BTL Two-Way Low Profile Evaporators

Similar documents
KTL Two-Way Low Profile Evaporators

KTL Two-Way Low Profile Unit Coolers

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

ThermoSaver TM Hot Gas Defrost System

TLV Low Velocity Evaporators

High Profile Evaporator

Half Round Evaporators

TPLP Pre-Assembled. Low Profile Evaporators CONTENTS PRODUCT DATA & INSTALLATION. Air & Electric Defrost

Low Profile Unit Coolers

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

Low Profile Unit Coolers

TPLP PRE-ASSEMBLED LOW PROFILE EVAPORATORS

Installation, Operation, and Maintenance Information

Center Mount Unit Coolers

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

KR Electrical Defrost Unit Coolers (PN E108318_E)

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

KR Series Air Defrost Unit Coolers Operating and Installation Manual

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

ThermoSaver TM Hot Gas Defrost System

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

LOW PROFILE UNIT COOLER

IOM 410. Installation Operation Maintenance Information. UNIT COOLERS Super-Flo (SD Models) Easy-Flo (EF Models) Table of Contents

Super-Flo Low Profile Unit Cooler

LOW PROFILE UNIT COOLER

Low Flow Unit Coolers

Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

CONDENSING UNITS-AIR SUBMITTED BY : Poppy Hudson PROJECT : Brooks Landing REV DATE : 07 Dec 2017 ORDER # : A00

Electric Space Heater

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

INSTALLATION AND OPERATING MANUAL

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

INSTALLATION AND OPERATING MANUAL

Air-Cooled Condensing Units with Compact Screw Compressors

Unit Coolers. Installation and Operations Manual. Table of Contents. H-IM-UC November 2017 Part No

INDOOR, SUSPENDED, STEAM OR HOT WATER HYDRONIC UNIT HEATER FOR VERTICAL OR HORIZONTAL CONFIGURATION

R E D I C O N T R O L S

InstructIon Manual KrEs EQuIPMEnt stands

KR Series COMPACT UNIT COOLERS. Technical Bulletin: KRUC_005_ Products that provide lasting solutions.

Field Top Mounted Condensing Unit

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR INDUSTRIAL COOLERS

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

INSTRUCTIONS! DO NOT DISCARD!

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June

WKS 4000 SERIES (USA only) --INSTALLATION INSTRUCTIONS--

WMWLB / WMWFM / WTWLB / WTWFM Series Hydronic Heating Unit

REFRIGERATED DROP-INS (2-6)FT-DI Installation and Operating Manual

MANUAL 8/12/05. Model BKP TM 100 INSTALLATION, OPERATION & MAINTENANCE. Commercial High Efficiency Heat Pipe Dehumidifier

KCS-Line Air Cooled Condensers

MYSTICOOL Max Valve System with Xstream and A.R.M.E.D. Technology Service & Installation Instructions Page 1

INSTALLATION AND OPERATING MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

Superdryer Dehumidifiers

Installation & Maintenance Instructions

XSTREAM Valve System With A.R.M.E.D. Technology Service & Installation Instructions Page 1

Installation, Operation, and Maintenance Information

DOLE REFRIGERATING COMPANY 1420 Higgs Road Lewisburg, Tennessee Phone (931)

LV Installation Manual

Condensing Unit Installation and Operating Instructions

MODELS B1PA024, 030 AND 036

Horizontal Bottle Cooler Installation and Operation Manual

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

POLAR TEMP FARM MORTALITY UNIT OPERATION MANUAL

Installation, Operation & Service Manual

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS WALK-IN COOLERS SERIES LS-LP-LA-LV

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS FOR LOW PROFILE-UNIT COOLERS AND DUAL FLOW UNIT COOLER

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.

COMMERCIAL AIR COOLERS AIR AND ELECTRIC DEFROST

Turbo Air Speed up the Pace of Innovation TBB-4SB CAUTION! PLEASE KEEP POWER SWITCH ON BEFORE OPERATING THIS EQUIPMENT

INSTALLATION AND OPERATING MANUAL

APPLICATION MANUAL FOR SCU SERIES COMPRESSOR UNITS AND SWU SERIES WATER COOLED CONDENSING UNITS

CWA4 Chilled & Hot Water Fan Coil

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CS/CD/CP AIR COOLED CONDENSING UNITS (P/N E207120C R2)

COMMERCIAL AIR COOLERS AIR, ELECTRIC AND HOTGAS DEFROST

ENGINEERING SPECIFICATIONS

Owner s Manual Refrigerated Compressed Air Dryers Models F-200, 250, 300 & F350

Slim Contour Unit Cooler

COMMERCIAL AIR COOLERS AIR AND ELECTRIC DEFROST

ENGINEERING SPECIFICATIONS

Spa Control System OWNER S MANUAL

INSTRUCTIONS! DO NOT DISCARD!

MHH. 13 SEER High Efficiency R410a. SPECIFICATION sheet

Refrigerator Freezer Installation and Operation Manual

Model No. Serial No. Original Purchaser. Address. City and State Zip. Dealer. Address. City and State Zip. Installation Date Name Signature

Electric Duct Heaters

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Installation and Owner Man u al

COMMERCIAL AIR COOLERS AIR, ELECTRIC AND HOTGAS DEFROST

Transcription:

PRODUCT DATA & INSTALLATION Bulletin B30-BTL-PDI-3 1087832 Latest product updates and further information at w ww.ballyrefboxes.com BTL Two-Way Low Profile Evaporators High, Medium and Low Temperature Applications -10 F (-23.3 C) and above Air or Electric Defrost Electrical Power: 115/1/60, 208-230/1/60 CONTENTS Nomenclature... 2 Features... 2 Capacity Data (Imperial and Metric)... 3 Page Electrical Data... 4-5 Wiring Diagrams... 6-8 Dimensional Data... 9-10 TXV Selection... 11-12 Installation Instructions... 13-14 Generic Service Parts List... 14 Warranty... 15 Project Information... 15 As Built Service Parts List... BACK 06/01/12

Model Name B = Bally NOMENCLATURE B TL 1 1 5 M A - S1 A Design Version Product Name TL = Two Way Low Profile Evaporator X 100 = Nominal Capacity (10 F TD, ), Btu/H Evap Temp Range M = Medium Temp (10-45 F), 8 FPI. L = Low Temp(-20-0 F), 8 FPI. Unit Electrical Designaton. S1 = 115/1/60 S2 = 208-230/1/60 S6 = 200-220/1/50 Defrost Type. A = Air Defrost E = Electric Defrost STANDARD FEATURES Low height compact size maximizes useable storage space Dual refrigeration coils and two-way air distribution reduces air velocities to minimize product dehydration. Air enters through fan and discharges two ways out of each coil side. Rugged heavy duty motor mount reduces vibration and noise. Electric defrost models include factory installed defrost termination and fan delay thermostat. NSF approved flush to ceiling mount Refrigerants R404A/R507, R22 and R407C. Internally enhanced tube OPTIONAL FEATURES PSC Motors available on all models EC Motors available for Medium Temperature models 038, 060, 077 & 115 and Low Temperature models 033, 052, 066 & 099 B30-BTL-PDI-3-2 - 06/01/12

CAPACITY DATA R404A MEDIUM TEMPERATURE MODELS - CAPACITY * BTL010M BTL015M BTL020M BTL025M BTL032M BTL038M BTL060M BTL077M BTL115M Number of Fans 1 1 1 1 1 1 2 2 3 Capacity * BTUH (watts) Evap Temp F( C) + 20/25 (-3.9/-6.7) 15 (-9.4) 950 (278) 940 (275) 1450 (425) 1430 (419) 2000 (586) 1970 (577) 2500 (733) 2460 (721) 3200 (938) 3150 (923) 3800 (1114) 3740 (1096) 6000 (1758) 5910 (1732) 7700 (2257) 7580 (2221) 11500 (3370) 11330 (3320) 10 (-12.2) 930 (273) 1420 (416) 1960 (574) 2450 (718) 3140 (920) 3720 (1090) 5880 (1723) 7550 (2213) 11270 (3303) Air Flow CFM (L/s) 130 (61.4) 180 (85.0) 237 (112) 270 (127) 440 (208) 440 (208) 928 (438) 807 (381) 1242 (586) Refrigerant Charge R404A Lbs (Kg) 0.4 (0.18) 0.5 (0.23) 0.7 (0.32) 0.8 (0.36) 0.9 (0.41) 1.2 (0.55) 1.4 (0.64) 2.3 (1.05) 3.4 (1.55) LOW TEMPERATURE MODELS - CAPACITY * BTL009L BTL013L BTL017L BTL021L BTL028L BTL033L BTL052L BTL066L BTL099L Number of Fans 1 1 1 1 1 1 2 2 3 Capacity * BTUH (watts) 0 (-17.8) 910 (267) 1340 (393) 1820 (533) 2250 (659) 3000 (879) 3530 (1035) 5560 (1629) 7060 (2069) 10590 (3104) Evap Temp F( C) -10 (-23.3) -15 (-26.1) 880 (258) 870 (255) 1300 (381) 1280 (375) 1770 (519) 1730 (507) 2180 (639) 2140 (627) 2910 (853) 2860 (838) 3430 (1005) 3370 (988) 5410 (1586) 5300 (1553) 6860 (2010) 6730 (1972) 10300 (3019) 10100 (2960) -20 (-28.9) 850 (249) 1250 (366) 1700 (498) 2100 (615) 2800 (821) 3300 (967) 5200 (1524) 6600 (1934) 9900 (2901) Air Flow CFM (L/s) 130 (61.4) 180 (85.0) 237 (112) 270 (127) 440 (208) 440 (208) 928 (438) 807 (381) 1242 (586) Refrigerant Charge R404A Lbs (Kg) 0.4 (0.18) 0.5 (0.23) 0.7 (0.32) 0.8 (0.36) 0.9 (0.41) 1.2 (0.55) 1.4 (0.64) 2.3 (1.05) 3.4 (1.55) Capacities rated using R404A with 10 F (5.6 C) TD & 100 F (38 C) liquid temperature. Capacities at other TD within a range of 8 to 15 F (4.4 to 8.3 C) are directly proportional to TD, or use formula: CAPACITY = (RATED CAPACITY / 10) x TD * Derate capacity by 5% when using EC Motors Correction Factors for Other Refrigerants Use R404A Values Multiplied By: R22 R134a R507 R407C 0.95 0.90 1.00 0.90 When using R407C, the factor above is to be used when matching to condensing units with Dew Point ratings. This factor will ensure that proper system balancing will occur to compensate for glide to fit the application. If the system is sized correctly, one may expect a slight increase in system capacity, along with slightly higher saturated suction temperatures. B30-BTL-PDI-3-3 - 06/01/12

ELECTRICAL DATA 115/1/60 AIR DEFROST MODEL No. of S (S) - SHADED POLE (STANDARD) M.C.A. M.O.P WATTS (S)- PSC (OPTIONAL) M.C.A. M.O.P WATTS (S)- EC (OPTIONAL) M.C.A. M.O.P WATTS BTL010MA-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A BTL015MA-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A BTL020MA-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A BTL025MA-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A BTL032MA-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A BTL038MA-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 0.60 0.75 15 30 BTL060MA-S1A 2 2.4 2.7 15 140 1.30 1.46 15 120 1.20 1.35 15 60 BTL077MA-S1A 2 2.4 2.7 15 140 1.30 1.46 15 120 1.20 1.35 15 60 BTL115MA-S1A 3 3.6 3.9 15 210 1.95 2.11 15 180 1.80 1.95 15 90 ELECTRIC DEFROST MODEL No. of S (S) - SHADED POLE (STANDARD) M.C.A. M.O.P WATTS (S)- PSC (OPTIONAL) M.C.A. M.O.P WATTS (S)- EC (OPTIONAL) M.C.A. M.O.P WATTS WATTS DEFROST HEATERS AMPS M.C.A. M.O.P BTL010ME-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A 206 1.8 2.2 15 BTL015ME-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A 530 4.6 5.8 15 BTL020ME-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A 530 4.6 5.8 15 BTL025ME-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A 530 4.6 5.8 15 BTL032ME-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A 750 6.5 8.2 15 BTL038ME-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 0.60 0.75 15 30 750 6.5 8.2 15 BTL060ME-S1A 2 2.4 2.7 15 140 1.30 1.46 15 120 1.20 1.35 15 60 1100 9.6 12.0 15 BTL077ME-S1A 2 2.4 2.7 15 140 1.30 1.46 15 120 1.20 1.35 15 60 1540 13.4 16.8 20 BTL115ME-S1A 3 3.6 3.9 15 210 1.95 2.11 15 180 1.80 1.95 15 90 2270 19.7 24.6 25 BTL009LE-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A 206 1.8 2.2 15 BTL013LE-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A 530 4.6 5.8 15 BTL017LE-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A 530 4.6 5.8 15 BTL021LE-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A 530 4.6 5.8 15 BTL028LE-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 N/A N/A N/A N/A 750 6.5 8.2 15 BTL033LE-S1A 1 1.2 1.5 15 70 0.65 0.81 15 60 0.60 0.75 15 30 750 6.5 8.2 15 BTL052LE-S1A 2 2.4 2.7 15 140 1.30 1.46 15 120 1.20 1.35 15 60 1100 9.6 12.0 15 BTL066LE-S1A 2 2.4 2.7 15 140 1.30 1.46 15 120 1.20 1.35 15 60 1540 13.4 16.8 20 BTL099LE-S1A 3 3.6 3.9 15 210 1.95 2.11 15 180 1.80 1.95 15 90 2270 19.7 24.6 25 B30-BTL-PDI-3-4 - 06/01/12

ELECTRICAL DATA 208-230/1/60 AIR DEFROST MODEL No. of S (S) - SHADED POLE(STANDARD) M.C.A. M.O.P WATTS (S)- PSC (OPTIONAL) M.C.A. M.O.P WATTS (S)- EC (OPTIONAL) M.C.A. M.O.P WATTS BTL010MA-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 N/A N/A N/A N/A BTL015MA-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 N/A N/A N/A N/A BTL020MA-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 N/A N/A N/A N/A BTL025MA-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 N/A N/A N/A N/A BTL032MA-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 N/A N/A N/A N/A BTL038MA-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 0.30 0.40 15 30 BTL060MA-S2A 2 1.4 1.6 15 120 0.48 0.54 15 100 0.60 0.70 15 60 BTL077MA-S2A 2 1.4 1.6 15 120 0.48 0.54 15 100 0.60 0.70 15 60 BTL115MA-S2A 3 2.1 2.3 15 180 0.72 0.78 15 150 0.90 1.00 15 90 ELECTRIC DEFROST MODEL No. of S (S) - SHADED POLE(STANDARD) M.C.A. M.O.P WATTS (S)- PSC (OPTIONAL) M.C.A. M.O.P WATTS (S)- EC (OPTIONAL) M.C.A. M.O.P WATTS WATTS DEFROST HEATERS AMPS M.C.A. M.O.P BTL010ME-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 - - - - 206 0.9 1.1 15 BTL015ME-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 - - - - 530 2.3 2.9 15 BTL020ME-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 - - - - 530 2.3 2.9 15 BTL025ME-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 - - - - 530 2.3 2.9 15 BTL032ME-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 - - - - 750 3.3 4.1 15 BTL038ME-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 0.30 0.40 15 30 750 3.3 4.1 15 BTL060ME-S2A 2 1.4 1.6 15 120 0.48 0.54 15 100 0.60 0.70 15 60 1100 4.8 6.0 15 BTL077ME-S2A 2 1.4 1.6 15 120 0.48 0.54 15 100 0.60 0.70 15 60 1540 6.7 8.4 15 BTL115ME-S2A 3 2.1 2.3 15 180 0.72 0.78 15 150 0.90 1.00 15 90 2270 9.9 12.4 15 BTL009LE-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 - - - - 206 0.9 1.1 15 BTL013LE-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 - - - - 530 2.3 2.9 15 BTL017LE-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 - - - - 530 2.3 2.9 15 BTL021LE-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 - - - - 530 2.3 2.9 15 BTL028LE-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 - - - - 750 3.3 4.1 15 BTL033LE-S2A 1 0.7 0.9 15 60 0.24 0.30 15 50 0.30 0.40 15 30 750 3.3 4.1 15 BTL052LE-S2A 2 1.4 1.6 15 120 0.48 0.54 15 100 0.60 0.70 15 60 1100 4.8 6.0 15 BTL066LE-S2A 2 1.4 1.6 15 120 0.48 0.54 15 100 0.60 0.70 15 60 1540 6.7 8.4 15 BTL099LE-S2A 3 2.1 2.3 15 180 0.72 0.78 15 150 0.90 1.00 15 90 2270 9.9 12.4 15 B30-BTL-PDI-3-5 - 06/01/12

WIRING DIAGRAM AIR DEFROST - ALL VOLTAGES WITH DEFROST TIME CLOCK WITHOUT DEFROST TIME CLOCK REFER TO NAMEPLATE FOR ELECTRICAL REQUIREMENTS REFER TO NAMEPLATE FOR ELECTRICAL REQUIREMENTS DEFROST CLOCK PARAGON # 8145 OR EQUIVALENT GND L1 L2(N) GND L1 L2(N) GND 1 3 2 TM 4 X N FUSE OR CIRCUIT BREAKER NOTE #3 OMIT 2ND FUSE IF(N) FUSE OR CIRCUIT BREAKER NOTE #3 F 4 OMIT 2ND FUSE IF(N) TO MULTIPLE S (IF APPLIC) F TO MULTIPLE EVAPS 4 (IF APPLIC) PUMP DOWN SWITCH SPACE THERMOSTAT LIQUID LINE SOLENOID VALVE SPACE THERMOSTAT LIQUID LINE SOLENOID VALVE N.C. N.C. GND. 4 F TERMINAL BOARD (SUPPLIED ON MULTIPLE MODELS ONLY) POWER PLUGS GND. 4 F TERMINAL BOARD (SUPPLIED ON MULTIPLE MODELS ONLY) POWER PLUGS REFER TO DATA PLATE FOR QUANTITY REFER TO DATA PLATE FOR QUANTITY NOTES 1-TL AD 03/08 1). USE COPPER CONDUCTORS ONLY 2). USE 75 C WIRE (OR HIGHER) 3). OVERCURRENT PROTECTION FOR S AND DEFROST HEATERS MUST NOT EXCEED MAXIMUM VALUE SHOWN ON NAMEPLATE. 4). MAY BE FACTORY INSTALLED-MOUNTED AND WIRED ON. TERMINALS -COMPONENT TERMINAL -TERMINAL BLOCK TERMINAL CONDUCTORS/WIRING FACTORY WIRING WIRING BY OTHERS OPTIONAL FACTORY OR BY OTHERS ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. B30-BTL-PDI-3-6 - 06/01/12

WIRING DIAGRAM ELECTRIC DEFROST - 115V FOR ALL MODELS WITHOUT DEFROST HEATER CONTACTOR USING MAXIMUM 15A HEATER OVERCURRENT PROTECTION FOR ALL MODELS USING DEFROST HEATER CONTACTOR DEFROST CLOCK PARAGON # 8145 OR EQUIVALENT TM 3 4 1 2 N X REFER TO NAMEPLATE FOR ELECTRICAL REQUIREMENTS 15A GND FUSE OR CIRCUIT BREAKER L1 N DEFROST CLOCK PARAGON # 8145 OR EQUIVALENT TM 3 4 X 1 2 FUSE OR CIRCUIT BREAKER (IF APPLIC.) N NOTE #3 REFER TO NAMEPLATE FOR ELECTRICAL REQUIREMENTS GND L1 N FUSE OR CIRCUIT BREAKER NOTE #3 COMPR INTERLOCK COMPR INTERLOCK C L1 T1 L2 T2 DEFROST HEATER CONTACTOR SPACE THERMOSTAT N.C. SPACE THERMOSTAT N.C. PUMP DOWN SWITCH LIQUID LINE SOL VALVE PUMP DOWN SWITCH LIQUID LINE SOL VALVE 1 ORANGE JUMPER ORANGE JUMPER SEE NOTE: GND. 4 F ORANGE X N 3 H1 H2 H3 JUMPER BN TERMINAL BOARD RD DT (SUPPLIED ON MULTIPLE MODELS ONLY) C FD R.H. COIL BOTTOM GND. 4 F X BN DT FD RD C N 3 TERMINAL BOARD (SUPPLIED ON MULTIPLE MODELS ONLY) ORANGE JUMPER H1 R.H. COIL BOTTOM H2 H3 DEFROST TERMINATION & DELAY CONTROL (10.0A MAX.) DT-DEFROST TERM FD- DELAY L.H. COIL BOTTOM DEFROST HEATERS DEFROST TERMINATION & DELAY CONTROL (10.0A MAX.) DT-DEFROST TERM FD- DELAY L.H. COIL BOTTOM DEFROST HEATERS POWER PLUGS REFER TO DATA PLATE FOR QUANTITY POWER PLUGS REFER TO DATA PLATE FOR QUANTITY WARNING EVAP FIELD MODIFICATION MUST BE MADE SEE NOTE: 1 REMOVE ORANGE JUMPER FROM H2 TO N NOTES 1). USE COPPER CONDUCTORS ONLY 2). USE 75 C WIRE (OR HIGHER) 3). OVERCURRENT PROTECTION FOR S AND DEFROST HEATERS MUST NOT EXCEED MAXIMUM VALUE SHOWN ON NAMEPLATE. 4.) MAY BE FACTORY INSTALLED-MOUNTED AND WIRED ON TERMINALS -COMPONENT TERMINAL -TERMINAL BLOCK TERMINAL CONDUCTORS/WIRING FACTORY WIRING WIRING BY OTHERS OPTIONAL FACTORY OR BY OTHERS ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 2-TL ED1 03/08 B30-BTL-PDI-3-7 - 06/01/12

FOR ALL MODELS WITHOUT DEFROST HEATER CONTACTOR USING MAXIMUM 15A HEATER OVERCURRENT PROTECTION WIRING DIAGRAM ELECTRIC DEFROST - 230V FOR ALL MODELS USING DEFROST HEATER CONTACTOR DEFROST CLOCK PARAGON # 8145 OR EQUIVALENT 1 3 2 TM 4 X N REFER TO NAMEPLATE FOR ELECTRICAL REQUIREMENTS L1 L2 GND 15A FUSE OR CIRCUIT BREAKER DEFROST CLOCK PARAGON # 8145 OR EQUIVALENT TM 3 4 X 1 2 N FUSE OR CIRCUIT BREAKER (IF APPLIC.) NOTE #3 REFER TO NAMEPLATE FOR ELECTRICAL REQUIREMENTS GND L1 L2 FUSE OR CIRCUIT BREAKER NOTE #3 COMPR INTERLOCK COMPR INTERLOCK C L1 T1 L2 T2 DEFROST HEATER CONTACTOR PUMP DOWN SWITCH SPACE THERMOSTAT N.C. LIQUID LINE SOL VALVE PUMP DOWN SWITCH SPACE THERMOSTAT N.C. LIQUID LINE SOL VALVE 1 ORANGE JUMPER SEE NOTE: ORANGE JUMPER GND. 4 F ORANGE X N 3 H1 H2 H3 JUMPER BN TERMINAL BOARD RD DT (SUPPLIED ON MULTIPLE MODELS ONLY) R.H. COIL C BOTTOM FD DEFROST TERMINATION L.H. COIL & DELAY BOTTOM CONTROL (10.0A MAX.) DEFROST HEATERS DT-DEFROST TERM FD- DELAY GND. 4 F X BN DT FD DEFROST TERMINATION & DELAY CONTROL (10.0A MAX.) DT-DEFROST TERM FD- DELAY RD C N 3 TERMINAL BOARD (SUPPLIED ON MULTIPLE MODELS ONLY) ORANGE JUMPER H1 H2 R.H. COIL BOTTOM L.H. COIL BOTTOM DEFROST HEATERS H3 POWER PLUGS REFER TO DATA PLATE FOR QUANTITY POWER PLUGS REFER TO DATA PLATE FOR QUANTITY WARNING SEE NOTE: EVAP FIELD MODIFICATION 1 MUST BE MADE REMOVE ORANGE JUMPER FROM H2 TO N NOTES TERMINALS 1). USE COPPER CONDUCTORS ONLY 2). USE 75 C WIRE (OR HIGHER) 3). OVERCURRENT PROTECTION FOR S AND DEFROST HEATERS MUST NOT EXCEED MAXIMUM VALUE SHOWN ON NAMEPLATE. 4.) MAY BE FACTORY INSTALLED-MOUNTED AND WIRED ON -COMPONENT TERMINAL -TERMINAL BLOCK TERMINAL CONDUCTORS/WIRING FACTORY WIRING WIRING BY OTHERS OPTIONAL FACTORY OR BY OTHERS ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES. 3-TL ED2 03/08 B30-BTL-PDI-3-8 - 06/01/12

DIMENSIONAL DATA - 1 Inches (mm) PIPING CONNECTION CONNECTION END VIEW 7/8 (22 mm) dia. knockouts 2 connection end SIDE VIEW B AIR OUT AIR OUT 9/16 (14 mm) dia. knockouts 2 each side 7/8 (22 mm) dia. knockouts 2 each side AIR IN A BOTTOM VIEW 1/2 (12 mm) dia. aluminum drain. C 3" (76 mm) Defrost control Splice box. electric defrost models NOTE: Dimensional views shown with electric defrost heaters splice box and defrost control mounted. E 1-3/8" (35 mm) TXV Connection D Suction Connection 9/16" (14 mm) 4 Mounting holes 7/32 (6 mm) dia. MODEL Suc. Conn. TXV A B C D E APPROX. WEIGHT (ID) Sweat Inlet Size Inches mm Inches mm Inches mm Inches mm Inches mm Lbs. Kgs BTL 010M* 3/8 1/2 Flare 18 7/8 479 4 1/2 114 14 1/8 359 17 3/4 451 9 3/4 248 11.6 5.3 BTL 015M* 3/8 1/2 Flare 18 7/8 479 4 1/2 114 14 1/8 359 17 3/4 451 9 3/4 248 12.6 5.7 BTL 020M* 3/8 1/2 Flare 18 7/8 479 5 1/2 140 14 1/8 359 17 3/4 451 9 3/4 248 13.7 6.2 BTL 025M* 3/8 1/2 Flare 18 7/8 479 5 1/2 140 14 1/8 359 17 3/4 451 9 3/4 248 14.7 6.7 BTL 032M* 3/8 1/2 ODS 21 7/8 556 5 1/2 140 19 1/8 486 20 3/4 527 14 3/4 375 18.9 8.6 BTL 038M* 3/8 1/2 ODS 21 7/8 556 5 1/2 140 19 1/8 486 20 3/4 527 14 3/4 375 20.0 9.1 BTL 009LE 3/8 1/2 Flare 18 7/8 479 4 1/2 114 14 1/8 359 17 3/4 451 9 3/4 248 11.6 5.3 BTL 013LE 3/8 1/2 Flare 18 7/8 479 4 1/2 114 14 1/8 359 17 3/4 451 9 3/4 248 12.6 5.7 BTL 017LE 3/8 1/2 ODS 18 7/8 479 5 1/2 140 14 1/8 359 17 3/4 451 9 3/4 248 13.7 6.2 BTL 021LE 3/8 1/2 ODS 18 7/8 479 5 1/2 140 14 1/8 359 17 3/4 451 9 3/4 248 14.7 6.7 BTL 028LE 1/2 1/2 ODS 21 7/8 556 5 1/2 140 19 1/8 486 20 3/4 527 14 3/4 375 18.9 8.6 BTL 033LE 1/2 1/2 ODS 21 7/8 556 5 1/2 140 19 1/8 486 20 3/4 527 14 3/4 375 20.0 9.1 * - A (AIR DEFROST) OR E (ELECTRIC DEFROST) B30-BTL-PDI-3-9 - 06/01/12

DIMENSIONAL DATA - 2 & 3 Inches (mm) PIPING CONNECTION END VIEW AIR OUT AIR OUT NOTES: 1). Electric defrost views shown. Air defrost models have identical dimensioning. AIR IN 23-3/4 (603) 2). Electrical connection end is opposite the piping end on multiple fan models. 9/16 (14 mm) dia knockouts 2 each side 7/8 (22 mm) dia knockouts 2 each side SIDE VIEW 7/8 (22 mm) dia knockouts 1 each side 7-5/8 (194) 1-1/8 (28 mm) dia knockouts 1 each side AIR C AIR 1" FPT. Aluminum drain fitting. 5/16 (9 mm) Mounting holes. BOTTOM VIEW TXV Connection 1/2"(13) ODS. Electrical compartment 22-1/4 (565) 23-5/8 (600) 3 3 E D F MODEL Suc. Conn. TXV C D E F APPROX. WEIGHT (ID) Sweat Inlet Size Inches mm Inches mm Inches mm Inches mm Lbs. Kgs BTL 060M 1/2 1/2 ODS 42 3/4 1086 4 holes @ 8 203 7 11/16 195 10 15/16 278 37.8 17.1 BTL 077M 5/8 1/2 ODS 42 3/4 1086 4 holes @ 8 203 7 11/16 195 10 15/16 278 39.9 18.1 BTL 115M 5/8 1/2 ODS 59 1/2 1511 6 holes @ 8 203 8 203 11 7/16 291 59.9 27.2 BTL 052LE 5/8 1/2 ODS 42 3/4 1086 4 holes @ 8 203 7 11/16 195 10 15/16 278 37.8 17.1 BTL 066LE 5/8 1/2 ODS 42 3/4 1086 4 holes @ 8 203 7 11/16 195 10 15/16 278 39.9 18.1 BTL 099LE 7/8 1/2 ODS 59 1/2 1511 6 holes @ 8 203 8 203 11 7/16 291 59.9 27.2 B30-BTL-PDI-3-10 - 06/01/12

NOZZLE SELECTIONS Nozzle Selections (Factory installed) For all applications and refrigerants Model Nozzle BTL010MA/ME NA BTL015MA/ME NA BTL020MA/ME NA BTL025MA/ME NA BTL032MA/ME L-1/4 BTL038MA/ME L-1/3 BTL060MA/ME L-1/2 BTL077MA/ME L-3/4 BTL115MA/ME L-1 Model Nozzle BTL009LE NA BTL013LE NA BTL017LE L-1/4 BTL021LE L-1/3 BTL028LE L-1/2 BTL033LE L-1/2 BTL052LE L-1 BTL066LE L-1 BTL099LE L-1 1/2 SPORLAN MODEL BTL010M ALCO MEDIUM TEMP - EXPANSION VALVE SELECTION For medium temp. R-507, refrigerant designation changes from S to P. MODEL BTL010M BTL015M BTL020M BTL025M BTL032M BTL038M BTL060M BTL077M BTL115M TD CAPACITY @ 25 F SST 10 950 15 1,425 10 1,450 15 2,175 TD CAPACITY @ 25 F SST ALL TXV Selections based on 90-100 F liquid. R404A R507 GS-1/8-C R404A R507 R22 R407C GV-1/5-C BTL015M GS-1/8-C GV-1/5-C BTL020M 10 2,000 GS-1/8-C 15 3,000 GS-1/6-C GV-1/5-C BTL025M 10 2,500 GV-1/5-C GS-1/6-C 15 3,750 GV-1/3-C BTL032M 10 3,200 EGSE-1/4-C EGVE-1/3-C 15 4,800 EGSE-1/2-C EGVE-1/2-C BTL038M 10 3,800 EGSE-1/4-C EGVE-1/3-C BTL060M BTL077M BTL115M 15 5,700 EGSE-1/2-C EGVE-1/2-C 10 6,000 EGSE-1/2-C 15 9,000 EGSE-1-C EGVE-3/4-C 10 7,700 EGSE-1/2-C EGVE-3/4-C 15 11,550 EGSE-1-C EGVE-1-C 10 11,500 EGSE-1-C EGVE-1-C 15 17,250 EGSE-1 1/2-C EGVE-1 1/2-C R22 R407C 10 950 15 1,425 HF-1/8-SC HF-1/4-HC 10 1,450 15 2,175 HF-1/8-SC HF-1/4-HC 10 2,000 HF-1/8-SC 15 3,000 HF-1/4-SC HF-1/4-HC 10 2,500 15 3,750 HF-1/4-SC HF-1/4-HC 10 3,200 HFESC-1/4-SC HFESC-1/4-HC 15 4,800 HFESC-1/2-SC HFESC-1/2-HC 10 3,800 HFESC-1/4-SC 15 5,700 HFESC-1/2-SC HFESC-1/2-HC 10 6,000 HFESC-1/2-SC HFESC-1/2-HC 15 9,000 HFESC-1-SC HFESC-1-HC 10 7,700 HFESC-1/2-SC 15 11,550 HFESC-1-SC HFESC-1-HC 10 11,500 HFESC-1-SC HFESC-1-HC 15 17,250 HFESC-1 1/4-SC HFESC-1 1/2-HC DANFOSS MODEL TD CAPACITY @ 25 F SST BTL010M BTL015M BTL020M BTL025M BTL032M BTL038M BTL060M BTL077M BTL115M R404A R507 R22 R407C 10 950 TUA-R404A-0-N 15 1,425 TUA-R404A-1-N TUA-R22-0-N 10 1,450 TUA-R404A-1-N TUA-R22-0-N 15 2,175 TUA-R404A-2-N TUA-R22-1-N 10 2,000 TUA-R404A-2-N TUA-R22-1-N 15 3,000 TUAE-R404A-3-N TUAE-R22-2-N 10 2,500 TUA-R404A-2-N TUA-R22-1-N 15 3,750 TUAE-R404A-3-N TUAE-R22-2-N 10 3,200 TUAE-R404A-3-N TUAE-R22-2-N 15 4,800 TUAE-R404A-4-N TUAE-R22-3-N 10 3,800 TUAE-R404A-3-N TUAE-R22-3-N 15 5,700 TUAE-R404A-4-N TUAE-R22-4-N 10 6,000 TUAE-R404A-5-N TUAE-R22-4-N 15 9,000 TUAE-R404A-6-N TUAE-R22-5-N 10 7,700 TUAE-R404A-5-N TUAE-R22-5-N 15 11,550 TUAE-R404A-6-N TUAE-R22-6-N 10 11,500 TUAE-R404A-6-N TUAE-R22-6-N 15 17,250 TUAE-R404A-8-N TUAE-R22-7-N B30-BTL-PDI-3-11 - 06/01/12

SPORLAN EVAP TEMP. F EVAP TEMP. F R404A R507 ALCO LOW TEMP R404A R507 EXPANSION VALVE SELECTIONS For medium temp. R-507, refrigerant designation changes from S to P. For R404A/R507 valves operating below 0F, the pressure limiting charge ZP may be substituted for the Z charge. EVAP TEMP. F EVAP TEMP. F R404A R507 BTL009L BTL013L BTL017L BTL021L BTL028L BTUH VALVE # BTUH VALVE # BTUH VALVE # BTUH VALVE # BTUH VALVE # 0 910 GS-1/8-C 1,340 GS-1/8-C 1,820 EGSE-1/8-C 2,250 EGSE-1/6-C 3,000 EGSE-1/4-C -10 880 1,300 1,770 2,180 2,910-15 870 GS-1/8-Z 1,280 GS-1/8-Z 1,730 EGSE-1/6-Z 2,140 EGSE-1/6-Z 2,860-20 850 1,250 1,700 2,100 2,800 BTL033L BTL052L BTL066L BTL099L BTUH VALVE # BTUH VALVE BTUH VALVE # BTUH VALVE # 0 3,530 EGSE-1/4-C 5,560 EGSE-1/2-C 7,060 EGSE-1/2-C 10,590 EGSE-1-C -10 3,430 5,410 6,860 10,300-15 3,370 EGSE-1/4-Z 5,300 EGSE-1/2-Z 6,730 EGSE-1-Z 10,100-20 3,300 5,200 6,600 9,900 EGSE-1-Z BTL009L BTL013L BTL017L BTL021L BTL028L EGSE-1/4-Z BTUH VALVE # BTUH VALVE # BTUH VALVE # BTUH VALVE # BTUH VALVE # 0 910 HF-1/8-SC 1,340 HF-1/8-SC 1,820 HFESC-1/8-SC 2,250 HFESC-1/8-SC 3,000 HFESC-1/4-SC -10 880 1,300 1,770 2,180 2,910-15 870 HF-1/8-SW45 1,280 HF-1/8-SW45 1,730 HFESC-1/4-SW45 2,140 HFESC-1/4-SW45 2,860-20 850 1,250 1,700 2,100 2,800 BTL033L BTL052L BTL066L BTL099L BTUH VALVE # BTUH VALVE # BTUH VALVE # BTUH VALVE # 0 3,530 HFESC-1/4-SC 5,560 HFESC-1/2-SC 7,060 HFESC-1/2-SC 10,590 HFESC-1-SC -10 3,430 5,410 6,860 10,300-15 3,370 HFESC-1/2-SW45 5,300 HFESC-1/2-SW45 6,730 HFESC-1-SW45 10,100 HFESC-1 1/4-SW45-20 3,300 5,200 6,600 9,900 HFESC-1/4-SW45 For medium temp. R-507, refrigerant designation changes from S to P. DANFOSS EVAP TEMP. F EVAP TEMP. F R404A R507 All TXV Selections based on 90-100 F liquid. BTL009L BTL013L BTL017L BTL021L BTL028L BTUH VALVE # BTUH VALVE # BTUH VALVE # BTUH VALVE # BTUH VALVE # 0 910 TUA-R404A-0-N 1,340 TUA-R404A-1-N 1,820 TUAE-R404A-2-N 2,250 TUA-R404A-3-N 3,000 TUAE-R404A-4-N -10 880 1,300 1,770 2,180 2,910-15 870 TUA-R404A-0-NM 1,280 TUA-R404A-2-NM 1,730 TUAE-R404A-3-NM 2,140 TUAE-R404A-4-NM 2,860-20 850 1,250 1,700 2,100 2,800 BTL033L BTL052L BTL066L BTL099L BTUH VALVE # BTUH VALVE # BTUH VALVE # BTUH VALVE # 0 3,530 TUAE-R404A-4-N 5,560 TUAE-R404A-5-N 7,060 TUAE-R404A-6-N 10,590 TUAE-R404A-7-N -10 3,430 5,410 6,860 10,300-15 3,370 TUAE-R404A-5-NM 5,300 TUAE-R404A-6-NM 6,730 TUAE-R404A-7-NM 10,100 TUAE-R404A-8-NM -20 3,300 5,200 6,600 9,900 TUAE-R404A-5-NM B30-BTL-PDI-3-12 - 06/01/12

INSPECTION Careful inspection of all parts when received for loss or damage in transit is very important - Remember, you, the consignee, must make any claim necessary against the transportation company. Shipping damage or missing parts, when discovered at the outset, will prevent later unnecessary and costly delays. Electrical characteristics should also be checked at this time to ensure that they are as ordered. APPLICATION Two-Way evaporators are designed for use in coolers and freezers such as reach in boxes, display cases, back bars, walk-in rooms and any other cooler applications where a low velocity, uniform air flow is required. The compact and low height unit provides maximum useable product storage space. At room temperatures above 34 F (1.1 o C) and evaporating temperatures no lower than 27 F (-2.8 C) the air flowing through the coil will accomplish the defrost (Air Defrost). At room temperatures 34 o F and below (to -10 o F) positive defrosting is required (Electric defrost). These will require the use of : 1. Time Clock (to initiate and terminate the defrost cycle), 2. Defrost termination thermostat (to prevent unnecessary prolonged heating and steaming of the coil once all the frost and ice has melted). And if a freezer, 3. Fan delay thermostat (to prevent evaporator fans starting up right away and blowing water on to the fan blades, guards and floor). This evaporator coil must not be exposed to any abnormal environments (acidic or caustic) that can result in coil corrosion and leaks. Consult factory for optional baked on phenolic protective coatings. These evaporators are for use primarily on R22 and R404A refrigerants and their approved alternatives / replacements. INSTALLATION The installation and start up of evaporators should only be performed by qualified refrigeration mechanics. This equipment should be installed in accordance with all applicable codes, ordinances, and local by-laws. INSTALLATION INSTRUCTIONS LOCATION The evaporator is designed to be mounted to the ceiling of the box or cabinet. Refrigeration piping and electrical connections are routed to the rear sides (through the knock-outs). The unit must be mounted to a level ceiling to ensure complete drainage from the condensate pan to the drain fitting. Refer to the dimensional drawings for the drain fitting and mounting location details. On freezer applications it is important that warm, humid infiltrated air is not drawn directly towards the evaporator. Keeping the evaporator away from the door, using strip curtains, and using door switches to lock out and de-energize the liquid solenoid valve are all effective methods to minimize any unnecessary frost build -up of the fan guard. (Air enters the fan and discharges out each side of the coil). TXV SELECTION (thermostatic expansion valve) For normal operating conditions refer to the TXV selection chart. When selecting valves ensure they are sized to meet the capacity at the actual evaporating temperature, liquid temperature and operating TD of the system. All these conditions can greatly affect the size and selection. Consult the factory or valve manufacturer for assistance. All models that use a distributor (larger models) must use a nozzle. Smaller models do not have distributors or nozzles. The TXV superheat setting should NOT be initially adjusted. After the room has reached or is close to the required operating temperature the TXV superheat should then be checked and only adjusted if necessary. Refer to Section on SYSTEM CHECK. To avoid overheating the valve or distributor wrap a wet cloth around the valve diaphragm and body. MOUNTING Mounting brackets with 7/32-5/16 diameter holes are provided for flush mounting to the ceiling. Ensure the evaporator is located correctly with the air flowing in the two desired directions. Avoid discharging the air directly on to glass doors or door openings. After mounting the coil check the slope of the drain pan with a level. If the ceiling is not level the drain pan slope may not be correct which can result in defrosting (ice-up) problems. B30-BTL-PDI-3-13 - 06/01/12

INSTALLATION INSTRUCTIONS (CONT D) DRAIN LINE The drain line should be run from the drain connection, sloping at least 4 vertical drop for every foot of horizontal distance. A trap outside the room will allow proper draining throughout the line. Connection should be made to proper drainage facilities that comply with local codes and regulations. In freezers, to prevent drain line freeze up problems, the line must be heated and insulated. A heat input of 20 W per foot in a 0 F room and 30 W per foot in a -20 F room is usually satisfactory. Once the line has been completed, double check the slope in the drain pan to ensure proper drainage (prevention of ice build-up on pan). PIPING Refrigerant line sizes are important and are not necessarily the same size as the connections at the condensing unit or evaporator. If in doubt refer to a recognized source. (Manufacturer s Engineering Manual, Ashrae Manuals, etc.) WIRING Wire system in accordance with local codes and regulations. A 36 cord is provided for single fan air defrost models (AD). Multiple fans have a junction terminal box for conduit connections. GENERIC SERVICE PARTS LIST When fan delay thermostats are installed the fans may not start up until the coil temperature reaches approximately 26 F. On initial start up it may be necessary to bypass (jumper) this control temporarily until the coil is cold enough. SYSTEM CHECK Before Start Up: 1. Ensure wiring is in accordance with codes. 2. Refrigerant lines are properly sized and routed. 3. Thorough leak check, evacuation and dehydration has been performed. 4. Drain line has been checked for free flow. After Start Up: 1. Fan has been checked for correct air flow and no obstructions. 2. Expansion valve superheat has been checked for proper operation. (Superheat of the coil should be around 5 to 6 F for a 10 F TD.) MAINTENANCE The unit should be periodically inspected for any dirt or build up on the fin surface and cleaned if necessary with a soft whisk or brush. The fan motor is permanently lubricated and should not require service. MODEL NUMBER MEDIUM TEMP LOW TEMP GUARD SHADED POLE S PSC S EC S 115/1/60 208-230/1/60 BLADE 115/1/60 208-230/1/60 BLADE 115/1/60 208-230/1/60 BLADE BTL010M BTL009L 1043293 1088581 1088582 1043870-001 1088583 1088584 1043870-002 N/A N/A N/A BTL015M BTL013L 1043293 1088581 1088582 1043870-002 1088583 1088584 1043870-002 N/A N/A N/A BTL020M BTL017L 1043293 1088581 1088582 1043870-003 1088583 1088584 1043870-003 N/A N/A N/A BTL025M BTL021L 1043293 1088581 1088582 1043870-004 1088583 1088584 1043870-004 N/A N/A N/A BTL032M BTL028L 1043294 1088581 1088582 1043870-005 1088583 1088584 1043870-005 N/A N/A N/A BTL038M BTL033L 1043294 1088581 1088582 1043870-005 1088583 1088584 1043870-005 1091721 1091722 1043870-005 BTL060M BTL052L 1043294 1088581 1088582 1043870-005 1088583 1088584 1043870-005 1091721 1091722 1043870-005 BTL077M BTL066L 1043294 1088581 1088582 1043870-005 1088583 1088584 1043870-005 1091721 1091722 1043870-005 BTL115M BTL099L 1043294 1088581 1088582 1043870-006 1088583 1088584 1043870-006 1091721 1091722 1043870-006 MODEL NUMBER DEFROST HEATERS* TERMINAL BOARD DRAIN PAN (ME & LE ASSEMBLY ELECTRIC MEDIUM TEMP LOW TEMP models only) AIR DEFROST DEFROST * All heaters are rated at 115V - either wired in series (for 230V) or parallel (for 115V) ELECTRIC DEFROST DELAY / DEFROST TERMINATION CONTROL BTL010M BTL009L 1070468-001 1043868-001 N/A N/A 1043725 BTL015M BTL013L 1069861-001 1043868-001 N/A N/A 1043725 BTL020M BTL017L 1069861-001 1043868-001 N/A N/A 1043725 BTL025M BTL021L 1069861-001 1043868-001 N/A N/A 1043725 BTL032M BTL028L 1069861-002 1043869-001 N/A N/A 1043725 BTL038M BTL033L 1069861-002 1043869-001 N/A N/A 1043725 BTL060M BTL052L 1070468-002 1070010-001 1048825 1070060 1043725 BTL077M BTL066L 1069861-003 1070010-001 1048825 1070060 1043725 BTL115M BTL099L 1069861-004 1070011-001 1048825 1070060 1043725 B30-BTL-PDI-3-14 - 06/01/12

Finished Goods Warranty The terms and conditions as described below in the General Warranty Policy cover all products manufactured by National Refrigeration. GENERAL WARRANTY POLICY Subject to the terms and conditions hereof, the Company warrants all Products, including Service Parts, manufactured by the Company to be free of defects in material or workmanship, under normal use and application for a period of one (1) year from the original date of installation, or eighteen (18) months from the date of shipment from the Company, whichever occurs first. Any replacement part(s) so supplied will be warranted for the balance of the product s original warranty. The part(s) to be replaced must be made available in exchange for the replacement part(s) and reasonable proof of the original installation date of the product must be presented in order to establish the effective date of the warranty, failing which, the effective date will be based upon the date of manufacture plus thirty (30) days. Any labour, material, refrigerant, transportation, freight or other charges incurred in connection with the performance of this warranty will be the responsibility of the owner at the current rates and prices then in effect. This warranty may be transferred to a subsequent owner of the product. THIS WARRANTY DOES NOT COVER (a) Damages caused by accident, abuse, negligence, misuse, riot, fire, flood, or Acts of God (b) damages caused by operating the product in a corrosive atmosphere (c) damages caused by any unauthorized alteration or repair of the system affecting the product s reliability or performance (d) damages caused by improper matching or application of the product or the product s components (e) damages caused by failing to provide routine and proper maintenance or service to the product (f) expenses incurred for the erecting, disconnecting, or dismantling the product (g) parts used in connection with normal maintenance, such as filters or belts (h) products no longer at the site of the original installation (i) products installed or operated other than in accordance with the printed instructions, with the local installation or building codes and with good trade practices (j) products lost or stolen. No one is authorized to change this WARRANTY or to create for or on behalf of the Company any other obligation or liability in connection with the Product(s). There is no other representation, warranty or condition in any respect, expressed or implied, made by or binding upon the Company other than the above or as provided by provincial or state law and which cannot be limited or excluded by such law, nor will we be liable in any way for incidental, consequential, or special damages however caused. The provisions of this additional written warranty are in addition to and not a modification of or subtraction from the statutory warranties and other rights and remedies provided by Federal, Provincial or State laws. System PROJECT INFORMATION Model Number Date of Start-Up Serial Number Service Contractor B30-BTL-PDI-3-15 - 06/01/12

AS BUILT SERVICE PARTS LIST Service Parts List Label To Be Attached HERE DISTRIBUTED BY: General Sales, Parts & Service Manufacturing & Engineering 135 Little Nine Drive, Morehead City, NC 28557 252-240-2829 1-800-24-BALLY FAX: 252-240-0384 e-mail: ballysales@ballyrefboxes.com www.ballyrefboxes.com Due to Manufacturer s policy of continuous product improvement, the Manufacturer reserves the right to make changes without notice. 06/01/12