: PRT / PRT PRT / PRT-N1

Similar documents
Model : PRT-EN Model: PRT-EN1

Underfloor Heating Programmable Thermostat

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

Model: PRT-TS / PRT-NTS

Model: Slimline-N. 1 Slimline Series

Model: Slimline-B. Battery Series

Model: Slimline-RF. 1 Slimline Series

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

PRT-TS WiFi PRT-TS WiFi

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

Model: Available in : Sapphire Black and Glacier White. 1 Series

Model: Touch-RF. 1 Wireless Series

Model: Available in: Sapphire Black and Glacier White. 1 Series

Model: Touch-RS. 1 Touch-RS

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

Operating Instructions Model: PRT/HW - PRT/HW-N Version 3. 09/09 Revision 2 Ref: PRT/HW/NV3

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Operating Instructions

Operating Instructions Model : HC HC-N

Model: Edge-HC. 1 edge-hc

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

Uponor Comfort-E Thermostat Dig. Prog Set T-86 INSTALLATION AND OPERATION MANUAL

CS027 User Instructions

Drayton Digistat +3RF

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

Model: RT510RF. Installation Manual

C-Stat 17-ZW User Instructions

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

AUTO CM CM USER GUIDE

Digital Room Thermostat

Model: RT310. Installation Manual

ThermoPlus AS2-RF & ASR-RF Installation Instructions

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

Battery Powered Electronic Programmable Room Thermostat

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

User Manual THR870CUK Programmable Thermostat

Model: RT310RF. Installation Manual

RT021 User and Installation Instructions

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

MAKING MODERN LIVING POSSIBLE RET2000 B/M/MS. Electronic digital thermostat with LCD User Guide. Danfoss Heating

Elegance. SMT-700 User manual. Ver

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

User Guide Y9420H Sundial RF 2 Pack 2

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

irad Wireless Controller

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

User Guide for EHE & EHE Programmable Room Thermostat

Evolution Control. Zone Control Homeowner s Guide

3 Channel Multi-Purpose Programmer User Instructions

User Manual THR872CUK Wireless Programmable Thermostat

Digital Electronic Thermostat With RF

ES3247B. 3 Channel Programmer. User and Installation Instructions

ESRTD3. Digital Room Thermostat with TPI & Delayed Start. User and Installation Instructions

4 in 1 Digital Thermostat Control

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

RF Programmable Room Thermostat User Instructions

Vokèra OpenTherm 711 with external sensor connected

- Data Brochure tekmarnet 4 Thermostat 542e

Cat No. 099A. Digital Programmable Thermostat for Weekday/Weekend Setting. User Maunal

ESRTD2 Electronic Room Thermostat, with LCD Display

5245 / Thermotouch 4.3dC. Dual Control Thermostat. Installation & User Guide

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

ELECTRONIC THERMOSTAT

Battery Powered Electronic Room Thermostat Cat. No. TRT033

Vokèra OpenTherm 711 without external sensor connected

Infinity Control. Homeowner s Guide. The New Feeling of Comfort

User Manual THR842DUK Wireless Digital Thermostat

SC Installation, Operation & Application Guide

Owner s Manual MODEL 8555

SAS6000UTK-7 UNIVERSAL THERMOSTAT

TB8220U Commercial Programmable Thermostat OWNER S GUIDE

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

Programmable Thermostat

Digital Thermostat Models: VS30W and VS30B

CoziStat. 1. Introduction and Brief Description COZISTAT INSTALLATION I NSTRUCTIONS &OPERATING MANUAL

Slimline Curve Electric Radiator. Step by Step Programming Guide

User s Manual

1F Non-Programmable 5/1/1 Day 7 Day

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Smart Temp. Model

Owner s Manual. Part Number 33CSCPACHP-01

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

ETN-24-SUPER-PROG (US Program - Celsius)

The Visage & Elegance Range of Electric Radiators INSTALLATION & OPERATING INSTRUCTIONS

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

INFRARED PANEL HEATER

YEAR-ROUND COMFORT EVOLUTION CONTROL ZONE CONTROL HOMEOWNER S GUIDE. The Ultimate Home Comfort System.

Panel Convector Heater User Instructions

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

RF Programmable Room Thermostat Installation Instructions

Transcription:

Model: PRT / PRT-N Model: PRT / PRT-N 1

Model: PRT / PRT-N Table of Contents Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure LCD Display Setting the Clock Temperature Display Setting the Comfort Levels Locking the Thermostat Setting the Temperature Temperature Hold Holiday Programming Frost Protection Power On / Off Optional Features Re-calibrating the Thermostat Factory Reset Wiring Diagrams 1 2 3-4 5-6 7-8 9 10 11-12 13 14 15 16 17 18 19-22 23 24 25-29 21 Slimline Series Model: PRT / PRT-N 2

What is a Programmable Room Thermostat? A programmable room thermostat is both a programmer and a room thermostat. The programmer allows you to set On and Off periods to suit your own lifestyle. The room thermostat works by sensing the air temperature, switching on the heating when the air temperature falls below the thermostat setting, and switching it off once this set temperature has been reached. So a programmable room thermostat lets you choose what times you want the heating to be on, and what temperature it should reach while it is on. It will allow you to select different temperatures in your home at different times of the day (and days of the week) to meet your particular needs and preferences. Setting a programmable room thermostat to a higher temperature will not make the room heat up any faster. How quickly the room heats up depends on the design & size of the heating system. Similarly reducing the temperature setting does not affect how quickly the room cools down. Setting a programmable room thermostat to a lower temperature will result in the room being controlled at a lower temperature, and saves energy. The way to set and use your programmable room thermostat is to find the lowest temperature settings that you are comfortable with at the different times you have chosen, and then leave it alone to do its job. The best way to do this is to set the room thermostat to a low temperature say 18 C, and then turn it up by 1 C each day until you are comfortable with the temperature. You won t have to adjust the thermostat further. Any adjustment above this setting will waste energy and cost you more money. If your heating system is a boiler with radiators, there will usually be only one programmable room thermostat to control the whole house. But you can have different temperatures in individual rooms by installing thermostatic radiator valves (TRVs) on individual radiators. If you don t have TRVs, you should choose a temperature that is reasonable for the whole house. If you do have TRVs, you can choose a slightly higher setting to make sure that even the coldest room is comfortable, then prevent any overheating in other rooms by adjusting the TRVs. You are able to temporarily adjust the heating program by overriding or using the temperature hold feature. These features are explained further on pages 14 and 15 of this manual. Programmable room thermostats need a free flow of air to sense the temperature, so they must not be covered by curtains or blocked by furniture. Nearby electric fires, televisions, wall or table lamps may also prevent the thermostat from working properly. 3 Slimline Series Model: PRT / PRT-N 4

Installation Procedure Do Mount the thermostat at eye level. Read the instructions fully so you get the best from our product. Don t Do not install near to a direct heat source as this will affect functionality. Do not push hard on the LCD screen as this may cause irreparable damage. 1 2 This Slimline Series thermostat is designed to be flush mounted and requires a back box of 35mm (minimum depth) to be sunk into the wall prior to installation. Step 1 Carefully separate the front half of the thermostat from the back plate by placing a small flat head terminal driver into the slots on the bottom face of the thermostat. Step 2 Place the thermostat front somewhere safe. Terminate the thermostat as shown in the diagrams on pages 25-29 of this booklet. Step 3 Screw the thermostat back plate securely into the back box. Step 4 Clip the front of the thermostat back onto the thermostat back plate. 3 4 5 Slimline Series Model: PRT / PRT-N 6

1 2 3 4 5 LCD Display 12 1. Room Temp - Indicates the current temperature sensor mode. 2. Day Indicator - Displays the current day. 3. Frost Icon - Displayed when the thermostat is in frost protection mode. 4. Flame Icon - Displayed when the thermostat is calling for heat, the flame icon will flash when the optimum start function is in operation. 5. Temperature Hold - When a Temp Hold is active, HOLD FOR and the remaining time period is displayed. 6. Set - Indicates when changes are being made to programs or temperature set points. 7. Holiday Indicator - Displayed when the thermostat is in holiday mode. 8. Current Temp - Indicates the current sensor temperature. 9. Program Cycle Indicator - Displayed during programming only to show which period is being altered. 10. Keypad Lock Indicator - Displayed when the keypad is locked. 11. Units of Temperature - Degrees Celsius or Fahrenheit. 12. Clock - Digital clock display in 24h format. 6 7 8 9 10 11 7 Slimline Series Model: PRT / PRT-N 8

Setting the Clock To set the clock, follow these steps. With the thermostat turned ON, press the Clock key twice... Use the Up/Down keys to set the hours... Press H to confirm settings... Use the Up/Down keys to set the minutes... Press H to confirm settings... Use the Up/Down keys to set the day of the week... Press A to confirm settings and return to main display... Temperature Display The temperature display information is driven by two different inputs; the sensor measurement and the target temperature you have set. Room Temperature Set Temperature Day Hours Minutes This is the current room temperature. This is the temperature you are trying to achieve in your home. 9 Slimline Series Model: PRT / PRT-N 10

Comfort Levels Explained The thermostat provides Weekday/Weekend or 7 Day Programming options. You should consult the Optional Features section to select the required mode. The thermostat is supplied with comfort levels already programmed, but these can be changed easily. The default times and temperatures are; 08.00-21 C (Wake) 09.30-16 C (Leave) 16.30-22 C (Return) 23.00-17 C (Sleep) If you only want to use 2 levels, you should program the unused levels to --.-- Note: For Weekday/Weekend programming, the 4 comfort levels are the same for all weekdays but can be different for the weekends. For 7 Day programming, each day can have 4 different comfort levels. To program comfort levels, press Clock once... Use the Up/Down keys to enter the required WAKE time... Press H to confirm settings... Use the Up/Down keys to enter the required WAKE temperature... Press H to confirm settings... You will now see LEAVE displayed on screen. Repeat the programming steps for each period until complete. For unused periods enter --.-- and the thermostat will ignore the setting. Press A to confirm settings and return to main display... Note: In 7 Day programming mode you can repeat for each day independently. In Weekday/Weekend programming mode you will see Sat Sun displayed on screen and can repeat for the weekend. To change the programming mode please refer to pages 20-22. For Weekday/Weekend programming, Mon Tue Wed Thu Fri are displayed on screen. For 7 Day programming, only Mon is displayed in the day indicator field. 11 Slimline Series Model: PRT / PRT-N 12

Locking the Thermostat The thermostat has a keypad lock facility. To activate the lock follow these steps. Press and hold the A and Down keys together for 10 seconds... You will see the lock symbol appear on screen... To unlock, repeat the steps above until the lock symbol disappears. Note: The keypad lock indicator is only displayed when the lock is active. Temperature Control The Up/Down keys allow you to adjust the set temperature... When you press either key, you will see the word SET and the desired temperature will be displayed on screen. Use the Up/Down keys to adjust the SET value... Press A to confirm settings and return to main display... Note: This override will be maintained until the next programmed comfort level. Set Temperature Keypad Lock Indicator Set Icon 13 Slimline Series Model: PRT / PRT-N 14

Temperature Hold The temperature hold function allows you to manually override the current operating program and set a different temperature for a desired period. Press H to commence temperature hold... Use the Up/Down keys to enter the required hold time... Press H to confirm settings... Use the Up/Down keys to enter the required hold temperature... Press A to confirm settings and return to main display... You will see the Hold For indication is displayed on screen. The time will countdown the set duration and then revert to the normal program. Holiday The holiday function reduces the set temperature in your home to the frost protection temperature setting (see page 19). The thermostat will maintain this temperature for the duration of the holiday and will then automatically return to the program mode on your return. Press H three times (until you see the suitcase on screen)... Use the Up/Down keys to enter the number of days holiday... Press A to confirm settings and return to main display... The display will show a suitcase indicating the thermostat is in holiday mode. Note: A holiday period does not start until 00:00 the next day. For example, if you set a holiday period on Friday for 2 days, Saturday will be counted as the first day and the thermostat will revert back to the programmed schedule at 00:00 on Monday. Hold ON Indicator Hold Time Remaining Holiday Days Holiday ON Indicator To cancel temperature hold, follow the same steps but reduce the Hold time to 00:00 hours. To cancel, follow the same steps but reduce the Holiday duration to 00 days. 15 Slimline Series Model: PRT / PRT-N 16

Frost Mode Pressing the Power button once will place the thermostat in frost protect mode. In this mode, the thermostat will display the frost icon and will only turn the heating on should the room temperature drop below the set frost temperature (see page 19). Should the heating be turned on whilst in frost mode, the flame icon will be displayed. To cancel the frost protect mode, press the Power button once again. Heating On/Off The heating is indicated ON when the flame icon is displayed. When the flame icon is absent, there is no requirement for heating to achieve the set temperature but the thermostat remains active. To turn the thermostat OFF completely, press and hold the Power button... The display and heating output will be turned OFF completely.* To turn the thermostat back ON, press the Power button once again... Thermostat completely OFF Thermostat powered ON Frost Protection Mode Enabled *See Feature 3 on page 19 17 Slimline Series Model: PRT / PRT-N 18

Optional Features Explained THE FOLLOWING SETTINGS ARE OPTIONAL AND IN MOST CASES NEED NOT BE ADJUSTED Feature 01 - Temperature Format: This function allows you to select between C and F. Feature 02 Switching Differential: This function allows you to increase the switching differential of the thermostat. The default is 1 C which means that with a set temperature of 20 C, the thermostat will switch the heating on at 19 C and off at 20 C. With a 2 C differential, the heating will switch on at 18 C and off at 20 C. Feature 03 Frost Protect: You can set whether the thermostat will maintain the frost temperature when the thermostat display is turned off. As a default, this is enabled. Feature 04 Frost Protect Temperature: This is the temperature maintained when the thermostat is in frost mode. The range is 07-17 C. The default is 12 C and is suitable for most applications. Feature 05 Output Delay: To prevent rapid switching, an output delay can be entered. This can be set from 00-15 minutes. The default is 00 which means there is no delay. Feature 06 Communication Address: This setting is used when you have connected your thermostat to a network system. Each thermostat on your network must have a unique communication address. This can be set from 01-32. Feature 07 Temperature Up/Down Limit: This function allows you to limit the use of the Up and Down keys. This limit is also applicable when the thermostat is locked and so allows you to give others limited control over the heating system. Feature 08 Sensor Selection: This thermostat has a built in air sensor. Feature 09 Floor Temp Limit: This function is not available on this model. Feature 10 Optimum Start: Optimum start will delay the start up of the heating system to the latest possible moment to avoid unnecessary heating and ensure the building is warm at the programmed time. The thermostat uses the rate of change information to calculate how long the heating needs to raise the building temperature 1 C (with a rate of change of 20, the thermostat has calculated the heating needs 20 minutes to raise the building temperature 1 C) and starts the heating accordingly. Feature 11 Rate Of Change: This is the number of minutes the thermostat has calculated it takes to raise your building temperature 1 C. The thermostat will continue to monitor and learn the heat up time of your home to optimise heating efficiency. Feature 12 - Programming Mode: The thermostat offers 2 programming methods. Weekday/Weekend allows you to program 4 comfort levels for the weekdays and 4 different comfort levels for the weekend. In 7 Day program mode, each day has 4 comfort levels that can be programmed independently. 19 Slimline Series Model: PRT / PRT-N 20

Adjusting the Optional Settings Optional Settings - Feature Table To adjust the optional settings, follow these steps. FEATURE DESCRIPTION SETTING Press and hold the Power button to turn the thermostat OFF... 01 Temperature Format 00 = o C, 01 = o F ( C = Default) Press and hold the Clock key until the display appears as shown below... 02 03 Switching Differential Frost Mode 01 o - 03 o C (01 o C = Default) 00 = Enabled, 01 = Disabled (00 = Default) 04 Frost Protection Temperature 07 o - 17 o C (12 o C = Default) Setting Value Feature Number 05 06 07 Output Delay Communications ID No. Up/Down Temperature Limit 00-15 Minutes (00 = Default) Set unique comms address 01-32 00 o - 10 o C (00 = Default) 08 Sensor Selection Built in Air Sensor 09 Floor Temperature Limit Not used on this model 10 Optimum Start 00-03 Hours (00 = Default) Use the Clock key to cycle through the features... Use the Up/Down keys to change the setting... Press A to confirm settings... 11 12 Rate of Change Program Mode Minutes to raise by 1 o C 00 = Weekday/Weekend 01 = 7 Day Programming (00 = Default) Press the Power button once again to turn the thermostat back ON... 21 Slimline Series Model: PRT / PRT-N 22

Re-calibrating the Thermostat If you need to re-calibrate the thermostat, follow these steps. Press and hold the Power button to turn the thermostat OFF... Press and hold BOTH the Power and Down keys together until the temperature appears on the screen... Use the Up/Down keys to configure the new temperature... Press A to confirm settings... Press the Power button once to turn the thermostat back ON... Factory Reset The thermostat has a reset function to restore all settings to their factory defaults. To perform a factory reset, follow these steps. Press and hold the Power button to turn the thermostat OFF... Press and hold the Power and Up keys together until the LCD powers up. All of the icons will be displayed on screen... When the icons have disappeared from the screen, the thermostat has been successfully reset. Press the Power button once to turn the thermostat back ON... All icons displayed simultaneously. Factory reset is complete. Calibration Temperature Setting Set Icon 23 Slimline Series Model: PRT / PRT-N 24

Wiring Diagram - PRT to Boiler S/L Wiring Diagram - PRT to Boiler Voltfree THIS UNIT MUST BE PROTECTED BY A FUSE OR RCD THIS UNIT MUST BE PROTECTED BY A FUSE OR RCD PRT 230V AC 50/60Hz PRT 230V AC 50/60Hz 230VAC SWITCHED LIVE TO BOILER A2 A1 230VAC N L TO CONNECT BOILER CONSULT BOILER MAKERS DIAGRAM LIVE 230V SUPPLY IN NEUTRAL LR VOLT FREE TO BOILER LS A2 A1 LS & LR ARE NORMALLY THE ROOM THERMOSTAT CONNECTIONS N L TO CONNECT BOILER CONSULT BOILER MAKERS DIAGRAM LIVE 230V SUPPLY IN NEUTRAL 25 Slimline Series Model: PRT / PRT-N 26

Wiring Diagram - PRT to Valve Wiring Diagram - PRT-N to PRC Volt Free Switching THIS UNIT MUST BE PROTECTED BY A FUSE OR RCD PRT 230V AC 50/60Hz PRT-N 12VDC Network Y B RT2 RT1 - A2 A1 + Recommendations Max Cable Size - 1.5MM Back Box Depth - 35MM Max Load - 3 Amps A2 A1 230VAC N L TO CONNECT BOILER CONSULT BOILER MAKERS DIAGRAM COMMS CABLE LS TO BOILER LR L N NEUTRAL LIVE 230V SUPPLY IN NEUTRAL 12V _ + A2 B2 POWERED RELAY CARD For 230V switched live output, link mains L to C L E N C NC NO C NC NO HEATING VALVE LS & LR ARE NORMALLY THE ROOM THERMOSTAT CONNECTIONS 230V SUPPLY IN Volt Free Output 27 Slimline Series Model: PRT / PRT-N 28

Wiring Diagram - PRT-N to UH1 Notes COMMS CABLE Network PRT-N 12VDC Y B RT2 RT1 - A2 A1 + + _ A1 A2 ZONE X Y B UH1 + _ A1 A2 ZONE X Y Connecting PRT-N to the UH1 The UH1 allows connection of up to eight 12 volt network thermostats. When connecting network thermostats to the UH1 use CAT5-FTP or BELDEN 9538. Connect the screen to Earth at the UH1. B 29 Slimline Series Model: PRT / PRT-N 30

Want More Information? Heating Professionals: Request a copy of our product installation guide containing detailed technical specifications for our complete product range: www.heatmiser.com/guide Call our support team on: +44 (0)1254 669090 Or view technical specifications directly on our website: www.heatmiser.com Twitter: heatmiseruk PDF FAQ Video 31 Slimline Series Facebook: facebook.com/thermostats