1 Exhibit II Equipment Lists & Sample Service Sheet Site - CBJTC Post Headquarters: Bldg pages Site 2 - CBJTC CSMS Buildings: Bldg pages Bldg pages Bldg pages Bldg pages Bldg. 44- page Sample Service Sheet - 2 pages Note: Equipment specific Service sheets for equipment and sites will be available at the mandatory site visit.
2 CBJTC Post HQ Building 2300 Exhibit II -Covered Equipment List Site IEQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAL NUMBER I AIR HANDLERS AHU- Central Station Air Handler Carrier 39MN06C090 S0780UOS06 with VFD, 0-5 HP AHU-2 Central Station Air Handler Carrier 39MN06C UOS08 with VFD, 0-5 HP AHU-3 Central Station Air Handler Carrier 39MN06C UOS09 with VFD, 0-5 HP AHU-4 Central Station Air Handler Trane CCDB AHU-S Central Station Air Handler Trane CCDB with VFD, 0-5 HP AHU-6 Central Station Air Handler Trane CCDB AHU-7 Central Station Air Handler Carrier 39MN06C090 S078US02 AHU-8 Central Station Air Handler Carrier 39MN06C090 S078US022 SERVICE FREqUENCY Operationals Filter Changes Comprehensive 4 6 SPLIT SYSTEM SS-l Split System Heat Pump Trane SS-2 Split System Heat Pump York SS-3 Split System Heat Pump Goodman SERVICE FREqUENCY Filter Changes 6 Condenser Coil Cleaning CBJTC August 2, 20
3 CBJTC Post HQ Building 2300 Exhibit II -Covered Equipment List Site I EQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE ~ MODEL ISERIAL NUMBER I PUMPS P- Circulating Pump Bell & Gossett 50 C A80 P-2 Condenser Water Pump Bell & Gossett 2BC P-3 Hot Water Pump Bell & Gossett /4BC SERVICE FREQUENCY CHILLER IAC- I Water Cooled Chiller I Carrier I 30HCl06 I 0508Q08739 I SERVICE FREQUENCY Chiller Tube Brushing MISC EQUIPMENT CT- Cooling Tower with Strainer I Marley I HWB- Hot Water Boiler I Burnham PF504 I SERVICE FREQUENCY TIMES PER YEAR 2 CBJTC August 2, 20
4 IEQUIPMENT # CBJTC Post HQ Building 2300 I EQUIPMENT TYPE I Exhibit II -Covered Equipment List Site MANAFACTURE I MODEL I~SE-R-IA-l-N-U-M-B-E-R""I CONTROLS IDDC-l I Building Automation System I Johnson Controls I Metasys G-l I I Network Application Engine (NAE-4s) level one controller 3 Field Equipment controllers level two controller 26 Variable Air Volume Modular Assembly Variable Drive 5 I Variable Drive I I I I SERVICE FREQUENCY TIMES PER YEAR 3 CBHC August 2, 20
5 CBJTC - CSMS ADMIN BLDG 400 Exhibit II - Coverd Equipment List Site 2 I EQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE ~ MODel ISERIAL NUMBER I AIR HANDLERS AHU- Air Handler Unit, Return York Tl-0205-FAKA046A AHU-2 Air Handler Unit, Return York Tl FAA046A Filter Changes 4 Evaporator Coil Cleaning Comprehensive SPLIT SYSTEM I I I I I 55- Split System 0-5T TIMES PERYR Filter Changes 4 Condenser Coil Cleaning PUMPS P- Circulating Pump B+G 50 P-2 Circulating Pump B+G 50 TIMES PERYR CBJTC December 2, 20
6 CBJTC - CSMS ADMIN BLDG 400 Exhibit II - Coverd Equipment List Site 2 ~ EQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAL NUMBER I CHILLER IAC- I Air Cooled Chiller I York I YCA0060EC46 I I Operationals Comprehensives Coil Cleaning Oil Analysis TIMES PERYR 4 HEATERS HG- Heater, Gas Infrared Robert Gordon HG-2 Heater, Gas Infrared Robert Gordon HG-3 Heater, Gas Infrared Robert Gordon TIMES PER YEAR CONTROLS Building Automation System Metasys C- VMA Controller (QTY 3) Johnson Control C-2 D-900 Controller (QTY ) Johnson Control C-3 MIG Controller (OTY ) Johnson Control C-4 UNT Controller (OTY ) Johnson Control Times PerYr Comprehensive 2 CBHC December 2, 20
7 CBJTC - CSMS ADMIN BLDG 400 Exhibit \ - Coverd Equipment List Site 2 r EQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAL NUMBER I EHAUST FANS EF- Ceiling Mounted Exhaust Fan Greenheck EF-2 Ceiling Mounted Exhaust Fan Greenheck EF-3 Ceiling Mounted Exhaust Fan Greenheck 5BE-3H24-S TIMES PER YEAR Operationals 2 VAVBO I I I I I IVB- VAV Box (OTY 7) Trane TIMES PERYR Filter Changes 6 3 CBJTC December 2, 20
8 CBJTC - CSMS Allied Trades BLDG 404 Exhibit" - Coverd Equipment List - Site 2 IEQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEl ISERIAL NUMBER I AIR HANDLERS IAHU- I Air Handler Unit, Mixed Vari Volume I 0-40HP I I Operationals Filter Changes Evaporator Coil Cleaning Comprehensive TIMES PERYR 4 4 AIR HANDLER IAHU-2 IAir Handler Unit, Mixed Const Vol (QTY 5) I I 0HP I Operationals Filter Changes Comprehensives TIMES PERYR 4 4 SPLIT SYSTEM ISS- I Split System (QTY 2) I 0-lST I Operationals Filter Changes Condenser Coil Cleaning Comprehensive 4 4 CBJTC December 2, 20
9 CBJTC - CSMS Allied Trades BLDG 404 Exhibit II - Coverd EauiDment List - Site 2 EQUIPMENT # EQUIPMENT TYPE MANAFACTURE I MODEL SERIAL NUMBER AIR COMPRESSOR I I I IAC- Air Compressor, Commercial Commercial I 5-20HP AIR COMPRESSOR I I I I I IAC- Air Compressor, Industrial (QTY 3) Industrial HP HEATERS Preventive Maintenance I I I I I IHG- Heater, Gas Infrared (QTY ) Robert Gordon TIMES PER YEAR CONTROLS I I I I IC-4 UNT Controller (QTY ) Johnson Control ASC Times PerYr Comprehensive 2 CSHC December 2, 20
10 I EQUIPMENT # I EQUIPMENT TYPE CBJTC - CSMS Allied Trades BLDG 404 Exhibit II - Coverd Equipment List - Site 2 I MANAFACTURE I MODEL ISERIAL NUMBER I EHAUST FANS IEF-l I Wall Mounted Exhaust Fan (OTY 2) I I O-SHP I I TIMES PER YEAR Operationals 2 EHAUST FANS I I I I I IVAF-l Vane Axial Fan 3FT Dia Times Per Yr Comprehensive VARIABLE DRIVE IVD-l I Variable Spd Drive (Mech Lg) I Mech-Lg I I I Times PerYr Comprehensive 3 CBJTC December 2, 20
11 CBJTC - CSMS Electronics BLDG 405 Exhibit II - Coverd Equipment List Site 2 IEQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAL NUMBER I AIR HANDLERS AHU- Air Handler Unit Mixed, Const Volume I 0HP AHU-2 Air Handler Unit, Mixed Vari Volume I 0-40HP Filter Changes 4 Evaporator Coil Cleaning Comprehensive AIR HANDLER IAHU-3 IAir Handler Unit, 00% OSA Const volumel I 0HP I I Filter Changes 4 SPLIT SYSTEM I I I I I 55- Split System 0-lST Filter Changes 4 CBJTC December 2, 20
12 I EQUIPMENT # I EQUIPMENT TYPE CBJTC - CSMS Electronics BLDG 405 Exhibit II - Coverd Equipment List Site 2 I MANAFACTURE I MODEL ISERIAL NUMBER I HEATERS HG- HG-2 I I Heater, Gas Infrared Heater, Gas Infrared I I Robert Gordon Robert Gordon TIMES PER YEAR CONTROLS IC-4 I UNT Controller (QTY ) I Johnson Control I ASC Times PerYr Comprehensive EHAUST FANS EF- Wall Mounted Exhaust Fan I O-SHP VAF- Vane Axial Fan I SFT Dia TIMES PER YEAR Operationals 2 VARIABLE DRIVE IVD- Variable Spd Drive (Mech Sm) I Mech-Sm I I Times PerYr Comprehensive 2 CBJTC December 2, 20
13 IEQUIPMENT # I EQUIPMENT TYPE CBJTC CSMS Auto Service BLDG 406 Exhibit II - Coverd Equipment List Site 2 I MANAFACTURE I MODEl ISERIAl NUMBER I AIR COMPRESSOR IAC- I Air Compressor, Commercial (QTY 2) I Commercial I S-20HP I I TIMES PER YEAR HEATERS I IHG- Heater, Gas Infrared (QTY 2) Robert Gordon I TIMES PER YEAR CONTROLS I I I I IC- UNT Controller Johnson Control ASC I Times PerYr Comprehensive SPLIT SYSTEM 55- Split System (QTY 2) I I 0-lST I I Filter Changes 4 Condenser Coil Cleaning Comprehensive CBJTC December 2, 20
14 CBJTC - CSMS Storage BLDG 44 Exhibit II -Coverd Equipment List Site 2 IEQUIPMENT # I EQUIPMENT TYPE I MANAFACTURE I MODEL ISERIAl NUMBER I EHAUST FANS EF-l EF-2 Wall Mounted Exhaust Fan Wall Mounted Exhaust Fan TIMES PERYR Comprehensive HEATER IUH-l I Unit Heater I I I I Condenser Coil Cleaning CBJTC December 2,20
15 Sample Service Sheet Sample -Type of Equipment Comprehensives Contact customer representative for performance issues Check starter and contactor Check and tighten electrical connections Inspect pilot and safeties (as applicable) Check flame quality Check coil conditions Check filter condition Check and clean condensate pan and drain If accessible Check safety control set points Check damper operation and lubricate as required Change belt(s) LnecK vaive{s} }\ Check and lubricate fan and motor bearings Check for proper fan rotation Check condition of blower assembly Check for unusual noises, vibration and wear Report recommendations Check overall condition of unit Clean area around equipment Complete any required maintenance checklists, report observations to appropriate customer representative Operationals Complete any required maintenance checklists, report observations to appropriate customer representative Clean area around equipment Check overall condition of unit > > J::.... l0 t: OJ > 0 -e loro ro ~ I OJ :J > c:e 0 Check for unusual noises, vibration and wear Report recommendations Check fan operation Visually Inspect damper(s) Check filter condition
16 Sample Service Sheet >..c > -+oj ""C c Q) > 0 -+oj L ""C ro ~ ro Sample -Type of Equipment I Q) ::J > co (j Operationals continued Check with appropriate customer representative for operational deficiencies Check belt(s) (if applicable) Check coil conditions Secure and check all electrical connectors Inspect fan wheel for free movement, excessive play and debris Confirm that all mounting hardware is tight Clean and Paint corroded areas as necessary Check condensate pan and drain If accessible Filters, Misc. Dispose of dirty filter appropriately Turn equipment on Install new filters Remove dirty filters Turn equipment off Lubricate & inspect fan bearings. Replace air filters per agreement Check with appropriate customer representative for operational deficiencies IComplete any required maintenance checklists, report observations to appropriate customer representative 2
REQUEST FOR PROPOSALS FOR THE PROVISION OF PREVENTIVE MAINTENANCE ON FACILITY HVAC SYSTEMS FOR SKOKIE PUBLIC LIBRARY
REQUEST FOR PROPOSALS FOR THE PROVISION OF PREVENTIVE MAINTENANCE ON FACILITY HVAC SYSTEMS FOR SKOKIE PUBLIC LIBRARY Skokie Public Library is requesting proposals for a contract for the provision of preventive
More information"This is only the scope of work for the project. For more information, interested parties should contact Procurement at
"This is only the scope of work for the project. For more information, interested parties should contact Procurement at purchasing@stpgov.org to ensure receipt of a full bid package, to be listed as a
More information"This is only the scope of work for the project. For more information, interested parties should contact Procurement at
"This is only the scope of work for the project. For more information, interested parties should contact Procurement at purchasing@stpgov.org to ensure receipt of a full bid package, to be listed as a
More informationPreventative Maintenance Tables
Preventative Maintenance Tables Table of Contents I. Table : Gas Fired Domestic Hot Water Heater II. III. IV. Table : Circulating Pump Table : Convectors Table 4: Grille and Diffusors V. Table 5: Unit
More informationDESIGN GUIDELINES SECTION HVAC
3/15/17 Cooling Methodology Chiller Plants Configurations monitoring Preferred DESIGN GUIDELINES SECTION 15700 HVAC Air-cooled chillers < or = 300 tons; water-cooled chillers > 300 tons Variable volume
More informationPITTSBURG STATE UNIVERSITY. HVAC and BUILDING AUTOMATION SYSTEM STANDARDS
PITTSBURG STATE UNIVERSITY HVAC and BUILDING AUTOMATION SYSTEM STANDARDS CHILLERS In new construction, liquid-cooled models are preferred for systems larger than 100 ton. o Trane, York and McQuay brands
More informationGreen Maintenance Needed to Keep HVAC Systems Green
Green Maintenance Needed to Keep HVAC Systems Green Robert G. (Bob) Baker BBJ Consulting Service 235 Apollo Beach Blvd. #157 Apollo Beach, Florida bbaker@bbjconsultingservice.com ASHRAE is a Registered
More informationCARNEGIE-STOUT PUBLIC LIBRARY REQUEST FOR PROPOSALS FOR HVAC MAINTENANCE
Carnegie-Stout Public Library 360 West 11th Street Dubuque, Iowa 52001-4697 (563) 589-4225 office (563) 589-4217 www.dubuque.lib.ia.us CARNEGIE-STOUT PUBLIC LIBRARY REQUEST FOR PROPOSALS FOR HVAC MAINTENANCE
More informationBID SPECIFICATIONS FOR HVAC MAINTENANCE & SERVICE LOCATED AT VARIOUS BUILDING LOCATIONS FOR CITY OF ZION, ILINOIS
BID SPECIFICATIONS FOR HVAC MAINTENANCE & SERVICE LOCATED AT VARIOUS BUILDING LOCATIONS FOR CITY OF ZION, ILINOIS The City of Zion is requesting bids for the HVAC Maintenance & Services to be performed
More informationHVAC Efficiency In Healthcare. Presenter Mr. Nate Lincoln
HVAC Efficiency In Healthcare Presenter Mr. Nate Lincoln nlincoln@greenairenv.com 1.800.789.3734 Learning Objectives Control Systems Annuals; Chillers, Cooling Towers, Air Handler Units Infection Control
More informationNovember 11, City of Sparks 215 S. 21 st St. Sparks, NV
November 11, 2014 City of Sparks 215 S. 21 st St. Sparks, NV 89432-0857 Attn: Brian Cason Re: Sparks City Hall HVAC Upgrade Project-Alerton Direct Digital HVAC Control System to Match Existing City of
More informationRECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS
RECOMMENDED PROCEDURES FOR THIRD-PARTY PREVENTATIVE MAINTENANCE PROVIDERS 1 Contents Introduction... 3 Portfolio Energy Goals... 3 Purpose of This Document... 3 Gas Furnaces... 4 Electric Furnaces... 7
More informationDescription of All Alternatives Considered-
Description of All Alternatives Considered- Energy efficiency is an area where the Tubman design can be improved. The design heating load is 1807.8 MBH and the design cooling load is 1702.2 MBH or 142
More informationMECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION CONDITIONS FACILITIES MASTER PLAN MAY
MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION CONDITIONS FACILITIES MASTER PLAN MAY 2018 57 MECHANICAL ASSESSMENT MECHANICAL ASSESSMENT This report section includes an overview of the existing
More informationRHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW
INSTALLATION INSTRUCTIONS RHGN-H: COMMERCIAL AIR HANDLER WITH VARIABLE FREQUENCY DRIVE (VFD) NOMINAL 10 TONS R-410A REFRIGERANT 2-STAGE AIR-FLOW 92-106595-01-00 TABLE OF CONTENTS Introduction.......................................
More informationTop of the World Tower
Workplace Building Preventive Maintenance Checklist conducted for Top of the World Tower Conducted on 22 Oct 2018 11:00 AM Prepared by Greg Langley Location 1247 Dartmouth St, Albany, CA 94706, USA Completed
More information40 RM/RMS Packaged Air-Handling Units
ConcepcionCarrier Air conditioning Company Philippines 40 RM/RMS 008034 Packaged AirHandling Units INSTALLATION MANUAL, STARTUP & SERVICE INSTRUCTIONS Contents Page Page Safety Considerations 1 40RM Physical
More informationCxA to Answer this Section
EXHIBIT 01 91 13-3, SAMPLE Construction checklist items are to be completed as part of initial checkout and subsequent startup, preparatory to Functional testing. This checklist does not take the place
More informationInternal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.
A-D WITH MPU SPECIFICATION WRITTEN SPECIFICATION Description A Modular Packaged Heating, Cooling and ventilating unit(s), as indicated on the drawings shall be furnished. Direct Fired Gas Unit(s) shall
More information48 50 UH UA PACKAGED ROOFTOP
48 50 UH UA PACKAGED ROOFTOP SPARE PARTS GENERAL VIEW FIGURE.1 50 UH-UA 045 FIGURE.2 48-50 UH 045 1 Suction and discharge line piping 2 Liquid line piping 3 Heaters 4 Outdoor fan assembly 5 Indoor fan
More informationA. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution systems.
15855 AIR HANDLING UNITS SPECIFIER: CSI MasterFormat 2004 number: 237313 PART 1 GENERAL 1.1 SUMMARY A. Section includes Factory Packaged, Modular units, providing cooling and heating for air distribution
More informationThis is to inform you the Equipment List has been added to this Invitation for Bid and the BID OPENING date has been postponed
June 2, 2014 MEMORANDUM TO WHOM IT MAY CONCERN FROM: Janell Kim Financial Services Director SUBJECT: ADDENDUM NO. 2 INVITATION FOR BID NO. J15013 TO PROVIDE MAINTENANCE SERVICE, AND CHEMICAL WATER TREATMENT
More information1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT
Taylor Engineering 1080 Marina Village Parkway, Suite 501 Alameda, CA 94501-1142 (510) 749-9135 Fax (510) 749-9136 LLC HVAC DESIGN INTENT PART 1 - GENERAL 1.1 Overview A. The project consists of a 3-story
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More informationNEW CHILLER SCHEDULE
TITLE: REPLACE CHILLER MACC MAXIMO # 4542690 PROJECT # 14M108CN MACC # 14-0459 ATTACHMENTS: 1. MAXIMO Equipment update form SCOPE OF WORK: The contractor shall provide all material, labor, equipment, and
More information21. Plumbing fixture mixing valves, PRV, electronic faucets and flush valve(excluding batteries)optional Cost proposal to include these device
DIVISION 23800 APPENDIX A ASHTABULA CAMPUS: 1. Air Handling Equipment And Appurtenances 2. Exhaust Fans 3. Fume Hood Exhaust Fans 4. Fume Hood monitoring devices and annual certification of face velocity
More informationQUANTITY EQUIPMENT MANUFACTURER MODEL NUMBER SERIAL NUMBER
Kentucky State Penitentiary All equipment listed below shall be the responsibility of the vendor to perform preventive maint All model/control numbers are correct to the best of all knowledge. QUANTITY
More informationTechnical Assignment 3 11/15/04. Executive Summary
Executive Summary This report is an analysis of the existing systems within the Outreach Innovation Building in University Park, PA. One significant design criteria was a lower than average noise criteria
More informationSECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL
SECTION 15910 SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division
More informationSECTION HVAC TABLE OF CONTENTS PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS FILED SUB BID PROJECT OVERVIEW...
SECTION 230001 TABLE OF CONTENTS SECTION 230001 PART 1 - SYSTEM DESCRIPTION / OUTLINE SPECIFICATIONS... 1 1.00 FILED SUB BID... 1 1.01 PROJECT OVERVIEW... 2 1.02 DESIGN CRITERIA... 4 1.03 CODE ISSUES...
More informationSystem Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.
System Components with ` Emphasis on Packaged Rooftop Application and Installation Jerry Cohen President Jacco & Assoc. Agenda Define and relate in practical terms the following components: System Effect
More informationHORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).
SECTION 15555 HORIZONTAL FIRE TUBE BOILERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15510 - Piping (HVAC). 2. 15540 - Pumping Equipment (HVAC). 1.02 SUBMITTALS A. Submit properly identified
More informationA. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.
SECTION 238113 - PACKAGED TERMINAL AIR CONDITIONERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationSunny Hills. HVAC Maintenance Checklist Template. conducted for. Conducted on 31 Oct :40 PM. Prepared by Jon Nieve
HVAC Maintenance Checklist Template conducted for Sunny Hills Conducted on 31 Oct 2018 03:40 PM Prepared by Jon Nieve Location 102 S Mendel St, Fort Stockton, TX 79735, USA Completed on 31 Oct 2018 04:11
More informationCity of Duluth Festival Center 04/25
SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationLiebert DataMate (1-3 Ton) Warranty Inspection Check Sheet
The following information must be fully completed and forwarded to your local Liebert sales office to establish your equipment warranty. Installer Address Owner Address Owner e-mail address Installation
More informationSECTION SPLIT-SYSTEM AIR-CONDITIONERS
SECTION 238126 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationChilled Water system
Chilled Water system Introduction For large installations the Condenser, Evaporator, Compressor and Expansion device can be purchased as a package unit, known as a Chiller. The usual package consists of
More informationLiebert InteleCool Warranty Inspection Check Sheet
The following information must be fully completed and forwarded to your local Liebert sales office to establish your equipment warranty. Installer _ Address Owner Address Owner e-mail address Installation
More informationAIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.
SECTION 15855 AIR HANDLING UNITS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15240 - Vibration Isolation. 2. 15885 - Air Filtration Equipment. 3. 15890 - Ductwork. 1.02 REFERENCES A. Air Moving
More informationDirect Fired Heater Model AD Specification
Direct Fired Heater Model AD Specification Description A Direct-fired gas heating and ventilating unit(s), as indicated on the drawings shall be furnished. Unit(s) shall be tested in accordance with ANSI
More informationCOHASSET, MA March 6, The following is the HVAC outline specifications, which defines the scope of work of the HVAC system.
23 00 00 HEATING, VENTILATING & AIR-CONDITIONING The following is the HVAC outline specifications, which defines the scope of work of the HVAC system. PART 1 GENERAL 1.1 CODES A. All work installed under
More informationCENTRAL, SPLIT SYSTEM REFRIGERATED AIR-CONDITIONING INSPECTION INTERIOR
Consulting, Resource, Education, Training, and Support Services for Home Inspectors A candle loses no light when it lights another candle. CENTRAL, SPLIT SYSTEM REFRIGERATED AIR-CONDITIONING INSPECTION
More informationConstruction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA
Construction Standards Page 233423-1 Copyright 2009 by The American Institute of Architects (AIA) Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA Modified
More informationAppendix 13. Categories of Cooling and Heating systems
EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01
More informationMECHANICAL SERVICES 101. Ian White
MECHANICAL SERVICES 101 Ian White Contents 1. Ventilation 2. Heat Gains & Losses 3. Heating Ventilation Air Conditioning (HVAC) Systems What are Building Services Building Services incorporate all aspects
More informationDSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data
DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal
More informationFLORIDA A&M UNIVERSITY PERFORMANCE CONTRACT SCOPE OF WORK
FLORIDA A&M UNIVERSITY PERFORMANCE CONTRACT SCOPE OF WORK ENERGY CONSERVATION MEASURE 1 Partial Steam System Decentralization SIEMENS will Furnish and Install condensing hot water boilers with associated
More informationFlorida Department of Transportation
Page 1 of 7 RICK SCOTT GOVERNOR Florida Department of Transportation 1109 S. Marion Avenue Lake City, Florida 32025 ANANTH PRASAD SECRETARY September 27, 2011 To: Proposal Holders Addendum No: 1, E2Q23,
More informationSECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS
PART 1 - GENERAL SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and other equipment. B. See Division 23 Section
More informationSECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS
SECTION 23 09 93 SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes control sequences for HVAC systems, subsystems, and equipment. B. See Division 23 Section
More informationEQUIPMENT LIST TRACIE KEITH CONCORD, CA CONCORD AVENUE CONCORD, CA ID# SF1 SF2 SF3 RF1 EF2 EF3 FC CU DSS CU FC
1977 1 DISTRICT CENTER HOUSE CONCORD, CA 94524 1331 CONCORD AVENUE CONCORD, CA 94520 SF1 SF2 SF3 RF1 EF2 EF3 FC CU DSS CU FC EMS TRANE MCCA014UB000A00A0 K02B32244 SOLIDYNE EMS TRANE MCCA025UB000A00A0 K02B32237
More informationMEP CONDITION ASSESSMENT
MAINE EAST MEP CONDITION ASSESSMENT MAINE EAST HIGH SCHOOL This report section includes an overview of the existing mechanical cooling and heating systems serving Maine East High School. The sections will
More informationHeat Recovery Units. EXTERNAL STATIC REQUIRED (in.h2o) (Pa) MOTOR (Bhp/Hp) (bkw/kw) SPEED (rpm)
Heat Recovery Units AIR HANDLING UNIT No. SERVICE AREA MANUFACTURER MODEL HRU-3 & HRU-4 B-Section Low Rate Ventilation Tempeff RG 16000 (9500) SUPPLY FAN - SIZE/TYPE AIRFLOW RATE (cfm) (l/s) TOTAL STATIC
More informationVariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects
VariCool VAV (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water Unique Solutions for All-Indoor HVAC Projects Water Source Heat Pump Water-Cooled Chilled Water Modular
More informationProduct Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps
Product Data OMNIZONE 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons omnizonebwlogo 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE
More informationStanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT
SECTION 23 81 00 DECENTRALIZED UNITARY HVAC EQUIPMENT PART 1 - GENERAL 1.1 SUMMARY A. Section includes packaged roof top unit, unit controls, remote panel, roof mounting curb and base, maintenance service,
More informationThe County of Barry is accepting sealed bids for HVAC service. The term of the contract will be for the year beginning November 1, 2018 and ending
The County of Barry is accepting sealed bids for HVAC service. The term of the contract will be for the year beginning November 1, 2018 and ending October 31, 2021. The closing date for the bid is October
More informationTECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be
More informationDSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data
DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal
More informationMARVAIR SCHOLAR III HEAT PUMPS & AIR CONDITIONERS MODELS VAIA & VAISA EXPLODED VIEW PARTS ID
CABINET SHEET METAL (OUTER PANELS) 1 CABINET SHEET METAL (OUTER PANELS) 1 2 Left Side Door, Includes Exterior Panel and Perforated Interior Panel Right Side Door, Includes Exterior Panel and Perforated
More informationM2 Series Startup Form
M Series Startup Form Job Name: Date: Address: Model Number: Serial Number: Tag: Startup Contractor: Address: Phone: Pre Startup Checklist Installing contractor should verify the following items.. Is there
More informationTechnical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer
Technical Development Program PRESENTED BY: COMMERCIAL HVAC SYSTEMS Water Source Heat Pump Systems Ray Chow Sales Engineer TDP Updates Menu Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section
More information.2 Section Waste Management and Disposal.
Issued 2005/06/01 Section 15624 Packaged Rotary Screw Water Chillers Page 1 of 5 PART 1 General 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationConstruction Standards Page
Construction Standards Page 236313-1 SECTION 236313 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationCS 2. Central Station Air Handlers Double Wall & Single Wall Installation, Operation & Maintenance Manual. Form No. 6120A
CS 2 Central Station Air Handlers Double Wall & Single Wall Installation, Operation & Maintenance Manual Form No. 6120A TABLE OF CONTENTS Page Inspection... 2 Shipment of Units... 2 Handling... 2 Installation...
More informationPlenum Fans. Model HPA. Direct Drive
Plenum Fans Model HPA Direct Drive October 2012 Quiet & Efficient HPA Plenum Fans Greenheck s modular plenum fan, model HPA, is designed and engineered to provide superior performance and reliability in
More informationSECTION FAN COIL UNITS
PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Specification Sections, apply to this Section. B. Related Sections:
More informationPlumbing Backflow Prevention Drain Cleaning/ Lining/ Rehabilitation Heating Controls Pneumatics Radiant (in-floor) Heating Natural Gas Air
PORTFOLIO Background JW Plumbing and Heating has been servicing Montreal for 40 years. Originally a small plumbing company JW soon added heating to its list of service specialties. Over the years JW has
More informationDrying Tumblers Pound Capacity
Drying Tumblers 25-170 Pound Capacity Preventative Maintenance Please refer to your operating manual for detailed maintenance procedures. www.comlaundry.com Part No. 70323301R6 December 2009 Table of
More informationMCH Series Drives. HVAC Application Guide. ag-mch-e2
Drives HVAC Application Guide ag-mch-e2 % Flow, Torque, HP AFFINITY LAWS Most HVAC systems are designed to perform during peak load conditions that rarely occur during the year. Various flow control methods
More informationOperation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.
Spot Cooling Systems, Inc. 120 Century Drive Suite 00 Carrollton, TX 7006 00-6-776 Operation Manual SCT1B and SCT1B Warning! Improper installation, adjustment, alteration, service, or maintenance can cause
More informationPreventative Maintenance Equipment List
Administration Building 6162 South Willow Drive, Suite 100, Greenwood Village, CO 80111 Manufacturer Model Number Serial Number Air Filter Size Qty AD1 System/Air 1½ ton 24AHA418A003 Condensing (CND 01)
More informationMechanical Systems Design
Mechanical Systems Design After much deliberation and a long process of brainstorming ideas for potential mechanical system designs for the, it was finally decided to design a central chilled water plant
More informationKINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION
SECTION 237433, PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to
More informationMISSION CRITICAL Air Conditioning Systems. Maintenance Guide. ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4
MISSION CRITICAL Air Conditioning Systems Maintenance Guide ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Vertical Floor /Wall /Ceiling Mount - Maintenance Manual 2
More informationCOMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES /2012 Supersedes
COMMERICAL SPLIT SYSTEM KITS AND ACCESSORIES 506956 01 2/2012 Supersedes 506167 01 Litho U.S.A. TAA ECONOMIZERS INSTALLATION INSTRUCTIONS FOR ECONOMIZERS (44W94, 44W95 AND 44W96) USED WITH TAA SERIES UNITS
More informationService Step by Step Trouble-Shooting Check-List
WARNING: Only Data Aire trained technician or experience technicians should be working on Data Aire Equipment. Protect yourself at all times and work safe. Date: Dates at the job site: From: to Job#: Serial#:
More informationGARCIA GALUSKA DESOUSA Consulting Engineers
L#56566/Page 1/May 23, 2017 HVAC Heating Plant The original Town Hall building and Addition building are primarily heated by a gas fired hot water plant that is located in the basement. The boiler plant
More informationFILTERS MANIFOLD CABINET REFRIGERANT CONNECTION LOCATION
INDEX Introduction....................................... 3 Checking Product Received.......................... 3 Standard Unit Features.............................. 3 Unit Dimensions...................................
More informationAdvance Release September 2009
Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*
More informationA. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.
Page 238126-1 SECTION 238126 - This Section includes requirements for the LEED Rating System. However, equipment specified in this Section may not qualify for LEED Rating System prerequisites and credits.
More informationSubmitted to. Texas A&M University at Commerce The Texas A&M University System. Submitted by. Guanghua Wei Craig Campbell David Claridge Dan Turner
ESL-TR-99/12-09 Report of Energy Efficiency Study and Metering/Utilities Profile for Electricity Deregulation at the Texas A&M University at Commerce (TAMU-Commerce) Commerce, Texas Submitted to Texas
More informationDTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5
Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 01330 Submittal Procedures..2 Section 01355 Waste Management and Disposal..3
More informationDACC Health Sciences Building Air Handler Assessment/Study
DACC Health Sciences Building Air Handler Assessment/Study NMSU Facilities and Services Department P.O. Box 30001 Las Cruces, NM 88003-8001 June 14, 2016 Final Submittal 1065 S. Main St., Bldg. D, Ste.
More informationFan Selection. and Energy Savings
Fan Selection and Energy Savings Reducing power consumption by minimizing system pressure loss and choosing the right equipment HBy BRIAN MLEZIVA Greenheck Fan Corp. Schofield, Wis. Power Consumption HVAC
More informationHVAC 101. H V A C S y s t e m s
H V A C 1 0 1 S y s t e m s Introduction & Overview Should you care? Mechanical System Types Components & operation Popular Application Key Issues and Design Considerations System Comparisons First Cost
More informationTrane Family of Terminal Products
Trane Family of Terminal Products It s time to take another look at terminal. As your partner, Trane understands it takes more than a concept to design an effective HVAC system. Between cost and code compliance
More informationIntroduction to Fans. The Basics of Fan Principles and Terminology
Introduction to Fans The Basics of Fan Principles and Terminology Airflow Principles A fan is a rotating device that creates pressure differential that results in air movement Pressure rise in a fan Downstream
More informationCONTENTS. B. System Design and Performance Requirements
15625 Water Chillers This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes
More informationAdministration Building Garden City Terminal A/C Monthly P.M.
Administration Building A/C Monthly P.M. Condenser #1 Compressor # 1 2 3 4 Oil Level Ref. Level Head Press. Oil Press. Suction Press. Fan Motors 2 EA, Belts Fan # 1 2 3 Shaft Bearings 2 EA Shaft # 1 2
More informationT-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS MODELS UP TO 12.0 EER
T-SERIES COMMERCIAL SPLIT SYSTEMS 6- TO 20-TON ELP/ELS S UP TO 2.0 EER ALLIED COMMERCIAL T-SERIES MEANS ADVANCED TECHNOLOGY, RIGHT AWAY. Allied Commercial T-Series split systems are engineered with advanced
More informationAdministration Building Garden City Terminal A/C Monthly P.M.
Administration Building A/C Monthly P.M. Condenser #1 Compressor # 1 2 3 4 Oil Level Ref. Level Head Press. Oil Press. Suction Press. Fan Motors 2 EA, Belts Fan # 1 2 3 Shaft Bearings 2 EA Shaft # 1 2
More informationDENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION BASIC MECHANICAL REQUIREMENTS
PART 0 DESIGN STANDARDS 0.01 GENERAL DESIGN GUIDELINES A. Assume that buildings will be enlarged and modified in the future. 1. Make provisions for future interconnections, upgrading, and expansion of
More informationC13-Series Engineering Guide
Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................
More informationEnergy Recovery with Cooling and Heating
Energy Recovery with Cooling and Heating VersiVent - Model VER Commercial Institutional 2,000-10,000 cfm 3.0 in. wg external static pressure Configurable September 2008 Page The VersiVent Header Model
More informationUnico Presentation. Abridged iseries
Abridged iseries Combines all the efficiencies and performance of inverter technology with all the features and benefits of The Unico System Argoclima Group is a European leader in HVAC technology and
More informationb.) Technical Information:
Section VI- Strategies a.) Summary: It is important for new construction designers to consider the heating, ventilation, and air conditioning needs within a building. There are many different systems,
More informationSelecting the Correct Fan
Selecting the Correct Fan Ryan B. Johnson Air Purification Company Sales Engineer Member, ASHRAE Pikes Peak Chapter rjohnson@airpurificationcompany.com 1 Your Speaker circa 1998 Fan Types Applications
More informationDaikin Blueprint: Delivering Hot Water with a Chiller
Daikin Blueprint: Delivering Hot Water with a Chiller Analyzing the design of heat recovery on air-cooled chillers and the effect it has on building energy consumption By Paul Crisman Daikin Chiller Applications
More information