McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

Similar documents
McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

McQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016

McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978

Climate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

Product Data. Single-Package Horizontally Mounted Water Source Heat Pumps with Electronic

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018

Catalog McQuay Enfinity Horizontal & Vertical Water Source Heat Pumps

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008

McQuay Enfinity TM. Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton. Catalog

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

McQuay Horizontal Water Source Heat Pump 1/2 to 6 Ton

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

MARVAIR CLASSIC HEAT PUMPS MODELS AVP HP EXPLODED VIEW PARTS ID

CMA Dishmachines Knott Avenue Garden Grove, CA Undercounter High Temperature Dishwasher. Service Replacement Parts.

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

GUIDE SPECIFICATIONS AQUARIUS ii

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012

PARTS LIST GEOTHERMAL HEAT PUMPS HRH/HRV & HOT WATER GENERATOR HWG

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com

REPLACEMENT PARTS MANUAL

GUIDE SPECIFICATIONS AQUARIUS ii

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Enfinity Console Water Source Heat Pumps 1/2 to 1½ Ton

Product Data. Features/Benefits. AQUAZONE 50PCH,PCV Compact Water Source Heat Pumps with PURON Refrigerant (R-410A) 50 Hz

Genesis Compact (GC) Series Submittal Data

Parts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

Console Water Source Heat Pumps

Air Cooled Scroll Compressor Condensing Unit

McQuay Enfinity (R-410A) and Standard (R-22) Horizontal Water Source Heat Pumps

Effective october 14, 2014

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0806, ICE1006 Includes 50Hz. and 3 Phase Units

CME1856W Service Parts

Catalog SmartSource Two-Stage Horizontal & Vertical Water Source Heat Pumps

AVAILABLE WITH ENERGY SAVING ECM MOTOR

DXM CONTROLS. DXM Digital Heat Pump Controllers. Application, Operation, & Maintenance. Table of Contents

SECTION WATER-SOURCE UNITARY HEAT PUMPS

REPLACEMENT PARTS MANUAL

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Replacement Parts List For Models COS-20G

ECOJET EJ-10E & EJ-7E ELECTRIC CONVECTION STEAMER W/TWIN GENERATORS PARTS AND SERVICE MANUAL

UNIVERSAL 750 PRE-MIX DISPENSER

MP GS/GD 10 GAS. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

Humidifiers Dealer Parts List Model 400/400M Humidifiers

DXM2 Digital Heat Pump Controller

Vertical Water Source Heat Pump & Cooling Only Units

UNIT DIGITAL CONTROLS APPLICATION, OPERATION & MAINTENANCE

FCC Fan-Coil Units High-Performance, Vertical

ENGINEERING SPECIFICATIONS

Vertical V*B Series Fan Coil Technical Catalog

ENGINEERING SPECIFICATIONS

CME1856W Service Parts

CMS1402 SERVICE PARTS

SECTION CONVECTION HEATING AND COOLING UNITS

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606

CXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers.

PS-3E AND PS-6E ELECTRIC CONVECTON STEAMERS PARTS AND SERVICE MANUAL

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

Parts List. Modular Crescent Cuber. Models KM-340MAJ, MWJ. hoshizakiamerica.com

Humidifiers Dealer Parts List

RP8.1Y (ERRATA 1) (202) 2 of 8

SERVICE PARTS MANUAL ICE SERIES CUBERS MODEL-ICE0250, ICE0400, ICE0500, ICE0606 Includes 50Hz. Units

water to water heat pumps

SECTION WATER-SOURCE UNITARY HEAT PUMPS

REPLACEMENT PARTS MANUAL

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016

PARTS MANUAL. American Dish Service ADS CONVEYOR DISHWASHER MODELS: ADC-44 L-R/R-L EFFECTIVE: SEPTEMBER 1, 2001

Catalog Enfinity Large Horizontal Water Source Heat Pumps with R-410A Refrigerant

Enfinity Horizontal Ceiling Catalog Water Source Heat Pumps

Concealed Ducted Split Series R-407C MBH

MARVAIR COMPAC AIR CONDITIONERS MODELS AVP EXPLODED VIEW PARTS ID

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

ICEU 36 SPARE PARTS LIST REV. 07/2016

Transcription:

Replacement Parts List No. 055237600 Revision D 08/2017 McQuay Vertical Water Source Heat Pump FCV, FCG, FCW 036, 042 Vintage A Last Manufactured: 1993 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

Contents Parts List Revision History... 3 Nomenclatures Serial Number... 4 Model Number... 4 Field Installed Accessories Thermostats and Subbases for Electromechanical Control Units... 5 Thermostats and Subbases for Mark IV Control Units... 5 Thermostat Accessories... 6 Hoses & Valves... 6 Filters and Filter Components... 6 Unit Accessories... 7 Refrigeration Circuit Diagram... 8 Components... 9, 10 Fan and Housing Assembly...11 Control Box Accessory & Standard Control Layout... 12 MicroTech Control Layout... 13 Components... 14, 15 Critical Parts List... CPL1 WSHP; FCV,FCG,FCW 036, 042 Vintage A Rev. D 08/17 RPL 0552376 / Page 2

Parts List Revision History Revision Date A 06/99 Page 3-Added Revision History page. Page 4-Correct part numbers for Programmable Microelectronic Thermostats on Electromechanical Control units. B 07/06 Page 12- Bub#18 Changed blower housing pn 60669605 to 60699605. C 01/13 Reformat to current standards. Change PM6.5 to CS6. Change p/ns to 9 Digits. Page 4- Added Serial Number (2/1999 to present). CPL1- Add Critical Parts List. D 08/17 Rebrand Daikin. Delete sheet metal. Pages 11-12 Combine onto one page Fan and Housing Assembly. Pages 17-19 Delete Panels and Cabinet Assembly. CPL1- Rebrand and delete Refrigeration Circuit. Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330 WSHP; FCV,FCG,FCW 036, 042 Vintage A Rev. D 08/17 RPL 0552376 / Page 3

Nomenclatures Serial Number 7 U A 00000 00 Plant Identification Number 7 = Auburn Year Manufactured S = 1987 T = 1988 U = 1989 V= 1990 W= 1991 X= 1992 Y= 1993 Engineering Revision Serial Number Month Manufactured A=January G= July B=February I=August C=March J=September D= April K=October E= May L=November F= June M=December Digits 1-3 Model Type FCV = Floor Concealed Vertical Water Source Heat Pump FCG = Floor Concealed Vertical Cooling Only FCW = Floor Concealed Vertical Extended Range Heat Pump Digits 4-7 Unit Size / Vintage 036A = 36,500 Nominal Cooling Btuh 042A = 41,000 Nominal Cooling Btuh Model Number FCG 036A E G L Digit 10 Return Air Arrangement L = Left Hand Return R = Right Hand Return Digit 9 Voltage G = 208- N = 265/60/1 F = 208- T = Q = Digit 8 Control System E = Electromechanical Control M = Mark IV Control C = MicroTech Control WSHP; FCV,FCG,FCW 036, 042 Vintage A Rev. D 08/17 RPL 0552376 / Page 4

Field Installed Accessories Thermostats & Subbases for Electromechanical Control Unit Part Number STANDARD MANUAL CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T834C with 803005245 no LED. Mounts vertically. System "Heat-Off-Cool" switch and fan. "On-Auto" switch. (Includes subbase) STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE. Thermostat 060687201 Honeywell T874/Q674. LED for "Service." Mounts horizontal. System "Off-Auto" switch and fan "On-Auto" switch. Subbase 060687401 DELUXE AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE WITH NIGHT SETBACK. Honeywell T874/Q674. LED for "Service." Mounts horizontal. Requires factory installed night setback relay or field installed night setback or night setback/demand control relay. Night setback bulb set 8 o F below day heating setpoint. System "Off-Auto" switch and fan "On-Auto" switch. Requires minimum of 6 wires. PROGRAMMABLE MICROELECTRONIC THERMOSTAT. Auto or manual changeover. Mounts horizontal. System "Off-Auto" switch, temp. "Heat-Auto-Cool" switch and fan "On-Auto" switch. PROGRAMMABLE MICROELECTRONIC THERMOSTAT WITH REMOTE SENSOR. Auto or manual changeover. Mounts horizontal. System "Off-Auto" switch, temp. "Heat-Auto-Cool" switch and fan "On-Auto" switch. Honeywell T862. *Replaces 060602301 (Digistat HP-2000DC) and 061212901(Digistat HP-1000 DC) Thermostat. Thermostat 060687301 Subbase 060687401 067114301* (Includes subbase) 067114301 (Includes subbase) Thermostats & Subbases for Mark IV Control Unit 803005245 (Includes subbase) Thermostat 060685301 060684801 060685301 060684901 061202402 ** 061202601 066816602 STANDARD MANUAL CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T834C with no LED. Mounts vertically. System "Heat-Off-Cool" switch and fan. "On-Auto" switch. STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T874/Q674. LED for "Service." Mounts horizontal. System "Off-Auto" switch and fan "On-Auto" switch. Subbase STANDARD MANUAL & AUTO CHANGEOVER THERMOSTAT & Thermostat SUBBASE. Honeywell T874/Q674. LED for "Service." Mounts horizontal. System "Off-Heat-Auto-Cool" switch and fan "On-Auto" switch. Subbase DELUXE AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE WITH NIGHT SETBACK AND OVERRIDE. Honeywell T874/Q674. LED Thermostat for "Service." Mounts horizontal. Requires grounding of unit "U" terminal. Night setback bulb set 12 o F below day heat setpoint. System "Off-Auto" Subbase switch and fan "On-Auto-Override" switch. STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE Thermostat FOR OPERATING TWO UNITS. Honeywell T874/Q674. LED for "Ser- Subbase vice." Mounts horizontal. System "Off-Auto" switch. 060684701 PROGRAMMABLE MICROELECTRONIC THERMOSTAT. Auto or manual changeover. Mounts horizontal. System "Off-Auto" switch, temp. "Heat-Auto-Cool" switch and fan "On-Auto" switch. PROGRAMMABLE MICROELECTRONIC THERMOSTAT WITH REMOTE SENSOR. "Heat-Auto-Cool" switch and fan "On-Auto" switch. Honeywell T862. * Replaces 060602301 (Digistat HP-2000DC) and 061212901 (Digistat HP-1000 DC) Thermostat. Part Number 067114201 * (Includes subbase) 067114201 (Includes subbase) ** Deluxe Thermostat was 060685501 (T874D1686) which has been phased out. When replacing 060685501 with 061202402, must also replace the Subbase from 060684801 to 061202601. Thermostat 061202402 is not compatible with 060684801 (Q674C-1298) Subbase. WSHP; FCV,FCG,FCW 036, 042 Vintage A Rev. D 08/17 RPL 0552376 / Page 5

Field Installed Accessories Thermostat Accessories NIGHT SETBACK THERMOSTAT. Honeywell T822. Mounts vertically. No LED. No switches. For applications requiring a separate NSB stat. UNIVERSAL THERMOSTAT GUARD. Honeywell TG500A. Clear plastic with ring base, lock and keys. DELUXE LOCKING COVER FOR T874/Q674 THERMOSTATS. Honeywell TG504A. Applies only to T874/Q674 thermostats. Replaces standard thermostat cover. Includes cover, lock and keys. ADAPTER PLATE FOR T874/Q674 THERMOSTATS. Allows for horizontal thermostat to be mounted on a vertical junction box 7-DAY TIME CLOCK. OVERRIDE TIMER - 1 HOUR. OVERRIDE TIMER - 6 HOUR. Part Number 803005180 802005426 060684501 802007673 4ETA7276 802005717 802005718 Hoses & Valves Part Number STANDARD SUPPLY OR RETURN HOSE. Rubber hose with MPT 2' long, 3/4" I.D. 061268803 swivel hydraulic fittings on each end. Order two per unit. 3' long, 3/4" I.D. 061268804 FIRE RATED SUPPLY OR RETURN HOSE. Stainless steel, braided 2' long, 3/4" I.D. 061269003 hose with one MPT and one MPT swivel fitting. Order 2 per unit. 3' long. 3/4" I.D. 061269004 CONDENSATE HOSE ASSEMBLY. Requires trap by others. Order Clear plastic, 38" long 060687701 one per unit. Fire rated, 24" long 061300001 Includes fitting to be soldered on unit. Fire rated, 36" long 061300002 BALL VALVE. Combination shutoff and balancing valve with memory 3/4" FPT 802026098 stop. Order two per unit. Filters & Filter Components Part Number 2" THICK THROWAWAY FILTER. Fits into 2" thick filter rack. Must order in multiples of 12. 060687109 1" THICK THROWAWAY FILTER. Replacement for standard filter. Must order in multiples of 12. 060604808 1" THICK CLEANABLE FILTER. Must order in multiples of 12. 060687009 2" THICK PLEATED FILTER, 35% EFFICIENT. Must order in multiples of 12. 060759809 RETURN AIR DUCT COLLAR & TWO INCH FILTER RACK. 060917404 WSHP; FCV,FCG,FCW 036, 042 Vintage A Rev. D 08/17 RPL 0552376 / Page 6

Field Installed Accessories Unit Accessories SHUTDOWN RELAY KIT FOR ELECTROMECHANICAL CONTROL UNITS. For shutdown of the unit from an external 24 volt AC power source. Relay mounts at control box. NIGHT SETBACK RELAY KIT FOR ELECTROMECHANICAL UNITS. Relay to put unit into NSB mode from an external 24 volt AC power source. Relay mounts at control box. Operation requires ACO stat with built-in NSB or a separate NSB stat. NIGHT SETBACK/DEMAND CONTROL RELAY KIT - ELECTROMECHANICAL UNITS. Relay to put unit into NSB mode from one 24 volt AC power source and to put unit into load shed mode from another 24 volt AC power source (3 total wires required). Relay mounts at control box, operation requires ACO stat with built-in NSB or separate NSB stat. RANDOM START RELAY - ELECTROMECHANICAL CONTROL. 115, 208/230, 265V UNITS. Time delay relay to delay compressor startup when coming off night operation and to not allow all units to start at the same time. 460, 575V AUXILIARY RELAY. 24 volt DC relay to be wired to low voltage terminal block to allow a set of SPDT pilot duty contacts to operate miscellaneous devices when the fan or compressor operate. BOILERLESS SYSTEM KIT. Must be Mark IV control unit. Includes electronics and sensor to lock out compressor operation at 50 o F to 60 o F EWT and provide SPNO contacts to a field supplied electric heater control system. LOGIC LINK II. Must be Mark IV control unit. Includes electronics, ACO stat and subbase for adjustable night setback and setup and compressor only shutdown (demand control/load shed) from a 24 volt AC external power source. Also includes 1 hour override control at the thermostat. LOGIC LINK II WITH BOILERLESS SYSTEM. Incorporates both Logic Link and Boilerless System control in one package. Includes ACO stat and subbase, and EWT sensor. Requires 24 volt AC external power source. MULTIPLE UNIT CONTROL PANEL. Allows master unit to be Master & 1 Slave controlled by any thermostat. Slave units "follow" with paralleled Master & 3 Slaves Kit operation. Not recommended with Boilerless System. MOTORIZED VALVE. Includes prewired valve/operator, 3 foot conduit assembly with leads and quick connects. Valve shuts water 3/4" FPT flow off for variable pumping. 300 psig maximum operating pressure. Requires control relay. See below. CONTROL RELAY FOR MOTORIZED VALVE. Part Number 061019403 802005728 802007881 802005496 802005498 803005073 060844701 060845001 (NLA) 060846001 (NLA) 803005159 056794201 060977301 059004354 INTERFACE KIT. For other electronic or DDC controliers. Heat, Cool & Fan Ctrl 061047701 Heat, Cool & Fan Ctrl & Fault Relay 061047801 NLA = Part Numbers 060845001 & 060846001 are no longer available as a kit. Individual parts may be available. WSHP; FCV,FCG,FCW 036, 042 Vintage A Rev. D 08/17 RPL 0552376 / Page 7

Refrigeration Circuit Diagram TO WATER REGULATING VALVE (OPTION) 2 6 7 5 4 8 3 10 11 12 1 WSHP; FCV,FCG,FCW 036, 042 Vintage A Rev. D 08/17 RPL 0552376 / Page 8

Refrigeration Circuit Components 036 042 Bub. Num. Part Number 265/60/1 1 Compressor 2 060603501 1 1 1 Compressor 3 060743701 1 1 1 Compressor 2 060603502 1 1 Compressor 3 060743702 1 1 Compressor 2 060603504 1 1 1 Compressor 3 060743704 1 1 1 Compressor 2 060603503 1 1 Compressor 3 060743703 1 1 Compressor 060603602 1 1 Compressor 2 060603601 1 1 1 Compressor 3 060743801 1 1 1 Compressor 2 060603603 1 1 1 Compressor 3 060743803 1 1 1 Compressor 2 060603602* 1 1 Compressor 3 060743802 1 1 Compressor 060603101 1 N/S Plug, Threaded 1/2"-13 802028117 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Capacitor, Compr. 40 Mfd, 370V 802007850 1 1 N/S Capacitor, Compr. 35 Mfd, 440V 802007857 1 1 1 N/S Bracket, Capacitor 050010570 1 1 1 1 1 2 Coaxial Coil* Copper 060602101 1 1 1 1 1 1 1 2 Coaxial Coil* Cupronickel 060602102 1 1 1 1 1 1 1 2 Coaxial Coil* Copper 060602201 1 1 1 1 1 1 2 Coaxial Coil* Cupronickel 060602202 1 1 1 1 1 1 3 Fin Tubular Coil** 056915801 1 1 1 1 1 1 1 3 Fin Tubular Coil** 056911801 1 1 1 1 1 1 4 Capillary 33 X.059 X.112 802001041 5 5 5 5 5 5 5 4 Capillary 25 X.054 X.106 060634703 6 6 6 6 6 6 5 Strainer / Distributor 060623704 1 1 1 1 1 1 1 5 Strainer / Distributor 060676205 1 1 1 1 1 1 N/S = Not shown on diagram 2 FCV, FCG only. 3 FCW only. * = Water to Refrigerant ** = Air to Refrigerant Continued on next page. WSHP; FCV,FCG,FCW 036, 042 Vintage A Rev. D 08/17 RPL 0552376 / Page 9

Refrigeration Circuit Components 036 042 Bub. Num. Part Number 265/60/1 6 Reversing Valve 043755500 1 1 1 1 1 1 1 1 1 1 1 1 1 7 Solenoid, Reversing Valve 1 24V 802026121 1 1 1 1 1 1 1 1 1 1 1 1 1 8 Switch, High Pressure 802005813 1 1 1 1 1 1 1 1 1 1 1 1 1 10 Thermostat, Low Temp. Cutout 2 802005724 1 1 1 1 1 1 1 1 1 1 1 1 1 12 Accumulator 3 060722401 1 1 1 1 1 1 1 12 Accumulator 3 802025545 1 1 1 1 1 1 N/S Flanged Nut, Compressor Mounting 802012035 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Grommet, Compressor Mounting 6 802003084 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Sleeve, Compressor Grommet 6 802003078 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Sleeve, Compressor Grommet 7 802003425 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Spacer, Lower, Compressor Mtg. 7 060687901 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Spacer, Top, Compressor Mtg. 7 060687801 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Spring, Compressor Mounting 7 060688001 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Water Regulating Valve 2,15 802026198 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Water Regulating Valve 3,15 802026201 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Drain Pan 060852402 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S = Not shown on diagram 1 FCV, FCW only. 2 FCV, FCG only. 3 FCW, only. 6 Used only on Standard Construction units. 7 Used on all Extra Quiet Construction units. 15 Only used on units with Water Regulating Valve option. WSHP; FCV,FCG,FCW 036, 042 Vintage A Rev. D 08/17 RPL 0552376 / Page 10

Fan and Housing Assembly Cabinet/Chassis Components 16 21 19 18 17 20 15 036 042 Bub. Num. Part Number 265/60/1 15 Motor 1/2 HP 060704601 1 1 1 1 15 Motor 1/2 HP 060704602 1 15 Motor 1/2 HP 060704603 1 15 Motor 1/2 HP 060704604 1 15 Motor 1/3 HP 060961801 1 1 1 1 15 Motor 1/3 HP 060961803 1 15 Motor 1/3 HP 060961804 1 N/S Kit, Motor Mount 062200601 1 1 1 1 1 1 1 1 1 1 1 1 1 16 Run Capacitor, Motor (7.5 MFD, 440V) 802007526 1 1 1 1 1 1 1 16 Run Capacitor, Motor (7.5 MFD, 440V) 037516404 1 1 1 1 1 1 17 Bracket, Capacitor 050010570 1 1 1 1 1 1 1 1 1 1 1 1 1 18 Blower Housing Weldment 060699604 1 1 1 1 1 1 1 18 Blower Housing Weldment 060699605 1 1 1 1 1 1 19 Inlet Ring 060828801 1 1 1 1 1 1 1 19 Inlet Ring 060829001 1 1 1 1 1 1 20 Wheel Blower 802000037 1 1 1 1 1 1 1 20 Wheel Blower 061406601 1 1 1 1 1 1 21 Protector Terminal 802007316 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Cabinet/Chassis components 1 N/S = Not shown on diagram. 1 Contact Daikin with unit model and serial number for part numbers on Sheet Metal components. WSHP; FCV,FCG,FCW 036, 042 Vintage A Rev. D 08/17 RPL 0552376 / Page 11

Control Box Standard Control Layout 50HZ TERMINAL BLOCK & BRACKET WSHP; FCV,FCG,FCW 036, 042 Vintage A Rev. D 08/17 RPL 0552376 / Page 12

Control Box Layout - MicroTech Control MicroTech Control Layout 31 23 45 22 26 27 39 24 34 25 WSHP; FCV,FCG,FCW 036, 042 Vintage A Rev. D 08/17 RPL 0552376 / Page 13

Control Box Components 036 042 Bub. Num. Part Number 265/60/1 22 Barrier, Control Box 060816201 1 1 1 1 1 1 1 1 1 1 1 1 1 22 Barrier, Control Box * 060981901 1 1 1 1 1 1 1 1 1 1 1 23 Circuit Board, Mark-IV, DC 8 056792401K 1 1 1 1 1 1 1 1 1 1 1 1 1 23 Circuit Board, Electromechanical 9 60679202K 1 1 1 1 1 1 1 1 1 1 1 1 1 23 Circuit Board, Microtech* 060959401 1 1 1 1 1 1 1 1 1 1 1 N/S Sensor Assembly, Temperature * 060988402 1 1 1 1 1 1 1 1 1 1 1 24 Block, Terminal, 3-Pole * 049759001 2 2 2 2 2 2 2 2 2 2 2 25 Block, Terminal, 4-Pole * 049759002 1 1 1 1 1 1 1 1 1 1 1 26 Block, Terminal, 5-Pole * 049759003 1 1 1 1 1 1 1 1 1 1 1 27 Panel, Mounting, PC Board 060981601 1 1 1 1 1 1 1 1 1 1 1 1 1 27 Panel, Mounting, PC Board * 060981701 1 1 1 1 1 1 1 1 1 1 1 28 Stand-Off * 802028130 1 1 1 1 1 1 1 1 1 1 1 28 Stand-Off 8 802028130 5 5 5 5 5 5 5 5 5 5 5 5 5 28 Stand-Off 9 802028130 4 4 4 4 4 4 4 4 4 4 4 4 4 29 Nylon Nut * 802012415 1 1 1 1 1 1 1 1 1 1 1 29 Nylon Nut 8 802012415 5 5 5 5 5 5 5 5 5 5 5 5 5 29 Nylon Nut 9 802012415 4 4 4 4 4 4 4 4 4 4 4 4 4 30 Control Box 060981501 1 1 1 1 1 1 1 1 1 1 1 1 1 31 Screw, Tapping 033153700 2 2 2 2 2 2 2 2 2 2 2 2 2 N/S Washer, Cupped 030388700 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Condensate Overflow Wire *, 8 056794401 1 1 1 1 1 1 1 1 1 1 1 1 1 32 Contactor, Compressor 25A 803005105 1 1 1 1 32 Contactor, Compressor * 25A 803005223 1 1 1 1 1 32 Contactor, Compressor 20A 802005655 1 32 Contactor, Compressor 25A 027514201 1 1 1 1 32 Contactor, Compressor * 20A 073322501 1 1 1 1 1 1 32 Contactor, Compressor 30A 803005233 1 1 N/S = Not shown on diagram * MicroTech Control units only. (Units with Model No. Digit 8 = C). 8 Mark IV Control units only. (Units with Model No. Digit 8 = M). 9 Electromechanical Control units only. (Units with Model No. Digit 8 = E). Continued on next page. WSHP; FCV,FCG,FCW 036, 042 Vintage A Rev. D 08/17 RPL 0552376 / Page 14

Control Box Components 036 042 Bub. Num. Part Number 265/60/1 33 Relay, Fan * 24VAC 047356506 1 1 1 1 1 1 1 1 1 33 Relay, Fan 24V SPDT 802005819 1 1 33 Relay, Fan 24V 802005906 1 1 34 Bracket, Control Option Mtg. 060830301 1 1 1 1 1 1 1 1 1 34 Bracket, Control Option Mtg. 061049101 1 1 1 1 35 Relay, Random Start 9,10 802005496 1 1 1 1 1 1 1 1 1 1 1 35 Relay, Random Start 9,10 802005498 1 1 36 Relay, Shutdown 9,11 24V 061019403 1 1 1 1 1 1 1 1 1 1 1 1 1 37 Relay, Night Setback 9,12 RK-7 802005728 1 1 1 1 1 1 1 1 1 1 1 1 1 37 Relay, Demand Control, Bd Galt 9,13 802007881 1 1 1 1 1 1 1 1 1 1 1 1 1 38 Relay, Auxiliary 14 24V BD 803005073 1 1 1 1 1 1 1 1 1 1 1 1 1 39 Relay, Timed Output * 24V 802005206 1 1 1 1 1 1 1 1 1 1 1 39 Relay, Boilerless System * 24V 802005206 1 1 1 1 1 1 1 1 1 1 1 39 Relay, Fresh Air Damper * 24V 802005206 1 1 1 1 1 1 1 1 1 1 1 39 Relay, Motorized Valve * 24V 802005206 1 1 1 1 1 1 1 1 1 1 1 N/S Suppressor / Diode Ass'y. * 061073401 1 1 1 1 1 1 1 1 1 1 1 40 Mount, Terminal Block 061131001 1 1 41 Terminal Block 802007432 4 4 42 End, Terminal Block 802007431 1 1 43 Terminal Lug 802007744 1 1 44 Transformer 208/230V - 24V 060614101 1 1 1 1 1 1 1 1 1 1 44 Transformer 277V, 24V 060630701 1 44 Transformer 480V, 24V 060676001 1 1 45 Transformer * 24V 060949301 1 1 1 1 1 1 1 1 1 1 1 N/S Condensate Overflow Switch 9 803005260 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Condensate Overflow Wire *, 8 056794401 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S = Not shown on diagram * MicroTech Control units only. (Units with Model No. Digit 8 = C). 8 Mark IV Control units only. (Units with Model No. Digit 8 = M). 9 Electromechanical Control units only. (Units with Model No. Digit 8 = E). 10 Only on units with Random Start Relay Option. 11 Only on units with Shutdown Relay Option. 12 Only on units with Night Setback Option. 13 Only on units with Demand Control Relay Option. 14 Only on units with Auxiliary Relay Option and without MicroTech Controller. WSHP; FCV,FCG,FCW 036, 042 Vintage A Rev. D 08/17 RPL 0552376 / Page 15

Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! McQuay Vertical WSHP FCV, FCG, FCW 036, 042 Vintage A Critical Components Unit Sizes Voltage Part Number Control Control Board, Electromechanical ALL ALL 60679202K Control Board, Mark-IV, DC ALL ALL 056792401K Control Board, MicroTech ALL ALL 060959401 Compressor Compressor 036 208/ 060603501 Compressor 036 208/ 060603504 Compressor 036 265/60/1 060603502 Compressor 036 060603503 Compressor 036 060603602 Compressor 042 208/ 060603601 Compressor 042 208/ 060603603 Compressor 042 060603602 Compressor 042 060603101 Compressor (FCW only) 036 208/ 060743701 Compressor (FCW only) 036 208/ 060743704 Compressor (FCW only) 036 265/60/1 060743702 Compressor (FCW only) 036 060743703 Compressor (FCW only) 036 060603602 Compressor (FCW only) 042 208/ 060743801 Compressor (FCW only) 042 208/ 060743803 Compressor (FCW only) 042 060743802 Compressor (FCW only) 042 060603101 Blower Motor Motor, 1/2HP 036 208//3 060704601 Motor, 1/2HP 036 265/60/1 060704602 Motor, 1/2HP 036 060704603 Motor, 1/2HP 036 060704604 Motor, 1/3HP 042 208//3 060961801 Motor, 1/3HP 042 060961803 Motor, 1/3HP 042 060961804 Fan Housing and Wheel Blower Housing 036 N/A 060699604 Blower Housing 042 N/A 060699605 Wheel, Blower 036 N/A 802000037 Wheel, Blower 042 N/A 061406601 Sensor Sensor, Temperature Assy ALL N/A 060988402 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call 1-800-37PARTS 552376 Rev. D 08/2017 CPL Page 1 of 1