Photo Beam 5000/3000 Series Heater. en Installation Guide

Similar documents
Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Battery charger modules

Annunciators, 8 LED. D7030X, D7030X-S2, and D7030X-S8. Installation Manual

Commercial Series TriTech Motion Detector. Reference Guide

Duct smoke housing, 2-wire D340/D340P

Duct smoke housings, 4-wire D341/D341P and D342/D342P

DS7465i. Installation Instructions. Input/Output Module

F220-B6PS/M. Installation Guide. Addressable Detector Bases

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

Commercial Series TriTech+ Motion Detector with Anti-mask

Fire Alarm Control Panels FPD-7024

Quick Selection Guide Intrusion Detectors

Multiplex Eight Input Remote Modules

MO144. Operators Guide. Universal Timer Module

Remote NAC Power Supply D7038

FMR Installation Instructions. Addressable Fire System Controller

D250A/D253/D261AW/D280A/D290 Series

Addressable NAC Output Module D327A

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

Notification Appliance Circuit Module

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

Smoke Alarm FERION 1000 O

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

RF280THS. Installation Instructions Wireless (RF) Photoelectric Smoke Detectors

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

TrueAlarm Smoke Detectors

RADION smoke RFSM-A. en Installation Guide

D343. Installation Instructions. Air Duct Smoke Housing

Fireray 2000 Linear Smoke Detector

D7052. Installation Instructions Multiplex Dual Input Module

DS160/161 Request To Exit PIR sensors Installation Instructions

Bosch EVAX System - High-rise Applications

Analogue Detectors. Series 200 plus

D7053. Installation Instructions Multiplex Input/Output Module

D8125MUX. Operation and Installation Guide. Multiplex Bus Interface

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

EVID-S Surface Mount 12 Subwoofers

TrueAlert Addressable Notification

Conventional Detectors

D7044. Installation Instructions Multiplex Single Input Module

Twin Photobeam Detectors Manual

D7024 Fire Alarm Control Panel

EVID FM-Series Loudspeaker User Manual

Analog fire panels FPA-1000 Family

IDP-Zone-6 Six Zone Interface Module

D285DH. Installation Instructions Photoelectric Duct Smoke Detector

DS7400Xi Addressable Control/ Communicator

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

AL600ULX Series. Power Supply/Charger. Installation Guide

D296/D297. Application Guide. Projected Beam Smoke Detectors

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

Intrusion Outdoor Protection Perimeter

TrueAlarm Analog Sensing

DS160/DS161 Request To Exit PIR sensors Installation Instructions

30.45 Electric Release PDRP-2001

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Quadruple-beam photoelectric detector

Model 17A00 Expansion Enclosure

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

ELP21LU3-LF-HLOL THREE CHANNEL

General Routing Interface

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

1 PRODUCT COMPONENTS This section describes the contents of the product package and the names and functions of

TrueAlarm Analog Sensing

APC BC300 Series 40kW 208/450/480V User Guide

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Substation Monitoring System

D1255RB/D1256RB/D1257RB

- Four (4) Fused Outputs - Four (4) PTC Outputs. - Eight (8) Fused Outputs - Eight (8) PTC Outputs

TrueAlarm Analog Sensing

Intelligent Addressable Fire Alarm System

OPERATING MANUAL Enertronic Control System 2

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

DS860 Surface or Corner Mount TriTech PIR/Microwave Detector

Quick Selection Guide Analog Addressable Fire Systems

Easy Series Control Panel ICP-EZM2

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

Multiple Input and Output Modules

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

ID50series. intelligent fire alarm panels

Public Safety DAS Annunciator Panel

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

Professional Series TriTech+ Motion Detectors with Anti mask

RPSMLR2 RPSMLR2BB. Panic Device Power Controller Installation Guide LISTED. Rev

TECHNICAL DATA OBSOLETE

Active Infrared Multi Beam Sensors

THINLINE TL2 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

Modular Fire Panel 5000 Series Just as flexible as your plans

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

TrueAlert Notification Appliances

Intrusion. Outdoor protection perimeter

CODESEC FIRE ALARM SYSTEMS. security technologies

MANUAL RESET ALARM RELEASE

Flexibility right from the start. PAVIRO Public Address and Voice Evacuation System with Professional Sound Quality. boschsecurity.

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

Transcription:

Photo Beam 5000/3000 Series Heater en Installation Guide

Photo Beam 5000/3000 Series Heater Table of Contents en 3 Table of contents 1 Introduction 4 1.1 About documentation 4 2 General description 5 3 Wiring 6 4 Installation 8 4.1 Mounting inside the ISC-FPB1-WxxDS type dual beam detectors 8 4.2 Mounting inside the ISC-FPB1-WxxxQS/QF type quad beam detectors 8 5 Characteristics 10 5.1 12 VDC current draw and temperature characteristics 10 5.2 24 VDC current draw and temperature characteristics 11 Bosch Security Systems, Inc. Installation Guide 2015.07 01 F.01U.315.476

4 en Introduction Photo Beam 5000/3000 Series Heater 1 Introduction This document contains information that a trained installer needs to install the BH12T heater onto the Photoelectric Beam Detector. 1.1 About documentation Copyright This document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. 2015.07 01 F.01U.315.476 Installation Guide Bosch Security Systems, Inc.

Photo Beam 5000/3000 Series Heater General description en 5 2 General description The BH12T heater is a heating device for ISC-FPB1-xxx family Photoelectric Beam Detectors. It helps to prevent frost build-up on beam optical modules and covers to ensure stable performance in harsh environmental conditions. The ceramic heater element automatically maintains constant temperature. Notice! Review the warnings and safety precaution notices in this document to prevent potential injury or product damage. Parts list The BH12T heaters are shipped from the factory with the following parts: Heaters (2) Heater mounting screws (4) Installation instructions Figure 2.1: Heater components Bosch Security Systems, Inc. Installation Guide 2015.07 01 F.01U.315.476

6 en Wiring Photo Beam 5000/3000 Series Heater 3 Wiring This section includes wiring procedures and supported wiring lengths. Supported wiring lengths are 0.65 mm to 1.2 mm diameter (22 to 16 AWG). The following table lists parameters that are calculated based on most common wire types and specifications. Notice! Distances indicated in the table below are maximum single unit specific values. For example, if you are using a wire diameter of 0.65 mm at 12 VDC, your maximum wiring distance allowed is 10 meters. Divide the given distance by the number of detector sets when more than one set of heaters is connected to the power supply. Maximum wiring distances for 1 heater Metric parameters Wire diameter 12 VDC 24 VDC 28 VDC 0.65 mm 10 m 98 m 127 m 0.90 mm 21 m 192 m 249 m 1.29 mm 39 m 351 m 455 m Imperial Unit parameters Wire gauge 12 VDC 24 VDC 28 VDS 22 AWG 33 ft 321 ft 417 ft 19 AWG 69 ft 630 ft 817 ft 16 AWG 128 ft 1151 ft 1492 ft Table 3.1: Wiring information Use separate power supplies for the detector and the heater to avoid the unstable operation caused by dynamic voltage drop during power-up. Use a battery backup type power supply preferably with an adjustable supply voltage level. Use a power supervision relay to indicate AC MAINS fail and/or low battery condition to the security control panel. Perform the following steps as each installation is different and various cable types have slightly different electrical parameters: Measure the impedance of the type of cable you plan to use. It is easiest to use a 100 m or 100 ft wire section for your measurement. Short one end of the wire pair of the cable and measure the total resistance on the other end. Use the measure value as basis to calculate each wire section. Notice! If the wire is damaged or strained during installation, the impedance of the wire might be higher than calculated or measure when operating current is drawn by the heaters. 2015.07 01 F.01U.315.476 Installation Guide Bosch Security Systems, Inc.

Photo Beam 5000/3000 Series Heater Wiring en 7 When possible, use a cable with at least two extra unused wires in case the resistance value must be reduced. In such case, connect each of the two extra wires in parallel with each of the power supply lines splitting the current on the wires and significantly reduce the resistance and corresponding voltage drop level. Apply Kirchhoff s Current Law (KCL) and Voltage Law (KVL) to estimate the voltage drops on each wire section, in case multiple heaters are daisy chained on one cable pair. Notice! Use caution when the calculated values result in parameters close to minimum voltage levels and/or maximum length and current draw parameters. Over-calculate the results by 15 to 20% when determining the appropriate cable size. This is to eliminate the risk of insufficient power levels due to differences between calculated, simulated and real installation electrical parameters. Calculate the maximum overall inrush current of all heaters on the wire and select a power supply which allows the necessary short term high current levels without regulating the voltage level or limiting the output current. Measure the maximum voltage level of the power supply unit while the AC MAINS power is connected and the batteries are charging. Measure the voltage level of the power supply unit while the AC MAINS power is disconnected and the batteries supply the voltage to the power supply. Measure the voltage level of the power supply unit while the AC MAINS power is disconnected and the batteries supply the voltage to the power supply. Apply a resistive load that draws approximately the same or similar current as the heaters would on the wire. Let the power supply run for 10 minutes on batteries only. Measure the voltage level of the power supply unit while the AC MAINS power is disconnected and the batteries supply the voltage to the power supply. Some intelligent power supplies up-convert the battery voltage to maintain the required voltage level while the voltage of the individual batteries is gradually decreasing. Such power supplies might provide shorter backup power time to maintain sufficient output power levels. Compare the voltage levels measured: When the AC MAINS power is on When the AC MAINS power is momentarily off When the AC MAINS power is off for 10 minutes These measurements provide a good indication on how the voltage drop changes on the heater power line in case of a power outage. Make sure the cable size calculation allows the heaters to have sufficient power levels while the power supply is running on backup batteries for a longer period of time. These parameters also provide sufficient information to calculate the necessary backup battery capacity. Bosch Security Systems, Inc. Installation Guide 2015.07 01 F.01U.315.476

8 en Installation Photo Beam 5000/3000 Series Heater 4 Installation Use the terminal mounting screws to attach the terminal to the beam detector. It is recommended to mount the heaters onto the detector on a flat, horizontal surface before you bring the device to the final mounting location. Observe the orientation of the device on the figures below and make sure the metal plate is facing towards the optical module. 4.1 Mounting inside the ISC-FPB1-WxxDS type dual beam detectors Refer to the following for installation information. Compatible devices ISC-FPB1-W30DS ISC-FPB1-W60DS ISC-FPB1-W90DS Refer to the following figure for securing the wires under the plastic tabs. Figure 4.1: Wire insertion under plastic tab 4.2 Mounting inside the ISC-FPB1-WxxxQS/QF type quad beam detectors The heater is mounted directly on the optical unit housing of the quad beam detector. Refer to the installation instructions of the compatible photobeams for installation information. Notice! If the heater is installed after the beam detector is mounted and operational (retrofit applications), perform an optical alignment procedure to ensure proper functionality. Compatible devices ISC-FPB1-W60QS ISC-FPB1-W120QS ISC-FPB1-W200QS 2015.07 01 F.01U.315.476 Installation Guide Bosch Security Systems, Inc.

Photo Beam 5000/3000 Series Heater Installation en 9 ISC-FPB1-W60QF ISC-FPB1-W120QF ISC-FPB1-W200QF Refer to the following figure for securing the wires under the plastic tabs. Figure 4.2: Left: upper optical module; right: lower optical module Bosch Security Systems, Inc. Installation Guide 2015.07 01 F.01U.315.476

10 en Characteristics Photo Beam 5000/3000 Series Heater 5 5.1 Characteristics Refer to the following information for heater specification information. 12 VDC current draw and temperature characteristics Supply voltage Outside temperature Inrush current Operating current 12 VDC 25 (77 ) 182 ma 40 ma 0 (32 ) 263 ma 90 ma -25 (-13 ) 280 ma 110 ma Figure 5.1: Left: 12VDC at 25 (77 ) with Current Draw over time (in minutes); right: Heater Temperature over time (in minutes) Figure 5.2: Left: 12VDC at 0 (32 ) with Current Draw over time (in minutes) ; right: Heater Temperature over time (in minutes) Figure 5.3: Left: 12VDC at -25 (-13 ) with Current Draw over time (in minutes) ; right: Heater Temperature over time (in minutes) 2015.07 01 F.01U.315.476 Installation Guide Bosch Security Systems, Inc.

Photo Beam 5000/3000 Series Heater Characteristics en 11 5.2 24 VDC current draw and temperature characteristics Supply voltage Outside temperature Inrush current Operating current 24 VDC 25 (77 ) 407 ma 30 ma 0 (32 ) 600 ma 60 ma -25 (-13 ) 600 ma 90 ma Figure 5.4: Left: 24 VDC at 25 (77 ) with Current Draw over time (in minutes); right: Heater Temperature over time (in minutes) Figure 5.5: Left: 24 VDC at 0 (32 ) with Current Draw over time (in minutes); right: Heater Temperature over time (in minutes) Figure 5.6: Left: 24 VDC at -25 (-13 ) with Current Draw over time (in minutes); right: Heater Temperature over time (in minutes) Bosch Security Systems, Inc. Installation Guide 2015.07 01 F.01U.315.476

Bosch Security Systems, Inc. 130 Perinton Parkway Fairport, NY 14450 USA www.boschsecurity.com Bosch Security Systems, Inc., 2015 Bosch Sicherheitssysteme GmbH Robert-Bosch-Ring 5 85630 Grasbrunn Germany