When you think safety think Systemair

Similar documents
Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

IS (Intrinsic safety) - Ex (Epsilon x) ATEX CENELEC

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Healthcare

Dual certification! Air handling units for potentially explosive atmospheres

Roof Fan DVG EC. Smoke extraction and daily ventilation in one!

Roof Fan DVG EC. Smoke extraction and daily ventilation in one!

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

Vacuum Hose Reel 881 Ex

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

OPTIBAR DP 7060 Supplementary Instructions

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Beamex Calibration White Paper. Calibration in hazardous areas

ANNEX GD-CERT-EX-EN SIT

TUNNEL FANS STANDARD AND HOT SMOKE

Beamex. Calibration White Paper. Calibration in hazardous areas

Part No KEMPER Filter-Master XL

Welcome to Systemair!

ATEX Vacuum Pumps in Accordance with the Directive 94/9/EG (ATEX 95) Technical Information

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

NOVENCO BUILDING & INDUSTRY PRODUCTS. Products

TRASCO ATEX Couplings

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

SOUND-INSULATED FAN. Iso-K OPERATION MANUAL. Iso-K_v.1(2)-EN.indd :20:59

Explosion-protected actuator Page 259 of 292

We work hard to gain your trust

Airo Wireless Intrinsically Safe White Paper. Written By: David Schmitt

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

HAZARDOUS AREA CLASSIFICATION AND SELECTION OF EQUIPMENT FOR SAFE USE THEREIN FROM AN ELECTRICAL VIEWPOINT

AIR HANDLING UNITS MANDÍK

INSTRUCTION MANUAL (ATEX / IECEx)

Centrifugal Fans, Non-Overloading, Backward Inclined

Weighing Solutions for Hazardous Areas FULL COMPLIANCE WITH ATEX DIRECTIVE

Pure competence in air. NOVENCO BUILDING & INDUSTRY PRODUCT BROCHURE

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

Air Sensor. SAC Ex FCS Ex. Manual ATEX. AQ M-Tech AB

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

more than just a fan supplier more than just a fan supplier Axair Fans UK Limited

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

HYTEK ATEX APPROVED BUND ALARM

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Office

Technical Ventilation

Topvex SR03, SR04, SR06 Compact Air Handling Unit

Fire dampers. For diverse applications

AZN ATEX INSTALLATION AND MAINTENANCE

[ TECHNOLOGY ] and does this definition affect a burner.

VERSAFLOW VORTEX Supplementary instructions

VSD AND SS DRIVING ATEX MOTORS February 2014

K Series CK-25 N CK-35 N CK-40 F CK-50 CK-60 F ECO-500 KITCHEN EXTRACTORS. Kitchen extractors CK

Manual Power relay SR853

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator School

Ex Products Highest level of safety under the most difficult conditions

Novenco jet fans. AUO / ARO / AUT / ART / CGF January 2010

Systemair product news - Fans NEWS

ATM Lighting sp. z o.o

Green Ventilation Jet Fan Systems for Car Parks

General technical information: fans

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

ATEX - Implications for manufacturers

ATEX Safety Switches. More than safety.

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

manual addendum DELPHI Ex

Safety instructions VEGAPULS 64

AXIS-QA G TUBO-M/MZ AXIAL FANS. Axis / Tubo OPERATION MANUAL

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Certificate of Compliance

SVK2 EX SVK2 SVV2 SVH2 ROOF FANS

Safety instructions VEGADIF DF65.GX*****H/Z/P/F***** IECEx BVS

Type FK-EU FOR DIVERSE APPLICATIONS. Homepage > Products > Fire and Smoke Protection > Fire dampers > Type FK-EU

1. GENERAL TECHNICAL INFORMATION

4) Intrinsic Safety Certification

Use and Maintenance Manual. WPA-E-N/Ex. II 2 G c Ex e II T3. ATEX marking: Explosion proof stand fans WPA-E-N/Ex

SmartDial. Wireless. User Manual. -en_gb language A004. Document in original

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

ROOFMASTER STEF-HT ROOF FAN

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N

OPTIWAVE X500 Supplementary Instructions

Annubar Flowmeter Series

Translation of the assembly instructions with operating instructions and technical appendix

Materials Handling and Intralogistics. Industrial Trucks. In accordance with the Directive Equipment for potentially explosive atmospheres (ATEX)

Jet Fan Types AUC/ARC/AUR/ARR/AUO/ARO Installation and Maintenance

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Introduction to Fans. The Basics of Fan Principles and Terminology

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

Implementation of ATEX Guidelines

SAFETY INSTRUCTIONS. euromotori. Safety Instructions electric motors LEX series

OPTIBAR P 1010/2010 C Supplementary instructions

F17W44_MFB_F_EN INSTALLATION INSTRUCTIONS

Manual Isolating Barrier D461R1 (Revision 01)

SMOKE CONTROL - NEW DIRECTIONS

INSTRUCTION MANUAL (ATEX / IECEx)

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Transcription:

Smoke extract- and ATEX-fans When you think safety think Systemair www.systemair.com

Smoke and heat extraction Certification test of axial fan HA, (above) and centrifugal roof fan DVV The smoke and heat resulting from fires are dangerous to people. High temperatures contribute to the spreading of fire by pre-heating areas not yet burning and increasing the risk of flash over. Buildings need to be designed in a way that in the event of a fire the spreading of smoke and fire is limited.this will facilitate the rescue of people and animals and make it possible for the fire brigade to effectively fight the fire. Mechanical smoke and heat extraction systems reduce the risk factors by removing smoke and heat in the event of a fire. It is especially important in the following cases: Rooms without windows or below ground level Areas influenced by wind Rooms with high demand for cleanliness, thus airtight. Mechanical extraction systems are independent from external conditions and have instant full capacity, i.e. full air volume is available directly. Mechanical smoke and heat extraction systems are today an essential part of preventative fire protection measures. Centrifugal fans and axial fans We have three types of smoke extract fans centrifugal roof fans wall/duct mounted centrifugal fans axial fans. Our smoke extract fans are certified for dual purpose application, i.e. smoke extraction as well as daily normal ventilation.the 2 axial fans HA and AXC and the centrifugal fans WVI can be installed within the fire zone. Applications Systemair offers following temperature classifications: F600 600 C/2h F C/2h F300 300 C/2h Mechanical smoke and heat extraction for shopping malls, airports, industrial buildings, cinemas, etc. For high temperature process air Car park exhaust Catering and kitchen canopies Jet fans Our fans are certified Systemair smoke extract fans are certified in accordance with EN12101-3, at the Technical University of Munich, Germany. Our fans are CE-labelled. EU-declaration of conformity in accordance with DIN EN 12101-3, TÜV-Süd, Munich 2002-06, can be downloaded from our homepage. www.systemair.com Certification test of axial fan

Axial fans up to wheel diameter 1 mm HABV-G (inlet with guide vanes) HABV (with inlet guide vanes) HA...(B)-G F300 HA...(F)-G F HABV-G F600 Two high temperature smoke extract fans in series, same rotation direction F600 version with capsulated motors with cooling ducts In case one fan is switched off or stops running for any reason, approx. 65% of the total air volume will be supplied. HABV...F600 (with inlet guide vanes) Fan wheel diameter from to 1 mm F600 version with capsulated motors with cooling ducts 300 C C 600 C 600 C 1. 1. max. 2.700 Pa static 1. max. Pa static max. 2.000 Pa static max. Pa static max. 3.000 Pa static max. 2. Pa static max. Pa static max. 700 Pa static max. 1.070 Pa static max. 1.940 Pa static max. 1. Pa static max. 1.140 Pa static max. 950 Pa static max. 3.000 Pa static max. 850 Pa static max. 720 Pa static max. 570 Pa static max. 430 Pa static max. 2.200 Pa static max. 350 Pa static max. 1.840 Pa static max. 1.460 Pa static max. 1.160 Pa static max. 920 Pa static max. Pa static max. 600 Pa static max. Pa static max. 750 Pa static max. 250 Pa static 0 50 100 150 200 250 Volume flow x 10 3 [m 3 / h] 0 50 100 150 200 250 Volume flow x 10 3 [m 3 / h] Accessories Silencers Protection guards Back draugh dampers Counter flanges Mounting feet, alternatively mounting brackets Flexible connections Inlet cones RSA SG-AW/AR LRK GFL-AR MFA-AR EVH ESD 3

Axial fans HA HA 300 C C 1. max. 1.200 Pa static max. Pa static max. 700 Pa static max. 1.050 Pa static max. Pa static max. 640 Pa static max. 510 Pa static max. 415 Pa static max. 310 Pa static max. 850 Pa static max. Pa static max. 610 Pa static max. 550 Pa static max. 420 Pa static max. 375 Pa static max. 300 Pa static 0 50 100 150 200 250 Axial fan HA...(B) F300 HA...(F) F s to 1 mm P-HA with square wall plate with inlet cone, manufactured from steel, hot dip galvanized, up to size 1000 Axial roof fan HA...(B)-D F300 HA...(F)-D F HABV...-D F600 s to 1 mm With roof cowl and base frame Volume flow x 10 3 [m 3 / h] HA...(B)-D AXC 1250 1000 max. 1.300 Pa static max. 750 Pa static max. 600 Pa static max. Pa static max. Pa static max. Pa static max. 950 Pa static max. 750 Pa static max. 600 Pa static AXC...(B) F300 AXC...(B)-G F300 Fan wheel diameter from to 1250 mm Adjustable aluminium impellers max. Pa static max. 350 Pa static max. 300 Pa static V air in m³/h 0 15.000 30.000 45.000 60.000 75.000 90.000 105.000 120.000 135.000 150.000 1250 1000 max. 1.200 Pa static max. 2.150 Pa static max. Pa static max. 1.300 Pa static max. Pa static max. 780 Pa static max. 660 Pa static max. Pa static max. 1.100 Pa static max. 840 Pa static max. 2.600 Pa static max. 2.600 Pa static V air in m³/h 0 15.000 30.000 45.000 60.000 75.000 90.000 105.000 120.000 135.000 150.000 165.000 AXCG s from to 1250 mm Casing manufactured from steel, hot dip galvanised 4

Centrifugal roof fan up to 52 m 3 /h DVV F/F600 Roof fan The motor is separated from the air stream and insulated. ISO class F, protection class IP 54. Backward curved centrifugal impellers, in C version made from galvanized steel, in stainless steel in 600 C version. Motor cooling via cooling duct in a negative pressure system.the terminal box is fitted outside the cooling duct. DVV fans are also available in versions for 40 C and 100 C continuous operation. C 600 C max. 2.000 Pa static max. 1.550 Pa static max. 1.200 Pa static max. 650 Pa static max. 550 Pa static max. 350 Pa static 0 9.000 18.000 27.000 36.000 45.000 55.000 Air volume [m 3 / h] Volume flow x 10 3 [m 3 /h] Accessories Back draught damper Back draught damper with inlet cone Bellmouth inlet Inlet flange flexible inlet connection Flat roof socket Flat roof socket Inlet silencer Inlet silencer Outlet silencer Adapter for SSV VKV/F VKVE/F ESDV ASSV/F ASFV FDV/F FDVE/F SSV/F SSVE/F HSDV/F ASK/F Centrifugal wall fans WVA/WVI up to 40 000 m 3 /h WVA WVI Centrifugal fan for wall mounting. Casing from galvanized steel, powder coated. Backward curved centrifugal impellers, in C version made from galvanized steel, in stainless steel in 600 C version. WVA to be installed outside the fire zone, WVI with insulated motor to be installed inside the fire zone, with cooling duct ZHZ to be connected to the motor compartment. Fans are certified for horizontal installation on a wall, motor pointing downwards. Possibility to connect to a duct system, using accessory SN (inlet duct connection). IN outlet connection with protection guard is used for WVI as duct connection through the wall, for WVA as rain protection. C 600 C Accessories Flexible connection max. 850 Pa static max. Pa static max. 1.200 Pa static max. 810 Pa static max. 610 Pa static max. Pa static 0 9.000 18.000 27.000 36.000 40.000 Air volume [m 3 / h] Inlet cowl Outlet cowl Cooling duct Console EPIN/EPSN SN IN ZHZ WBK-W 5

ATEX safe ventilation in potentially explosion hazardous environment EX140/180 KTEX DKEX RVK High demands for fans approved for Zone 1 From 1 July 2003 the new ATEX directive 94/9/EC was in force in the whole of the European Union for equipment to be used in potentially explosive atmospheres such as petrol stations, battery charging rooms, chemical industry, fume cupboards and spray cabinets. Approved for Zone 1 category 2G Can be speed controlled Approved for Explosion group IIA, IIB and IIC What separates ATEX fans from standard fans is mainly that they meet considerably higher quality demands they are produced from materials that do not give off sparks the temperature does not exceed the limit for Temperature class T3 they are traceable. They must be marked with machine plate made from metal. *) Temperature Ignition temp. Max. surface temp. of classification of medium electrical equipment T1 > C C T2 >300...> C 300 C T3 >200...>300 C 200 C T4 >135...>200 C 135 C T5 >100...>135 C 100 C T6 >85...>100 C 85 C The selection of an explosion proof fan Systemair provides you with helpful information for the selection of a suitable fan. Please bear in mind that manufacturers are responsible only for the appearance and workmanship of the fan.the system user is responsible for the correct system design for a proper operation. Pre-selection depends on the medium to be transported. Each medium has an individual ignition temperature.the fans supplied by Systemair comply with temperature classification T3, some units can also be used in T4. *) The next step is the selection of the correct zone resp. category. Basically the correct zone or category can only be given by the user of the system, after having conducted an analyse regarding the occurrence of explosion hazardous gases or gas mixtures in the project. All Systemair explosion proof fans are in unit category II, allowing an application in zone 1 and zone 2. In the industry, explosion hazardous areas are classified in zones. ATEX classifies the fans in categories, corresponding to the zones. Categories are independent from the substance causing the explosion hazard.the classification in categories (or zones) is related to the temporal appearance (frequency of occurrence) of explosion hazardous atmosphere (gas/vapour/fog-air mixture in ignitable condition).the categories/zones do not define the concentration! Category 1 (zone 0) covers areas, where there is a permanent or long lasting occurrence of explosion hazardous atmosphere (more than 1000 h/year). Example: inside a fuel tank. Category 2 (zone 1) covers areas, where there is a regular occurrence of explosion hazardous atmosphere (10-1000 h/year). Example: Filling machine Category 3 (zone 2) covers areas, where there is a non-regular or short time appearance of explosion hazardous atmosphere (up to 10 h/year). Example: defective gas pipe, accidents. Typical examples for application of ignition protection classes: i d e p o m q Intrinsically safe Flame proof Increased safety Pressurized Oil filled Encapsulated Sand filled Tested and approved Systemair Atex products: Fans tested in accordance with ATEX directive 94/9/EC and EN 14, 19 and EN1127-1 Ex(e) increased safety Ex(d) flame proof (pressure resistant capsulation, DVV-ex) Windings with integrated thermal motor protection, with external leads, to be connected to certified motor protection devices All models have serial numbers on the metallic rating plate. 6

AWEX DVEX DVV-EX EX 140/180 Air flow up to 1180 m 3 /h (0.33 m 3 /s). Ex(e) increased safety. Motor protection device MSEX available for EX140 and EX180. 230V and V models available. RVK Air flow up to 1020 m 3 /h (0.28 m 3 /s). Ex(e) increased safety. Casing consists of conducting plastic. Ex-classified terminal box available as accessory. Motor speed controllable by transformer. DKEX Air flow up to 5.000 m 3 /h (1.4 m 3 /s). Ex(e) increased safety. Motors speed controllable by transformer. KTEX Air flow up to 5.000 m 3 /h (1.4 m 3 /s). Ex(e) increased safety. Ex-classified terminal box available as accessory. Motors speed controllable by transformer. AWEX Air flow up to 11. m 3 /h (3.19 m 3 /s). Ex(e) increased safety. s and 420 are approved for temperature class T4. Ex-classified terminal box available as accessory. Motors speed controllable by transformer. DVEX Air flow up to 8.600 m 3 /h (2.4 m 3 /s). Ex(e) increased safety. Motors speed controllable by transformer. Ex-classified terminal box available as accessory. DVV-EX Air flow up to 44.000 m 3 /h (12.2 m 3 /s). Ex(d) flame proof. Motors speed controllable by frequency inverters. Supplied with Ex-classified terminal box pre-installed at the fan casing. Art no. Model ATEX certificate no. 1 EX 140-4 Centrifugal Fan (ATEX) SP03ATEX3101X 1562 EX 140-2 Centrifugal Fan (ATEX) SP03ATEX3101X 1561 EX 180-4 Centrifugal Fan (ATEX) SP03ATEX3101X 1557 EX 140-4C Centrifugal Fan (ATEX) SP03ATEX3101X 1559 EX 140-2C Centrifugal Fan (ATEX) SP03ATEX3101X 1558 EX 180-4C Centrifugal Fan (ATEX) SP03ATEX3101X 1564 KTEX 50-25-4 Rect.fan (ATEX) SP04ATEX3105X 3958 KTEX 50-25-4 (230V/3~) (ATEX) SP04ATEX3105X 1566 KTEX 50-30-4 Rect.fan (ATEX) SP03ATEX3103X 3957 KTEX 50-30-4 (230V/3~) (ATEX) SP03ATEX3103X 1568 KTEX 60-30-4 Rect.fan (ATEX) SP04ATEX3107X 1570 KTEX 60-35-4 Rect.fan (ATEX) SP04ATEX3109X 1572 KTEX 70-40-6 Rect.fan (ATEX) SP04ATEX3111X 3965 DKEX 225-4 Centrifugal (ATEX) SP04ATEX3106X 3959 DKEX 225-4(230V/3~) (ATEX) SP04ATEX3106X 3966 DKEX 250-4 Centrifugal (ATEX) SP03ATEX3104X 3986 DKEX 250-4(230V/3~) (ATEX) SP03ATEX3104X 3967 DKEX 280-4 Centrifugal (ATEX) SP04ATEX3108X 3968 DKEX -4 Centrifugal (ATEX) SP04ATEX3110X 3969 DKEX -6 Centrifugal (ATEX) SP04ATEX3112X 1680 DVEX D4 Roof fan ATEX SP04ATEX3113X 2040 DVEX D4 230V 3~Roof fan ATEX SP04ATEX3113X 1681 DVEX D4 Roof fan ATEX SP04ATEX3114X 1682 DVEX D4 Roof fan ATEX SP05ATEX3115X 1683 DVEX D4 Roof fan ATEX SP04ATEX3116X 1684 DVEX D6 Roof fan ATEX SP04ATEX3117X 1685 DVEX D6 Roof fan ATEX SP05ATEX3118X 1686 DVEX D6 Roof fan ATEX SP04ATEX3119X Art no. Model ATEX certificate no. 5969 AW D4-2-EX Axial fan ATEX ZELM05ATEX0279X 5970 AW 420 D4-2-EX Axial fan ATEX ZELM05ATEX0279X 5971 AW 550 D6-2-EX Axial fan ATEX ZELM05ATEX0279X 5972 AW 650 D6-2-EX-Axial fan ATEX ZELM05ATEX0279X 30271 RVK Y4 (ATEX) ZELM03ATEX0198X 30841 DVV-EX D4 Roof fan 40 SIQ06ATEX062X 30842 DVV-EX D4-6 Roof fan 40 SIQ06ATEX062X 30843 DVV-EX D4-8 Roof fan 40 SIQ06ATEX062X 30844 DVV-EX D6 Roof fan 40 SIQ06ATEX062X 30845 DVV-EX D6-8 Roof fan 40 SIQ06ATEX062X 30846 DVV-EX D8 Roof fan 40 SIQ06ATEX062X 30852 DVV-EX D4 Roof fan 40 SIQ06ATEX062X 30848 DVV-EX D4-6-K Roof fan 40 SIQ06ATEX062X 30853 DVV-EX D4-8 Roof fan 40 SIQ06ATEX062X 30849 DVV-EX D4-8-K Roof fan 40 SIQ06ATEX062X 30847 DVV-EX D4-K Roof fan 40 SIQ06ATEX062X 30854 DVV-EX D6 Roof fan 40 SIQ06ATEX062X 30855 DVV-EX D6-8 Roof fan 40 SIQ06ATEX062X 30851 DVV-EX D6-8-K Roof fan 40 SIQ06ATEX062X 30850 DVV-EX D6-8-K Roof fan 40 SIQ06ATEX062X 30856 DVV-EX D6 Roof fan 40 SIQ06ATEX062X 30857 DVV-EX D6-8 Roof fan 40 SIQ06ATEX062X 30860 DVV-EX D6-8-K Roof fan 40 SIQ06ATEX062X 30859 DVV-EX D6-K Roof fan 40 SIQ06ATEX062X 30858 DVV-EX D8 Roof fan 40 SIQ06ATEX062X 30861 DVV-EX D8-K Roof fan 40 SIQ06ATEX062X 30862 DVV-EX 1000D6 Roof fan 40 SIQ06ATEX062X 30863 DVV-EX 1000D8 Roof fan 40 SIQ06ATEX062X 7

Systemair AB SE-739 30 Skinnskatteberg, Sweden Tel +46 222 440 00 Fax +46 222 440 99 mailbox@systemair.se www.systemair.com Systemair Inhouse Studio September 2006 E8038