1 Administration Building 6162 South Willow Drive, Suite 100, Greenwood Village, CO Manufacturer Model Number Serial Number Air Filter Size Qty AD1 System/Air 1½ ton 24AHA418A003 Condensing (CND 01) First Company AD2 25CDXQR410TXV (FCU 01) Split System/Air AD3 2 ton 24ABB34BA E22623 Condensing (CND 02) AD4 (FCU 02) AD5 System/Air 2 ton 24ABB34BA E Condensing (CND 03) AD6 (FCU 03) 20x20x1 1 20x20x1 1 20x20x1 2 Garage Platform Pharma Room Garage Platform Page 1 of 9 Administrative Building

2 Administration Building 6162 South Willow Drive, Suite 100, Greenwood Village, CO Manufacturer Model Number Serial Number Air Filter Size Qty AD7 System/Air 2 ton 24ABB34BA E Condensing (CND 04) AD8 24x21.5x1 1 (FCU 04) 20x20x1 1 AD9 System/Air 2 ton 24ABB34BA E Condensing (CND 05) AD10 24x21.5x1 1 (FCU 05) 20x20x1 1 Page 2 of 9 Administrative Building

3 Aurora South E. Hampden Ave., Aurora, Colorado Manufacturer Model Number Serial Number Air Filter Size Qty AU1 Package/ary (RTU 01) York 7½ Ton DM090N15N2AAA4A N0L x25x2 4 AX49 2 AU2 Package/ary (RTU 02) York 7½ Ton DM090N15N2AAA4A N0G x25x2 4 AX49 2 AU3 Package/ary (RTU 03) 4 Ton YSC048G3RMA01A0B 1A1B000A00000F L 20x35x2 2 AU4 Package/ary (RTU 04) 3 Ton YSC036G3RLA01A0B 1A1B000A00000F L 20x35x2 2 AU5 Package/ary (RTU 05) 2 Ton 4YCY5024A1060AA L 20x25x1 1 AU6 Package/ary (RTU 06) 4 Ton YSC048G3RLA01D0B A1B000A00000F L 20x35x2 2 Page 3 of 9 Aurora South

4 Aurora South E. Hampden Ave., Aurora, Colorado Manufacturer Model Number Serial Number Air Filter Size Qty AU7 AU8 AU9 AU10 Package/ary (RTU 07) Package/ary (RTU 08) Package/ary (RTU 09) Air /Split System Condensing (CND 01) Fan Coil /Air Handler 3 Ton 2 Ton 3 Ton 1½ Ton YSC036G3RMA01D0B 1A1B000A00000F YCY5024A1060AA YSC036G3RLA01A0B1 A1B000A00000F TTR4018L1000AA AU12 (FCU 01) Exhaust Fan Assembly and Motor (EF 01) Cabinet Heater (CUH 01) Twin City DCRD095BE L L L 16495K27AF AU11 TAM4A0A18S11EDA BV L AU13 T16M47021 Air Filter Media 20x35x2 2 20x25x1 1 20x35x2 24x24x2 9x20x Electrical Room AX49 1 Entryway Page 4 of 9 Aurora South

5 11401 W. 122nd Ave.,, CO Manufacturer Model Number Serial Number Air Filter Size Qty WM1 Package/ary Air Johnson V33 N/S5 Conditioning Controls Series 40 25x20x ton (RTU 01) 25x16x2 4 2 WM2 Package/ary Air Johnson V33 N/S5 Conditioning Controls Series 40 25x20x ton (RTU 02) 25x16x2 4 2 WM3 Air 20x14x1 8 (FB/VAV 01) WM4 Air 20x14x1 8 (FB/VAV 02) WM5 Air 20x14x1 8 (FB/VAV 03) WM6 Air 20x14x1 8 (FB/VAV 04) Page 5 of 9

6 11401 W. 122nd Ave.,, CO Manufacturer Model Number Serial Number Air Filter Size Qty WM7 Air 20x14x1 8 (FB/VAV 05) WM8 Air 20x14x1 8 (FB/VAV 06) WM9 Air 20x14x1 8 (FB/VAV 07) WM10 Air 20x14x1 8 WM11 (FB/VAV 08) (PD/VAV 01) WM12 (PD/VAV 02) WM13 (PD/VAV 03) Page 6 of 9

7 11401 W. 122nd Ave.,, CO Manufacturer Model Number Serial Number Air Filter Size Qty (PD/VAV 04) (PD/VAV 05) (PD/VAV 06) (PD/VAV 07) (PD/VAV 08) WM14 WM15 WM16 WM17 WM18 WM19 (PD/VAV 09) Page 7 of 9

8 11401 W. 122nd Ave.,, CO Manufacturer Model Number Serial Number Air Filter Size Qty (PD/VAV 010) (PD/VAV 011) (PD/VAV 012) (PD/VAV 013) (PD/VAV 014) WM20 WM21 WM22 WM23 WM24 WM25 (PD/VAV 015) Page 8 of 9

9 11401 W. 122nd Ave.,, CO Manufacturer Model Number Serial Number Air Filter Size Qty WM26 WM27 WM28 WM29 WM30 WM31 (PD/VAV 016) Exhaust Fans and Motors (DF 01) Exhaust Fans and Motors (DF 02) Exhaust Fans and Motors (DF 03) Cabinet Style Electric Ventilators (CAB UH 01) Cabinet Style Electric Ventilators (CAB UH 02) Greenheck frac hp Greenheck frac hp Greenheck frac hp Johnson Controls Johnson Controls G070 3 G070 3 G070 3 FHP Series FHP Series 30x8x1 2 30x8x1 2 Entryway Entryway WM32 WM33 Gas Fired/Domestic Hot Water Heater (DOM HTR 01) Electric/Domestic Hot Water Heater (DOM HTR 02) AO Smith AO Smith BT 80 EJC 6 Mechanical Room Mechanical Room Page 9 of 9

EQUIPMENT LIST TRACIE KEITH CONCORD, CA CONCORD AVENUE CONCORD, CA ID# SF1 SF2 SF3 RF1 EF2 EF3 FC CU DSS CU FC

EQUIPMENT LIST TRACIE KEITH CONCORD, CA CONCORD AVENUE CONCORD, CA ID# SF1 SF2 SF3 RF1 EF2 EF3 FC CU DSS CU FC 1977 1 DISTRICT CENTER HOUSE CONCORD, CA 94524 1331 CONCORD AVENUE CONCORD, CA 94520 SF1 SF2 SF3 RF1 EF2 EF3 FC CU DSS CU FC EMS TRANE MCCA014UB000A00A0 K02B32244 SOLIDYNE EMS TRANE MCCA025UB000A00A0 K02B32237

More information

Sequence of Operations (excerpt)

Sequence of Operations (excerpt) Sequence of Operations (excerpt) Chilled Water System Consists of one (1) 600 cooling ton Trane CVHE 3 stage centrifugal chiller, with associated chilled water pumps, condenser water pumps and one (1)

More information

This is to inform you the Equipment List has been added to this Invitation for Bid and the BID OPENING date has been postponed

This is to inform you the Equipment List has been added to this Invitation for Bid and the BID OPENING date has been postponed June 2, 2014 MEMORANDUM TO WHOM IT MAY CONCERN FROM: Janell Kim Financial Services Director SUBJECT: ADDENDUM NO. 2 INVITATION FOR BID NO. J15013 TO PROVIDE MAINTENANCE SERVICE, AND CHEMICAL WATER TREATMENT

More information

Exhibit II Equipment Lists & Sample Service Sheet

Exhibit II Equipment Lists & Sample Service Sheet Exhibit II Equipment Lists & Sample Service Sheet Site - CBJTC Post Headquarters: Bldg. 2300-3 pages Site 2 - CBJTC CSMS Buildings: Bldg. 400-3 pages Bldg. 404-3 pages Bldg. 405-2 pages Bldg. 406- pages

More information

48 50 UH UA PACKAGED ROOFTOP

48 50 UH UA PACKAGED ROOFTOP 48 50 UH UA PACKAGED ROOFTOP SPARE PARTS GENERAL VIEW FIGURE.1 50 UH-UA 045 FIGURE.2 48-50 UH 045 1 Suction and discharge line piping 2 Liquid line piping 3 Heaters 4 Outdoor fan assembly 5 Indoor fan

More information

York Hvac Manuals Dl 20n30awaaa1a

York Hvac Manuals Dl 20n30awaaa1a York Hvac Manuals Dl 20n30awaaa1a May 27, 2008 Can someone tell me the tonnage of each of the following York RTU model numbers? AOP Commercial HVAC; York Tonnage by Model Number? Luxaire is a premier line

More information

This addendum responds to initial questions submitted by vendors.

This addendum responds to initial questions submitted by vendors. 5761 Keyo Building Orono, ME 04469-5761 Main:207-581-2712 ldd/tdy:207-973-3262 www.maine.edu REQUEST FOR PROPOSALS #125-2017 Mechanical & HVAC Preventative Maintenance, Inspection & Repair Services for

More information

Single zone RTU, controlled by a programmable thermostat. Single zone RTU, generic description, with power exhauster

Single zone RTU, controlled by a programmable thermostat. Single zone RTU, generic description, with power exhauster Rooftop Units CV Reheat RTU Reheat Reheat system RTU, serving electric reheat coils, w/dehumidification cycle & RA CO2 override of OAD CV Single Zone RTU SZ (from PC) RTU SZ Generic RTU SZ Multiple Units

More information

Job Name Control Systems Description Date

Job Name Control Systems Description Date Job Name Control Systems Description Date Project Overview The project is a describe the building and its major HVAC systems (e.g. three-story office building, served by a rooftop unit VAV system ). In

More information

COUNTY OF ROCKLAND Department of General Services Purchasing Division

COUNTY OF ROCKLAND Department of General Services Purchasing Division COUNTY OF ROCKLAND Department of General Services Purchasing Division Title: Contract Period: GE Variable Frequency Drives AF600 & Parts June 2, 2015 through June 1, 2016 w/2-1 yr options Extended through

More information

NYC Department of Education

NYC Department of Education Asset: P.S. 69 - STATEN ISLAND, 144 KEATING PLACE, New York, 10314 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-01-19 8:39 AM 2018-01-23 4:33 PM Asset Data Are there fuel tanks?

More information

MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN

MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN MID MICHIGAN COMMUNITY COLLEGE HARRISON CAMPUS Harrison, Michigan 2015 MASTER PLAN September 30, 2015 PBA Project No. 2015.0140.00 PETER BASSO ASSOCIATES INC. CONSULTING ENGINEERS 5145 LIVERNOIS ROAD,

More information

SAN ANTONIO WATER SYSTEM P. O. BOX 2449 SAN ANTONIO, TEXAS TABULATION OF BIDS

SAN ANTONIO WATER SYSTEM P. O. BOX 2449 SAN ANTONIO, TEXAS TABULATION OF BIDS GROUP 1 ANNUAL SERVICE / 15 ea. SERVICE 120.00 96.60 Tower 1, 1st Floor Electric Heat, 15x20x1, Pleated ANNUAL 120.00 96.60 / 9 ea. SERVICE 72.00 57.60 Tower 1, 1st Floor Electric Heat, 12x20x1, Pleated

More information

Sagebrush Elementary School East Temple Place Aurora, Colorado 80015

Sagebrush Elementary School East Temple Place Aurora, Colorado 80015 Sagebrush Elementary School 14700 East Temple Place Aurora, Colorado 80015 Year Opened 1977 Current Square Footage 57,100 Site Acreage 7.66 sagebrush.cherrycreekschools.org Asphalt and concrete work; electrical

More information

REQUEST FOR PROPOSALS FOR THE PROVISION OF PREVENTIVE MAINTENANCE ON FACILITY HVAC SYSTEMS FOR SKOKIE PUBLIC LIBRARY

REQUEST FOR PROPOSALS FOR THE PROVISION OF PREVENTIVE MAINTENANCE ON FACILITY HVAC SYSTEMS FOR SKOKIE PUBLIC LIBRARY REQUEST FOR PROPOSALS FOR THE PROVISION OF PREVENTIVE MAINTENANCE ON FACILITY HVAC SYSTEMS FOR SKOKIE PUBLIC LIBRARY Skokie Public Library is requesting proposals for a contract for the provision of preventive

More information

NYC Department of Education

NYC Department of Education Asset: P.S. 198 - BRONX, 1180 TINTON AVENUE, New York, 10456 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-01-24 8:14 AM 2018-01-24 9:32 PM Asset Data Are there fuel tanks? Total

More information

SHOE PALACE HUNTINGTON PARK M.200

SHOE PALACE HUNTINGTON PARK M.200 M.200 SPLIT SYSTEM CONDENSING UNIT SCHEDULE MARK SERVICE MODEL NO. COOLING DIMENSIONS ELECTRICAL REMARKS CAPACITY AMBIENT DB REFRIGERANT LENGTH WIDTH HEIGHT WEIGHT VOLT/PHASE MCA MOP (MBH) (DEG F) (IN)

More information

QUANTITY EQUIPMENT MANUFACTURER MODEL NUMBER SERIAL NUMBER

QUANTITY EQUIPMENT MANUFACTURER MODEL NUMBER SERIAL NUMBER Kentucky State Penitentiary All equipment listed below shall be the responsibility of the vendor to perform preventive maint All model/control numbers are correct to the best of all knowledge. QUANTITY

More information

DESIGN GUIDELINES SECTION HVAC

DESIGN GUIDELINES SECTION HVAC 3/15/17 Cooling Methodology Chiller Plants Configurations monitoring Preferred DESIGN GUIDELINES SECTION 15700 HVAC Air-cooled chillers < or = 300 tons; water-cooled chillers > 300 tons Variable volume

More information

Greenwood Elementary School 5550 South Holly Street Greenwood Village, Colorado 80111

Greenwood Elementary School 5550 South Holly Street Greenwood Village, Colorado 80111 Greenwood Elementary School 5550 South Holly Street Greenwood Village, Colorado 80111 Year Opened 1958 Current Square Footage 50,504 Site Acreage 8.53 greenwood.cherrycreekschools.org $220,720 Electrical

More information

Plain Elementary School 1370 Cherry St. Plain, WI 53577

Plain Elementary School 1370 Cherry St. Plain, WI 53577 FACILITIES PLANNING STUDY RIVER VALLEY SCHOOL DISTRICT Plain Elementary School 1370 Cherry St. Plain, WI 53577 7 South Dewey Street Eau Claire, Wisconsin 54701 715.832.1605 sdsarch.com PLAIN General Overview

More information

Technical Assignment 3 11/15/04. Executive Summary

Technical Assignment 3 11/15/04. Executive Summary Executive Summary This report is an analysis of the existing systems within the Outreach Innovation Building in University Park, PA. One significant design criteria was a lower than average noise criteria

More information

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT

1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT Taylor Engineering 1080 Marina Village Parkway, Suite 501 Alameda, CA 94501-1142 (510) 749-9135 Fax (510) 749-9136 LLC HVAC DESIGN INTENT PART 1 - GENERAL 1.1 Overview A. The project consists of a 3-story

More information

SOCIAL SECURITY ADMIN. GSA PEARL ST. BURLINGTON, Vt. EQUIPMENT INVENTORY LIST Concord NH R SHAW

SOCIAL SECURITY ADMIN. GSA PEARL ST. BURLINGTON, Vt. EQUIPMENT INVENTORY LIST Concord NH R SHAW INVENTORY LIST Concord NH R SHAW 1-6-2016 A-2 1 UNITARY, HEATING AND COOLING UNIT Mfr: YORK Model: DH180N24B2AAA2B Ser# N087468013 Heating BTU s 300,000 HP: 5 Tonnage: 15 2 UNITARY, HEATING AND COOLING

More information

Architectural Alliance Incorporated MDP CONSULTING ENGINEERS, INC N 11th Street Beaumont, TX 77702

Architectural Alliance Incorporated MDP CONSULTING ENGINEERS, INC N 11th Street Beaumont, TX 77702 04/08/2013 last saved: TRENT plotted: DRAWN BY: TLH CHECKED BY: DWD 04/08/2013 last saved: DMCPHERSON plotted: DRAWN BY: TLH CHECKED BY: DWD 04/08/2013 last saved: DMCPHERSON plotted: DRAWN BY: TLH CHECKED

More information

NYC Department of Education

NYC Department of Education Asset: J. K. ONASSIS HS FOR INT CAREERS-M, 120 WEST 46 STREET, New York, 10036 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2017-12-11 11:37 AM 2017-12-26 12:18 PM Asset Data Are there

More information

Outdoor Enclosure Manual

Outdoor Enclosure Manual Outdoor Enclosure Manual Mini-Fort Outdoor Equipment Enclosure August 7, 2013 Rev IR Table of Contents Release to this Technical Documentation...3 Using this Instruction Manual & Inspecting Shipment...4

More information

RFP P College-wide HVAC Service and Maintenance

RFP P College-wide HVAC Service and Maintenance RFP 632-14P College-wide HVAC Service and Maintenance Addendum 001 Issued January 14, 2015 Below are the questions we have received from various parties with respect to this Request for Proposal, along

More information

AGRICULTURE GROWING FACILITY 32905

AGRICULTURE GROWING FACILITY 32905 AVAILABLE AGRICULTURE GROWING FACILITY $7,900,000 S. Orchard Ln. S. Morcom St. 51,223 SF agricultural facility on 14.63 acres Building Improvements SF Admin Building 2,200 Lab # 1 1,440 Lab # 2 1,200 Trait

More information

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 25,240* Design CFM: 800 Seasonal

More information

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3. TS CE Combustion Enclosures with LMV3 February 12, 2019 Description TS CE series combustion enclosure with Siemens LMV3 linkageless controller sets the new standard for combustion control and monitoring

More information

Study Final Report. Priority Cool Refrigerant Study

Study Final Report. Priority Cool Refrigerant Study Refrigerant Study Study Final Report Prepared for: Greenway Solutions Company, Inc. 120 Bethpage Road, Suite 304 Hicksville, New York 11801 Prepared by: WSP Flack + Kurtz 512 Seventh Avenue New York, NY

More information

GENERAL. Model 2SD UAI-A Before installing read all of the manufacturers installation and maintenance instructions.

GENERAL. Model 2SD UAI-A Before installing read all of the manufacturers installation and maintenance instructions. ACCESSORY KIT INSTALLATION INSTRUCTION SMOKE DETECTOR KITS, UNIT MOUNT MODELS 2SD04700824, 2SD04700924 AND 2SD04701024 For 3.0 THRU 12.5 TON ROOFTOP UNITS GENERAL Before installing read all of the manufacturers

More information

AMC Theatres - Kansas

AMC Theatres - Kansas Peachtree Office/Retail Building - Georgia Skyscraper Rooftop Evaporative Cooler LEED Gold Status & Energy Star Hard to Clean Location AMC Theatres - Kansas Movie Theatre Rooftop Trane Equipment Remotely

More information

Campus Middle School 4785 South Dayton Street Greenwood Village, Colorado 80111

Campus Middle School 4785 South Dayton Street Greenwood Village, Colorado 80111 Campus Middle School 4785 South Dayton Street Greenwood Village, Colorado 80111 Year Opened 1971 Current Square Footage 175,743 Site Acreage (included in CCHS) 87.22 campus.cherrycreekschools.org $2,441,170

More information

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw) Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series

More information

UPFLOW WALL / CLOSET FAN COIL AIR CONDITIONERS ENGINEERING GUIDE

UPFLOW WALL / CLOSET FAN COIL AIR CONDITIONERS ENGINEERING GUIDE UP WALL / CLOSET AN COIL CONDITIONERS ENGINEERING GUIDE Models: YCW, YCWE and YCW-HW Standard unit shown (Closet application - ront Return Air) Unit shown with louvered wall panel (Recessed wall application)

More information

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811 Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage

More information

WITH HOT WATER HEAT 2 THRU 5 TONS SPLIT SYSTEM AHXW Series

WITH HOT WATER HEAT 2 THRU 5 TONS SPLIT SYSTEM AHXW Series aicoils AIR HANDLERS WITH HOT WATER HEAT 2 THRU 5 TONS SPLIT SYSTEM AHXW Series FEATURES o Air C onditioning or Heat P ump ready o P repainted galvanized steel cabinet o Internally lined with R 4.2, 1"

More information

Advance Release September 2009

Advance Release September 2009 Vertical Air Cooled DSV Series R 410A Model DSV096 DSV120 DSV144 DSV180 Nominal Cooling (Tons) 8 10 12 15 Refrigerant R 410A R 410A R 410A R 410A Cooling Performance Gross Cooling Capacity(Btu/h) 95,000*

More information

NYC Department of Education

NYC Department of Education Asset: BAYSIDE AF - QUEENS, 204-29 29TH AVENUE, New York, 11361 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2017-10-31 9:42 AM 2017-11-20 4:21 PM Asset Data Are there fuel tanks?

More information

Plumbing Backflow Prevention Drain Cleaning/ Lining/ Rehabilitation Heating Controls Pneumatics Radiant (in-floor) Heating Natural Gas Air

Plumbing Backflow Prevention Drain Cleaning/ Lining/ Rehabilitation Heating Controls Pneumatics Radiant (in-floor) Heating Natural Gas Air PORTFOLIO Background JW Plumbing and Heating has been servicing Montreal for 40 years. Originally a small plumbing company JW soon added heating to its list of service specialties. Over the years JW has

More information

Electrical Systems Existing Conditions and Building Load Summary Broadway Plaza, Rochester, MN. Appendix A

Electrical Systems Existing Conditions and Building Load Summary Broadway Plaza, Rochester, MN. Appendix A Appendix A Single Line Diagram Power Riser Diagram Dimming System Schematic Diagrams Dry-Type Transformer Schedule Primary Lamp and Ballast Table Mechanical Equipment Table Utility Rate Structure Breakdown

More information

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data July 28, 2008 Page 1 1 of 3 PROJECT: TAG: Gross Cooling Capacity [Btuh]: 37,800* Design CFM: 1,200 Seasonal

More information

VariCool EZ-Fit. Unique Solutions for All-Indoor HVAC Projects

VariCool EZ-Fit. Unique Solutions for All-Indoor HVAC Projects VariCool EZ-Fit 12 to 90 Tons Variable Air Volume Water-Cooled Water Source Heat Pump Chilled Water DOAS (Dedicated Outdoor Air System) Air-Cooled with Remote Condenser Unique Solutions for All-Indoor

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS HOT WATER AND STEAM COIL ACCESSORIES MODELS 1HW0410, 0411, 0412 and 1NF0456, 0457, 0458 For 7.5 Thru Ton Generation 2 Split System Indoor Units 643960-UAI-A-0910

More information

NYC Department of Education

NYC Department of Education Asset: P.S. 86 ANNEX - BRONX, 124 EAMES PLACE, New York, 10468 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-04-05 1:03 PM 2018-04-27 1:35 PM Asset Data Are there fuel tanks? Total

More information

MT. AIRY MIDDLE SCHOOL CARROLL COUNTY PUBLIC SCHOOLS

MT. AIRY MIDDLE SCHOOL CARROLL COUNTY PUBLIC SCHOOLS CARROLL COUNTY PUBLIC SCHOOLS LIFE CYCLE COST ANALYSIS SUMMARY DGS PROCEDURES FOR THE IMPLEMENTATION OF LIFE CYCLE COST ANALYSIS AND ENERGY CONSERVATION OCTOBER, 2010 G.A.I.#09090 GIPE ASSOCIATES, INC.

More information

YAH SERIES FAN COIL UNITS

YAH SERIES FAN COIL UNITS YAH Series Fan Coil Units Johnson Controls YORK YAH ceiling mounted cabinet fan coil units are terminal points of central air-conditioning systems. They are designed for fresh air units or to cool, heat,

More information

MODEL NUMBER NOMENCLATURE

MODEL NUMBER NOMENCLATURE MODEL NUMBER NOMENCLATURE DS 2200 BT P XXX OPTIONS: (SEE LIST BELOW) CONSTRUCTION: P - High Density Polyethylene FRP - Fiberglass CONFIGURATION: BT (Blow through) DT (Draw through) PA (Passive) CFM MODEL:

More information

AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU

AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU MULTISTACK was founded in 1989 by three highly respected, visionary HVAC industry executives.

More information

NYC Department of Education

NYC Department of Education Asset: PRE-K CENTER @ 7401 FORT HAMILTON PARKWAY - BROOKLYN, 7401 FORT HAMILTON PARKWAY, New York, 11228 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2017-11-27 11:12 AM 2017-11-27

More information

B E ROUTE DUCT BEHIND BOOKSHELF. GRILLE MOUNTED ON TOP OF BENCH. BOOK CASE WALL 12x8 8x5 I 8"Ø 7"Ø 125 CFM I D M FLOOR SIDE WALL VENT 6x5 160 CFM 6"Ø 6"Ø 8x10 J C G 1 Section M-1 NOT TO SCALE Project No

More information

Inspired Design With Heart

Inspired Design With Heart Inspired Design With Heart 9250 E. Costilla Ave. Greenwood Village, CO 80112 720-724-3149 designstudio-blue.com 01 02 03 04 Firm Profile Services Involvement Career Client List 01 Firm Profile Design Studio

More information

4. OVERVIEW OF MECHANICAL SYSTEM

4. OVERVIEW OF MECHANICAL SYSTEM 4. OVERVIEW OF MECHANICAL SYSTEM The 87,000 SF SLCC is served by six (6) Trane M-Series Climate Changer Air Handing Units (AHUs). Each unit serves a distinct zone within the facility that is unique in

More information

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

EnviroZone-4 & EnviroZone-2 Quick-Start Guide EnviroZone-4 & EnviroZone-2 Quick-Start Guide This guide is intended to give the installer a brief set of instructions about how to set up the FHP EnviroZone System. For more detailed information about

More information

ACCESSORY KIT INSTALLATION INSTRUCTIONS

ACCESSORY KIT INSTALLATION INSTRUCTIONS ACCESSORY KIT INSTALLATION INSTRUCTIONS 536306-UAI-B-1009 Electric Heat Accessory 10, 16, 20, 26, 32, 36 & 52kW For Split-System R-410A Air Handling Units Both Air Conditioners and Heat Pumps 7-1/2, 10,

More information

POSTING (DATE/TIME): FROM: / 5:00PM UNTIL: / 5:00PM Pgs. 1 of 12

POSTING (DATE/TIME): FROM: / 5:00PM UNTIL: / 5:00PM Pgs. 1 of 12 BID NUMBER: ITB-DOT-16/17-9011-GH BID TITLE: FDOT APL Traffic Equipment Supplemental STATE OF FLORIDA DEPARTMENT OF TRANSPORTATION BID TABULATION FAILURE TO FILE A PROTEST WITHIN THE TIME PRESCRIBED IN

More information

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description SCC Inc. TS Series TS-CE Combustion Enclosures with LMV5 June 25, 2018 Description TS-CE series combustion enclosure with Siemens LMV5 linkageless controller sets the standard for combustion control and

More information

LV Installation Manual

LV Installation Manual LV Installation Manual Includes: LV-50 LV-70 LV-120 LV-140 Manufactured By Energy Saving Products Ltd. Module-LV-Series-Installation-Manual-111915 INSTALLATION, OPERATING, AND MAINTENANCE MANUAL LO-V UNIT

More information

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL 25--21--65 Representative photo only, some models may vary in appearance. MANUFACTURED FOR NATURAL GAS CONVERTIBLE TO (LP) PROPANE GAS NOTE: These

More information

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL

SECTION SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL SECTION 15910 SEQUENCE OF OPERATION FOR HVAC CONTROLS PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division

More information

DRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS

DRAWING SCHEDULE TAB REQUIREMENTS BY EQUIPMENT TYPE TYPE OF EQUIPMENT DESCRIPTION COMPONENT TAB REQUIREMENTS DRAWING SCHEDULE NUMBER TITLE M0-1 MECHANICAL NOTES AND LEGEND M1-0 MECHANICAL FLOOR PLAN M4-0 MECHANICAL SCHEDULES M4-1 MECHANICAL LOAD CALCULATIONS M5-0 MECHANICAL DETAILS M8-0 TCS BASYS CONTROLS DRAWINGS

More information

Administration Building Garden City Terminal A/C Monthly P.M.

Administration Building Garden City Terminal A/C Monthly P.M. Administration Building A/C Monthly P.M. Condenser #1 Compressor # 1 2 3 4 Oil Level Ref. Level Head Press. Oil Press. Suction Press. Fan Motors 2 EA, Belts Fan # 1 2 3 Shaft Bearings 2 EA Shaft # 1 2

More information

Evaluation. ems. Prepared By: Martha. a s Vineyard. Box P.O. Box June 2015

Evaluation. ems. Prepared By: Martha. a s Vineyard. Box P.O. Box June 2015 Martha a s Vineyard Regional High School Vineyard Haven, MA 2 2015 HVAC Syste ems Evaluation Prepared For: Martha s Vineyard Regional School District Box 1385 Oaks Bluff, MA 02557 Prepared By: BLW Engineers,

More information

Administration Building Garden City Terminal A/C Monthly P.M.

Administration Building Garden City Terminal A/C Monthly P.M. Administration Building A/C Monthly P.M. Condenser #1 Compressor # 1 2 3 4 Oil Level Ref. Level Head Press. Oil Press. Suction Press. Fan Motors 2 EA, Belts Fan # 1 2 3 Shaft Bearings 2 EA Shaft # 1 2

More information

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE

SUBMITTAL DATA SHEET FEATURES. SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE SUBMITTAL DATA SHEET SPLIT-SYSTEM EVAPORATOR BLOWERS 7.5, 10, 15 & 20 TONS MODELS: NH-07 thru -20, 2-PIPE NJ-10 thru -20, 4-PIPE JOB NAME: LOCATION: PURCHASER: ORDER NO: ENGINEER: SUBMITTED TO: FOR: REF:

More information

Mechanical Technical Report 1. ASHRAE Standard 62.1 Ventilation Compliance Evaluation

Mechanical Technical Report 1. ASHRAE Standard 62.1 Ventilation Compliance Evaluation Mechanical Technical Report 1 Standard 62.1 Ventilation Compliance Evaluation Lutheran Theological Seminary at Philadelphia The New Learning Center Prepared For: William P. Bahnfleth, Ph.D., P.E. Department

More information

Replacements listed may not be an exact duplicate of original motor. HP RPM VOLTS FRAME BRGS. CAT. MODEL LIST MULT. F.L. APPROX.

Replacements listed may not be an exact duplicate of original motor. HP RPM VOLTS FRAME BRGS. CAT. MODEL LIST MULT. F.L. APPROX. OEM: Admiral-Emerson Single Phase, PSC Replaces Fasco No. D853 3 lug mounting 1/3 1300/3 230 48Y BALL X204 48A17O126 $162 F1 2.5 10 4 3/8 2 1/8 x 1/2 x 4 7/8 16 OEM: Amana/Rheem/Luxaire/Rooftop Package

More information

Appendix A. Project Location and Preferred Alternative Figures

Appendix A. Project Location and Preferred Alternative Figures Appendix A Project Location and Preferred Alternative Figures Figure 1: Project Location Map Figure 2A: Preferred Alternative Layout Sheet 1 Figure 2B: Preferred Alternative Layout Sheet 2 Figure 2C: Preferred

More information

Multifamily Program Gas Water Heaters: Sealed Combustion Crossover Products

Multifamily Program Gas Water Heaters: Sealed Combustion Crossover Products Multifamily Program Gas Water Heaters: Sealed Combustion Crossover Products Abstract The purpose of this paper is to document the benefits of using crossover gas water heating products that combine the

More information

NYC Department of Education

NYC Department of Education Asset: W.E.B. DUBOIS HS - BROOKLYN, 402 EASTERN PARKWAY, New York, 11225 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2017-12-04 1:02 PM 2017-12-27 4:16 PM Asset Data Are there fuel

More information

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007 Replacement Parts List No. 700002400 Revision D 11/2009 McQuay Acson Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR 20-50 Last Manufactured: 2007 To find your Daikin Applied

More information

Illustrated Parts List REFRIGERATED BACK COUNTER. Duke Manufacturing Company. MODEL: RBC 48 RBC 60 (Ending Serial # , Built 3/24/2017)

Illustrated Parts List REFRIGERATED BACK COUNTER. Duke Manufacturing Company. MODEL: RBC 48 RBC 60 (Ending Serial # , Built 3/24/2017) Illustrated Parts List RBC 60 RBC 48 REFRIGERATED BACK COUNTER MODEL: RBC 48 RBC 60 (Ending Serial # 03172774, Built 3/24/2017) This manual is Copyright 2018 Duke Manufacturing Co. All rights reserved.

More information

Air Cooled Scroll Compressor Condensing Unit

Air Cooled Scroll Compressor Condensing Unit Replacement Parts List No. 70000900 Rev. B 2/08 Air Cooled Scroll Compressor Condensing Unit ACZ Sizes: 00-039 Vintage: B R22, R407C Contents Contents... 2 Parts List Revision History... 3 Nomenclature

More information

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW

ADPF PRODUCT SPECIFICATIONS THREE-SPEED AIR HANDLER 1½ TO 5 TON DEDICATED DOWNFLOW ADPF THREE-SPEED AIR HANDLER The ADPF Dedicated Downfl ow Three-Speed Air Handler is suitable for use with refrigerants R-410A and R-22. The unit features a check flowrater expansion device and may be

More information

36,000-62,000 BTUH Nominal Capacity

36,000-62,000 BTUH Nominal Capacity 36,000-62,000 BTUH Nominal Capacity STANDARD EQUIPMENT 2TEE3F62A, 4TEE3F62B VARIABLE SPEED AIR HANDLER Ships horizontal - converts to vertical by standing on end. Six-way convertibility-horizontal (left

More information

Savings Without Sacrifice

Savings Without Sacrifice 2013 http://waterheatertimer.org/review-ge-heat-pump-water-heater.html GeoSpring Hybrid Water Heater Savings Without Sacrifice 1 / Did you know that residential water heaters are the highest energy users

More information

NYC Department of Education

NYC Department of Education Asset: A. PHILLIP RANDOLPH HS - MANHATTAN, 443 WEST 135 STREET, New York, 10031 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-02-02 8:11 AM 2018-06-14 1:21 PM Asset Data Are there

More information

Energy Recovery Ventilators

Energy Recovery Ventilators Energy Recovery Ventilators Models ERM, MiniVent, ERV and ERVe Untempered Preconditioners September 2016 Energy Recovery Ventilators Greenheck offers a complete line of energy recovery ventilators to reduce

More information

VariCool VAV Engineering Guide

VariCool VAV Engineering Guide Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control

More information

The ultimate fresh air solution.

The ultimate fresh air solution. Fresh Access The ultimate fresh air solution. Introducing Fresh Access TM. Expertly designed, our innovative energy recovery ventilator (ERV) unit, split dedicated outside air system (DOAS), and packaged

More information

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE COOLING-ONLY 100% OUTSIDE AIR VERSION Telephone:

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE COOLING-ONLY 100% OUTSIDE AIR VERSION Telephone: ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE COOLING-ONLY 100% OUTSIDE AIR VERSION 2.0 www.addison-hvac.com Telephone: +1.407.292.4400 1 SEQUENCE OF OPERATION The ALC controller is turned on

More information

Table of Contents. List of Figures and Tables. Executive Summary: 3 ASHRAE Standard 62.1 Section 6 Analysis 7

Table of Contents. List of Figures and Tables. Executive Summary: 3 ASHRAE Standard 62.1 Section 6 Analysis 7 Army Reserve Center Newport, Rhode Island Technical Report One: ASHRAE Standard 62.1 Ventilat tion and Standard 90.1 Energy Design Evaluations October 4, 2010 2 Table of Contents Executive Summary: 3 ASHRAE

More information

NYC Department of Education

NYC Department of Education Asset: P.S. 160 - BROOKLYN, 5105 FORT HAMILTON PARKWAY, New York, 11219 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-04-03 8:01 AM 2018-05-18 1:45 PM Asset Data Are there fuel

More information

NYC Department of Education

NYC Department of Education Asset: LIBERTY HS - MANHATTAN, 250 WEST 18 STREET, New York, 10011 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-01-29 11:32 AM 2018-02-01 10:16 AM Asset Data Are there fuel tanks?

More information

An efficient solution for more comfortable environments

An efficient solution for more comfortable environments ROOFTOP AHU AIR CONDITIONERS PACKAGE AIR CONDITIONERS An efficient solution for more comfortable environments Grande Rooftop Package Air Conditioners With R410A (50HZ) ROOF TOP PACKAGE AIR CONDITIONERS

More information

UHKA. Air Handlers. Parts List 02-June-2015

UHKA. Air Handlers. Parts List 02-June-2015 Parts List This parts list is current as of the above revision date. See http://www.rheempartslists.net/92-42801-.pdf for the current revision. Air Handlers Table of Contents Model Explanation...................................................................................................................

More information

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS* TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling

More information

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps

Product Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps Product Data OMNIZONE 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons omnizonebwlogo 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE

More information

ELECTRICAL QUANTITY WEIGHT (LB)

ELECTRICAL QUANTITY WEIGHT (LB) VRF SYSTEM INDOOR UNIT ENTERING AIR TEMPERATURES ( F) CAPACITIES (kbtuh) Max SOUND ELECTRICAL WEIGHT TOSHIBA-CARRIER COOLING HEATING Airflow PRESSURE, MARK NO. TYPE ROOM TOTAL SENSIBLE HEATING V / Ø /

More information

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E Replacement Parts List No. 700008400 Revision V 04/2018 McQuay Maverick II Commercial Packaged Rooftop Cooling and Heating MPS 030, 035, 040, 050 Vintage A, E To find your Daikin Applied parts distributor,

More information

NYC Department of Education

NYC Department of Education Asset: MID MAN ADULT LRNG CTR (81) - M, 212 W 120TH ST, New York, 10027 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2018-01-17 8:16 AM 2018-01-17 8:17 PM Asset Data Are there fuel

More information

MARVAIR SCHOLAR III HEAT PUMPS & AIR CONDITIONERS MODELS VAIA & VAISA EXPLODED VIEW PARTS ID

MARVAIR SCHOLAR III HEAT PUMPS & AIR CONDITIONERS MODELS VAIA & VAISA EXPLODED VIEW PARTS ID CABINET SHEET METAL (OUTER PANELS) 1 CABINET SHEET METAL (OUTER PANELS) 1 2 Left Side Door, Includes Exterior Panel and Perforated Interior Panel Right Side Door, Includes Exterior Panel and Perforated

More information

PBS observed paint chips in the garden, which is located approximately six to 10 feet from painted surfaces that were in intact condition.

PBS observed paint chips in the garden, which is located approximately six to 10 feet from painted surfaces that were in intact condition. December 30, 2016 Courtney Wilton Portland Public Schools 501 North Dixon Portland, OR 97227 Via email: Regarding: cwilton@pps.net Lead Paint Condition Assessment Arleta Elementary School 5109 SE 66th

More information

NYC Department of Education

NYC Department of Education Asset: I.S. 45 - BRONX, 2502 LORILLARD PLACE, New York, 10458 Inspection Id Inspection Type Time In Last Edited ME : Mechanical 2017-12-05 9:14 AM 2017-12-20 11:42 AM Asset Data Are there fuel tanks? Total

More information

VAC1 Series-Division 2 / Zone 2

VAC1 Series-Division 2 / Zone 2 VAC1 Series-Division 2 / Zone 2 Wall Mount Explosion Proof Air Conditioner System CSA Certified For Use in Division 2 Hazardous Locations 60 Hertz s 21,200 59,000 60 Hertz, High Ambient, & Custom Designs

More information

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C)

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS DESCRIPTION FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS FEATURE MODELS: AVG24 THRU 60*(C) TEHNIAL UIDE SINLE PIEE VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT-SYSTEM OOLIN & HEAT PUMPS MODELS: AV24 THRU 60*() DESRIPTION The Air Handler line offers the ultimate in comfort, sound and application

More information

CeilMate. Ceiling Mounted Units. Series 1 to 3 tons of cooling capacity

CeilMate. Ceiling Mounted Units. Series 1 to 3 tons of cooling capacity A e r o S y s I n c o r p o r a t e d Ceiling Mounted Units CeilMate Series 1 to 3 tons of cooling capacity Air Cooled, Self-Contained Water Cooled Glycol Cooled Remote Air Cooled Condenser Air Handler

More information

LARGE CAPACITY HEATERS

LARGE CAPACITY HEATERS 250 1,000 Capacities 7.5-12,850 150,000 CFM 200 MBH 250-7,500 MBH - - Tons APPLICATIONS Heating/Cooling/Makeup Air WAREHOUSES / FACTORIES SCHOOLS / UNIVERSITIES COMMERCIAL / RETAIL INDUSTRIAL GYMNASIUMS

More information