QUANTITY EQUIPMENT MANUFACTURER MODEL NUMBER SERIAL NUMBER

Similar documents
Sequence of Operations (excerpt)

PITTSBURG STATE UNIVERSITY. HVAC and BUILDING AUTOMATION SYSTEM STANDARDS

Single zone RTU, controlled by a programmable thermostat. Single zone RTU, generic description, with power exhauster

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

AHU Air Handling Unit Fundamentals. j.ilangumaran

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Technical Assignment 3 11/15/04. Executive Summary

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

REPLACEMENT PARTS LIST

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

November 11, City of Sparks 215 S. 21 st St. Sparks, NV

Exhibit II Equipment Lists & Sample Service Sheet

FLORIDA A&M UNIVERSITY PERFORMANCE CONTRACT SCOPE OF WORK

Energy Efficiency Through Waste Heat Recovery. Heat Recovery Centrifugal Chillers and Templifier Water Heaters

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

MrHVAC.com, Inc. Duct Cleaning

.2 Section Waste Management and Disposal.

DX-9100 Applications from Engineering Services

Introduction to HVAC. American Standard Inc Air Conditioning Clinic TRG-TRC018-EN

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Description of All Alternatives Considered-

High Efficiency Heating and Cooling Systems for Community Colleges Kirk Mescher, PE, LEED AP Principal ICCCFO

McQuay BACnet Solution: Microtech II Self-contained Unit Controller with Discharge Air Control (DAC)

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

11/2 ORT THREEE. Virtua Repla. acement Hospi. ital. Voorhees NJ. Justin Prior. Mechanical

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

SA Series Start up Report

HVAC CONTROLS INTRODUCTION

Power and Energy Management Solutions

FEATURES AND BENEFITS

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

EarthWise System Seminar

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

NEW CHILLER SCHEDULE

Multi-Path RTU-TYPE 2

Field Start-Up Sheet Direct Fired Gas Equipment

York 25-Ton VAV Rooftop Unit

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

Appendix B. Symbols for Drawings. Table B.1. Air moving devices and ductwork symbols. Air Movement. Fans. Axial flow fan.

Gas-Fired Indoor and Outdoor Duct Furnaces

CP CP

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

CONTENTS. B. System Design and Performance Requirements

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

4. OVERVIEW OF MECHANICAL SYSTEM

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018

Andrea Borowski The Pennsylvania State University University Park, PA November 11, 2002 Consultant: Dr. Bahnfleth Technical Assignment M-3

"This is only the scope of work for the project. For more information, interested parties should contact Procurement at

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION REFRIGERATION

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Engineered for flexibility and performance

Modular Supply Make-Up Air Unit

COHASSET, MA March 6, The following is the HVAC outline specifications, which defines the scope of work of the HVAC system.

DDC POINT LIST. 004 Harry Griffith Hall. RFP #PW17-2 Exhibit J Page 1 of 9 AHU 1 BOILER BOX DUAL DUCT MIXING. Building: HUMBOLDT STATE UNIVERSITY

APPA Institute for Facilities Management. Energy & Utilities Cooling Production (316) Purpose of Today s Presentation. Agenda

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

DESIGN GUIDELINES SECTION HVAC

Agenda and Objectives

Smart ways to save energy IntelliCon INSTALLATION MANUAL

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

General Catalogue. FORM SSI - G.C (94)

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Air Cooled Scroll Compressor Condensing Unit

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION CONDITIONS FACILITIES MASTER PLAN MAY

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Energy Recovery with Cooling and Heating Model ERCH

MECHANICAL SERVICES 101. Ian White

Installation, Operation and Maintenance Instructions

College of Technological Studies Department of Power & Refrigeration Technology. Course Contents

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

GARCIA GALUSKA DESOUSA Consulting Engineers

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

FieldServer Driver - Serial FS McQuay Microtech Open Protocol

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

FAARM-Underground Facility. Conceptual Design Review. Mechanical Systems. Dunham Associates, Inc.

REPLACEMENT PARTS LIST

REQUEST FOR PROPOSALS FOR THE PROVISION OF PREVENTIVE MAINTENANCE ON FACILITY HVAC SYSTEMS FOR SKOKIE PUBLIC LIBRARY

Life Cycle Cost Of Selecting Chiller Equipment: Manufacturer s Viewpoint. Daryl Showalter ChillerApplications Manager McQuay International

21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device

50TM TFF COMBINATION HEATING/COOLING UNITS

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Technical Development Program

50TM COMBINATION HEATING/COOLING UNITS

2009 IECC Commercial Mechanical Requirements

COMMERCIAL AIR HANDLER

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

Digital Inverter 4 series 8 & 10HP

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners Up to 11.3 EER

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Virginia Tech Standards for Building Automation System

DCG Commercial. Submittal Data Form

Transcription:

Kentucky State Penitentiary All equipment listed below shall be the responsibility of the vendor to perform preventive maint All model/control numbers are correct to the best of all knowledge. QUANTITY EQUIPMENT MANUFACTURER MODEL NUMBER SERIAL NUMBER Dry Storage Condensing Unit TEZA060H8-HT3B-F 152106234 Evaporators TPLP532MAS2BR6 159254093 TPLP532MAS2BR6 152304446 Condensing Unit CZT055M6C T11B15355 Evaporators LSC260BK T11E10518 LSC260BK T11E10519 Condensing Unit TESA050H8-HT3B-B 122401935 Evaporators TMP245ME-S2A 122210912 1 & 2 CELLHOUSE MECHANICAL EQUIPMENT 1 CHILLER McQuay 30hs-160 1 h.w.cir pumps 25 variable vol.boxes 1 stand by pump 1 c.w.pump 2 Air Handlers TEMPERATURE CONTROLS 4 damper mot pos. HONEYWELL MP918A1024 4 damper mot pos. HONEYWELL MP909H1331 4 duct smoke detector HONEYWELL TC805B1010 4 inlet vane actuator HONEYWELL MP920B1002 28 space istat HONEYWELL TP970A1004 4 duct temp controller HONEYWELL LP920A1021 4 duct temp sensor HONEYWELL LP914A1003 2 duct temp controller HONEYWELL LP920B1029 1 temp con HONEYWELL T675A1565 2 freeze stat HONEYWELL L480G1044 4 humidity sensors HONEYWELL HP971A1024 2 static pre sensors HONEYWELL PP905B1006 1 reheat 2-way HONEYWELL VP531A1012 2 reheat 2-way HONEYWELL VP531A1038 5 reheat 2-way HONEYWELL VP531A1053 2 3-way preheat HONEYWELL V5013B1003 1 h.w. conv. HONEYWELL V5011C2258 1 h.w. conv. HONEYWELL V5011C2258 1 dhw conv HONEYWELL V5011C2217 JCI metasys Control Circuit HEATING HOT WATER CONVERTER CONTROLS 1 high limit HONEYWELL LP920B1011 1 temperature sensor HONEYWELL LP914A1052 1 temperature sensor HONEYWELL LP914A1011 1 air compressor Devibiss DEVPPE6G2C0D 1 dryer Hankison HKN8210B 3 CELLHOUSE Page 1 of 12

1 GreenHeck Smoke Evac System 1 TRANE packaged air cooled chiller 5 TRANE air handling units 1 chilled water circulating pump 5 TC-5131 low limit stats 3 smoke detector L-302/L-306 2 smoke detector L-302/L-307 5 outdoor aire stats TC-4111 5 damper actuators MS-8405 10 sensors TS-8405 3 valve VA-8313-201-4-8 2 valve VA-9313-301-4-10 3 valve VS92-13247-4-6 2 valve VS-9213-351-410 5 6 stage controller CP-8261-702 4 CELLHOUSE 1 Air Handler Unit McQuay 1 reciprecating compressor McQuay 2 temp gauges BRK L342 2 electric acutator Barber-Coleman MA-405 1 electric acutator Barber-Coleman MP-470 1 electric acutator Barber-Coleman MP-475 1 duct istat Barber-Coleman TA-3432 1 duct istat Barber-Coleman TC-4111 1 duct istat Barber-Coleman TC-5141 1 controller Barber-Coleman THC-2 1 electronic sensor Barber-Coleman TS-8405 1 transformer Barber-Coleman AE-174 1 transformer Barber-Coleman AE-202 2 well Barber-Coleman AT-8155 1 electronic control Barber-Coleman CP-3161-212 2 time closk Barber-Coleman P-301 1 relay Barber-Coleman P125-2-3 1 socket Barber-Coleman P-100-6 3 relay Barber-Coleman P0127-2-4 3 socket Barber-Coleman P-100-4 1 electric actuator Barber-Coleman MA-418 1 electronic sensing Barber-Coleman TS-8405 1 valve Barber-Coleman VS-9253-211-4-8 1 valve Barber-Coleman VS-9253-312-4-11 8 toggle switch Barber-Coleman CYZP-11 2 relay Barber-Coleman P-125-2-3 2 socket Barber-Coleman P-100-8 1 relay Barber-Coleman P-127-2-4 1 socket Barber-Coleman P-100-4 1 electrical control Barber-Coleman TP-8101 1 meter Barber-Coleman ASP-521 1 meter Barber-Coleman ASP-561 1 meter Barber-Coleman ASP-562 2 meter Barber-Coleman ASP-563 5 electrical control Barber-Coleman TP-3201 5 temp indicator Barber-Coleman TSP-8111 Page 2 of 12

5 CELLHOUSE 5 Air Handler Units Carrier 1 centrifugal chiller York YRTCTDTO-46C SEWM-585090 1 cooling tower Balt.Air Coil LT1N220 U065010701 1 refrigerant monitor Bacharach 3015-5043 QR1014 fan coil units- DELETE 2 cw pumps Lincoln TV-3012 2 hw pumps Lincoln TV-2996 2 clg tower pumps Lincoln TV-2557 2 switch Barber-Coleman F61KB-11 1 relay Barber-Coleman P-125-2-3 1 socket Barber-Coleman P-100-6 1 relay Barber-Coleman P-127-2-4 1 socket Barber-Coleman P-100-4 1 relay Barber-Coleman P186-5-2 1 socket Barber-Coleman P-100-2 1 bulb tsiat Barber-Coleman TC-4111 2 ele trans Barber-Coleman TS-8201 1 outdoor sensing Barber-Coleman TS-8501 1 valve Barber-Coleman VP-2024-611-1-10 1 valve Barber-Coleman VP-2024-611-12 1 ele bridge Barber-Coleman CN-3101 1 controller Barber-Coleman CP-8102 1 relay Barber-Coleman P-125-2-3 1 socket Barber-Coleman P-100-8 1 relay Barber-Coleman P-127-2-4 1 socket Barber-Coleman P-100-4 2 electric sensing Barber-Coleman TS-8201 1 valve Barber-Coleman VP2124-659-1-7 1 valve Barber-Coleman VP-2124-659-1-9 1 valve Barber-Coleman VP-2124-659-1-11 2 controller Barber-Coleman CP-8102 3 flow switches Barber-Coleman F61KB-11 1 acuator Barber-Coleman MP-471-600 1 bulb tsiat Barber-Coleman TC-4114 1 electric sensing Barber-Coleman TS-8201 1 valve Barber-Coleman VA-2021-28-1-10 1 relay Barber-Coleman P-127-2-4 1 socket Barber-Coleman P-100-4 3 actuators Barber-Coleman MP-471-600 3 actuators Barber-Coleman MP-481-600 3 actuators Barber-Coleman MP-471-800 3 press switch Barber-Coleman PC-301 3 duct tsiat Barber-Coleman TC-5141 3 electronic sensing Barber-Coleman TS-8201 3 valve Barber-Coleman VA-8041-213-1-10 3 valve Barber-Coleman VA-8041-213-1-10 1 valve Barber-Coleman VA-8041-213-1-11 2 relay Barber-Coleman P-127-2-4 6 socket Barber-Coleman P-100-4 6 power supp Barber-Coleman ASP-8301 3 room ctrl Barber-Coleman TP-8101 4 actuators Barber-Coleman MP-471-800 2 actuators Barber-Coleman MP-481-600 2 press switch Barber-Coleman PC-301 2 duct tsiat Barber-Coleman TA-3431 2 duct tsiat Barber-Coleman TC-5141 2 electronic sensing Barber-Coleman TS-8201 Page 3 of 12

2 valve Barber-Coleman VA-8041-213-1-9 2 valve Barber-Coleman VA-8041-213-1-10 2 positioner Barber-Coleman AD-8301 2 relay Barber-Coleman P-127-2-4 2 socket Barber-Coleman P-100-4 2 relay Barber-Coleman P-127-2-4 2 socket Barber-Coleman P-100-4 2 elec ctrl Barber-Coleman TP-8101 1 elec tsiat Barber-Coleman TC-1101 JCI Metasys control circuit MECHANICAL EQUIPMENT 6 CELLHOUSE 8 Air Handler Units McQuay 1 Chiller York YCWL118SE 2CWM005924 1 COOLING TOWER Baltimore Air Coil VTO-102-L U107308901 1 Refrigerant Monitor Bacharach 3015-5043 QQ1045 1 air compressor 2 clg tower Bell & Gossett 2 cw pumps Bell & Gossett 2 hw pumps Bell & Gossett 4 cir pumps Bell & Gossett 1 cir pumps Bell & Gossett 1 cir pumps Bell & Gossett JCI Metasys control circuit TEMPERATURE CONTROLS 2 avg amu Johnson C-2040-1 6 air flow switch Johnson P-5237-1 4 3-way valve Johnson V-6135-1 18 sig Select Johnson C-5226-3 6 damper oper Johnson D-3153-2 10 hi limit Johnson A25-AN-1 6 lo limit Johnson A40FA-1 6 min pos switch Johnson R-4000-3 14 p.e.switch Johnson P10-BC-7 6 receiver controller Johnson T-9002-1 10 reversing sequencer Johnson C-208-2 22 temp ctrl Johnson T-5312-1 26 temp tran Johnson T-5210-1114 6 temp tran Johnson T-5210-1004 6 temp tran Johnson T-5210-1008 6 3-way valve Johnson V-4324-1005 6 chill water valve Johnson V-4324-1008 4 hot water valve Johnson V-4324-1001 4 chill water valve Johnson V-4324-1004 3 sig select Johnson C-5226-3 1 damper oper Johnson D-3244-4 2 sci air valve Johnson V11HAA-100 2 flow switch Johnson F4DAA-1 7 p.e. switch Johnson P71001-1 12 p.e. switch Johnson P10BC-7 1 rec cntrl Johnson T-9002-1 1 rec cntrl Johnson T-9001-1 4 sel switch Johnson S-232-1 2 temp tran Johnson T-5210-1002 2 temp tran Johnson T-5210-1004 1 dup air compressor Ingersoil-Rand 2-242-d2 1 air dryer Johnson A-4210-1 Page 4 of 12

1 3-way valve Johnson V6135-1 3 room stat Johnson T-4002-202 1 room stat Johnson T-47570-201 1 room stat Johnson T-4002-201 1 hot water valve Johnson V4324-1009 1 chill water valve Johnson V4324-1003 1 domestic hw controls Johnson T-5800-1 GARMENT PLANT 1 Unit w/copeland compressors Heil Quaker 9RTI-1505-TSC-800 1 Air Handler York NC180C00D6AAA2A N1C1835976 1 Outdoor Unit York YC180C00A2AAA2A N1G-1233893 1 Air Handler Trane TWE180B00EL 7443MR57D 1 Outdoor Unit Trane TTA180C300GA 71915MXAD 2 Steam Coils Heil Quacker NEBR150020A GYM JCI Metasys control circuit 2 Siebe Actuators/Valves Siebe M5-7433 1 Flow switch for hot water MECHANICAL EQUIPMENT 2 RECIPROCATING COMPRES 1 CHILLER Carrier 2 CHILLER WATER PUMP Aurora 2 HOT WATER PUMPS Aurora 1 AIR HANDLING UNIT Trane INFIRMARY TEMPERATURE CONTROLS 2 flow switch McDonnel-Miller F64-3 1 mixed air control Barber-Coleman TP-402 1 OA & RA Barber-Coleman MP-470 1 low limit stat Barber-Coleman TC-492 1 exhaust damper act Barber-Coleman MP-470 1 hot water sensor Barber-Coleman TS-5201 1 OA sensor Barber-Coleman TS-8501 1 two input controller Barber-Coleman CP-8102 1 solid state drive Barber-Coleman CP-8301 1 converter valve Barber-Coleman VP-2024 1 bulb tsiat Barber-Coleman TC-205 1 bulb tsiat Barber-Coleman TC-203 1 bulb tsiat Barber-Coleman TC-202 2 electronic solid state dr Barber-Coleman CP-8301 1 cooling valve Barber-Coleman VPO-3044 1 cooing actuator Barber-Coleman MP-481 1 htg valve Barber-Coleman VP-3044 1 heating valve Barber-Coleman MP-481 1 heating actuator Barber-Coleman MP-481 8 room stats Barber-Coleman TP-8101 8 zone actu Barber-Coleman MP-481 8 solid state actu drives Barber-Coleman CP-8301 1 humidity sensor Barber-Coleman HS-5163 1 humidity valve Barber-Coleman VU-2452 1 humidity actuator Barber-Coleman MU-508 1 bulb tsiat Barber-Coleman TP-402 1 preheat valve Barber-Coleman VP-3044 Page 5 of 12

1 preheat valve act Barber-Coleman MP-371 1 room stat Barber-Coleman TP-101 1 hight stat Barber-Coleman TP-101 1 hot water pump 1&2 Barber-Coleman Starters 1 chiller water 1&2 Barber-Coleman Starters JCI Metasys control circuit Cold Storage FILTERS - ALL BELTS AND FILTERS ARE TO BE FURNISHED BY THE CONTRACTO 1 & 2 Building 32 Filter 2 Air Handlers 3 Cellhouse 10 Filter FARR Brand or Equiv 8 Filter FARR Brand or Equiv 4 Cellhouse 12 Filter 1 Air Handler 5 Cellhouse 68 Filter 5 Air Handlers 6 Cellhouse 36 Filter 6 Air Handlers Infirmary 1 Roll Media Roll Filter Air Guard Part#4F-DSF All filters for each HVAC unit must be the above recommended filters. Page 6 of 12

enance, repair or replace. SIZE 124 ton 5hp 7.5hp 7.5hp 1/2" Page 7 of 12

1" 1 1/2" 3/4" 1 1/2" 36 hp Page 8 of 12

Page 9 of 12

7.5hp 2hp 3hp 3hp.75hp.50hp Page 10 of 12

15 ton 2hp 2hp Page 11 of 12

OR 24"x24"x2" 16"x25"x2" 20"x25"x2" 16"x25"x2" 16"x25"x2" 25"x25"x2" Page 12 of 12