Single Channel Video Receive Unit with two Bi-directional Data Channels and one Bi-directional Alarm Channel for a Multimode Fibre Link

Similar documents
Dual System with 2x Independent Channels each of :

Single Channel Video Transmit Unit with one Bi-directional Data Channel and two Uni-directional Alarms for a Multimode Fibre Link

Four channel video link For low cost video transmission

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

ACCURATE ELECTRONICS INC

VPS3 Installation Manual

21-light Remote Annunciator. Owner s Manual

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

ADDENDUM. xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION GENERAL APPLICATION INFORMATION

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

INSTALLATION INSTRUCTIONS

C-Bus Four Channel General Input Unit Installation Instructions

USER MANUAL FOR OPERATING SYSTEM

VDS2510 Installation Manual

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

RS485 MODBUS Module 8AI

General Routing Interface

Instruction Manual Model Backup Switch, 1 for 8

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

Fratech Multipath-IP

KT-100 Door Controller

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

5000 INSTALLATION GUIDE

LCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

Instruction Manual Model L2 RF Switch

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

NT DUAL CHANNEL DISPLAY. User Guide

600 Range Dialer Installation Manual. Version 1.0

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

IF-L/RF Protection Switch

T3/E3 Fiber Optic Line Drivers

OVEN INDUSTRIES, INC.

HRX Technical Manual. Version 1.2

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

OFS IV Optical Fibre System

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

P2267 NETWORK INTERFACE

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

FEC400 Series. Installation Manual

How to use the BTRM in Remote Enclosures

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

4120 Fire Alarm Network Reference

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

M2500 Engine Controller Installation Manual

Instructions R8471J Gas Controller for use with Model OPECL Open Path Eclipse IR Gas Detector 1.1 1/

Booster Power Supply Manual

Advanced DIGITAL Wired PIR Motion Detector

Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C

D3000. Installation & Setup Guide

Analog Annunciator Unit SACO 16 A3. Product Guide

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

LCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

STATUS ALARM HISTORY ALARM RESET

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

SCR100 User Manual. Version:1.1 Date:Dec 2009

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Series Digital Controller Instruction Sheet

S INTRUSION&FIRE ALARM AND ACCESS CONTROL PANEL

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

Installation and user manual for the BiWire / Conventional Repeater Panel

DESCRIPTIVE AND INSTALLATION INSTRUCTION MANUAL FOR MODEL G1000 AND H1000 SERIES ANNUNCIATORS

7EF/7HF/7EC/7ES Temperature Controllers

SIMATRIX NEO Modular Video Matrix

LCP-10G3B4HDR(T)-G. 10GBASE-LR Lite SFP+ Optical Transceiver. Description. Applications. Performance FEATURES. RoHS compliance

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

ESSEX ENGINEERING CORPORATION

InBio X60 Series Access Control Panel User Manual

GDC 087R Issue 1 - May Installation and Operation UAS Network/Dropside Interface Unit Model NIU/DIU 7624.

Masthead Repeater Installation Handbook

4 Channel Contact Closure SFP DIN Fiber Link System

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

HGM300/RDM800 PREVENTATIVE MAINTENANCE AND TECHNICAL SUPPORT. SECTION 1 HGM300 CPU reset, RDM800 CPU reset, WARM UP notes and HGM300 Self Test

LC1350 Level Controller

Fibre Optic Basics FIA Summer Seminar 2014

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

Orion ISS. Intrusion and Fire Alarm Panel. Signal-10. User s Manual

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

WP4086 Condition Monitoring System

EOTec 2C32 Installation Guide

I/A Series 716C 1/16 DIN Temperature Controller

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Transcription:

AMG5614A3 Instruction Manual Single Channel Video Receive Unit with two Bi-directional Data Channels and one Bi-directional Alarm Channel for a Multimode Fibre Link The AMG5614A3 is a standalone one channel video receive unit designed to receive 1 video signal and transmit & receive 1 RS485/RS232/RS422 data signal and 1 20mA current loop data signal plus 1 Bi-directional alarm over a single Multimode optical fibre. The AMG5614A3 is designed to be powered using an AMG2001 standalone power supply. The AMG5614A3 is designed to operate with an AMG5613A3 / AMG5613A3R single channel transmit unit in a point to point configuration. The R suffix in the partno. indicates a rackmount configuration. Page 1 of 12

Contents Introduction 3 Unit Functional Schematic... 3 Optical Connection... 3 Connections 4 Video Output Connections... 4 Optical Connections Multimode... 4 Power Connection... 4 Data and Alarm Channel Connections... 4 Front Panel Indicators 5 Power LED... 5 Low Speed Data LEDs... 5 Auxiliary Data LEDs... 5 Alarm LEDs... 5 Data and Alarm Channel Configuration 6 Data Channel Configuration... 6 Data Interface Connections... 7 Alarm Channel Configuration... 7 Alarm Interface Connections... 7 Auxiliary 20mA Current Loop Data Channel Configuration 8 Data Interface Connections... 8 Physical Information 9 Dimensions... 9 Mounting Details... 9 Safety 9 Maintenance and Repair 9 Page 2 of 12

Introduction Unit Functional Schematic The AMG5614A3 receives 1 video signal plus 2 data and 1 bi-directional alarm signal from a AMG5613A3 transmit unit. It also transmits 2 data and 1 bi-directional alarm signal to a AMG5613A3. Optical Connection The AMG5614A3 connections are illustrated in the following example which shows an AMG5613A3 transmit unit together with an AMG5614A3 standalone receive unit configured as a single channel point to point system. Page 3 of 12

Connections Video Output Connections No. of channels...1 Connectors...75 ohm BNC Socket. Output Impedance...75 ohm terminated. Output Level...1 Volt p-p nominal Frequency Response...10Hz to 7MHz. Optical Connections Multimode No. of Optical Connections...1 per video channel Optical Fibre...Multimode 50/125 or 62.5/125** Connector...SC/PC Minimum Optical Launch Power...-10dBm Transmit Wavelength...1550nm Minimum Optical Sensitivity...-30dBm Receive Wavelength...1310nm Minimum Optical Dynamic Range...20dB. **Note: the transmission distance is limited by the bandwidth of the Multimode optical fibre. The optical data rate is 155Mbits/s, which may restrict operation to a maximum fibre length of 7km, although in most cases the units will operate successfully over longer fibre lengths. It is advisable however for distances greater than 7km, to have the optical fibre tested. Power Connection Connector Type...Removable 2-pin, 3.81mm, Screw Terminal Connector Partno...Phoenix 1803578 Supply Voltage...+12 to +15 Volts DC Maximum Power...1.5 Watts Data and Alarm Channel Connections No. of Integral Data Channels...1 Selectable RS-232 / RS-422 / RS-485 No. of Aux. Data Channels...1 20mA No. of Alarms...1 Connectors...Removable 5-pin, 8-pin, 2.5mm, Spring Terminal Connector Partnos...Phoenix 1881354, 1881383 Integral Data Interfaces RS-232, RS-422 or R-S485. Selected by slide switch inside enclosure. *See appropriate section on how to remove the case for access to the data switches RS-485 Switch Position - Top RS-422 Switch Position - Middle RS-232 Switch Position - Bottom Alarm Input...Contact Closure pull-up is 330R to +3V3 Alarm Output...Solid-state Relay, maximum 150mA at 125Vac/dc, Ron < 6.5Ω Page 4 of 12

Front Panel Indicators Power LED Power / Video / Opto...Green - Video present & opto sync. R/G - Opto sync. but no video present. Red - No opto sync. Off - No power applied to unit. Low Speed Data LEDs Data Present IN (RS485 or RS422)...Green - logic zero (+V, -V) present on IN+, IN- Red - logic one (-V,V+) present on IN+, IN- Off - tri-state off or no connection on IN+, IN- Data Present IN (RS232)...Green - logic zero (+V) present on input IN+ Red - logic transitions present on input IN+ Off - logic one (-V) present on input IN+ IN corresponds to the data signals being transmitted onto the optical fibre. Data Present OUT (RS485 or RS422) Green - logic zero (+V,-V) present on OUT+, OUT- Red - logic one (-V,+V) present on OUT+, OUT- Off - tri-state off or no connection on OUT+, OUT- Data Present OUT (RS232)...Green - logic zero (+V) present on OUT+ Red - logic transitions present on OUT+ Off - logic one (-V) present on OUT+ OUT corresponds to the data signals being received from the optical fibre. Auxiliary Data LEDs Data type depends on AMG system: RS-232, RS-422, RS-485, 20mA,TTL, or FTT-10A Data Present IN...Green - Data channel present but not transmitting R/G - Data channel transmitting Off - Data channel not present or no connection IN corresponds to the data signals being transmitted onto the optical fibre. Data Present OUT...Green - Data channel present but not transmitting R/G - Data channel receiving Off - Data channel not present or no connection OUT corresponds to the data signals being received from the optical fibre. Alarm LEDs ALARM IN...Green - Alarm ON / Contacts closed. Off - Alarm OFF / Contacts open. ALARM OUT...Green - Alarm ON / Contacts closed. Off - Alarm OFF / Contacts open. Page 5 of 12

Data and Alarm Channel Configuration The AMG5614A3 sends and receives data to/from a AMG5613A3 single channel standalone transmit unit. The physical data interface RS-485, RS-422 or RS-232 is individually selectable by the user with the corresponding slide switch mounted on the main PCB inside the enclosure. One bi-directional alarm is also provided. The alarm input is typically connected to a contact closure switch. The alarm output can receive an on/off signal from an AMG5613A3 and is typically used to convey contact closure status. Data Channel Configuration Each low speed data channel provides an RS-232, RS-422 (full duplex, four wire) or RS-485 (half duplex, two wire) interface defined by the corresponding mode switch inside the enclosure. Every data channel as shipped from the factory is set up for RS-485 operation unless otherwise requested. The data input for both the RS-485 and the RS-422 modes detects a tri-state input condition by monitoring the differential voltage level across the input. A differential level below 600mV positive or negative will be detected as a tri-state condition. A level above 600mV positive or negative will be detected as a logic 1 or logic 0 respectively. It is important therefore to terminate the RS-485 bus or the RS-422 input bus using 120Ω if a pre-bias is present on the RS-485 or RS-422 bus. A large number of third party equipment manufacturers apply a pre-bias on their RS-485 bus. This prebias is applied by pulling one arm of the RS-485 bus high (+5 volts) and the other arm low (0 volts) using high value resistors within the third party equipment. In order to ensure that the AMG equipment detects a tri-state condition, then these resistors should have a value above 5kΩ. If the third party bias resistors are less the 750Ω the bus can be multiple terminated as required to ensure that a tristate level is detected. Page 6 of 12

The system detects a tri-state input condition on the data channel bus when in RS-485 or RS-422 mode. Data Interface Connections Data Channel Connector Pin No. 1 RS-422 [switch middle] IN + (A) 2 IN - (B) 3 RS-485 [switch top] GND GND 7 IN/OUT + (A) OUT + (A) 8 IN/OUT - (B) OUT - (B) RS-232 [switch bottom] IN GND 4 5 6 OUT Note: (A) or (B) in brackets in the above table refers to RS-485 / RS-422 data specification. Alarm Channel Configuration The AMG5614A3 provides one bi-directional alarm output / contact closure input per video channel. The alarm input is typically connected to a contact closure switch. An ALARM IN+ input incorporates a 330R pull-up resistor to the internal +3V3 supply. The alarm output can receive an on/off signal from an AMG5613A3 and is typically used to convey contact closure status. An alarm output uses a solid-state relay, with a maximum load current of 150mA at 125Vac/dc and Ron < 6.5Ω. Alarm Interface Connections Alarm Interface Connector Pin No. Alarm IN Alarm OUT 1 2 3 4 GND ALARM IN + 5 ALARM OUT - 6 ALARM OUT + 7 8 Page 7 of 12

Auxiliary 20mA Current Loop Data Channel Configuration The AMG5614A3 receive unit sends and receives 20mA data to/from an AMG5613A3 or rackmount equivalent AMG5613A3R transmit unit. The auxiliary data channel is provided by an X04058 daughter board which provides one bi-directional 20ma current loop data channel over 4-wires. The current loop will detect a 20mA current signal input through the IN+, I- terminals. It requires an active signal source, and will generate a matching 20mA signal at the other end of the link. The input IN+/IN- is isolated from GND, the output OUT- is connected to GND. The maximum bit rate available is 2400bps. The X04058 20mA current loop daughter board is pre-configured during manufacture to operate in Active Transmit / Passive Receive mode. There are no user adjustable features on this device. Data Interface Connections Connecter Pin No 1 20mA current loop 2 OUT - 3 GND 4 IN + 5 IN - OUT + Page 8 of 12

Physical Information Dimensions Height... 112mm Width... 170mm (excluding connectors) Depth... 35mm Weight... 600grams Mounting Details The AMG unit is supplied with a clip-on mounting bracket which should be attached to a panel or wall using 2 off 4.0mm screws, see diagram on page 1 for dimensions. The unit is clipped into the mounting bracket, and is then held firmly in position. Safety AMG Optical Fibre Products use Class 1 laser systems in accordance with EN 60825-2:2000. It is always advisable to follow good practice when working with optical fibre systems. This includes: Do not stare with unprotected eyes or with any unapproved collimating device at fibre ends or connector faces, or point them at other people. Use only approved filtered or attenuating viewing aids For other safety issues and advice on good practice associated with optical fibre systems, please see EN 60825-2:2000 or your local safety officer. Maintenance and Repair There are no user serviceable parts within AMG products. See unit data sheet for full specification. In case of problem or failure, please call your local support centre or contact: AMG Systems Ltd. at 3 The Omega Centre, Stratton Business Park, Biggleswade, Beds., SG18 8QB, UK. Phone Technical Support Email +44 (0) 1767 600 777 +44 (0) 1767 604 491 techsupport@amgsystems.com Page 9 of 12

This page is intentionally blank. Page 10 of 12

This page is intentionally blank. Page 11 of 12

This page is intentionally blank. Page 12 of 12