Emergency Lighting. Product Guide LED. The right source for the. right light

Similar documents
LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

Bdl60u Fluorescent Emergency Ballast

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

LED RETROFIT SOLUTIONS

HIGH BAY APPLICATIONS

FET22 (2x2) 25W & 40W Series

The New Lux-Ray LED Emergency Lighting

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

PSO Business Rebates Retrofit Lighting Technical Requirements

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

Selecting And Applying Emergency Lighting Systems

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

NYC Approved Product Series

Nightfall. led emergency egress lighting

CDL8 LED Architectural

Emergency TLED Lighting Retrofit 101. December 6 th 2017

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

FHSAC1-UNV-40L INSTALLATION INSTRUCTIONS

2018 Instant Lighting Rebates Product Catalog

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

THE HIGH STRIP FIXTURE SERIES PERFORMANCE KEY FEATURES INCLUDE: LED Fixture Series for General, Direct and Indirect Illumination

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

Exit/Emergency Lighting Guide

Catalog Number. Notes

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

Selecting & Applying Emergency Lighting Systems

LED Linear Design Highlights

Explosion Proof Exit Sign - Class I, Division I - IP65-120V/277VAC - Emergency Battery Back-Up

LED RETROFIT CONVERSION KITS

PRODUCT DATA SHEET LIGHTING PRODUCTS

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

SECTION LIGHTING

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

TERRALUX RETROFIT LED LIGHTING

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Spectron LSN (Life Safety Network) Suggested Specifications

Dimensions (111mm) (111mm) 3 (76mm)

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

Pacific Gas and Electric Company Energy Efficiency Rebates for Your Business. Lighting Rebate Catalog Saving energy for a brighter future

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

Millenium Os. Luminaire LED. For Stairwells and Public Spaces. Designed and manufactured in the USA. High Abuse Motion-Activated Lighting Product

LED HIGH BAY LINEAR ECO SERIES

SDL4 LED Strip Diffused Lens

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

BAS SDL8' LED Strip Diffused Lens

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

TROFFER RETROFIT KIT (TRK)

P5500 LED Architectural Downlighting

SECTION INTERIOR LIGHTING

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

BACKUP BATTERY INSTALLATION INSTRUCTIONS

BAS SFP22 Edge-lit LED Panel

Lumination LED Luminaires

WARRANTY LED ECO PANEL.

Metalux SWLED LED. Type. Catalog # Project. Date. Comments. Prepared by

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

Project Name. Date. Cat. Number. Type

DHL-LP-LED Low Profile LED Linear High/Low Bay

Eligible Prescriptive Measures List:

LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

2018 Midstream Lighting Product Catalog

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

LED ECO PANEL.

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

Essentials Series 4.0

APPLICATIONS SPECIFICATION FEATURES ORDERING. Project: Notes: Catalog #: Large Outdoor Spaces. Swimming Pools. Shopping Malls. Large Indoor Spaces

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

Energy Star Directional Luminaire Test Report ELEC-TECH INTERNATIONAL CO LTD. LED Downlight

FPLHB - Fidelux Premier Linear Highbay

SERVICE BY QUALIFIED PERSONNEL ONLY

Pioneering Petroleum Canopy Lighting Since 1976

Product Specifications MaxLumen MRI LED Diffused Lighting

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

TRMUNV220ACXXXA UNIVERSAL VOLTAGE HIGHBAY RETROFIT KIT

LEDHB LINEAR HIGH-BAY LED LUMINAIRE PART NUMBER BUILDER 140L** 200L** 170L*** 230L*** 300L*** 400L*** 840* IN 48IN

LM Series LED Architectural Downlighting HIGH LUMEN OUTPUT RECESS / SURFACE MOUNT GREEN ENERGY EFFICIENT LIGHTING

Related Sections: TBD. Effective Date: January 1, 2016

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

SWITCHEX Dimmer + Driver

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

LHBXD LED Linear High Bay

56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network

LED LUMINAIRE SERIES LED Luminaire Series Improves Your Illumination Systems

LED RETROFIT CONVERSION KITS

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

Energy Solutions LED Accelerator Program PRODUCT QUALIFICATION REQUIREMENTS 2015

Architectural / led luminaires

Product Specifications MaxLumen MRI LED Diffused Lighting

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

SPECIFICATIONS Compliance & Regulatory Approvals DIMMER MODELS TRIM PLATES (SOLD SEPARATELY) SYSTEM DIAGRAM. Input. Output. Environmental Requirements

HIGH LUMINOUS EFFICIENCY

Step-Dimming and/or 0-10v Dimming Drivers Electro Galvanized Steel Welded Construction. Photocell Sensor - On/Off Stainless Steel Fasteners Standard

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

Transcription:

Emergency Lighting Product Guide LED The right source for the right light

Contents Emergency Lighting Is Code-Required...... 2 Life Safety Code...4 Emergency Backup Options...6 LED Terminology.......................... 7 Emergency LED Drivers.................... 8 Alternate Configurations...10 Field Installation... 12 Selecting Emergency LED Drivers... 14-15 Understanding NRTL Listings...16 TLED Lamps... 17 EM Driver Selection Chart...18-19 EM Drivers Product Summaries... 20-23 Emergency Lighting Inverters... 24-25 Dimming Inverters... 26 Inverter Products... 28-33 Inverter Products Summaries...34-35

Emergency LED Lighting LED technology is a new frontier. For most in the lighting industry there is a very real learning curve as we explore the intricacies, applications, limitations and potential of this amazing light source. Despite the curve, use of LED lighting for general lighting purposes is rapidly growing. Its popularity is not a mystery. LED technology is continually improving. LEDs offer long life and high efficiency, have low operating costs and are lead and mercury free. As with other types of lighting, LED lighting must meet the life safety code requirements for emergency illumination. LED fixtures serving as emergency units must, therefore, provide at least 90 minutes of emergency lighting. Philips Bodine emergency LED drivers and emergency lighting inverters allow these fixtures to meet or exceed code. 1

Emergency lighting is code required Emergency lighting is a vital part of every facility s life safety program. Local, state and national building codes, such as the NFPA Life Safety Code and National Electrical Code, require reliable and sufficient emergency illumination for commercial, industrial and institutional buildings in the United States. When normal power fails for any reason, emergency lighting provides critical illumination. It helps to guide building occupants along the path of egress to the nearest exit. Philips Bodine Emergency Lighting Provides Instant Backup Philips Bodine emergency lighting products provide instant backup lighting whenever normal power fails. Philips Bodine fluorescent emergency ballasts, emergency LED drivers and emergency lighting inverters deliver 90 minutes of battery-supplied power. Complements Original Designs Philips Bodine emergency lighting products complement original lighting designs. Because they can be installed inconspicuously inside, on top of, near or remote from the fixture depending on factors such as fixture, emergency lighting product and product model they do not detract from fixture or interior design. Philips Bodine emergency lighting is emergency lighting you ll never see until you need it. When normal power fails, Philips Bodine 90 minute battery power supply emergency lighting products sense the loss and immediately switch into emergency mode. 2 Philips Emergency Lighting

In field applications, a qualified electrician can typically install an emergency driver in less than 30 minutes. 30 minute installation Looks like normal lighting Philips Bodine emergency lighting products use the same light source for normal and emergency lighting. As a result, emergency lighting appears similar to lighting under normal conditions. May reduce the risk of tampering Installed Philips Bodine units are generally less visible than other forms of emergency lighting, such as wall packs. Their inconspicuous placement helps reduce their visibility to potential vandals. Application Philips Emergency Lighting provides Philips Bodine emergency lighting products for a wide variety of applications, including indoor, outdoor, damp, cold temperature and hazardous locations. Operation When normal power fails, Philips Bodine emergency lighting products sense the loss and immediately switch into emergency mode. This means the emergency lighting unit immediately begins supplying supplemental power to support emergency lighting operation for a minimum of 90 minutes. When normal power is restored, the emergency lighting unit returns to the charging mode. UL testing Philips Bodine emergency lighting products are tested by Underwriters Laboratories (UL) in accordance with standards set forth in UL 924, Emergency Lighting and Power Equipment, and/ or by other nationally recognized testing laboratories. 3

Life Safety Code AC power failures occur for a variety of reasons. Storms, tornadoes, hurricanes and other extreme weather conditions can affect AC power. Vehicular accidents, fires or equipment failure can also result in power outages. When this happens, liability concerns are inevitable. Serious accidents or mishaps could occur when occupants are left in total darkness during a power failure. In such instances, the first area of inquiry is often, Did this building meet code? Laws, Codes and Regulations Although state and local building codes vary, most are based upon: 1. National Electrical Code, NFPA 70, Article 700; 2. Life Safety Code, NFPA 101, Section 7.9; 3. Occupational Safety and Health Act (OSHA) regulations. These codes provide complete information about emergency lighting requirements. However, a basic starting point is provided in the LSC 7.9.2.1 (2012), which states: Emergency illumination shall be provided for a minimum of 1.5 hours in the event of failure of normal lighting. Emergency lighting facilities shall be arranged to provide initial illumination that is not less than an average of 1 ft-candle (10.8 lux) and, at any point, not less than 0.1 ft-candle (1.1 lux), measured along the path of egress at floor level. Illumination levels shall be permitted to decline to not less than an average of 0.6 ft-candle (6.5 lux) and, at any point, not less than 0.06 ft-candle (0.65 lux) at the end of 1.5 hours. A maximum-to-minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. It is important to remember that codes generally set minimum standards. Specifiers, building owners, facility management or municipalities may choose to go beyond minimums in their effort to keep people and property safe. Maintenance Codes mandate periodic monitoring of emergency lighting equipment once it is installed. Emergency operation must be tested at 30-day intervals for a minimum of 30 seconds, and, for battery-powered systems, a 90-minute discharge test must be conducted once a year. Additionally, the NFPA requires that records be kept as proof of maintenance. 15. Specifiers, building owners or facility management may choose to go beyond minimums in their effort to keep people and property safe. 4 Philips Emergency Lighting

Did this building meet code? Serious accidents or mishaps could occur when occupants are left in total darkness during a power failure. In such instances, the first area of inquiry is often: Did this building meet code? 5

Emergency solutions for LED lighting Choosing the appropriate emergency backup solution depends on the LED light source. Emergency drivers Emergency LED Drivers are the appropriate choice for applications utilizing an LED array powered by an external AC driver. Emergency LED drivers can be installed inside, on top of, or remotely from a fixture and operate one fixture during a power failure. Inverters Emergency inverters are the most flexible solutions for LED applications. They may be used in applications that utilize LED lighting driven by external drivers. They are also suited for screw-in (Edison base) lamps or linear (tubular) lamps with an integrated/internal AC driver. Inverters can be installed to operate more than one fixture during a power failure. As with other types of lighting, LED lighting must meet the life safety code requirements for emergency illumination to guide building occupants along the path of egress. 6 Philips Emergency Lighting

LED terminology LED: Light-emitting diode. A semiconductor device (diode) that emits visible light when electricity is applied. LED array: A configuration of one or more (usually many more) LEDs connected to the same power source. LED driver: A device that converts line voltage into the DC voltage and current necessary to drive the LED load. Emergency LED driver: A device that uses electronic circuitry to convert energy stored in a battery into the DC voltage and current necessary to drive the LED load within the parameters established by life safety codes. Integral-base LED lamp: A lamp in which the driver is built into the base. Because the lamp driver is built into the base, an emergency LED driver cannot be wired in between it and the lamp/led/led array. A unit with an integral base must, therefore, be driven in emergency mode by an inverter product. TLED (tubular LED): A tubular shaped LED lamp designed to replace the lamps in fluorescent fixtures. Various types of TLED lamps are available to use depending on the type of fixture and/or power source being used. Some TLEDs have integral drivers that operate without external drivers. LEDs in parallel: In parallel devices, all of the (+) terminals are connected and all of the (-) terminals are connected. Each connected component has the same voltage across it and draws as much current as its internal resistance allows. If all the components are exactly the same, the current through each will be equal and the total current draw from the power supply will be the individual current multiplied by the number of components or parallel legs connected. When LEDs are wired in parallel, each LED or group of LEDs will have the same voltage demand from the driver and draw an equal amount of current. LEDs in a series: The (+) terminal of one LED is connected to the (-) terminal of the next. When LEDs are wired in series, the voltage necessary to run them is the sum of the individual LED voltage drop and the current is the same in all LEDs. 7

Emergency LED drivers 90 minute illumination The Philips Bodine emergency LED driver line allows LED fixtures to serve as code-compliant emergency lighting sources. The expanding line includes drivers designed for a variety of applications: indoor, outdoor, damp, cold temperatures, steplights, downlights, security lighting, Class 2 installations and more. When normal AC power fails, the emergency LED drivers switch into emergency mode and support LED fixtures for 90 minutes. As with other types of lighting, LED lighting must meet life safety code requirements for emergency lighting when it is used in an emergency capacity. Therefore, LED fixtures serving as emergency lighting sources must provide 90 minutes of illumination in the event of a power failure. When normal AC power fails, the emergency LED drivers switch into emergency mode and support LED fixtures for 90 minutes. When AC power is restored, the drivers automatically return to the charging mode. For more EM driver information, please visit: philips.com/bodine 8 Philips Emergency Lighting

Alternate models and configurations are available for many Philips Bodine emergency LED drivers and are listed for field and/or factory installation. Check our website for more information, instructions and detailed product specifications. Philips Emergency Lighting www.philips.com/bodine up to 7W emergency mode BSL17C-C2 Provides up to 7 Watts (800 lumens*) in emergency mode Ideal for recessed downlights, suitable for indoor/damp Listed for field installation - ETL, UL 924 and CSA C22.2 No. 141 compliant Class 2 output - UL 1310 Certified, CSA 22.2 No 223-M91 compliant Controlled power for predictable discharge 15-50 VDC for wide range of LED loads Universal input (120 through 277 VAC, 50/60 Hz) RoHS compliant up to emergency mode BSL310M (family) Provides up to 10 Watts (1150 lumens*) in emergency mode Ideal for linear strip fixtures; suitable for indoor/damp Listed for field installation - ETL, UL 924 and CSA C22.2 No. 141 compliant Class 2 output - UL 1310 Certified, CSA 22.2 No 223-M91 compliant Universal input (120-277 VAC) 2-wire input reduces wiring errors Selectable output range: 10-29 VDC or 30-50 VDC RoHS compliant up to 14W emergency mode BSL10 Cold-Pak Provides up to 14 Watts (1600 lumens*) in initial emergency mode Ideal for recessed downlights; suitable for indoor/damp, covered exteriors Listed for field installation - ETL, UL 924 emergency lighting compliant Operates in extreme cold environments: -20 C to +55 C (-4 F to +131 F) Class 2 output - UL 1310 Certified 24-52 VDC for wide range of LED loads RoHS compliant up to 20W emergency mode BSL20 (family) Provides up to 20 Watts (2300 lumens*) in emergency mode Ideal for high-output, high bay fixtures; suitable for indoor/damp Listed for field installation - ETL, UL 924 and CSA C22.2 No. 141 compliant Output Class 2 compliant (BSL20LV only) Constant output power Universal input (120-277 VAC) Auto-sensing output within each range RoHS compliant 9

Alternate configurations for flexible solutions Multiple test switch, case and mounting options give customers the flexibility to choose the best configuration for their LED lighting application. Many Philips Bodine emergency LED driver models are available with or without flexible conduit, with single or dual flex, with leads out the bottom and studs for mounting on a junction box, and with a variety of test switch configurations. Some models are also offered with battery options. For example, the BSL718 emergency LED driver can use a single or dual battery, while the shape of the BSL722 battery can be chosen to fit the luminaire dimensions. See individual product spec sheets or contact the sales department for more information. Every mounting option is not available for all BSL models. Violet rown Violet rown 2W ITS 2W ITS Push To Test Charging Indicator Light Multiple Options Philips Emergency Lighting offers configuration flexibility in case, mounting and test switch selection. 10 Philips Emergency Lighting

Model Class Rating Output Voltage (VDC) Typical Output Current (ma)* Average Output Power* Dimensions Feature / Benefit BSL23C (conduit) BSL23 (non-conduit) BSL26C (conduit) BSL26 (non-conduit) LVLE 3-20 225-410 4.5 W 9.4 x 2.4 x 1.5 Multiple mounting configurations LVLE 3-30 120-265 5.1 W 9.4 x 2.4 x 1.5 Multiple mounting configurations BSL36LP Class 2 15-52 100-400 W controlled output 21.5 x 1.18 x 1.18 Low profile Universal input BSL36 Cold Class 2 15-52 100-400 W controlled output 9.4 x 2.6 x 1.5 Cold temps (-4 F to +131 F) BSL17C (conduit) BSL17 (non-conduit) non Class 2 45-130 100-200 7.0 W controlled output 12 x 2.4 x 1.5 Multiple mounting configurations BSL17C-C2 (conduit) BSL17-C2 (non-conduit) Class 2 15-50 100-270 7.0 W 12 x 2.4 x 1.5 Multiple mounting configurations BSL17C-C2ST Class 2 15-50 470 7.0 W 12.0 x 2.4 x 1.5 Self-testing Multiple mounting configurations BSL10 Cold-Pak Class 2 24-52 200-400 10.0 W controlled output 8.97 x 3.5 x 2.9 Cold temps (-4 F to +131 F) BSL310 (non-conduit) Class 2 10-50 200-400 10.0 W 14.5 x 2.25 x 1.18 Polycarbonate case Selectable voltage BSL310C (conduit) BSL310M (non-conduit) Class 2 10-50 200-400 10.0 W 15.34 x 2.25 x 1.16 Universal input Selectable voltage BSL310C-DF (conduit) Class 2 10-50 200-400 10.0 W 15.34 x 2.25 x 1.16 Universal input Dual flex conduit on one end BSL310HAZ Class 2 10-50 200-400 10.0 W 15.34 x 2.25 x 1.16 Suitable for hazardous locations BSL310LPST Class 2 15-52 200-400 10.0 W controlled output 22.5 x 1.18 x 1.18 For thin/low profile fixtures Universal input Self-testing BSL310SB Class 2 10-50 200-400 10.0 W 6.57 x 2.25 x 1.18 BSL718 Class 2 20-50 300-900 18.0 W 9.4 x 2.2 x 1.05 BSL20LV Class 2 20-50 400-1000 20.0 W 16.6 x 2.8 x 2.85 Universal input Separate battery Normal or extreme temps 18 watts output power High output Constant output power Cold temps (-4 F to +131 F) BSL20MV BSL20HV non Class 2 50-130 125-200 150-400 100-160 20.0 W 16.6 x 2.8 x 2.85 High output Constant output power Cold temps (-4 F to +131 F) BSL722 (non-conduit) Class 2 28-33 700 23.1 W BSL722 Cold (non-conduit Class 2 28-33 700 23.1 W 9.4 x 2.2 x 1.05 + battery 9.4 x 2.2 x 1.05 + battery Universal input Drives two LED arrays in parallel Universal input Cold temps (-4 F to +140 F) Drives two LED arrays in parallel 11

Emergency LED drivers for field installation The placement of Philips Bodine emergency LED drivers is similar to that of fluorescent emergency ballasts. Depending upon the emergency LED driver selected and fixture type, the emergency driver may be installed inside, on top of or remote from the fixture. Until recently, most emergency LED drivers were listed as UL Component Recognized as factory install only or UL Classified. A Classified listing requires both operating compatibility and verification of fixture with the Design Lights Consortium (DLC) database before the emergency driver can be field installed in the fixture. The restrictions associated with these listings make it more difficult for contractors or electricians to install an emergency LED driver in the field for new or retrofit applications. Philips Emergency Lighting continues to lead the industry by providing the solutions required by lighting professionals to take advantage of this innovative technology. Philips Emergency Lighting now offers Philips Bodine fully ETL Listed, field-installable emergency LED drivers. A wide variety of Philips Bodine emergency LED drivers are ETL Listed and are the first and currently only emergency LED drivers with this listing for factory or field installation. Fully ETL Listed, field-installable emergency LED drivers: Eliminates factory installed up-charges for factory installation. Eliminates the legwork involved in the field installation process for investigating the DLC compliance for UL Classified emergency LED drivers To use a UL Classified emergency LED driver, one must ensure that: 1. The luminaire that will receive the emergency LED driver is actually in the DLC database. If it is not listed in the database, you can t install the EM driver in the field. 2. The luminaire must be compatible with the emergency LED driver. Even though the luminaire is listed in the database, this does not mean it is compatible. Some UL Classified emergency drivers are only compatible with their own brand of luminaires. All other manufacturers EM drivers are suitable for factory installation only or carry a UL Classified status. We have emergency LED drivers that carry these designations too. 12 Philips Emergency Lighting

Convert existing LED luminaires into code-required emergency lighting. Philips Bodine emergency LED drivers do not affect normal fixture operation and may be used with a switched or unswitched LED fixture. Fully Listed field-installable emergency LED drivers Eliminate time-consuming measures associated with Classified status 13

Understanding NRTL listings Philips Bodine emergency LED drivers and emergency inverters bear one or more of the following marks to certify compliance with standards associated with emergency lighting products. Each mark represents the approval of the emergency LED lighting product to be utilized as set forth by each NRTL (nationally recognized testing laboratory) and complies with the UL 924 emergency lighting standard. Each listing represents a set of standards that may or may not restrict the installation process. Philips Bodine emergency lighting products are submitted to various nationally recognized testing laboratories to undergo the strict approbation processes to certify quality, safety and compliance with life safety emergency lighting products. Intertek Listed certifies that products are fully listed for field or factory installation with rated LED loads. The ETL Listing for emergency drivers simplifies the process for field installation by eliminating the time consuming measures required by a Classified listing. UL Listed certifies that products are fully listed for factory or field installation without verification. Philips Bodine emergency inverters are fully UL Listed for field installation. However, there are no emergency LED drivers in the market at this time that have been certified with this mark. UL Classified listing is for factory or field installation for products that comply with operating compatibility and verification of the fixture with Design Lights Consortium (DLC database). This verification process can make it difficult for contractors or electricians to qualify field installations. UL Component Recognized for factory installation certifies that the emergency LED driver complies with UL 924 standards but must be installed in the factory only. 14 Philips Emergency Lighting

Retrofit TLED solutions TLEDs or tubular LEDs are popular lamp replacements for fluorescent fixtures being utilized today. TLED replacement lamps reduce energy costs without the expense of replacing the entire fluorescent fixture. Select Bodine Emergency Ballasts are UL Listed for Emergency operation of specific LED Retrofit (T8) Tube Applications. While several factors about TLED lamps should be considered, there are three primary LED retrofit tube applications: I. Standard fluorescent ballast with AC power into TLED. Ballast driven TLED may work with some Fluorescent Emergency Ballasts The following Bodine fluorescent emergency ballasts which provide AC output are compatible and will operate these LED Retrofit (T8) Tube Applications: B50, PEL-12 (Contractor grade B50), B30, LP600 2. Standard AC LED Driver with DC power into TLED. LED Driven TLED may use LED Emergency Driver The following Bodine LED emergency drivers which provide DC output will operate these specific DC input LED TLED Retrofit (T8) Tube applications: BSL310 Product Family, BSL310LP. Alernate Bodine models tested as needed for compatibility 3. Line Voltage TLED Applications In this application, the ac ballast is removed from the luminaire. All Bodine sinusoidal or line voltage inverters provide an emergency solution for TLED lamps which are driven at line voltage 120v-277v applications. Line voltage driven TLED For additional information please see our LED Retrofit Tube Reference Chart located on our website. Philips/bodine.com 15

Several factors should be considered when selecting an emergency LED driver including the environment and application, the total array voltage and the output required to meet the code requirements for emergency lighting. Refer to the following pages to help select the appropriate emergency LED driver for your application. 16 Philips Emergency Lighting

Selecting emergency LED drivers Use these simple steps and the chart on the following pages to select the best solution for your emergency LED lighting application. Start with these easy steps to select the proper emergency LED driver for your fixture. Identify the fixture being utilized and record the specification data*: 1. Make and model 2. Load Voltage of LED array(s) Vf 3. LED Load rated power Watts 4. Output current of the AC LED Amps driver into LED Load as applied Load Voltage Identify the LED s load voltage (Vf) This is the total forward voltage (Vf or stacked voltage) of the luminaire s LED array(s). This information can be found on the product spec sheet, labeling, or on the LED array(s), or by calling the luminaire tech support/product mgr or the customer service department. Wattage (W) Verify maximum power of LED load The LED load s rated power must be greater than or equal to the output of the selected EM LED driver. + = Total Vf Locate your fixture s (LED array) total load voltage at the top of the chart - Approximate Load Voltage - and find the available EM LED drivers for this voltage in the selected column. The type of luminaire and application/location will help determine which EM driver to use. LED load (W) > to EM driver power output (W) Designated as Power (W) for each EM LED driver on the chart. Use the chart to ensure the LED load s rated power (W) is greater than or equal to the EM Driver power output (W). Current (from AC driver) Maximum current into EM driver The maximum current from the AC driver must be less than or equal to the current the EM driver can accept. Lumens Verify emergency lumen output Find the approximate emergency lumen output for each EM driver on the chart or calculate. AC Driver XA (xxxx ma) < EM Driver XXA (xxxx ma) Use the chart to find the Max. AC Driver Output to confirm the maximum acceptable current for each EM driver. Lumens = lm/w X (W) Emergency illumination (lumens) can be calculated by multiplying the efficacy of the LED load (measured in lm/w) by the output power of the emergency driver (W). 17

Approximate Load Voltage (LED Array Vf) Emergency LED Driver Class Rating Max. AC Driver Output (A) Specs 3 V 6 V 10 V 12 V 15 V 18 V 20 V 24 V 28 V 30 V BSL26C BSL26 LVLE 1.5A Power (W) ~ Lumens 0.8 100 1.6 190 2.3 270 2.9 340 3.5 410 4.0 460 4.4 510 4.7 550 4.9 560 4.8 560 BSL36LP Class 2 2.5A Power (W) ~ Lumens BSL17C-C2 BSL17-C2 Class 2 1.5A Power (W) ~ Lumens 7.2 840 7.2 840 7.3 840 7.3 840 7.3 840 7.3 840 BSL17C-C2ST Self-testing Class 2 1.5A Power (W) ~ Lumens 7.2 840 7.2 840 7.3 840 7.3 840 7.3 840 7.3 840 BSL310 Red poly case Class 2 3.0A Power (W) ~ Lumens 4.4 510 5.7 660 7.0 810 8.3 960 9.5 1,100 10.6 1,230 11.7 1,350 9.6 1,100 BSL310M (C or C-DF) Class 2 3.0A Power (W) ~ Lumens 4.4 510 5.7 660 7.0 810 8.3 960 9.5 1,100 10.6 1,230 11.7 1,350 9.6 1,100 BSL310LP BSL310LPST Class 2 3.0A Power (W) ~ Lumens 9.9 1,140 10.3 1,190 10.5 1,210 10.4 1,200 10.4 1,200 10.3 1,190 BSL310SB Small case, Separate battery Class 2 3.0A Power (W) ~ Lumens 4.4 510 5.7 660 7.0 810 8.3 960 9.5 1,100 10.6 1,230 11.7 1,350 9.6 1,100 BSL20LV Class 2 5.0A Power (W) ~ Lumens 21.3 2,450 21.4 2,470 21.5 2,480 21.5 2,480 BSL36 Cold-Pak -20ºC to 55ºC Class 2 2.5A Power (W) ~ Lumens BSL10 Cold-Pak -20ºC to 55ºC Class 2 1.25 Power (W) ~ Lumens 14.6 1, 14.6 1, 14.6 1, 14.6 1, BSL722 BSL722 Cold-Pak 2016 NA Power (W) ~ Lumens 20.2 2,320 22.2 2,550 BSL718 (Ext. Temps) -20ºC to 60ºC Class 2 2.0A Power (W) ~ Lumens 18.0 2,070 18.0 2,070 18.0 2,070 18.0 2,070 BSL310Haz Suitable - Class 1, Div. 2 fixtures Class 2 3.0A Power (W) ~ Lumens 4.4 510 5.7 660 7.0 810 8.3 960 9.5 1,100 10.6 1,230 11.7 1,350 9.6 1,100 Approximate Load Voltage (LED Array Vf) Emergency LED Driver Class Rating Max. AC Driver Output (A) Specs 45V 48V 50V 54V 60V 66V 72V 78V 84V BSL17 BSL17C non Class 2 1.5A Power (W) ~ Lumens 7.3 850 7.3 850 7.4 850 7.4 850 7.4 850 7.4 850 7.4 850 7.4 850 7.4 850 BSL20MV non Class 2 5.0A Power (W) ~ Lumens 21.1 2,430 21.2 2,440 21.2 2,450 21.3 2,460 21.4 2,460 21.4 2,470 21.4 2,460 Approximate Load Voltage (LED Array Vf) Emergency LED Driver Class Rating Max. AC Driver Output (A) Specs 125V 129V 132V 138V 144V 150V 156V 162V 168V BSL20HV non Class 2 5.0A Power (W) ~ Lumens 21.7 2,500 21.7 2,500 21.8 2,510 21.8 2,510 21.7 2,500 21.8 2,510 21.7 2,500 21.8 2,510 21.9 2,520 Lumens In Emergency Mode = Lumens per Watt of Fixture x Output Power of Chosen EM Driver** = (Lm/W) x (W) 18 Philips Emergency Lighting

Approximate Load Voltage (LED Array Vf) Listing* Typical Fixture Type Location/Application 33 V 36 V 39 V 42 V 45 V 48 V 50 V 52 V Recessed downlight, Surface, Pendant Indoor, Damp Recessed downlight, Slim/Low-profile Indoor, Damp 7.3 840 7.2 840 7.2 840 7.1 830 7.2 830 7.1 820 7.1 820 Pending Recessed downlight, Surface, Pendant Indoor, Damp 7.3 840 7.2 840 7.2 840 7.1 830 7.2 830 7.1 820 7.1 820 Pending Recessed downlight, Surface, Pendant Indoor, Damp 10.2 1,180 10.8 1,250 11.3 1,300 11.4 1,320 11.0 1,270 10.3 1,180 9.8 1,130 Linear strip, Recessed, Surface, Pendant Indoor, Damp 10.2 1,180 10.8 1,250 11.3 1,300 11.4 1,320 11.0 1,270 10.3 1,180 9.8 1,130 Linear strip, Recessed, Surface, Pendant Indoor, Damp 10.3 1,180 10.2 1,180 10.5 1,220 10.4 1,200 10.4 1,200 10.2 1,180 10.2 1,180 10.1 1,170 Pending Linear strip, Slim/Low-profile Recessed, Surface, Pendant Indoor, Damp 10.2 1,180 10.8 1,250 11.3 1,300 11.4 1,320 11.0 1,270 10.3 1,180 9.8 1,130 Linear strip, Slim/Low-profile Recessed, Surface, Pendant Indoor, Damp 21.6 2,490 21.5 2,480 21.5 2,480 21.4 2,470 21.4 2,470 21.4 2,470 21.3 2,450 High output / High bay, Linear, Surface Indoor, Damp Recessed downlight, Surface, Bollards Indoor, Damp, Covered exteriors, Extreme temperatures 14.6 1,680 14.5 1,670 14.5 1,670 14.3 1,650 14.7 1, 14.6 1,680 14.5 1,680 14.4 1,660 Recessed downlight, Surface, Bollards Indoor, Damp, Covered exteriors, Extreme temperatures 23.1 2,660 Recessed downlight, Surface, Bollards Indoor, Damp, Covered exteriors, Extreme temperatures 18.0 2,070 18.0 2,070 18.0 2,070 18.0 2,070 18.0 2,070 18.0 2,070 18.0 2,070 Recessed downlight, Surface, Bollards Indoor, Damp, Covered exteriors, Extreme temperatures 10.2 1,180 10.8 1,250 11.3 1,300 11.4 1,320 11.0 1,270 10.3 1,180 9.8 1,130 Hazardous location Indoor, Damp, Hazardous location Approximate Load Voltage (LED Array Vf) Listing* Typical Fixture Type Location/Application 90V 96V 102V 108V 114V 120V 126V 130V 7.4 850 7.4 850 7.4 850 7.4 850 7.4 850 7.4 850 7.3 850 7.3 850 Recessed downlight, Surface, Pendant Indoor, Damp 21.5 2,470 21.5 2,470 21.4 2,470 21.5 2,470 21.5 2,470 21.4 2,470 21.5 2,470 21.5 2,480 High output / High bay, Linear, Surface Indoor, Damp Approximate Load Voltage (LED Array Vf) Listing* Typical Fixture Type Location/Application 174V 180V 186V 192V 198V 200V 205V 210V 21.9 2,520 21.9 2,520 21.9 2,520 21.9 2,520 21.9 2,530 21.9 2,530 High output / High bay, Linear, Surface Indoor, Damp * Check individual product specification sheets for Listing details regarding US and Canada and other product details including specifications, dimensions and installation options such as conduit, stud-mount and test switches. ** Lumen calculations based on 115 lumens/watts UL Component Recognized for factory installation only UL Classified for field installation with DLC Classified LED loads ETL Listed for field or factory installation with rated LED loads 19

Emergency LED drivers product summary Some emergency driver models are available with added features including Self-Test for automatic code-compliance testing, Cold-Pak for extreme cold environments and Low-Profile cases for narrow or space limited fixtures as well as products for hazardous locations. Please refer to our web site for more details. BSL23C BSL26/26C BSL17/17C BSL17C2/17C-C2 Emergency LED Driver 4.5 Watts output power Emergency LED Driver Up to 5.1 Watts output power Emergency LED Driver Non Class 2 output 7 Watts output power Emergency LED Driver Class 2 output 7 Watts output power NRTL/C UL Recognized Factory Installation Only (Indoor and Damp) Illumination Time 90 Minutes Full Warranty 5 Years (NOT pro-rata) Dual Input Voltage 120/277 VAC, 60 Hz AC Input Current 280 ma AC Input Power Rating 2.0 W Output Voltage 3.0 to 20.0 VDC Output Current 410 ma (Maximum) Output Power 4.5 W (Maximum) Test Switch/Charging Indicator Light Illuminated Test Switch Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 250 ma Recharge Time 24 Hours Temperature Rating (Ambient) 0 C to +50 C (32 F to 122 F) Dimensions 9.4 x 2.4 x 1.5 (238 mm x 60 mm x 38 mm) Mounting Center 8.9 (226 mm) Weight BSL23-1.8 lbs. (0.82 kg) BSL23C Type 1-2.8 lbs. (1.3 kg) BSL23C Type 2-2.4 lbs. (1.1 kg) UL Recognized/CSA Certified Factory Installation Only (Indoor and Damp) Output LVLE Compliant Illumination Time 90 Minutes Full Warranty 5 Years (NOT pro-rata) Dual Input Voltage 120/277 VAC, 60 Hz AC Input Current 280 ma AC Input Power Rating 3.0 W Output Voltage 3.0 to 30 VDC (Maximum) Output Current 265 ma (Maximum) Output Power 5.1 W (Maximum), measured at nominal battery voltage Test Switch/Charging Indicator Light Illuminated Test Switch Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 250 ma Recharge Time 24 Hours Temperature Rating (Ambient) 0 C to +50 C (32 F to 122 F) Dimensions 9.4 x 2.4 x 1.5 (238 mm x 60 mm x 38 mm) Mounting Center 8.9 (226 mm) Weight BSL26-2.0 lbs. (0.91 kg) BSL26C Type 1-3.0 lbs. (1.4 kg) ETL Listed UL Recognized Factory Installation Only (Indoor and Damp) Illumination Time 90 Minutes Full Warranty 5 Years (NOT pro-rata) Universal Input Voltage 120-277 VAC, 50/60 Hz AC Input Current 45 ma AC Input Power Rating 3.0 W Output Voltage 30.0-130.0 VDC Output Current 175 ma (Maximum) Output Power 7.0 W (Maximum) Test Switch/Charging Indicator Light 2 W-ITS (2-Wire illuminated test switch)* Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 180 ma Recharge Time 24 Hours Temperature Rating Ambient : 0 C to +55 C (32 F to 131 F) Case: Tc (max): 65 C Dimensions 12.0 x 2.4 x 1.5 (304 mm x 60 mm x 38 mm) Mounting Center 11.5 (292 mm) Weight 4.3 lbs. (1.95 kg) UL Recognized Factory Installation Only (Indoor and Damp) Output Class 2 Compliant Illumination Time 90 Minutes Full Warranty 5 Years (NOT pro-rata) Universal Input Voltage 120-277 VAC, 50/60 Hz AC Input Current 45 ma AC Input Power Rating 3.0 W Output Voltage 15.0-50.0 VDC Output Current 470 ma (Maximum) Output Power 7.0 W (Maximum) Test Switch/Charging Indicator Light 2 W-ITS (2-Wire illuminated test switch)* Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 180 ma Recharge Time 24 Hours Temperature Rating Ambient : 0 C to +55 C (32 F to 131 F) Case: Tc (max): 65 C Dimensions 12.0 x 2.4 x 1.5 (304 mm x 60 mm x 38 mm) Mounting Center 11.5 (292 mm) Weight 4.3 lbs. (1.95 kg) *4 Wire - ITS is only offered on Type 1 Option 6 *4 Wire - ITS is only offered on Type 1 Option 6 20 Philips Emergency Lighting

BSL17C-C2ST BSL10 COLD-PAK BSL20LV BSL20MV/HV Emergency LED Driver - Self-Testing Class 2 output 7 Watts output power Emergency LED Driver, Class 2 Listed for field installation Extreme cold environments Emergency LED Driver High Output 20 Watts constant output power Emergency LED Driver High Output 20 Watts constant output power UL Recognized Factory Installation Only (Indoor and Damp) Output Class 2 Compliant Illumination Time 90 Minutes Full Warranty 5 Years (NOT pro-rata) Universal Input Voltage 120-277 VAC, 50/60 Hz AC Input Current 45 ma AC Input Power Rating 3.0 W Output Voltage 15.0-50.0 VDC Output Current 470 ma (Maximum) Output Power 7.0 W (Maximum) Test Switch/Charging Indicator Light 2 W-ITS (2-Wire illuminated test switch) Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 180 ma Recharge Time 24 Hours Temperature Rating (Ambient) Ambient : 0 C to +50 C (32 F to 122 F) Case: Tc (max): 65 C Dimensions 12.0 x 2.4 x 1.5 (304 mm x 60 mm x 38 mm) Mounting Center 11.5 (292 mm) Weight 4.3 lbs. (1.95 kg) ETL Listed For Field or Factory Installation (Indoor and Damp) UL Component Recognized For Factory Installation (Indoor and Damp) Illumination Time 90 Minutes Full Warranty 5 Years (NOT pro-rata) Dual Input Voltage 120 or 277 VAC, 60 Hz AC Input Current 200 ma maximum internal heater on 90 ma maximum internal heater off AC Input Power Rating 25 W maximum internal heater on 7 W maximum internal heater off Output Voltage 24-52 VDC Output Power 14.0 W initial output power NFPA 101 and NEC 700.12 compliant Test Switch/Charging Indicator Light Two-Wire Illuminated Test Switch (2W-ITS) Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 270 ma average Recharge Time 24 Hours Temperature Rating (Ambient) -20 C to +55 C (-4 F to +131 F) Dimensions 8.968 x 3.457 x 2.930 (227.8 mm x 87.8 mm x 74.4 mm) Mounting Center 8.514 (216.3 mm) Weight 3.6 lbs. (1.6Kg) - metal w/o conduit UL Recognized Factory Installation Only (Indoor and Damp) Output Class 2 Compliant Illumination Time 90 Minutes Full Warranty 5 Years (NOT pro-rata) Universal Input Voltage 120-277 VAC, 50/60 Hz AC Input Current 95 ma Maximum AC Input Power Rating 8.5 W Maximum Output Current and Voltage BSL20LV 1A-0.40A 20V-50V BSL20MV 0.40A-0.15A 50V-130V BSL20HV 0.16A-0.10A 125V-200V Output Power 20.0 W Test Switch/Charging Indicator Light Illuminated Test Switch 2W-ITS (2W-ITS can be mounted up to 50 feet from fixture) Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 275 ma Recharge Time 24 Hours Temperature Rating (Ambient) 0 C to +50 C (32 F to 122 F) Dimensions 16.6 x 2.8 x 2.85 (422 mm x 71 mm x 73 mm) 2 (610 mm) Flexible Conduit Mounting Center 15 (408mm) Weight 7.1 lbs. (3.22 kg) UL Recognized Factory Installation Only (Indoor and Damp) Illumination Time 90 Minutes Full Warranty 5 Years (NOT pro-rata) Universal Input Voltage 120-277 VAC, 50/60 Hz AC Input Current 95 ma Maximum AC Input Power Rating 8.5 W Maximum Output Current and Voltage BSL20LV 1A-0.55A 20V-36V Output Power 20.0 W Test Switch/Charging Indicator Light Illuminated Test Switch 2W-ITS (2W-ITS can be mounted up to 50 feet from fixture) Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 275 ma Recharge Time 24 Hours Temperature Rating (Ambient) 0 C to +50 C (32 F to 122 F) Dimensions 16.6 x 2.8 x 2.85 (422 mm x 71 mm x 73 mm) 2 (610 mm) Flexible Conduit Mounting Center 15 (408mm Weight 7.1 lbs. (3.22 kg) 21

Emergency LED drivers BSL36 Cold-Pak BSL36LP BSL310* BSL310LP/BSL310LPST* Emergency LED Driver, Class 2 Classified for Field Installation Extreme Cold Environments Low Profile Emergency LED Driver Class 2 output 6 Watts output power Emergency Driver for LED Strips Class 2 output 10 Watts output power Low Profile Emergency LED Driver Class 2 output 10 Watts output power UL Classified for US and Canada For Field or Factory Installation (Indoor and Damp) UL Recognized for US and Canada For Factory Installation (Indoor and Damp) UL Recognized Factory Installation Only (Indoor and Damp) Output Class 2 Compliant Illumination Time 90 Minutes UL Recognized Factory Installation Only* (Indoor and Damp) Illumination Time 90 Minutes UL Recognized Factory Installation Only (Indoor and Damp) Output Class 2 Compliant Illumination Time 90 Minutes Illumination Time 90 Minutes Initial Light Output 600 Lumens @ 25 C * Full Warranty 5 Years (NOT pro-rata) Initial Light Output 1000 Lumens @ 25 C * Full Warranty 5 Years (NOT pro-rata) Dual Input Voltage 120 or 277 VAC, 60 Hz AC Input Current 120 ma maximum with internal heater on 50 ma maximum when internal heater off AC Input Power Rating 13 W maximum with internal heater on 4 W maximum with internal heater off Output Voltage 15-52 VDC Output Power W minimum initial (regulated) NFPA 101 and NEC 700.12 compliant Test Switch/Charging Indicator Light Two-Wire Illuminated Test Switch (2W-ITS) Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 280 ma average Recharge Time 24 Hours Temperature Rating (Ambient) -20 C to +55 C (-4 F to +131 F) Dimensions 9.4 x 2.6 x 1.5 (238 mm x 67 mm x 38 mm) Mounting Center 8.9 (226 mm) Weight 2.1 lbs. (.95Kg) - metal w/o conduit Full Warranty 5 Years (NOT pro-rata) Universal Input Voltage 120-277 VAC, 50/60 Hz AC Input Current 40 ma maximum AC Input Power Rating 3.0 W maximum Output Voltage 15-52 VDC Output Power W initial (regulated) NFPA-101 and NEC 700.12 compliant Test Switch / Charging Indicator Light Two-Wire Illuminated Test Switch (2W-ITS) Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 150 ma average Recharge Time 24 Hours Temperature Rating (Ambient) 0 C to +55 C (32 F to 131 F) Dimensions 21.5 x 1.18 x 1.18 (546 mm x 30 mm x 30 mm) Mounting Center 21.1 (536 mm) Weight 2.0 lbs. (0.91 kg) - metal case without conduit Universal Input Voltage 120-277 VAC, 50/60 Hz AC Input Current 60 ma Maximum AC Input Power Rating minimum 200 ma, 35-50 VDC Output Power 10.0 W (Maximum) Test Switch/Charging Indicator Light Illuminated Test Switch Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 180 ma Recharge Time 24 Hours Temperature Rating (Ambient) 0 C to +55 C (32 F to 131 F) Dimensions 14.5 x 2.25 x 1.18 (369 mm x 58 mm x 30 mm) Mounting Center 14.0 (356 mm) Weight 2.25 lbs. (1.0 kg) Full Warranty 5 Years (NOT pro-rata) Universal Input Voltage 120-277 VAC, 50/60 Hz AC Input Current 65 ma maximum AC Input Power Rating 4 W maximum Output Voltage 15-52 VDC Output Power 10.0 W initial (regulated) NFPA-101 and NEC 700.12 compliant Test Switch / Charging Indicator Light Two-Wire Illuminated Test Switch (2W-ITS)** Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 180 ma average Recharge Time 24 Hours Temperature Rating (Ambient) Ambient : 0 C to +55 C (32 F to 131 F) Case: Tc (max): 65 C Dimensions 22.5 x 1.18 x 1.18 (572 mm x 30 mm x 30 mm) Mounting Center 22.1 (561 mm) Weight 2.5 lbs. (1.12 kg) - metal case without conduit *The BSL310LPST model is automatic code-compliance testing. 22 Philips Emergency Lighting

BSL310SB BSL310M** BSL718 BSL722 Emergency Driver for LED Strips Class 2 output Separate battery configuration Hazardous Locations Emergency Driver For LED Strips Class 2 output Emergency LED Driver Normal or extreme temps 18 Watts output power Emergency LED Driver 23.1 Watts output power UL Classified Factory Installation Only (Indoor and Damp) Output Class 2 Compliant Illumination Time 90 Minutes Full Warranty 5 Years (NOT pro-rata) Universal Input Voltage 120-277 VAC, 50/60 Hz AC Input Current 60 ma Maximum AC Input Power Ratin 4.0 W Maximum Output Current and Voltage Selectable Without Selector: minimum 200 ma, 30-50 VDC, With Selector: minimum 400 ma, 10-29 VDC Output Power 10.0 W (Maximum) Test Switch/Charging Indicator Light 1. 2W-ITS (2 wire Illuminated Test Switch) 2. IP67 rated 2W-ITS(can be used in wet locations). Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 180 ma Recharge Time 24 Hours Temperature Rating (Ambient) 0 C to +55 (32 F to 131 F) Dimensions (Enclosure Excluding Battery) 6.57 x 2.25 x 1.18 (167.mm x 57.mm x 30. mm) Mounting Center (152.4 mm) Weight 2.25 lbs. (1.0 kg) - polycarbonate ETL Listed For Field or Factory Installation (Indoor and Damp) UL Component Recognized For Factory Installation (Indoor and Damp) Illumination Time 90 Minutes Full Warranty 5 Years (NOT pro-rata) Universal Input Voltage 120-277 VAC, 50/60 Hz AC Input Current 60 ma Maximum AC Input Power Rating 4.0 W Maximum Output Current and Voltage Selectable (See Table 1) Without Selector: minimum 200 ma, 35-50 VDC, minimum 300 ma over optimized range (30-34 VDC) With Selector: minimum 400 ma, 10-29 VDC Output Power 10.0 W (Maximum) Test Switch/Charging Indicator Light Illuminated Test Switch Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 180 ma Recharge Time 24 Hours Temperature Rating (Ambient) 0 C to +55 C (32 F to 131 F) Dimensions 15.34 x 2.25 x 1.16 (369 mm x 58 mm x 30 mm) Mounting Center 15.0 (356 mm) Weight 3.45 lbs. (1.56kg) ** The BSL310C model comes with conduit. The BSL310HAZ model is UL Recognized for US and Canada UL Classified for US and Canada Field or Factory Installation (Indoor and Damp locations, Sealed and Gasketed fixtures) UL Recognized for US and Canada Factory Installation only (Indoor and Damp locations, Sealed and Gasketed fixtures) Illumination Time 90 Minutes Full Warranty 3 Years (NOT pro-rata) Universal Input Voltage 120 through 277 VAC, 50/60 Hz AC Input Current 65 ma (Maximum) AC Input Power Rating 5 W (Maximum) 1.0 W (Standby) Output Voltage 20.0 to 50.0 VDC Output Current 0.3-0.9 ADC Output Power 18.0 W Constant Allowable AC Driver Output Current (blue wire) 2.0A (Maximum) Test Switch Low Voltage, IP67 rated test switch (IPTS) with integral LED indicator Battery High-Temperature, Maintnance-Free Sealed lead acid batteries Recharge Time 24 Hours Charging Indicator Light LED (Optionally Provided) Temperature Rating (Ambient) -20 C to +60 C (-4 F to 140 F) Case: Tc (max) 80 C Dimensions 9.4 x 2.2 x 1.05 (238 mm x 55.9 mm x 26.7 mm) Mounting Center 8.9 (226 mm) Weight lbs. (2.72 kg) UL COMPONENT Recognized/CSA Certified Factory Installation Only (Indoor and Damp Locations) Illumination Time 90 Minutes Full Warranty 3 Years (NOT pro-rata) Universal Input Voltage 120 through 277 VAC, 50/60 Hz AC Input Current 80 ma AC Input Power Rating 7.5 W Output Voltage 28.0 to 33.0 VDC Output Current 700 ma Output Power 23.1 W (Maximum) Test Switch Low Voltage, IP67 rated ITS Battery High-Temperature, Maintenance-Free Nickel-Cadmium Batteries 7- to 10-Year Life Expectancy Battery Charging Current 160 ma Recharge Time 24 Hours Charging Indicator Light LED Temperature Rating (Ambient) 0 C to +60 C (32 F to 140 F) Dimensions 9.4 x 2.2 x 1.05 (238 mm x 55.9 mm x 26.7 mm) Mounting Center 8.9 (226 mm) Weight 4 lbs. (1.82 kg) 23

Inverters for emergency lighting applications When an emergency LED driver cannot be used, line voltage inverters may be the best solution. Philips Bodine emergency lighting inverters are sinusoidal (sine wave) units that support LED and fluorescent fixtures during loss of normal AC power. The inverters sense the loss and immediately begin supplying emergency power to the designated lighting load. Philips Bodine inverters support emergency lighting for 90 minutes, in accordance with codeestablished runtime requirements (NFPA 101 Life Safety Code ). A key feature of Philips Bodine emergency lighting inverters is sinusoidal output. Sinusoidal output is especially important for LED applications and is characterized by low harmonic distortion and by clean power similar to that produced by utilitysupplied electricity. 24 Philips Emergency Lighting

Philips Bodine emergency inverters are compatible with LED, fluorescent and incandescent lighting and are UL Listed for field installation (UL 924 compliant). Check our website for more information, instructions and detailed product specifications. Philips Emergency Lighting www.philips.com/bodine up to 25W emergency operation ELI-S-20 UL Listed for field installation - UL 924 compliant Provides up to 25W in emergency mode LED friendly sinusoidal output Supplies 90 minutes emergency operation at full brightness Ideal for but not limited to screw-base LED lamps Auto-select input voltage to reduce wiring errors Provides power to the input side of the connected load Fused output load connections Remote installation up to 25 feet up to 100W emergency operation ELI-S-100 UL Listed for field installation - UL 924 and CSA C22.2 No. 141 compliant Provides up to 100W maximum output power - 90 minutes LED friendly sinusoidal output Dimming compatible with 0-10V systems Ideal for multiple fixture operation Available in 120V or 277V models Fused output load connectors Remote installation up to 250 feet up to 250W emergency operation ELI-S-250 UL Listed for field installation - UL 924 compliant Auto dimming of connected lighting with industry standard 0-10Vdc interface Dimmable lighting loads, Input power 1,000W max during normal operation Provides up to 250W in emergency mode - 90 minutes LED friendly sinusoidal output Ideal for multiple fixture operation Removable/replaceable electronics module Remote installation up to 1,000 feet Philips Bodine emergency inverters are UL Listed and comply with UL 924 emergency lighting standards. 90 minute emergency operation 25

Unique flexibility with dimming capabilities Reduce costs associated with coverage requirements by utilizing Philip Bodine dimming compatible emergency inverters. Dimming is another important Philips Bodine inverter feature and is intended for LED applications operating in emergency mode. Dimming delivers cost savings, flexibility and control. Currently, the Philips Bodine ELI-S-100 and the ELI-S-250 support dimming functionality making it possible to expand your emergency lighting coverage while reducing costs associated with coverage requirements for emergency lighting. Emergency lighting inverters are an excellent choice for use with multiple fixtures and in cases where emergency LED drivers cannot be used, such as with integral-base lamps. They also offer the advantage of long-distance remote installation. Philips Bodine emergency lighting inverters are UL Listed for field installation. *See, for example, the NFPA 101 Life Safety Code. For more inverter information, please visit: philips.com/bodine Emergency Inverter 8W 8W 8W 8W 26 Philips Emergency Lighting

Inverter Model Dimming Compatible Sinusoidal Output Output Power Case Dimensions Product Features / Benefits Remote Mounting ELI-S-20 25 Watts 16.6 x 2.8 x 2.85 ELI-S-100 100 Watts 12.6 x 9.8 x 4.7 ELI-S-250 250 Watts 12.0 x 12.5 x 10.0 Auto-Select 120V/277V Fused output load connections Dimming output voltage Fused output load connections Multiple fixture operation Field selectable Auto output voltage selection Auto dim 0-10V connected load Multiple fixture operation Up to 250 feet Up to 250 feet Up to 1,000 feet ELI-S-400 400 Watts 18.0 x 8.0 x 15.0 High output power Multiple fixture operation Transfer time: 1ms Up to 1,000 feet 27

ELI-S-20 inverter with up to 25W emergency output power Benefits Works with LED and fluorescent fixtures up to 25W Supplies 90 minutes emergency illumination at full brightness Provides power to the input side of the connected load Ideal for but not limited to screw-base LED lamps Compatible with Philips 22W TLED linear LED lamps and most munufacturers lamps Suitable for indoor dry and damp locations Features fused output load connections The Philips Bodine 25W ELI-S-20 emergency lighting inverter transforms LED and fluorescent fixtures into codecompliant emergency lighting. It is the ideal emergency backup for the Edison-base (screw-base) LED lamps that are commonly replacing CFLs in retrofit applications. and is a superior choice for office, retail, hospitality and other similar spaces. ELI-S-20 allows fixtures to be on, off, switched or dimmed. It supports 100% of the AC rated output throughout it s 90 minute runtime so fixtures operate at full brightness during emergency operation. The device provides power to the input side of the fixture, including the ballast, and is designed for use with indoor applications. The ELI-S-20 features an LED-friendly sinusoidal (sine) wave form and is UL Listed (25W) and CSA Certified (20W) unit equipment designed for new and retrofit lighting projects. AC input rating: 9.5W; output voltage 120/277 VAC (auto select), 60Hz Dimensions: 16.6 x 2.8 x 2.8 Remote mounting distance: 250 feet max. 5-year limited warranty The ELI-S-20 inverter is a battery-powered backup device that provides emergency power to a connected lighting load up to 25W. 28 Philips Emergency Lighting

The ELI-S-20 is the ideal emergency backup for a variety of LED applications and a superior choice for office, retail, hospitality, and similar spaces. 29

ELI-S-100 inverter with sinusoidal and dimming control output Benefits Dimming compatible with 0-10V systems Works with LED and fluorescent fixtures Supplies 90 minutes emergency illumination May be connected to one or more fixtures LED friendly sinusoidal (sine) waveform output Compatible with Philips 22W TLED linear LED lamps and most manufacturers lamps Suitable for indoor dry and damp locations Features fused output load connections Two models available: 120V and 277V The ELI-S-100 dimming capability allows a high power fixture to operate at a dimmed (100W maximum) emergencymode level. This eliminates reliance on a high power inverter to run the fixture. Alternately, ELI-S-100 allows a string of multiple fixtures to be driven in emergency mode at a combined 100W maximum. For example, four 100W LED fixtures may be connected to one ELI-S-100 and dimmed for emergency operation to 20% of normal power, with each LED fixture supplying 20W of output power (20W x 4 = 80W).* The ELI-S-100 provides a dimming control output of 2-10 volts, and the emergencymode dimming voltage is field-settable in five steps to provide nominally 20%, 40%, 60%, 80% or 100%. The dimming feature requires a dimming AC driver. The ELI-S-100 provides emergency output power of 100W maximum and supports the lighting load for a minimum of 90 minutes. While the ELI-S-100 works with both fluorescent and LED lighting, it offers two important features for LED applications: dimming capabilities and sinusoidal output. Typical 2 x 4 LED fixtures with AC dimmable drivers *Note dimming drivers are less efficient at reduced power. This inefficiency must be accounted for in the design. Dimensions: 12.56 x 9.81 x 4.67 ) Remote mounting distance: 250 feet max. ELI-S-100 s sinusoidal output and dimming feature delivers cost-savings, flexibility and control in LED applications. 30 Philips Emergency Lighting

The ELI-S-100 allows a string of multiple fixtures to be driven in emergency mode at a combined 100W maximum. 31

ELI-S-250 inverter with auto-sensing dimming control output Benefits Works with LED and fluorescent fixtures Supplies 90 minutes emergency illumination at full brightness Features pure sinusoidal output Automatic dimming of connected lighting with industry standard 0-10Vdc interface. Dimmable lighting loads, input power 1,000W max during normal operation Automatic output voltage select Removable/replaceable electronics module Compatible with Philips 22W TLED lenear LED lamps Dimensions: 12.0 x 12.5 x 10.0 Remote mounting distance: 1,000 feet maximum The ELI-S-250 features an auto-sensing dimming control output with an industry standard 0-10 Volts. This automatic dimming capability allows a group of multiple luminaires to be driven in emergency mode at a combined 250W maximum input power.* The ELI-S-250 is programmed to sense and calculate the necessary output needed to illuminate the connected fixtures, without the use of pre-set dip switches. For example, 25 (input) dimmable LED fixtures may be connected to one ELI-S-250 and automatically dimmed in emergency operation to a combined total of 250W. This would allow approximately of power consumption for each luminaire. The 250W output power level is internally sensed and maintained throughout the emergency situation for 90 minutes minimum. The 0-10V room dimmer controls, where used, are passed through the ELI-S-250 during normal, nonemergency conditions so normal dimming operations are not affected. In the event of normal AC power failure, the ELI-S-250 provides emergency power to the connected lighting luminaires for a minimum of 90 minutes. A low batteryvoltage disconnect circuit protects the inverter batteries from deep-discharge damage during prolonged power outages. When power is restored the ELI-S-250 returns to normal battery-charging mode and the batteries are fully restored within 24 hours. * NOTE: AC input power is always more than the LED or fluorescent output power rating. Additionally, LED drivers and fluorescent ballasts operate at a lower input-to-output power ratio in a dimmed condition than they do when operated at full brightness level. In normal conditions the total power of the connected luminaires can be up to 1,000 Watts. 32 Philips Emergency Lighting

Dimming system schematic Total dimmable power up to 1,000W Normal only Luminaire ANY QUANTITY Normal only Luminaire TOTAL DIMMA LE POWER UP TO 1000W Norm/Emer Luminaire Norm/Emer Luminaire Normal only Luminaire Normal only Luminaire DIM OUT + DIM OUT - Norm/Emer Luminaire Norm/Emer Luminaire 120 or 277 VAC Wall Switch From 0-10V DIM OUT + Room Dimmer DIM OUT - SW HOT COM (Neutral) UNSW HOT FGND { ELI-S-250 SW-1 Inverter ON / OFF Out HOT Out COM 120 or 277 VAC Non-dimming system schematic Total power up to 250W Normal only Luminaire ANY QUANTITY Normal only Luminaire Norm/Emer Luminaire TOTAL POWER = 250W Norm/Emer Luminaire Normal only Luminaire Normal only Luminaire Norm/Emer Luminaire Norm/Emer Luminaire 120 or 277 VAC Wall Switch From 0-10V DIM OUT + Room Dimmer DIM OUT - SW HOT COM (Neutral) UNSW HOT FGND { ELI-S-250 SW-1 Inverter ON / OFF Out HOT Out COM 120 or 277 VAC 33

Sinusoidal Inverters Philips Bodine sinusoidal emergency lighting inverters support a variety of lighting loads. All are UL Listed for field installation. Please see product specification sheets for more information on each inverter. ELI-S-20 Sinusoidal (sine wave) Output 20 or 25 Watts Power Auto Select 120 or 277 VAC Code-Compliant 90-Minute Runtime ELI-S-100 Sinusoidal (sine wave) Output Dimming Output Feature 100 Watts Power Maximum Code-Compliant 90-Minute Runtime ELI-S-250 Sinusoidal (sine wave) 250 Watts Power Maximum Output Automatic Output Voltage Select Automatic Dimming (0 to 10V) of Connected Load UL Listed UL924 Emergency Lighting Compliant Field Installation Illumination Time 90 Minutes Maximum Load Power (including AC ballast/driver) 20W, 20 VA (0 C to 50 C) UL and CSA 25W, 25 VA (0 C to 45 C) UL only Full Warranty 5 years (NOT pro-rata) AC Input Voltage 120 or 277 VAC, 60 Hz AC Input Current 90 ma AC Input Power Rating 9.5 W Output Voltage 120/277 VAC (Auto Select), 60Hz Output Current 120 V, 165 or 210 ma 277 V, 72 or 90 ma Test Switch Single Pole (Momentary) Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery, 7- to 10-year life expectancy Battery Charging Current 250 ma Recharge Time 24 Hours Charging Indicator Light LED Temperature Rating (ambient) 32 F to 122 F (0 C to 50 C) for 20W 32 F to 113 F (0 C to 45 C) for 25W Dimensions 16.6 x 2.8 x 2.85 (422 mm x 71 mm x 71 mm) Weight 5 lbs. (2.3 kg) UL Listed UL924 Emergency Lighting Compliant Field Installation Illumination Time 90 Minutes Maximum Load Power (including AC ballast/driver) 100W, 100 VA ± 0.9 pf Full Warranty Unit - 5 years full coverage Battery - 3 years plus 7 years additional pro-rata ELI-S-100-120V ELI-S-100-277V AC Input Voltage AC Input Voltage 120 VAC, 60 Hz 277 VAC, 60 Hz AC Input Current AC Input Current 370 ma Max charging 160 ma Max charging Output Voltage Output Voltage 120 VAC, 60 Hz 277 VAC, 60 Hz ELI-S-100-120V / ELI-S-100-277V AC Input Power Rating 45W Max Charging Test Switch 2W-ITS Battery Maintenance-Free Sealed Lead Acid Battery Recharge Time 24 Hours Charging Indicator Light LED Temperature Rating (ambient) 32 F to 104 F (0 C to 40 C) Dimensions 12.562 x 9.812 x 4.675 (319 mm x 249 mm x 119 mm) Weight 25 lbs. (11.34 kg) with batteries installed Special Features Fused Output Load Connections Battery Quick Connect Dimming Output Feature UL Listed for US and Canada UL924 Emergency Lighting Compliant Field Installation (Indoor and Damp) Illumination Time 90 Minutes Total Connected Output Load Dimmable lighting loads, Input power 1000W Maximum. Non-Dimmable lighting loads, Input power 250W Maximum. Maximum Output Power 250W into load PF +/- 0.90 (280 VA) Full Warranty 5 Years (not including batteries) Battery - 3 years plus 7 years additional pro-rata AC Input Voltage (dual): 120 VAC, 60 Hz or 277 VAC, 60 Hz Battery: 2 ea. required 12V (nominal), 35Ah Maintenance-Free Sealed Lead Acid Battery Recharge Time 24 Hours Charging Indicator Light / Test Switch 2W ITS (Integrated LED / Test Switch) Charging Indicator Light / Test Switch 2W ITS (Integrated LED / Test Switch) Output Voltage, Automatically Selected 120 VAC +/- 10%, or 277 VAC +/- 10% Temperature Rating (ambient) 68 F to 86 F (20 C to 30 C) Dimensions 12.0 H x 12.5 W x 10.0 D (317mm x 305mm x 254mm) Weight Enclosure and Electronics only: 16 lbs. (7.26 kg) Batteries, 25 lbs. ea., Batteries total: 50 lbs. (22.6 kg) Special Features Auto-Sensing Emergency Light Output Remote Install Up to 1,000 Feet 34 Philips Emergency Lighting

ELI-S-400 Sinusoidal (sine wave) Output 400 VA Power Maximum Transfer time - 1 ms Code-Compliant 90-Minute Runtime UL Listed UL924 Emergency Lighting Compliant Field Installation Illumination Time 90 Minutes Maximum Load Power 400W, 400 VA ± 0.5 pf minimum Full Warranty Unit 3 years full coverage Battery 1 year full, 4 years pro-rata Input Input voltage (dual): 120 or 277VAC Maximum input current: 5.8 A (120V), 2.6 A (277V) Input frequency: 60 Hz Synchronizing slew rate: 1 Hz per second nominal Input surge protection: Meets UL 924 Output Output voltage (dual): 120 or 277VAC, 60Hz Output regulation: (static) ± 5% based on a 0-100% resistive load Output distortion: Less than 3% THD linear load Load Power Factor:.5 lag to.5 lead Output frequency: Normally, synchronized to utility, ± 2 Hz during emergency Overload: 150% for five seconds Time to transfer to inverter after a utility power failure: 1 ms. Battery Type Maintenance-Free Sealed Lead Calcium Recharge Time 72 Hours (meets UL924) Battery Protection Automatic low-battery voltage disconnect and reverse polarity protection Automatic restart upon utility return. Temperature Rating (ambient) 68 F to 86 F (20 C to 30 C) Relative humidity 95% non-condensing Dimensions 22.0 W x 8.0 D x 1 H (559 mm x 203 mm x 406) Weight 98 lbs (44.4 kg) 35

Check our web site for more detailed product specifications. www.philips.com/bodine 36 Philips Emergency Lighting

Disclaimer The information in this guide is accurate at the time of writing. This guide is provided as is without expressed or implied warranty of any kind. Neither Philips or its agents assume any liability for any inaccuracies in this guide or losses incurred by use or misuse of the information in this guide. Philips will not be liable for any indirect, special, incidental or consequential damages (including damages for loss of business, loss of profits or the like). whether based on breach of contract, tort (including negligence) product liability or otherwise, even if Philips or its representatives have been advised of the possibility of such damages.