VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects
|
|
- Homer Cannon
- 5 years ago
- Views:
Transcription
1 VariCool VAV (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water Unique Solutions for All-Indoor HVAC Projects
2 Water Source Heat Pump Water-Cooled Chilled Water Modular Sections Ideal for Replacement and Renovation Projects The VariCool is a self-contained air conditioning system for use with floor-by-floor cooling applications. The unit addresses concerns for energy efficiency, reliability, sound and IAQ in today s commercial building environment. A single unit can often be used for one tenant or multiple units can be installed for different tenants or redundancy. In addition to numerous standard features, the VariCool system can be tailored with options and special features for your unique application. Hinged, removable doors provide access to the compressors, blowers, motors and controls for maintenance or service. The compressors and condensers with the associated components are located out of the air stream allowing access while the unit is operating. FEATURES 9 to 70 tons Water-Cooled Chilled Water Scroll Compressors Row-Split Evaporator Coils Premium Efficiency Motors Double Sloped SS Drain Pan Hot Gas Bypass (each circuit) Lift Off Hinged Panels Belt Drive Airfoil DWDI Blower Factory Mounted VFD Microprocessor Controls 2
3 Total Installed Cost Advantages Avoid Requirements that Lead to Extra Expense Expensive Equipment, Rigging or Permits Equipment can be shipped in sections Fits easily through standard doors, hallways, and into elevators Minimizes the need for crane rentals, rigging crews, and municipal permits Roofcurbs or Roof Penetration Eliminates expensive curb equipment cost Reduces installation labor Eliminates possible roof water damage Field Piping, Brazing, Evacuation or Charging Factory charged and utilizes Resealable Refrigerant Fittings Reduces installation labor Faster installation and commissioning Excessive Downtime when Replacing Old Systems Sectional shipments accelerate installation Can be installed off-hours and on weekends Shipment can be made to coincide with installation schedules Equipment Damage Due to Weather All equipment is installed indoors Avoids premature replacement costs due to weather wear and/or damage Eliminates downtime due to severe storms Possibility of Theft or Vandalism Eliminates expensive repairs and replacements due to theft and vandalism Enhances building security by eliminating interruption to service Eliminates extra cost for cages and special alarms Field Testing of Installed Product Minimizes field testing as units are functionally tested prior to shipment Reduces labor and speeds installation Assures trouble-free start-ups Outdoor Servicing of Product Outdoor/premium service expense in extreme weather completely eliminated Improves reliability Eliminates roof safety issues Architectural Damage to Building Eliminates expenses for code approvals Requires no rigging holes through building walls Minimizes any type of building alteration Compromise in Performance With Built-to- Order Design Units are built to exact requirements Avoids purchase of excess capacity from standard product offerings Extensive list of configurations and options Major Ductwork or Electrical Modifications Units ordered to closely match existing duct and utility locations Major installation, labor and time savings Exterior Condensing System Eliminates rooftop and pad installation space and cost Water-Cooled and Chilled Water configurations eliminate unsightly equipment outdoors Resealable Refrigerant Fittings Most models feature Resealable Refrigerant Fittings. Unit sections can be shipped split or split in the field without losing the factory charge resulting in no field brazing and a total installed cost advantage. 3
4 Design Features Created for Fast and Easy Installation The VariCool was designed and engineered specifically for fast, trouble free installation in renovation and retrofit applications. The modular knock-down, three piece construction allows easy access through doorways and elevators, preserving the building s architectural integrity. It also eliminates or minimizes unnecessary demolition and construction, saving both time and money. The system has been designed as a floor-by-floor solution. One unit will satisfy the cooling requirements for a single tenant or for partial tenant occupancy. This allows for individual tenant metering. Multiple units can also be installed for higher cooling loads or where system redundancy may be desirable. Because of its small footprint and vertical design, the VariCool requires minimal mechanical room space. Most applications require only single point power and water connections, both entering the cabinet from the top, simplifying utility routing Blower Assembly Plenum blower with pillow block type bearings having an expected life of 200,000 hours. High-Capacity Evaporator Coil Row-split evaporator configuration provides uniform and precise leaving air temperatures under a variety of operating conditions. Refrigeration Module All critical components are located outside the air stream so the unit can be serviced without disturbing the airflow/ performance. 4
5 Tailored for your Unique Application In addition to the numerous standard features, the VariCool system can be tailored with options for your unique application. Operating efficiency can be greatly enhanced with the addition of a water-side or air-side economizer to take advantage of free cooling. Heating options include electric heat, hot water or steam coils. The VariCool has been engineered for operation in locations sensitive to sound and vibration. The blower and motor assembly are spring isolated to minimize any vibration to the unit frame. The 2 thick insulation helps to eliminate any air borne sounds. OPTIONS Painted Cabinets Parallel Direct Drive Fan Systems Lead Circuit Digital Scroll Compressors Hot Water, Steam, or Electric Heat Water Side Economizer Double Wall Construction High Efficiency Filters BMS Interface APPLICATIONS Healthcare Facilities Universities/ Schools High Rise Buildings Office Buildings Commercial / Retail Centers Laboratories Lobbies Conference Rooms 5
6 Nominal Tons (9 to 35) Capacity (a) (MBH) Blower Condenser Weight (b) (Net Operating) Duct Size Dimensions Total Sensible CFM Range Type Co-Axial Co-Axial Co-Axial Co-Axial Co-Axial Co-Axial Co-Axial Co-Axial Working Pressure 400 psig 400psig 400psig 400psig 400psig 400psig 400psig 400psig Evaporator Condensing Blower Assembly Return Air 40 x x 71 Supply Air 18 x x 44 Evaporator 68 H x 68 W x 32 D 80 H x 80 W x 35 D Condensing 30 H x 68 W x 32 D 32 H x 80 W x 35 D Blower 38 H x 68 W x 32 D 48 H x 80 W x 35 D Assembly 68 H x 68 W x 64 D 80 H x 80 W x 70 D Nominal Tons (42 to 70) Capacity (a) (MBH) Blower Condenser Weight (b) (Net Operating) Duct Size Dimensions Total Sensible CFM Range Type Co-Axial Co-Axial Co-Axial Co-Axial Co-Axial Co-Axial Co-Axial Working Pressure 400 psig 400psig 400psig 400psig 400psig 400psig 400psig Evaporator Condensing Blower Assembly Return Air 81 x 86 Supply Air 30 x 52 Evaporator Condensing Blower Assembly 98 H x 100 W x 35 D 36 H x 100 W x 52 D 62 H x 100 W x 52 D 98 H x 100 W x 87 D (a) Capacity based on 80 F DB / 67 F WB with 85 F EFT and 3GPM / Ton (b) Basic unit only. Options add weight. 6
7 THE LENKIN COMPANY MANAGEMENT Case Study WASHINGTON, DC The Challenge In 2011 the need to update the HVAC systems at 1133 Connecticut Ave. became critical. After years of repair they were facing a major challenge. How do we replace existing units with walls and doors built around the old equipment? Standard doorways, tight hallways and service elevators lead contractors and building staff to believe it was near impossible The Solution United CoolAir was able to make dimensional changes to our modular VariCool unit to fit through all doorways, thru down hallways and fit into the elevator, all while holding the factory charge. No brazing on-site required for weekend change-out to not disturb occupied space. Total Installed Cost Advantage Eliminates the need for Expensive Equipment, Rigging, or Permits Avoids Rooftop or Roof Penetration There is no Field Piping, Brazing, Evacuation, or Charging Required Lessens Excessive Downtime when Replacing Old Systems Does Not Require Architectural Damage to Building Will Not Compromise in Performance with Built-To-Order Design Weather will Not Damage Equipment Reduces the Possibility of Theft or Vandalism Refrain from Field Testing of Installed Product Visit or call the factory at for more information 7
8 Unique Solutions for All-Indoor HVAC Projects VertiCool Classic Vertical, 3-30 Ton VertiCool Aurora Vertical, 3-35 Tons Portable Cooling and Heating Units 3-30 Tons Authorized Distributor: C13-Series Horizontal 2-10 Tons VariCool VAV, 9-70 Tons VariCool EZ-Fit VAV, Tons C-Series Horizontal 1-15 Tons Special Configuration Engineered to Order Alpha Aire CFM OmegaAir Horizontal and Vertical 100% Outside Air CFM LIMITED WARRANTY United CoolAir Units are backed by a 1 year limited warranty on parts and a 5 year limited warranty on the compressor (labor not included). Maintenance items such as filters and belts are excluded under this limited warranty. FACTORY TESTED All units are functionally run tested before shipment to ensure a trouble-free start-up and unit commissioning. Industry proven components are used throughout to enhance system reliability and peace of mind. Scan to learn more about all of our products! 491 East Princess Street, York, PA Phone: Fax: uca@unitedcoolair.com web: Copyright by United CoolAir Corporation All rights reserved. Manufacturer reserves the right to make changes without notice SB (0917)
VariCool EZ-Fit 12 to 70 Tons Variable Air Volume Water-Cooled Water Source Heat Pump Chilled Water
VariCool EZ-Fit 12 to 70 Tons Variable Air Volume Water-Cooled Water Source Heat Pump Chilled Water Unique Solutions for All-Indoor HVAC Projects VariCool EZ-Fit Water-Cooled Chilled Water Modular Floor-by-Floor
More informationVertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser
VertiCool Space Saver 2 to 15 Tons Water-Cooled and Chilled Water Air-Cooled w/remote Condenser Unique Solutions for All-Indoor HVAC Projects Water-Cooled Chilled Water Your Choice for Limited Space Applications
More informationC-Series. Unique Solutions for All-Indoor HVAC Projects
C-Series 1 to 15 tons Horizontal Self-Contained or Split Systems Water-Cooled, Chilled Water, Water Source Heat Pump or MagnaCool Precision Cooling Package Unique Solutions for All-Indoor HVAC Projects
More informationMiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water
MiniCool Ductless Split A/C Systems 1 9 Tons Single or Multi-Compressor Circuits Air-Cooled, Water-Cooled, and Chilled Water Unique Solutions for All-Indoor HVAC Projects MiniCool United CoolAir Breaks
More informationVariCool EZ-Fit. Unique Solutions for All-Indoor HVAC Projects
VariCool EZ-Fit 12 to 90 Tons Variable Air Volume Water-Cooled Water Source Heat Pump Chilled Water DOAS (Dedicated Outdoor Air System) Air-Cooled with Remote Condenser Unique Solutions for All-Indoor
More informationCoolSpot. Unique Solutions for All-Indoor HVAC Projects
CoolSpot 1-3 Tons Cooling Capacity Ductless Ceiling Grid Self-Contained Air Conditioning Systems or split Systems Air-Cooled, Water-Cooled, Chilled Water or Magna Cool Precision Cooling Package Unique
More informationVariCool VAV Engineering Guide
Engineering Guide Effective September 2017 Water-Cooled and Chilled Water, Variable Air Volume Contents Product Features... 3 UNIT FEATURES... 3 Product Features... 4 Marvel Plus Microprocessor Control
More informationC13-Series. Unique Solutions for All-Indoor HVAC Projects
C13-Series 2 to 10 Tons Horizontal Self-Contained or Split Systems Air-Cooled, Water-Cooled, Chilled Water, Water Source Heat Pump, Air Source Heat Pump Unique Solutions for All-Indoor HVAC Projects C13-Series
More informationCoolSpot Engineering Guide
Engineering Guide Effective December 2017 Air-Cooled, Water-Cooled, Chilled Water or Magna Cool Precision Cooling Package Contents Contents....................................................... 2 Product
More informationVertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump
VertiCool CLASSIC Engineering Guide Effective March 2018 Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump Contents Product Features... 3 UNIT FEATURES... 3 OPTIONS:... 3 Physical Data...
More informationOmegaAir. 100% Dedicated Outside Air System (DOAS)
OmegaAir 100% Dedicated Outside Air System (DOAS) 1 to 15 Tons Vertical or Horizontal 150 to,000 CFM Water-Cooled Air-Cooled with Indoor Condenser or Optional Outdoor Condenser 2 to 70 kw Electric Heat-Single
More informationAlpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery
Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery All Indoor Installation One Size Fits All 100 to 500 CFM Air-Source Heat Pump Variable Air Volume Air-Cooled Self Contained
More informationAlpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018
Alpha Aire Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery Engineering Guide Effective February 018 CONTENTS PRODUCT FEATURES.......................... OPTIONS.....................................
More informationModular Indoor Systems For Effective Environmental Control
Modular Indoor Systems For Effective Environmental Control Alpha Aire OmegaAir C13-Series VertiCool Aurora VertiCool Classic VariCool EZ-Fit VariCool Renovator VariCool VAV Portable Cooling and Heating
More informationVertiCool Aurora Engineering Guide
Engineering Guide Effective August 2016 Air-Cooled, Water-Cooled and Water Source Heat Pump Contents Product Features... 3 Options... 4 Physical Data...5-6 Air-Cooled Performance Data (a) (b) (c)...7-8
More informationHeat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:
Heat Pumps SA SERIES SA Series Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features: Vertical self-contained units with capacities from 23 70 tons Direct drive backward curved plenum
More informationVERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons
491 East Princess Street York, PA 17403 877-905-1111 717-843-4311 Fax: 717-854-4462 uca@unitedcoolair.com www.unitedcoolair.com VERTICOOL TECHNICAL DATA MANUAL Vertical Air/Water Cooled 3-25 Tons UNITED
More informationHeat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:
Heat Pumps SA SERIES Features: Vertical self-contained units with capacities from 23 70 tons Direct drive backward curved plenum and reduced maintenance Double wall rigid polyurethane foam injected panel
More informationC13-Series Engineering Guide
Engineering Guide Effective January 2018 Horizontal Air-Cooled, Water-Cooled, Chilled Water and Heat Pump Contents Product Features............................... 3 Product Options................................
More informationThe Centurion Rooftop GAS/ELECTRIC, TONS ELECTRIC/ELECTRIC, TONS
48/50HG HIGH-EFFICIENCY SERIES The Centurion Rooftop GAS/ELECTRIC, 12.5 25 TONS ELECTRIC/ELECTRIC, 12.5 25 TONS INDUSTRY-LEADING EFFICIENCY PLUS ADVANCED COMFORTLINK CONTROLS Advanced IAQ features that
More informationSPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS
036-21096-001 (0101) SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The
More informationCHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS
550.23-TG5Y (893) CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L2EU240 20 NOMINAL TONS DESCRIPTION This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility.
More informationTECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 can be
More informationEMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons
560.20-TG1Y (388) EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons Each circuit includes a fully hermetic compressor with a crankcase
More informationTechnical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307
DESCRIPTION Technical Guide CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) This 20 ton evaporator blower is designed with two distinct modules to provide maximum application
More informationVERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled
FORM 145.05-EG1 (1004) VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU 10 105 Ton Water-Cooled Table of Contents FORM 145.05-EG1 (0804) Features and Benefits.....................................................
More informationSeries. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:
RL Packaged Rooftop Units, heat pumps and Outdoor air handling Units Features: Air-cooled condenser, water-cooled condenser, or patented AAON evaporative-cooled condenser, with capacities from 45-240 tons
More informationHeat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:
Heat Pumps M2 SERIES Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features: Water-source and geothermal heat pump self-contained units with capacities from 3-70 tons 10%-100% variable
More informationTECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811
Description These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of Refrigerant R-410A for storage
More informationRN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.
RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities
More informationFlexible & Innovative. Cooling Solutions
Flexible & Innovative Cooling Solutions Flexible & Innovative Compu-Aire Inc. offers a variety of high performance precision cooling systems that can adapt to your application needs. With today s rapidly
More informationSeries PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:
RZ PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS Features: Air-cooled condenser, water-cooled condenser, or evaporative-cooled condenser packaged rooftop units from 55-240 tons Water-source
More informationRooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating
Rooftop Ventilator with Packaged Cooling & Heating Models RV and RVE Institutional Commercial Industrial 800-1,500 cfm.0 in. wg External Static Pressure Indirect Gas, Hot Water, Electric Heating Packaged
More informationSKYPAK II, 3 Ton Series, gives you a
SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall
More informationSystem Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.
System Components with ` Emphasis on Packaged Rooftop Application and Installation Jerry Cohen President Jacco & Assoc. Agenda Define and relate in practical terms the following components: System Effect
More informationPlenum Fans. Model HPA. Direct Drive
Plenum Fans Model HPA Direct Drive October 2012 Quiet & Efficient HPA Plenum Fans Greenheck s modular plenum fan, model HPA, is designed and engineered to provide superior performance and reliability in
More informationTHE ULTIMATE ROOFTOP SOLUTION
Configured Packaged Rooftop Solutions Specializing in Dedicated Outdoor Air Systems (DOAS) Capacities from 6 to 90 Tons Available in 208, 230, 460 and 575 Volts THE ULTIMATE ROOFTOP SOLUTION Service Friendly
More informationPACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.
RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities
More informationMODULE-AIRE VERTICAL PACKAGE UNITS MB SERIES MB SERIES. Energy Wise HVAC Equipment
Energy Wise HVAC Equipment FHP MANUFACTURING 601 N.W. 65th Court Fort Lauderdale, FL 33309 (954) 776-5471 (800) 776-5529 Fax www.fhp-mfg.com VERTICAL PACKAGE UNITS MODULE-AIRE FHP brings to the market
More informationSECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15732 - PACKAGED ROOFTOP AIR CONDITIONING UNITS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Package roof top unit. B. Heat exchanger. C. Refrigeration components. D. Unit operating controls. E. Roof
More informationSKYPAK II, 3 Ton Series, gives you a
SKYPAK II 3 ton Heating And Cooling self-contained Package SKYPAK II, 3 Ton Series, gives you a complete air-conditioning and heating system as an all in one package unit. Designed for convenient through-the-wall
More information62DA,DB,DC,DD,DE,DF07-38
62D-3SB 62DA,DB,DC,DD,DE,DF07-38 DEDICATED VERTICAL OR HORIZONTAL 100% OUTDOOR AIR UNIT PERFORMANCE DATA UNIT DIMENSION PRINTS ACCESSORY DIMENSION PRINTS Copyright 2011 Carrier Corporation Syracuse, New
More informationHeat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:
Heat Pumps SB SERIES SB Series Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features: Vertical self-contained units with capacities from 3-18 tons ECM driven direct drive backward curved
More informationRoofPak Applied Rooftop Systems
RoofPak Applied Rooftop Systems RoofPak Applied Rooftop Systems Design flexibility, energy efficiency, system performance and reliability make Daikin RoofPak applied rooftop systems the ideal solution
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)
DESCRIPTION These units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging. Each unit is pressurized with a holding charge of refrigerant-22 for storage
More informationHeat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:
Heat Pumps SB SERIES Features: Vertical self-contained units with capacities from 3-18 tons ECM driven direct drive backward curved plenum supply fans for improved energy Double wall rigid polyurethane
More informationPoolPak MPK Series. PoolPak.com. Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS
PoolPak MPK Series Environmental Control Systems REDUCED FOOTPRINT & WEIGHT COMPARED TO EARLIER GENERATIONS PoolPak.com The PoolPak MPK Series Built using the PoolPak Proven Approach SM, the MPK Series
More informationK*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*
TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS K*ES120 10 NOMINAL TONS EER 8.5 DESCRIPTION These completely assembled dual circuit evaporator blower units include a well-insulated cabinet, a DX cooling
More informationVision and Skyline Semi-custom Air Handlers
Vision and Skyline Semi-custom Air Handlers Flexible design solutions to match building applications Skyline Outdoor Air Handler 900 to 65,000 cfm Vision Indoor Air Handler 900 to 100,000 cfm Custom solutions
More informationDX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM
D Units Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM INDUSTRY-LEADING HVAC MANUFACTURER Nortek Air Solutions is the largest custom HVAC manufacturer in North America, with a combined total of
More informationTECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL The LA/LB line is a flexible performer. LA300, LB360 & 480 canbepositionedinupto12differentpositionsandsuspended
More informationALL PRODUCTS BROCHURE
ALL PRODUCTS BROCHURE www.aaon.com d e d i c at i o n t o cust o m e r service since the founding of aaon in 1988, we have maintained our commitment to design, develop, manufacture and deliver heating
More information1080 Marina Village Parkway, Suite 501 Alameda, CA (510) Fax (510) HVAC DESIGN INTENT
Taylor Engineering 1080 Marina Village Parkway, Suite 501 Alameda, CA 94501-1142 (510) 749-9135 Fax (510) 749-9136 LLC HVAC DESIGN INTENT PART 1 - GENERAL 1.1 Overview A. The project consists of a 3-story
More informationModular Supply Make-Up Air Unit
Modular Supply Make-Up Air Unit Model MSX Flexible Design Factory Assembled Heating Options Hot Water Steam Electric Cooling Options Evaporative Direct Expansion Chilled Water November 2009 Product Features
More informationCOMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units
COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units Technical Development Program Technical Development Programs (TDP) are modules of technical training on HVAC theory, system design, equipment selection
More informationWater-Cooled Self-Contained Units
CATALOG FORM SK145.15-EG1 (1017) Water-Cooled Self-Contained Units C-Series, Vertical Nomenclature WATER-COOLED SELF-CONTAINED UNIT 1, 2 3 4, 5, 6 7 8 9 10 11 12 13 14 15 16 17 CS V 180 B 2 M 1 V A A A
More informationHORIZONTAL SERIES. AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h
AIRPAC HORIZONTAL PACKAGED SERIES 24,000 to 180,000 BTU/h HORIZONTAL SERIES MiniPac HU024, HU036, HU048, HU060 DualPac HU072, HU096 MaxPac HU120, HU144, HU180 Horizontal packaged selfcontained, air cooled
More informationThe ultimate fresh air solution.
Fresh Access The ultimate fresh air solution. Introducing Fresh Access TM. Expertly designed, our innovative energy recovery ventilator (ERV) unit, split dedicated outside air system (DOAS), and packaged
More informationDirect Gas-Fired Make-Up Air Models DG and DGX
Direct Gas-Fired Make-Up Air Models DG and DGX Commercial, Industrial and Kitchen Applications 800-48,000 cfm 4 in. wg External Static Pressure Direct Gas-Fired Heating Optional Cooling - Packaged DX (2.5
More informationProduct Data. Features/Benefits. OMNIZONE 50BV Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps
Product Data OMNIZONE 50BV020-064 Remote Air-Cooled and Water-Cooled Indoor Self-Contained Systems and Water Source Heat Pumps 18 to 60 Nominal Tons omnizonebwlogo 50BVC,E,J,K,Q020-034 SINGLE PIECE OMNIZONE
More informationSubmittal Data Performance Data Electrical Data
ERMS Series Submittal Data Submittal Data Unit Designation: Job name: Architect: Engineer: Contractor: Performance Data Revision: 07/01/11 Cooling Capacity: EER: Heating Capacity: COP: Ambient Air Temp:
More informationSPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED
(491) SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU, K3EU & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper tubes
More informationENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
More information"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS
"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS Belt Driven Self-Contained Packages Vertical and Horizontal Configuration Size 6-8-10 Ton Capacities Spinnaker Industries Inc. SWHP /
More informationADDENDUM 1. Southeast High School Auditorium & Gymnasium HVAC Improvements
ADDENDUM 1 CLIENT: PROJECT: TO: FROM: Guilford County Schools (GCS) Southeast High School Auditorium & Gymnasium HVAC Improvements All Prospective Bidders Derrick Giles, SAMR, PLLC. DATE: 6/6/2018 The
More informationBrown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS
SECTION 23 70 00 AIR HANDLING UNITS PART 1. GENERAL 1.1 Section includes air-handling units to 15,000 cfm and accessories. 1.2 Related Sections 1 : A. Division 01 - Brown University Standard for Narragansett
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
Single Package Rooftop Gas Heating/Electric Cooling Unit Two Stage Cooling Capacity Control with Puronr (R---410A) Refrigerant Sizes: 17, 20, 24, 28, 30 Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION
More informationProduct Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)
Product Data 38AH024-134 Commercial Air-Cooled Condensing Units 50/60 Hz 20 to 130 Nominal Tons (63 to 390 Nominal kw) a38-4143ef 38AH044-134 These dependable split systems match Carrier s 40RM or 39 Series
More informationSubmittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS
AutoZone R Model Single Package Rooftop Gas Heating/Electric Cooling Unit Size 07 with Puronr (R---410A) Refrigerant Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION
More informationHVAC 101. H V A C S y s t e m s
H V A C 1 0 1 S y s t e m s Introduction & Overview Should you care? Mechanical System Types Components & operation Popular Application Key Issues and Design Considerations System Comparisons First Cost
More information50TM TFF COMBINATION HEATING/COOLING UNITS
50T-1SB 50TM007-012 50TFF004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York
More informationLiebert Mini-Mate2 1 To 8 Tons
Liebert Mini-Mate2 1 To Overhead Precision Cooling And Humidity Control Precision Cooling For Business-Critical Continuity Precision Cooling In A Space-Saving, Ceiling-Installed System When IT equipment
More informationLGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.
Service Literature The LGH/LCH high and standard efficiency 5, 0, 5 and 50 ton (, 0.7, 58. and 75.9 kw) units, are configure to order units (CTO) with a wide selection of factory installed options. The
More informationTECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:
GENERAL SPECIFICATIONS OUTDOOR UNIT: TECHNICAL GUIDE COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM MODELS HB 180 & HB 240 MODELS LB 180 & LB 240 15 & 20 NOMINAL TONS 9.7 EER Two independent refrigerant
More information50TM COMBINATION HEATING/COOLING UNITS
50TM-1SB 50TM004-014 COMBINATION HEATING/COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2002 Carrier Corporation Syracuse, New York 13221 Form
More information48TM GAS HEATING/ELECTRIC COOLING UNITS
48TM-4SB 48TM004-014 GAS HEATING/ELECTRIC COOLING UNITS PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS Copyright 2005 Carrier Corporation Syracuse, New York 13221 Form
More informationSplit System Heat Pumps
Split System Heat Pumps Split System Heat Pumps 7 1/2-20 Tons - 60 Hz Air Handlers 5-20 Tons - 60 Hz SSP-PRC001-EN Introduction Split System Heat Pump Units... Designed With Your Needs In Mind. The Trane
More informationBOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:
4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XRT INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This
More informationTECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703
TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 DESCRIPTION These Sunline 2000 units are completely assembled, piped and wired at the factory to provide one-piece shipment and rigging.
More informationLiebert Mini-Mate2 1 To 8 Tons
Liebert Mini-Mate2 1 To Overhead Precision Cooling And Humidity Control Precision Cooling For Business-Critical Continuity Precision Cooling In A Space-Saving, Ceiling-Installed System When IT equipment
More informationMC SERIES. Optional reverse cycle heating Takes full advantage of building diversity
FHP brings to the market a first in R-410A large capacity modular reverse cycle units. The many features and energy efficiency of the MC Series make them the ideal choice for either new construction or
More informationUNIVERSITY OF MISSOURI Central Station Air-Handling Units March
GENERAL: 1. This section provides criteria for the design and installation of air handling units. DESIGN GUIDELINES: Design General 1. Location 1.1. For new construction, and existing buildings where possible,
More informationControl Systems. Design & Manufacturing. Eco-Friendly. High Performance
Temperature & Humidity Control Systems Design & Manufacturing DX Air / Water / Glycol Cooled Air and Water Side Economizer Chilled Water Systems Eco-Friendly High Performance OPTIMAL COOLING SOLUTIONS
More informationTechnical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)
Technical Guide SUNLINE 2000 SPLIT-SYSTEM EVAPORATOR BLOWER K4EU180 15 NOMINAL TONS (WORLD 50 HZ) DESCRIPTION These completely assembled units include a well-insulated cabinet, a DX cooling coil with copper
More informationComplete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A
Publication No. WT-CSX-0616A Central Station Air Handling Units Complete HVAC Capability Horizontal Draw-Thru to Size 65 Vertical Draw-Thru to Size 50 1000 to 60,000 CFM Forward Curved or Airfoil Wheels
More informationGuide Specifications PART 1 GENERAL 1.01 SUMMARY
Guide Specifications PART 1 GENERAL 1.01 SUMMARY A The environmental control system shall be designed specifically for precision temperature control applications. It will automatically monitor and control
More informationComplete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks
Ventilation Heat Recovery PoolPak International Maintaining Your Climate for Indoor Pools and Waterparks Complete Ventilation, Heat Recovery and Dehumidification Packaged System by PoolPak International
More informationInnovent s. Direct Replacement Program. Engineered to match... your footprint, your needs.
Innovent s Direct Replacement Program Engineered to match... your footprint, your needs. Is it time to replace your commercial air handlers? Then it s time to look into Innovent s Direct Replacement Program.
More informationSKYPAK II Heating & Cooling Self Contained Packages
SKYPAK II Heating & Cooling Self Contained Packages SKYPAK II gives you a complete airconditioning and heating system as an all-in-one package unit. Designed for conventional through-the-wall installation
More informationNew Product Offering AIR HANDLERS ADVANCING THE SCIENCE OF AIR DISTRIBUTION. Redefine your comfort zone.
New Product Offering AIR HANDLERS ADVANCING THE SCIENCE OF AIR DISTRIBUTION Rethink what air management systems can be. Revise your notion of functionality. Redefine your comfort zone. Our Legacy Since
More informationCB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:
CB/CF CONDENSERS AND CONDENSING UNITS CF CB Features: 2-70 ton air-cooled condensing units and remote air-cooled condensers Air-source heat pump configurations for energy efficient heating Variable capacity
More informationThe Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma
Objectives and Requirements For the Creative and Performing Arts High School (CAPA), the main objective of the mechanical design is to provide an energy efficient system that is easily maintainable and
More information50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT
50HJQ-11SB 50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION
More informationD-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency
Digital Precise Air Control System D-PAC Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency AAON 24 South Yukon Avenue Tulsa, Oklahoma 747 (918) 583-2266 Fax (918)
More informationDESIGN GUIDELINES SECTION HVAC
3/15/17 Cooling Methodology Chiller Plants Configurations monitoring Preferred DESIGN GUIDELINES SECTION 15700 HVAC Air-cooled chillers < or = 300 tons; water-cooled chillers > 300 tons Variable volume
More information1.1 This section applies to air handling units for HVAC Systems.
AIR HANDLING UNITS GENERAL INFORMATION 1.1 This section applies to air handling units for HVAC Systems. DESIGN REQUIREMENTS 2.1 Design Criteria a. The decision to use modular central station air handling
More informationSubmittal Summary Page
ate 05/24/2011 Project Name ouglas Middle School Project Number Client / Purchaser Submittal Summary Page Qty Tag # Model # escription 1 RTU- Cafeteria 15 Ton, Johnson Controls Series 20 Single Packaged
More informationProduct Line Card. Daikin Applied HVAC system solutions. Advanced technology and solutions from the world s leading innovator in HVAC.
Product Line Card Daikin Applied HVAC system solutions Advanced technology and solutions from the world s leading innovator in HVAC. As the world s leading air conditioning company, we believe your air
More informationGuide Specifications for InRow Direct Expansion
Guide Specifications Guide Specifications for InRow Direct Expansion THIS GUIDE SPECIFICATION IS WRITTEN IN ACCORDANCE WITH THE CONSTRUCTION SPECIFICATIONS INSTITUTE (CSI) MASTERFORMAT. THIS SECTION MUST
More informationSeries. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost
LL Chillers and Outdoor Mechanical Rooms Air-Cooled Features: Air-cooled condenser chillers with capacities from 35-345 tons Evaporative-cooled condenser chillers with capacities from 35-540 tons Variable
More information