FH - GH FH - GH. Dehumidifiers for radiant cooling systems. Versions

Similar documents
FH - GH Dehumidifiers for radiant cooling systems

GHE Dehumidifiers for radiant cooling systems with heat recovery

G E N E R A L C ATA L O G Dehumidif ers

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

FHE. Dehumidifiers for radiant cooling systems with heat recovery. Display. Versions

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

LZT High efficiency air to water heat pumps with E.V.I. compressors

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

LZA High efficiency air to water heat pumps with HP compressor

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

LZT High efficiency air to water heat pumps with E.V.I. compressors

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

WHA WHA. Ground source water to water heat pumps A ++ A ++ Versions

LZT LZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. A + A + VERSIONS ACCESSORIES

STANDARD DEHUMIDIFIERS EH SERIES TECHNICAL MANUAL

WHA WHA. Ground source heat pumps OTHER VERSIONS ACCESSORIES

DEHUMIDIFIERS FOR SWIMMING POOL. International. ET INTERNATIONAL S.r.l. Via Circonvallazione Est, 32/R Castelfranco Veneto - TREVISO - ITALY

WSK WSK. Water to water chillers and heat pumps VERSIONS ACCESSORIES

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

WZH Ground source heat pumps

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

DOMESTIC DEHUMIDIFIERS FLIPPERDRY

LSN Series. Air cooled water chillers, heat pumps and motocondensing units with axial fans Capacities from 4 to 40 kw.

LDN Series. Trattamento dell aria SELECTION, INSTALLATION AND MAINTENANCE MANUAL

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

HYDRONIC RESIDENTIAL

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

Personalized comfort for offices and shopping malls RANGE OPERATING LIMITS

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

LVN Series. Trattamento dell aria SELECTION, INSTALLATION AND MAINTENANCE MANUAL

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

NEXT DL NEXT DL. rcgroupairconditioning

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Multi-pipe Units with Scroll Compressors. Model CMAA Cooling capacity kw Heating capacity kw

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

unico pf unico pf rcgroupairconditioning

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Industrial cooling solutions

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)


RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

TECHNICAL MANUAL FOR AIR-COOLED CONDENSING UNITS MTE

ROOFTOP PACKAGED AIR CONDITIONERS

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Air cooled industrial chillers

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

CHAPTER 6 CONDENSING UNITS

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

QTS SELECTION TECHNICAL BOOKLET

Models: A5ACV 30 CR A5ACV 55 CR A5ACV 75 CR A5ACV 100 CR A5ACV 135 CR A5ACV 210 CR A5ACV Air-Cooled Chiller (R410A Inverter Series)

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

PRODUCT OVERVIEW. Dehumidifiers

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

pyxis u pyxis ua NEW rcgroupairconditioning

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

next evo cw next evo cw rcgroupairconditioning

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

technical data Fan coil unit FWB small duct unit

Galletti Water chillers and heat pumps catalogue

Process glycol chillers

Blower-YEFB-020-3R-1maxVel

next p dw next p dw rcgroupairconditioning

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

Be sustainable while protecting your business

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

Split-system cooling units and heat pumps SERIES. Outdoor unit. Indoor unit OPERATING LIMITS. Inlet air conditions Cooling Heating.

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Transcription:

Dehumidifiers for radiant cooling systems FH GH 138 The dehumidifiers FH and GH series are high performance units, equipped with robust galvanised steel frame, properly designed to operate in combination with radiant cooling systems. The FH units have been designed for wall mounting installation while the GH series are suitable for false ceiling and ducted applications. ll units are provided with air filter, stainless steel drip tray and built-in microprocessor control. The units are also provided, standard, with pre and post cooling coil to enhance the performances and to control the air supply temperature. FH and GH units, anyway, can operate even without pre and post cooling coils, this option could be very useful in middle seasons when it is necessary to dry but the air conditioning system is not in operation. ll the units are fully assembled and wired in the factory, carefully evacuated and dried with after leak tests under pressure and they are charged with environmental friendly refrigerant gases. They are fully tested before shipment; the units are conform to European Directives and are individually marked with E label and onformity Declaration. Versions WZ Units supplied with double condenser (the first is an air condenser, the second is a water one) and of a logic which allows the dehumidification with neutrum air or with cooled air.

FH - FHWZ 25 25WZ Moisture removed (1) l/24h 20,1 20,1 ooling capacity (1) W --- 1250 Total power input (1) W 360 360 Max power input W 440 440 Max input current 2,7 2,7 Peak current 18,1 18,1 ir flow m 3 /h 250 250 Refrigerant R134a R134a Global warming potential (GWP) 1430 1430 Refrigerant charge Kg 0,2 0,6 Equivalent O2 charge t 0,36 0,89 Water flow l/h 150 150 Pressure drop kpa 8 7,8 Sound power (2) db() 45 45 Sound pressure (3) db() 37 37 Power supply V/Ph/Hz 230/1/50 230/1/50 GH - GHWZ 25 25WZ 50 50WZ 100 100WZ 200 200WZ Moisture removed (1) l/24h 20,1 20,1 48,5 48,5 87,2 87,2 164,0 164,0 ooling capacity (1) W --- 1250 --- 3500 --- 6000 --- 11300 Total power input (1) W 340 340 700 700 1450 1450 2450 2450 Max power input W 420 420 830 830 1690 1690 2890 2890 Max input current 2,7 2,7 5,0 5,0 8,1 8,1 14,4 14,4 Peak current 18,1 18,1 20,7 20,7 35,9 35,9 63,0 63,0 Water flow l/h 150 150 500 500 600 600 900 900 Pressure drop kpa 8,0 7,8 17,0 42,0 32,0 39,5 48,0 64,0 ir flow m 3 /h 250 250 600 600 1000 1000 1850 1850 vailable static pressure (max. speed) Pa 43 43 60 60 75 75 120 120 Refrigerant R134a R134a R407 R407 R407 R407 R407 R407 Global warming potential (GWP) 1430 1430 1774 1774 1774 1774 1774 1774 Refrigerant charge Kg 0,2 0,6 0,7 0,9 1,0 1,6 1,7 2,0 Equivalent O2 charge t 0,36 0,89 1,24 1,57 1,77 2,79 3,02 3,55 Sound power (2) db() 45 45 50 50 57 57 64 64 Sound pressure (3) db() 37 37 42 42 49 49 56 56 Power supply V/Ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 Performances are referred to the following conditions: (1)Room temperature 26 ; relative humidity 65% with cold water coil water inlet temp. 15. (3)Sound power level in accordance with ISO 9614. (2)Sound pressure level measured at 1 mt from the unit in free field conditions according to ISO 9614, minimum fan speed.(only for FH versions) www.hidros.eu 139

Frame ll units FH-GH series are made from hot-galvanised thick sheet metal, to ensure the best resistance against the corrosions. The frame is self-supporting with removable panels. The drip tray is present standard in all units and is made of plastic material for model 25 and in metal material for models 50-100-200. Microprocessor ll units FH-GH are supplied standard with microprocessor controls. The microprocessor controls the following functions: compressor timing, automatic defrost cycles and alarms. n appropriate LD display shows the operation mode of the unit, set point and alarms. 140 Refrigerant circuit The refrigerant circuit is made by using international primary brands components and according to ISO 97/23 concerning welding procedures. The refrigerant gas used in these units is R134a for the model 25 and R407 for the models 50-100-200. The refrigerant circuit includes: filter drier, capillary expansion device, Schrader valves for maintenance and control, pressure safety device (according to PED regulation). ompressor The compressor (for model 25) is alternative or rotative type (for models 50-100-200), equipped with crankcase heater and thermal overload protection by a klixon embedded in the motor winding. It s mounted on rubber vibration dampers to reduce the noise. ondenser and evaporator The condensers and evaporators are made of copper pipes and aluminium fins. The diameter of the copper pipes is 3/8 and the thickness of the aluminium fins is 0,1 mm. The tubes are mechanically expanded into the aluminium fins to improve the heat exchange factor. The geometry of these condensers guarantees a low air side pressure drop and then the use of low rotation (and low noise emission) fans. ll the units have a stainless steel drip tray. Besides this, each evaporator is supplied of a temperature probe used as automatic antifreeze probe. In all units WZ besides these exchangers, there is a third stainless steel INOX ISI 316 plate exchanger used us condenser in cooling modality, powered by the plant water. Pre and post water cooling coils The pre and post cold water coils are made of copper pipes and aluminium fins. The diameter of the copper pipes is 3/8 and the thickness of the aluminium fins is 0,1 mm. The tubes are mechanically expanded into the aluminium fins to improve the heat exchange factor. The pre-cooling coil is used to increase the dehumidification capacity of the unit, while the post-cooling coil is used to keep the outlet air temperature at the same inlet value. In WZ version only the pre cooled water coil is present. Fan The supply fan is centrifugal type, double inlet with forwards blades, dynamically and statically balanced and directly connected to a 3 speed fan motor. ir filter For the model GH 25-50 it s supplied standard with the unit and it s built in nylon. It can be removed for differential disposal, class G2, according to EN 779:2002. Regarding the model GH 100-GH 200 instead, it s made of filtering material in synthetic fibre without electrostatic charge. It can be removed for differential disposal, class G3, according to EN 779:2002 Electric box The electric switch board is made according to electromagnetic compatibility norms EE 73/23 and 89/336. The accessibility to the board is possible after removing the front panel of the unit. Ready for the connection to the power and to the consensus control, The terminal board is also supplied with voltage free contacts for remote ON-OFF. The terminal block is also built with a clean contact to allow the operation of single-mode ventilation, while the second for the cooling version (WZ). By closing the first contact, only the fan is abled to work, while the dehumidification is disabled. ontrol and protection devices ll units are supplied with the following control and protection devices: defrost thermostat, which signals to the microprocessor control that a defrost cycle is needed and controls its termination (only for GH100-100WZ and GH200-200WZ). Water temperature sensor, that signals to the microprocessor the eventual overcome of the hot water temperature set point in the pre and post water coils during operation. In this condition the compressor is disconnected while the fan always run and, when the water temperature returns within the operation limits, restarts the compressor. The water sensor stops the compressor when the water temperature is above 35. The eventual use of the dehumidifier as heating device during winter season requires an additional remote thermostat with seasonal change over (not supplied). In the all WZ version, it s also supplied a high pressure switch which disable the unit operation when the limit is overcome. Test ll the units are fully assembled and wired at the factory, carefully evacuated and dried after leak tests under pressure and then charged with ecologic refrigerant. They are all fully operational tested before shipment. They all conform to European Directives and are individually marked with the E label and provided with onformity Declaration.

FH - FHWZ 25 25WZ Limit probe High pressure switch Galvanized steel template Wood return and supply grill Remote mechanical hygrostat Remote mechanical hygrostat + thermostat TFH GRFH HYGR HYGR Standard, Optional, Not available. GH - GHWZ 25 25WZ 50 50WZ 100 100WZ 200 200WZ Limit probe High pressure switch Defrost thermostat Remote mechanical hygrostat Remote mechanical hygrostat + thermostat Delivery and return plenum 90 HYGR HYGR N Standard, Optional, Not available. FH B B B 1 2 Mod. (mm) B (mm) (mm) Kg 1 681 545 223 38/45 (1) 2 750 660 20 -- 3 717,6 632 226,6 -- 3 (1) WZ Version www.hidros.eu 141

B Mod. (mm) B (mm) (mm) Kg 25 257 582 582 35 50 352 582 582 52 100 392 800 730 87 200 464 888 930 115 25WZ 257 582 582 37 50WZ 352 582 582 55 100WZ 392 800 730 90 200WZ 464 888 930 120 Refrigerant circuit standard version The functioning of the dehumidifier model FH-GH is as follows: the fan takes the air from the ambient (7) and it s made go through the filter (1) and the pre-cooling water coil (2) where it s cooled and brought to a condition closed to saturation. Now it passes through the evaporating coil (3) where it s fatherly cooled and dehumidified. The air passes now through the condensing coil (5) where it s post heated (with a constant humidity) and in the post-cooling coil (6) where it s reported to the required conditions. ll the dehumidifiers model FH-GH can work without the help of the pre and post cooling coils. This function is very useful in case there is the request of dehumidification in middle-season or when the chiller is off. Obviously, if the unit works without the help of the cold water, the air in outlet will be hotter than the air in inlet. Refrigerant circuit WZ version The operation of the dehumidifier model GH is as follows: the fan takes the air from the ambient (7) and it s made go through the filter (1) and the pre-cooling water coil (2) where it s cooled and brought to a condition closed to saturation. Now it passes through the evaporating coil (3) where it s fatherly cooled and dehumidified. t this point there are two possible modalities: Modality with neutrum air. The air passes now through the condensing coil (5) which allows to condensate the 50% of the total gas, (the unit condensate the 50% on air with the heat exchanger (5) and the 50% in water with the heat exchanger (10)) then there is the post-heating so that to avoid to send air in the ambient in neutrum thermic conditions. 142 Modality with cooled air. The unit condensates the 100% in water through the heat exchanger (10). The air, then, go through the condenser (5) (disabled) where does not change its characteristics (temperature and humidity).

Standard version WZ version 3 5 3 5 7 7 1 2 6 1 2 10 9 8 9 8 4 4 1 2 3 4 5 ir filter Pre-cooling coil Evaporator ompressor ondenser 6 7 8 9 10 Post-cooling coil Fan Dry filter Expansion device ondenser water Discharge plenum mod. GH 25 50 GH 25 GH 50 160 mm 505 mm 300 mm 160 mm 200 mm 615 mm www.hidros.eu 143