HRX Technical Manual. Version 1.2

Similar documents
HRX3000. Technical Manual

UNC100 Integra Manual

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

USER MANUAL FOR OPERATING SYSTEM

P2267 NETWORK INTERFACE

Networked Access Control Panel. Installation Guide

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

Ethernet General Purpose

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

ARCHITECTURAL DOOR HARDWARE KEY PADS & CARD READERS CATALOG

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

SC-F3G User Manual 1.0

T4000 Security Communicator

21-light Remote Annunciator. Owner s Manual

HARDwired Installation/ Owner s Manual

Model A1700 Series Annunciator

General Purpose IO Technical Manual

CARD ACCESS CONTROL SYSTEM

InBio X60 Series Access Control Panel User Manual

Pipo Communications. Model ST-888. DTMF ANI/ENI Display Decoder

SCR100 User Manual. Version:1.1 Date:Dec 2009

Model A2100 Series Annunciator

KT-100 Door Controller

Installation Guide for inbiox60 Series Access Control Panel

Fratech Multipath-IP

Eclipse Nursecall Systems Ltd. Clipper Plus & Clipper ID. Document V.2.1b (Basic) ENS. Freedom Through Technology

600 Range Dialer Installation Manual. Version 1.0

PAC Portico 2200/1200 Series Door Controllers

Carbon Monoxide Transmitter

TX3 Series TX3-CX-1. Installation Manual

Integrated Security Solutions

GLOBAL. InstallatIon & operation manual

CV-350 TCP/IP Access Control System. System Overview

G SERIES: Security INTEGRATION as you want it. Greater expansion, communication, video integration, system resilience, and automation.

PTE0705 Electric Fence Monitor

NU2 Smart Power Supply (SPS) Manual

EverAccess. User Manual. Volume

IRIS Touch Firmware Enhancements and Additions from Version to Version

EC-P Zone Intruder Alarm System

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

Application Version: 2.0 and above Date Written: 03/09/2010. Copyrights , Global Security Devices, All Rights Reserved

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

OPERATION & INSTALLATION MANUAL FOR ALARM PANEL M2AP01

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Installation Manual GalaXy G2 / G3 / GD. o Settings GalaXy o Linking with iprotect o Keymap

Sentient. Downloader Manual D4854

TruPortal Wireless Locks Quick Reference

Product Data Sheet. Remote Terminals. Features:

ACCURATE ELECTRONICS INC

User manual. KNXgal. version

Roo232 User Guide. Revision 1.0. Copyright 2006 RoboDynamics Corp

A36D/TPSD Modbus TCP SCADA INTERFACE INSTRUCTIONS

REPEATER FS5200R INSTRUCTION MANUAL

Added password for IP setup page : Password must be in IP format!

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

Integrated Security Solutions

C-Bus Pascal Automation Controller 5500PACA. Installation Instructions

System Manual W A R N I N G. PC6O1O Software Version 2.1

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Grandstream Networks, Inc. GDS3710 Input/output Alarms Configuration Guide

Dry Contact Probe DCP (#30008)

All- IN- ONE PROXIMTY STAND ALONE CONTROLLER OPERATION MANUAL MODEL: HA3021 VERSION: 3.60

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

SMARTWIRE MKII INSTALLATION MANUAL HARD-WIRED NURSE CALL SYSTEM. SmartWire MK2 Nurse Call Installation Manual v1.8.doc

Products no longer available

AKSolutions Data Sheet April 2007 AK882X RF POWER MONITOR. Description: Features:

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

DS7400Xi Addressable Control/ Communicator

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

General Routing Interface

In installation with more doors, up to 64 central units can be used together, allowing installations of up to 2,048 doors. RECEPTION CAR PARK

Remote alarm indicator and test combination MK2430

Access CONTROL. MANAGEMENT Software

RS485 MODBUS Module 8AI

D3 Wireless temperature alarm & monitoring system family. tek-troniks

CASS9000 Standalone FingerPrint Door Access System. User Manual

System 57. An advanced World of intelligent gas detection system management

20 Light Remote Annunciator

Analog Room Pressure Monitor RPC Series

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

System 57. An advanced world of intelligent gas detection system management

Installation & User Manual V1.1

Metasys Integrator Vilter Application

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

PowerLogic ION Setup Meter Configuration Software Configuration Guide

Intelligent Security & Fire Ltd

Inner Range FE3000S. Serial GSM Modem. P/No: INSTALLATION MANUAL

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

Installation and Technical Documentation

Instruction Manual Model Backup Switch, 1 for 8

Installation, Operating and Maintenance Manual

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

DYGIZONE GJD910 Lighting Controller & Enunciator

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

RMS/RPX Reader. User Manual

725B Configuration Software Manual

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Synergis Master Controller 2.2 Integration Guide for Assa Abloy Aperio- Enabled Locks

ZLM4 OEM Technical Manual

Transcription:

HRX 5000 Technical Manual Version 1.2

Contents: Specification...2 Connectors...5 RS-485 Network Connectors (J6 and J7)...5 RS-232 to Printer (J19)...6 RS-232 to PC (J8)...7 TCP/IP...8 Power (J21)...9 Fire Alarm Input (J20)...10 Relays (J12, J15)...11 Remote Readers (J13, J16)...12 Remote Door Inputs (J14, J17)...13 Modem (J3)...14 Access Control...15 Fire Alarm Interaction...16 Bells...16 Fire Alarm Printer...16 Issue History...18 HRX5000 Technical Manual V1.2 Page 1 of 18

Specification The HRX 5000 is a Proximity card reading terminal with TCP/IP connection, Fire Alarm printout, Access Control for 2 doors and optional internal Modem. HRX5000 Technical Manual V1.2 Page 2 of 18

Dimensions: Display: Clockings: Employees: Firmware: Configuration: 280mm (W) X 170mm (H) X 60mm (D) 16 X 2 Large character LCD with LED Backlight Display area: 100mm X 25mm 15,000 in circular buffer 25 to 1,000, remotely upgradeable Flash memory upgradeable over TCP/IP 1 Master, up to 15 Slaves Reader: Type: 125KHz HID type Range: 80mm (ISO & Clamshell badges) 30mm (Keyfobs) Battery Backup: Enclosure: Weight: UPS: Lithium battery for data and clock for 3 years Material Flame retardant ABS IP rating standard purchase is unsealed Optionally sealed to IP66 (hosedown) 1 KG. Optional external HRX5000 Technical Manual V1.2 Page 3 of 18

Connections: Power 9-12v DC 350mA to 500mA TCP/IP 10/100 Base-T RS/232 Second, alternative, PC connection RS485 Slave clocks. 2 connectors for buss RS232 Fire Alarm printer Digital IN Fire Alarm Panel Remote Reader A 8 core up to 50 metres Relay A SPCO up to 250V 0.5A Door Ajar A From magnetic contact Egress A From egress button Remote Reader B 8 core up to 50 metres Relay B SPCO up to 250V 0.5A Door Ajar B From magnetic contact Egress B From egress button Modem Line connector Modem Options: Power Supply: Internal PSTN type Internal GSM type (data SIMM contract required) Wall Mount IN: 240V AC OUT: 9V DC 95mm X 45mm X 25mm HRX5000 Technical Manual V1.2 Page 4 of 18

Connectors RS-485 Network Connectors (J6 and J7) J6, J7 Pin Signal Direction 1 -ve In/Out 2 +ve In/Out 3 4 Screen J6 J7 A Master HRX5000 is able to communicate with up to 15 Slave HRX5000s (or HRX3000s) over a twisted pair RS-485 bus. 2 connectors are fitted in each clock to make wiring easier in the field. End to end cable length can be up to 1Km. The cable required is single twisted pair with shield. A suitable cable is Belden 9501 which is 24 awg (7X32) stranded, single twisted pair with shield, PVC insulation. The RS Part Number 382-576 is for 1 box of 304 metres at 75. J6 and J7 are connected pin to pin on the PCB. I.e. J6 pin 1 connects to J7 pin 1 etc. To connect 2 units together, wire pin 1 to pin 1 and pin 2 to pin 2. Keep the screen pigtail as short as possible. HRX5000 Technical Manual V1.2 Page 5 of 18

RS-232 to Printer (J19) J19 Pin Signal Direction Printer DB-25 Notes 1 Power Out 5-9 volts available to power an external line driver. Current limited to approx 50mA 2 TXD Out RXD pin 3 Transmit data. 9600 baud, 8 data, 1 stop, no parity 3 RXD In RTS pin 20 Hardware handshake from printer. Connect to Printer RTS (Output) signal 4 0V 0V pin 7 Signal Ground J19 The terminal uses an RS-232 output to a printer for the Fire Alarm evacuation reports. The report is triggered by a contact closure on the Fire Alarm Input. It can also be initiated from the PC. The data format of the transmitted data to the printer is: 9600 baud, 8 Data bits, 1 Stop Bit, No Parity. Using the Focus Software it is possible to command test printouts to be sent from the Terminal to the printer. It is also possible to inspect the state of the Printer's hardware handshake line. See menu option System Fire Alarm. HRX5000 Technical Manual V1.2 Page 6 of 18

RS-232 to PC (J8) J8 Pin Signal Direction Notes 1 Power Out 5-9 volts available to power an external line driver. Current limited to approx 50mA 2 TXD Out Transmit data. 19,200 baud, 8 data, 1 stop, no parity 3 RXD In Receive data. 19,200 baud, 8 data, 1 stop, no parity 4 0V Signal Ground J8 The terminal can communicate with the PC either by TCP/IP, RS-232 or Modem. The connection method is set up in the Focus System Clock Utilities Connection Setup screen. Here you specify a terminal name and a connection method. Connections: Pin Signal Direction PC 9 Way PC 25 Way 1 Power Out 2 TXD Out RXD (pin 2) RXD (pin 3) 3 RXD In TXD (pin 3) TXD (pin 2) 4 0V 0V (pin 5) 0V (pin 7) HRX5000 Technical Manual V1.2 Page 7 of 18

TCP/IP TCP/IP The TCP/IP connection supports Ethernet 10/100 Base-T. The IP address of the unit is set up via the Focus software using the System Clock Utilities TCP/IP Tab. A password is required to modify the TCP/IP address of the unit as inadvertent changes will cause loss of communication. You would normally modify the IP Address by communicating over the RS232 cable from the PC. HRX5000 Technical Manual V1.2 Page 8 of 18

Power (J21) J21 Pin Signal Direction Notes 1 0V Signal Ground connected to pin 2 2 0V 3 +ve In 9-12 volts DC at up to 500mA 4 +ve In Connected to Pin 3 J21 The unit requires 9 to 12 volts DC at up to 500mA depending on configuration. The unit is protected internally against reverse polarity connection. HRX5000 Technical Manual V1.2 Page 9 of 18

Fire Alarm Input (J20) J20 Pin Signal Direction Notes 1 FA In Fire Alarm Input 2 0V Signal Ground 3 FA In Connected internally to Pin 1 4 0V Connected internally to Pin 2 J20 The Fire Alarm Input triggers the Fire Evacuation Report to be printed via the RS-232 printer port. A voltage free pair of contacts triggers the report on contact closure. The connections are doubled up on the connector with Pins 1 and 3 connected and Pins 2 and 4 connected. If desired, a push button switch can be connected to one pair and the Fire Alarm panel connected to the other pair. This will give a manual test or trigger input. Pins 1 and 3 will normally show +5 volts with both inputs open circuit. HRX5000 Technical Manual V1.2 Page 10 of 18

Relays (J12, J15) J12, J15 Pin Signal Direction Notes 1 NC In/Out Normally Closed Contact 2 C In/Out Common Contact 3 NO In/Out Normally Open Contact J12 J15 The two relays each provide one set of changeover contacts for operating a door release mechanism or a sounder. The contacts are rated at up to 240 volts AC 100mA, or 12V DC 2 Amps. The contacts are protected internally by transient suppressing Varistors. HRX5000 Technical Manual V1.2 Page 11 of 18

Remote Readers (J13, J16) J13, J16 Pin Signal Colour Direction Required 1 9 Volts Red In Yes 2 Card Load Signal Violet In 3 Signal Ground Black Yes 4 Data Green In Yes 5 Clock White In Yes 6 Green LED Orange Out Yes 7 Red LED Brown Out 8 Sounder Yellow Out NB: Pin 1 located at the TOP of the connector J13 J16 Recommended cable for extending the reader distance: Belden 9538 which is 8 core 24 awg (7X32) with overall screen. RS Part number 382-475 is for 304 metres at 175. HRX5000 Technical Manual V1.2 Page 12 of 18

Remote Door Inputs (J14, J17) J14, J17 Pin Signal Direction Notes 1 AJAR In Door Ajar 2 0V 3 EXIT In Exit Pushbutton 4 0V J14 J17 Pin 1 and 2 connect to a normally closed door sensor such as a magnetic reed contact. The contacts open when the door opens. With the contacts open there is a 5 volt signal present on Pin 1. Pin 3 and 4 connect to a Door Exit pushbutton. These contacts are normally open when there will be a 5 volt signal on Pin 3. Egress timing is carried out by the software in the terminal. HRX5000 Technical Manual V1.2 Page 13 of 18

Modem (J3) Modem J3 The unit can accept a plug in Modem which sits underneath the LCD. The footprint is compatible with a PSTN landline modem or a GSM radio modem. The PSTN Modem connects to the phone line via J3 which is a standard modem line socket. The GSM modem has a flying lead connecting to an aerial which, for best results, should be mounted remotely from the clocking terminal itself. HRX5000 Technical Manual V1.2 Page 14 of 18

Access Control The HRX5000 supports Access Control for 2 Doors. Two independent groups of connectors allow for connection to: 1. Proximity reader; 2. Door release device (latch or magnet) driven by a built in changeover relay; 3. Door open sensor; 4. Door Exit button. Each relay has an alternative use as a bell actuator. 1. Proximity Reader. With the recommended minimum 5 wire connection the LED/Sounder sequence is as follows: LED Sounder Indicating Idle Red Power ON Card Presented Flashes GREEN Beeps Card read If Access Granted Relights GREEN Access Grant for the duration the Door is released If Access Denied Remains RED Access Deny 2. Door Release. The contacts are rated at up to 240 volts AC 100mA, or 12V DC 2 Amps. The contacts are protected internally by transient suppressing Varistors. 3. Door Open sensor. Connects to a set of contacts that are closed when the door is closed (such as a magnetic reed switch). These contacts are monitored and can initiate a Door Forced Alarm and a Door Ajar Alarm. 4. Door Exit switch. Connect a Normally Open push button to this input to release the door for a predetermined interval. When the contacts close (button pressed) the door relay will operate (door released). When the contacts open (button released) the Door Release timer starts. This can be set from the Focus software Access Control Doors screen. At the end of the timeout period the relay will de-energise, locking the door. HRX5000 Technical Manual V1.2 Page 15 of 18

Master/Slave systems In a Master/Slave configuration, the master holds all the Door Rules and the Access Rules as well as the Access Clocking Records. The Access Clocking records are downloaded at the same time as the Time and Attendance Records. The Master holds: 20 Door Rules 100 Access Rules 100 Access Groups 10,000 Time & Attendance and Access clockings Fire Alarm Interaction Each door can be individually programmed to unlock on Fire Alarm activation. This is carried out by setting the Fire Alarm Release timer in the Door Definition within Focus Clock Utilities. Bells The HRX5000 holds up to 20 Bell time records that can be shared between the 2 relays. Each record specifies: The relay 1 or 2 The activation time in hours and minutes (no seconds) The duration in seconds (up to 60 seconds) The days of the week on which the rule applies. Fire Alarm Printer The terminal uses RS-232 to send data to the fire alarm printer. This enables a dedicated cable to be used (rather than using the network infrastructure) and distances of around 50 metres can be achieved. The printer must be capable of printing 'Raw Text'. Many printers only work when driven by an application using Windows or similar printer drivers. Before sourcing a printer ensure it can print raw text and has either an RS-232 interface (preferable) or a 'parallel Centronics' interface (also referred to as IEEE 1284 Bi-directional parallel). HRX5000 Technical Manual V1.2 Page 16 of 18

Recommended Printer: OKI B4250 Mono Laser plus optional serial RS-232 interface. Source www.printerland.co.uk. If the printer does not have a serial interface it is possible, though less convenient, to use an external Serial-to-Parallel converter. This must be capable of converting serial data in the format 9600 Baud, 8 data bits, 1 Stop bit to Parallel data. One such converter is the 'Autostop' or SPC-10 converter. This requires an external power supply delivering 9 to 12 volts AC or DC. If DC is used the polarity on the connector must be observed, which is NEGATIVE TO THE TIP. Wire the 25 way connector in accordance with the table for J19. In normal operation, all the DIP switches on the converter should be OFF, giving the correct baud rate and word format for the terminal. Note that it is not possible to interface to a printer USB port. HRX5000 Technical Manual V1.2 Page 17 of 18

Issue History Issue Date Firmware Focus Changes V1.0 July 2006 Original Issue V1.1 11/9/2006 2.002 2.07 Access Control and Bells Descriptions Added V1.2 29/9/2006 Fire Alarm printer details added. HRX5000 Technical Manual V1.2 Page 18 of 18