THERMOSTATIC MIXING VALVES FOR CONDENSATION PREVENTION

Similar documents
Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

DEVIATING VALVES ART K063

anti-condensation valve

CALEFFI. Solar storage-to-boiler thermostatic connection kit series 01164/09 GB. Function

Systems for central heating

RA 2000 Series RA 15/6T & TB Conversion Valve

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

STRAIGHT AND ANGLED THERMOSTATIC VALVES

RA15/6T & TB Conversion Valve

CALEFFI. Anti-condensation recirculation and distribution unit. 281 series 01224/14 GB. Replaces dp 01224/12 GB. Function

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

Thermostatic valves with radiator connection systems

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Mercury Mixing Kit (Code: ME1053)

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

caleffi hydronic valves page 1 of 12

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

R146C. Adjustable magnetic dirt separator. Versions and product codes. Datasheet 0840EN 10/2018

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Standard. thermostatic valve body without presetting

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

VST Series. INAIL approved and calibrated safety valves. Technical Data Sheet. WattsIndustries.com

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Thermostatic valve bodies

PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

Section - A. Radiator Valves

Multilux 4-Eclipse-Set

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

product overview ProControl

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Thermostatic mixing valves with replaceable cartridge for centralized systems

Control valves for floor heating systems. Floor Heating Manifolds

Convertible radiator valve for one-pipe systems, centre distance 35 mm

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

Mikrotherm. Manual Radiator Valves With presetting

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

281 Series. ThermoBloc boiler protection recirculation and distribution unit. Installation, commissioning and servicing instructions

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

DIRTMAG dirt separator with magnet, adjustable for vertical or horizontal pipe

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

Installation, commissioning and servicing instructions

Adjustable three-way thermostatic mixing valve... connections ½", ¾", 1" NPT male union and sweat union and ¾" press

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Thermostatic shower valve with 2 way diverter, brass faceplate and handles - V51

TS RD 7761 RD, 7761 RD

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Thermostatic valve bodies

CALEFFI. water heater tank mixing valve. TankMixer. 520 series 01267/17 NA

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

Installation and Servicing Instructions. Alpha FlowSmart

INSTALLATION & COMMISSIONING INSTRUCTIONS Model: 990 CH

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104

WAL-RICH CORPORATION SINCE 1950

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Data sheet Thermostatic sensors type RA 2000

Eliminator TotalGuard Installation Manual

Flush individual room control for floor heating systems

manifold, for radiators

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

Forced draught gas burner

LYRA 1000 VVS Installation and Operation Manual LYRA 1000 VVS THERMAL STORE LYRA 1000 VVS

BOILER FOR HOT WATER AND STEAM

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

thermostatic valve body with stepless precision presetting

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

Three-way reversing valve

Thermostatic shower valve with 3 way control, brass faceplate and handles - V52

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

Dovre 250 Cast Iron Gas Stove

SERVICE MANUAL. WS-55 Hobart Compact Water Softeners Installation Instructions - NOTICE - WS-55

ACCREDITED. Product range Code A2L Modulating temperature regulating unit for heating and cooling, with ALPHA2 L pump.

Trade Product List 2013 BIOMASS ACCESSORIES

function Adjustable thee-way thermostatic mixing valve... connections 1/2", 3/4", 1" NPT male union and sweat union

Automatic balancing valves ASV-PV (new generation) DN 32-50

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

Checklists LAUNDRY GREENKEYGLOBAL.COM

GENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Light oil burners. One stage operation

Radiator Valve Program

Instruction Sheet LTR - Low Water Cutoff for Hot Water Boilers

RA2000 Commercial TRVs

Transcription:

DT SHEET THERMOSTTIC MIXING VLVES FOR CONDENSTION PREVENTION woody art.v13 woody art.v14 Description Barberi thermostatic mixing valves woody are devices with side mixed water and are used to set the fluid s temperature. Their standard application is in heating systems for solid fuel installations, powerhouse, heat generators (wood boilers, pellet boilers, wood chips boilers). Their function is to maintain the fluid s temperature from boiler over a fixed value. This function allows to reduce condensation from steam deriving from fumes which causes dirty on thermal exchange surfaces and chimney. Thanks to this function the valve allows boiler s high efficiency and reduces encrustations and dust from un-burnt material which damages draught and can be subject to fire. Valves of this range can be supplied with fittings and nuts and if need to be connected directly to a pump the same valves but with running nuts can be more suitable. Product range art. ref. V13 art. ref. V14 Thermostatic mixing valve for solid fuel heating systems - KV3,2 Thermostatic mixing valve for solid fuel heating systems - KV9 Features Max. and minimum working temperature: 5 C 100 C Max working pressure: 10 bar Setting range: 45 C 55 C 60 C 70 C ccuracy: ±2 C Flow coefficient: = Kv 3,2 = Kv 9 Suitable fluids : water for heating plants, glycole water(max 50%), sanitary water Connections to circuits: threaded male connections ISO 228/1 threaded female connections UNI EN 10226-1 Materials 1 - Valve s body: Brass UNI EN 12165 CW617N(V13) Brass UNI EN 1982 CB753S(V14) 2 - Obturator: Brass UNI EN 12164 CW614N 3 - Washers: EPDM 4 - Spring: Stainless steel ISI 302 Barberi Rubinetterie Industriali s.r.l. 13018 VLDUGGI (VC) ITLY Via Monte Fenera, 7 Tel. 0039 0163 48.284 r.a. Fax 0039 0163 48.287 e-mail: barberi@barberi.it website: http://www.barberi.it 1

DT SHEET THERMOSTTIC MIXING VLVES FOR CONDENSTION PREVENTION Working way Thermostatic mixing valves from V13 and V14 range are normally used to maintain at a high level the inlet boiler s temperature where risk of condensation needs to be avoided. Temperature setting is done through a built-in thermostatic element which extends or shortens according to fluid temperature thus regulating the opening of both inlets. These valves have a fixed pre-set temperature which cannot be modified. The same valve can be used as mixing valve or as diverting valve simply replacing the supplied labels. If the valve is correctly chosen and used as mixing valve it guarantees the condensation s prevention. (fig.1) Fig. 1 Working way as mixing valve -B B Used as diverting valve or zone valve (fig.2) the valve connects or disconnects the consumption according to the inlet temperature (high or low). This function does not guarantee to prevent condensation into the boiler but guarantees a supply temperature higher than the valve setting value. Fig. 2 Working way as diverting -B B Barberi Rubinetterie Industriali s.r.l. 13018 VLDUGGI (VC) ITLY Via Monte Fenera, 7 Tel. 0039 0163 48.284 r.a. Fax 0039 0163 48.287 e-mail: barberi@barberi.it website: http://www.barberi.it 2

DT SHEET THERMOSTTIC MIXING VLVES FOR CONDENSTION PREVENTION Working way to prevent condensation T < Tset Phase 1 When the system is started fluid coming from boiler is cold and has a temperature Ta lower than the valve setting Tset. In this situation the by-pass circuit is totally open and fluid coming from boiler will go completely back to it allowing to temperature to rapidly increase. By this way the initial gap of condensation risk is reduced. Tset<T < Tset + 10 C Phase 2 Whilst the temperature Ta increases and once the set temperature Tset is exceeded, the valve begins to reduce the by-pass and opens the way back from cylinder. The inlet temperature from boiler is the same of the pre-set temperature of the valve. By this way condensation is avoided. Tset<T < Tset + 10 C Phase 3 Whilst boiler s temperature Ta and fluid s temperature coming from cylinder increases, the valve mixes the water and closes the by-pass, allowing more flow towards the cylinder. T > TSET + 10 C Phase 4 When the boiler s temperature Ta is higher of about 10 C the pre-set Tset temperature of the valve, the valve totally diverts the flow, completely closes the by-pass allowing to consumption to use the whole flow coming from boiler. Barberi Rubinetterie Industriali s.r.l. 13018 VLDUGGI (VC) ITLY Via Monte Fenera, 7 Tel. 0039 0163 48.284 r.a. Fax 0039 0163 48.287 e-mail: barberi@barberi.it website: http://www.barberi.it 3

DT SHEET THERMOSTTIC MIXING VLVES FOR CONDENSTION PREVENTION Dimensions G1 G G1 G G G1 H H1 L L1 D Code P [bar] G G1 L L1 H H1 D Side valves Temperature Weight N. P/B N. P/C V13 M25 00 L1 10 1 M 3/4 M 70 130 81 111 39 adapters 45 C 765 1 20 V13 M25 00 10 1 M - 70-81 - 39-45 C 465 1 20 V13 M25 00 L2 10 1 M 1 M 70 138 81 115 39 adapters 45 C 867 1 20 V13 M25 00B L1 10 1 M 3/4 M 70 130 81 111 39 adapters 55 C 765 1 20 V13 M25 00B 10 1 M - 70-81 - 39-55 C 465 1 20 V13 M25 00B L2 10 1 M 1 M 70 138 81 115 39 adapters 55 C 867 1 20 V13 M25 00C L1 10 1 M 3/4 M 70 130 81 111 39 adapters 60 C 765 1 20 V13 M25 00C 10 1 M - 70-81 - 39-60 C 465 1 20 V13 M25 00C L2 10 1 M 1 M 70 138 81 115 39 adapters 60 C 867 1 20 V13 M25 00D L1 10 1 M 3/4 M 70 130 81 111 39 adapters 70 C 765 1 20 V13 M25 00D 10 1 M - 70-81 - 39-70 C 465 1 20 V13 M25 00D L2 10 1 M 1 M 70 138 81 115 39 adapters 70 C 867 1 20 Code P [bar] Weight (grams) - N. P/B: number of pieces in box, plastic bag - N. P/C: number of pieces in carton G G1 L L1 H H1 D Side valves Temperature Weight N. P/B N. P/C V14 025 00 10 Rp1 F - 93-103 - 55-45 C 908 1 12 V14 M32 00 L1 10 G1 1/4M G1 M 93 163 103 138 55 adapters 45 C 1409 1 12 V14 M32 00 10 G1 1/4M - 93-103 - 55-45 C 905 1 12 V14 025 00B 10 Rp1 F - 93-103 - 55-55 C 908 1 12 V14 M32 00B L1 10 G1 1/4M G1 M 93 163 103 138 55 adapters 55 C 1409 1 12 V14 M32 00B 10 G1 1/4M - 93-103 - 55-55 C 905 1 12 V14 025 00C 10 Rp1 F - 93-103 - 55-60 C 908 1 12 V14 M32 00C L1 10 G1 1/4M G1 M 93 163 103 138 55 adapters 60 C 1409 1 12 V14 M32 00C 10 G1 1/4M - 93-103 - 55-60 C 905 1 12 V14 025 00D 10 Rp1 F - 93-103 - 55-70 C 908 1 12 V14 M32 00D L1 10 G1 1/4M G1 M 93 163 103 138 55 adapters 70 C 1409 1 12 V14 M32 00D 10 G1 1/4M - 93-103 - 55-70 C 905 1 12 Weight (grams) - N. P/B: number of pieces in box, plastic bag - N. P/C: number of pieces in carton Barberi Rubinetterie Industriali s.r.l. 13018 VLDUGGI (VC) ITLY Via Monte Fenera, 7 Tel. 0039 0163 48.284 r.a. Fax 0039 0163 48.287 e-mail: barberi@barberi.it website: http://www.barberi.it 4

DT SHEET THERMOSTTIC MIXING VLVES FOR CONDENSTION PREVENTION Installation Before installing a woody thermostatic mixing valve please verify system s working conditions, such as pressure and temperature, to be sure that they are within the working conditions of the valve. The system, where Woody will be installed, shall be cleaned and flushed before installing the valve. We suggest also to install suitable filters at the system. Without a suitable cleaning of the system the correct working of the valve can be damaged and the manufacturer guarantee upon the product could fail. If the valve will be used with hard water, we suggest to install devices to soften water before the valve s inlet. It is important that the valve is free from obstacles for its duly maintenance. Positioning Woody thermostatic mixing valve can be installed in any position (fig.3) Fig. 3 Configuration The valve is supplied with labels indicating its application as mixing valve to prevent condensation (fig.4). For different necessities, the valve can be used as diverting valve (fig.5) replacing the labels of the valve with the ones contained in the box (see labels replacement operations). Fig. 4: Working way as mixing valve(using for condensation prevention) Fig. 5: Working way as diverting Barberi Rubinetterie Industriali s.r.l. 13018 VLDUGGI (VC) ITLY Via Monte Fenera, 7 Tel. 0039 0163 48.284 r.a. Fax 0039 0163 48.287 e-mail: barberi@barberi.it website: http://www.barberi.it 5

DT SHEET THERMOSTTIC MIXING VLVES FOR CONDENSTION PREVENTION Labels replacement Fig. 6 The valve is supplied as per fig.6 under standard conditions. To move from mixing valve configuration (fig.7) to the diverting one(fig.8), follow these steps: Fig.7 Fig.8 1. 1)Observe the nick on the valve s body; the nick indicates the mixing port whilst in configuration to prevent condensation (standard) or the inlet way whilst in diverting configuration 3. Position the valve as in figure observing the nick on the valve s body 4. Place the labels supplied in the box on the valve s body and push with fingers to make them adhere completely to the surface. Check the positioning of the front and of the rear label as in figure 2. Take off the labels from valve s body Barberi Rubinetterie Industriali s.r.l. 13018 VLDUGGI (VC) ITLY Via Monte Fenera, 7 Tel. 0039 0163 48.284 r.a. Fax 0039 0163 48.287 e-mail: barberi@barberi.it website: http://www.barberi.it 6

DT SHEET THERMOSTTIC MIXING VLVES FOR CONDENSTION PREVENTION Diagrams Q[l/h] 0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 21,0 210,0 V13 V14 20,0 200,0 KV3,2 KV9 19,0 190,0 DP[m] 18,0 17,0 16,0 15,0 14,0 13,0 12,0 11,0 10,0 9,0 8,0 7,0 6,0 5,0 4,0 3,0 2,0 1,0 180,0 170,0 160,0 150,0 140,0 130,0 120,0 110,0 100,0 90,0 80,0 70,0 60,0 50,0 40,0 30,0 20,0 10,0 DP[kPa] 0,0 0,0 0,0 1,0 2,0 3,0 4,0 5,0 6,0 7,0 8,0 9,0 10,0 11,0 12,0 13,0 Q[m3/h] Specifications The specification s text refers to a specific article reference. Each version of the product obliges the engineer to modify the specification s text rt.ref. V13 M25 00 L1 Thermostatic mixing valve with pre-set fixed temperature to prevent condensation s usage. Connections through ¾ nut and fitting. Materials: brass body, brass plug, brass obturator, stainless steel spring, EPDM washers. Max. working pressure 10bar, working temperature range 5-100 C. Setting temperature 45 C±2 C. Flow value Kv3,2 rt.ref. V13 M25 00B Thermostatic mixing valve with pre-set fixed temperature to prevent condensation s usage. 1 M threaded connections. Materials: brass body, brass plug, brass obturator, stainless steel spring, EPDM washers. Max. working pressure 10bar, working temperature range 5-100 C. Setting temperature 55 C+/-2 C. Flow value Kv3,2 rt.ref. V14 M32 00C L1 Thermostatic mixing valve with pre-set fixed temperature to prevent condensation s usage. 1 fitting and nut connections. Materials: brass body, brass plug, brass obturator, stainless steel spring, EPDM washers. Max.working pressure 10bar, working temperature range 5-100 C. Setting temperature 60 C+/-2 C. Flow value Kv9 rt.ref. V14 025 00D Thermostatic mixing valve with pre-set fixed temperature to avoid condensation s usage. Rp1 F threaded connections. Materials: brass body, brass plug, brass obturator, stainless steel spring, EPDM washers. Max. working pressure 10bar, working temperature range 5-100 C. Setting temperature 70 C+/-2 C. Flow value Kv9 Barberi Rubinetterie Industriali s.r.l. 13018 VLDUGGI (VC) ITLY Via Monte Fenera, 7 Tel. 0039 0163 48.284 r.a. Fax 0039 0163 48.287 e-mail: barberi@barberi.it website: http://www.barberi.it 7

DT SHEET THERMOSTTIC MIXING VLVES FOR CONDENSTION PREVENTION ccessories rt.ref. P93 Running nut fitting with flat washer rt.ref. Y77-2 Running nut fitting with flat washer Max. working temperature: 100 C Max. working temperature: 100 C code P93 020 000 P93 025 000 size G 3/4 M - G 1 F G 1 M - G 1 1/4 F code size Y77 25 000 2 1 M x 1 Related articles rt.ref. 14G Distribution group for solid fuel boiler. Ensures a high return temperature which prevents condensation. woody rt.ref. V13/R Thermostatic mixing valve for solid fuel boilers - pump connection rt.ref. 450 4-way mixing valve - F. rt.ref. P27T Mixing valve actuator, running angle 90, with built-in probe and temperature control. Comes complete with blocking screw, mixing valve adaptor, anti-rotation pin, NTC (1m wire) probe, probe housing, European plug electrical wire (2m wire) Barberi Rubinetterie Industriali s.r.l. 13018 VLDUGGI (VC) ITLY Via Monte Fenera, 7 Tel. 0039 0163 48.284 r.a. Fax 0039 0163 48.287 e-mail: barberi@barberi.it website: http://www.barberi.it 8 10102013