP motor WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 8
Control Box 5 4 * For extended range units 07 0 Control Board, Mark IV 06068805 Compressor Contactor, P 50A 80005879 Compressor Contactor, P 0A 80005 Fan Contactor, DPST 0A 80005096 Fan Contactor- P 0A 80005 Fan Starter P 0A - HP Motor 800055 Fan StarterP 0A - HP Motor 800055 4 Transformer- 08-40V/4V 50VA 060640 4 Transformer- 480V/4V 50VA 06067600 4 Transformer- 40-08V/4V 50VA 0606760 4 Transformer- 400V6.5V 48VA 8000590 5 Terminal Block 80007686 N/S Thermostat, Low Temp. Cut Out 06654060 N/S Thermostat, Low Temp. Cut Out * 06654060 N/S Flow Switch * 80069 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 9
Control Box 4 9 * 8 * PHANTOM IS 460V ARRANGEMENT 6 7 5 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 0
Control Box 5 0 5 7 Control Board, Mark IV 06068805 Comp. Cont. P 50A 80005879 Comp. Cont. P 0A 80005 Relay 8000509 4 Starter 800055 4 Starter 800055 5 Transformer 80005466 5 Transformer 80005465 5 Transformer 8000590 5 Transformer 0606760 5 Transformer 8000590 6 Transformer 06067600 6 Transformer 0606760 6 Transformer 8000590 7 Circuit Breaker 80007 8 Relay (Optional) # 9 Terminal Block 80007686 N/S Suppressor Assy 060740 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S TStat, Low Temp. Cut Out 06654060 N/S TStat, Low Temp. Cut Out* 06654060 N/S Flow Switch * 80069 # Denotes part number may vary depending on application ( Requires vendor number from part ) * Denotes for extended range units WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page
Panels 07 0 N/S Condensate Pan 85000888 N/S Compressor Access Panel 8500089 N/S Blower Access Panel 85000878 N/S Blower Cover 8500085 N/S Front/Rear Panel Assy- w/o Insulation 8500089 N/S Motor Access Panel 85000889 N/S Condensate Sensor Kit 8500060 5 0 5 7 N/S Condensate Pan 8500860 N/S Splash Pan 8500865 N/S Access Panel 8500864 N/S Blower Access Panel 8500860 N/S Blower Cover 8500085 N/S Lower Panel 8500099 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page
Field Installed Accessories Thermostats & Subbases DESCRIPTION PART NUMBER -Heat -- -Cool thermostats for single compressor units -- Not for LHP 5 & 0 Standard manual changeover thermostat & subbase. Honeywell T84C with no LED. Mounts vertical. System Heat-Off-Cool switch and fan On - Auto switch. Standard automatic changeover thermostat & subbase. Honeywell T874/Q674. LED for Service. Mounts horizontal. System Off-Auto switch and fan On-Auto switch. Thermostat Subbase 8000545 (Includes subbase) 0668660 06068480 Standard manual & auto changeover thermostat & subbase. Honeywell T874/Q674. LED for Service. Mounts horizontal. System Off-Heat-Auto-Cool switch and fan On-Auto switch. Deluxe automatic changeover thermostat & subbase with night setback & override. Honeywell T874/Q674. LED for Service. Mounts horizontal. Requires grounding of unit U terminal. Night setback bulb set o F below day heat setpoint. System Off-Auto switch and fan On-Auto-Override switch. Standard automatic changeover thermostat & subbase for operating two units. Honeywell T874/Q674. LED for Service. Mounts horizontal. System Off-Auto switch. Honeywell Chronotherm III programmable electronic thermostat & subbase ( stage heat, stage cool) Thermostat Subbase Thermostat Subbase Thermostat Subbase 0668660 06068490 06040 06060 066804406 06068470 06740 -Heat -- -Cool thermostats for dual compressor units -- LHP 5 thru 7 Standard automatic changeover thermostat & subbase. Honeywell T874D/Q674C. LED for Service. System On-Off switch & fan On-Auto switch. Deluxe automatic changeover thermostat & subbase with night setback & override. Honeywell T874/Q674 LED for Service. Mounts horizontally. Requires grounding of each Mark IV board U terminal. Night setback bulb set at o F below day heat setpoint to bring on both stages of heating. System Off-Auto switch & fan On-Auto-Override switch. Standard manual & auto changeover thermostat & subbase. Honeywell T874D/Q674E. LED for Service. System Off-Heat-Auto-Cool switch and fan On-Auto switch. Thermostat Subbase Thermostat Subbase Thermostat Subbase Honeywell Chronotherm III programmable electronic thermostat & subbase ( stage heat, stage cool) 0668660 06068480 06050 06060 0668660 06068490 06740 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page
Field Installed Accessories Thermostat Accessories DESCRIPTION Night setback thermostat. Honeywell T8. Mounts vertically. No LED. No switches. For applications requiring a separate NSB stat. Universal thermostat guard. Honeywell TG5A. Clear plastic with ring base, lock and keys. Deluxe locking cover for T8478/Q674 thermostats. Honeywell TG504A applies only to T8478/Q674 thermostats. Replaces standard thermostat cover. Includes cover, lock & keys *. Adapter plate for T874/Q674 thermostats. Allows for horizontal thermostat to be mounted on a vertical junction box. 7-Day timer clock (Not applicable to 50 cycle units). Includes spring carryover. Override timer -- hour normally closed -- timed open Override timer -- 6 hour normally closed -- timed open Programmable thermostat guard. Honeywell TG5A. Clear plastic with ring base, lock and keys. * Note: Do not use with Deluxe ACO stats & subbases: 06040, 06050 and 06060. PART NUMBER 8000580 06640660 06068450 8000767 8000576 8000577 8000578 06640670 Miscellaneous Accessories DESCRIPTION Standard supply or return hose. Rubber hose with one MPT & one MPT swivel fitting. Two required per unit. Standard condensate hose. Clear vinyl hose with FPT fitting. Trap not included -- by others. One required per unit. Fire rated supply or return hose. Steel braided hose with MPT x MPT swivel connections. Two required per unit. Fire rated condensate hose. Steel braided hose with MPT x MPT swivel connections. Trap not included -- by others. One required per unit. Ball vallve. Combination shutoff and balancing valve with memory stop. Return air duct collar. Attaches to filter frame & provides a collar allowing return duct connection. Filter rack. Replaces standard thick filter brackets. Does not include filters. Throwaway filters. Replacement for standard filters. Order in quantities (multiples) of Throwaway filters. For filter rack. Order in quantities (multiples) of. Vibration isolators. Rubber type with locating pin to fit in base panel. White Green /4 x /4 x / x / x x 0 /4 x 8 /4 x /4 x / x / x x 4 x 6 /4 FPT / FPT 4 per unit 6 per unit 4 per unit 6 per unit 4 per unit 6 per unit UNIT SIZE 7 -- 7 -- 5 -- 7 5 -- 7 7 -- 5 -- 7 7 -- 7 -- 5 -- 7 5 -- 7 7 -- 7 -- 7 -- 5 -- 7 7 -- 5 -- 7 7 -- 5 -- 7 7 -- 5 -- 7 7 -- 5 -- 7 7 -- 5 -- 7 PART NUMBER 066890 066890 066890 0668904 8005507 8005508 06690 06690 06099004 0609900 0669005 0669006 8006 800677 05900478 05900479 05900480 0590048 80008065 80008068 800087 8000808 0590075 059000960 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 4
Field Installed Accessories Control Accessories DESCRIPTION Auxiliary relay. 4 volt DC relay to be wired to low voltage terminal block to allow a set of SPDT pilot duty contacts to operate miscellaneous devices when the fan or compressor operates. Contacts rated at amps, 4 volts. Boilerless system kit. Includes electronics and sensor to lockout compressor operation at 50 o F to 60 o F EWT & provide SPNO contacts to a field supplied electric heater control system. Motorized valve. Includes valve/operator. Valve shuts water flow off for variable pumping. 00 psig maximum operating pressure. Requires control relay below. See note. Control relay for motorized valve. /4 FPT, Cv = 47 / FPT, Cv = 8 Note: Do not apply motorized valve accessory to LWP Extended Range Units. UNIT SIZE ALL 7 thru 7 thru 5 thru 7 ALL PART NUMBER 8000507 06550 06000 0600 0600 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 5
Loop Water Control (LWC) Panel & Accessories DESCRIPTION Loop water control panel 6 less modem. Provides 9 outputs selectable for heat rejection and heat addition stages and timeclock (maximum 6) schedules. Add installation kit(s) below. Loop water control panel 6 with modem. Same as above with the addition of a modem for remote communication. Add Monitor Software. Add installation kit(s) below. Requires PC modem below. Loop water control panel 4 less modem. Provides 7 outputs selectable for heat rejection and heat addition stages and timeclock (maximum 6) schedules. Add installation kit(s) below. Loop water control panel 4 with modem. Same as above with the addition of a modem for remote communication. Add Monitor Software. Add installation kit(s) below. Requires PC modem below. Heat pump loop installation kit. For control of the main water loop temperature. Includes immersion well, water temperature sensor, flow switch & outdoor air temperature sensor. Open tower loop installation kit. For control of the open tower condenser pumps. Includes flow switch, immersion well and water temperature sensor. Time schedule control relay. 4 VDC relay for control of the Mark IV U terminal. One per each time clock output which replaces the standard 4 VAC relays in the panel. Dry contact relay. For true dry contacts type relay. Replaces the standard 4 volt relays in the panel. Pump restart relay. For use on Mark IV units in conjunction with Loop Water controller, LWC, to restart circulating pump(s) when a compressor starts. One relay required for 00 units along with a -wire daisy chain loop between units. Additional immersion sensor. For monitoring additional water temperatures such as return water, storage, etc. Includes well and sensor. Remote alarm panel. For remote monitoring of the LWC panel status. Includes LED s, alarm horn and alarm silence switch. Monitor software. Provides interfacing of the LWC panel to an IBM compatible PC thru an RS- port with a direct connection or thru phone lines (remote). Requires 4M RAM, hard disk w/5mb free space, serial port, - / disk drive. VGA color monitor, VGA graphcs card, keyboard and printer. See note below. PART NUMBER 066005 066005 066005 0660054 05570 05570 0496560 0496560 064900 049760 055540 065850 Note: For remote communication thru phone lines, the PC requires a modem & LWC must be with a modem. WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 6
System Savers & Accessories - All Units Small Frame, Vertical Large Frame,.5 Degree Low Profile Large Frame, Vertical System Saver Purge Items No bracket available for size. DESCRIPTION / MPT, 4 -- 0 GPM /4 MPT, 0 -- 0 GPM MPT, 9 -- GPM /4 MPT, 8 -- 48 GPM / MPT, 45 -- 70 GPM MPT, 65 -- 08 GPM / MPT, 95 -- 55 GPM MPT, 48 -- 90 GPM Mounting Bracket (/ & /4 ) Mounting Bracket ( & / ) Mounting Bracket ( & / ) -- See 4 Flanged, 75 -- 550 GPM 6 Flanged, 480 -- 880 GPM 6 Flanged, 70 -- 00 Gpm 8 Flanged, 000 -- 670 GPM 4 Flanged, 75 -- 550 GPM 6 Flanged, 480 -- 880 GPM 6 Flanged, 70 -- 00 Gpm 8 Flanged, 000 -- 670 GPM Manual Purge Valve, Plastic (/4 ) Manual Purge Valve, Bronze (/4 ) Manual Purge Valve, Bronze ( ) Manual Purge Valve, Bronze ( /4 ) Bag Strainer Kit Replacement Bags (4) PART NUMBER 0640 0640 06404 06405 06406 06407 06408 06409 8005658 800556 800557 0640 0640 0640 06404 0640 0640 0640 06404 800555 8006098 800609 8006 800558 800559 WSHP; LGP,LHP,LWP 07-7 Vintage C Rev. F 09/6 RPL 05709 / Page 7
Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! McQuay Large Vertical WSHP LHP, LGP, LWP 07 - Vintage C Critical Components Unit Sizes Voltage Part Control Control Board, Mark IV ALL ALL 06068805 Compressor Compressor 07 08-800096 Compressor 07, 80009 Compressor 07 800095 Compressor 09 08-80008 Compressor 09, 800075 Compressor 09 800079 Compressor 08-80008 Compressor, 800076 Compressor 800080 Blower Motor Motor,.5HP 07, 0 08/0/ 04975000 Motor,.5HP 07, 0 04975000 Motor,.5HP 07, 0 800485 Motor, HP 07-80048 Motor, HP 07-0/, 80048 Motor, HP 07-80048 Motor, HP 07-80048 Motor, HP, Horizontal Discharge 07-0/, 07859700 Motor, HP, Top Dishcharge- Front & Rear 07-0/, 800484 Motor, HP 07-800485 Motor, 5HP, Horizontal Discharge 005000 Motor, 5HP, Top Dishcharge- Front & Rear 800486 Motor, 5HP 0/, 800487 Motor, 5HP 800488 Fan Housing and Wheel Blower Housing/Wheel/Cutoff Assy ALL N/A 800000 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call -800-7PARTS 5709 Rev. F 09/06 CPL Page of
Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! McQuay Large Vertical WSHP LHP, LGP, LWP 5-7 Vintage C Critical Components Unit Sizes Voltage Part Control Control Board, Mark IV ALL ALL 06068805 Compressor Compressor, Circuit # 5, 0 08-80008 Compressor, Circuit # 5, 0, 800075 Compressor, Circuit # 5, 0 800079 Compressor, Circuit #, 5 08-80008 Compressor, Circuit #, 5, 800076 Compressor, Circuit #, 5 800080 Compressor, Circuit # 7 08-800077 Compressor, Circuit # 7, 80007 Compressor, Circuit # 7 800076 Compressor, Circuit # 5 08-800096 Compressor, Circuit # 5, 80009 Compressor, Circuit # 5 800095 Compressor, Circuit # 0 08-80008 Compressor, Circuit # 0, 800075 Compressor, Circuit # 0 800079 Compressor, Circuit #, 5 08-80008 Compressor, Circuit #, 5, 800076 Compressor, Circuit #, 5 800080 Compressor, Circuit # 7 08-800077 Compressor, Circuit # 7, 80007 Compressor, Circuit # 7 800076 Blower Motor Motor, HP 5, 0 08/ 80048 Motor, HP 5, 0, 800484 Motor, HP 5, 0 800485 Motor, 5HP 5-005000 Motor, 5HP 5-5 0/, 800487 Motor, 5HP 5-5 800488 Motor, 7. 5HP 5-7 047440 Motor, 7.5HP 5-7 0/, 800490 Motor, 7.5HP 5-7 80049 Motor, 0HP 5, 7 80049 Motor, 0HP 5, 7 0/, 800494 Motor, 0HP 5, 7 800495 Fan Housing and Wheel Blower Housing/Wheel/Cutoff Assy ALL N/A 800009 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call -800-7PARTS 5709 Rev. F 09/06 CPL Page of