ET4 heat/cool day RF programmable room thermostat. ET4 Receiver

Similar documents
L. Terminal block Connecting Label:

Cat No. 099A. Digital Programmable Thermostat for Weekday/Weekend Setting. User Maunal

ARATON 2100 TX 1 AURATON 2100 TX. Advanced Remote Control Programmable Thermostat

T105 Advanced Remote Control Programmable Thermostat. User Manual

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

AURATON 2005 / 2005 TX

Model: Slimline-RF. 1 Slimline Series

Smart Temp. Model

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Digital Electronic Thermostat With RF

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Digital Electronic Thermostat With RF

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

INITIALIZATION / INSTALLATION

SAS908WHB-3-RF/B WIRELESS THERMOSTAT

Installation & User s Instructions

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

Model: Touch-RF. 1 Wireless Series

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Operation and Maintenance Manual OM 897-3

Easy-Stat. Wireless Programmable Room Thermostat Pt No

Programmable Thermostat

irad Wireless Controller

Emerson Blue Easy Set 1H/1C

Owner s Manual. Part Number 33CS250-RC

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

OWNER S MANUAL. Part Number P RF

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

CT2800 Programmable Thermostat

CET B-RF Wireless Electronic Hot Water Cylinder Thermostat User & Installation Instructions

INSTALLATION MANUAL. Need Help? This manual covers the following models: T725. Power Type. Thermostat Applications Guide. Page.

OPERATING MANUAL. Need Help? This manual covers: T955WH Wireless Thermostat System. Table of Contents

Model: Slimline-B. Battery Series

MagicStat CT3300 Programmable Thermostat

Programmable Electronic Thermostat

Model: Available in : Sapphire Black and Glacier White. 1 Series

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

VisionPRO Series with RedLINK. User Guide

OPERATING MANUAL. Need Help? This manual covers the following models: T755. Table of Contents

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Model: RT310RF. Installation Manual

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

Operation GT7000. Time / Current Temp. TEMP UP button. Display. Fan. Switch. Set Temp. Display. Mode Switch. Backlight. TEMP DOWN button.

Climatouch /CT03TS/217S31 Programmable Universal Touch Screen thermostat

Safety & Installation Instructions

: PRT / PRT PRT / PRT-N1

ThermoPlus AS2-RF & ASR-RF Installation Instructions

OPERATING MANUAL. This manual covers TopTech models: TT-S-755

Please read this manual carefully before installation and use.

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

High Precision Digital Rain Gauge with Indoor Temperature and Humidity

OPERATING MANUAL. Need Help? This manual covers the following models: T915. Table of Contents

T-32-TS Touchscreen Thermostat. Installation Manual

CentaurPlus ZW and HRT4-ZW

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

OPERATING MANUAL. Need Help? This manual covers the following models: T805. Table of Contents

Drayton Digistat +3RF

INSTALLATION MANUAL. Need Help? This manual covers the following models: T915. Power Type. Thermostat Applications Guide. Page.

stock code 5265 FIXING GUIDE Thermonet underfloor heating programmable thermostat kit

Instruction FH-CWP Thermostat

WM3000 WIRELESS MODULES

Digital Room Thermostat

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Model: Available in: Sapphire Black and Glacier White. 1 Series

WIRELESS COLOR FORECAST STATION

User Guide for EHE & EHE Programmable Room Thermostat

INSTRUCTION MANUAL TRC-1490 Wireless Indoor and Outdoor Weather Station

Operating Manual. Series Touchscreen Programmable Demand Control Thermostat. UtilityPRO TM

OPERATING MANUAL. Need Help? This manual covers the following models: T715. Table of Contents

Comfort System T-21-P Touchscreen Thermostat Installation Manual

WIRELESS RAIN GAUGE WITH IN/OUT TEMPERATURE INSTRUCTION MANUAL

TB8220U Commercial Programmable Thermostat OWNER S GUIDE

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

OPERATING MANUAL. This manual covers TopTech models: TT-S-855 and T855

ETN-24-HC21-PROG Econo-Vent

Underfloor Heating Programmable Thermostat

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

TH232-AF-230 Installation Instructions

Smart Temp. ApolloP/n Installation Manual. Version 1.0

OPERATING MANUAL. This manual covers TopTech models: TT-S-755H

Wireless Color Weather Station

Product Manual SZ1009

Operator: Save these instructions for future use!

Model: Touch-RS. 1 Touch-RS

USER'S OPERATING INSTRUCTIONS

GreenCon On/Off Room Thermostat

Wireless Thermostat (WTS10) Keypad Operation Guide

Model: Quick Setup Guide DC: Atomic Projection Alarm Clock. Projection Lens. Buttons. Snooze/Backlight

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

C-Stat 17-ZW User Instructions

Caution: To maintain compliance with the RF exposure guidelines, place the unit at least 20cm from nearby persons.

Digital Programmable

Model: Edge-HC. 1 edge-hc

Model: WS-8147U-IT Instruction Manual DC: ATOMIC DIGITAL CLOCK WITH MOON PHASE

Transcription:

TFC GROUP LLP Programmable RF Room Thermostat ET4 ET4 heat/cool 5+1+1 day RF programmable room thermostat 1 N 2 ET4 Receiver L L Supply Live N Supply Neutral 1 Live Return 2 Live Feed 20V AC 50Hz 24 240V AC 50Hz Specifications: Frequency band: 4 MHZ Range: Up to 0 Mtrs within buildings Control range: 5 Deg C to 5 Deg C (41 Deg to 95 Deg F) Accuracy: 0.5 Deg C Receiver - Input Voltage: 240VAC 50HZ Receiver - Output Voltage: 24..240VAC 50HZ 10()A Max Working Temperature: 0 Deg C to 50 Deg C Colour: White Dimensions: Control Centre 82mm 88mm 25mm, Receiver 82mm 82mm 65mm

ET4 TFC Group LLP, Tower House, Vale Rise, Tonbridge, Kent TN9 1TB http://www.tfc-group.co.uk RF Thermostat INSTRUCTION MANUAL TABLE OF CONTENTS A. Installation and Mounting 1, Installation 2, Wiring, Mounting B, Start/Reset C, Normal Operation D, Setting Clock E, Factory Defined Programs F, Setting Own Program G, Override Settings H, Temporary / Permanent Override Functions I, Power Off / Standby Function J, Jumper Options K,Jumper Locations L,Communication Set-up (pairing) M,Specifications N,Terminal Connecting Block Label 1 Page 4 4 6 6 7 8 9/10/11 11/12 12 1 14/15 18 18 19 20 ET4 RF Programmable Thermostat 1, The system includes one wireless thermostat controller (Tx) plus one RF receiver (Rx). 2, Transmits up to 20 meters indoors., Communicates at 4.92MHz(USA/European Standard) and is designed for unlicensed operation under FCC Part 15. Warning: 1, There may be a dead zone in the RF communication. That means the receiver may not be able to receive the message from the transmitter. Before the installation, check the communication first. If the communication fails, relocate the wireless thermostat. 2, If there is interference in communication, Follow the set-up procedure to change the coding between the RF thermostat and receiver., It is recommended that the RF thermostat and Receiver are mounted at least 2 meters from electrical devices such as, radio, TV, PC etc. Do not mount the RF thermostat or receiver on metal wall boxes as this will interfere with the RF signal and reduce the range. 2 A, Installation & Mounting: Caution: Turn off the ET4 and any electrical devices that are to be connected after installation. The installation must be carried out by a qualified electrician and conform to current IEE regulations. 1, Installation Location: The thermostat (Transmitter) should be mounted on an inner wall 1.5m above the floor in a position where it is readily affected by changes in the ambient room temperature. Prevent direct exposure sunlight and moisture. Do not place this unit where air circulation is low, or where it is susceptible to rapid temperature changes (e.g. near a door or window). Do not position near heating/cooling appliances. 2, Wiring: There are four terminals on the receiver. L, N, 1 & 2. Volt free connection: If connecting to a volt free system 220-240 VAC should be connected to L & N and the switched pair into terminals 1 & 2. If the circuit has a send and return, the send should be connected to terminal 2 and the return to terminal 1. Mains switching: Connect 220-240 VAC to L & N, Link Live (L) to terminal 2. Terminal 1 gives a 20V AC switched live output when heating is in demand. Refer to the circuit diagram printed on rating label on the back of the product. Push all wiring into wall prior to mounting to avoid trapping wires. The thermostat should be protected by a fuse with a current rating no larger than 10A., Mounting: Mount the ET4 Thermostat using the screw accessories provided through slots/holes on rear face of the unit. Mount the receiver into back-box provided. 4 Transmitter Battery Installation / Replacement: Caution: Turn off electrical devices and disconnect the supply to any connected appliances before installing or replacing batteries. Replace only with the same (AAA Alkaline) or equivalent batteries. Do not dispose of used batteries with household waste. Refer to your local area for correct disposal method. ET4 Installation 1, Pull out the battery draw. 2, Place new batteries taking note of orientation of +/- on battery drawer., Dispose old batteries properly. 4, Slide battery draw into position. 5, Check operation and press reset (RST) if not functioning correctly. 5 (Figure 1) B, Start/Reset: 1, After wiring and mounting, switch off all connected devices. Place 2 new AAA 1.5V alkaline batteries ensuring correct orientation of battery polarity. LCD display will show. 2, Press RST to reset. The ET4 is now ready to control the heater/cooler., Switch on the heater/cooler. The heater/cooler will remain off until the ET4 activates the output, with or displayed depending on configuration for a heating or cooling application. C, Normal Time Mode: 1, Temperature detection starts and LCD displays the room temperature. 2, If the battery is low, will be flashing. If has been flashing for 48 hours and the batteries have not been replaced, the ET4 will stop measuring the room temperature and the LCD will go blank. The ET4 will turn off the output and the heater/cooler will cease to operate. The system will only function once the discharged batteries are removed and new batteries are fitted. 6

, In heating mode frost protection is activated automatically if the ambient temperature falls below 5 0 C. Will show in the display and the output will be forced ON for heating or OFF if the ET4 is configured for cooling. 4, If the ambient temperature is below 0 0 C, LO will show in the display. 5, Above 40 0 C, HI will show in the display. D. Setting the real-time clock: 1, Press, the day of week (1-7) will flash 1=Monday. Press, To select the current day of the week. 2, Press, the hour will flash, press, to set the hour., Press, the minute will flash, press, to set the minute. 4, Pressing will return back to step 1 (day setting). 5, Press to confirm settings and return to the default screen. E, Factory Defined Programs: The heater/cooler turns on according to the activated program and the control temperature setting. When the heater/cooler is ON, the program number and or will appear in the display. The pre-defined programs are as below: Cooler mode: Note: If no buttons are pressed within 10 seconds the ET4 will return to the default screen 7 8 Heater mode: F, Setting Your Own Program: Mon to Fri, Sat and Sun are divided into six periods P1 to P6. The time set for each period is the start time for that period. To set your own program you should set the period start time and the temperature to be achieved during that period. e.g. In the table above P1 starts at 6am Monday and will hold the temperature at 21 0 C until period 2 (P2) starts at 8am, when the temperature will be lowered to 16 0 C until period (P) & the temperature 9 will raise to 21 0 C until period 4 (P4). P4 will hold the temperature at 16 0 C and so on. You can edit the preset times/temperature values by following the steps below. 1, Press, the hour will flash, Press, to change the hour setting. 2, Press, the minute will flash, Press, to change the minute setting., Press, the temperature will flash, Press, to change the temperature set-point. Repeat this sequence for P2, P, P4, P5 & P6 (Mon-Fri) 4, Press, the hour will flash for P1 day 6 (Saturday), Press, to change the hour setting. 5, Press, the minute will flash, Press, to change the minute setting. 6, Press, the temperature will flash, Press, to change the temperature set-point. Repeat this sequence for P2, P, P4, P5 & P6 (Saturday) 10 7, Press, the hour will flash for P1 day 7 (Sunday), Press, to change the hour setting. 8, Press, the minute will flash, Press, to change the minute setting. 9, Press, the temperature will flash, Press, to change the temperature set-point. Repeat this sequence for P2, P, P4, P5 & P6 (Sunday) 10, Press to confirm changes and return to default screen. Selecting Temporary or Permanent Override Mode: 1, Press to change the mode from normal to Temporary Override. The icon will be displayed. 2, Press again and the mode changes from Temporary to Permanent Override mode. Icon will be displayed., Press once more and the mode changes from Permanent Override back to normal timed operation. Review and adjust the Override temperature: 1, With the ET4 in Temporary or Permanent override, press or to display the Override temperature. 2, Press or for 2 seconds, the Override temperature will flash., Release or and then use or to adjust the Override temperature. 4, Press to exit Override temperature setting. The ET4 will return to the default screen if no buttons are pressed after 10 seconds. G, Temporary Override mode: The Temporary Override mode is maintained until the start of the next timed period. Permanent Override mode: The room temperature will be maintained at the Override temperature set-point until the Override mode is released. 11 12 Releasing Override mode: 1, When the ET4 is in Temporary Override Press twice to return to normal timed operation. 2, When the ET4 is in Permanent Override Press once to return to normal timed operation. H, Control Off / Sleep Mode: 1, Press to select the sleep mode and control off mode. The sequence is as below: Normal mode Sleep mode Control Off mode Normal mode. 2, Press any other button to exit the Control Off / Sleep mode and return to normal operation. Sleep Mode: When the ET4 is in sleep mode the icon is displayed. The ET4 stops measuring and controlling the temperature. The heater/cooler is turned off, irrespective of the current setting temperature. Control Off mode: When the ET4 is in Sleep mode and icon is displayed, pressing will put the ET4 into Control Off mode. The LCD display and the heater / cooler are turned off, irrespective of the current control temperature setting. I, Jumper Selection: Delay / No Delay Jumper Heater Cooler No Delay 10sec 4mins Delay 4mins 4mins Choose the Delay option if compressor heat is connected. a = 12/24 hours b = Delay / No delay c = Heater / Cooler 12-hour / 24-hour mode jumper: When the 12-hour option is selected, the time is shown in 12 hour mode. Otherwise the time is displayed in-24 hour mode. Heater / Cooler Jumper: The ET4 can be set for a heating or cooling configuration via internal jumper. 1 14

J, Jumper Selection: Delay / No Delay Jumper: Heater Cooler No Delay 10sec 4mins Delay 4mins 4mins Choose the delay option if compressor heat is connected. Heater/Cooler Jumper: Select the heater option (default) when a heater is connected to the receiver. Select the Cooler option when using the ET4 for a cooling application, fan cooling etc. Press reset (RST) after modifying jumper selections. K, Jumper Locations: 1 2 15 16 L, Comms Address Setting: Inside the transmitter and receiver there is a bank of 9 dip switches for setting a unique address (pairing). The receiver will ignore communications from transmitters set to a different address. To access the dip switches it is necessary to open the thermostat and remove the front cover from the receiver by removing the two crosshead screws on the rear cover. Default jumper settings: - No Delay - 24hr clock - Heating Receiver (Rx) dip switches Transmitter (Tx) dip 17 18 The dip switches on both units must be set identically to communicate. M, Specification: N, Terminal Connecting Block Label: 1, Temperature Measurement: 0 0 C - 4 0 C (0.1 0 C/step) 2, Accuracy: ± 0.5 0 C, Temperature Control Range: 5 0 C - 5 0 C (0.5 0 C/step) 4, Terminals: 2.5mm 2 Cable 5, Electronic Control: Type 2.B action 6, Transmitter Batteries: 2 x 1.5V AAA Alkaline batteries 7, Receiver Input Voltage: 240V AC 8, Receiver Output Voltage: 24..240V AC 50/60Hz 10()A Max 9, Operating Temperature: 0 0 C - 50 0 C 10, Storage Temperature: 0 0 C - 60 0 C 11, Sensing Element: NTC Thermistor 19 20