Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Similar documents
Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

IMI Heimeier Kit Hydroca ble

thermostatic valve body with stepless precision presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Multilux 4-Eclipse-Set

Thermostatic valves with radiator connection systems

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Standard. thermostatic valve body without presetting

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Control valves for floor heating systems. Floor Heating Manifolds

Mikrotherm. Manual Radiator Valves With presetting

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Floor Control Set. Floor Heating Controller For constant control of the supply temperature

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Thermostatic valve bodies

Thermostatic valve bodies

Flush individual room control for floor heating systems

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Three-way reversing valve

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Regulux. Radiator lockshield with drain-off facility. To be precise.

thermostatic inserts for radiators with integrated valves

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

Thermostatic head B. Thermostatic heads Secured model designed for public buildings

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Thermostatic head K. Thermostatic heads with built-in sensor and remote sensor

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Halo. Thermostatic heads with built-in sensor

Thermostatic heads. Thermostatic Heads For all thermostatic valve bodies and radiators with integrated valves

Thermostatic heads. For all thermostatic valve bodies and radiators with integrated valves

HERZ Regulating valve 4002

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

HERZ Differential Pressure Control Valve 4002

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

Art-Line. Absolutely Brilliant Temperature control was never so good

TS RD 7761 RD, 7761 RD

Installation and operating instructions

Globo H. Ball valves Gunmetal ball valve

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Energy Saving Series RADICAL

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Radical CPD BIM.

manifold, for radiators

VITA ECO. Save money & energy. Highly efficient radiator saving up to 10.5% on fuel bills, at a cost effective price. 03 / 06 RANGE.

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

Automatic balancing valves ASV-PV (new generation) DN 32-50

Thermostatic heads. for all thermostatic valve bodies and radiators with integrated valves. To be precise.

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

RA2000 Commercial TRVs

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Say heating. Say Herz. HERZ-Supply Engineering

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Convertible radiator valve for one-pipe systems, centre distance 35 mm

EMO T. Thermal actuator for heating, ventilation, and air conditioning systems. To be precise.

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

Partner Valve/High Quality Ball Valve LENO MSV-S

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

Dynacon Eclipse. Floor Heating Manifolds Floor heating manifold with automatic flow control

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Valves, controls + systems Flow, pressure and temperature balancing

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

AVTI Multifunctional self - acting controller

SOLUTIONS GUIDE. For total efficiency

Meet Max. Unique AFC technology

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

Radiator Valve Program

Technical Product Guide

STRAIGHT AND ANGLED THERMOSTATIC VALVES

Measuring instruments for hydraulic balancing

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

RA 2000 Series RA 15/6T & TB Conversion Valve

caleffi hydronic valves page 1 of 12

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

RA15/6T & TB Conversion Valve

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

Problem-solvers The Radiator Solution Range

V2461, V2471 Verafix-VK PRE-SETTABLE H-BLOCK FOR COMPACT RADIATORS

Temperature control of individual floor-heated rooms or mixed floor-heating/radiator systems

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

TA-Compact-P. Giving you MORE by giving you LESS

The New Caroma TMV20

Transcription:

Calypso exact Thermostatic Radiator Valves With stepless precision presetting

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Calypso exact Calypso exact thermostatic valve bodies are used in two-pipe warm water pump heating systems with normal to high temperature spread. The integrated stepless precision presetting makes precise hydraulic balancing possible with the aim of providing all heat consumers with hot water according to their heat requirements. The valve has a large flow range and is characterized by an optimized noise performance and very low flow tolerances. Key features > > Optimised noise behaviour Through specially designed setting > > High flow range For various applications > > Double O-ring seal For durable and maintenance free operation Technical description Applications area: Heating systems. Function: Control Stepless presetting Shut-off Dimensions: DN -20 Pressure class: PN Temperature: Max. working temperature: 120 C, with protection cap or actuator 0 C, with press connection 1 C. Min. working temperature: 2 C. Materials: Valve body: Brass O-rings: EPDM rubber Valve disc: EPDM rubber Return spring: Stainless steel Valve insert: Brass, PPS (polyphenylsulphide) The complete thermostatic insert can be replaced using the IMI Heimeier fitting tool without draining the system. Spindle: Niro-steel spindle with double O-ring sealing. Surface treatment: Valve body and fittings are nickel-plated. Marking: THE, country code, flow direction arrow, DN and KEYMARK-Designation. II+ Designation. White protection cap. Standards: Calypso exact valves meet the following requirements: KEYMARK certified and tested to DIN EN 21. the highly expanded version and the standard version of the specification FW 07 drawn up by the Arbeitsgemeinschaft Fernwärme (AGFW) (Working Group for District Heating). 011 Pipe connection: The female-threaded version is designed for connection to threaded pipe, or in conjunction with compression fittings, to copper or precision steel pipe. Not suitable for compression fitting for multi layer pipes. The male threaded version, in conjunction with the appropriate compression fittings, permits connection to plastic pipe or multi layer pipe. Connection to thermostatic head and actuator: IMI Heimeier M0x1. 2

Construction 6 4 1 2 7 1. Long-life double O-ring sealing. 2. Strong return spring in combination with high locating force ensures that the valve does not slacken off over time.. Valve body made of brass 4. Precise regulating part for accurate stepless presetting.. IMI Heimeier M0x1. connection technology. 6. Valve insert replaceable using the fitting tool without draining the system. 7. EPDM O-ring Application The thermostatic valve body Calypso exact is applied in twopipe pumped hot-water heating system with normal to high temperature spread. The valve has a wide flow range as well as optimised noise behaviour and very tight flow tolerances. In extensive systems, even water distribution should be maintained not only during specified normal operation, but also after a drop in room temperature or a break in operations, in order to avoid under or over-supply to parts of the system. To achieve this, the valve characteristic is designed so that the radiator mass-flow does not exceed about 1. times the nominal flow even at Preset 8 and with a fully-open valve. Corresponding to the standards EnEV and DIN V 4701-, Calypso exact thermostatic valve bodies can be designed with a p-band of up to max. 1 K or max. K. Optimized flow restriction Lowest flow tolerances 1 2 4 6 7 8 Noise behaviour To ensure low-noise performance, the following conditions must be met: On the basis of experience, the differential pressure over the thermostatic valves should not exceed about 20 kpa = 200 mbar = 0.2 bar. If in designing the system, higher transient differentials might be experienced in the part-load flow range, differential pressure control equipment such as a STAP Differential Pressure Controller or Hydrolux bypass valves can be used (see diagram for noise characteristic curve). Mass-flow must be correctly adjusted. The system must be completely deaerated.

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Sample application 1. Calypso exact thermostatic valve body 2. Regutec lockshield. STAP differential pressure controller 4. STAD balancing valve. Boiler Notes To avoid damage and the formation of scale deposit in the hot water heating system, the composition of the heat transfer medium should be in accordance with the VDI guideline 20. For industrial and long-distance energy systems, see the applicable codes VdTÜV and 1466/AGFW FW. A heat transfer medium containing mineral oils, or any type of lubricant containing mineral oil can have extremely negative effects and usually lead to the disintegration of EPDM seals. When using nitrite-free frost and corrosion resistance solutions with an ethylene glycol base, pay close attention to the details outlined in the manufacturers documentation, particularly concerning concentration and specific additives. The thermostatic valve bodies can be used with all IMI Heimeier thermostatic heads and IMI Heimeier or IMI TA thermal or motorized actuators. The optimal tuning of the components guarantees maximum safety. When using actuators from other manufacturers, make sure that the pressure power is appropriate for thermostatic valve bodies with soft sealing valve discs. Operation Presetting The presetting can be selected steplessly between 1 and 8. There are 7 additional marks between the preset values, thus enabling exact setting. Setting 8 corresponds to the standard setting (factory setting). The technician can undertake or change the setting with the setting key or spanner (1 mm). This ensures unauthorised persons cannot tamper with the setting. Plug the setting key or universal key into the valve insert and turn until it engages in position. Turn the index of the desired setting value to the index figure of the valve insert. Withdraw the key. The setting on the valve insert is visible from the actuating direction (see fig.). Front-end visibility 460-00.142 *) Index 4

Technical data Diagram, valve body with thermostatic head P-band [xp] 1.0 K P-band [xp] 2.0 K kv 0,02/ kv 0,02/ xp 0, K 2, 4, 6, xp 0, K 2, 4, 6, 1,,, 7, 1,,, 7, 0 00 0 00 0 db(a) 2 db(a) 2 db(a) 0 00 0 00 20 200 20 200 1 2 4 67 8 0 1 2 4 6 7 8 0 0 0 2 0 20 2 0 20 1 1 0, 0, p [kpa] 0, 0,2 0,1 1 2 ª [kg/h] 20 0 0 0 200 00 2 p [mbar] 1 00 p [kpa] 0, 0,2 0,1 1 2 ª [kg/h] 20 0 0 0 200 00 2 Δp [mbar] 1 00 Valve body (DN /1/20) with thermostatic head P-band [xp] 1.0K P-band [xp] 2.0K Presetting 1 2 4 6 7 8 kv-value 0,049 0,082 0, 0,21 0,246 0,0 0, 0,4 kv-value 0,049 0,090 0, 0,26 0,0 0,470 0,90 0,670 Kvs 0,049 0,2 0,18 0,1 0,420 0,6 0,740 0,860 Flow tolerance ± [%] 20 18 16 14 12 Permitted differential pressure, during which the valve is kept closed Δp [bar] Th.- head EMO T-TM/NC EMOtec/NC EMO 1/ EMO EIB/LON EMO T/NO EMOtec/NO 1,0,, Kv/Kvs = m /h at a pressure drop of 1 bar. Sample calculation Target: Setting range Given: Heat flow Q = 8 W Temperature spread ΔT = 1 K (6/0 C) Pressure loss, thermostatic valve ΔpV = 1 mbar Solution: Mass flow m = Q / (c ΔT) = 8 / (1,16 1) = 7 kg/h Setting range from Diagram: With P-band max. 1.0 K: 4, With P-band max. 2.0 K: 4 Kv Cv = 0,86 Kv = Cv 0,86

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Presetting table Presetting values for various radiator performances, pressure drops, and system spread T kpa = 0 mbar = 1 mws Presetting value at max. 2 K P-band. Q = radiator performance ΔT = system spread Δp = Differential pressure Example: Q = 00 W, ΔT = 1 K, Δp = kpa Presetting value: 4 Tips: For an approximate determination of the preset for given radiator performance and system spread, an average differential pressure of kpa is recommended. For systems that are widely extended horizontally, a differential pressure drop is necessary: eg, 1 kpa for valves near the central unit, kpa for valves at a medium range, and kpa for valves on remote radiators. An exact determination can only be carried out by making a pipe network calculation using the diagram, or with a calculation program. 6

Articles H1 SW2 Angle l SW1 D l l4 d2 DN D d2 l l4 l H1 Kv Kvs EAN Article No p-band max. 2 K Rp/8 R/8 24 49 20 24 0,02-0,670 0,86 40240292014 41-01.000 1 Rp1/2 R1/2 26 2 2, 0,02-0,670 0,86 402402922918 41-02.000 20 Rp/4 R/4 0 6 26 21, 0,02-0,670 0,86 402402927814 41-0.000 H1 2 d1 SW2 l l4 d2 Angle with male thread G /4 DN d1 d2 l l4 H1 Kv Kvs EAN Article No p-band max. 2 K 1 G/4 R1/2 26 2, 0,02 0,670 0,86 40240294911 4-02.000 SW1 SW2 H2 D l1 l2 d2 Straight DN D d2 l1 l2 H2 Kv Kvs EAN Article No p-band max. 2 K Rp/8 R/8 0 76 22, 0,02-0,670 0,86 402402926817 42-01.000 1 Rp1/2 R1/2 8 22, 0,02-0,670 0,86 402402926916 42-02.000 20 Rp/4 R/4 6 97 22, 0,02-0,670 0,86 40240292791 42-0.000 H2 d1 SW2 d2 Straight with male thread G /4 8 DN d1 d2 H2 Kv Kvs EAN Article No p-band max. 2 K 1 G/4 R1/2 22, 0,02 0,670 0,86 4024029494 46-02.000 22,0 DN 2, DN 1 26,0 DN 20 H1 D SW2 SW1 l l4 d2 Axial DN D d2 l l4 H1 Kv Kvs EAN Article No p-band max. 2 K Rp/8 R/8 24, 0 4, 0,02-0,670 0,86 40240292717 40-01.000 1 Rp1/2 R1/2 26 4, 0,02-0,670 0,86 402402927616 40-02.000 20 Rp/4 R/4 0 6 4, 0,02-0,670 0,86 40240292771 40-0.000 24, SW2 d2 Axial with male thread G /4 H1 d1 l l4 DN d1 d2 l l4 H1 Kv p-band max. 2 K Kvs EAN Article No 1 G/4 R1/2 26 4, 0,02 0,670 0,86 40240294919 47-02.000 *) SW1: DN = 22 mm, DN 1 = 27 mm, DN 20 = 2 mm SW2: DN = 27 mm, DN 1 = 0 mm, DN 20 = 7 mm Values H1 and H2 are at the bearing surface thermostatic head or actuator. Kvs = m /h at a pressure drop of 1 bar and fully open valve. Kv [xp] max. 2 K = m /h at a pressure drop of 1 bar with thermostatic head. 7

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Accessories Setting key For Calypso exact. EAN Article No 4024022216 460-00.142 Fitting tool complete with case, box spanner and replacement seals, for replacing thermostatic inserts without draining off the heating system (for DN to DN 20). EAN Article No Fitting tool 402402298914 9721-00.000 Replacement seals 4024022990 9721-00.14 Compression fitting for copper or precision steel pipe according to DIN EN 7/0-1/2. Female thread connection Rp /8 Rp /4. Metal-to-metal joint. Brass nickel-plated. Support sleeves should be used for a pipe wall thickness of 0.8 1 mm. Follow the specifications of the pipe manufacturer. Ø Pipe DN EAN Article No 12 (/8 ) 402402174614 2201-12.1 14 1 (1/2 ) 40240217471 2201-14.1 1 1 (1/2 ) 40240217017 2201-1.1 16 1 (1/2 ) 40240217116 2201-16.1 18 20 (/4 ) 4024021721 2201-18.1 Support sleeve for copper or precision steel pipe with a 1 mm wall thickness. Brass. Ø Pipe L EAN Article No 12 2,0 402402127016 0-12.170 1 26,0 402402127917 0-1.170 16 26, 402402128419 0-16.170 18 26,8 40240212881 0-18.170 Double connection fitting For clamping plastic, copper, precision steel or multi-layer pipes. Brass, nickel-plated. L EAN Article No G/4 x R1/2 26 4024020841 121-12.08 Compression fitting for copper or precision steel pipe according to DIN EN 7/0-1/2. Connection male thread G /4 according to DIN EN 161 (Eurocone). Metal-to-metal joint. Brass nickel-plated. With a pipe wall thickness of 0.8-1 mm insert supporting sleeves. Heed pipe manufacturer s technical advice. Compression fitting for copper or precision steel pipe according to DIN EN 7/0-1/2. Connection male thread G /4 according to DIN EN 161 (Eurocone). Soft sealed, max. 9 C. Nickel-plated brass. Ø Pipe EAN Article No 12 402402214211 81-12.1 14 402402214 81-14.1 1 402402214617 81-1.1 16 402402214914 81-16.1 18 40240221218 81-18.1 Ø Pipe EAN Article No 1 402402181 11-1.1 16 402402190 11-16.1 18 4024021606 11-18.1 8

Compression fitting for plastic pipe according to DIN 4726, ISO 08. PE-X: DIN 16892/1689, EN ISO 187; PB: DIN 16968/16969. Connection male thread G /4 according to DIN EN 161 (Eurocone). Nickel plated brass. Ø Pipe EAN Article No 12x1,1 40240216018 11-12.1 14x2 40240214618 111-14.1 16x1, 40240216117 11-16.1 16x2 40240214816 111-16.1 17x2 4024021491 111-17.1 18x2 40240211 111-18.1 20x2 402402118 111-20.1 Compression fitting for Alu/PEX multi-layer pipe according to DIN 1686. Connection male thread G /4 according to DIN EN 161 (Eurocone). Nickel-plated brass. Ø Pipe EAN Article No 14x2 4024021721 11-14.1 16x2 4024021712 11-16.1 18x2 40240217411 11-18.1 Ø M0x1, 87, Thermostatic head K with built-in sensor Graduation cap, white RAL 9016. With two economy clips. For further thermostatic heads and information see Thermostatic head K brochure. Setting range 6 C - 28 C Number on dial 1-6 C - 28 C Setting scale with temperature values EAN Article No 40240221920 6000-09.00 40240261612 6000-00.600 81 22 Ø M0x1, 87, Thermostatic head K with remote sensor Capillary tube length 2 m Graduation cap, white RAL 9016. With two economy clips. For further thermostatic heads and information see Thermostatic head K brochure Setting range 6 C - 28 C Number on dial 1-6 C - 28 C Setting scale with temperature values EAN Article No 4024022601 6002-00.00 402402618 6002-00.600 Ø 48 M0x1, 80 Thermostatic head DX With built-in sensor. Setting scale with numbers 1. Graduation cap, white RAL 9016. For further thermostatic heads and information see Thermostatic head DX brochure. Setting range EAN Article No 6 C - 28 C 402402494026 6700-00.00 Ø48 80 Thermostatic head D-U With built-in sensor. Setting scale with numbers 1. Graduation cap, white RAL 9016. For further thermostatic heads and information see Thermostatic head D-U brochure. Setting range EAN Article No 6 C - 28 C 4024024672 682-00.00 M0x1, 9

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact Ø 49 M0x1, 8 Thermostatic head B For public buildings. Infinitely variable temperature setting using a special key without having to remove the protection cap. Protection cap can be turned endlessly. Protected against theft. Flexural strength of the thermostatic head min. 00 N. White protection cap RAL 9016. For further thermostatic heads and information see Thermostatic head B brochure. Setting range EAN Article No 8 C - 26 C 40240218812 200-00.00 9 M0x1, 80 Ø 9, Thermostatic head F Remote dial with built-in sensor. Capillary tube length 2 m. Setting scale with numbers 1. Graduation cap, white RAL 9016. For further thermostatic heads and information see Thermostatic head F brochure. Setting range EAN Article No 0 C - 27 C 4024021917 2802-00.00 Other accessories, see catalogue leaflet Accessories and spare parts for thermostatic radiator valves.

11

IMI HEIMEIER / Thermostatic Heads & Radiator Valves / Calypso exact The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.imi-hydronic.com. Calypso exact 08.2017