LMV Series W Low Profile - Medium Base

Similar documents
DMV Series W For Combustible Dusts

N2MVF Series Compact Fluorescent

EVLPF Series Compact Fluorescent

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

50-175W VMV Series Champ H.I.D. Luminaires

UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating

Table 500-3(d) Identification Numbers. Maximum Identification

Applications. Standard Materials

Champ-Pak Wall Pack Luminares

VAPORGARD Incandescent Luminaires

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Champ-Pak TM Wall Pack & Floodlight Luminaires Hazardous and Non-Hazardous

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

HID lighting for hazardous areas Champ HID floodlighting. Champ floodlights. HID floodlighting for hazardous areas

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

EJB Custom-Built Control Panels

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

REFRACTOPACK. Corrosion resistant construction allows this luminaire to be installed in corrosive and marine outdoor applications.

50W Explosion Proof LED Light - C1D2, C2D1 - Replacement for 150W Metal Halide - Globe/Guard

CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X

COMPACT SIZE INTRODUCTION & LOGIC

An Eaton Intelligent Power solution. Champ VMV Connected lighting for hazardous areas

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

EXH Series Explosionproof Electric Air Heaters

REDUCED PROFILE INTRODUCTION

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Lighting for Hazardous & Severe Environments

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

V2LCHF2UNV1 Led Lumnr. Features. Material, Color, and Finish. Long Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN

UTILITY LIGHT INTRODUCTION

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

Arlington. Full Cutoff. Utility Series

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

Choice of factory set distributions. Thermally set white polyester powder paint. Optional wet location listing

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

High Mast Series HMAO HMSC

Full Cutoff. Utility Series

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

LED hazardous lighting catalog

Rating. Class I Div II

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

Capella 2. Project Name. Construction. Optical System. Product Applications. Housing and lens frame are constructed from heavy-duty low

PANELBOARD PROTECTION ON A GLOBAL SCALE

POLESTAR II SERIES HL /01

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

HL-2449_flg:8 pager 6/17/10 11:19 AM Page 1 Tear Drop LED Series

Post Top Full Cutoff HID

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

POINT ROLLOVER LIGHTS PRL LED HELIDECK SEMIFLUSH LIGHT

SIMPLIFIED LIGHTING. TRUSTED PROTECTION. CODE MASTER LED LUMINAIRES CLASS I, DIVISION 1

POINT HELIDECK LIGHTS PRL-EX-LSM LED v4 CLASS I, DIVISION 2 & ZONE 2

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

MERCMASTER LED SERIES

E THANOL AND B IODIESEL P LANT L IGHTING S OLUTIONS

RE Luminaire HOLOPHANE

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

LED lighting for land-based rigs Pauluhn DLL LED Luminaires. Pauluhn DLL. LED luminaires for land-based drilling

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Hazardous area LED lighting Vaporgard LED Luminaires. Vaporgard LED. Low profi le incandescent replacement

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

120W Explosion Proof Signal Light w/ Audible Alarm - C1D1 - (2) Colored LED Lamps - 55 Horn Tones

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS

150W Explosion Proof LED Flood Light - Surface Mount Lumens - C1D V AC

LED Lighting Solutions Engineered for Demanding Environments Appleton LED Luminaires

DuroSite LED High Bay - UL for Indoor and Outdoor Industrial Applications. Patent Pending

Lighting Solutions. from a Leader in Light Source Technology

Transcription:

L LMV Series 50-150W Low Profile - Medium Base Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence (HPS 5W, 50W) Marine & Wet Locations, R, 4, 4X; IP66 L Applications: LMV series Champ luminaires are used: In applications involving low luminaire mounting heights or restricted mounting space or where luminaire weight is a factor In areas in which ignitible concentrations of flammable gases or vapors will be present only due to abnormal, unusual, or accidental conditions Where combustible dusts are present Where combustible dusts and flammable vapors are present simultaneously In elevated ambient temperatures often found in industrial applications In marine applications where water spray and corrosive atmospheres are considerations Wherever the damaging effects of wind, snow, sleet, or hot sun are found In manufacturing plants, chemical, petrochemical, and other industrial process facilities, waste or sewage treatment facilities, offshore or dockside installations, cold storage facilities, parking garages or wherever dust, dirt, water, vibration and rough usage are a problem Features: Compact, lightweight design is ideal for low mounting heights. Cast copper-free aluminum construction (less than 0.4 of 1% copper) and epoxy powder finish provide excellent resistance to corrosion. Seven mounting arrangements to suit any lighting layout pendant, flexible pendant, ceiling, wall, straight stanchion, angle stanchion, and quad-mount. Wide range of lamp wattages to meet specifiers' needs: 50, 70, 100 and 150 watt (HPS); 70 and 100 watt (MH) medium base lamps. Hinged ballast housing for ease of installation and maintenance. All luminaires designed to perform in a 40 C ambient temperature. Selected luminaires are suitable for ambient temperatures up to 65 C. Superior gasketing seals between the mounting module, housing, and optical assembly for optimum performance in wet and corrosive environments. Hubs with an integral conduit stop and bushing to help prevent damage to field wiring during installation. Low ambient capability to 40 C. Dome and 0 angle reflectors made of bright white Krydon material provide superior reflectivity, with twist-on feature requiring no tools or additional hardware. Will not chip, peel, dent, rust, or corrode. Grounding wire for safety. Medium base lamp sockets. Certifications and Compliances: NEC/CEC: Class I, Division 2, Groups A, B, C, D HPS 5W, 50W Class II, Class III & Simultaneous Presence (Class I, Division 2 and Class II) Class I, Zone 2 IEC: Zone 2 Ex nr IIC UL Standards: 844 Hazardous (Classified) Locations 1598 Luminaires 1598A Marine Locations CSA Standards: C22.2 No. 17 IEC Standards: 60079-15 Standard Materials: Ballast housings and mountings copper-free aluminum (less than 0.4 of 1%) Exterior hardware stainless steel Reflectors (dome and angle) Krydon fiberglass-reinforced polyester material Globes heat and impact resistant, internally fluted glass Guards copper-free aluminum Standard Finishes: Copper-free aluminum epoxy powder coat Krydon material high reflectance white Stainless steel natural Electrical Ratings: 120 volts, dual-tap (120/277), multi-tap* 50, 70, 100, 150 watts HPS** 70 and 100 watts MH * When ordering fuses for luminaires, option S658, you must specify the operating voltage. S658 cannot be ordered with /MT in the catalog number. ** 150W HPS is not avalable with multi tap ballast. 120V only. Options: The following special options are available from the factory by adding suffix to luminaire Cat. No.: Description Suffix Restricted Breathing Construction... S826 Class I, Division 2 & Zone 2 Suitability Cooler Operating Temperatures (T-Numbers) Certified for IEC Zone 2... S826TB Furnished with terminal block, crimp terminals and dedicated voltage ballasts (no MT, DT, or TT) Fused to protect ballast and capacitors against abnormal line conditions... S658* (Not for use in Canada) (Not suitable for marine applications) Quick-Clip - Holds weight of housing when closed. No need to support luminaire while screwing the housing to the cover... S890 Ballast-Gard starter cut-out switch prevents starter pulsing when lamp is cycling or inoperative; prolongs ballast and ignitor life. Available for use with 50 100W HPS only... BG Factory assembled with H.I.D. lamps installed for additional labor savings... FA Stainless steel insert top hat with stainless steel threaded insert to attach ballast housing... S806 Accessories: See pages 1022 102 for complete listing 972 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business

LMV Series 50 150W High Pressure Sodium Low Profile - Medium Base Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Cl. II, Groups E, F, G; Cl. III & Simultaneous Presence (5W, 50W) Marine & Wet Locations, R, 4, 4X; IP66 L To complete the catalog #, include information in notes 1, 2 and below. For guards and other optics see LMV Series - Ordering By Components page. BASIC CATALOG NUMBER Mounting Style Hub Size Watts With G54 Globe and P50 Guard Pendant Mount /4 50 LMVS2A050GP 1 LMVSA050GP /4 70 LMVS2A070GP 1 LMVSA070GP /4 100 LMVS2A100GP 1 LMVSA100GP /4 150 LMVS2A150GP 1 LMVSA150GP Flexible Pendant Mount /4 50 LMVS2HA050GP /4 70 LMVS2HA070GP /4 100 LMVS2HA100GP /4 150 LMVS2HA150GP Ceiling Mount Thru-Feed /4 50 LMVS2C050GP 1 LMVSC050GP /4 70 LMVS2C070GP 1 LMVSC070GP /4 100 LMVS2C100GP 1 LMVSC100GP /4 150 LMVS2C150GP 1 LMVSC150GP Wall Mount Thru-Feed /4 50 LMVS2TW050GP 1 LMVSTW050GP /4 70 LMVS2TW070GP 1 LMVSTW070GP /4 100 LMVS2TW100GP 1 LMVSTW100GP /4 150 LMVS2TW150GP 1 LMVSTW150GP Quad Mount Pendant, Adjustable Thru-Feed, 25 Angle, 12 1 /2 Angle /4 50 LMVS25Q050GP /4 70 LMVS25Q070GP /4 100 LMVS25Q100GP /4 150 LMVS25Q150GP L Stanchion Mount 25 Angle 1 1 /2 50 LMVSJ050GP 1 1 /2 70 LMVSJ070GP 1 1 /2 100 LMVSJ100GP 1 1 /2 150 LMVSJ150GP Stanchion Mount Straight 1 1 /2 50 LMVSP050GP 1 1 /2 70 LMVSP070GP 1 1 /2 100 LMVSP100GP 1 1 /2 150 LMVSP150GP 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts 60Hz NEC/UL CEC/CSA (cul) Voltage Multi Tap Dual Tap 120V 480V Tri Tap Dual Tap 120V Suffix /MT /DT /120 /480 /TT /DT /120 2. 150W HPS Luminaires: For 55V lamps - add suffix LX. 50W HPS luminaire is dual tap only. 150W HPS is not avalable with multi tap ballast. 120V only.. Options - Add the required option suffixes, see page 972, in alpha-numeric order. www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business 97

L LMV Series 70-100W Metal Halide Low Profile - Medium Base Cl. I, Div. 2, Groups A, B, C, D Restricted Breathing Cl. I, Div. 2 & Zone 2 (Suffix S826) Certified for IEC Zone 2 (Suffix S826TB) Marine & Wet Locations, R, 4, 4X; IP66 To complete the catalog #, include information in notes 1, 2 and below. For guards and other optics see LMV Series - Ordering By Components page. Mounting Style Hub Size Watts BASIC CATALOG NUMBER With G54 Globe and P50 Guard Pendant Mount /4 70 LMVM2A070GP 1 LMVMA070GP /4 100 LMVM2A100GP 1 LMVMA100GP Flexible Pendant Mount /4 70 LMVM2HA070GP /4 100 LMVM2HA100GP Ceiling Mount Thru-Feed /4 70 LMVM2C070GP 1 LMVMC070GP /4 100 LMVM2C100GP 1 LMVMC100GP Wall Mount Thru-Feed /4 70 LMVM2TW070GP 1 LMVMTW070GP /4 100 LMVM2TW100GP 1 LMVMTW100GP Stanchion Mount 1 1 /2 70 LMVMJ070GP 25 Angle 1 1 /2 100 LMVMJ100GP L Stanchion Mount 1 1 /2 70 LMVMP070GP Straight 1 1 /2 100 LMVMP100GP 1. Add voltage suffix to end of catalog number Standard Voltage Ballasts 60Hz NEC/UL CEC/CSA (cul) Voltage Multi Tap 120V 480V Tri Tap 120V Suffix /MT /120 /480 /TT /120 2. 70W ballast not available in 480V.. Options - Add the required option suffixes, see page 972, in alpha-numeric order. 974 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business

LMV Series Ordering by Components L LMV luminaires are available in components. A complete luminaire consists of: I. Champ Cover (Mounting Module) II. LMV Ballast Housing Include voltage and required option(s) III. Globe, Guard, Reflector I. Champ Cover (Mounting Module): Type Conduit Cat. # Pendant /4" APM2 1" APM Flexible Pendant /4" HPM2 Ceiling* /4" CM2 1" CM Wall /4" TWM2 1" TWM Stanchion 25 Degree Angle 1 1 /2" JM5 Stanchion Straight 1 1 /2" PM5 Quad-Mount /4" QM25 *Not available with V2PC photocell. II. Ballast Housings: Complete catalog number must have the voltage suffix (MT shown) and any options suffixes. Type Watts Cat. # High Pressure Sodium 50 LMVS050/120 70 LMVS070/MT 100 LMVS100/MT 150 LMVS150/120 LX Metal Halide 70 LMVM070/MT 100 LMVM100/MT III. Globe, Guards and Reflectors: Type Cat. # Globe G54 Globe Guard P50 Reflector Dome RD66 Reflector Angle RA66 L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 2015 Eaton s Crouse-Hinds Business

L LMV Series Family Tree L 976 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business

LMV Series Temperature Performance Data L Rated Ambient C Class I, Division 2 Class II, Division 1 Class I, Zone 2 Globe (G54) w/ or w/o Reflector (RA66 or Globe (G54) w/ or w/o Reflector (RA66 or Restricted Breathing Suffix S826 w/ Factory Sealed Suffix S865 Simultaneous Presence Class I, Div. 2 Supply Wire Suitable Cat. # Wattage Type RD66) Group RD66) Class II, Div. 1 Globe (G24) AEx na nr II for C LMVS50 50 HPS 40 T2D EFG TC T2B T5 T N/A LMVS50 50 HPS 55 T2C T4 T 75 LMVS50 50 HPS 65 T2C T4 T 85 LMVS70 70 HPS 40 T2B T4 T 75 LMVS70 70 HPS 55 T2B T4 T 85 LMVS100 100 HPS 40 T2 T4 T 85 LMVS100 100 HPS 50 T T 90 LMVM70 70 MH 40 T2B T4 T 75 LMVM70 70 MH 55 T2B T4 T 85 LMVM100 100 MH 40 T T 85 LMVM150 150 HPS 40 T1 50 C 85 The Class I, Division 2 T-codes apply to luminaires without the restricted breathing (S826) or factory sealed (S865) options. These luminaires are listed to UL 844. UL 844 specifies how the temperatures are measured. The Class I, Zone 2 T-codes are for luminaires that are additionally listed to UL 60079-15 that specify a different method for measuring temperatures. Since NEC 501.1 states that equipment "...for use in Class I, Zone 0, 1, or 2 locations shall be permitted in Class I, Division 2 locations..." then these luminaires are suitable for Class I, Division 2 but with lower temperature ratings. They also have the advantage of meeting the more rigorous mechanical tests of UL 844. L www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business 977

L LMV Series Dimensions and Weights Dimensions In Inches: Luminaire Net Weights: Luminaire Series Watts Luminaire with Globe, Guard (lbs.) Pendant Mount Wall Mount Top View Ceiling Mount LMVS 50 7 /4 70 8 1 /4 100 8 /4 150 9 1 /4 LMVM 70 9 100 9 Type Lbs. Add for mounting modules: Pendant 1 1 /4 Flexible Pendant 1 1 /2 Ceiling 2 /4 Quad-Mount 1 /2 Wall 4 1 /2 Angle Stanchion 1 /2 Straight Stanchion 4 1 /2 Type lbs. Add for reflectors: Dome 1.0 0 Angle 1.0 Deduct for luminaire without guard: P50 Guard 1 /2 Quad-Mount Luminaire with Globe, Guard, Reflectors L Straight Stanchion Mount 25 Angle Stanchion Mount 978 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business

LMV Series Photometric Data L : 100W/E-17 high pressure sodium (HPS) Total bare lamp lumens: 9500 All data provided is for high pressure sodium luminaires with 100W/E-17 clear lamps. Use conversion factors (multipliers) shown below for other lamp types and wattages. Consult Eaton's Crouse-Hinds for additional photometric data on any Champ Series. Luminaire with Globe and Dome Reflector Multipliers (for use with candela curve only). Conversion Luminaire Series Watts Factor LMVS 5 0.24 50 0.42 70 0.67 150 1.68 Isofootcandle Chart: Luminaire with Globe and Dome Reflector Luminaire spacing ratio: 2.0 Coefficient of Utilization Effective Floor Cavity Reflectance 20% % Reflectance Room Cavity Ratio Eff. Ceil. Wall 1 2 4 5 80 70 50 0 50.722.628.545.47.41 0.691.579.487.408.46 10.66.57.441.58.296 50.705.61.54.46.40 0.676.568.479.40.40 10.650.51.46.55.29 50.671.585.511.442.87 0.647.548.464.90.2 10.627.514.426.49.289 50.641.560.489.424.71 0.62.529.450.79.22 10.605.501.416.42.284 50.614.57.470.407.56 10 0.598.510.46.67.41 10.584.488.407.5.279 0 0.568.471.91.19.26 Isofootcandle Chart: Luminaire with Globe and 0 Angle Reflector L % Reflectance Room Cavity Ratio Eff. Ceil Wall 6 7 8 9 10 80 70 50 0 50.66.24.288.261.226 0.00.259.225.199.165 10.25.215.180.156.127 50.58.18.282.256.221 0.295.255.22.196.165 10.249.212.179.156.126 50.4.05.271.246.214 0.288.248.217.192.161 10.246.209.177.154.124 50.0.292.261.27.206 0.280.24.210.186.157 10.242.205.175.152.122 50.17.282.251.228.199 10 0.272.27.206.182.152 10.28.202.172.149.120 0 0.22.187.158.16.107 Isofootcandle charts show illumination in footcandles on work plane 10 feet below light center. Multiply by factor shown to convert to other mounting heights. Height (Ft.) Factor Height (Ft.) Factor 6 2.78 14 0.51 8 1.56 16 0.9 12 0.70 www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright 201 Eaton s Crouse-Hinds Business 979