EASY ZONE TOUCH. User Manual. 6 Zone Control System with Active Temperature Management. Ver 1.0

Similar documents
Elegance. SMT-700 User manual. Ver

User & Installer Manual SMT-400 "Enterprise" Wi-Fi Thermostat

Product Manual SZ1009

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Model: Available in: Sapphire Black and Glacier White. 1 Series

IFT-RC400 IntelliFire Touch Remote Control

User Manual. Dryer Controller M720

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

DEFA HOME. User Manual Base Unit PRO

Carbon Monoxide Transmitter

Dryer Controller M720

Model: Touch-RS. 1 Touch-RS

Database for CTS6000 MODBUS

Safety & Installation Instructions

Operation Guide CT80 ENGLISH

Product Manual SZ1022/SZ1031/SZ1035/

Watchguard WGAP864 User Manual

Challenger Series Users Manual

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

T-32-TS Touchscreen Thermostat. Installation Manual

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

Model: Available in : Sapphire Black and Glacier White. 1 Series

Installer Manual SMT 770 Chameleon Multifunction Thermostat. Ver 3.0

Integrated PIR detectors

Safety & Installation Instructions

RCS Residential Control Systems Inc.

CONTROL ZONE Smart Temp. SMT-700 Installer Manual. Ver 3.0

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

Contents. Glossary Introduction to the IDS Notes Understanding the Keypad Indicators Operation of the Keypad...

Safety & Installation Instructions

SAT-3 Room Temperature Controller

4286/4500 Voice Module Set up and Troubleshooting

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

FPC-02 Series. Installation and Operating manual

Safety & Installation Instructions

Operating Instructions READ AND SAVE THESE INSTRUCTIONS

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

Installation Manual for Hot Yoga Studio Electric Radiant Heating Version 3.0

P2267 NETWORK INTERFACE

Installation Manual for Hot Yoga Studio Electric Radiant Heating

Model: Edge-HC. 1 edge-hc

Installation and Setup Guide

IDS816 User Manual H Issued January 2009

Model: Slimline-N. 1 Slimline Series

VENSTAR T1075 FAN COIL THERMOSTAT 7 DAY PROGRAMMABLE 2 OR 4 PIPE SYSTEMS OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

EL-TSTAT-8820 Safety & Installation Instructions

Brivis Zoning Technology. If you think heating or cooling your whole home is a waste of energy consider zoning

2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX FEATURES APPLICATION MANUAL

ST9400A User Guide. Features

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

IDS800 USER MANUAL. Summary of Operation. + [ ] 2 IDS800 USER MANUAL NO K ISSUED APR 2003 VER 1.44

Security System. User s Guide for the Text Command Center

U ser's Guide PC6010

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

Rotem One Touch. User Manual PRELIMINARY DOCUMENT. Ag/MIS/UmGB /18 Rev 1.0 P/N:

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

USER MANUAL WARNING! CONTENTS MODEL SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING

- Data Brochure tekmarnet 4 Thermostat 542e

Control4 Wireless Thermostat by Aprilaire. Safety and Installation Guide

SmartVent. Digital Controller User Guide Manual. NZ s Home Ventilation Specialists

CS027 User Instructions

SmartVent. Keypad Controller User Guide Manual. NZ s Home Ventilation Specialists

Model: PRT-TS / PRT-NTS

Contents. Glossary

Brivis Zoning Technology

- Data Brochure Steam Control 279

Fire Command Keypad. XR5 User s Guide

Smart Temp. Model

Table of Contents About This User s Guide... 2 Introduction... 2 Security System Basics... 3 What is a Point?... 3 What is a Faulted Point?...

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

Installer Manual KNX Touchscreen Thermostat

OWNERS MANUAL YEAR LIMITED WARRANTY READ ALL INSTRUCTIONS BEFORE PROCEEDING. Store this booklet for future reference

RC-2000 Thermostat Installation Instructions

Instruction Guide: Thermostat Operation

EZY SWITCH. SMS-IRR-4 System Monitor Installation Manual

User s Manual

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

Comfort System T-21-P Touchscreen Thermostat Installation Manual

USER MANUAL Comfort System4 TM

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

The easier, smarter heating system. Multi-zone heating made easy. User guide Setup and control

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

Analog Room Pressure Monitor RPC Series

SMART SWITCH TECHNOLOGIES. SmartSwitch Yacht-Guard Model SMS-8 Vessel System Monitor Installation Manual

To operate the 5207 you can use either the built-in touchpad or the Model 5230 Remote Annunciator.

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

XLH210: controller for gas leak detectors

Smart Energy Programmable Thermostat + Energy Monitor. EE542-1Z I User Manual

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features


INTRODUCTION WHAT THE EMS-1000 IS DESIGNED TO DO HOW THE EMS-1000 OPERATES EMS CONTROL PANEL INITIAL SETUP SETUP CLOCK DIGITAL DISPLAY

Brivis Zoning Technology. If you think heating or cooling your whole home is a waste of energy consider zoning

Model: RT510RF. Installation Manual

System. For a better understanding of this product, please read this user manual thoroughly before using it.

Peak Partners Web-Programmable Thermostat Homeowner s Manual. Look inside for a complete guide to the setup and operation of your new thermostat.

Transcription:

EASY ZONE TOUCH 6 Zone Control System with Active Temperature Management User Manual Ver 1.0

Preface Your new air conditioning zone control system has been built using the best components and design philosophy currently available. As a result, if properly installed your Smart Temp EASY ZONE TOUCH will provide you with many years of trouble free comfort control. The EASY ZONE TOUCH control system has been designed and built by Smart Temp Australia P/L to be an attractive, highly reliable and an easy to use controller. By taking the time to read and understand these simple instructions you can take advantage of many of the capabilities that are offered in this premium product. Great care has been taken in the preparation of this manual. Smart Temp Australia P/L takes no responsibility for errors or omissions contained in this document. It is the responsibility of the user to ensure this controller, or equipment connected to it is operating to their respective specifications and in a safe manner. Due to ongoing product improvement Smart Temp Australia P/L reserves the right to change the specifications of the EASY ZONE TOUCH (or its components) without notice. All rights reserved. Smart Temp Australia P/L 2009 Intellectual rights apply. Page 2

Index Preface 2 Index 3 Introduction 4 What Is Zoning? 4 Operation 6 Turing a Zone on or off 8 Setting the Zone Active Temperature 8 To adjust the zone temperatures 8 Performing a Reset 10 Specifications 12 Page 3

Introduction Thank you for choosing Smart Temp Australia P/L for your heating, cooling or air conditioning system zone control management. You have chosen a product built to exceptional standards and that offers that latest s technology in energy management and comfort control. Please take the time to read these instructions and familiarise yourself with the features and functions found in this product. Although the EASY ZONE TOUCH works well with any thermostat, its many features can be fully utilised when paired with a compatible thermostat, such as the Smart Temp SMT 770 Chameleon thermostat. As the EASY ZONE TOUCH is capable of being a part of many different types of heating cooling and air conditioning systems. It is beyond the scope of this manual to describe them all. So whether your EASY ZONE TOUCH is connected to inverter, air conditioning system, reverse cycle system, heat pump system, gas/oil heater or HVAC system this manual describes these collectively as a heating and cooling system. What Is Zoning? Climate system zone control allows the user managed distribution of conditioned air (warmed or cooled) to specific arrears of your home or office to permit you to increase the comfort levels or to reduce energy costs in your home or office. Just as your home or office has a number of light switches to control which rooms are lit, your zone control system permits you to control which rooms are heated or cooled and in most circumstances, what temperature is maintained in these rooms (or zones). When using a zone control system, it is important that realistic demands are made on the system such as keeping all the zones desired temperatures to within 5 to 8c of other zone temperatures or of the master controlling thermostat. Page 4

Advantages of Zoning Reduced energy Costs Zoning permits you to reduce your energy costs by not heating or cooling an area of your home or office that is vacant. Shutting unused zones sends all available capacity of your heating or cooling system to zones that are occupied, enabling them to reach set temperature faster saving energy. Rapid temperature recovery By shutting down less important zones on particularly hot or cold days will bring more important zones to set temperature more quickly. Turn off the unoccupied bedrooms during day to ensure the living area temperature is effortlessly and efficiently maintained. More even temperature Control The EASY ZONE TOUCH will enable you to turn zones off manually when they become too warm or cool, so turn off upstairs when the temperature is warm enough while leaving downstairs to continue to heat. The EASY ZONE TOUCH can automatically shut some zones down when a zone preset temperature has been reached if configured by your installer. Smaller Heating or cooling system required. As zoning is such an energy efficient method of climate control, it is recommended that a smaller than normally required heating and cooling system be used. This saves money as a capitol investment and in ongoing energy bills. Disadvantages of Zone control Many heating and cooling systems must maintain a minimum volume of air through the system for them to work effectively. As zones are closed the volume of air through the heating and cooling system may be reduced and if too many zones are simultaneously closed while the heating and system is running, the heating and cooling system may shut down to protect itself. The EASY ZONE TOUCH will attempt to prevent this by automatically opening all zones if it detects stress on the heating and cooling system. Further, shutting too many zones down will increase air velocity through the open zones which now may become noisy. Using a thermostat such as the Smart Temp SMT 770 that can control fan speeds on a compatible heating and cooling systems will permit you to manually select a lower fan speed to eliminate or reduce this problem. Page 5

Operation The Easy Zone touch is a microprocessor based device capable of actively controlling up to 6 temperature controlled zones. It is also fitted with a LCD membrane that is touch sensitive making using the zone controller a very simple matter. Without applying great pressure and using your finger tip or fingernail you are able to operate the system and turn zones on or off and set zone temperatures as required. The EASY ZONE TOUCH will respond to all valid touch commands with a confirming beep and the new status will be displayed on the LCD. Screen layout Zone Name Your EASY ZONE TOUCH has been provided with a library of standard names that can be associated with each zone button. This makes it simple to remember which button is used to control which zone in your office or home. Custom names can also be entered if necessary 1. Your installer will have set these names during the setup and commissioning of the system. A list of the standard available names has been provided in appendix 1 at the rear of this document (page 10). Your EASY ZONE TOUCH will be setup by your installer to either simply open or close the zone(s) or to report the zone temperature to the controlling thermostat or actively and automatically open and close the zones based on zone and set temperatures. 1 Custom Zone Names require the use of modbus communication software to edit the name registers within the Eazy Zone Touch memory. This will require special tools. Page 6

Zone Status Tapping the zone button will permit you to cycle between the available modes as set by your installer. Pressing and holding the zone button will enable Active Zone temperature adjustments if enabled. Zone Off Zone ON Zone Sensing Zone Active This is showing that the Rumpus zone is OFF. No conditioned air will be sent to this zone. This is showing that the Rumpus zone is ON. This zone is receiving conditioned air from your heating and cooling system. This is showing that the Rumpus zone is ON, and the temperature in this zone is being monitored by your heating and cooling system which will then control the system accordingly. This is showing that the Rumpus zone heating and cooling desired temperatures are being actively maintained by the EASY ZONE TOUCH. System messages Various messages will be shown in this section of the screen to alert, inform or assist the user in the use of the EASY ZONE TOUCH control panel. See appendix 2 (Page 11) Clean Press this button to temporarily disable the EASY ZONE TOUCH buttons so that you can clean the LCD (with a moist, chemical free soft cloth) without altering any settings. Screen Calibration Pressing and holding the Clean button for 3 seconds will permit you to calibrate the touch screen, simply follow the instructions on the screen and touch the two points when prompted. Note: It is recommended that when calibrating the screen that you use the cap of a ball point pen or other blunt pointy device for greater accuracy. This normally only needs be done once. Page 7

Turning a Zone on or off Tap the zone name to toggle the zone between On or OFF modes. If enabled by the installer, tapping this button again will also permit you to select Sensing mode where the zones temperature will be used by the thermostat to control the heating and cooling system to control that zones temperature. As each tap of the button is detected a Beep will be heard and the status of the zones will change. Again, if enabled by the installer you can press and hold the zone button to permit Active zone temperature control where the EASY ZONE TOUCH will limit the zone temperature independently of the main thermostat. To turn Active mode off simply tap that zone button again. Setting the Zone Active Temperature (if function enabled) The Easy Zone has the ability to monitor the zone temperature and, if enabled by the installer automatically open or close the zone based on the current zone temperature, the current room temperature and the current status of the heating and cooling system. So, if the zone is a little warm and the heating system starts, the EASY ZONE TOUCH will automatically close the zone to prevent the zone from further overheating. If the cooling starts the EASY ZONE TOUCH will open the zone to permit the zone to cool to the cooling set temperature if necessary. The heating set temperature should always remain lower than the cooling set temperature. To adjust the zone temperatures Press and hold the zone button for 1 second, the LCD will change to show the zone temperature adjustment screen as shown below. Page 8

Zone name This is the name of the zone where these settings are applied. Zone temperature The current zone temperature. Cooling When the cooling system is running the EASY ZONE TOUCH will close the zone damper when the room temperature is at or below this value. Touch the temperature to select it for adjustment with the temperature set button. It will highlight to show it has been selected. (Cooling is selected in the above example). Heating When the heating system is running the EASY ZONE TOUCH will close the zone damper when the room temperature is at or above this value. Touch the temperature to select it for adjustment with the temperature set button. It will highlight to show it has been selected. (Cooling is selected in the above example). Zone Status This shows whether this zone is receiving conditioned air based on the room & set temperatures and the mode of the air conditioning system. In the above example the zone has been automatically selected to off by the EASY ZONE TOUCH, as the current room temperature is between the desired heating and cooling set temperatures. Temperature Set Buttons Select the heating or cooling desired temperature and then adjust with these buttons. Back Select back to save changes and return to the previous menu, or wait 30 seconds and the easy Zone Touch will automatically return to the previous menu. Page 9

EASY ZONE TOUCH Safety Systems As the EASY ZONE TOUCH does not directly control the heating and cooling system, (turn the heating & cooling system on or off directly) it simply reports the zone temperatures to the standard supplied controller (thermostat). The standard thermostat then controls the heating and cooling system based on the sensing zone temperatures and thermostats set point. This zone control strategy offers the most flexible control and impacts least on the heating and cooling system electronics thereby protecting warranties. Given the wide variety of heating and cooling system capable of being controlled by the EASY ZONE TOUCH, a number of innovative passive and active protection strategies have been incorporated into the EASY ZONE TOUCH design to protect the heating and cooling system hardware. Therefore, depending on the requirements of your installation you may find that the EASY ZONE TOUCH makes some demands of you as setup by the installer. Some restrictions may include some or all of the following Not being permitted to close all zones simultaneously. Not being able to open all zones simultaneously. Keeping at least one zone as a Sensing zone at all times. Limiting the maximum number of Active zones. System messages on the status bar will guide you in using the EASY ZONE TOUCH. For example, if you want to close the bedroom zone and you not permitted, simply open another zone first and then try closing the bedroom zone. This ensures that a sufficient number of zones are open at all times to maintain the necessary air flow through the heating and cooling system for safe operation. Performing a Reset The EASY ZONE TOUCH is a microprocessor based device and in rare circumstances, as a consequence of power surges or the like, may seem erratic or show garbled data and need to be reset. Simply press the reset button with a thin blunt object such as a ball point pen or a straightened paper clip to perform this function. No user or installer settings will lost. Appendix 1 Available Zone names Master Girls Room Boys Room Nursery Bed 1 Bed 2 Bed 3 Bed 4 Dining Family Living Lounge Rumpus Games TV room Play Room Study Guest Theatre Bathroom Downstairs Upstairs Spare Room Pool Kitchen Kids Room Laundry En suite Alfresco User defined Page 10

Appendix 2 Status messages Message Max Number of Active Zones reached Spill Opened System mode is Heating System mode is Cooling Memory Chip Failure System temperature is too low System temperature is too high System Sensor Fault Communication breakdown Zone Sensor Fault Please Select Another Open Zone First Please Select Another Sensing Zone First Less than Minimum Open Zones More than Maximum Active Zones Open at least A Active Zones Explanation A limit on the maximum number of temperature controlled Sensing zones may be set by the installer. This limit has been reached. The EASY ZONE TOUCH may open a Spill zone to reduce the air pressure in the system caused by too many zones closed. The Easy Zone touch believes the heating system is running as the air in the vents is warm. The Easy Zone touch believes the cooling system is running as the air in the vents is cool. This is a critical fault call for service. The EASY ZONE TOUCH believes the air in the ducting is too cold, so it is trying to correct this situation by opening more zones. This is normal operation but you should call for service if this message appears often. The EASY ZONE TOUCH believes the air in the ducting is too warm, so it is trying to correct this situation by opening more zones. This is normal operation but you should call for service if this message appears often. The sensor monitoring the heating and cooling system duct temperature is missing or faulty. Call for service. This is a critical fault call for service A zone temperature sensor is missing or faulty. Call for service. You have reached the safe minimum number of closed zones. Before trying to close another zone, open an extra zone first. You must have at least one zone selected as a sensing zone so please selects another zone before closing any sensing zone. You must maintain a minimum number of open zones at all times. The limit on the maximum number of Active zones has been reached. You must maintain a minimum number of Active zones at all times. Page 11

Specifications Wall Controller Input Voltage 24VAC 50/60 Htz +/ 15%. Operating Temperature 0 50C (32 to 122F). Operating RH 0 95% (non condensing). Storage Temperature 0 65C (32 to 150F). Size 113 x 103 x 23mm. Display Size 69.5 x 46.3mm. Backlight White or blue EL (30 seconds after last button press) Display type 240 x 320 pixel FSTN touch panel Memory type Non volatile Settings do not require battery backup. Communications Modbus RTU 9600baud 1 stop bit 1 start bit no parity (adjustable) Main Relay Card Input Voltage 24VAC 50/60 Htz +/ 15%. Operating Temperature 0 50C (32 to 122F). Operating RH 0 95% (non condensing). Storage Temperature 0 65C (32 to 150F). Size 110 x 200mm. Memory type Non volatile Settings do not require battery backup Zone / Spill Relays 24V @ 2amps max Zone Sensor input 2 to 50K (10KTypeII NTC required for advanced mode). AC sensor input 10KTypeII NTC only (Smart Temp PN Rs 1D) Common Approvals Warranty FCC (Part 15) (pending), C tick. 3 years RTB. Date Installed Installed By Page 12