McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

Similar documents
AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

McQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978

Air Cooled Scroll Compressor Condensing Unit

Climate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

MDT2 Service Parts. Table of Contents Cabinet Page 2. Condensing System Page 3. Water and Dispensing Page 4. Water and Dispensing Part Numbers Page 5

Daikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

REPLACEMENT PARTS MANUAL

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS

Parts List. Modular Crescent Cuber. Models KM-340MAJ, MWJ. hoshizakiamerica.com

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

NM952 SERVICE PARTS TABLE OF CONTENTS. Cabinet Air Cooled Refrigeration Water Cooled Refrigeration Water System Gearmotor...

McQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018

Parts List. Modular Crescent Cuber. Models KMD-460MAH, MWH KMD-530MAH, MWH, MRH. hoshizakiamerica.com

SCE170 SERVICE PARTS

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018

AFE400 SERVICE PARTS

AAF. Fan Coil XR 1-9. Last Manufactured: Replacement Parts List No Revision B 07/2001

MDT6N SERVICE PARTS TABLE OF CONTENTS. Cabinet PAGE 2. Hopper PAGE 3. Sink PAGE 4. Ice Chute and Dispensing PAGE 5. Air Cooled Refrigeration PAGE 6

Spare Parts Catalogue MV1006

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

CME1056 Service Parts. Table of Contents

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com

MARVAIR CLASSIC HEAT PUMPS MODELS AVP HP EXPLODED VIEW PARTS ID

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

Roll Heated Flatwork Finisher

UNIT PANELS 6/25/ :15:30 AM Page 2 of 27

SECTION WATER-SOURCE UNITARY HEAT PUMPS

Parts List. Modular Crescent Cuber. Models KM-515MAJ, MWJ, MRJ. hoshizakiamerica.com

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012

CME1856W Service Parts

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

Commercial High-Efficiency Condensing Units

NM1850 SERVICE PARTS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

REPLACEMENT PARTS MANUAL

CMS1402 SERVICE PARTS

Home Stacked Washer/Dryer

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

SKYPAK II Heating & Cooling Self Contained Packages

REPLACEMENT PARTS LIST

Parts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com

MERIT Series R-410A - Upflow / Horizontal

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

SKYPAK II, 3 Ton Series, gives you a

Daikin McQuay. Pathfinder Air Cooled Chiller Screw Compressor Two Circuit. AWS Vintage A

VertiCool Aurora Engineering Guide

CME1856W Service Parts

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

Parts and Service Manual

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

UNIT PANELS 6/25/2014 9:02:04 AM Page 2 of 23

Concealed Ducted Split Series R-407C MBH

MARVAIR COMPAC AIR CONDITIONERS MODELS AVP EXPLODED VIEW PARTS ID

KCC Centrifugal Fan Air Cooled Condensers

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

40LM Hz INSTALLATION, START-UP AND SERVICE INSTRUCTIONS CHILLED WATER FAN COIL UNIT

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

MERIT SERIES Up Flow / Horizontal

MARVAIR MODPAC II AIR CONDITIONERS MODELS AVP EXPLODED VIEW PARTS ID

REPLACEMENT PARTS MANUAL

MERIT Series R-410A - Upflow / Horizontal

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

REPLACEMENT PARTS MANUAL

MARVAIR COMPAC AIR CONDITIONERS MODELS AVP72AC AND AVPA72AC EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS)

Daikin McQuay. Applied PTAC Air Conditioner and Heat Pump. PDAA, PDAE, PDAF, PDAN, PDHA, PDHE, PDHF Design 3

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

SeasonMaker Hi-Line Fan-coil Unit Model HSS S30 through S80

Transcription:

Replacement Parts List No. 055204700 Revision D 01/2017 McQuay Climate Control Horizontal Water Source Heat Pump CC, CG, CW, UC, UG, UW 610-630 Vintages E, F, G Last Manufactured: 1988 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

Contents Parts List Revision History...3 Nomenclature- Model and Catalog Number...4 Nomenclature- Serial Number...5 Refrigeration Circuit- Diagram...6 Chassis, Sheet Metal, Blower Section, Refrigeration Section- Diagram...7,8 Chassis, Sheet Metal, Blower Section, Refrigeration Section- Components... 9-12 Controls- F Series...13,14 Controls- G Series...15,16 Combination Shutoff/Balancing Ball Valve...17 Optional Hanger Kits- UC/UG/UW Only...17 Supply and Return Hoses...17 Return Air Duct Collar...18 Replacement Filters...18 Roll Filter Kits...18 RPL 0552047 / Page 2

Parts List Revision History Revision Date Description NEW 02/91 New. A 09/02 Convert to electronic format and update part numbers to current McQuay Mitrol format. Add reference numbers to refrigeration schematic. Correct Bristol number for size 610 2108/230/3 compressor. Update part numbers for fusible plug, and 208 to 24V transformer. Add new reversing valve and coil part numbers and add footnote regarding replacement of original components. Correct part number for 208/230/1 fan motor. Correct part number and add vendor number for motor pulley. Add "F" and "G" control transformer specifications. Correct part number for size 630 480/575V Units relay. Add note to size 610 compressor capacitors. Add controls layout drawings and separate controls from other unit components. Add reference # 1A to chassis drawing. B 06/04 Page 9 - Bub #1 Compr., 460/60/3 size 610 was H22C563DBEA change to H23A563DBEA. C 06/09 Page 14 - Ref 34 change Transformer p/n unit 630 from 802005465 to 802005955. D 01/17 Rebrand Daikin. Page 9- Delete vendor p/ns. Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330 RPL 0552047 / Page 3

Nomenclature Catalog Number C A P L G S 3 S Family Group C= Ceiling Concealed Unit Unit Type Standard Construction- Units with Water Regulating Valve G= Heat Pump Std./Copper Condenser N= Cooling Only/Copper Condenser P= Heat Pump- Extended Range/Copper Condenser Q= Heat Pump Std./CuNI Condenser R= Cooling Only/CuNI Condenser S= Heat Pump- Extended Range/CuNI Condenser Standard Construction- Units without Water Reg. Valve A= Heat Pump Std./Copper Condenser B= Cooling Only/Copper Condenser C= Heat Pump- Extended Range/Copper Condenser L= Heat Pump Std./CuNI Condenser M= Cooling Only/CuNI Condenser W= Heat Pump- Extended Range/CuNI Condenser Extra Quiet Construction- Units w/ Water Regulating Valve T= Heat Pump Std./Copper Condenser U= Cooling Only/Copper Condenser V= Heat Pump- Extended Range/Copper Condenser X= Heat Pump Std./CuNI Condenser Y= Cooling Only/CuNI Condenser Z= Heat Pump- Extended Range/CuNI Condenser Extra Quiet Construction- Units without Water Reg. Valve D= Heat Pump Std./Copper Condenser E= Cooling Only/Copper Condenser F= Heat Pump- Extended Range/Copper Condenser H= Heat Pump Std./CuNI Condenser J= Cooling Only/CuNI Condenser K= Heat Pump- Extended Range/CuNI Condenser Packaging Specification Always S Air Handling System 3= Direct Drive with AAV 4= 2-Speed Motor without AAV S= Belt Drive, Standard Motor Controls S= Standard Offering I= Random Start (Electromechanical Controls) R= Less Controls (Remote Panel Required) Design Series (Vintage) Nominal Capacity K= 61000 btu L= 63000 btu Voltage D= 240/60/3 K= 208/60/3 L= 575/60/3 P= 480/60/3 Model Number C C 610 G 88 Family Group C= Ceiling Concealed Unit- Horizontal Discharge U= Ceiling Concealed Unit- Vertical Discharge Unit Type C= Ext. Range Heat Pump, Copper Condenser G= Cooling Only, Copper Condenser W= Water Source Heat Pump Nominal Capacity in hundreds of btus Design Series (Vintage) E= Solid State Controls F= Electromechanical Controls G= Solid State Controls- Mark III Version 2 System Voltage 02= 120/60/1 03= 240/60/1 05= 208/60/1 07= 277/60/1 33= 240/60/3 48= 380/220/50/3 55= 208/60/3 66= 575/60/3 87= 480/277/60/3 88= 480/60/3 RPL 0552047 / Page 4

Nomenclature Serial Number (1983 thru May, 1986) 43 5 25 0032 Unit Type 43= CC Unit Year Manufactured 3= 1983 5= 1985 4= 1984 6= 1986 Serial Number Week Manufactured 01-52 Serial Number (May, 1986 thru 1988) 7 R A 12345 01 Manufacturing Plant Identification 7 = Auburn Year Manufactured R= 1986 S= 1987 T= 1988 Engineering Revision level Serial Number Month Manufactured A = January B = February C = March D = April E = May F = June G = July H = August J = September K = October L = November M = December RPL 0552047 / Page 5

Refrigeration Circuit Diagram 10 Capillary (7) 7 Evaporator Coil High Pressure Switch 4 9 Reversing Valve Low Pressure Switch 5 Compressor 1 6 Fusible Plug Condenser Coils 14 RPL 0552047 / Page 6

Chassis, Sheet Metal, Blower Section, Refrigeration Section Diagram (CC/CG/CW Belt Drive Shown) See Controls Section 31 46 2 3 59 55 56 54 32 48 12 10 13 11 45 47 8 7 52 53 58 57 9 49 50 14 5 6 44 4 1 1A 57 52 51 22 43 53 29 28 27 26 24 16 25 15 17 23 18 19 20 21 42 30 Belt Drive 69 66 67 CC/CG/CW Direct Drive Blower Section 60 Direct Drive 68 61 63 62 64 65 RPL 0552047 / Page 7

Chassis, Sheet Metal, Blower Section, Refrigeration Section Diagram, Continued 31 UC/UG/UW Belt Drive Blower Section 21 20 19 15 22 17 16 30 29 27 25 18 23 60 28 26 24 UC/UG/UW Direct Drive Blower Section 23 61 65 64 22 66 67 69 68 30 RPL 0552047 / Page 8

Chassis, Sheet Metal, Blower Section, Refrigeration Section Components 1 1 Compressor 208/230/60/1 802003412 208/230/60/1 0001223513 208/230/60/3 802003405 208/230/60/3 802003409 460/60/3 802003406 460/60/3 802003410 575/60/3 802003407 575/60/3 802003411 1A 4 Compressor Grommet 802003084 802003084 2 1 Capacitor- Compressor 1 30MFD/ 370V 802007848 N/A 25MFD/440V 802007855 802007855 3 1 Capacitor- Compressor 1 40MFD/ 370V 802007850 N/A 30MFD/440V 802007856 802007856 4 1 High Pressure Switch 802005813 802005813 5 1 LP Switch- Discharge Line (G Vint. Only) 802026139 802026139 N/S 1 Low Pressure Switch- Suction Line 803005111 803005111 6 1 Fusible Plug 106057401 106057401 Fitting for Fusible Plug 802025013 802025013 7 1 Reversing Valve 067307401 2 067307401 2 8 1 Coil- Reversing Valve Vintage F Units- 208/230V 066541903 2 066541903 2 Vintage G Units- 24V 066541901 2 066541901 2 9 1 Evaporator Coil 802004279 N/S 2 Seal- Evaporator Coil 802051105 802053067 1 Any of these capacitors may have been installed. Check original capacitor specification to choose proper replacement. 2 Ranco has redesigned their reversing valves. The valve and coil part numbers listed above reflect the new part numbers. If replacement of either part is necessary and the original design valve is installed, both parts must be replaced simultaneously. Old Coils do not fit new valves, and new coils do not fit old valves. RPL 0552047 / Page 9

Chassis, Sheet Metal, Blower Section, Refrigeration Section Components, Continued 10 7 Capillary Assembly 802001150 802001150 11 1 Strainer 802025529 802025527 12 4 Capillary 802001157 802001168 13 1 Valve- Check 802026189 802026189 14 2 Condenser Coil- Copper (standard) 802004274 802004274 2 Condenser Coil- CuNI 802004289 802004289 15 1 Motor- Blower 208/230/60/1 C239 4 C239 4 208/230/460/60/3 802024267 4 802024267 4 575/60/3 802024285 4 802024285 4 16 1 Motor Pulley- 1VL40 X 5/8" 028815300 4 028815300 4 17 1 Bracket Adjustment- CC/CG/CW 850011382 4 850011382 4 Bracket Adjustment- UC/UG/UW 850015375 4 850015375 4 18 1 Motor Mount 850011386 4 850011386 4 19 1 Housing, Blower- CC/CG/CW 802000108 3,4 802000108 3,4 Housing, Blower- UC/UG/UW 850015423 3,4 850015423 3,4 20 1 Wheel- Blower 802000123 3,4 802000123 3,4 21 1 Cut Off 802000118 3,4 802000118 3,4 22 1 Left Hand Bracket, Blower- CC/CG/CW 850012644 4 850012644 4 Left Hand Bracket, Blower- UC/UG/UW 850015406 4 850015406 4 23 1 Left Hand Bracket, Blower- CC/CG/CW 850012643 4 850012643 4 Left Hand Bracket, Blower- UC/UG/UW 850015405 4 850015405 4 24 1 Shaft- Blower Wheel 802023117 3,4 802023117 3,4 25 2 Bracket- Bearing 802023042 3,4 802023042 3,4 26 2 Bearing- Blower Wheel Shaft 802023036 3,4 802023036 3,4 3 Included in Complete Blower Assembly (CC/CG/CW only) pn: 802000122. 4 Belt Drive Units Only. RPL 0552047 / Page 10

Chassis, Sheet Metal, Blower Section, Refrigeration Section Components, Continued 27 2 Eccentric Collar 802023061 4 802023061 4 28 1 Pulley- Blower- AK66 X 1" 802023093 4 802023093 4 29 1 Belt- CC/CG/CW 802023094 4 802023094 4 Belt- UC/UG/UW 802023105 4 802023105 4 30 1 Panel, Blower- CC/CG/CW 850012635 4 850012635 4 Panel, Side- UC/UG/UW 850015421 4 850015421 4 31 1 Cover, Top- CC/CG/CW 850012631 4 850012631 4 1 Cover, Top- UC/UG/UW 850015418 4 850015418 4 42 1 Corner Post- Left Hand Rear 850012634 850012634 43 1 Base Pan 850012621 850012621 44 2 Support- Condenser Coil 850012642 850012642 45 1 Cover- Condenser Coil 850012636 850016697 46 1 Bulkhead 850012637 850016696 47 1 Bulkhead- Evaporator 850012638 850016695 48 1 Cover- Evaporator Coil 850013156 850013156 49 1 Air Block- Evaporator Coil 850012646 850012646 50 1 Drain Pan 850013142 850013142 51 2 Corner Post- Right Hand Front 850012632 850012632 52 1 Bracket- End Panel 850012641 850012641 53 1 Panel- End 850012640 850012640 54 1 Corner Post- Left Hand Front 850012633 850012633 4 Belt Drive Units Only. RPL 0552047 / Page 11

Chassis, Sheet Metal, Blower Section, Refrigeration Section Components, Continued 55 1 Panel- Electrical Access 850012629 850012629 56 1 Panel- Electrical Access Accessories 850012630 850012630 57 2 Bracket, End- Filter 850013232 850013232 58 2 Bracket, Top and Bottom- Filter 850013233 850013233 59 2 Filter, Throwaway- 22" X 20" X 1" 802008097 802008097 60 1 Panel, Blower- CC/CG/CW Direct Drive 850014164 850014164 Panel, Top- UC/UG/UW Direct Drive 850015419 850015419 61 1 Housing, Blower- Direct Drive 802000099 802000099 62 1 Air Vane- Direct Drive 850008565 850008565 63 1 Adjustment Rod- Direct Drive 802023109 802023109 64 1 Wheel, Blower- Direct Drive 802000125 802000125 65 1 Cut Off Plate- Direct Drive 850009021 850009021 66 1 Motor Mount- Direct Drive 802009144 802009144 67 1 Motor- Direct Drive 208 Volt 802024362 802024362 230 Volt 802024363 802024363 460 or 575 Volt 802024361 802024361 68 1 Capacitor- Direct Drive 802007889 802007889 69 1 Terminal Board- Direct Drive 802007056 802007056 RPL 0552047 / Page 12

Controls- F Series Diagram 34 Transformer 32 33 Terminal Board Compressor Contactor 37 Terminal Block 40 Relay 36 Anti- Short Cycle Timer 35 Time Delay Relay Relay 38 39 RPL 0552047 / Page 13

Controls- F Series Components 32 1 Control Box 850012624 850012624 33 1 Terminal Board 802007932 802007932 34 1 Transformer 50VA, 208-24V 060614101 060614101 40VA, 240-24V 802005465 802005955 50VA, 480-24V 060676001 060676001 35 1 Timer- Anti Short Cycle 802005917 802005917 36 1 Relay 802005691 802005691 37 1 Contactor- Compressor 1Ø Units 802005547 802005547 3Ø Units 802005198 802005198 38 1 Relay- Time Delay 802005906 802005906 39 1 Relay 802005656 802005656 40 1 Terminal Block 802007683 802007683 N/S 1 Sensor- Condensate Overflow 850012260 850012260 RPL 0552047 / Page 14

Controls- G Series Diagram 34 Transformer 32 33 Terminal Board Compressor Contactor 37 Terminal Block 41 Relay 39 35 36 Fan Relay 38 RPL 0552047 / Page 15

Controls- G Series Components 32 1 Control Box 850012624 850012624 33 1 Terminal Board 802007932 802007932 34 1 Transformer 50VA, 208-24V 060614101 060614101 40VA, 240/480-24V 802005465 802005465 50VA, 575-24V 802005955 802005955 35 1 Bracket- Mark III PC Board 850012628 850012628 36 1 PC Board- Mark III (Version 2) 803007090 803007090 37 1 Contactor- Compressor 208/230/60/1 Units 802005879 802005879 208/230/460/575/60/3 Units 027514201 027514201 208/60/3 803005096 803005096 38 1 Relay- Fan 802005209 802005205 4 39 1 Relay 803005081 803005081 41 1 Terminal Block 802007683 802007683 N/S 1 Sensor- Condensate Overflow 850012260 850012260 N/S 1 Right Angle- PC Board Edge 802007546 802007546 N/S 1 Fuse Holder 802007715 802007715 N/S 1 Fuse- with insulated knob 802007714 802007714 4 Used on 480V or 575V units only. RPL 0552047 / Page 16

Supply and Return Hoses N/S 2 Non- Fire Rated 2 foot 802025414 802025414 3 foot 802025415 802025415 4 foot 802025416 802025416 5 foot 802025417 802025417 6 foot 802025418 802025418 7 foot 802025419 802025419 8 foot 802025420 802025420 9 foot 802025421 802025421 10 foot 802025422 802025422 N/S 3 Fire Rated 2 foot 802025611 802025611 3 foot 802025612 802025612 4 foot 802025613 802025613 5 foot 802025614 802025614 6 foot 802025615 802025615 7 foot 802025616 802025616 8 foot 802025617 802025617 9 foot 802025618 802025618 10 foot 802025619 802025619 Combination Shutoff/Balancing Ball Valve N/S 2 1" FPT 802026109 802026109 Optional Hanger Kits- UC/UG/UW Only N/S 2 Hanger Kit 859004252 859004252 RPL 0552047 / Page 17

Return Air Duct Collar N/S 2 Return Air Duct Collar Contact McQuay Replacement Filters N/S 1 1" Throwaway Type 802008097 802008097 N/S 1 2" Throwaway Type 802008107 802008107 N/S 1 1" Cleanable Aluminum Type 802008102 802008102 Roll Filter Kits N/S 1 Assembly (less crank and media) 802008083 802008083 N/S 30 ft. Filter Media- Roll Form 802008113 802008113 N/S 1 Crank- Manual Advance 859004216 859004216 RPL 0552047 / Page 18