CentaurPlus C27 Series 2 User Operating Instructions

Similar documents
CentaurPlus C21 Series 2 User Operating Instructions

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

User Operating Instructions Horstmann 425 Tiara/Diadem Electro-mechanical Programmers

425 Coronet Electro-mechanical Timeswitch User Operating Instructions

C-Stat 17-ZW User Instructions

ThermoPlus AS2-RF & ASR-RF Installation Instructions

CS027 User Instructions

MAKING MODERN LIVING POSSIBLE. FP975 7-Day Electronic Programmer. User Guide. Danfoss Heating

103E7. User Guide. 7-Day Electronic Timeswitch for Controlling Hot Water and Heating (Including Factory Replacement Units FRU) Danfoss Heating

CentaurPlus ZW and HRT4-ZW

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

ES3247B. 3 Channel Programmer. User and Installation Instructions

3 Channel Multi-Purpose Programmer User Instructions

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

ST9400A User Guide. Features

Installation and User Guide. Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU)

Electronic 7 Installation Instructions

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

RF Programmable Room Thermostat User Instructions

Drayton Digistat +3RF

103E5. Installation & User Instructions. Electronic timeswitch for controlling hot water and heating. including Factory Replacement Units (FRU)

Model: Touch-RF. 1 Wireless Series

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

Model: Slimline-B. Battery Series

AUTO CM CM USER GUIDE

Digital Room Thermostat

User Manual THR870CUK Programmable Thermostat

Operating Instructions Model : HC HC-N

Electrisaver User and Installation Instructions

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

Battery Powered Electronic Programmable Room Thermostat

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

Model: Slimline-RF. 1 Slimline Series

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

User Guide. Promax Store 24. Condensing Boiler with Integrated Hot Water Storage

102E7. Installation & User Instructions. 7-day electronic mini-programmer for controlling hot water and heating

Vokèra OpenTherm 711 without external sensor connected

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

Model: RT510RF. Installation Manual

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

INSTRUCTION MANUAL TRC-1490 Wireless Indoor and Outdoor Weather Station

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

irad Wireless Controller

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

User Manual THR872CUK Wireless Programmable Thermostat

Model: Available in : Sapphire Black and Glacier White. 1 Series

User Guide Y9420H Sundial RF 2 Pack 2

Microelectronic Programmable Thermostat Owner s Manual. 1 J.H Form Number

Operating Instructions Model: PRT/HW - PRT/HW-N Version 3. 09/09 Revision 2 Ref: PRT/HW/NV3

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

Operating Instructions

Owners Manual. HTC621W 7-Day Programmable Thermostat 3600W. HTC625W 7-Day Programmable Thermostat 4000W

Vokèra OpenTherm 711 with external sensor connected

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

Mynute. Standard efficiency system boiler 12e - 16e - 20e. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Model: Touch-RS. 1 Touch-RS

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Model : PRT-EN Model: PRT-EN1

GAS FIRED COOKERS. OPERATING INSTRUCTIONS MODEL: CAT - Enabled GUARANTEE INFORMATION FOR USE WHEN ORDERING SPARES: Cooker Model: Serial Number:

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

Model: Available in: Sapphire Black and Glacier White. 1 Series

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

Model: Slimline-N. 1 Slimline Series

Underfloor Heating Programmable Thermostat

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Owner s Manual. Model 8800 Universal Communicating Thermostat. Includes Operating Instructions and Warranty Information

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

425 series Electro-mechanical Programmers

Uponor Comfort-E Thermostat Dig. Prog Set T-86 INSTALLATION AND OPERATION MANUAL

Instruction Guide: Thermostat Operation

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

Owner s Manual. Part Number 33CS250-RC

SETTING UP GUIDE. This Handbook is for the Installer. You must read these instructions prior to installing and commissioning the Credanet system.

TWIN CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

ESRTP4RF. RF Programmable Room Thermostat with TPI, Optimum Stop, Delayed & Optimum Start. User and Installation Instructions

Installation and User Guide. Electro-mechanical mini programmer for controlling hot water and heating Including Factory Replacement Units (FRU)

OWNER S MANUAL. Part Number P RF

ST9000 FAMILY OF TIMERS & PROGRAMMERS FEATURES APPLICATIONS PRODUCT SPECIFICATION SHEET

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

TC-PHP01-A, TC-PAC01-A Comfort Series Programmable Thermostat. Owner s Manual

Installation and user manual

Programmable Interactive User Manual

ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

Model: PRT-TS / PRT-NTS

Owner s Manual. Digital. Heat Pump. 5+2 Day Programmable. Model S1-THEH21P5S HVAC SERVICE PARTS TM

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Model: Edge-HC. 1 edge-hc

Deaf & Hearing Impaired RadioLINK Alarm System

Transcription:

CentaurPlus C27 Series 2 User Operating Instructions Two Channel Central Heating and Hot Water r The Horstmann CentaurPlus C27 two channel programmer gives independent control over hot water and heating with up to 3 ON/ settings for each day of the week. It also has a 1 hour manual boost button for the hot water and an advance button for the central heating. There is also a programming switch allowing permanent selection of: /ON//. 1

The CentaurPlus C27 r The simple instructions contained in this user guide are designed to help with the programming and operation of the unit. 1 15 16 2 17 11 12 3 2 BOOST ADVANCE 13 9 14 10 4 5 6 7 8 1 SET indicator 2 Time of day 3 Switch period symbol 4 SET button 5 Hot water BOOST or adjust (-) button 6 Central Heating ADVANCE or adjust (+) button 7 Hot water (HW) or button 8 Central Heating (CH) or COPY button 9 Hot water ON indicator 10 Central heating ON indicator 11 SET positions 12 PROGRAMME positions 13 BOOST symbol 14 ADVANCE symbol 15 AM/ symbol 16 Day of week indicator 17 PROGRAMME indicators 2

Fully Pumped or Gravity System The installer will have set the programmer to suit the installed system. This is normally a Fully Pumped system which will allow independent control of the central heating and hot water, however on an old Gravity system the central heating and hot water are linked so that it is not possible to use the central heating independently. This will allow only one common time setting for both hot water and central heating, and will become apparent when setting the ON and times as both will be indicated together. Manual Overrides BOOST FUNCTION - 1 hour temporary override (HOT WATER ONLY) The boost facility will allow the user to boost the hot water channel which is currently for 1 hour. To indicate the boost being activated BOOST will be shown on the display for the duration of the boost period. The hot water channel ON indicator will also be illuminated. Press BOOST button once for 1 hour of hot water At any time during a BOOST period press BOOST again to return to normal programming RUN CLOCK HW PROG CH PROG BOOST HW CH Advance Function Brings forward the next on or off operation (CENTRAL HEATING ONLY) The advance facility will allow the user to switch the central heating channel ON which is currently or switch the central heating channel which is currently ON. To indicate the advance feature being activated ADVANCE will be shown on the display until the next programme switching time. The central heating ON indicator will also be illuminated. Press ADVANCE button once to move to the next ON/ time To cancel the advance press the ADVANCE button again. This will return the unit to its normal programme RUN CLOCK HW PROG CH PROG ADVANCE HW CH 3

Override Facilities With the CentaurPlus C27 programmer operating in the normal running mode it is possible to alter the functionality of the programme on each individual channel by means of the CH and HW. The options include; Auto - Channel follows all programmed ON and times. All day - Channel operates from 1st ON time until 3rd, ignoring all switching times in between. 24hrs - Channel will be constantly ON. Off - Channel will be constantly, there is the ability to turn off the heating during the summer without altering the programme times. On the hot water channel the boost is still available. As both channels are totally independent it is possible to have them set differently if necessary. All of the settings above will be permanent, i.e. unaffected by programme times, until alteration by the user. The diagram below illustrates how to alter the setting, it assumes that the channel is in the mode to begin with. Press HW OR CH once. goes from to Press HW OR CH again. goes from to Press HW OR CH again. goes from to Press HW OR CH again. goes from to will operate from 1st ON until 3rd period will be continuously ON will be continuously will return to normal ON and times HW CH HW CH HW CH HW CH 4

Setting Time of Day and Date The CentaurPlus C27 series 2 programmer has a built in clock and calendar. This will mean that you will need to enter the date as well as the time on initial set up or if the factory re-set has been used. Having done this, the clock will automatically adjust for BST/GMT time changes throughout the year. Press the set button until the set indicator is next to the clock position to adjust to adjust the to set to set the the hour minutes the date month to set the year Once the year is set and the button is pressed the process is complete and the display will return to the run position Check that the correct time and day are showing in the display. If the wrong day is showing in the display that would indicate that the date has not been set correctly and the above process should be repeated 5

Setting the On and Off Times To alter these settings please proceed as follows:- Press the SET button until SET indicator is next to HW or CH PROG position Use PLUS and MINUS to adjust day Use PLUS and MINUS to adjust 1st ON time Use PLUS and MINUS to adjust 1st time Press Press Press Repeat this process for 2nd and 3rd settings Enter the 3rd time and the word COPY is displayed To follow the copy route and repeat all programmed times for another day go to 1 To set independent times for other days go to 2 1 PLUS and MINUS to select day required COPY. IN is displayed to confirm the copy. Repeat for other days as required To transfer to independent times for other days go to 2 or to finish programming press the SET button until the SET indicator is in the RUN position 2 Press. plus and minus to select the day required. Set 1st, 2nd and 3rd times as before. To repeat for other days go to 2, to copy go to 1 To finish programming press the SET button until the SET indicator is in the RUN position 6 Default Time settings 1st ON 1st 2nd ON 2nd 3rd ON 3rd 6.30AM 8.30AM 12.00 12.00 4.30 10.30 The default time settings shown above are preset at the factory NB. The factory default settings for the 2nd ON/ times are both set at 12:00pm (midday) which cancels this ON period giving 2 ON/ periods for the day. If a midday ON period is required set the 2nd ON and times accordingly. If not press twice.

Resetting the r Electronic equipment can in some circumstances be affected by electrical interference. If the programmer s display becomes frozen or scrambled; or if you wish to revert back to the default time settings please reset by pressing the SET and CH together as shown below. After initial installation it is advisable, before programming the CentaurPlus for the first time, to reset the unit. Resetting can only be achieved with the power ON by pressing the SET and CH together. This will return the programmer to the factory set default times. Press the SET and CH together then release the and the programmer will return to preset factory settings SET CH General Information BATTERY The programmer is fitted with a non-rechargeable, long life battery, which will maintain the programmed time settings for a minimum of ten months with the supply disconnected. THIS SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT. During power interruptions the display will be blank, after 3 days the current time of day will be lost. These measures are to prolong the battery life. SERVICE AND REPAIR This programmer is NOT user serviceable. Please do not dismantle the unit. In the unlikely event of a fault developing please refer to the RESETTING THE PROGRAMMER section of this user guide shown above. If this fails to resolve the problem please contact a local heating engineer or a qualified electrician. 7

What is a programmer?... an explantion for householders. rs allow you to set On and Off time periods. Some models switch the central heating and domestic hot water on and off at the same time; while others allow the domestic hot water and heating to come on and go off at different times. Set the On and Off time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen On and Off heating periods, or be permanently off. The time on the programmer must be correct. Some types have to be adjusted in Spring and Autumn at the changes between Greenwich Mean Time and British Summer Time. You may be able to temporarily adjust the heating programme, for example, Override, Advance or Boost. These are explained in the manufacturer s instructions. The heating will not work if the room thermostat has switched the heating off. And, if you have a hot-water cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature. Email: sales@horstmann.co.uk Website: www.horstmann.co.uk Horstmann Controls Limited, Bristol BS4 1UP 8 Leaflet number P84363 Issue 1