Explosion-Proof Forced Air Unit Heater - XGB

Similar documents
Explosion-Proof Forced Air Unit Heater - XGB

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

Electric Explosion-Proof Heaters & Thermostats. Product Catalog

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

Electric Explosion-Proof Heaters & Thermostats. Product Catalog

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

FX5 Series Explosion-Proof Electric Air Heaters

CR1 Series Triton Corrosion Resistant Washdown Heaters

Edmonton Head Office & Factory 5918 Roper Road, Edmonton, Alberta, Canada T6B 3E1 P F Toll Free

Ultra-Safe EXP Unit Heater

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S

Industrial Air Heaters

Thermal Devices, Inc. Mount Airy, Maryland USA

FE1 Explosion-Proof Electric Air Heaters

Description. Construction

KUH. Horizontal Unit Heater. Applications. Description

Description. Applications

Description. Applications

CX1 ProVector Explosion-Proof Heaters

CF1 ProVector Explosion-Proof Heaters

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

LUH HORIZONTAL FAN-FORCED UNIT HEATER

Product Catalog. Air and Space Heaters. Section C

Comfort. Description. Applications

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Brasch Hazardous Location Unit Heaters

SUBMITTAL SCHEDULE & DATA

HUH2. Hydronic Unit Heater CRN: 0H C 400 psig (2758 KPa) Industrial Grade Heat-Exchanger Unit Heaters

XEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Explosion Proof Hazardous Location Roof Top A/C Units

ULTRA-SAFE Explosion-proof Duct Heaters

Explosion-Proof and Fan-Forced Unit Heaters. Our products do more in a wide range of applications. Expect More.

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Wall, Ceiling and Floor Heaters. Commercial & Industrial Electric heating and controls

EXH Series Explosionproof Electric Air Heaters

HD3D Forced-Air Heater

Type UB-2502A and UB-3002A Forced-Air Heater

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts.

ULTRA-SAFE Explosion-proof Duct Heaters

Applications. Standard Materials

( )

(770) wwww.southgateprocess.com

GREEN REFRIGERANT R-410A

Capacity: 1.5 to 6.0 Ton

RTXP2 Series - Division 1 OR 2 / Zone 0, 1,OR 2

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

RED DOT UNITS HEATER ONLY. Heaters PAGE 51

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

CXH-A Forced-Air Heater

WALL-MOUNT HEAT PUMPS - (60HZ)

HLA Series Hazardous Location Fan Forced Unit Heater

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

3000 Series Fan Forced Ceiling Heater Series Commercial Fan Forced Ceiling Heater

Split System Heat Pumps

HLA Series Hazardous Location Fan Forced Unit Heater

Capacity: 1.5 to 6.0 Ton

VACPB1 Series - 60 Hz Models

INSTALLATIONN GUIDE & OPERATION MANUAL

Commercial High-Efficiency Condensing Units

Owner s Manual. FX4 Series. Electric Forced Air Heaters for Hazardous Locations

Electric Unit Heaters

40E ELECTRIC FAN HEATER

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Refer to page 9 for information regarding the Breeze TM AccuSpec Sizing and Selection Program

Electric Unit Heaters for Standard and Hazardous (Classified) Locations

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Wall Mounted Air Conditioners with Gas Heat Models AVGA

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

General Description. Operation

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Concealed Ducted Split Series R-407C MBH

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

40E ELECTRIC FAN HEATER

Electric Space Heater

D Built-in door interlocking disconnect switch E Monel elements 1st Generation. Heater Kilowatts kw kw kw kw kw

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Advance Release September 2009

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

CR1 Triton Series. Owner's Manual. Model Coding IMPORTANT INSTRUCTIONS - SAVE THESE INSTRUCTIONS. Corrosion-Resistant Washdown Unit Heaters

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

TECHNICAL GUIDE DESCRIPTION EA090/FA090 SPLIT-SYSTEM HEAT PUMPS OUTDOOR UNIT INDOOR UNIT

Installation & Maintenance Instructions

LOW PROFILE UNIT COOLER

HI Industrial Utility Heater HI Soleus Air International

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

STEAM/HOT WATER UNIT HEATERS

RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

AIR-CONDITIONER SERVICE MANUAL

High Heat COP. High/Low Stage

Installation, Operation and

LOW PROFILE UNIT COOLER

Transcription:

Explosion-Proof Forced Air Unit Heater - XGB The XGB Series hazardous environment heater is designed to accommodate your requirements with flexibility and ease of maintenance, even under the toughest conditions. XGB unit heaters are available in two sizes, small cabinet units with ratings of up to 10 kw and large cabinet units with ratings of up to 35 kw. Applications The XGB is designed specifically for heating industrial spaces where potentially explosive substances are or may be present. Typical hazardous location environments include: Water and sewage treatment plants Oil refineries Compressor stations Pulp and paper mills Paint storage booths Cement plants Mines Marine and offshore Certification Certified by CSA to Canadian and US standards, with standard models approved for the following: Class I, Division 1 & 2, Groups C & D Class II, Division 1, Groups E, F & G Class II, Division 2, Groups F & G NOTE: Group B and 50 Hz constructions available on large cabinet construction only on special request. Class II and some atmospheric groups are not available in every kw rating. Model Coding Flow Adjustment In structures with high ceilings, other units may not have the range of motion needed to direct air flow to the floor. The XGB allows the unit to be tilted at a 30 angle below the horizontal. For lateral airflow, the entire louvre assembly can be rotated 90. No Conduit Seal Required A factory installed conduit seal provides the necessary isolation between the supply and control housings. In Division 2, Zone 2 applications, a field installed conduit seal may not be required. Simplified Wiring To facilitate installation, the explosion-proof unit heaters feature Thermon Heating Systems patented x-max housing with slide out terminal block trolley for connection of the electrical supply. XGB - 38 T3B 3-1 - T Model Series 038-3.75 kw 050-5 kw 075-7.5 kw 100-10 kw 150-15 kw Wattage 200-20 kw 225-22.5 kw 250-25 kw 300-30 kw 350-35 kw Temperature Code T3B - 329 F (165 C) T3A - 356 F (180 C) T2D - 215 C (419 F) T2C - 230 C (446 F) Heater Voltage 2 - V 3-240V 7 - V 8-600V *This nomenclature illustration is intended primarily to explain how a product part number is defi ned. Not all wattage, size and temperature code combinations are available. Please consult Table 3 or Table 4, page 8 for availability. Phase 1-1 Phase 3-3 Phase Options T - Thermostat R - Moisture-Resistant Design EW - 50 Hz Construction H - Div. 2, Group B, C, D M - Special Mechanical Features E - Special Electrical Feature - Built-in Disconnect 7

Table 3 Norseman TM XGB Unit Heaters - Small Cabinet Units XGB038T3B XGB050T3B XGB075T3A XGB100T2C kw Btu/hr 3.75 (12795) 5 (17060) 7.5 (25590) 10 (34120) V CFM (L/s) Temp Rise Temperature Code Class I Class II Maximum Line Amps Recommended Fuse Size (Amps) F C T2C T2D T3A T3B C D E F G 1Ø 3Ø 1Ø 3Ø 240 17 10 25 15 13 7.4 6 10 600 850 5 10 (400) 19 11 25 15 25 15 35 20 240 22 13 30 20 18 9.8 7 10 600 6 10 37 22 50 30 240 32 19 40 25 23 12.5 10 15 600 1000 8 10 (470) 29 40 240 43 25 60 35 30 16.7 13 20 600 11 15 Table 4 Norseman TM XGB Unit Heaters - Large Cabinet Units kw Btu/hr V CFM (L/s) Temp Rise Temperature Code Class I Class II Maximum Line Amps Recommended Fuse Size (Amps) F C T2C T2D T3A T3B C D E F G 1Ø 3Ø 1Ø 3Ø 30 40 XGB100T3B 10 (34120) 240 47 26 60 35 16 9.0 13 20 600 11 15 44 60 XGB150T3B 15 (51180) 240 38 50 24 13.5 19 25 600 15 20 Explosion-Proof Forced Air Unit Heater XGB XGB200T3B XGB225T3B XGB250T3A XGB300T2D XGB350T2C 20 (68250) 22.5 (76770) 25 (85300) 30 (102360) 35 (119420) 1850 25 35 (870) 32 17.8 600 20 25 28 35 36 20.0 600 23 30 31 40 41 22.8 600 25 35 37 50 49 27.2 600 30 40 43 60 57 31.5 600 34 45 8

Standard Features Small Cabinet 1/12 HP explosion-proof motor Inlet wire guard Extra heavy wall tubular steel finned heating elements with nickel plated finish Patented x-max explosion-proof terminal housing 120V control circuit includes: Derated magnetic contactor Dual automatic reset high limits Transformer Heavy duty 16-gauge stainless steel casing Outlet louvre assembly Swivel bracket Factory installed conduit seal Supply connection housing Terminal block for supply wiring and thermostat connection Large Cabinet 1/2 HP explosion-proof motor Inlet guard Extra heavy wall tubular steel finned heating elements with nickel plated finish Patented x-max explosion-proof terminal housing 120V control circuit includes: Derated magnetic contactor Dual automatic reset high limits Transformer Fan delay relay Control fuse Heavy duty 16-gauge stainless steel casing Outlet louvre assembly Swivel bracket Factory installed conduit seal Supply connection housing Terminal block for supply wiring and thermostat connection Optional Features Built-in, externally adjustable thermostat Built-in disconnect switch Moisture-resistant construction AUTO/OFF/FAN ONLY switch Pilot light Manual reset high limit Arctic duty design Class I, Division 2, Groups B, C & D design available on request* Group E* 50 Hz construction* *Large cabinet only. Mounting Accessories Ceiling mount kit; Wall mount kit; Post mount kit; Floor stand kit. Thermostats Thermon Heating Systems offers a wide variety of explosion-proof thermostats to suit most every need. unit heaters are available with optional built-in, externally adjustable, bulb-type thermostats. Thermostats for remote mounting can be provided upon request. Motors Fractional horsepower, 1725 RPM explosion-proof motor with double shielded ball bearings and built-in thermal overload. Small cabinet units use 1/12 HP motor approved for Class I, Group D; Class II, Groups F and G. Large cabinet units use 1/2 HP motor approved for Class I, Groups C and D; Class II, Groups E, F and G, as standard. NOTE: Not all options are available on all models or kw ratings. Check factory for options and construction availability prior to ordering. Outlet Louvres A louvred grille on the heater outlet end is supplied as standard. The louver assembly may be positioned either horizontally or vertically for maximum flexibility. NOTE: Proper motor/fan rotation, viewed from the rear of the heater, is counter-clockwise for small cabinet heaters and clockwise for the large cabinet units, as indicated by the fan rotation label on the heater. Incorrect rotation of the fan will cause the heater to overheat and cycle on the high limits. Consult factory in case of incorrect rotation. 9

Heater Dimensions and Weight Table 5 Heater Dimensions Small Cabinet Large Cabinet in (mm) A B C D1 D2 16.875 8.875 25.1875 17.5 (429) (225) (640) (445) 20.125 8.875 29.25 31.25 (511) (225) (743) (794) Table 6 Heater Weight kw Rating Heater Weight lbs (kg) Shipping Weight lbs (kg) Small Cabinet 3.75 to 10 100 (45) 110 (50) Large Cabinet 10 to 15 154 (66) 182 (83) 20 to 35 185 (84) 222 (101) Figure 1 XGB Dimensions Temperature Control Built-In Thermostat (Optional) When specified, the unit comes equipped with a built-in thermostat prewired to all other standard controls. Set the temperature to the desired operating condition. Remote Thermostat (Optional) Install the XT thermostat in accordance with the instruction sheet provided. Terminals T1 and T2 in the heater supply housing are provided for connection to a remote thermostat and are prewired to the rest of the control circuit. Remove the jumper wire between T1 and T2 and connect the thermostat to these terminals. Set the temperature to the desired operating condition. AUTO/OFF/FAN-ONLY SWITCH (Optional) Explosion-Proof Forced Air Unit Heater XGB If ordered, a factory installed AUTO/OFF/FAN-ONLY switch may be included on the heater. The fan-only feature allows the heater to cycle in a heat mode dictated by the controlling thermostat, even though the fan is operating continuously. Manual Reset High-Limit (Optional) If it is required, the heater can be equipped with one manual reset high-limit. This manual reset high-limit is installed in lieu of one of the auto-reset high-limits. Normal operation of the heater remains the same unless the manual reset high-limit trips, in which case the limit must be reset manually. 10

Mounting Figure 2 Ceiling Mounting Figure 4 Post Mounting Figure 3 Wall Mounting Table 7 Mounting Kit Part Numbers Description AC-CM-01 Ceiling Mount Kit AC-WM-01 Wall Mount Kit AC-PM-01 Post Mount Kit AC-FMS-01 Floor Stand Kit Figure 5 Floor Stand Mounting 11