Architectural Specification Sheet

Similar documents
DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

ARCHITECTURAL SPECIFICATIONS

Engineering Specifications

5600 series. Low Energy Power Operator

BLG77 Rising Fenced Barrier

SECTION DOOR HARDWARE

5900 Series X-in Low Energy Power Operator

5900 SERIES Low Energy Power Operator

RITTNER FRENCH ASSOCIATES Rittner French Associates / Rittner Products, Inc.

SPECIFICATIONS: FIREGUARD CROSS CORRIDOR CC

BL41 Extra-long Barrier

DIVISION 10 SPECIALTIES

2. Interior doors shall be not less than 18 gauge steel.

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

2409/2900. Fire Guard

SECTION AUTOMATIC TRANSFER SWITCHES

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

PART 1 GENERAL 1.01 SUMMARY

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

2408/2900. Fire Guard

SECTION COMMERCIAL DOOR OPERATORS OVERHEAD RSX FIRE DOOR OPERATOR

BL 53 Security Barrier ENGINEERING SPECIFICATIONS

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors.

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

Carey Automatic Door, LLC 1 - PNEUMATIC OPERATOR FOR SINGLE SWINGING DOOR

Automatic swing door solutions. We make access in life smart and secure.

SECTION INCLINE WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperLite TM I-XL minute SuperLite TM I-XL IGU minute PART 1 GENERAL

SECTION DOOR HARDWARE

A. Section Masonry Assemblies: Anchor placement in masonry.

Linear Heat Detection Engineering Specifications

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

1.3 REFERENCES A. ANSI/NFPA 70 - National Electrical Code. B. ARI Commercial and Industrial Humidifiers.

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

SECTION INTRUSION DETECTION

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

ARBOR SERIES WOOD WALLCOVERINGS

2018 Special-Lite ALUMINUM HARDWARE & LITES

ARBOR SERIES DIVISION FLEXIBLE WOOD VENEER WALLCOVERING

PART 1 GENERAL 1.01 SUMMARY

CARD ACCESS CONTROL SYSTEM

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

PART 1 GENERAL 1.01 SUMMARY

NORMS AND REGULATIONS FOR AUTOMATIC DOORS & ENTRANCE CONTROLS

Design & Construction Standards, Revised January

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

SECTION XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

SECTION GENERATOR PARALLELING CONTROLS

PRODUCT SPECIFICATION FireMaster Plus

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

Project No Belleville Fire Hall/Headquarters and Emergency Operations Centre Section Belleville, Ontario Page 1 of 10

EHT/EHTD. Electromechanical Closer-Holder Release Devices

Gas Station & C Store SECTION CWM Job No

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

SECTION INTEGRATED DOOR ASSEMBLIES

AUTOMATIC SWINGING DOOR

Alarm Lock A Division of the Napco Security Group 333 Bayview Avenue Amityville, New York Phone (631) Fax (631)

SECTION (15767) - UNIT HEATERS

B. Section Identification for Fire Suppression Piping and Equipment.

D. Reference Standards (Utilize latest editions available):

SECTION AUTOMATIC TRANSFER SWITCHES

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperClear 45-HS (patent pending)

SECTION ELECTRICAL SYSTEMS COMMISSIONING

FAQs - Codes and Listings

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

SECTION ROTARY-SCREW WATER CHILLERS

security resources international PART I: GENERAL eguardian Series 1.01 SUMMARY 1.02 REFERENCES 1.03 SUBMITTALS 1.04 QUALITY ASSURANCE

ARCHITECTURAL Product Guide

SECTION GAS-FIRED RADIANT HEATERS

Heating & Holding Cabinets

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

SECTION AIR DUCT ACCESSORIES

Guide Specifications. HyperPod System PART 1 - GENERAL 1.01 SUMMARY

Mighty Venter Power Vent System

SECTION SECURITY TESTING AND COMMISSIONING

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

15900 HVAC INSTRUMENTATION AND CONTROLS

CRESTRON: GREEN LIGHT NETWORK LIGHTING CONTROLS 1

SECTION DOMESTIC WATER PUMPS

Guide Specification Model CTG Automatic Transfer Switch

PART GENERAL 1.01 SECTION INCLUDES

CONTENTS AUTOMATIC TRANSFER SWITCHES

Louvers & Dampers April Product Guide Specification SECTION COMBINATION FIRE SMOKE DAMPERS

SECTION FIRE EXTINGUISHER CABINETS

GT1175 Slide Door OWNER S MANUAL

SECTION SPRINKLER SYSTEMS

WALLCOVERINGS WALLCOVERINGS

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

SECTION AUTOMATIC TRANSFER SWITCHES

CP1-C5 COMPACTOR SPECS 2009

Security Considerations for Secure Workplaces

Across-the-Line SERIES MP300 Combined Manual and Automatic

Owner's Manual. Automatic Sliding Doors. for CONTENTS A U T O M A T I C S. A Member of: Distributed by:

EcoAisle Thermal Containment System

Transcription:

Architectural Specification Sheet 1. General 1.01 Summary A. commercial low energy automatic swing door operator that consists of: -Aluminum housing -Electro-mechanical motor -Operator control assembly -Swing arm B. Controls and safety devices C. Accessories D. Related Work: 1. Section 07900 Caulking 2. Section 08400 Entrances and Storefronts 3. Section 08710 Finished Hardware 4. Section 08800 Glazing 5. Section 12670 Entrance Mats 6. Section 16120 Electrical Supply and Termination 1.02 References A. Unit described complies with current ANSI A156.19 for Power Assist and Low Energy Power Operated Doors. B. Unit meets with CSA C22-2 No. 247 standard for Door, Drapery, Gate, Louver, and Window Operators C. Unit meets UL991 Tests for Safety-Related Controls Employing Solid-State Devices D. Unit exceeds BHMA testing - ANSI BHMA A156.19 Section 5 Cycle Testing. (1,000,000 cycles) 1

1.03 Performance Requirements A. Operator to be rated for use on doors weighing up to 400 pounds per leaf. B. Operator capable of operating within temperature ranges of -40 C and +60 C 1.04 Quality Assurance A. Installation and maintenance shall be performed by a factory trained installer and in strict compliance with the manufacturer s recommendations. B. Conform to UL Std. 325 & ANSI-BHMA Std. A156.19 certified to Can. CSA Std. C22.2#247. 1.05 Product Handling A. All materials shall arrive in the manufacturers original sealed, labelled containers. B. Store materials in a dry, protected, well-vented area. Report damaged material immediately to the delivering carrier and note such damage on the carrier s freight bill of lading. C. Remove and dispose of all protective materials after installation. 1.06 Job Condition A. Verify that other trades are complete before installing the automatic swinging door system. B. Mounting surfaces shall be plumb, straight, and secure; substrates shall be proper dimension and material. C. Refer to the construction documents, shop drawings and manufacturer s installation instructions. D. Coordinate installation with the glass, glazing and electrical work. E. Observe all appropriate OSHA safety guidelines for this work. 1.07 Submittals A. Submit under provisions of relevant Section B. Product Data: Submit manufacturer's product data and standard details for automatic operators. C. Shop Drawings: Submit shop drawings detailing exact dimensions for each door unit including door operator details, activation components, and electric hardware interface, wiring details and electrical requirements. D. Anodized/Finish samples must be submitted 2

1.08 Owner s Manual A. Owner s manual to be supplied at time of commissioning. 1.09 Installer Qualifications A. Equipment may be installed by a AAADM certified technician who must also be a factory trained technician. 2.01 Manufacturer A. Omega Automation and Lighting Inc. 105 Haist Ave Unit 7 & 8, Vaughan, Ontario, L4L 5V6. Phone: 905-670-8008 www.omegautomatics.com 2.02 Equipment A. Swing door operator consists of operator housing, swing power operator, electric control, wire harness and connecting hardware. 2.03 Automatic Swing Door Operator A. Operator: Electro-mechanical operator, powered by 24 volts, 1/3 HP motor. B. Operator is handed. To ensure maximum versatility the operator is field reversible and can adapt to varying field conditions. C. Opening Force shall be adjustable by means of one screw, to compensate for different manual push forces required on varying door widths. D. The operator is completely contained in extruded aluminum housing. All aluminum sections are 6063-T5 Super flow alloy. The operator housing width x height shall not exceed 5 1/8 x 4 3/8. Length of operator housing determined by site conditions and/or specifications herein. Motor/gear box shall be secured to operator housing via tamper proof extruded channel on the back member of operator housing. E. Electronic Controls: Microprocessor controlled unit shall control the operation and switching of the swing power operator. The microprocessor control to provide low voltage power supply for all means of actuation. No external or auxiliary low voltage power source will be necessary. The controls include time delay for normal cycle. 3

F. Connecting Hardware: Surface mounted operator is connected to the door by means of a steel door arm. The door arm is secured to the top rail of the swing door using one piece threaded tubular inserts for aluminum doors, 1/4-20 binding head and post screws for wood and hollow metal doors. The standard power arm and connecting arm shall accommodate up to 12" reveals and opening angles to 180 degrees. The arm will be equipped with a mechanical device which will in the case of extreme force, sheer thus protecting any internal mechanical components from damage, in the case of abuse. G. Manual Use: The operator shall serve as a manual door closer in the direction of swing with or without electrical power. H. External Control: A two position switch will be mounted in the end cover of the housing. The switch will be clearly marked, ON/OFF. I. Power Open: When an opening signal is received by the control unit, the door shall be opened at the operator-adjusted opening speed. Before the door is fully open at back check, it slows automatically to low speed. The motor stops when the selected door opening angle has been reached. The motor holds the open position. If the door is obstructed while opening, it will either stop or reverse (field selectable). J. Field Adjustable Open Stop: The operator shall provide a field adjustable mechanical open stop to accommodate opening angles from 80 to 180 degrees. K. Normal Close: Closing shall be provided by means of spring, adjustable tension will be by means of a single screw. L. Power Close/Motor Reverse: Closing shall be provided by means of a spring and motor and removal of clutch. When the hold open time has elapsed, the operator will close the door automatically, using spring force and motor. The door will slow to low speed at latch check before it reaches the fully closed position. The door is kept closed by spring power or extended closing force by the motor. Safety sensors must be installed in this operation. M. Push and Go: Operator can be adjusted to lower the open forces when used manually. Power Assist will be active only while pushing or pulling the door and will allow the door to close when an opening force is no longer applied to the door. N. Electronic Dampening: Operator to include standard electric dampening system which automatically counteracts additional forces applied to the door during the opening or closing cycle by reducing door speed. O. Latching Speed Feature: The electronic control allows for increases of forces to overcome most stack pressure issues. The control automatically compensates for lower manual push forces when 4

the door is used in manual mode. The door must comply with ANSI A156.19, when using this feature. P. Lock engage circuit: If locking is unsuccessful when the door reaches the closed position, the operator will automatically reverse open 10 degrees and reclose to attempt to lock the door. Q. Test of Safety Sensors: If optional safety sensors are specified, the control will monitor the sensors before opening and closing the door. If sensors are not functioning correctly, automation is de-activated, and the door will function as a manual swing door with a door closer. R. Surface applied operators may connect to the face of an existing fire rated labelled door frame or wall. Connecting hardware and UL approved fire exit hardware is required. See UL materials directory. S. A fire alarm contact will be integrated on the unit s control board, upon receipt of a signal from an external source (fire alarm), the unit will close if in an open condition and not operate as an automatic door, until the signal from the external source has been reset. T. Stairwell Pressurization: A fire alarm contact will be integrated on the unit s control board, upon receipt of a signal from an external source (fire alarm), the unit will open if in a closed condition and not operate as an automatic door, until the signal from the external source has been reset. U. Signage: Provide signage in accordance with ANSI/BHMA A156.19 must be used on all applications. V. Built in stops with Holo Chrome socket head cap screws are used in all models. 2.04 Additional Features A. Digital display: The control panel shall utilize a removable LCD display. Programming of unit will utilize English set up commands, not only numeric. Display will show the status of the operator and display fault conditions when detected. B. Control board has required built in relays for release of electric strike, universal bathroom system, pressurization fan, fire alarm signal and card access integration. 2.05 Push Plate Control Device Actuation device is either: A. Hard wired push plate switches. These will be either surface mounted with an appropriate enclosure or in a concealed single gang electrical box. B. Wireless controlled push plate switches. C. Touch less Activation sensor plates adjustable from 2 to 24 may be used: 5

D Option: Suitable bollard for remotely mounting push plates in areas where no suitable mounting for existing methods of mounting the push plates exist. E Option: Push to Activate - is a programmable feature. Push or pull the door open from any position, and the door will gently power open, time out and slowly close. F In the event of power failure, door can be used as a manual door with no damage to the operator. 3. Execution 3. 01 Examination A. The door installer shall verify that the installation area is dry, clean and free of foreign matter. Check as-built conditions and verify the manufacturer s details for accuracy to fit the wall assembly prior to fabrication. Report in writing to the Contractor any conditions detrimental to the proper functioning of the swinging door operator. Correct prior to any installation in accordance to the manufacturer s recommendations. 3.02 Installation A. Install equipment in accordance with the manufacturers installation instructions. Adjust equipment per instructions and current ANSI/BHMA 156.19 American National Standard for Power assist and low energy power operated doors. B. Door Operators: Connect door operators to electrical power distribution system as specified in Division 26 Sections. C. Controls: terminate wire to: controls, press plates, safety sensors. 4.01 Warranty A. Warranted materials shall be free of defect for the normal use period of two years after date of manufacture. Labor and freight costs are not included in warranty. 5. Country of Origin The operator will be manufactured in Canada. 6