Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Similar documents
R410A50Hz Universal Outdoor Series Technical Manual

MANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

R410A50Hz Universal Outdoor Series Technical Manual

Floor-Standing Type(E Series)

Four-way Cassette Type

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

[U] Serie MHB / MHA Manual de Ingeniería

SERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH

TECHNICAL & SERVICE MANUAL

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type Version. R410A50Hz Universal Outdoor Series Technical Manual LCAC/1.

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

[U] Serie MOV. Manual de Ingeniería

Floor-Standing Type(S2 Series)

DC Inverter Multi-split System Technical Manual - 50Hz/R410a

Service Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM

Service Manual. Air Conditional

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Engineering Data Book

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Engineering Data Book

Window Y9USC/E 09 / 12 / 18 B5R

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

DC Inverter Multi-split System Technical Manual - 50Hz/R410a

Introduction Part 1 : General Information Part 2: Indoor Units Part 3: Installation Part 4: Control

Energy Related Products SUPER DC INVERTER SERIES

MODEL: CCT 301 INV CCT 501 INV CCT 70 INV-S CCT 100 INV-S CCT 140 INV-S CCT 170 INV-S

R410 a. Air Conditioners. Residential and commercial. R410 a

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

SERVICE MANUAL UNI ON/OFF ASC-60A

Ceiling & Floor type Unit

Content. The specifications, designs, and information in this book are subject to change without notice for product improvement.

Aqua Mini Full DC Inverter Unitary Chiller 50Hz. Content

Cassette SERVICE MANUAL. YKHC 18 to 48 YKHC 18 YKHC 24 YKHC 30 YKHC 36 YKHC 48 SM-YKHC-18-48GB 03-07

Engineering Data Book

1. Product Lineup. 2. External Appearance. 3. Nomenclature M R C 36 H W N1 - R. Power supply R: 380~415V 3Ph~ 50Hz. Refrigerant type N1: R410A

MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw)

Service Manual. Air Conditional

SUPER DC INVERTER SERIES

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45

SERVICE MANUAL IOS629C2V01 IOS736C2V01 IUS0736C21 ICS0629C21 ICS0736C21 AIR CONDITIONER

Service manual. MIV V4+ Mini

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

FLUYE CON TU ESTILO DE VIDA

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

CASSETTE TYP FANCOIL UNIT SERVICE MANUAL

Horizontal Water Source Heat Pumps And Cooling Only Unit

Engineering Data Book

1. Features Specification Dimensions Refrigeration cycle diagram Operation limits

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

SKM. Air Conditioners TROPICAL

Engineering Data Book

Air Conditioner Service Manual

LOW STATIC HYDRONIC DUCTED UNIT

Air Conditioner Service Manual

Service Manual & Installation Manual

Ultimate VRF System R410A, 50Hz

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Wall Mounted Split Systems

Blanc ON-OFF Series. Service Manual 2016

Technical Guide. Split Air-Conditioners Equipment Residential COS Series

R410A VRF Indoor Unit 50Hz AC Series

FAN COIL USER MANUAL TC18C2DWB1 TC24C2DWB1 TC37C2DWB1 TC48C2DWB1 TC60C2DWB Innovair Corporation. All Rights Reserved.

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

Multi Inverter Air Conditioning Condensing Units - Summary

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Service Manual & Installation Manual

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

Multi Splits Series. DKH Indoor Units DBC Indoor Units DAQ Indoor Units DCD Indoor Units Outdoor Units JOSI-DKH009-N11

Split Type Air Conditioners FTNE-M Series Cooling Only [50 Hz]

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

R22 air-cooled modular chiller 50Hz unit. Content

MVD. Cassette 4 Ways FCU DC Service manual MUCS-W7. CL04417 to CL04419 English.

DESIGN & TECHNICAL MANUAL

Midea Precision Air Conditioner Technical Manual (Down delivery series)

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

DESIGN & TECHNICAL MANUAL

Multi Split Systems. Reverse Cycle, Inverter Air Conditioner. Exclusively distributed by

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Midea R410A Domestic Pools & Spas Heat Pump Water Heater 50Hz A1 Series Technical Manual

DC INVERTER SERIES. Service Manual 2013 LIS-E-1312

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Transcription:

MCAC-UTSM-2008-11 Contents Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units... 88 Part 4 Installation... 127 Part 5 Control... 136 The specifications, designs, and information in this book are subject to change without notice for product improvement. Contents i

MCAC-UTSM-2008-11 General Information Part 1 General Information 1. Model Names of Indoor/Outdoor Units... 2 2. External Appearance... 3 2.1 Indoor Units... 3 2.2 Outdoor Units... 4 3. Nomenclature... 5 4. Features... 6 General Information 1

Model Names of Indoor/Outdoor Units 1. Model Names of Indoor/Outdoor Units MCAC-UTSM-2008-11 Outdoor unit model Power supply (V-ph-Hz) Compressor type Compressor brand Matched indoor units model MOU-12HN1 220~240-1-50 ROTARY MIDEA-TOSHIBA MCA-12HRN1 MUB-12HRN1 MOUA-18HN1 220~240-1-50 ROTARY MIDEA-TOSHIBA MCA-18HRN1 MUB-18HRN1 MOUA-24HN1 220~240-1-50 ROTARY MIDEA-TOSHIBA MCC-24HRN1 MUB-24HRN1 MOU-30HN1 220~240-1-50 SCROLL SANYO MCC-30HRN1 MUB-30HRN1 MOU-30HN1-R 380~415-3-50 SCROLL SANYO MCC-30HRN1-R MUB-30HRN1 MOU-36HN1 220~240-1-50 SCROLL SANYO MCC-36HRN1 MUB-36HRN1 MOU-36HN1-R 380~415-3-50 SCROLL SANYO MCC-36HRN1-R MUB-36HRN1 MOUA-48HN1-R 380~415-3-50 SCROLL DAIKIN MCC-48HRN1-R MUB-48HRN1-R MOUA-60HN1-R 380~415-3-50 SCROLL SANYO MUB-60HRN1-R 2 General Information

MCAC-UTSM-2008-11 External Appearance 2. External Appearance 2.1 Indoor Units Four-way cassette type (compact) Four-way cassette type Ceiling & floor type Ceiling & floor type General Information 3

External Appearance MCAC-UTSM-2008-11 2.2 Outdoor Units 12,000Btu/h 18,000Btu/h 24,000Btu/h 30,000~36,000Btu/h 48,000Btu/h 60,000Btu/h 4 General Information

MCAC-UTSM-2008-11 3. Nomenclature 3.1 Indoor Unit M C C - 48 H R N1 - R Nomenclature Power Supply R 380~415V, 3N, 50Hz -- 220~240V, 1N, 50Hz Refrigerant Type N1 R410A Control Mode W Wired Control R Remote Control Function Code C Cooling Only H Cooling & Heating Capacity ( 1000Btu/h) Product Series A Time A Designed C Time C Designed B Time B Designed Indoor Unit Type T Duct H High Static Pressure Duct C Cassette U Ceiling & Floor Midea 3.2 Outdoor Unit M O U A - 48 H N1 - R Power Supply R 380V~415V, 3N, 50Hz -- 220~240V, 1N, 50Hz Refrigerant Type N1 R410A Function Code C Cooling Only H Cooling & Heating Capacity ( 1000Btu/h) Product Series A Time A Designed B Time B Designed Universal Outdoor Unit O Outdoor unit U Universal Midea General Information 5

Features MCAC-UTSM-2008-11 4. Features 1. High quality coils: The coil is constructed of advanced inner grooved copper tube and aluminum fins. 2. Anti-rust, 500 hours salt spray test. 3. Low operation sound level: Well-known stable and quiet running fan motor. 4. Well-known compressor. 5. Compact design: Smaller dimension and larger stuffing capacity. 6. Universal outdoor unit design. 7. Optional air outlet grille: plastic type and wire type. Metal grille Plastic type Plastic type 8. Optional low temperature cooling module. 9. R410A environment friendly refrigerant. 6 General Information

MCAC-UTSM-2008-11 Indoor Units Part 2 Indoor Units Four-way Cassette Type (Compact)... 8 Four-way Cassette Type... 21 Ceiling & Floor Type... 53 Indoor Units 7

Four-way Cassette Type (Compact) MCAC-UTSM-2008-11 Four-way Cassette Type (Compact) 1. Features... 9 2. Specifications... 10 3. Dimensions... 11 4. Service Space... 11 5. Wiring Diagram... 12 6. Air Velocity and Temperature Distributions... 13 7. Capacity Tables... 14 8. Electric Characteristics... 16 9. Sound Levels... 16 10. Exploded View... 17 11. Accessories... 18 12. The Specification of Power... 18 13. Field Wiring... 19 8 Indoor Units

MCAC-UTSM-2008-11 1. Features (1) Low operation noise ---Streamline plate ensures quietness ---Creates natural and comfortable environment Features (2) Efficient cooling ---Equal, fast and wide range cooling (3) The adoption of the most advanced 3-Dimensional Screw Fan ---Reduces the air resistance passing through ---Smoothes the air flow ---Makes air speed distribution to the heat exchange uniform (4) Improvement for easy installation and maintenance ---Little space is required for installation into a shallow ceiling ---Because of the compactness and weight reduction of the main unit and panel, all models can be installed without a hoist Indoor Units 9

Specifications MCAC-UTSM-2008-11 2. Specifications Model MCA-12HRN1 MCA-18HRN1 Code 220042002960 220042001870 Power supply V-ph-Hz 220~240-1-50 220~240-1-50 Cooling Heating Indoor fan motor Indoor coil Capacity kw 3.2 5.3 Input W 1100 1900 Capacity kw 4 6 Input W 1050 1900 Model YDK45-4F YDK45-4F Brand Welling Welling Input W 56.7/51.5/44.4 56.7/51.5/44.4 Capacitor uf 1.5uF/450V 2.5uF/450V Speed(Hi/Mi/Lo) r/min 930/845/680 930/845/680 Number of rows 2 2 Tube pitch(a) row pitch(b) mm 21 13.37 21 13.37 Fin spacing mm 1.4 1.4 Fin type (code) Hydrophilic aluminium Hydrophilic aluminium Tube outside dia.and type mm φ7 Inner grooved copper tube φ7 Inner grooved copper tube Coil length height width mm 1215 210 26.74 1215 210 26.74 Number of circuits 5 5 Indoor air flow (Hi/Mi/Lo) m 3 /h 680/600/400 860/760/500 Indoor noise level (sound pressure) db(a) 41/38/35 42.5/39.4/35.8 Indoor unit Dimension (W H D)(body) mm 580 254 580 580 254 580 Packing (W H D)(body) mm 750 340 745 750 340 745 Dimension (W H D)(panel) mm 650 30 650 650 30 650 Packing (W H D)(panel) mm 715 115 715 715 115 715 Net/Gross weight(body) kg 21/28 21/27 Net/Gross weight(panel) kg 3/5 3/5 Refrigerant type R410A R410A Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/ Gas side mm φ6.4/φ12.7 φ6.4/φ12.7 Drainage water pipe diameter mm ODφ25 ODφ25 Connection wiring Power wiring mm 2 3 2.5 3 2.5 Strong electric signal wiring mm 2 5 2.5 5 2.5 Weak electric signal wiring mm 2 1-core shield wire 1 0.5 1-core shield wire 1 0.5 Controller R11HG/E(standard) R11HG/E(standard) Operation temperature 17-30 17-30 Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27 CDB, 19 CWB; Outdoor temp: 35 CDB; 2. Nominal heating capacities are based on the following conditions: Indoor temp: 20 CDB; Outdoor temp: 7 CDB, 6 CWB; 3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room. 10 Indoor Units

MCAC-UTSM-2008-11 3. Dimensions Dimensions 4. Service Space Indoor Units 11

Wiring Diagram 5. Wiring Diagram MCAC-UTSM-2008-11 12 Indoor Units

MCAC-UTSM-2008-11 6. Air Velocity and Temperature Distributions Air Velocity and Temperature Distributions Airflow velocity Temperature Indoor Units 13

Capacity Tables MCAC-UTSM-2008-11 7. Capacity Tables 7.1 Cooling Capacity MCA-12HRN1 Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC TC 3.30 3.14 2.98 2.85 21/15ºC DB/WB SC 2.44 2.41 2.38 2.39 Input 0.91 0.99 1.03 1.07 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB MCA-18HRN1 Cooling TC 3.39 3.23 3.07 2.88 SC 2.54 2.52 2.49 2.42 Input 0.97 1.03 1.08 1.13 TC 3.46 3.30 3.20 2.98 SC 2.56 2.54 2.50 2.44 Input 0.99 1.05 1.10 1.16 TC 3.52 3.39 3.33 3.07 SC 2.99 2.95 2.93 2.86 Input 1.03 1.08 1.16 1.20 Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC 21/15ºC DB/WB 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB TC 5.46 5.19 4.93 4.72 SC 4.04 4.00 3.94 3.96 Input 1.58 1.71 1.79 1.84 TC 5.62 5.35 5.09 4.77 SC 4.21 4.18 4.12 4.01 Input 1.67 1.79 1.86 1.96 TC 5.72 5.46 5.30 4.93 SC 4.24 4.20 4.13 4.04 Input 1.71 1.81 1.90 2.00 TC 5.83 5.62 5.51 5.09 SC 4.96 4.89 4.85 4.73 Input 1.79 1.86 2.00 2.07 14 Indoor Units

MCAC-UTSM-2008-11 Capacity Tables 7.2 Heating Capacity MCA-12HRN1 Heating Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB TC 5.20 4.20 3.44 3.12 15ºC Input 1.13 0.98 0.84 0.79 20ºC 27ºC MCA-18HRN1 Heating TC 5.04 4.00 3.24 3.04 Input 1.24 1.05 0.92 0.85 TC 4.72 3.76 3.04 2.96 Input 1.31 1.13 1.00 0.92 Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB TC 7.80 6.30 5.16 4.68 15ºC Input 2.05 1.77 1.52 1.43 20ºC 27ºC Remark: TC: Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw TC 7.56 6.00 4.86 4.56 Input 2.24 1.90 1.67 1.54 TC 7.08 5.64 4.56 4.44 Input 2.38 2.05 1.81 1.67 Indoor Units 15

Electric Characteristics MCAC-UTSM-2008-11 8. Electric Characteristics Model Indoor Units Power Supply Indoor Fan Motor Hz Voltage Min. Max. MCA MFA kw FLA MCA-12HRN1 50 220-240V 198V 254V 0.33 25 0.045 0.264 MCA-18HRN1 50 220-240V 198V 254V 0.33 25 0.045 0.264 Remark: MCA: Min. Current Amps. (A) MFA: Max. Fuse Amps. (A) KW: Fan Motor Rated Output (kw) FLA: Full Load Amps. (A) 9. Sound Levels FOUR-WAY CASSETTE TYPE 1.0m Microphone Model Noise level db(a) H M L MCA-12HRN1 41 38 35 MCA-18HRN1 42.5 39.4 35.8 16 Indoor Units

MCAC-UTSM-2008-11 10. Exploded View MCA-12HRN1 MCA-18HRN1 Exploded View 10.5 No. Part Name Quantity No. Part Name Quantity 1 Drainage pan ass'y 1 11 E-Part box cover 1 2 Centrifugal fan 1 12 Drain pump Holder 1 3 Installation bracket 4 13 Drain pump 1 4 Evaporator fixing hanger 1 14 Right clapboard ass'y 1 5 Motor 1 15 Partition board 1 6 Motor base 1 16 Evaporator fixing board ass'y 1 7 Base ass'y 1 17 Evaporator ass'y 1 8 Board 1 18 Evaporator temp. sensor ass'y 1 9 Sealed board ass'y 1 19 Room temp. sensor ass'y 1 10 E-part box ass'y 1 20 Remote controller 1 10.1 Main controller ass'y 1 21 Remote controller holder 1 10.2 Motor capacitor 1 22 Panel ass'y 1 10.3 Wire joint, 7p 1 22.1 Swing motor 1 10.4 Wire joint 1 22.2 Display board 1 10.5 Transformer 1 Indoor Units 17

Accessories 11. Accessories Installation fittings MCAC-UTSM-2008-11 Name Shape Quantity 1. Expansible hook 4 2. Installation hook 4 3. Installation paper board 1 4. Out-let pipe sheath 1 Drainpipe Fittings 5. Out-let pipe clasp 1 6. Tightening band 20 7. Drain joint 1 8. Remote controller 1 Remote controller & Its holder 9. Remote controller holder 1 10. Mounting screw(st2.9 10-C-H) 2 11. Alkaline dry batteries (AM4) 2 Others 12. Owner's manual 1 13. Installation manual 1 12. The Specification of Power Type MCA-12HRN1 MCA-18HRN1 Power Phase 1-phase 1-phase Frequency and Voltage 220-240V, 50Hz 220-240V, 50Hz Circuit Breaker/ Fuse (A) 40/25 40/25 Indoor Unit Power Wiring (mm 2 ) 3 2.5 3 2.5 Indoor/Outdoor Connecting Wiring 2.5 2.5 2.5 Outdoor Unit Power Wiring Strong Electric Signal 5 2.5 5 2.5 Weak Electric Signal 1-core shield wire 1 0.5 1-core shield wire 1 0.5 18 Indoor Units

MCAC-UTSM-2008-11 13. Field Wiring Field Wiring MCA-12HRN1 Indoor Units 19

Field Wiring MCAC-UTSM-2008-11 MCA-18HRN1 20 Indoor Units

MCAC-UTSM-2008-11 Four-way Cassette Type Four-way Cassette Type 1. Features... 22 2. Specifications... 24 3. Dimensions... 27 4. Service Space... 28 5. Wiring Diagrams... 29 6. Air Velocity and Temperature Distributions... 31 7. Capacity Tables... 32 8. Electric Characteristics... 38 9. Sound Levels... 38 10. Exploded View... 39 11. Accessories... 51 12. The Specification of Power... 51 13. Field Wiring... 52 Indoor Units 21

Features 1. Features (1) Ultra thin machine body to easy installation and maintenance. 24K:230mm, 30-48K:300mm. MCAC-UTSM-2008-11 (2) Different color panels to choose: White, Gray, Blue, Black (3) The swing angle of the first louver are 40~42 degrees and the second louver are 37~38 degrees. (4) 4 speeds available, optional super high fan speed design, suitable for the large building over 3m high. (5) Adding digital tube displaying on the display board. LED can display the Error Code to make the malfunction checking easier. (6) Reserve spaces for air side-outlet, it is available to connect duct pipe hence Air supplying from the four sides to nearby small room. 22 Indoor Units

MCAC-UTSM-2008-11 Features (7) Stylish design is harmonious with any interior decoration and creates and elegant environment. (8) Built-in water pump with 750mm pumping head. (9) Fresh air makes life more healthy and comfortable. Indoor Units 23

Specifications MCAC-UTSM-2008-11 2. Specifications Model MCC-24HRN1 MCC-30HRN1 Code 220042500390 220042600250 Power supply V-ph-Hz 220~240-1-50 220~240-1-50 Cooling Heating Indoor fan motor Indoor coil Capacity kw 7.1 9.0 Input W 2700 3500 Capacity kw 7.6 9.5 Input W 2800 3600 Model YDK80-6E YDK90-6E Brand Welling Welling Input W 120/110/100/90 165/143/116/100 Capacitor uf 3.5uF/450V 3.5uF/450V Speed(Hi/Mi/Lo) r/min 800/670/550/400 840/770/640/550 Number of rows 2 2 Tube pitch(a) row pitch(b) mm 21 13.37 21 13.37 Fin spacing mm 1.5 1.5 Fin type (code) Hydrophilic aluminum Hydrophilic aluminium Tube outside dia.and type mm φ7 Inner grooved copper tube φ7 Inner grooved copper tube Coil length height width mm 1959.4 168 26.74 1959.4 252 26.74 Number of circuits 16 12 Indoor air flow (Hi/Mi/Lo) m 3 /h 1220/1010/822 1538/1296/1124 Indoor noise level (sound pressure) db(a) 48/44/40 50/46//42 Indoor unit Dimension (W H D)(body) mm 840 230 840 840 300 840 Packing (W H D)(body) mm 955 247 955 955 317 955 Dimension (W H D)(panel) mm 950 55 950 950 55 950 Packing (W H D)(panel) mm 1035 90 1035 1035 90 1035 Net/Gross weight(body) kg 29/36 35/42 Net/Gross weight(panel) kg 6/9 6/9 Refrigerant type R410A R410A Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/gas side mm φ9.5/φ15.9 φ12.7/φ19 Drainage water pipe diameter mm ODφ32 ODφ32 Connection wiring Power wiring mm 2 3 4.0 3 4.0 Strong electric signal wiring mm 2 3 2.5 3 2.5 Weak electric signal wiring mm 2 1-core shield wire 1 0.5 1-core shield wire 1 0.5 Controller R05/BGE(standard) R05/BGE(standard) Operation temperature 17-30 17-30 Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27 CDB, 19 CWB; Outdoor temp: 35 CDB; 2. Nominal heating capacities are based on the following conditions: Indoor temp: 20 CDB; Outdoor temp: 7 CDB, 6 CWB; 3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room. 24 Indoor Units

MCAC-UTSM-2008-11 Specifications Model MCC-30HRN1-R MCC-36HRN1 Code 220042600270 220042700210 Power supply V-ph-Hz 380~415-3-50 220~240-1-50 Cooling Heating Indoor fan motor Indoor coil Capacity kw 9.0 10.5 Input W 3500 3850 Capacity kw 9.5 12.0 Input W 3700 4050 Model YDK90-6E YDK90-6E Brand Welling Welling Input W 165/143/116/100 165/143/116/100 Capacitor uf 3.5uF/450V 3.5uF/450V Speed(Hi/Mi/Lo) r/min 840/770/640/550 840/770/640/550 Number of rows 2 2 Tube pitch(a) row pitch(b) mm 21 13.37 21 13.37 Fin spacing mm 1.5 1.5 Fin type (code) Hydrophilic aluminum Hydrophilic aluminum Tube outside dia.and type mm φ7 Inner grooved copper tube φ7 Inner grooved copper tube Coil length height width mm 1959.4 252 26.74 1959.4 252 26.74 Number of circuits 12 12 Indoor air flow (Hi/Mi/Lo) m 3 /h 1538/1296/1124 1538/1296/1124 Indoor noise level (sound pressure) db(a) 50/46//42 50/46//42 Indoor unit Dimension (W H D)(body) mm 840 300 840 840 300 840 Packing (W H D)(body) mm 955 317 955 955 317 955 Dimension (W H D)(panel) mm 950 55 950 950 55 950 Packing (W H D)(panel) mm 1035 90 1035 1035 90 1035 Net/Gross weight(body) kg 35/42 35/42 Net/Gross weight(panel) kg 6/9 6/9 Refrigerant type R410A R410A Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/gas side mm φ12.7/φ19 φ12.7/φ19 Drainage water pipe diameter mm ODφ32 ODφ32 Connection wiring Power wiring mm 2 5 2.5 3 4.0 Strong electric signal wiring mm 2 3 1.0 3 2.5 Weak electric signal wiring mm 2 1-core shield wire 1 0.5 Controller R05/BGE(standard) R05/BGE(standard) Operation temperature 17-30 17-30 Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27 CDB, 19 CWB; Outdoor temp: 35 CDB; 2. Nominal heating capacities are based on the following conditions: Indoor temp: 20 CDB; Outdoor temp: 7 CDB, 6 CWB; 3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room. Indoor Units 25

Specifications MCAC-UTSM-2008-11 Model MCC-36HRN1-R MCC-48HRN1-R Code 220042700230 220042800310 Power supply V-ph-Hz 380~415-3-50 380~415-3-50 Cooling Heating Indoor fan motor Indoor coil Capacity kw 10.5 14 Input W 3850 4881 Capacity kw 12.0 15 Input W 4100 4941 Model YDK90-6E YDK90-6E Brand Welling Welling Input W 165/143/116/100 165/143/116/100 Capacitor uf 3.5uF/450V 3.5uF/450V Speed(Hi/Mi/Lo) r/min 840/770/640/550 840/770/640/550 Number of rows 2 2 Tube pitch(a) row pitch(b) mm 21 13.37 21 13.37 Fin spacing mm 1.5 1.5 Fin type (code) Hydrophilic aluminum Hydrophilic aluminum Tube outside dia.and type mm φ7 Inner grooved copper tube φ7 Inner grooved copper tube Coil length height width mm 1959.4 252 26.74 1959.4 252 26.74 Number of circuits 12 12 Indoor air flow (Hi/Mi/Lo) m 3 /h 1538/1296/1124 1538/1296/1124 Indoor noise level (sound pressure) db(a) 50/46//42 50/46//42 Indoor unit Dimension (W H D)(body) mm 840 300 840 840 300 840 Packing (W H D)(body) mm 955 317 955 955 317 955 Dimension (W H D)(panel) mm 950 55 950 950 55 950 Packing (W H D)(panel) mm 1035 90 1035 1035 90 1035 Net/Gross weight(body) kg 35/42 35/42 Net/Gross weight(panel) kg 6/9 6/9 Refrigerant type R410A R410A Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/gas side mm φ12.7/φ19 φ12.7/φ19 Drainage water pipe diameter mm ODφ32 ODφ32 Connection wiring Power wiring mm 2 5 2.5 5 2.5 Strong electric signal wiring mm 2 3 1.0 3 1.0 Weak electric signal wiring mm 2 Controller R05/BGE(standard) R05/BGE(standard) Operation temperature 17-30 17-30 Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27 CDB, 19 CWB; Outdoor temp: 35 CDB; 2. Nominal heating capacities are based on the following conditions: Indoor temp: 20 CDB; Outdoor temp: 7 CDB, 6 CWB; 3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room. 26 Indoor Units

MCAC-UTSM-2008-11 3. Dimensions 3.1 MCC-24HRN1 Dimensions 3.2 MCC-30HRN1 MCC-30HRN1-R MCC-36HRN1 MCC-36HRN1-R MCC-48HRN1-R Indoor Units 27

Service Space 4. Service Space The indoor unit should be installed in a location that meets the following requirements: There is enough room for installation and maintenance. The ceiling is horizontal, and its structure can endure the weight of the indoor unit. The outlet and the inlet are not impeded, and the influence of external air is the least. The air flow can reach throughout the room. The connecting pipe and drainpipe could be extracted out easily. There is no direct radiation from heaters. MCAC-UTSM-2008-11 28 Indoor Units

MCAC-UTSM-2008-11 5. Wiring Diagrams 5.1 MCC-24HRN1 MCC-30HRN1 MCC-36HRN1 Wiring Diagrams Indoor Units 29

Wiring Diagrams MCAC-UTSM-2008-11 5.2 MCC-30HRN1-R MCC-36HRN1-R MCC-48HRN1-R 30 Indoor Units

MCAC-UTSM-2008-11 6. Air Velocity and Temperature Distributions Air Velocity and Temperature Distributions Airflow velocity Temperature Indoor Units 31

Capacity Tables 7. Capacity Tables MCC-24HRN1 Cooling Cooling Outdoor conditions (DB) MCAC-UTSM-2008-11 Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC 21/15ºC DB/WB 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB TC 7.31 6.96 6.60 6.32 SC 5.41 5.36 5.28 5.31 Input 2.24 2.43 2.54 2.62 TC 7.53 7.17 6.82 6.39 SC 5.64 5.59 5.52 5.37 Input 2.38 2.54 2.65 2.78 TC 7.67 7.31 7.10 6.60 SC 5.67 5.63 5.54 5.41 Input 2.43 2.57 2.70 2.84 TC 7.81 7.53 7.38 6.82 SC 6.64 6.55 6.50 6.34 Input 2.54 2.65 2.84 2.94 Heating Heating Indoor Conditions (DB) 15ºC 20ºC 27ºC Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw Outdoor conditions (kw) 24/18ºC 7/6ºC 2/1ºC -5/-6ºC DB/WB DB/WB DB/WB DB/WB TC 9.88 7.98 6.54 5.93 Input 3.02 2.60 2.24 2.10 TC 9.58 7.60 6.16 5.78 Input 3.30 2.80 2.46 2.27 TC 8.97 7.14 5.78 5.62 Input 3.50 3.02 2.66 2.46 32 Indoor Units

MCAC-UTSM-2008-11 Capacity Tables MCC-30HRN1 Cooling Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC TC 9.27 8.82 8.37 8.01 21/15ºC DB/WB SC 6.86 6.79 6.70 6.73 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB Input 2.91 3.15 3.29 3.40 TC 9.54 9.09 8.64 8.10 SC 7.16 7.09 7.00 6.80 Input 3.08 3.29 3.43 3.61 TC 9.72 9.27 9.00 8.37 SC 7.19 7.14 7.02 6.86 Input 3.15 3.33 3.50 3.68 TC 9.90 9.54 9.36 8.64 SC 8.42 8.30 8.24 8.04 Input 3.29 3.43 3.68 3.82 Heating Heating Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB TC 12.35 9.98 8.17 7.41 15ºC Input 3.89 3.35 2.88 2.70 20ºC TC 11.97 9.50 7.70 7.22 Input 4.25 3.60 3.17 2.92 TC 11.21 8.93 7.22 7.03 27ºC Input 4.50 3.89 3.42 3.17 Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw Indoor Units 33

Capacity Tables MCAC-UTSM-2008-11 MCC-30HRN1-R Cooling Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC TC 9.27 8.82 8.37 8.01 21/15ºC DB/WB SC 6.86 6.79 6.70 6.73 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB Input 2.91 3.15 3.29 3.40 TC 9.54 9.09 8.64 8.10 SC 7.16 7.09 7.00 6.80 Input 3.08 3.29 3.43 3.61 TC 9.72 9.27 9.00 8.37 SC 7.19 7.14 7.02 6.86 Input 3.15 3.33 3.50 3.68 TC 9.90 9.54 9.36 8.64 SC 8.42 8.30 8.24 8.04 Input 3.29 3.43 3.68 3.82 Heating Heating Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB TC 12.35 9.98 8.17 7.41 15ºC Input 4.00 3.44 2.96 2.78 20ºC TC 11.97 9.50 7.70 7.22 Input 4.37 3.70 3.26 3.00 TC 11.21 8.93 7.22 7.03 27ºC Input 4.63 4.00 3.52 3.26 Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw 34 Indoor Units

MCAC-UTSM-2008-11 Capacity Tables MCC-36HRN1 Cooling Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC TC 10.82 10.29 9.77 9.35 21/15ºC DB/WB SC 8.00 7.92 7.81 7.85 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB Input 3.20 3.47 3.62 3.73 TC 11.13 10.61 10.08 9.45 SC 8.35 8.27 8.16 7.94 Input 3.39 3.62 3.77 3.97 TC 11.34 10.82 10.50 9.77 SC 8.39 8.33 8.19 8.01 Input 3.47 3.66 3.850 4.04 TC 11.55 11.13 10.92 10.08 SC 9.82 9.68 9.61 9.37 Input 3.62 3.77 4.04 4.20 Heating Heating Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB TC 15.60 12.60 10.32 9.36 15ºC Input 4.37 3.77 3.24 3.04 20ºC TC 15.12 12.00 9.72 9.12 Input 4.78 4.05 3.56 3.28 TC 14.16 11.28 9.12 8.88 27ºC Input 5.06 4.37 3.85 3.56 Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw Indoor Units 35

Capacity Tables MCAC-UTSM-2008-11 MCC-36HRN1-R Cooling Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC TC 10.82 10.29 9.77 9.35 21/15ºC DB/WB SC 8.00 7.92 7.81 7.85 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB Input 3.20 3.47 3.62 3.73 TC 11.13 10.61 10.08 9.45 SC 8.35 8.27 8.16 7.94 Input 3.39 3.62 3.77 3.97 TC 11.34 10.82 10.50 9.77 SC 8.39 8.33 8.19 8.01 Input 3.47 3.66 3.850 4.04 TC 11.55 11.13 10.92 10.08 SC 9.82 9.68 9.61 9.37 Input 3.62 3.77 4.04 4.20 Heating Heating Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB TC 15.60 12.60 10.32 9.36 15ºC Input 4.43 3.81 3.28 3.08 20ºC TC 15.12 12.00 9.72 9.12 Input 4.84 4.10 3.61 3.32 TC 14.16 11.28 9.12 8.88 27ºC Input 5.13 4.43 3.90 3.61 Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw 36 Indoor Units

MCAC-UTSM-2008-11 Capacity Tables MCC-48HRN1-R Cooling Heating Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC 21/15ºC DB/WB 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB Heating TC 14.42 13.72 13.02 12.46 SC 10.67 10.56 10.42 10.47 Input 4.05 4.39 4.59 4.73 TC 14.84 14.14 13.44 12.60 SC 11.13 11.03 10.89 10.58 Input 4.30 4.59 4.78 5.03 TC 15.12 14.42 14.00 13.02 SC 11.19 11.10 10.92 10.68 Input 4.39 4.64 4.881 5.13 TC 15.40 14.84 14.56 13.44 SC 13.09 12.91 12.81 12.50 Input 4.59 4.78 5.13 5.32 Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB 15ºC 20ºC 27ºC Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw TC 19.50 15.75 12.90 11.70 Input 5.34 4.60 3.95 3.71 TC 18.90 15.00 12.15 11.40 Input 5.83 4.941 4.35 4.00 TC 17.70 14.10 11.40 11.10 Input 6.18 5.34 4.69 4.35 Indoor Units 37

Electric Characteristics MCAC-UTSM-2008-11 8. Electric Characteristics Model Indoor Units Power Supply Indoor Fan Motor Hz Voltage Min. Max. MCA MFA kw FLA MCC-24HRN1 50 220-240V 198V 254V 0.7 25 0.065 0.56 MCC-30HRN1 50 220-240V 198V 254V 0.955 25 0.090 0.8 MCC-30HRN1-R 50 380-415V 342V 418V 0.955 15 0.090 0.8 MCC-36HRN1 50 220-240V 198V 254V 0.955 25 0.090 0.8 MCC-36HRN1-R 50 380-415V 342V 418V 0.955 15 0.090 0.8 MCC-48HRN1-R 50 380-415V 342V 418V 0.955 15 0.090 0.8 Remark: MCA: Min. Current Amps. (A) MFA: Max. Fuse Amps. (A) KW: Fan Motor Rated Output (kw) FLA: Full Load Amps. (A) 9. Sound Levels FOUR-WAY CASSETTE TYPE 1.0m Microphone Model Noise level db(a) H M L MCC-24HRN1 48 44 40 MCC-30HRN1/MCC-30HRN1-R 50 46 42 MCC-36HRN1/MCC-36HRN1-R 50 46 42 MCC-48HRN1-R 50 46 42 38 Indoor Units

MCAC-UTSM-2008-11 10. Exploded View 10.1 MCC-24HRN1 Exploded View 33 Indoor Units 39

Exploded View MCAC-UTSM-2008-11 No. Part Name Quantity No. Part Name Quantity 1 Electricity control box coping I 1 12 Motor 1 2 Electricity control box coping II 1 13 Base 1 3 E-part box ass'y 1 14 Wire clamp 1 3.1 E-part box 1 15 Panel 1 3.2 Transformer 1 16 Wire clamp 1 3.3 Room temp. sensor ass'y 1 17 Wire clip 1 3.4 Motor capacitor 1 18 Evaporator fixing hanger 3 3.5 Main controller 1 19 Water pump board 1 3.6 Wire joint 1 20 Drain pump 1 3.7 Wire joint, 3p 1 21 Installation bracket ass'y 1 4 Air guide ring ass'y 1 22 Board ass'y 1 5 Foam ass'y 1 23 Water pipe clamp 1 6 Fan ass'y 1 24 Fan clip 1 7 Evaporator fixing board 1 25 Water cover ass'y 1 8 Evaporator ass'y 1 26 Board ass'y 1 8.1 Evaporator 1 26.1 Hook 2 8.2 Evaporator output pipe ass'y 1 27 Water pipe 1 8.3 Evaporator input pipe ass'y 1 28 Sealed board ass'y 1 8.4 Sleeve 1 29 Pump rubber washer 3 9 Board ass'y 1 30 Remote controller 1 9.1 Hook 2 31 Installation bracket 1 10 Foam ass'y 1 32 Evaporator temp. sensor 1 11 Board ass'y 1 33 Water-level sensor ass y 1 40 Indoor Units

MCAC-UTSM-2008-11 Exploded View 10.2 MCC-30HRN1 Indoor Units 41

Exploded View MCAC-UTSM-2008-11 No. Part Name Quantity No. Part Name Quantity 1 Electric control box head cover I 1 13 Base pan seat 1 2 Electric control box head cover II 1 14 Base pan welded assembly 1 3 Electric control box assembly of indoor unit 1 15 Plate, wire 1 3.1 Electric control box welded assembly 1 16 Tandem, wire 1 3.2 Voltage transformer 1 17 Bipitch wire clip 1 3.3 Indoor temp. sensor subassembly 1 18 Evaporator fixing hook 3 3.4 Capacitor 1 19 Water pump baffle plate 1 3.5 Four sides air outlet indoor main control plate 1 20 Water drain pump subassembly 1 4 Air inducting coils subassembly 1 21 Water pump installation bracket subassembly 1 5 Foam subassembly,drip tray 1 22 Front barrier IV subassembly 1 6 Fan assembly 1 23 Water pump pumping pipe grommet 1 7 Evaporator fixing board 1 24 Fan fins 1 8 Evaporator assembly 1 25 Install lifting lug 4 8.1 Evaporator 1 26 Water finder cover subassembly 1 8.2 Evaporator output tube assembly 1 27 Front barrier III subassembly 1 8.3 Evaporator filter assembly 1 28 Water pumping connect pipe 1 8.4 Barrel 1 29 Exhalant tube seal plate subassembly 1 9 Front barrier I subassembly 1 30 Water pump's rubber pad 1 10 Foam seat subassembly 1 31 Remote controller 1 11 Front barrier II subassembly 1 32 Bracket, remote controller 1 12 Asynchronous dynamo 1 33 Front panel 1 42 Indoor Units

MCAC-UTSM-2008-11 Exploded View 10.3 MCC-30HRN1 -R Indoor Units 43

Exploded View MCAC-UTSM-2008-11 No. Part Name Quantity No. Part Name Quantity 1 Electric control box head cover I 1 13 Base pan seat 1 2 Electric control box head cover II 1 14 Base pan welded assembly 1 3 Electric control box assembly of indoor unit 1 15 Plate, wire 1 3.1 Electric control box welded assembly 1 16 Tandem, wire 1 3.2 Voltage transformer 1 17 Bipitch wire clip 1 3.3 Indoor temp. sensor subassembly 1 18 Evaporator fixing hook 3 3.4 Capacitor 1 19 Water pump baffle plate 1 3.5 Four sides air outlet indoor main control plate 1 20 Water drain pump subassembly 1 4 Air inducting coils subassembly 1 21 Water pump installation bracket subassembly 1 5 Foam subassembly,drip tray 1 22 Front barrier IV subassembly 1 6 Fan assembly 1 23 Water pump pumping pipe grommet 1 7 Evaporator fixing board 1 24 Fan fins 1 8 Evaporator assembly 1 25 Install lifting lug 4 8.1 Evaporator 1 26 Water finder cover subassembly 1 8.2 Evaporator output tube assembly 1 27 Front barrier III subassembly 1 8.3 Evaporator filter assembly 1 28 Water pumping connect pipe 1 8.4 Barrel 1 29 Exhalant tube seal plate subassembly 1 9 Front barrier I subassembly 1 30 water pump's rubber pad 1 10 Foam seat subassembly 1 31 Remote controller 1 11 Front barrier II subassembly 1 32 Bracket, remote controller 1 12 Asynchronous dynamo 1 33 Front panel 1 44 Indoor Units

MCAC-UTSM-2008-11 Exploded View 10.4 MCC-36HRN1 Indoor Units 45

Exploded View MCAC-UTSM-2008-11 No. Part Name Quantity No. Part Name Quantity 1 Electric control box head cover I 1 13 Base pan seat 1 2 Electric control box head cover II 1 14 Base pan welded assembly 1 3 Electric control box assembly of indoor unit 1 15 Plate, wire 1 3.1 Electric control box welded assembly 1 16 Tandem, wire 1 3.2 Voltage transformer 1 17 Bipitch wire clip 1 3.3 Indoor temp. sensor subassembly 1 18 Evaporator fixing hook 3 3.4 Capacitor 1 19 Water pump baffle plate 1 3.5 Four sides air outlet indoor main control plate 1 20 Water drain pump subassembly 1 4 Air inducting coils subassembly 1 21 Water pump installation bracket subassembly 1 5 Foam subassembly,drip tray 1 22 Front barrier IV subassembly 1 6 Fan assembly 1 23 Water pump pumping pipe grommet 1 7 Evaporator fixing board 1 24 fan fins 1 8 Evaporator assembly 1 25 Install lifting lug 4 8.1 Evaporator 1 26 Water finder cover subassembly 1 8.2 Evaporator output tube assembly 1 27 Front barrier III subassembly 1 8.3 Evaporator filter assembly 1 28 Water pumping connect pipe 1 8.4 Barrel 1 29 Exhalant tube seal plate subassembly 1 9 Front barrier I subassembly 1 30 Water pump's rubber pad 1 10 Foam seat subassembly 1 31 Remote controller 1 11 Front barrier II subassembly 1 32 Bracket, remote controller 1 12 Asynchronous dynamo 1 33 Front panel 1 46 Indoor Units

MCAC-UTSM-2008-11 Exploded View 10.5 MCC-36HRN1-R Indoor Units 47

Exploded View MCAC-UTSM-2008-11 No. Part Name Quantity No. Part Name Quantity 1 Electric control box head cover I 1 13 Base pan seat 1 2 Electric control box head cover II 1 14 Base pan welded assembly 1 3 Electric control box assembly of indoor unit 1 15 Plate, wire 1 3.1 Electric control box welded assembly 1 16 Tandem, wire 1 3.2 Voltage transformer 1 17 Bipitch wire clip 1 3.3 Indoor temp. sensor subassembly 1 18 Evaporator fixing hook 3 3.4 Capacitor 1 19 Water pump baffle plate 1 3.5 Four sides air outlet indoor main control plate 1 20 Water drain pump subassembly 1 4 Air inducting coils subassembly 1 21 Water pump installation bracket subassembly 1 5 Foam subassembly,drip tray 1 22 Front barrier IV subassembly 1 6 Fan assembly 1 23 Water pump pumping pipe grommet 1 7 Evaporator fixing board 1 24 Fan fins 1 8 Evaporator assembly 1 25 Install lifting lug 4 8.1 Evaporator 1 26 Water finder cover subassembly 1 8.2 Evaporator output tube assembly 1 27 Front barrier III subassembly 1 8.3 Evaporator filter assembly 1 28 Water pumping connect pipe 1 8.4 Barrel 1 29 Exhalant tube seal plate subassembly 1 9 Front barrier I subassembly 1 30 Water pump's rubber pad 1 10 Foam seat subassembly 1 31 Remote controller 1 11 Front barrier II subassembly 1 32 Bracket, remote controller 1 12 Asynchronous dynamo 1 33 Front panel 1 48 Indoor Units

MCAC-UTSM-2008-11 Exploded View 10.6 MCC-48HRN1-R 3/3.2/3.3/3.4/3.5/3.6/3.7 33 34 32 Indoor Units 49

Exploded View MCAC-UTSM-2008-11 No. Part Name Quantity No. Part Name Quantity 1 Electricity control box coping I 1 13 Chassis pillow 1 2 Electricity control box coping II 1 14 Chassis Ass'y 1 3 Electric control assy subassembly 1 15 Plate, wire 1 3.1 E-part box 1 16 Panel 1 3.2 Transformer 1 17 Plate, wire 1 3.3 Indoor temp. sensor subassembly 1 18 Bipitch wire clip 1 3.4 Motor capacitor 1 19 Fixing hanger, evaporator 3 3.5 Main controller subassembly 1 20 Water pump baffle 1 3.6 Wire joint, 6p 1 21 Drain pump 1 3.7 Wire joint, 6p 1 22 Water Pump installation subassembly 1 4 Guide wind circle subassembiy 1 23 Boarding subassembly Ⅳ 1 5 Foam subassembly,drip tray 1 24 Water pipe clamp 1 6 Wind wheel assembly 1 25 Clip, wind wheel 1 7 Fixing board, Evaporator 1 26 water finder cover subassembly 1 8 Evaporator assembly 1 27 Boarding subassembly Ⅲ 1 8.1 Evaporator 1 27.1 Installation hanger 2 8.2 Gas output pipe, evaporator, assembly 1 28 Extended water pipe 1 8.3 Eva filter, assmy assembly 1 29 Sealing board for pipe tie-in subassembly 1 8.4 Sleeve 1 30 Rubber washer, pump 1 9 Boarding subassembly I 1 31 Remote controller 1 9.1 Installation hanger 2 32 Holder 1 10 Foam subassembly, Base 1 33 Evaporator temp. sensor 1 11 boarding subassembly II 1 34 Water-level sensor ass y 1 12 Asynchronism motor 1 50 Indoor Units

MCAC-UTSM-2008-11 11. Accessories Installation Fittings Tubing & Fittings Drainpipe Fittings Protect Pipe Fittings Accessories Name Shape Quantity 1. Expansible hook 4 2. Installation hook 4 3. Installation paper board 1 4. Bolt M5 4 5. Connecting pipe group 1 6. Binding tape 6 7.Soundproof/insulation sheath 2 8. Out-let pipe sheath 1 9. Out-let pipe clasp 1 10. Tightening band 20 11. Drain joint 1 12. Seal ring 1 13. Wall conduit 1 14. Wall conduit cover 1 15. Remote controller 1 Remote controller & Its Frame Others 16. Frame 1 17. Mounting screw(st2.9 10-C-H) 2 18. Alkaline dry batteries (AM4) 2 19. Owner's manual 1 20. Installation manual 1 12. The Specification of Power Type MCC-24HRN1 MCC-30HRN1 MCC-30HRN1-R Phase 1-phase 1-phase 3-phase Power Frequency and Voltage 220-240V, 50Hz 220-240V, 50Hz 380-415V, 50Hz Circuit Breaker/ Fuse (A) 40/25 40/25 25/15 Indoor Unit Power Wiring (mm 2 ) 3 4.0 3 4.0 5 2.5 Ground Wiring 4.0 4.0 2.5 Outdoor Unit Power Wiring 3 4.0 3 4.0 5 2.5 Strong Electric Signal 3 2.5 3 2.5 3 1.0 Indoor/Outdoor Connecting Wiring (mm 2 ) Weak Electric Signal 1-core shield wire 1 0.5 1-core shield wire 1 0.5 Type MCC-36HRN1 MCC-36HRN1-R MCC-48HRN1-R Power Phase 1-phase 3-phase 3-phase Frequency and Voltage 220-240V, 50Hz 380-415V, 50Hz 380-415V, 50Hz Circuit Breaker/ Fuse (A) 40/25 25/15 25/15 Indoor Unit Power Wiring (mm 2 ) 3 4.0 5 2.5 5 2.5 4.0 4.0 2.5 2.5 Outdoor Unit Power Indoor/Outdoor Connecting Wiring Wiring 3 4.0 5 2.5 5 2.5 (mm 2 ) Strong Electric Signal 3 2.5 3 1.0 3 1.0 Weak Electric Signal 1-core shield wire 1 0.5 Indoor Units 51

Field Wiring 13. Field Wiring MCAC-UTSM-2008-11 52 Indoor Units

MCAC-UTSM-2008-11 Ceiling & Floor Type Ceiling & Floor Type 1. Features... 54 2. Specifications... 55 3. Dimensions... 59 4. Service Space... 60 5. Wiring Diagrams... 61 6. Air Velocity and Temperature Distributions... 65 7. Capacity Tables... 67 8. Electric Characteristics... 76 9. Sound Levels... 76 10. Exploded View... 77 11. Accessories... 84 12. The Specification of Power... 84 13. Field Wiring... 85 Indoor Units 53

Features MCAC-UTSM-2008-11 1. Features 1.1. New design, more modern and elegant appearance. 1.2. Convenient installation --The ceiling type can be easily installed into a corner of the ceiling even if the ceiling is very narrow --It is especially useful when installation of an air conditioner in the center of the ceiling is impossible due to a structure such as one lighting 1.3. Two direction auto swing (vertical & horizontal) and wide angle air flow --Air flow directional control minimizes the air resistance and produces wilder air flow to vertical direction. --The range of horizontal air discharge is widened which secures wider air flow distribution to provide more comfortable air circulation no matter where the unit is set up 1.4. Three level fan speed, more humanism design, meets different air-supply requirement. 1.5. Water proof by utilizing the absorbing plastic film on water collector. 1.6. Easy operation. Auto-restart function, remote control and optional wire control method. 1.7. Low noise level plus compact size --Shape of the blades has been improved to prevent noise caused by turbulence. 54 Indoor Units

MCAC-UTSM-2008-11 Specifications 2. Specifications Model MUB-12HRN1 MUB-18HRN1 Code 220042101900 220042101920 Power supply V-ph-Hz 220~240-1-50 220~240-1-50 Cooling Heating Indoor fan motor Capacity kw 3.2 5.3 Input W 1200 1900 Capacity kw 4 6 Input W 1130 1850 Model YSK25-6L YSK55-4L Brand Welling Welling Input W 33.4/31.1/29.5 125/105/85 Capacitor uf 1.2uF/450V 2.5uF/450V Indoor coil Speed(Hi/Mi/Lo) r/min 756/666/592 1310/1190/1040 Number of rows 2 3 Tube pitch(a) row pitch(b) mm 25.4 22 25.4 22 Fin spacing mm 1.8 1.8 Fin type (code) Hydrophilic aluminum Hydrophilic aluminium Tube outside dia.and type mm φ9.53 Inner grooved copper tube φ9.53 Inner grooved copper Coil length height width mm 804 254 44 828 254 66 Number of circuits 3 3 Indoor air flow(hi/mi/lo) m 3 /h 600/480/400 878/792/700 Indoor noise level (sound pressure) db(a) 43/41/38 43/41/38 Indoor unit Dimension (W H D) mm 990 660 203 990 660 203 Packing (W H D) mm 1089 744 296 1089 744 296 Net/Gross weight kg 27/33 27/33 Refrigerant type R410A R410A Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/gas side mm φ6.4/φ12.7 φ6.4/φ12.7 Drainage water pipe diameter mm ODφ25 ODφ25 Connection wiring Power wiring mm 2 3 2.5 3 2.5 Strong electric signal wiring tube mm 2 5 2.5 5 2.5 Weak electric signal wiring mm 2 1-core shield wire 1 0.5 1-core shield wire 1 0.5 Controller R05/BGE(standard) R05/BGE(standard) Operation temperature 17-30 17-30 Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27 CDB, 19 CWB; Outdoor temp: 35 CDB; 2. Nominal heating capacities are based on the following conditions: Indoor temp: 20 CDB; Outdoor temp: 7 CDB, 6 CWB; 3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room. Indoor Units 55

Specifications MCAC-UTSM-2008-11 Model MUB-24HRN1 MUB-30HRN1 Code 220042101940 220044300050 Power supply V-ph-Hz 220~240-1-50 220~240-1-50 Cooling Heating Indoor fan motor Capacity kw 7.1 9 Input W 2700 3750 Capacity kw 7.6 9.5 Input W 2800 3500 Model YSK55-4L YSK80-4A Brand Welling Welling Input W 125/105/85 143/122/110 Capacitor uf 2.5uF/450V 3.5uF/450V Indoor coil Speed(Hi/Mi/Lo) r/min 1310/1190/1040 1310/1210/1115 Number of rows 3 3 Tube pitch(a) row pitch(b) mm 25.4 22 25.4 22 Fin spacing mm 1.8 1.8 Fin type (code) Hydrophilic aluminium Hydrophilic aluminum Tube outside dia.and type mm φ9.53 Inner grooved copper tube φ9.53 Inner grooved copper Coil length height width mm 828 254 66 1094 254 66 Number of circuits 3 5 Indoor air flow(hi/mi/lo) m 3 /h 1200/900/700 1400/1200/1000 Indoor noise level (sound pressure) db(a) 45/43/40 45/43/40 Indoor unit Dimension (W H D) mm 990 660 203 1280 660 203 Packing (W H D) mm 1089 744 296 1379 744 296 Net/Gross weight kg 27/33 35/40 Refrigerant type R410A R410A Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/gas side mm φ9.5/φ15.9 φ12.7/φ19 Drainage water pipe diameter mm ODφ25 ODφ25 Connection wiring Power wiring mm 2 3 2.5 3 2.5 Strong electric signal wiring tube mm 2 3 2.5 3 2.5 Weak electric signal wiring mm 2 1-core shield wire 1 0.5 1-core shield wire 1 0.5 Controller R05/BGE(standard) R05/BGE(standard) Operation temperature 17-30 17-30 Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27 CDB, 19 CWB; Outdoor temp: 35 CDB; 2. Nominal heating capacities are based on the following conditions: Indoor temp: 20 CDB; Outdoor temp: 7 CDB, 6 CWB; 3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room. 56 Indoor Units

MCAC-UTSM-2008-11 Specifications Model MUB-30HRN1 MUB-36HRN1 Code 220042102000 220044400160 Power supply V-ph-Hz 380~415-3-50 220~240-1-50 Cooling Heating Capacity kw 9 10.5 Input W 3750 3750 Capacity kw 9.5 12 Input W 3500 3500 Model YSK80-4A YSK80-4A Brand Welling Welling Indoor fan motor Indoor coil Input W 143/122/110 143/122/110 Capacitor uf 3.5uF/450V 3.5uF/450V Speed(Hi/Mi/Lo) r/min 1310/1210/1115 1310/1210/1115 Number of rows 3 3 Tube pitch(a) row pitch(b) mm 25.4 22 25.4 22 Fin spacing mm 1.8 1.8 Fin type (code) Hydrophilic aluminum Hydrophilic aluminum Tube outside dia.and type mm φ9.53 Inner grooved copper φ9.53 Inner grooved copper tube tube Coil length height width mm 1094 254 66 1094 254 66 Number of circuits 5 5 Indoor air flow(hi/mi/lo) m 3 /h 1400/1200/1000 1400/1200/1000 Indoor noise level (sound pressure) db(a) 45/43/40 45/43/40 Indoor unit Dimension (W H D) mm 1280 660 203 1280 660 203 Packing (W H D) mm 1379 744 296 1379 744 296 Net/Gross weight kg 35/40 35/40 Refrigerant type R410A R410A Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/gas side mm φ12.7/φ19 φ12.7/φ19 Drainage water pipe diameter mm ODφ25 ODφ25 Connection wiring Power wiring mm 2 5 2.5 3 2.5 Strong electric signal wiring mm 2 3 2.5 3 2.5 Weak electric signal wiring mm 2 1-core shield wire 1 0.5 Controller R05/BGE(standard) R05/BGE(standard) Operation temperature 17-30 17-30 Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27 CDB, 19 CWB; Outdoor temp: 35 CDB; 2. Nominal heating capacities are based on the following conditions: Indoor temp: 20 CDB; Outdoor temp: 7 CDB, 6 CWB; 3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room. Indoor Units 57

Specifications MCAC-UTSM-2008-11 Model MUB-36HRN1 MUB-48HRN1-R MUB-60HRN1-R Code 220042102020 220042102040 220042102060 Power supply V-ph-Hz 380~415-3-50 380~415-3-50 380~415-3-50 Cooling Heating Capacity kw 10.5 14 16 Input W 3750 4700 5578 Capacity kw 12 15 19 Input W 3700 4731 5764 Model YSK80-4A YSK59-4D( 2) YSK59-4D( 2) Indoor fan motor Indoor coil Brand Welling Welling Welling Input W 143/122/110 89.5/81.5/77.5 89.5/81.5/77.5 Capacitor uf 3.5uF/450V 2.5uF/450V 2.5uF/450V Speed(Hi/Mi/Lo) r/min 1310/1210/1115 1170/1070/995 1170/1070/995 Number of rows 3 3 3 Tube pitch(a) row pitch(b) mm 25.4 22 25.4 22 25.4 22 Fin spacing mm 1.8 1.8 1.8 Fin type (code) Hydrophilic aluminum Hydrophilic aluminium Hydrophilic aluminium Tube outside dia.and φ9.53 Inner grooved φ9.53 Inner grooved φ9.53 Inner grooved mm type copper tube copper tube copper tube Coil length height width mm 1094 254 66 1384 254 66 1384 254 66 Number of circuits 5 5 5 Indoor air flow(hi/mi/lo) m 3 /h 1400/1200/1000 2136/1985/1775 2343/2085/1736 Indoor noise level (sound pressure) db(a) 45/43/40 47/45/42 49/47/44 Indoor unit Dimension (W H D) mm 1280 660 203 1670 680 240 1670 680 240 Packing (W H D) mm 1379 744 296 1764 760 329 1764 760 329 Net/Gross weight kg 35/40 52/59 52/59 Refrigerant type R410A R410A R410A Design pressure MPa 4.4/2.6 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/gas side mm φ12.7/φ19 φ12.7/φ19 φ12.7/φ19 Drainage water pipe diameter mm ODφ25 ODφ25 ODφ25 Connection wiring Power wiring mm 2 5 2.5 5 2.5 5 2.5 Strong electric signal wiring Weak electric signal wiring mm 2 3 2.5 3 2.5 3 2.5 mm 2 Controller R05/BGE(standard) R05/BGE(standard) R05/BGE(standard) Operation temperature 17-30 17-30 17-30 Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27 CDB, 19 CWB; Outdoor temp: 35 CDB; 2. Nominal heating capacities are based on the following conditions: Indoor temp: 20 CDB; Outdoor temp: 7 CDB, 6 CWB; 3. Actual noise level may differ, depending on the room structure, etc, since these noise values are from an anechoic room. 58 Indoor Units

MCAC-UTSM-2008-11 Dimensions 3. Dimensions a. Wall mounting installation b. Ceiling installation Capacity (Btu/h) A B C D E F G 12000-24000 990 660 203 505 506 907 200 30000-36000 1280 660 203 795 506 1195 200 48000-60000 1670 680 240 1070 450 1542 200 Note: The dimension of 12000Btu/h, 18000Btu/h and 24000Btu/h are the same. The dimension of 30000Btu/h and 36000Btu/h are the same. The dimension of 48000Btu/h and 60000Btu/h are the same. Indoor Units 59

Service Space MCAC-UTSM-2008-11 4. Service Space 60 Indoor Units

MCAC-UTSM-2008-11 Wiring Diagrams 5. Wiring Diagrams 5.1 MUB-12HRN1 MUB-18HRN1 Indoor Units 61

Wiring Diagrams MCAC-UTSM-2008-11 5.2 MUB-24HRN1 MUB-30HRN1(1 phase) MUB-36HRN1(1 phase) 62 Indoor Units

MCAC-UTSM-2008-11 Wiring Diagrams 5.3 MUB-30HRN1(3 phase) MUB-36HRN1(3 phase) Indoor Units 63

Wiring Diagrams MCAC-UTSM-2008-11 5.3 MUB-48HRN1-R MUB-60HRN1-R 64 Indoor Units

MCAC-UTSM-2008-11 Air Velocity and Temperature Distributions 6. Air Velocity and Temperature Distributions Discharge angle 60 (CEILING) Airflow velocity Temperature Indoor Units 65

Air Velocity and Temperature Distributions MCAC-UTSM-2008-11 Discharge angle 60 (FLOOR) Temperature Airflow velocity 66 Indoor Units

MCAC-UTSM-2008-11 Capacity Tables 7. Capacity Tables MUB-12HRN1 Cooling Heating Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC 21/15ºC DB/WB 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB Heating TC 3.30 3.14 2.98 2.85 SC 2.44 2.41 2.38 2.39 Input 1.00 1.08 1.13 1.16 TC 3.39 3.23 3.07 2.88 SC 2.54 2.52 2.49 2.42 Input 1.06 1.13 1.18 1.24 TC 3.46 3.30 3.20 2.98 SC 2.56 2.54 2.50 2.44 Input 1.08 1.14 1.20 1.26 TC 3.52 3.39 3.33 3.07 SC 2.99 2.95 2.93 2.86 Input 1.13 1.18 1.26 1.31 Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB 15ºC 20ºC 27ºC Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw TC 5.20 4.20 3.44 3.12 Input 1.22 1.05 0.90 0.85 TC 5.04 4.00 3.24 3.04 Input 1.33 1.13 0.99 0.92 TC 4.72 3.76 3.04 2.96 Input 1.41 1.22 1.07 0.99 Indoor Units 67

Capacity Tables MCAC-UTSM-2008-11 MUB-18HRN1 Cooling Heating Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC 21/15ºC DB/WB 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB Heating TC 5.46 5.19 4.93 4.72 SC 4.04 4.00 3.94 3.96 Input 1.58 1.71 1.79 1.84 TC 5.62 5.35 5.09 4.77 SC 4.21 4.18 4.12 4.01 Input 1.67 1.79 1.86 1.96 TC 5.72 5.46 5.30 4.93 SC 4.24 4.20 4.13 4.04 Input 1.71 1.81 1.90 2.00 TC 5.83 5.62 5.51 5.09 SC 4.96 4.89 4.85 4.73 Input 1.79 1.86 2.00 2.07 Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB 15ºC 20ºC 27ºC Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw TC 7.80 6.30 5.16 4.68 Input 2.00 1.72 1.48 1.39 TC 7.56 6.00 4.86 4.56 Input 2.18 1.85 1.63 1.50 TC 7.08 5.64 4.56 4.44 Input 2.31 2.00 1.76 1.63 68 Indoor Units

MCAC-UTSM-2008-11 Capacity Tables MUB-24HRN1 Cooling Heating Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC 21/15ºC DB/WB 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB Heating TC 7.31 6.96 6.60 6.32 SC 5.41 5.36 5.28 5.31 Input 2.24 2.43 2.54 2.62 TC 7.53 7.17 6.82 6.39 SC 5.64 5.59 5.52 5.37 Input 2.38 2.54 2.65 2.78 TC 7.67 7.31 7.10 6.60 SC 5.67 5.63 5.54 5.41 Input 2.43 2.57 2.70 2.84 TC 7.81 7.53 7.38 6.82 SC 6.64 6.55 6.50 6.34 Input 2.54 2.65 2.84 2.94 Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB 15ºC 20ºC 27ºC Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw TC 9.88 7.98 6.54 5.93 Input 3.02 2.60 2.24 2.10 TC 9.58 7.60 6.16 5.78 Input 3.30 2.80 2.46 2.27 TC 8.97 7.14 5.78 5.62 Input 3.50 3.02 2.66 2.46 Indoor Units 69

Capacity Tables MCAC-UTSM-2008-11 MUB-30HRN1 (1 phase) Cooling Heating Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC 21/15ºC DB/WB 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB Heating TC 9.27 8.82 8.37 8.01 SC 6.86 6.79 6.70 6.73 Input 3.11 3.38 3.53 3.64 TC 9.54 9.09 8.64 8.10 SC 7.16 7.09 7.00 6.80 Input 3.30 3.53 3.68 3.86 TC 9.72 9.27 9.00 8.37 SC 7.19 7.14 7.02 6.86 Input 3.38 3.56 3.75 3.94 TC 9.90 9.54 9.36 8.64 SC 8.42 8.30 8.24 8.04 Input 3.53 3.68 3.94 4.09 Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB 15ºC 20ºC 27ºC Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw TC 12.35 9.98 8.17 7.41 Input 3.78 3.26 2.80 2.63 TC 11.97 9.50 7.70 7.22 Input 4.13 3.50 3.08 2.84 TC 11.21 8.93 7.22 7.03 Input 4.38 3.78 3.33 3.08 70 Indoor Units

MCAC-UTSM-2008-11 Capacity Tables MUB-30HRN1 (3 phase) Cooling Heating Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC 21/15ºC DB/WB 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB Heating TC 9.27 8.82 8.37 8.01 SC 6.86 6.79 6.70 6.73 Input 3.11 3.38 3.53 3.64 TC 9.54 9.09 8.64 8.10 SC 7.16 7.09 7.00 6.80 Input 3.30 3.53 3.68 3.86 TC 9.72 9.27 9.00 8.37 SC 7.19 7.14 7.02 6.86 Input 3.38 3.56 3.75 3.94 TC 9.90 9.54 9.36 8.64 SC 8.42 8.30 8.24 8.04 Input 3.53 3.68 3.94 4.09 Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB 15ºC 20ºC 27ºC Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw TC 12.35 9.98 8.17 7.41 Input 3.78 3.26 2.80 2.63 TC 11.97 9.50 7.70 7.22 Input 4.13 3.50 3.08 2.84 TC 11.21 8.93 7.22 7.03 Input 4.38 3.78 3.33 3.08 Indoor Units 71

Capacity Tables MCAC-UTSM-2008-11 MUB-36HRN1 (1 phase) Cooling Heating Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC 21/15ºC DB/WB 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB Heating TC 10.82 10.29 9.77 9.35 SC 8.00 7.92 7.81 7.85 Input 3.11 3.38 3.53 3.64 TC 11.13 10.61 10.08 9.45 SC 8.35 8.27 8.16 7.94 Input 3.30 3.53 3.68 3.86 TC 11.34 10.82 10.50 9.77 SC 8.39 8.33 8.19 8.01 Input 3.38 3.56 3.75 3.94 TC 11.55 11.13 10.92 10.08 SC 9.82 9.68 9.61 9.37 Input 3.53 3.68 3.94 4.09 Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB 15ºC 20ºC 27ºC Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw TC 15.60 12.60 10.32 9.36 Input 3.78 3.26 2.80 2.63 TC 15.12 12.00 9.72 9.12 Input 4.13 3.50 3.08 2.84 TC 14.16 11.28 9.12 8.88 Input 4.38 3.78 3.33 3.08 72 Indoor Units

MCAC-UTSM-2008-11 Capacity Tables MUB-36HRN1 (3 phase) Cooling Heating Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC 21/15ºC DB/WB 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB Heating TC 10.82 10.29 9.77 9.35 SC 8.00 7.92 7.81 7.85 Input 3.11 3.38 3.53 3.64 TC 11.13 10.61 10.08 9.45 SC 8.35 8.27 8.16 7.94 Input 3.30 3.53 3.68 3.86 TC 11.34 10.82 10.50 9.77 SC 8.39 8.33 8.19 8.01 Input 3.38 3.56 3.75 3.94 TC 11.55 11.13 10.92 10.08 SC 9.82 9.68 9.61 9.37 Input 3.53 3.68 3.94 4.09 Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB 15ºC 20ºC 27ºC Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw TC 15.60 12.60 10.32 9.36 Input 4.00 3.44 2.96 2.78 TC 15.12 12.00 9.72 9.12 Input 4.37 3.70 3.26 3.00 TC 14.16 11.28 9.12 8.88 Input 4.63 4.00 3.52 3.26 Indoor Units 73

Capacity Tables MCAC-UTSM-2008-11 MUB-48HRN1-R Cooling Heating Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC 21/15ºC DB/WB 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB Heating TC 14.42 13.72 13.02 12.46 SC 10.67 10.56 10.42 10.47 Input 3.90 4.23 4.42 4.56 TC 14.84 14.14 13.44 12.60 SC 11.13 11.03 10.89 10.58 Input 4.14 4.42 4.61 4.84 TC 15.12 14.42 14.00 13.02 SC 11.19 11.10 10.92 10.68 Input 4.23 4.47 4.70 4.94 TC 15.40 14.84 14.56 13.44 SC 13.09 12.91 12.81 12.50 Input 4.42 4.61 4.94 5.12 Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB 15ºC 20ºC 27ºC Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw TC 19.50 15.75 12.90 11.70 Input 5.11 4.40 3.78 3.55 TC 18.90 15.00 12.15 11.40 Input 5.58 4.731 4.16 3.83 TC 17.70 14.10 11.40 11.10 Input 5.91 5.11 4.49 4.16 74 Indoor Units

MCAC-UTSM-2008-11 Capacity Tables MUB-60HRN1-R Cooling Heating Cooling Outdoor conditions (DB) Indoor Conditions (kw) 21ºC 28ºC 35ºC 43ºC 21/15ºC DB/WB 24/17ºC DB/WB 27/19ºC DB/WB 32/23ºC DB/WB Heating TC 16.48 15.68 14.88 14.24 SC 12.20 12.07 11.90 11.96 Input 4.63 5.02 5.24 5.41 TC 16.96 16.16 15.36 14.40 SC 12.72 12.60 12.44 12.10 Input 4.91 5.24 5.47 5.75 TC 17.28 16.48 16.00 14.88 SC 12.79 12.69 12.48 12.20 Input 5.02 5.30 5.578 5.86 TC 17.60 16.96 16.64 15.36 SC 14.96 14.76 14.64 14.28 Input 5.24 5.47 5.86 6.08 Outdoor conditions Indoor Conditions (DB) (kw) 24/18ºC DB/WB 7/6ºC DB/WB 2/1ºC DB/WB -5/-6ºC DB/WB 15ºC 20ºC 27ºC Remark: TC : Total capacity ; kw SC: Sensible heat capacity ; kw Input: Input power ; kw TC 24.70 19.95 16.34 14.82 Input 6.23 5.36 4.61 4.32 TC 23.94 19.00 15.39 14.44 Input 6.80 5.764 5.07 4.67 TC 22.42 17.86 14.44 14.06 Input 7.21 6.23 5.48 5.07 Indoor Units 75

Electric Characteristics MCAC-UTSM-2008-11 8. Electric Characteristics Model Indoor Units Power Supply Indoor Fan Motor Hz Voltage Min. Max. MCA MFA kw FLA MUB-12HRN1 50 220-240V 198V 254V 0.2 16 0.025 0.145 MUB-18HRN1 50 220-240V 198V 254V 0.71 16 0.055 0.57 MUB-24HRN1 50 220-240V 198V 254V 0.71 25 0.055 0.57 MUB-30HRN1 50 220-240V 198V 254V 0.79 25 0.08 0.63 MUB-30HRN1 50 380-415V 342V 418V 0.79 20 0.08 0.63 MUB-36HRN1 50 220-240V 198V 254V 0.79 25 0.08 0.63 MUB-36HRN1 50 380-415V 342V 418V 0.79 20 0.08 0.63 MUB-48HRN1-R 50 380-415V 342V 418V 1.25 20 0.059 0.39( 2) MUB-60HRN1-R 50 380-415V 342V 418V 1.25 20 0.059 0.39( 2) Remark: MCA: Min. Current Amps. (A) MFA: Max. Fuse Amps. (A) KW: Fan Motor Rated Output (kw) FLA: Full Load Amps. (A) 9. Sound Levels Ceiling Floor Model Noise level H M L MUB-12HRN1 43 41 38 MUB-18HRN1 43 41 38 MUB-24HRN1 45 43 40 MUB-30HRN1 (1 phase) 45 43 40 MUB-30HRN1 (3 phase) 45 43 40 MUB-36HRN1 (1 phase) 45 43 40 MUB-36HRN1 (3 phase) 45 43 40 MUB-48HRN1-R 47 45 42 MUB-60HRN1-R 49 47 44 76 Indoor Units

MCAC-UTSM-2008-11 Exploded View 10. Exploded View 10.1 MUB-12HRN1 No. Part Name Quantity No. Part Name Quantity 1 Filter 2 20 Evaporator ass'y 1 2 Grille clamp 2 21 Installation board 1 3 Grille 1 22 Foam ass'y 1 4 Grille clamp 2 23 Foam ass'y 1 5 Grille strengthening rib 1 24 Evaporator Left support 1 6 Volute shell 2 25 Foam ass'y 1 7 Grille lock 1 26 Support board 1 8 Plastic fan 2 27 Evaporator right clapboard 1 9 Motor clamp 1 28 Evaporator left clapboard 1 10 Motor clamp 1 29 Cover 1 11 Volute shell 2 30 Display panel box 1 12 Board 1 31 Display board ass'y 1 13 Middle beam 1 32 Manual button 1 14 E-part box cover 1 33 Air outlet ass'y 1 15 E-part box ass'y 1 34 Foam 1 15.1 Main controller ass'y 1 35 Drainage pan holder 1 15.2 Motor capacitor 1 36 Drainage pan ass'y 1 15.3 Wire joint 1 37 Plastic cover 2 15.4 Wire joint 1 38 Motor 1 15.5 Transformer 1 39 Panel ass'y 1 16 Left cover 1 40 Remote controller 1 17 Installation board 1 41 Installation bracket 1 18 Base ass'y 1 42 Room temp sensor ass'y 1 19 Rear cover 1 43 Temp.sensor ass'y 1 Indoor Units 77

Exploded View MCAC-UTSM-2008-11 10.2 MUB-18HRN1 No. Part Name Quantity No. Part Name Quantity 1 Filter 2 20 Evaporator ass'y 1 2 Grille clamp 2 21 Installation board 1 3 Grille 1 22 Foam ass'y 1 4 Grille hang 2 23 Foam ass'y 1 5 Grille strengthening rib 1 24 Evaporator Left support 1 6 Volute shell 2 25 Foam ass'y 1 7 Grille lock 1 26 Support board 1 8 Plastic fan 2 27 Evaporator right clapboard 1 9 Motor clamp 1 28 Evaporator left clapboard 1 10 Motor clamp 1 29 Cover 1 11 Volute shell 2 30 Display panel box 1 12 Board 1 31 Display board ass'y 1 13 Middle beam 1 32 Manual button 1 14 E-part box cover 1 33 Air outlet frame mount ass'y 1 15 E-part box ass'y 1 34 Foam 1 15.1 Main controller ass'y 1 35 Drainage pan holder 1 15.2 Motor capacitor 1 36 Drainage pan ass'y 1 15.3 Wire joint 1 37 Plastic cover 2 15.4 Wire joint 1 38 Motor 1 15.5 Transformer 1 39 Panel ass'y 1 16 Left cover 1 40 Remote controller 1 17 Installation board 1 41 Installation bracket 1 18 Base ass'y 1 42 Room temp. sensor ass'y 1 19 Rear cover 1 43 Evaporator temp. sensor ass'y 1 78 Indoor Units

MCAC-UTSM-2008-11 Exploded View 10.3 MUB-24HRN1 No. Part Name Quantity No. Part Name Quantity 1 Filter 2 20 Evaporator ass'y 1 2 Grille clamp 2 21 Installation board 1 3 Grille 1 22 Foam ass'y 1 4 Grille hang 2 23 Foam ass'y 1 5 Grille strengthening rib 1 24 Evaporator Left support 1 6 Volute shell 2 25 Foam ass'y 1 7 Grille lock 1 26 Support board 1 8 Plastic fan 2 27 Evaporator right clapboard 1 9 Motor clamp 1 28 Evaporator left clapboard 1 10 Motor clamp 1 29 Cover 1 11 Volute shell 2 30 Display panel box 1 12 Board 1 31 Display board ass'y 1 13 Middle beam 1 32 Manual button 1 14 E-part box cover 1 33 Air outlet frame mount ass'y 1 15 E-part box ass'y 1 34 Foam 1 15.1 Main controller ass'y 1 35 Drainage pan holder 1 15.2 Motor capacitor 1 36 Drainage pan ass'y 1 15.3 Wire joint 1 37 Plastic cover 2 15.4 Wire joint 1 38 Motor 1 15.5 Transformer 1 39 Panel ass'y 1 16 Left cover 1 40 Remote controller 1 17 Installation board 1 41 Installation bracket 1 18 Base ass'y 1 42 Room temp. sensor ass'y 1 19 Rear cover 1 43 Evaporator temp. sensor ass'y 1 Indoor Units 79

Exploded View MCAC-UTSM-2008-11 10.4 MUB-30HRN1 MUB-36HRN1(1 phase) No. Part Name Quantity No. Part Name Quantity 1 Filter 3 20 Evaporator ass'y 1 2 Grille clamp 2 21 Installation board 1 3 Grille 1 22 Foam ass'y 1 4 Grille clamp 2 23 Foam ass'y 1 5 Grille strengthening rib 1 24 Evaporator Left support 1 6 Volute shell 3 25 Foam ass'y 1 7 Grille lock 2 26 Support board 1 8 Plastic fan 3 27 Evaporator right clapboard 1 9 Motor clamp 1 28 Evaporator left clapboard 1 10 Motor clamp 1 29 Cover 1 11 Volute shell 3 30 Display panel box 1 12 Board 1 31 Display board ass'y 1 13 Middle beam 1 32 Manual button 1 14 E-part box cover 1 33 Air outlet ass'y 1 15 E-part box ass'y 1 34 Foam 1 15.1 Main controller ass'y 1 35 Drainage pan holder 1 15.2 Motor capacitor 1 36 Drainage pan ass'y 1 15.3 Wire joint 1 37 Plastic cover 1 15.4 Wire joint 1 38 Motor 1 15.5 Transformer 1 39 Panel ass'y 1 16 Left cover 1 40 Remote controller 1 17 Installation board 1 41 Installation bracket 1 18 Base ass'y 1 42 Room temp sensor ass'y 1 19 Rear cover 1 43 Temp.sensor ass'y 1 80 Indoor Units

MCAC-UTSM-2008-11 Exploded View 10.5 MUB-30HRN1 MUB-36HRN1(3 phase) No. Part Name Quantity No. Part Name Quantity 1 Filter 3 20 Evaporator ass'y 1 2 Grille clamp 2 21 Installation board 1 3 Grille 1 22 Foam ass'y 1 4 Grille clamp 2 23 Foam ass'y 1 5 Grille strengthening rib 1 24 Evaporator Left support 1 6 Volute shell 3 25 Foam ass'y 1 7 Grille lock 2 26 Support board 1 8 Plastic fan 3 27 Evaporator right clapboard 1 9 Motor clamp 1 28 Evaporator left clapboard 1 10 Motor clamp 1 29 Cover 1 11 Volute shell 3 30 Display panel box 1 12 Board 1 31 Display board ass'y 1 13 Middle beam 1 32 Manual button 1 14 E-part box cover 1 33 Air outlet ass'y 1 15 E-part box ass'y 1 34 Foam 1 15.1 Main controller ass'y 1 35 Drainage pan holder 1 15.2 Motor capacitor 1 36 Drainage pan ass'y 1 15.3 Wire joint 1 37 Plastic cover 1 15.4 Wire joint 1 38 Motor 1 15.5 Transformer 1 39 Panel ass'y 1 16 Left cover 1 40 Remote controller 1 17 Installation board 1 41 Installation bracket 1 18 Base ass'y 1 42 Room temp sensor ass'y 1 19 Rear cover 1 43 Temp.sensor ass'y 1 Indoor Units 81

Exploded View MCAC-UTSM-2008-11 10.6 MUB-48HRN1-R 31.1 No. Part Name Quantity No. Part Name Quantity 1 Grille ass'y 2 21 Volute shell 4 2 Motor clamp 2 22 Middle beam 1 3 Motor clamp 2 23 E-part box cover 1 4 Filter bracket 2 24 E-part box ass'y 1 5 Installation board 1 24.1 Main controller ass'y 1 6 Installation board 1 24.2 Motor capacitor 2 7 Filter bracket 2 24.3 Wire joint 1 8 Right sealed board 1 24.4 Wire joint 1 9 left sealed board 1 24.5 Transformer 1 10 Pipe clamp board 1 25 Foam 2 11 Cover 1 26 Top cover ass'y 1 12 Left cover 1 27 Drainage pan ass'y 1 13 Display board ass'y 1 28 Plastic cover 1 14 Display installation box 1 29 Foam 2 15 Air outlet ass'y 1 30 Filter 4 15.1 Display board ass'y 1 31 Evaporator ass'y 1 16 Base ass'y 1 31.1 Temp. sensor ass'y 1 17 Plastic fan 4 32 Remote controller 1 18 Volute shell 4 33 Installation bracket 1 19 Motor 2 34 Room temp. sensor ass'y 1 20 Motor bracket 2 82 Indoor Units

MCAC-UTSM-2008-11 Exploded View 10.7 MUB-60HRN1-R No. Part Name Quantity No. Part Name Quantity 1 Grille ass'y 2 21 Volute shell 4 2 Motor clamp 2 22 Middle beam 1 3 Motor clamp 2 23 E-part box cover 1 4 Filter bracket 2 24 E-part box ass'y 1 5 Installation board 1 24.1 Main controller ass'y 1 6 Installation board 1 24.2 Motor capacitor 2 7 Filter bracket 2 24.3 Wire joint 1 8 Right sealed board 1 24.4 Wire joint 1 9 Left sealed board 1 24.5 Transformer 1 10 Pipe clamp board 1 25 Foam 2 11 Cover 1 26 Top cover ass'y 1 12 Left cover 1 27 Drainage pan ass'y 1 13 Display board ass'y 1 28 Plastic cover 1 14 Display installation box 1 29 Foam 2 15 Air outlet frame ass'y 1 30 Filter 4 15.1 Display board ass'y 1 31 Evaporator ass'y 1 16 Base ass'y 1 31.1 Temp. sensor ass'y 1 17 Plastic fan 4 32 Remote controller 1 18 Volute shell 4 33 Installation bracket 1 19 Motor 2 34 Room temp. sensor ass'y 1 20 Motor bracket 2 Indoor Units 83

Accessories MCAC-UTSM-2008-11 11. Accessories Name Shape Quantity Installation fittings 1.Hook 2 2.Hanging arm 2 3. Remote controller 1 Remote controller & Its Holder 4. Remote controller holder 1 5. Mounting screw(st2.9 10-C-H) 2 6. Alkaline dry batteries (AM4) 2 Others 7. Owner's manual 1 8. Installation manual 1 9. Remote controller manual 1 12. The Specification of Power Power Type 12000-18000Btu/h 24000-36000Btu/ h 30000-60000Btu/ h Phase 1-phase 1-phase 3-phase Frequency and Voltage 220-240V, 50Hz 220-240V, 50Hz 380-415V, 50Hz Circuit Breaker/ Fuse (A) 20/16 40/25 40/20 Indoor Unit Power Wiring (mm 2 ) 3 2.5 3 2.5 5 2.5 Indoor/Outdoor Connecting Wiring (mm 2 ) Ground Wiring 2.5 2.5 2.5 Outdoor Unit Power Wiring 3 2.5 5 2.5 Strong Electric Signal 5 2.5 3 2.5 3 2.5 1-core shield wire 1-core shield wire Weak Electric Signal 1 0.5 mm 2 1 0.5 mm 2 84 Indoor Units

MCAC-UTSM-2008-11 Field Wiring 13. Field Wiring MUB-12HRN1 MUB-18HRN1 Indoor Units 85

Field Wiring MCAC-UTSM-2008-11 MUB-24HRN1 MUB-30HRN1 MUB-36HRN1(1 phase) 86 Indoor Units

MCAC-UTSM-2008-11 Field Wiring MUB-30HRN1 MUB-36HRN1(3 phase) MUB-48HRN1-R MUB-60HRN1-R Indoor Units 87

Outdoor Units MCAC-UTSM-2008-11 Part 3 Outdoor Units 1. Specifications... 89 2. Dimensions... 94 3. Service Space... 99 4. Piping Diagrams... 100 5. Wiring Diagrams... 103 6. Electric Characteristics... 109 7. Operation Limits... 109 8. Sound Levels... 110 9. Exploded View...111 10. Troubleshooting... 118 88 Outdoor Units

MCAC-UTSM-2008-11 Specifications 1. Specifications Model MOU-12HN1 MOUA-18HN1 Code 220075100110 220075200490 Power supply V-ph-Hz 220~240-1-50 220~240-1-50 Max. input consumption W 1500 2400 Max. input current A 7.0 10.9 Starting current A 26 53 Compressor Outdoor fan motor Outdoor coil Model PA140X2C-4FT PA225X2CS-4KU1 Type ROTARY ROTARY Brand MIDEA-TOSHIBA MIDEA-TOSHIBA Supplier MIDEA-TOSHIBA MIDEA-TOSHIBA Capacity Btu/h 11567 18697 Input W 1150 1855 Rated current(rla) A 5.3 8.7 Locked rotor Amp(LRA) A 29.9 36.8 Thermal protector Internal Internal Capacitor μf 35μF/440-450V 50μF/440V-450V Refrigerant oil ml ESTEL OIL VG74, 480 ESTER OIL VG74, 750 Model YDK24-6F YDK48-6H(A) Type AC motor AC motor Brand Welling Welling Input W 58 110 Capacitor μf 2.5uF/450V 3μF/450V Speed r/min 800 890 Number of rows 2 2 Tube pitch(a) row pitch(b) mm 21 13.37 22 19.05 Fin spacing mm 1.5 1.4 Fin type Hydrophilic aluminium Hydrophilic aluminium Tube outside dia.and type mm φ7 Inner grooved copper φ7.94 Inner grooved copper tube tube Coil length height mm 651 559 26.74 645 528 38.1 width Number of circuits 2 5 Outdoor air flow m 3 /h 2100 2439 Outdoor noise level (sound pressure) db(a) 43 48 Outdoor unit Refrigerant Dimension(W H D) mm 838(780) 547 250 824(762) 593 282 Packing (W H D) mm 910 575 335 891 657 359 Net/Gross weight kg 37/39 41/44 Type R410A R410A Charged volume g 1120 1450 Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/ Gas side mm φ6.4/φ12.7 φ6.4/φ12.7 Max. pipe length m 25 25 Max. difference in level m 15 15 Ambient temp. cooling:18~43; heating:-7~24 cooling: 18~43; heating:-7~24 Outdoor Units 89

Specifications MCAC-UTSM-2008-11 Model MOUA-24HN1 MOU-30HN1 Code 220075300570 220075400010 Power supply V-ph-Hz 220~240-1-50 220~240-1-50 Max. input consumption W 3300 4620 Max. input current A 15 21 Starting current A 62 97 Compressor Outdoor fan motor Outdoor coil Model PA290X3CS-4MU1 C-SBN301H5D Type ROTARY SCROLL Brand MIDEA-TOSHIBA SANYO Supplier MIDEA-TOSHIBA SANYO Capacity Btu/h 24600 33438 Input W 2430 3650 Rated current(rla) A 11.4 17.65 Locked rotor Amp(LRA) A 61 97 Thermal protector Internal Internal Capacitor μf 50μF/440V-450V 60uF/450V Refrigerant oil ml ESTER OIL VG74, 950 FV68S, 1700 Model YDK53-6Q YDK250-6D Type AC motor AC motor Brand Welling Welling Input W 144 304 Capacitor μf 3μF/450V 10uF±5% 450V Speed r/min 840 740 Number of rows 2 1.6 Tube pitch(a) row pitch(b) mm 22 19.05 22 19.05 Fin spacing mm 1.4 1.6 Fin type Hydrophilic aluminium Hydrophilic aluminium Tube outside dia.and type mm φ7.94 Inner grooved copper φ7.94 Inner grooved copper tube tube Coil length height mm 820 616 38.1 width 727 902 38.1 Number of circuits 6 7 Outdoor air flow m 3 /h 3200 5000 Outdoor noise level (sound pressure) db(a) 55 57 Outdoor unit Refrigerant Dimension(W H D) mm 932(852) 660 340 1075(990) 966 354 Packing (W H D) mm 986 726 436 1120 1100 435 Net/Gross weight kg 56/61 94/104 Type R410A R410A Charged volume g 2050 3100 Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/ Gas side mm φ9.5/φ15.9 φ12.7/φ19 Max. pipe length m 30 30 Max. difference in level m 15 20 Ambient temp. cooling: 18~43; heating:-7~24 cooling: 18~43; heating:-7~24 90 Outdoor Units

MCAC-UTSM-2008-11 Specifications Model MOU-30HN1-R MOU-36HN1 Code 220075400020 220075500670 Power supply V-ph-Hz 380~415-3-50 220~240-1-50 Max. input consumption W 4620 4620 Max. input current A 7.1 21 Starting current A 61 97 Compressor Outdoor fan motor Outdoor coil Model C-SBN303H8D C-SBN301H5D Type SCROLL SCROLL Brand SANYO SANYO Supplier SANYO(Dalian) SANYO Capacity Btu/h 33438 33438 Input W 3650 3650 Rated current(rla) A 6.58 17.65 Locked rotor Amp(LRA) A 61 97 Thermal protector Internal Internal Capacitor μf / 60uF/450V Refrigerant oil ml DAPHNE FV68S, 1700 FV68S 1700 Model YDK250-6D YDK250-6D Type AC motor AC motor Brand Welling Welling Input W 304 304 Capacitor μf 10uF±5% 450V 10uF±5% 450V Speed r/min 740 740 Number of rows 1.6 1.6 Tube pitch(a) row pitch(b) mm 22 19.05 22 19.05 Fin spacing mm 1.6 1.6 Fin type Hydrophilic aluminium Hydrophilic aluminium Tube outside dia.and type mm φ7.94 Inner grooved copper φ7.94 Inner grooved copper tube tube Coil length height mm width 727 902 38.1 727 902 38.1 Number of circuits 7 7 Outdoor air flow m 3 /h 5000 5000 Outdoor noise level (sound pressure) db(a) 57 57 Outdoor unit Refrigerant Dimension(W H D) mm 1075(990) 966 354 1075(990) 966 354 Packing (W H D) mm 1120 1100 435 1120 1100 435 Net/Gross weight kg 99/104 99/104 Type R410A R410A Charged volume g 3100 3100 Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/ Gas side mm φ12.7/φ19 φ12.7/φ19 Max. pipe length m 30 30 Max. difference in level m 20 20 Ambient temp. cooling: 18~43; heating:-7~24 cooling: 18~43; heating:-7~24 Outdoor Units 91

Specifications MCAC-UTSM-2008-11 Model MOU-36HN1-R MOUA-48HN1-R Code 220075500680 220075700040 Power supply V-ph-Hz 380~415-3-50 380~415-3-50 Max. input consumption W 4620 5870 Max. input current A 8 10.7 Starting current A 61 42 Compressor Outdoor fan motor Outdoor coil Model C-SBN303H8D JT160G-P8Y1 Type SCROLL SCROLL Brand SANYO DAIKIN Supplier SANYO(Dalian) DAIKIN Capacity Btu/h 33438 49098.7 Input W 3650 4880 Rated current(rla) A 6.58 8.3 Locked rotor Amp(LRA) A 61 63 Thermal protector Internal Internal Capacitor μf / / Refrigerant oil ml DAPHNE FV68S, 1700 DAPHNE FVC68D, 1500 Model YDK250-6D YDK65-6-1+YDK65-6F-1 Type AC motor AC motor Brand Welling Welling Input W 304 153+153 Capacitor μf 10uF±5% 450V 4μF/450V 2 Speed r/min 740 825 Number of rows 1.6 2 Tube pitch(a) row pitch(b) mm 22 19.05 22 19.05 Fin spacing mm 1.6 1.6 Fin type Hydrophilic aluminium Hydrophilic aluminium Tube outside dia.and type mm φ7.94 Inner grooved copper φ7.94 Inner grooved copper tube tube Coil length height mm width 727 902 38.1 845 1100 38.1 Number of circuits 7 8 Outdoor air flow m 3 /h 5000 6800 Outdoor noise level (sound pressure) db(a) 57 59 Outdoor unit Refrigerant Dimension(W H D) mm 1075(990) 966 354 986(900) 1167 340 Packing (W H D) mm 1120 1100 435 1032 1307 443 Net/Gross weight kg 99/104 93/99 Type R410A R410A Charged volume g 3100 3150 Design pressure MPa 4.4/2.6 4.4/2.6 Refrigerant piping Liquid side/ Gas side mm φ12.7/φ19 φ12.7/φ19 Max. pipe length m 30 30 Max. difference in level m 20 20 Ambient temp. cooling: 18~43; heating:-7~24 cooling: 18~43; heating:-7~24 92 Outdoor Units

MCAC-UTSM-2008-11 Specifications Model MOUA-60HN1-R Code 220075800650 Power supply V-ph-Hz 380~415-3-50 Max. input consumption W 7500 Max. input current A 12.8 Starting current A 52 Model C-SBN453H8D Type SCROLL Brand SANYO Supplier Dalian SANYO Compressor Co., Ltd. Capacity Btu/h 55956.8 Compressor Input W 5750 Rated current(rla) A 9.77 Locked rotor Amp(LRA) A 67 Thermal protector Internal Capacitor μf / Refrigerant oil ml FV68S, 1700 Model YDK65-6-1+YDK65-6F-1 Type AC motor Outdoor fan motor Brand Welling Input W 153+153 Capacitor μf 4μF/450V Speed r/min 825 Number of rows 2 Tube pitch(a) row pitch(b) mm 22 19.05 Fin spacing mm 1.6 Outdoor coil Fin type Hydrophilic aluminium Tube outside dia.and type mm φ7.94 Inner grooved copper tube Coil length height width mm 845 1100 38.1 Number of circuits 8 Outdoor air flow m 3 /h 6850 Outdoor noise level (sound pressure) db(a) 59.3 Dimension(W H D) mm 986(900) 1167 340 Outdoor unit Packing (W H D) mm 1032 1307 443 Net/Gross weight kg 93/99 Refrigerant Type R410A Charged volume g 3200 Design pressure MPa 4.4/2.6 Liquid side/ Gas side mm φ12.7/φ19 Refrigerant piping Max. pipe length m 30 Max. difference in level m 20 Ambient temp. cooling: 18~43; heating:-7~24 Outdoor Units 93

Dimensions MCAC-UTSM-2008-11 2. Dimensions 2.1 MOU-12HN1 94 Outdoor Units

MCAC-UTSM-2008-11 Dimensions 2.2 MOUA-18HN1 Outdoor Units 95

Dimensions MCAC-UTSM-2008-11 2.3 MOUA-24HN1 96 Outdoor Units

MCAC-UTSM-2008-11 Dimensions 2.4 MOU-30HN1 MOU-30HN1-R MOU-36HN1 MOU-36HN1-R Outdoor Units 97

Dimensions MCAC-UTSM-2008-11 2.5 MOUA-48HN1-R MOUA-60HN1-R 98 Outdoor Units

>200cm >60cm MCAC-UTSM-2008-11 Service Space 3. Service Space (Wall or obstacle) Obstacle >30cm Air inlet >30cm Air inlet Maintain channel >60cm Fix with bolt Air outlet Necessary width Deep foundation 600mm is necessary between 2 outdoor units Outdoor Units 99

Piping Diagrams MCAC-UTSM-2008-11 4. Piping Diagrams 4.1 MOU-12HN1 Outdoor unit Indoor units condenser temp. sensor 4-way valve T3 Check valve filter Throttle capiliary stop valve T2 evaporator temp. sensor T1 room temp. sensor stop valve compressor 4.2 MOUA-18HN1 Outdoor unit Indoor units condenser temp. sensor 4-way valve T3 filter Throttle capiliary stop valve T2 evaporator temp. sensor T1 room temp. sensor stop valve compressor 100 Outdoor Units

MCAC-UTSM-2008-11 Piping Diagrams 4.3 MOUA-24HN1 Outdoor unit Indoor units condenser temp. sensor 4-way valve T3 filter Throttle capiliary stop valve T2 evaporator temp. sensor T1 room temp. sensor stop valve compressor 4.4 MOU-30HN1 MOU-36HN1 MOU-30HN1-R MOU-36HN1-R Outdoor unit Indoor units condenser temp. sensor Muffle 4-way valve T3 T4 ambient temp. sensor Check valve filter Throttle capiliary stop valve T2 evaporator temp. sensor T1 room temp. sensor T5 Discharge temp. sensor High pressure switch stop valve compressor low-pressure accumulator Remark: For MOU-30HN1, MOU-36HN1, the T4 ambient temp. sensor is not included. Outdoor Units 101

Piping Diagrams MCAC-UTSM-2008-11 4.5 MOUA-48HN1-R Outdoor unit Indoor units condenser temp. sensor 4-way valve T3 filter T2 evaporator temp. sensor High pressure switch T4 ambient temp. sensor Throttle capiliary stop valve T1 room temp. sensor stop valve Discharge temp.sensor Low pressure switch compressor low pressure receiver 4.6 MOUA-60HN1-R Outdoor unit Indoor units condenser temp. sensor 4-way valve high pressure switch T3 T4 ambient temp. sensor filter Throttle capiliary stop valve T2 evaporator temp. sensor T1 room temp. sensor muffle discharge temp.sensor low pressure switch stop valve compressor low pressure receiver 102 Outdoor Units

MCAC-UTSM-2008-11 Wiring Diagrams 5. Wiring Diagrams 5.1 MOU-12HN1 Outdoor Units 103

Wiring Diagrams MCAC-UTSM-2008-11 5.2 MOUA-18HN1 104 Outdoor Units

MCAC-UTSM-2008-11 Wiring Diagrams 5.3 MOUA-24HN1 Outdoor Units 105

Wiring Diagrams MCAC-UTSM-2008-11 5.4 MOU-30HN1 MOU-36HN1 106 Outdoor Units

MCAC-UTSM-2008-11 Wiring Diagrams 5.5 MOU-30HN1-R MOU-36HN1-R Outdoor Units 107

Wiring Diagrams MCAC-UTSM-2008-11 5. 6 MOUA-48HN1-R MOUA-60HN1-R 108 Outdoor Units

MCAC-UTSM-2008-11 Electric Characteristics 6. Electric Characteristics Model Outdoor Unit Compressor OFM Hz Voltage Min. Max. MSC RLA KW FLA MOU-12HN1 50 220~240V 198V 254V 29.9 5.3 0.024 0.275 MOUA-18HN1 50 220~240V 198V 254V 36.8 8.7 0.048 0.48 MOUA-24HN1 50 220~240V 198V 254V 61 11.4 0.053 0.67 MOU-30HN1 50 220~240V 198V 254V 97 17.65 0.25 1.38 MOU-30HN1-R 50 380~415V 342V 418V 61 6.58 0.25 1.38 MOU-36HN1 50 220~240V 198V 254V 97 17.65 0.25 1.38 MOU-36HN1-R 50 380~415V 342V 418V 61 6.58 0.25 1.38 MOUA-48HN1-R 50 380~415V 342V 418V 63 8.3 0.065+0.065 0.7+0.7 MOUA-60HN1-R 50 380~415V 342V 418V 67 9.77 0.065+0.065 0.7+0.7 Remark: MSC: Max. Starting Amps. (A) RLA: Rated Locked Amps. (A) OFM: Outdoor Fan Motor. FLA: Full Load Amps. (A) KW: Rated Motor Output (kw) 7. Operation Limits Operation mode Outdoor temperature( ) Room temperature( ) Cooling operation 18~43 17~30 Heating operation -7~24 17~30 Cooling Heating 45 25 Outdoor temperature( DB) 40 35 30 25 20 STD Outdoor temperature( WB) 20 15 10 5 0-5 STD 15 10 15 20 25 30 35 Indoor temperature( WB) -10 10 15 20 25 30 35 Indoor temperature( DB) Outdoor Units 109

Sound Levels MCAC-UTSM-2008-11 8. Sound Levels For 12000~36000Btu/h For 48000,60000Btu/h Outdoor Unit Microphone H 1.0m Note: H= 0.5 height of outdoor unit Note: The point A is in the middle of the whole outdoor panel. Model Noise level db(a) MOU-12HN1 43 MOUA-18HN1 48 MOUA-24HN1 55 MOU-30HN1 57 MOU-30HN1-R 57 MOU-36HN1 57 MOU-36HN1-R 57 MOUA-48HN1-R 59 MOUA-60HN1-R 59.3 110 Outdoor Units

MCAC-UTSM-2008-11 Exploded View 9. Exploded View 9.1 MOU-12HN1 No. Part Name Quantity No. Part Name Quantity 1 Fan motor 1 10 High pressure valve ass'y 1 2 Motor bracket ass'y 1 10.1 High pressure valve 1 3 Rear net 1 10.2 Filter ass'y 1 4 Condenser ass'y 1 11 Base ass'y 1 5 E-part box ass'y 1 12 Grille 1 5.1 Wire joint,2p 1 13 Front panel 1 5.2 Wire joint,5p 1 14 Compressor 1 5.3 Compressor capacitor 1 15 Net Clamp 6 5.4 Motor capacitor 1 16 Right clapboard 1 6 4-way valve ass'y 1 17 Partition board ass'y 1 6.1 4-way valve 1 18 Left supporter 1 6.2 Low pressure valve 1 19 Motor bracket 1 7 Big handle 1 20 Top cover 1 8 Suction pipe 1 21 Axial flow fan 1 9 Valve plate 1 22 Temp.sensor ass'y 1 Outdoor Units 111

Exploded View MCAC-UTSM-2008-11 9.2 MOUA-18HN1 5.1/ 5.2 No. Part Name Quantity No. Part Name Quantity 1 Motor 1 12 Grille 1 2 Motor bracket ass'y 1 13 Front panel ass'y 1 3 Rear net 1 14 Valve plate 1 4 Condenser ass'y 1 15 Partition board ass'y 1 5 High pressure valve ass'y 1 16 Left supporter 1 5.1 High pressure valve 1 17 Big handle 1 5.2 Capillary 1 18 E-part box ass'y 1 6 Temp. sensor ass'y 1 18.1 Compressor capacitor 1 7 4-way valve ass'y 1 18.2 Motor capacitor 1 7.1 Low pressure valve 1 18.3 Wire joint,2p 1 7.2 4-way valve 1 18.4 Wire joint 1 7.3 Solenoid 1 18.5 Electric installation board 1 8 Right cover ass'y 1 19 Rear Supporter 1 9 Drainage pan 1 20 Top cover 1 10 Base ass'y 1 21 Axial flow fan 1 11 Compressor 1 23 R410A 112 Outdoor Units

MCAC-UTSM-2008-11 Exploded View 9.3 MOUA-24HN1 26 No. Part Name Quantity No. Part Name Quantity 1 Motor 1 13 Front panel ass'y 1 2 Motor bracket ass'y 1 14 Partition board ass'y 1 3 Rear net 1 15 Drainage cover 1 4 Condenser ass'y 1 16 E-part box ass'y 1 5 Condenser temp. sensor ass'y 1 16.1 Compressor capacitor 1 6 High pressure valve ass'y 1 16.2 Wire joint 1 6.1 High pressure valve 1 16.3 Wire joint,2p 1 6.2 Capillary 1 16.4 Wire joint 2 7 4-way valve ass'y 1 16.5 Contactor 1 7.1 Solenoid 1 16.6 Motor capacitor 1 7.2 4-way valve 1 17 Left supporter 1 7.3 Accumulator cylinder 1 18 Big handle 1 7.4 Low pressure valve 1 19 Handle 1 8 Right cover ass'y 1 20 Rear Supporter 1 9 Compressor 1 21 Top cover 1 10 Base ass'y 1 22 Axial flow fan 1 11 Valve plate 1 24 R410A 12 Grille 1 Outdoor Units 113

Exploded View MCAC-UTSM-2008-11 9.4 MOU-30HN1 MOU-36HN1 No. Part Name Quantity No. Part Name Quantity 1 Top cover ass'y 1 17 Copper nut 1 2 Rear Supporter 1 18 Copper nut 1 3 Motor bracket ass'y 1 19 Sphere pad 1 4 Fixing ring 1 20 Sphere pad 1 5 Accumulator cylinder 1 21 Temp. sensor ass'y 1 6 Motor 1 22 Discharge temp sensor 1 7 Suction pipe 1 23 Compressor electric heater 1 8 Condenser ass'y 1 24 Front panel 1 8.1 Condenser ass'y 1 25 Front net ass'y 1 8.2 Input pipe ass'y 1 26 Axial flow fan 1 8.3 Fluted pipe ass'y 1 27 Partition board ass'y 1 9 Rear right clapboard ass'y 1 28 Rear net 1 10 Front right clapboard ass'y 1 29 Left holder 1 11 4-way valve ass'y 1 30 E-part box ass'y 1 11.1 Low pressure valve 1 30.1 Wire joint 1 11.2 4-way valve 1 30.2 Wire joint 1 11.3 Solenoid 1 30.3 Electric installation board 1 12 High pressure valve ass'y 1 30.4 AC contactor 1 12.1 High pressure valve 1 30.5 Compressor capacitor 1 12.2 One way valve 1 30.6 Compressor capacitor 1 13 Valve plate 1 30.7 Resistance ass'y 1 14 Base ass'y 1 30.8 Capacitor 1 15 Compressor 1 30.9 Wire joint 2 16 Discharge pipe ass'y 1 30.10 Compressor relay 1 16.1 Muffler 1 31 Drainage cover 1 16.2 Pipe joint 1 32 Big handle 1 16.3 Pressure controller 1 114 Outdoor Units

MCAC-UTSM-2008-11 Exploded View 9.5 MOU-30HN1-R MOU-36HN1-R No. Part Name Quantity No. Part Name Quantity 1 Top cover ass'y 1 17 Temp sensor 1 2 Rear Supporter 1 18 Copper nut 1 3 Motor bracket ass'y 1 19 Copper nut 1 4 Fixing ring 1 20 Sphere pad 1 5 Accumulator cylinder 1 21 Sphere pad 1 6 Motor 1 22 Temp.sensor ass'y 1 7 Suction pipe 1 23 Discharge temp sensor 1 8 Condenser ass'y 1 24 Compressor electric heater 1 8.1 Condenser ass'y 1 25 Front panel 1 8.2 Input pipe ass'y 1 26 Front net ass'y 1 8.3 Fluted pipe ass'y 1 27 Axial flow fan 1 9 Rear right clapboard ass'y 1 28 Partition board ass'y 1 10 Front right clapboard ass'y 1 29 Rear net 1 11 4-way valve ass'y 1 30 Left holder 1 11.1 Low pressure valve 1 31 E-part box ass'y 1 11.2 4-way valve 1 31.1 Electric installation board 1 11.3 Solenoid 1 31.2 E-Part box 1 12 High pressure valve ass'y 1 31.3 Main control board ass'y 1 12.1 High pressure valve 1 31.4 Wire joint 3 12.2 One way valve 1 31.5 Transformer 1 13 Valve plate 1 31.6 Capacitor 1 14 Base ass'y 1 31.7 AC contactor 1 15 Compressor 1 31.8 Wire joint,4p 1 16 Discharge pipe ass'y 1 31.9 Wire joint, 5p 1 16.1 Muffler 1 32 Drainage cover 1 16.2 Pipe joint 1 33 Big handle 1 16.3 Pressure controller 1 Outdoor Units 115

Exploded View MCAC-UTSM-2008-11 9.6 MOUA-48HN1-R No. Part Name Quantity No. Part Name Quantity 1 Rear supporter 1 16 Front-right panel ass'y 1 2 Motor bracket ass'y 1 17 Front net ass'y 2 3 Condenser ass'y 1 18 Front panel 1 3.1 Input pipe ass'y 1 19 Rear-left supporting board 1 3.2 Output pipe ass'y 1 20 E-part box ass'y 1 4 Top cover 1 20.1 E-Part box 1 5 Partition board ass'y 1 20.2 Wire joint 3 6 Big handle ass'y 1 20.3 Wire joint, 5p 1 7 Rear-right panel 1 20.4 AC contactor 1 8 Low pressure valve ass'y 1 20.5 Main control board ass'y 1 8.1 4-way valve 1 20.6 Wire joint,4p 1 8.2 Solenoid 1 20.7 Transformer 1 8.3 Low pressure valve 1 20.8 Electric installation board 1 9 Valve plate 1 20.9 Motor capacitor 2 10 High pressure valve ass'y 1 21 Base 1 10.1 Strainer 1 22 Motor 1 10.2 High pressure valve 1 23 Motor 1 11 Discharge pipe ass'y 1 24 Axial flow fan 2 11.1 Pressure controller 1 25 Discharge temp sensor 1 12 Suction pipe ass'y 1 26 Temp sensor ass'y 1 12.1 Pressure controller 1 27 Room temp sensor ass'y 1 13 Compressor 1 28 Compressor electric heater 1 14 Separator 1 29 Compressor wire joint ass'y 1 15 Handle 2 116 Outdoor Units

MCAC-UTSM-2008-11 Exploded View 9.7 MOUA-60HN1-R No. Part Name Quantity No. Part Name Quantity 1 Rear supporter 1 16 Front-right panel ass'y 1 2 Motor bracket ass'y 1 17 Front net ass'y 2 3 Condenser ass'y 1 18 Front panel 1 3.1 Input pipe ass'y 1 19 Rear-left supporting board 1 3.2 Output pipe ass'y 1 20 E-part box ass'y 1 4 Top cover 1 20.1 E-Part box 1 5 Partition board ass'y 1 20.2 Wire joint 3 6 Big handle ass'y 1 20.3 Wire joint, 5p 1 7 Rear-right panel 1 20.4 AC contactor 1 8 Low pressure valve ass'y 1 20.5 Main control board ass'y 1 8.1 4-way valve 1 20.6 Wire joint,4p 1 8.2 Solenoid 1 20.7 Transformer 1 8.3 Low pressure valve 1 20.8 Electric installation board 1 9 Valve plate 1 20.9 Motor capacitor 2 10 High pressure valve ass'y 1 21 Base 1 10.1 Strainer 1 22 Motor 1 10.2 High pressure valve 1 23 Motor 1 11 Discharge pipe ass'y 1 24 Axial flow fan 2 11.1 Pressure controller 1 25 Discharge temp sensor 1 12 Suction pipe ass'y 1 26 Temp sensor ass'y 1 12.1 Pressure controller 1 27 Room temp sensor ass'y 1 13 Compressor 1 28 Compressor electric heater 1 14 Separator 1 29 Compressor wire joint ass'y 1 15 Handle 2 Outdoor Units 117

Troubleshooting MCAC-UTSM-2008-11 10. Troubleshooting 10.1. Self-diagnosis Indoor unit s LED indication (1) For the Four-way cassette During malfunction protection, digital pipe displays as follow: No Displaying contents Malfunction or protection 1 E2 Indoor temperature sensor is abnormal 2 E3 Evaporator temperature sensor is abnormal 3 E4 Condenser temperature sensor is abnormal 4 E5 Temperature sensor error of water pump 5 E6 Outdoor unit malfunction 6 E7 EEPROM malfunction 7 E8 Full-water malfunction (2) For the other types indoor unit No. Type Contents LED Flashing Remark 1 Normal Standing-by Operation lamp flashes at 0.5Hz 2 Normal System Off All lamps are off Nothing wrong with the 3 Normal System startup Operation lamp on unit when LED indicate 4 Normal Forced cooling Operation lamp flashes at 5Hz, these contents. Timer lamp on 5 Protection Lamps of operation, timer, Whole unit is shut Over current protection of the compressor defrosting (only fan) flashing down. It cannot recover occurs 4 times in 1h simultaneously at 5Hz. unless power is cut off 6 Protection Outdoor protection (lack of phase, phase sequence and temperature protection) All lamps flashing at 5Hz Room temperature sensor checking 7 Error 8 Error 9 Error channel is abnormal Evaporator sensor checking channel is abnormal Condenser sensor checking channel is abnormal 10 Error Communication of EEPROM malfunction 11 Error Water level alarm/pump sensor malfunction Timer lamp flashing at 5Hz Operation lamp flashing at 5Hz Defrosting lamp flashing at 5Hz Operation lamp and timer lamp flashing at 5Hz Alarm lamp flashes at 5Hz Recover automatically after errors are eliminated (For T3 malfunction of 5HP, can t recover automatically) (3) LEDs for the indication of outdoor trouble (3 phase type, 14, 16kW) Type Contents LED1 LED2 LED3 Trouble Phase sequence Flash Off Off Trouble Lack of phase(a,b) Flash Off Off Trouble Lack of phase(c) Off Off Off Trouble Protection of Low pressure Flash Flash Off Trouble Overload of current Off Off Flash Trouble Communication malfunction Flash Off Flash Trouble Open-circuit and short-circuit trouble of T3 Off Flash Flash Trouble Open-circuit and short-circuit trouble of T4(High discharge temperature protection) Off Flash Off Trouble High temperature protection of condenser Flash Flash Flash 118 Outdoor Units

MCAC-UTSM-2008-11 Troubleshooting 10.2 Solving steps for typical malfunction (1) For the new four-way cassette E2: Indoor temperature sensor is abnormal E2 Whether the resistance of the room temp. sensor is 10K No Replace temp. sensor Yes Replace the PCB E3: Evaporator temperature sensor is abnormal E3 Whether the resistance of the evaporator temp. sensor is 10K Yes No Replace evaporator temp. sensor Replace the PCB E4: Condenser temperature sensor is abnormal E4 Whether the resistance of the condenser temp. sensor is 10K No Replace condenser temp. sensor Yes Replace the PCB Outdoor Units 119

Troubleshooting MCAC-UTSM-2008-11 E5: Temperature sensor error of water pump E5 Whether the resistance of the temp. sensor is 10K No Replace temp. sensor Yes Replace the PCB E6: Outdoor unit malfunction E6 Whether the outdoor unit is power on No Check when the power is on Yes Measure whether the voltage of the communication line s red and black end between the indoor and outdoor unit is +5V No Replace the outdoor unit board Yes Check the indoor unit main board CN5 or replace the main control board Yes Replace the PCB 120 Outdoor Units

MCAC-UTSM-2008-11 Troubleshooting E7: EEPROM malfunction E7 EEPROM chip is broken Yes Replace EEPROM No Check whether the main control chip 9177 is broken Yes Replace 9177 chip No Check PCB board or replace the main control board E8: Full-water malfunction E8 Check whether the water-level switch is inserted well No Insert the water-level switch well Yes Check whether the water-level switch is broken Yes Replace the water-level switch No Check whether the water pump is normal No Replace the water pump Yes Check PCB board or replace the main control board Outdoor Units 121

Troubleshooting MCAC-UTSM-2008-11 (2) For the outdoor unit a. Phase sequence error: Phase sequence error Change the order of two of the wires to power supply. Switch on the unit again. If the problem can not be solved, the outdoor PCB is defective b. Overload of current Overload of current Check the current, normally Is the current in rated range? Yes The outdoor PCB is defective No Possible reason 1. Outdoor fan is defective 2. The compressor is defective 3. Refrigerant is over charged 4. Air enter the refrigerant system 5. Heat exchanger is too dirty c. Lack of phase Lack of phase Check the power supply, is it 3 phase, 380-415V? Yes Check the connection between power supply and terminal, is the voltage in outdoor terminal is 3 phase, 380-415V? Yes Outdoor PCB is defective 122 Outdoor Units

MCAC-UTSM-2008-11 Troubleshooting d. Protection of pressure or temp. Protection of pressure or temp. Yes Is it k1 or K2 open? Is temp. protective switch K1 open Is pressure protective switch K2 open Yes Yes Possible reason 1. The wires is loose to K1 2. Air or other gas in the refrigerant. 3. Heat exchanger is dirty 4. Outdoor fan or fan blade is defective 5. Outdoor unit is bad ventilation 6. Refrigerant is leakage 7. K1 switch is defective Possible reason 1. The wires is loose to K2 2. Air or other gas in the refrigerant. 3. Heat exchanger is dirty 4. Outdoor fan or fan blade is defective 5. Outdoor unit is bad ventilation 6. Refrigerant is two much 7. K2 switch is defective e. Open-circuit and short-circuit trouble of T3 Is connection to connector of temp. sensor good? No Yes Repair connector Check the resistance of the temp. sensor according to Annex 1 Is it the resistance is normal? Yes No Indoor PCB is defective. Replace the sensor Outdoor Units 123

Troubleshooting MCAC-UTSM-2008-11 f. Open-circuit and short-circuit trouble of T4 Is connection to connector of temp. sensor good? Yes No Check the resistance of the temp. sensor according to Annex 1 Repair connector Is it the resistance is normal? Yes No Indoor PCB is defective. Replace the sensor g. High temperature protection of condenser High temperature protection of condenser Check the resistance of the temp. sensor according to Annex 1, is it normal? Yes No Possible reason 1. Air or other gas in the refrigerant. 2. Heat exchanger is dirty 3. Outdoor fan or fan blade is defective 4. Outdoor unit is bad ventilation 5. Refrigerant is leakage 6. Outdoor PCB is defective Replace the sensor 124 Outdoor Units

MCAC-UTSM-2008-11 Troubleshooting Appendix Indoor Temp. and Pipe Temp. Sensor Resistance Value Table ( --K) K Ohm K Ohm K Ohm K Ohm -20 115.266 20 12.6431 60 2.35774 100 0.62973-19 108.146 21 12.0561 61 2.27249 101 0.61148-18 101.517 22 11.5000 62 2.19073 102 0.59386-17 96.3423 23 10.9731 63 2.11241 103 0.57683-16 89.5865 24 10.4736 64 2.03732 104 0.56038-15 84.2190 25 10.000 65 1.96532 105 0.54448-14 79.3110 26 9.55074 66 1.89627 106 0.52912-13 74.5360 27 9.12445 67 1.83003 107 0.51426-12 70.1698 28 8.71983 68 1.76647 108 0.49989-11 66.0898 29 8.33566 69 1.70547 109 0.48600-10 62.2756 30 7.97078 70 1.64691 110 0.47256-9 58.7079 31 7.62411 71 1.59068 111 0.45957-8 56.3694 32 7.29464 72 1.53668 112 0.44699-7 52.2438 33 6.98142 73 1.48481 113 0.43482-6 49.3161 34 6.68355 74 1.43498 114 0.42304-5 46.5725 35 6.40021 75 1.38703 115 0.41164-4 44.0000 36 6.13059 76 1.34105 116 0.40060-3 41.5878 37 5.87359 77 1.29078 117 0.38991-2 39.8239 38 5.62961 78 1.25423 118 0.37956-1 37.1988 39 5.39689 79 1.21330 119 0.36954 0 35.2024 40 5.17519 80 1.17393 120 0.35982 1 33.3269 41 4.96392 81 1.13604 121 0.35042 2 31.5635 42 4.76253 82 1.09958 122 0.3413 3 29.9058 43 4.57050 83 1.06448 123 0.33246 4 28.3459 44 4.38736 84 1.03069 124 0.32390 5 26.8778 45 4.21263 85 0.99815 125 0.31559 6 25.4954 46 4.04589 86 0.96681 126 0.30754 7 24.1932 47 3.88673 87 0.93662 127 0.29974 8 22.5662 48 3.73476 88 0.90753 128 0.29216 9 21.8094 49 3.58962 89 0.87950 129 0.28482 10 20.7184 50 3.45097 90 0.85248 130 0.27770 11 19.6891 51 3.31847 91 0.82643 131 0.27078 12 18.7177 52 3.19183 92 0.80132 132 0.26408 13 17.8005 53 3.07075 93 0.77709 133 0.25757 14 16.9341 54 2.95896 94 0.75373 134 0.25125 15 16.1156 55 2.84421 95 0.73119 135 0.24512 16 15.3418 56 2.73823 96 0.70944 136 0.23916 17 14.6181 57 2.63682 97 0.68844 137 0.23338 18 13.9180 58 2.53973 98 0.66818 138 0.22776 19 13.2631 59 2.44677 99 0.64862 139 0.22231 Outdoor Units 125

MCAC-UTSM-2008-11 Installation Part 4 Installation 1. Precaution on Installation... 128 2. Vacuum Dry and Leakage Checking... 129 3. Additional Charge... 130 4. Water Drainage... 131 5. Insulation Work... 133 6. Wiring... 134 7. Test Operation... 135 Installation 127

Precaution on Installation MCAC-UTSM-2008-11 1. Precaution on Installation 1.1. Measure the necessary length of the connecting pipe, and make it by the following way. a. Connect the indoor unit at first, then the outdoor unit. Bend the tubing in proper way. Do not harm them. CAUTIONS: Daub the surfaces of the flare pipe and the joint nuts with frozen oil, and wrench it for 3~4 rounds With hands before fasten the flare nuts. Be sure to use two wrenches simultaneously when you connect or disconnect the pipes. Pipe gauge Φ6.4 Φ9.5 Φ12.7 Φ15.9 Φ19.1 Tightening torque 15~16N.m (153~163 kgf.cm) 25~26N.m (255~265kgf.cm) 35~36N.m (357~367kgf.cm) 45~47N.m (459~480 kgf.cm) 65~67N.m (663~684kgf.cm) Flare dimension A Min (mm) Max 8.3 8.7 12.0 12.4 15.4 15.8 18.6 19.1 22.9 23.3 Flare shape b. The stop value of the outdoor unit should be closed absolutely (as original state). Every time you connect it, first loosen the nuts at the part of stop value, then connect the flare pipe immediately (in 5 minutes). If the nuts have been loosened for a long time, dusts and other impurities may enter the pipe system and may cause malfunction later. So please expel the air out of the pipe with refrigerant before connection. c. Expel the air after connecting the refrigerant pipe with the indoor unit and the outdoor unit. Then fasten the nuts at the repair-points. 1.2. Locate The Pipe a. Drill a hole in the wall (suitable just for the size of the wall conduit), then set on the fittings such as the wall conduit and its cover. b. Bind the connecting pipe and the cables together tightly with binding tapes. Do not let air in, which will cause water leakage by condensation. c. Pass the bound connecting pipe through the wall conduit from outside. Be careful of the pipe allocation to do no damage to the tubing. 1.3. Connect the pipes. 1.4. Then, open the stem of stop values of the outdoor unit to make the refrigerant pipe connecting the indoor unit with the outdoor unit in fluent flow. 1.5. Be sure of no leakage by checking it with leak detector or soap water. 1.6. Cover the joint of the connecting pipe to the indoor unit with the soundproof / insulating sheath (fittings), and bind it well with the tapes to prevent leakage. 128 Installation

MCAC-UTSM-2008-11 Vacuum Dry and Leakage Checking 2. Vacuum Dry and Leakage Checking 2.1. Vacuum Dry: use vacuum pump to change the moisture (liquid) into steam (gas) in the pipe and discharge it out of the pipe to make the pipe dry. Under one atmospheric pressure, the boiling point of water(steam temperature) is 100. Use vacuum pump to make the pressure in the pipe near vacuum state, the boiling point of water falls relatively. When it falls under outdoor temperature, the moisture in the pipe will be vaporized. 2.2. Vacuum dry procedure There are two methods of vacuum dry due to different construction environment: common vacuum dry, special vacuum dry.. Common vacuum dry procedure 1 Vacuum dry (for the first time)---connect the all-purpose detector to the inlet of liquid pipe and gas pipe, and run the vacuum pump more than two hours (the vacuum pump should be below -755mmHg) If the pump can t achieve below -755mmHg after pumping 2 hours, moisture or leakage point will still exist in the pipe. At this time, it should be pumped 1 hour more. If the pump can t achieve -755mmHg after pumping 3 hours, please check if there are some leakage points. Vacuum placement test: place 1 hour when it achieves -755mmHg, pass if the vacuum watch shows no rising. If it rises, it shows there s moisture or leakage point. Vacuuming from liquid pipe and gas pipe at the same time. Sketch map of common vacuum dry procedure. Installation 129

Additional Charge MCAC-UTSM-2008-11 2 Special vacuum dry procedure This vacuum dry method is used in the following conditions: There s moisture when flushing the refrigerant pipe. Rainwater may enter into the pipe. Vacuum dry for the first time 2h pumping 3. Vacuum destroy for the second time Fill nitrogen to 0.5Kgf/cm2 Because nitrogen is for drying gas, it has vacuum drying effect during vacuum destroy. But if the moisture is too much, this method can t dry thoroughly. So, please pay more attention to prevent water entering and forming condensation water. 4. Vacuum dry for the second time 1h pumping Determinant: Pass if achieving below -755mmHg. If -755mmHg can t be achieved in 2h, repeat procedure 3 and 4. 5. Vacuum placing test 1h 6. Sketch map of special vacuum dry procedure 3. Additional Charge Caution Refrigerant cannot be charged until field wiring has been completed. Refrigerant may only be charged after performing the leak test and the vacuum pumping. When charging a system, care shall be taken that its maximum permissible charge is never exceeded, in view of the danger of liquid hammer. Charging with an unsuitable substance may cause explosions and accidents, so always ensure that the appropriate refrigerant is charged. Refrigerant containers shall be opened slowly. Always use protective gloves and protect your eyes when charging refrigerant. The outdoor unit is factory charged with refrigerant. Calculate the added refrigerant according to the diameter and the length of the liquid side pipe of the outdoor unit/indoor unit R(g) L(m) D(mm) φ6.4 Φ9.5 Φ12.7 Less than 5m (One-way) Added Refrigerant When Over 5m(One-way) 11g/m (L-5) 30g/m (L-5) 60g/m (L-5) Remark: R(g): Additional refrigerant to be charged L(m): The length of the refrigerant pipe(one-way) D(mm): Liquid side piping diameter 130 Installation

MCAC-UTSM-2008-11 Water Drainage 4. Water Drainage 4.1. Gradient and Supporting 4.1.1 Keep the drainpipe sloping downwards at a gradient of at least 1/100. Keep the drainpipe as short as possible and eliminate the air bubble. 4.1.2 The horizontal drainpipe should be short. When the pipe is too long, a prop stand must be installed to keep the gradient of 1/100 and prevent bending. Refer to the following table for the specification of the prop stand. Diameter Hard PVC pipe 25~40mm 1.5~2m Distance between the prop stands 4.1.3. Precautions 1 The diameter of drainpipe should meet the drainage requirement at least. 2 The drainpipe should be heat-insulated to prevent atomization. 3 Drainpipe should be installed before installing indoor unit. After powering on, there is some water in water-receiver plate. Please check if the drain pump can operate correctly. 4 All connection should be firm. 5 Wipe color on PVC pipe to note connection. 6 Climbing, horizontal and bending conditions are prohibited. 7 The dimension of drainpipe can t less than the connecting dimension of indoor drainpipe. 8 Heat-insulation should be done well to prevent condensation. 9 Indoor units with different drainage type can t share one convergent drainpipe. 4.2 Drainpipe Trap 4.2.1. If the pressure at the connection of the drainpipe is negative, it needs to design drainpipe trap. 4.2.2. Every indoor unit needs one drainpipe trap. 4.2.3. A plug should be designed to do cleaning. Plug 50cm 50cm 4.3 Upwards drainage(drain pump) For Four-way cassette(compact) Installation 131

Water Drainage MCAC-UTSM-2008-11 For Four-way cassette 4.4 Convergent drainage 4.4.1. The number of indoor units should be as small as possible to prevent the traverse main pipe overlong. 4.4.2. Indoor unit with drain pump and indoor unit without drain pump should be in different drainage system. 4.4.3. Selecting the diameter Number of connecting indoor units Calculate drainage volume Select the diameter Calculate allowed volume =Total cooling capacity of indoor units(hp) 2 (l/ hr) Allowed volume(lean 1/100) (l/ hr) I.D. (mm) Thick 集中排水管 Hard PVC 14 25 3.0 Hard PVC 14< 88 30 3.5 Hard PVC 88< 334 40 4.0 Hard PVC 175< 334 50 4.5 Hard PVC 334< 80 6.0 4.5 Drainage test Drainage without drain pump After finishing drainpipe installation, pour some water into the water receiver plate to check if the water flows smoothly. 132 Installation

MCAC-UTSM-2008-11 Insulation Work 5. Insulation Work 5.1 Insulation material and thickness 5.1.1. Insulation material Insulation material should adopt the material which is able to endure the pipe s temperature: no less than 70 in the high-pressure side, no less than 120 in the low-pressure side(for the cooling type machine, no requirements at the low-pressure side.) u Example: Heat pump type----heat-resistant Polyethylene foam (withstand above 120 ) Cooling only type----polyethylene foam (withstand above 100 ) 5.1.2. Thickness choice for insulation material Insulation material thickness is as follows: Pipe diameter (mm) Adiabatic material thickness Φ6.4 Φ25.4 10mm Refrigerant pipe Φ28.6 Φ38.1 15mm Drainage pipe Inner diameterφ20 Φ32 6mm 5.2 Refrigerant pipe insulation 5.2.1. Work Procedure 1 Before laying the pipes, the non-jointing parts and non-connection parts should be heat insulated. 2 When the gas proof test is eligible, the jointing area, expanding area and the flange area should be heat insulated 5.2.2. Insulation for non-jointing parts and non-connection parts wrong right Gas pipe and liquid pipe should not be put together to insulate Insulate the gas pipe (cooling only) Insulate the gas pipe and liquid pipe Installation 133

Wiring MCAC-UTSM-2008-11 For construction convenience, before laying pipes, use insulation material to insulate the pipes to be deal with, at the same time, at two ends of the pipe, remain some length not to be insulated, in order to be welded and check the leakage after laying the pipes. 5.2.3. Insulate for the jointing area, expanding area and the flange area 1 Insulate for the jointing area, expanding area and the flange area should be done after checking leakage of the pipes 2 Make sure there s no clearance in the joining part of the accessorial insulation material and local preparative insulation material. 5.3 Drainage pipe insulation The connection part should be insulated, or else water will be condensing at the non-insulation part. 5.4 Note 5.4.1 The jointing area, expanding area and the flange area should be heat insulated after passing the pressure test 5.4.2 The gas and liquid pipe should be heat insulated individually, the connecting part should be heat insulated individually. 5.4.3 Use the attached heat-insulation material to insulate the pipe connections (pipes tie-in,expand nut ) of the indoor unit 6. Wiring Please refer to the Wiring Diagram. 134 Installation

MCAC-UTSM-2008-11 Test operation 7. Test operation (1) The test operation must be carried out after the entire installation has been completed. (2) Please confirm the following points before the test operation. The indoor unit and outdoor unit are installed properly. Tubing and wiring are correctly completed. The refrigerant pipe system is leakage-checked. The drainage is unimpeded. The ground wiring is connected correctly. The length of the tubing and the added stow capacity of the refrigerant have been recorded. The power voltage fits the rated voltage of the air conditioner. There is no obstacle at the outlet and inlet of the outdoor and indoor units. The gas-side and liquid-side stop values are both opened. The air conditioner is pre-heated by turning on the power. (3) According to the user's requirement, install the remote controller when the remote controller's signal can reach the indoor unit smoothly. (4) Test operation Set the air conditioner under the mode of "COOLING" with the remote controller, and check the following points. Indoor unit Whether the switch on the remote controller works well. Whether the buttons on the remote controller works well. Whether the air flow louver moves normally. Whether the room temperature is adjusted well. Whether the indicator lights normally. Whether the temporary buttons works well. Whether the drainage is normal. Whether there is vibration or abnormal noise during operation. Outdoor unit Whether there is vibration or abnormal noise during operation. Whether the generated wind, noise, or condensed of by the air conditioner have influenced your neighborhood. Whether any of the refrigerant is leaked. Installation 135

Control MCAC-UTSM-2008-11 Part 5 Control 1. Remote Controller... 137 136 Control

MCAC-UTSM-2008-11 1. Remote Controller 1.1 R11-HG/E Mode select button Each time you push the button, a mode is selected in a sequence that goes from AUTO, COOL, DRY, HEAT (cooling only type without), FAN ONLY and back to AUTO. I/O Button Push the button to start operation, push the button again to stop operation. Remote Controller Fan button Temperature Button This button is used for selecting fan speed. Each time you push the button, a fan speed is selectedinasequence that goes from AUTO, LOW, MED(Some models without, HIGH, and back to AUTO. After Sliding the cover, the button and function are as follows: Auto louver button Push this button to swing louver. Push the button again to stop. Confirmation button Push this button to confirm ON and OFF timer settings. FAN Timer button Push ON-TIME timer button to set the ON timer. Push OFF-TIME timer button to set the OFF timer. This button is used for setting the current time and OFF time. Adjust forwards Adjust backwords Clock button Push this button to set time. Push this button to cancel ON timer and OFF timer. Lock button When you push the LOCK button, all current settings are locked in and the remote controller does not accept any operation except that of the LOCK button. Use the lock mode when you want to prevent setting from being changed accidentally or play fully. Push the LOCK button again when you want to cancel the LOCK mode. RESET button When you push the RESET button, all current settings are cancelled and get into the condition of beginning. In the clock, the colon in "0:00" will flash, the mode displays "AUTO", fan speed displays "AUTO", the temperature displays "24". Control 137

Remote Controller MCAC-UTSM-2008-11 1.2 R05/BGE The below is R05/BGE wireless remote controller, for Four-way cassette type and the Ceiling& floor type. Mode setting 1 AUTO COOL DRY HEAT TEMP SET SET 2 Fan speed setting Adjust 3 FAN 4 Adjust MODE M FAN SPEED ON/OFF 5 6 Ai r dire cti on setting Horiz swing 7 9 Time setting SWING AIR DIRECTION CLOCK Vert. swing 8 SWING OK TIME ON 10 Time ON Reset 12 ECO TIME OFF 11 Time OFF Lock 13 14 Confirm button Cool/heat 15 16 Economic operation Visual photo 1.3 General Function for wireless remote controller: MODEL AND SPECIFICATION Model R05/BGE Rated voltage 3.0V (2 pieces of LR03 7# batteries) Min voltage for sending signal of CPU 2.4V Effective receiving distance 8m~11m Operation condition -5~60 138 Control