Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018

Similar documents
Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017

McQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

Enfinity Console Water Source Heat Pumps 1/2 to 1½ Ton

McQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008

CCH/CCW, VFC/VFW, MHC/MHW, LVC/LVW

Console Water Source Heat Pumps

Console Water Source Heat Pumps

Daikin McQuay. Applied PTAC Air Conditioner and Heat Pump. PDAA, PDAE, PDAF, PDAN, PDHA, PDHE, PDHF Design 3

Air Cooled Scroll Compressor Condensing Unit

McQuay. Applied PTAC Air Conditioner and Heat Pump PDAC, PDAA, PDAE, PDAN, PDAF PDHP, PDHA, PDHE, PDHF Design 1

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

Daikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017

McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Unit Ventilators Self-Contained UAED, UAEQ, UAER, UARQ, UERQ, UAZQ, UAZR, UAZS, UAZU, UAZV Designs D (4), E (5)

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012

Installation and Maintenance Manual OM

Climate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018

(EE1500, EE2000, EE2500, EE3000)

CU0415, CU0715 and CU0920 Service Parts

Engineered for flexibility and performance

Catalog Enfinity Large Horizontal Water Source Heat Pumps with R-410A Refrigerant

CHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION

Operation and Maintenance Manual OM MicroTech III Unit Controller with I/O Expansion Module for Two Compressor Water Source Heat Pumps

Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB. When requesting service or ordering parts, always provide the following information:

Spare Parts Catalogue MV1006

REPLACEMENT PARTS LIST

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

Catalog SmartSource Two-Stage Horizontal & Vertical Water Source Heat Pumps

CU1526, CU2026, CU3030 Service Parts

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

REPLACEMENT PARTS MANUAL

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

Enfinity Large Vertical Water Source Heat Pumps with R-410A Refrigerant

SCE170 SERVICE PARTS

PARTS LIST GEOTHERMAL HEAT PUMPS HRH/HRV & HOT WATER GENERATOR HWG

SERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305

CMS1402 SERVICE PARTS

Product Data. Single-Package Horizontally Mounted Water Source Heat Pumps with Electronic

Daikin McQuay. Pathfinder Air Cooled Chiller Screw Compressor Two Circuit. AWS Vintage A

General Description. Operation

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

MARVAIR COMPAC AIR CONDITIONERS MODELS AVP72AC AND AVPA72AC EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS)

WHIRLPOOL REFRIGERADOR GS2SHGXLQ01

CABINET PARTS For Models: KSC24C8EYW00, KSC24C8EYB00, KSC24C8EYP00, KSC24C8EYY00 (White) (Black) (Stainless) (Monochromatic Stainless)

REPLACEMENT PARTS MANUAL

SCCG50 & SCCP50 Service Parts

CME1856W Service Parts

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com

REPLACEMENT PARTS MANUAL

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

AFE400 SERVICE PARTS

CM R-410A High Efficiency Water Source Heat Pump

Wiring Diagrams DIAGRAM INDEX

REPAIR PARTS LIST REFRIGERATOR. Model No.(s) (White) (Stainless Steel) (Black)

Parts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

CABINET PARTS REFRIGERATOR

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

AAF Herman Nelson. Classmate Conventional Unit Ventilators. AH AV Vintage C

Enfinity Vertical Water Source Heat Pumps

Catalog SmartSource Compact Vertical Water Source Heat Pumps. Model GCV - Vertical Unit Sizes (1/2 thru 6 tons)

Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL

Daikin McQuay. Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit. AWS Vintage B Unit Revision 0B (Code 62)

Daikin Navigator. Water-Cooled Screw Compressor Chiller. WWV JNNS, MNNS, RNNS Vintage A. Replacement Parts List No Revision A 02/2018

NM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...

UNIT PANELS 6/25/2014 9:02:04 AM Page 2 of 23

INSTALLATION, OPERATION, SERVICE & PARTS SUPPLEMENT for

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

REPLACEMENT PARTS MANUAL

SpaceKeeper Console (SKC)

CME1056 Service Parts. Table of Contents

Transcription:

Replacement Parts List No. 700013100 Revision R 11/2018 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 015, 018 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

Contents Parts List Revision History... 3-4 Nomenclature Serial Number... 5 Model Number... 5-6 Electrical Legend... 7 Blower Fan Assembly Motor, Wheel, Fan Housing... 8 Refrigeration Circuit- Compressor, Condenser, Evaporator, Switch & Valves Diagrams... 9 Components...10-11 Control Box- MicroTech III Controls Diagrams... 12 Components... 13. MTIII Control Board Label Location... 14 Field Installed Accessories... 15-18 Critical Parts List... CPL1 WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 2

Parts List Revision History Rev. Date New 05/09 New A 10/09 Page 22- Add retrofit kit P/n 910104352 and retrofit kit P/n 910104353. B 10/09 Page 8- Change Wall Mtd Prgm 1 Heat/1 Cool, ACO, Hardwired stat p/n 668810301 to 668811301. C 06/10 Page 8- Delete page and add MT3 Sensors- MVHC & WMHC.doc. Pages 11-12 Add footnote (*) for color-specific p/ns. Page 22- Change Bub #750 to Bub #140. Page 25- Add control box and stand off descriptions. Add Connectors H1-9. D 7/10 Page 21- Ref #860 change Valve p/n 107266006 to107266008. Ref #860 Change Valve p/n 107266007 to 107266010. Page 26-27- Change Ref # from531 to 53 & 591 to 59. E 4/13 All Pages updated CS6, dwgs and numerous changes done(sheet metal parts deleted). Pages 4-5 Nomenclature changes- C05= F; C11=Y(1st digit); C23=C24= G-N, Y & 1-4. Page 6- Add page for Electrical Legend. Pages 7-9 Field Installed Accessories- Delete Motorized Valve p/n 060977401. Added numeroius Thermostats, Sensors and Wall Plate (p/ns from IM/OM). Add Consle Damper, Comm. Module Kit and Subbase Kit. Add page & arrange to fit. Pages 11-19 Delete all sheet metal for cabinet and chassis components. Footnote 1 added to Controls (pg18) to contact McQuay Parts for sheet metal p/ns. Ref #205 Change Scroll fan p/n 6687938010 to 668793803. Page 12- Add Digrams for Refrigeration Circuit. Page 13- Change sleeve p/n 668955501 to 669543501. Page CPL1 Add Critical Parts List. F 8/13 Page 24- Change contactor p/n 106500101 to 106500102. G 9/13 Page 8- Add right hand subbase kit p/ns 910111375 & 106796206. H 11/13 Rebrand Daikin. Page 24- Change MTIII I/O Exp p/n 668105701 to 668105702. Change MTIII LonWorks p/n 668105801 to 107293070 and BACnet p/n 668105901 to 107293071. CPL1- Change MTIII I/O Exp, MTIII LonWorks & BACnet. I 7/14 Page 19- Change High Pressure Switch p/n 668803601 to 910117560. Page 24- Change Contactor p/n 106500101 to 073300102 and p/n 106500102 to 910140336. J 3/15 Delete cabinet & chassis sheet metal. Numerous changes. Page 9, 11-15- Delete OA Damper, Basic Unit Layout, sheet metal cabinet/chassis components. Page 10- Add motor capacitor p/n 668003109. Add Cabinet/Chassis Components and footnote 1. Page 11-12 Change compressor mounting detail drawing. Change Ref#s for Line Weight, condenser, compressor, plug assy, pressure valve & line weight. Pages 14-15 Delete & combine controls pages 21-24. Add MTIII diagrams for 208-230V & 265V. Change Capacitor, relay DPST, SLTS & transformer p/ns. Pages 13-15 Field Installed Accessories moved from pages 7-9. CPL1- Delete comm cards & expansion valves. Add SLTS. K 4/15 Page 9- Change compressor nut p/n 668383001 to 802012035. Change drain pan p/n 668802701 to 668802702. Page 11- Add Thermostat, LUI 7-day Program p/n 668811101 & Non-Program p/n 668811001. L 10/15 Update to Daikin Format. Page 11- Add I/O Board until 08/12 p/n 668105701. Add footnote for MTIII label location. Page 12- Add MTIII Controls Label Location table and footnote. CPL1- Update to Daikin Format. M 04/16 Title page- Add Design 2. Numerous changes. Page 7- Change indoor motor 208-230V p/n 667994272 to fan assy, rework p/n 668958654. Change indoor motor 265V p/n 667994273 to fan assy, rework p/n 668958655. Page 11- Add LUI keypad thermostat programmable p/n 668811101 & thermistor p/n 669529401 for TStat Retrofit Kits p/ns 910104353 & 910104352. CPL1- Change Motors to Fan Assy, Rework p/ns 668958654 & 668958655.Include only Design 1. CPL2- Add Design 2 critical parts list. N 02/17 Page 7- Ref# 331 Change 25MFD to 2.5MFD. CPL1-CPL2- Revision update. O 11/17 A new RPL was created for Design 2 components. Page 10- Change High Pressure Switch p/n 91017560 to 910171269. CPL1- Update revision. Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330 WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 3

Parts List Revision History Continued Rev. Date P 06/18 Page 12- Add terminal cover, gasket, washer, and nut for compressor mount. CPL1- Update revision. Q 09/18 Page 4- Add page for Parts List Revision History. Pages 5-6 Delete Code 11 1= Bargrille & 4= Double Deflection Adj Grille. Code 22 Add 50VA Control transformer. Page 8- Change capacitor p/n 668003109 to 910181939. Change fan Assy rework p/n 668958654 to 910242642 Pages 9-11- Add Compressor Mounting details and Bub#s and Ref#s 60-67. Change Reversing Valve p/n 910124938 to 910198409 and 910110418 to 910198406. Change solenoid p/n 106694207 & 910110439 to 910198415. Pages 15-18- Numerous changes. Delte filter kit p/n. CPL1- Update revision. R 11/18 Page 11- Add electric heater p/n 667994908. CPL1- Update revision. WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 4

Nomenclature Plant Identification AUB = Auburn SLP= San Luis Potosi Serial Number AUB U 09 03 35105 Serial Number (build sequence) U= Unit Week of Manufacture Year of Manufacture 09= 2009 10= 2010 etc. Model Number WMHC 1 018 B E H B T 01 F2 A C Y YY R UNY YYY Code 01-02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 YYY A Y YYY Y S Y Code 19 20 21 22 23 24 25 Code 01: Unit Type W= Water Source Heat Pump Code 02: Product Identifier MHC= Wall Mounted Console, Standard Range MHW= Wall Mounted Console, Geothermal Range Code 03: Design Series 1= Design 1 Code 04: Unit Size 015= 15000 BtuH Nominal Cooling 018= 18000 BtuH Nominal Cooling Code 05: Controls B= MicroTech III Unit Controller- Standalone C= MicroTech III Unit Controller w/ LonWorks Comm Module D= MicroTech III Unit Controller w/ BACnet Comm Module F= MicroTech III Unit Controller w/ BACnet-WSHP System Code 06: Voltage E= 208-230/60/1 J= 265/60/1 Code 07: Cabinet Height H= High Sill L= Low Sill Code 08: Return Air B= Bottom Return Air (High Sill) F= Front Return Air (Low Sill) Code 09: Discharge Air T= Top Discharge Code 10: Blower Motor 01= Standard Code 11: Cabinet Type /Discharge Grille 1st Digit- Cabinet Type A= Flat Top w/12 Extended End Pocket (High Sill) B= Slope Top w/12 Extended End Pocket (High Sill) F= Flat Top S= Slope Top 2nd Digit- Discharge Grille C= Chassis only 2= Standard Stamped Louver 3= Multi-Directional Grille (Plastic) Code 12: Cabinet Construction Type A= Standard 1/2 Fiberglass E= Indoor Air Quality (IAQ) 3/8 Code 13: Water to Refrigerant Heat Exchanger C= Copper Inner Tube/ Steel Outer Tube S= Cupro Nickel Inner Tube/ Steel Outer Tube Code 14: Heating Options 3= 3.5 kw Electric Heat Y= None Code 15: Dehumidification YY= None Code 16: Piping Hand L= Left Hand R= Right Hand Continued on next page. WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 5

Nomenclature Continued Code 17: Thermostat Control YYY= None R N L Options L= Low Limit Control M= Low Limit Control & Unit-mounted NSB Override Switch P= NSB Override Switch R= Remote Sensor Y= None Programmability N= Non- Programmable P= 7- Day Programmable w/lcd Display Y= None Controls R= Remote S= Wall Mounted Space Sensor w/nsb Override U= Unit Mounted T stat w/lcd Display W= Wall Mounted T stat w/fan Speed Switch Y= None Code 18: Always YYY Code 19: Always YYY Code 20: Refrigerant A= R410a Code 21: Power Connection C= Unit Mounted 20A Plug & Cord D= Unit Mounted 20A Plug & Cord w/ Fused Disconnect Switch E= Unit Mounted 20A Plug & Cord w/ Non-Fused Disconnect Sw Y= None Code 22: Cabinet Electrical 50V= 50VA Transformer 75V= 75VA Transformer YYY= None Code 24: Color Y= None Cabinet Grille Subbase S= Antique Ivory Oxford Brown Oxford Brown T= Antique Ivory Antique Ivory Oxford Brown B= Antique Ivory Antique Ivory Antique Ivory D= Cupola White Oxford Brown Oxford Brown P= Cupola White Cupola White Oxford Brown E= Cupola White Cupola White Cupola White G= Off White Oxford Brown Oxford Brown F= Off White Off White Oxford Brown H= Off White Off White Off White K= Putty Beige Oxford Brown Oxford Brown R= Putty Beige Putty Beige Oxford Brown L= Putty Beige Putty Beige Putty Beige V= Soft Grey Oxford Brown Oxford Brown J= Soft Grey Soft Grey Oxford Brown N= Soft Grey Soft Grey Soft Grey Cabinet Subbase 1= Antique Ivory Oxford Brown 2= Antique Ivory Antique Ivory 3= Cupola White Oxford Brown 4= Cupola White Cupola White Code 25: Outside Air Y= None Code 26: Agency Type Code 27: Packaging Code 28: Extended Warranty Code 29: Product Style (1= Style 1) Code 23: Water Flow Control H= 2-Way Motorized ½ Iso Valve, High Close-Off Press. N.C. P= 2-Way Motorized ½ Iso Valve, High Close-Off Press. N.C. & Supply, Return, Bypass Hand Valves & Measureflow Devices R= ½ Supply, Return & Bypass Valves Only W= 2-Way Motorized ½ Iso Valve, High Close-Off Press. N.C. & Supply, Return & Bypass Hand Valves Y= None WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 6

Electrical Legend Schematic Sym. C1 C2 CC CM COS CR DAT DCS DPG EWT FHS FSR FSS HP IOEXP LED1 LED2 LLS LWT MIII OVL R1 R2 RAT RV SLTS T1 TB1 UMT X1 Capacitor- Compressor Capacitor- Fan Contactor- Compressor Compressor Motor Sensor- Condensate Overflow Relay- Compressor Sensor- Discharge Air Disconnect Switch Drain Pan Ground Sensor- Entering Water Relay- Fan High Speed Relay- Fan Speed Switch- Fan Speed Switch- High Pressure I/O Expansion Board/Harness LED Annunciator/Harness LED Annunciator/Harness Low Limit Room Sensor Sensor- Leaving Waters MicroTech III Main Board Compressor Overload Protector Relay- Fan Motor Relay- Electric Heat Sensor- Room Air Valve- Reversing Sensor- Suction Line Temperature EG2UCP Terminal Strip Power Terminal Block Thermostat- Unit Mounted Transformer WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 7

Blower Fan Assembly Motor, Wheel, Fan Housing 300 280 205 Cabinet/Chassis components 100 015 018 Ref. No. Part Part Number 208-230V 265V 208-230V 265V Fan Assy Rework until 7/18 668958654 1 1 330 Fan Assy Rework 7/18 & later 910242642 1 1 Fan Assy Rework 668958655 1 1 N/S Capacitor, 2.5 MFD 440V until 10/16 668003109 1 1 1 1 Capacitor, 2.5 MFD 440V 10/16 & later 910181939 1 1 1 1 332 Fan Housing, Scroll 668793804 1 1 1 1 333 Fan, Tangential 667996503 1 1 1 1 334 Bearing Plate 668002701 1 1 1 1 N/S Cabinet/Chassis components 1 1 1 1 1 N/S= Not Shown. 1 Please contact Daikin with unit model and serial number for part numbers on Cabinet/Chassis components. WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 8

Refrigeration Circuit Compressor, Condenser, Evaporator, Switch & Valves Diagrams 92 859 75 Evaporator Coil/ TXV Detail Condenser Detail 750 205 66 71 67 65 64 70 69 Compressor Reversing Valve Piping 60 61 62 See Coremax Valve Assy Detail 63 137 482 110 Compressor Mounting Detail Low Temp Valve 480 160 TXV Bulb 151A 151B 151C Coremax Valve Assy Detail WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 9

Refrigeration Circuit Compressor, Condenser, Evaporator, Switch & Valves Components 015 018 Ref. No. Part Part Number 208-230V 265V 208-230V 265V Nut, Compressor Mount until 9/09 668383001 3 3 3 3 60 Nut, Compressor Mount 9/09 to 11/15 063060601 3 3 3 3 Nut, Compressor Mount 11/15 to 2/18 802012035 3 3 3 3 Acorn Nut, Compressor Mount 2/18 & later 910172114 3 3 3 3 Sleeve, Compressor Mount until 6/15 668955501 3 3 3 3 61 Sleeve, Compressor Mount 6/15 to 5/17 669543501 3 3 3 3 Sleeve, Compressor Mount 5/17 & later 910172106 3 3 3 3 62 Grommet, Compressor Mount 668955401 3 3 3 3 63 Plate, Compressor Mass 668793401 1 1 1 1 64 Gasket, Compressor Mount 668382901 1 1 1 1 65 Terminal Cover, Compressor Mount 668382801 1 1 1 1 66 Washer, Compressor Mount 668382701 1 1 1 1 67 Nut, Compressor Mount 668383001 1 1 1 1 Compressor 668951601 1 69 Compressor 668951603 1 Compressor 668951701 1 Compressor 668951711 1 Overload, Compressor 668015808 1 71 Overload, Compressor 668015810 1 1 Overload, Compressor 668015811 1 75 Condenser, COAX, Copper Inner Tube 668803401 1 1 1 1 Condenser, COAX, CUNI Inner Tube 668803402 1 1 1 1 Evaporator Coil, LH until 2/10 668959021 1 1 Evaporator Coil, LH 2/10 to 10/14 668959029 1 1 Evaporator Coil, LH 10/14 & later 668959038 1 1 Evaporator Coil, LH until 2/10 668959018 1 1 Evaporator Coil, LH 2/10 to 10/14 668959027 1 1 92 Evaporator Coil, LH 10/14 & later 668959036 1 1 Evaporator Coil, RH until 2/10 668959019 1 1 Evaporator Coil, RH 2/10 to 10/14 668959026 1 1 Evaporator Coil, RH 10/14 & later 668959039 1 1 Evaporator Coil, RH until 2/10 668959016 1 1 Evaporator Coil, RH 2/10 to 10/14 668959028 1 1 Evaporator Coil, RH 10/14 & later 668959035 1 1 N/S= Not Shown. Continued on next page. WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 10

Refrigeration Circuit Compressor, Condenser, Evaporator, Switch & Valves Components, Continued 015 018 Ref. No. Part Part Number 208-230V 265V 208-230V 265V Reversing Valve until 3/11 106694111 1 1 Reversing Valve 3/11 to 4/14 910110426 1 1 Reversing Valve 4/14 to 4/18 910124938 1 1 110 Reversing Valve 4/18 & later 910198409 1 1 Reversing Valve until 3/11 106694102 1 1 Reversing Valve 3/11 to 7/18 910110418 1 1 Reversing Valve 7/18 & later 910198406 1 1 Solenoid, Reversing Valve until 3/11 106694207 1 1 1 1 N/S Solenoid, Reversing Valve, 1.3 X 2.14 3/11 to 5/14 910110439 1 1 Solenoid, Reversing Valve 3/11 to 5/14 106694207 1 1 Solenoid, Reversing Valve 5/14 & later 910198415 1 1 1 1 High Pressure Switch until 7/11 106483301 1 1 1 1 137 High Pressure Switch 7/11 to 3/16 910117560 1 1 1 1 High Pressure Switch 3/16 & later 910171269 1 1 1 1 151A Seat, Fitting 668188801 2 2 2 2 151B Core, Valve 668188701 2 2 2 2 151C Cap, Valve 668189501 2 2 2 2 160 Fusible Plug, 283 F 106057401 1 1 1 1 859 Expansion Valve 668802901 1 1 Expansion Valve 106489102 1 1 840 Weight- Line 067009101 3 3 3 3 842 Weight- Line 060746901 1 1 1 1 N/S Drain Pan, Plastic 668802702 1 1 1 1 N/S Electric Heater- 3.5KW 667994908 1 1 1 1 N/S= Not Shown. WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 11

Control Box MicroTech III Controller Diagrams 150 80 80 190 190 120 100 120 100 250 250 208-230 Volt Unit Size 015 208-230 Volt Unit Size 018 80 120 190 250 100 200 265 Volt Units WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 12

Control Box MicroTech III Controls, Components 015 018 Ref. No. Part Part Number 208-230V 265V 208-230V 265V N/S Bracket, Capacitor 850010570 1 1 1 1 N/S Capacitor, Compressor, 35MFD 370V until 4/12 067291516 1 1 Capacitor, Compressor, 35MFD 440V until 4/12 067291515 1 1 Capacitor, Compressor, 35MFD 440V 4/12 & later 910120050 1 1 1 1 80 Main Controller, MicroTech III 668105601* 1 1 1 1 N/S I/O Expansion Board Assy until 8/12 668105701* 1 1 1 1 I/O Expansion Board Assy 8/12 & later 668105702* 1 1 1 1 100 Annunciator Assy, LED1 668395201 1 1 1 1 N/S Annunciator Assy, LED2 668395201 1 1 1 1 N/S Stand Off- PC Board 802028115 6 6 6 6 150 Contactor, Compressor, 208/230V until 3/13 073300102 1 1 Contactor, Compressor, 208/230V 3/13 & later 910140336 1 1 1 1 Contactor, Compressor, 24V 910140339 1 1 1 1 190 Relay, Fan, 3PDT 802005906 1 1 1 1 200 Relay, 24V, 30A until 3/13 106500101 2 2 2 2 Relay, 24V, 30A 3/13 & later 106500102 2 2 2 2 250 Transformer, 50VA until 4/11 060614102 1 1 Transformer, 50VA 4/11 & later 910116202 1 1 Transformer, 50VA until 4/11 060630702 1 1 Transformer, 50VA 4/11 & later 910116203 1 1 Transformer, 75VA until 4/11 667715902 1 1 Transformer, 75VA 4/11 & later 910116213 1 1 Transformer, 75VA until 4/11 667715901 1 1 Transformer, 75VA 4/11 & later 910116209 1 1 N/S Rocker Switch 061321501 1 1 1 1 N/S Switch, Momentary, N.O. 061377201 1 1 1 1 N/S N/S N/S TStat Retrofit Kit, 7-Day Programmable, Unit Mnt 910104352 1 1 1 1 LUI Keypad Thermostat Programmable 668811101 1 1 1 1 Thermistor 669529401 1 1 1 1 TStat Retrofit Kit, Non-Programmable, Unit Mnt 910104353 1 1 1 1 LUI Keypad Thermostat Non-Programmable 668811001 1 1 1 1 Thermistor 669529401 1 1 1 1 Control Temperature, Low Limit, +48 /+54 F 669521101 1 1 1 1 Control Temperature, Low Limit, +28 /+38 F 066540601 1 1 1 1 N/S Suction Line Temp (SLT) 910121227 1 1 1 1 N/S Air Temp Sensor (DAT) 107201601 1 1 1 1 N/S Water Temp Sensor (LWT) 107201601 1 1 1 1 N/S= Not shown on diagram. * When ordering this board, please provide the software part number printed on the board s label. See next page for Control Board Label Locations. WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 13

Control Box MicroTech III Controls MTIII Control Board Label Locations Label Label 668105701 668105901 Label Label 668105601 668105801 NOTE: When ordering the control board, please provide the software part number printed on the board s label. See above for label locations. WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 14

Field Installed Accessories Filters Qty Part Number Filter, Disposable, 9.75 X 29.25 High Sill 12-Pack 669521302 Filter, Disposable, 8.75 X 23.75 Low Sill 12-Pack 669521304 Manual Valves Size Box of 2 Box of 10 Combination Shutoff/Balancing Valve with Memory Stop 1/2" FPT 106065102 106065110 * Refer to IM 1151 for installing a motorized valve kit on MicroTech III units. Motorized Valves Kit * Actuator Body 2-Way Valve Kit, Normally Closed (NC), 1/2 NPT, 25 PSI 668996001 107179801 107210401 2-Way Valve Kit, Normally Closed (NO), 1/2 NPT, 25 PSI 668996002 107179810 107210401 2-Way Valve Kit, Normally Closed (NC), 1/2 NPT, 30 PSI 668996003 107179807 107210401 MicroTech III Communication Modules Part Number BacNet Comm Module Kit* 107293071 LonWorks Comm Module Kit* 107293070 * Kit includes comm module card, sensors, mounting tabs, and IM. MTIII H-8 Harness Assembly Kit Part Number MTIII, H-8 Output Wire Harness Assembly Kit 910107989 WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 15

* For sensors p/ns 910121754, 910152147, 910152149 or 910171464. ** For use with thermostats # 910121750. *** For use with thermostats # 910121746 & # 910121748. Field Installed Accessories Continued Thermostats & Sensors Part Number TStat, Wireless, 7 Day Programmable, Hi/Low Fan Speed 668898001 TStat, Wireless, Non-Programmable, Hi/Low Fan Speed 668898101 Programmable/ Non- Programmable, 2H/2C, AC, Touchscreen 910193126 Programmable/ Non- Programmable, 2H/2C, AC, Touchscreen, WIFI 910193131 Programmable, LUI, 2H/2C, 2-Speed Fan Control 668811301 Programmable/ Non- Programmable, LUI, 2H/2C, 2-Speed Fan, ACO, Touchscreen 910193093 Programmable/ Non- Programmable, LUI, 2H/2C, 2-Speed Fan, ACO, Touchscreen, WIFI 910193130 Wall, Stat- AC/DC, ACO, 7 Day Programmable, 2 Heat/2 Cool with Wall Plate 668375301 Wall, Stat- AC/DC, ACO, Non-Programmable, 2 Heat/2 Cool, NSB & OR with Wall Plate 668375401 Wall Stat: Programmable, 2 Heat/2 Cool, ACO, Hardwired 910121748 Wall Stat: Non- Programmable, 2 Heat/2 Cool, ACO, Hardwired 910121746 Remote ENF Temp Sensor for 668375301, 668375401 107096010 Wall Sensor for 910121746 & 910121748 667720401 TStat Guards Part Number TStat Guard 105571101 TStat Guard (10 Pack ) 105571110 Field Programming Transfer Cable Part Number Field Programming Transfer Cable 669917901 Relays Part Number MicroTech III to Mark IV Daisy Chain Adaptation for E to U 910151282 WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 16

Field Installed Accessories Continued Hoses Specification Part Number Hose Assy, Fire Rated Condensate 3/4" NPT X 2' 106063801 3/4" NPT X 3' 106063901 Hose Assy, Fire Rated Supply/Return 1/2" NPT X 9 668817701 1/2" NPT X 12 668817702 1/2 NPT X 18 668817703 1/2 NPT X 24 668817704 Hose Assy, Plastic Condensate 3/4" NPT X 30" 106063701 3/4" NPT X 36" 106665101 Outdoor Air Dampers for High Sill Units* Part Number Manual O.A. Damper 668816601 Motorized O.A. Damper Kit, 24V 910124326 * See IM 974-1. Subbase Kit Right Hand Left hand 3.5 Hi-Sill 910111375 910111374 7.0 Hi-Sill 106796206 106796205 1.0 Low-Sill 910111377 910111377 Water Piping Adapter Fittings Part Number 90 Elbow Kit 2 Pack 106066402 90 Elbow Kit 10 Pack 106066410 90 Elbow Kit 20 Pack 106066420 Elbow Only 061435301 Straight Adapter Kit 2 Pack 669522202 Straight Adapter Kit 10 Pack 669522210 Straight Adapter Kit 20 Pack 669522220 Adapter Only-.625 x 1/2 FPT 041116213 Fused Disconnect Kit Kit Fuse P/N Fuse, 265V, 10A 668817303 4EHG7795 Fuse, 208/230V, 10A 668817203 4EHG7795 Fuse, 208/230V, 15A 668817201 049128306 WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 17

Part Number Kit Field Installed Accessories Continued MicroTech III Temperature Sensors Tennant Override Setpoint Adjustment Status LED Note: Can only be used in conjunction with a communication (Comm.) card. See OM 931 for required jumper settings. Fan & Mode Switch 669088101 669529001 Yes No No No 668900801 669529101 Yes 55 to 95 F (12 to 35 C) Yes Yes 669088201 669529201 Yes -3 to +3 F (-1.5 to 1.5 C) No Yes * IM 1084-2 is included in Kit. ** Kit components listed below. MicroTech III Unit Control Accessories ** Multiple Unit Control Panel: Allows a master unit controlled by a T Stat, to operate up to 3 secondary units Not Recommended for use with a Boilerless System Kit. Part Number 056794201 Boilerless System Kit with I/O Expansion Board * 910110355 Boilerless System Kit without I/O Expansion Board 910110353 Multiple Unit Control Panel Kit 310 310 311 313 Ref. No. Part Number Qty. 310 Cover, Control Box 106436101 1 311 Circuit Board 056794001 1 312 Stand Off, Circuit Board 802028090 6 313 Box 850007827 1 312 WSHP; WMHC,WMHW 015, 018 Design 1 Rev. R 11/18 RPL 7000131 / Page 18

Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! Daikin Enfinity Console WSHP McQuay Enfinity Console WSHP WMHC, WMHW 015, 018 Design 1 Critical Components Unit Sizes Voltage Part Number Control Control Board, MicroTech III ALL ALL 668105601 Compressor Compressor 015 208-230/60/1 668951601 Compressor 015 265/60/1 668951603 Compressor 018 208-230/60/1 668951701 Compressor 018 265/60/1 668951711 Blower Fan Assy Fan Assy, Rework ALL 208-230/60/1 668958654 Fan Assy, Rework ALL 265/60/1 668958655 Fan Housing & Wheel Fan Housing ALL N/A 668793804 Wheel, Tangential ALL N/A 667996503 Sensor Suction Line Temp Sensor (SLTS) ALL N/A 910121227 Air/Water Temp Sensor ALL N/A 107201601 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call 1-800-37PARTS 7000131 Rev. R 11/2018 CPL Page 1 of 1