Low Flow Unit Coolers

Similar documents
Lo-Aire Unit Coolers. Technical Guide. bn-lftb May Models LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost.

Center Mount Unit Coolers

Low Velocity Center Mount Unit Cooler. Technical Guide. Models LWA - Air Defrost LWE - Electric Defrost LWG - Hot Gas Defrost.

Low Profile Unit Coolers

Low Profile Unit Coolers

LOW PROFILE UNIT COOLER. Technical Guide. Models RLC Air Defrost ELC/EFC Electric Defrost GLC Hot Gas Defrost. CH-LOPTB May,

Slim Contour Unit Cooler

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

LOW PROFILE UNIT COOLER

LOW PROFILE UNIT COOLER

Packaged refrigeration system Technical Guide

Super-Flo Low Profile Unit Cooler

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

PRO 3 TOP MOUNT & SIDE MOUNT PACKAGED REFRIGERATION SYSTEMS Technical Guide

T H I N K I N S I D E T H E B o x

Compak Unit Coolers. LCA - Air Defrost LCE - Electric Defrost LCH - Hot Gas Defrost. Bulletin LC-03A August 2004 (Replaces LC-03 3/03)

Air-Cooled Condensing Units with Screw Compressors. Technical Bulletin Low Temperature Models SSV DSV

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

Air-Cooled Condensers

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

PRODUCT. TWB Two-Way Air Defrost Unit Coolers PRODUCT DATA & INSTALLATION. High Temperature (35 o F / 1.7 o C or Higher) Applications

KTL Two-Way Low Profile Evaporators

KR Series COMPACT UNIT COOLERS. Technical Bulletin: KRUC_005_ Products that provide lasting solutions.

High Profile Evaporator

Reach-In Unit Coolers. Technical Guide. Models TA TL C VA BBM BBL KMK RAMK BTO U. LK-RITB June

Air-Cooled Condensing Units with Compact Screw Compressors

Packaged Refrigeration Systems

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_001_ Products that provide lasting solutions.

Low Profile Unit Cooler. ECM Motors. All-Temp²B. Small to Medium Walk - Ins. Coolers & Freezer Applications. Now available with optional

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.

KTL Two-Way Low Profile Unit Coolers

BTL Two-Way Low Profile Evaporators

SM/SV Series PRODUCT COOLERS. Technical Bulletin: SMSV_005_ Products that provide lasting solutions.

SM/SV Series PRODUCT COOLERS. Technical Bulletin. Products that provide lasting solutions.

horizontal air discharge outdoor discus condensing unit

Your Climate. We're There. TM: MDB B 2140B. Ducted Split Systems. Models: MDB 075B - MDB750B MDB 075B/B - MDB500BR. Air Conditioning REGISTERED

BN-ACCMX MAR 2016 Replaces BN-TB-ACCMX MAR Air-Cooled Condenser. with Microchannel Coil Technology Models NRG NRJ

KR Series Air Defrost Unit Coolers Operating and Installation Manual

BN-HGDTB June Replaces BN-HGDTB, March Mohave. Technical Guide

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

KR Electrical Defrost Unit Coolers (PN E108318_E)

Installation, Operation, and Maintenance Information

LK-TSSTB July 2009 FPO HP Two Stage Condensing Units and Systems Technical Guide. with Bitzer Compressors.

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Air-Cooled Condensers

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

Page ` RLP R1. Supersedes all earlier versions LIST PRICES April, 2018

EMI ENGINEERING SUBMITTAL

Commercial High-Efficiency Condensing Units

VERTICAL FAN COIL UNITS

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

Specifications and Performance S2H

MH1WC4W-06-1-B Chilled/Hot Water 1-Way Cassette Fan Coil

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Unit Coolers Evaporator & Condenser Coils Aluminum Extrusion Heat Transfer Products

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

ACNF Series. Ceiling-Mount Air Handlers 1½ to 2½ Tons

TLV Low Velocity Evaporators

Product Specifications. Vertical Floor Consoles By First Co.

3-22 HP CONDENSING UNITS Technical Guide

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

RSG16**S1M. Split System Air Conditioner 16 SEER

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Page ` RLP A. Supersedes all earlier versions LIST PRICES Prices effective 7/2/18

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

LIST PRICES SEE THE BACK COVER FOR "CONDITIONS OF SALE AND WARRANTY"

CFFWA4P-16-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 48,000 BTUH

CFFWA4P-12-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 36,000 BTUH

HiLine Vertical Stacking Fan Coils. Type FHSS and FHSK. Catalog

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

RTG Ultron. Up to 16 SEER. Specification Sheet. Split System Heat Pump

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Industrial Unit Coolers

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

RLP Page. Prices effective January 1, Supersedes all earlier versions LIST PRICES

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

MACH N-407 Heat Pump Air-Cooled Chiller

EMI ENGINEERING SUBMITTAL

Reach-In Unit Coolers: ASL 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

Today s Value-Added Performers. The DRY-30 Series Dehumidifiers from DryAire Systems.

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

CWA4 Chilled & Hot Water Fan Coil

Today s Value-Added Performers. The DRY-40A Series Dehumidifiers from DryAire Systems.

Installation, Start-Up and Service Instructions

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

G Series. G Series Air Coils Installation ti Manual ENCASED/UNCASED AIR COILS. Geothermal/Water Source Heat Pumps R-410A Refrigerant 2-5 Ton

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

ACNF Series. Ceiling-Mounted Air Handlers 1½ to 2½ Tons

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

Transcription:

BN-LFTB October 2016 Replaces BN-LFTB APR 2015 Low Flow Unit Coolers Technical Guide s LO Air Defrost LOD Electric Defrost LOG Hot Gas Defrost

Table of Contents Nomenclature...2 Features & Benefits...3 Performance Data All Defrost Types...4 Specifications Air Defrost...5 Electric Defrost...5 Hot Gas Defrost...5 Dimensional Data...6 Replacement Parts by InterLink...6 Physical Data...7 Standard Nozzle Selection...7 Choose the most energy-efficient motor available for evaporators. The EC motor is an energy efficient option on BOHN Low Flow Unit Coolers. Available on all new equipment or as an easy-to-install, drop-in replacement aftermarket part from InterLink Commercial Refrigeration Parts. Because they are a drop-in replacement for existing shaded pole and PSC motors, installation is quick and easy. It s a high impact, quick payback solution for reducing costs and achieving green initiatives without replacing the entire system. EC motors by InterLink are up to 75% energy efficient - that s a 51-59% increase over shaded pole motors and a 30-35% increase over permanent-split capacitor (PSC) motors. With all of this added efficiency, you can count on more energy savings and lower operational costs while taking a step in the right direction toward conserving our planet s resources. Nomenclature LO 070 A E Series Capacity Electrical Code Design Revision 2 2 LO = Bohn Low Flow, air defrost # x 100 = BTUH A = 115/1/60 LOD = Bohn Low Flow, electric defrost B = 208-230/1/60 LOG = Bohn Low Flow, hot gas defrost AH = 115/1/60 (PSC) BH = 208-230/1/60 (PSC) MH = 460/1/60 (PSC) AE = 115/1/60 (EC) BE = 208-230/1/60 (EC)

Features & Benefits Low Flow unit coolers are ideal for meat storage and preparation rooms, floral coolers, dough retarding and many other applications requiring low air velocities and low sound levels. With low velocity unit coolers, high humidities can be maintained to prevent product drying and weight loss. These units are ideal for any type of workroom where human comfort is important. Cabinet Rust-free, all-aluminum white case with louvered intake grille for attractive appearance Statically and dynamically balanced fans are designed for quiet air movement All factory installed electrical components are wired to a terminal board in the junction box making field wiring quick and easy Inlet connection allows for external mounting of TXV Coil Sweat-type cooling coil connections reduce the potential for leaks Nickel-steel alloy heaters provide a positive defrost and have long life Electric defrost coils have a hermetically sealed defrost termination thermostat that does not require adjustment. Hot gas defrost units come with an adjustable defrost termination thermostat Cross-fin cooling coils with corrugated aluminum fins spaced 6 FPI & 3/8 OD staggered copper tubes provide optimum heat transfer and reduce the amount of refrigerant required Generous coil surface helps to maintain steady room temperature and minimize product shrinkage Access port on the suction connection allows superheat to be easily and accurately set Drain Pan Hot gas models use inner drain pans with low-wattage electric heaters. This eliminates the braze joints and tubing associated with hot gas drain pan loops All models use inner drain pans to reduce sweating Motors Motors are factory-wired to unit junction box for fast installation Thermal overload protected motors are resiliently mounted inside the unit to assure minimum noise level High efficiency PSC motors are optional on sizes 070 through 165. PSC motors are standard on sizes 189 through 266 EC Motors (optional) available factory-installed or as a drop-in replacement through InterLink Commercial Refrigeration Parts in 115/1/60 and 208-230/1/60 Options Units available with copper fins. Air defrost units also available with polyester coated fins or various coil coatings options Factory installed mounted components are available in these configurations: s Pre-assembled units come with mounted TXV, liquid line solenoid valve and room thermostat s Pre-charged units come with mounted TXV, liquid line solenoid valve, room thermostat, and quick connect fittings s Mounted TXV s Mounted TXV and solenoid valve s Mounted room thermostat 3 3

PERFORMANCE DATA Lo/LoD/LoG Air/Electric/Hot Gas Defrost 60 Hz 10 F TD 25 F SST 6 C TD -4 C SST 15 F TD 25 F SST Capacity 8 C TD -4 C SST 20 F TD 25 F SST BTUH Watts BTUH Watts BTUH Watts Fan Data 10 C TD -4 C SST No. CFM m 3 h LO*070 7,000 2,050 10,500 3,075 14,000 4,100 2 1,200 2,040 LO*087 8,700 2,550 13,050 3,822 17,400 5,100 2 1,200 2,040 LO*118 11,800 3,460 17,700 5,183 23,600 6,910 2 1,300 2,210 LO*125 12,500 3,660 18,750 5,490 25,000 7,320 2 1,300 2,210 LO*150 15,000 4,390 22,500 6,590 30,000 8,790 2 1,900 3,230 LO*165 16,500 4,830 24,750 7,250 33,000 9,670 2 1,900 3,230 LO*189 18,900 5,540 28,350 8,300 37,800 11,070 2 2,400 4,080 LO*225 22,500 6,590 33,750 9,890 45,000 13,180 2 2,700 4,590 LO*266 26,600 7,790 39,900 11,690 53,200 15,580 2 3,200 5,440 Lo/LoD/LoG Air/Electric/Hot Gas Defrost 50 Hz Capacity Fan Data 10 F TD 6 C TD 15 F TD 8 C TD 20 F TD 10 C TD 25 F SST -4 C SST 25 F SST -4 C SST 25 F SST -4 C SST No. CFM m 3 h BTUH Watts BTUH Watts BTUH Watts LO*070 6,390 1,870 9,588 2,810 12,780 3,740 2 1,085 1,846 LO*087 7,950 2,330 11,917 3,490 15,900 4,660 2 1,085 1,846 LO*118 10,780 3,160 16,162 4,730 21,560 6,320 2 1,176 1,999 LO*125 11,420 3,350 17,123 5,020 22,840 6,690 2 1,176 1,999 LO*150 13,700 4,010 20,546 6,020 27,400 8,030 2 1,719 2,922 LO*165 15,070 4,410 22,601 6,620 30,140 8,830 2 1,719 2,922 LO*189 17,260 5,060 25,888 7,580 34,520 10,110 2 2,171 3,691 LO*225 20,550 6,020 30,819 9,030 41,100 12,040 2 2,443 4,153 LO*266 24,290 7,120 36,433 10,670 48,580 14,230 2 2,895 4,922 4 4

PERFORMANCE DATA Lo Air Defrost Shaded Pole Motor PSC Motor EC Motor 115/1 208-230/1 115/1 208-230/1 460/1 115/1 208-230/1 Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts LO070 3.6 232 2.4 244 1.64 160 1.0 196 1.8 57 1.0 59 LO087 3.6 232 2.4 244 1.64 160 1.0 196 1.8 57 1.0 59 LO118 3.6 232 2.4 244 1.64 160 1.0 196 1.8 57 1.0 59 LO125 3.6 232 2.4 244 1.64 160 1.0 196 1.8 57 1.0 59 LO150 3.6 232 2.4 244 1.64 160 1.0 196 1.8 57 1.0 59 LO165 3.6 232 2.4 244 1.64 160 1.0 196 1.8 57 1.0 59 LO189 2.80 230 1.40 230 0.8 288 5.5 316 2.8 290 LO225 2.80 230 1.40 230 0.8 288 5.5 316 2.8 290 LO266 2.80 230 1.40 230 0.8 288 5.5 316 2.8 290 LoD Electric Defrost Shaded Pole Motor PSC Motor EC Motor Defrost Heaters 208-230/1 208-230/1 460/1 208-230/1 208-230/1 460/1 Watts Amps Watts Amps Watts Amps Watts Amps Watts Total Amps LOD070 2.4 244 1.0 196 1.0 59 2,650 11.5 LOD087 2.4 244 1.0 196 1.0 59 2,650 11.5 LOD118 2.4 244 1.0 196 1.0 59 3,850 16.7 LOD125 2.4 244 1.0 196 1.0 59 3,850 16.7 LOD150 2.4 244 1.0 196 1.0 59 3,850 16.7 LOD165 2.4 244 1.0 196 1.0 59 3,850 16.7 LOD189 1.40 230 0.8 288 2.8 290 4,770 20.7 10.4 LOD225 1.40 230 0.8 288 2.8 290 5,700 24.8 12.4 LOD266 1.40 230 0.8 288 2.8 290 5,700 24.8 12.4 LoG Hot Gas Defrost Shaded Pole Motor PSC Motor EC Motor Drain Pan Heaters 115/1 208-230/1 115/1 208-230/1 460/1 115/1 208-230/1 208-115/1 Watts 230/1 460/1 Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Amps Watts Total Amps LOG070 3.6 232 2.4 244 1.64 196 1.0 196 1.8 57 1.0 59 660 5.8 2.9 LOG087 3.6 232 2.4 244 1.64 196 1.0 196 1.8 57 1.0 59 660 5.8 2.9 LOG118 3.6 232 2.4 244 1.64 196 1.0 196 1.8 57 1.0 59 960 8.4 4.2 LOG125 3.6 232 2.4 244 1.64 196 1.0 196 1.8 57 1.0 59 960 8.4 4.2 LOG150 3.6 232 2.4 244 1.64 196 1.0 196 1.8 57 1.0 59 960 8.4 4.2 LOG165 3.6 232 2.4 244 1.64 196 1.0 196 1.8 57 1.0 59 960 8.4 4.2 LOG189 2.80 230 1.4 230.08 288 5.5 316 2.8 290 1,190 10.4 5.2 2.6 LOG225 2.80 230 1.4 230.08 288 5.5 316 2.8 290 1,426 12.4 6.2 3.1 LOG266 2.80 230 1.4 230.08 288 5.5 316 2.8 290 1,426 12.4 6.2 3.1 5 5

DIMENSIONAL DATA LO = Air Defrost LOD = Electric Defrost LOG = Hot Gas Defrost Dimensional Data For All s Dimensions A B C D E F G in. mm in. mm in. mm in. mm in. mm in. mm in. mm LO*070 83 2108 49 1245 17 432 14 356 22 559 19-1/2 495 23-1/4 591 LO*087 83 2108 49 1245 17 432 14 356 22 559 19-1/2 495 23-1/4 591 LO*118 111 2819 38-1/2 978 17 432 14-1/2 368 22 559 19-1/2 495 23-1/4 591 LO*125 111 2819 38-1/2 978 17 432 14-1/2 368 22 559 19-1/2 495 23-1/4 591 LO*150 114 2896 38-1/2 978 18-1/2 470 16 406 22 559 19-1/2 495 23-1/4 591 LO*165 114 2896 38-1/2 978 18-1/2 470 16 406 22 559 19-1/2 495 23-1/4 591 LO*189 134 3404 48-1/2 1232 18-1/2 470 16-1/2 419 22 559 19-1/2 495 23-1/4 591 LO*225 153 3886 58 1473 18-1/2 470 16-1/2 419 22 559 19-1/2 495 23-1/4 591 LO*266 158 4013 58 1473 21 533 20 508 27 689 24-1/2 622 28-1/4 718 Replacement Parts Commercial Refrigeration Parts Right source. Right parts. Right now. InterLink is your link to a complete line of dependable and certified commercial refrigeration parts, accessories and innovative electronic controls for all Bohn equipment. At InterLink, we provide our wholesalers with a comprehensive selection of product solutions and innovative technologies for the installed customer base. And every product is built to ensure the same high performance standards with which all Heatcraft Refrigeration Products (HRP) brands are built backed by a dedicated team to serve every customer need, delivering at the best lead times in the industry. Dependable. Versatile. Courteous. Finally, one simple source for all your replacement needs from a name you can trust. For parts, please contact (800) 686-7278 or visit www.heatcraftrpd.com. Motors Part # Description 4267W LOG Defrost Termination / Fan Delay Thermostat 22592801 Terminal Strip 28906601 Defrost Termination / Fan Delay Thermostat 2697490 Drain Fitting: Adapter 269151011 Drain Fitting: Locknut 5469 Drain Fitting: Washer 26914901 Drain Fitting Fan Blade Motor Mount Drain Pan Defrost Heater Filters LO*070 22900601 2316597 4040170 2470063 89900801 LO*087 22900601 2316597 4040170 2470063 89900801 LO*118 22900601 2316597 4040171 2470130 89900801 LO*125 22900601 2316597 4040171 2470130 89900801 LO*150 22900701 2316598 4040171 2470130 89900802 LO*165 22900701 2316598 4040171 2470130 89900802 LO*189 2291240 4000111 4040172 2470160 89900802 LO*225 2291240 4000111 4040174 2470200 89900802 LO*266 2291624 4000112 4040173 2470200 89900803 6 6 Part # 115V SP 230V SP 115V PSC 230V PSC 460V PSC 115V EC 230V EC LO*070 25300101 25300201 25302601 25302501 25317801 25317701 LO*087 25300101 25300201 25302601 25302501 25317801 25317701 LO*118 25300101 25300201 25302601 25302501 25317801 25317701 LO*125 25300101 25300201 25302601 25302501 25317801 25317701 LO*150 25300101 25300201 25302601 25302501 25317801 25317701 LO*165 25300101 25300201 25302601 25302501 25317801 25317701 LO*189 2530688 2530689 25305001 25317601 25317501 LO*225 2530688 2530689 25305001 25317601 25317501 LO*266 2530688 2530689 25305001 25317601 25317501

DIMENSIONAL DATA Lo/LoD/LoG Connections OD (in.) Approx. Net Weight Inlet Suction Hot Gas lbs. kg LO = Air Defrost LOD = Electric Defrost LOG = Hot Gas Defrost LO*070 1/2 7/8 1/2 178 81 LO*087 1/2 7/8 1/2 189 86 LO*118 1/2 7/8 1/2 262 119 LO*125 1/2 7/8 1/2 264 120 LO*150 1/2 1-1/8 1/2 280 127 LO*165 1/2 1-1/8 1/2 285 129 LO*189 1/2 1-1/8 1/2 298 135 LO*225 1/2 1-1/8 1/2 366 166 LO*266 1/2 1-3/8 5/8 405 184 7/8" inlet on hot gas defrost models Standard Nozzle Selection Lo Air Defrost Distributor Type No. of R-404A* R-407A** OD Length Circuits Nozzle Nozzle in. cm in. cm LO070 3/16 0.5 24 61 2 L-1/2 L-1/3 LO087 3/16 0.5 24 61 2 L-3/4 L-1/2 LO118 3/16 0.5 24 61 4 L-1 L-3/4 LO125 3/16 0.5 24 61 4 L-1 L-3/4 LO150 3/16 0.5 24 61 4 L-1-1/2 L-3/4 LO165 3/16 0.5 24 61 6 L-1-1/2 L-1 LO189 3/16 0.5 24 61 4 L-1-1/2 L-1 LO225 3/16 0.5 24 61 6 L-2 L-1-1/2 LO266 3/16 0.5 30 76 12 L-2 L-1-1/2 LoD Electric Defrost *Also suitable for R-507, R-502, R-134a, R-401A, R-402A, R-448A & R-449A. ** Also suitable for R-407C, R-407F, R-22. Note: Nozzles sized for 90-100 F liquid temperature at expansion valve. Contact Application Engineering for guidance if Liquid temperature is not 90-100 F Evaporator TD is not 10-15 F (room temperature saturated suction temperature) Electric defrost and hot gas models with a saturated suction temperature of 10 F or higher Caution: Refrigeration system will not perform properly without correct nozzle! Distributor Type No. of R-404A R-407A** OD Length Circuits Nozzle* Nozzle in. cm in. cm LOD070 3/16 0.5 24 61 2 L-1 L-3/4 LOD087 3/16 0.5 24 61 2 L-1 L-3/4 LOD118 3/16 0.5 24 61 4 L-1-1/2 L-1 LOD125 3/16 0.5 24 61 4 L-2 L-1 LOD150 3/16 0.5 24 61 4 L-2 L-1-1/2 LOD165 3/16 0.5 24 61 6 L-2-1/2 L-1-1/2 LOD189 3/16 0.5 24 61 4 L-2-1/2 L-1-1/2 LOD225 3/16 0.5 24 61 6 L-3 L-2 LOD266 3/16 0.5 30 76 12 L-4 L-2-1/2 LoG Hot Gas Defrost Distributor Type No. of R-404A R-407A** OD Length Circuits Nozzle* Nozzle in. cm in. cm LOG070 1/4 0.6 24 61 2 L-1 L-3/4 LOG087 1/4 0.6 24 61 2 L-1-1/2 L-3/4 LOG118 1/4 0.6 24 61 4 L-2 L-1 LOG125 1/4 0.6 24 61 4 L-2 L-1-1/2 LOG150 1/4 0.6 24 61 4 L-2-1/2 L-1-1/2 LOG165 1/4 0.6 24 61 6 L-2-1/2 L-1-1/2 LOG189 1/4 0.6 24 61 4 L-3 L-2 LOG225 1/4 0.6 24 61 6 L-4 L-2 LOG266 1/4 0.6 30 76 12 E-4 E-2-1/2 7 7

2175 West Park Place Blvd. Stone Mountain, GA 30087 Phone: 800.537.7775 Fax: 770.465.5900 heatcraftrpd.com Since product improvement is a continuing effort, we reserve the right to make changes in specifications without notice. BN-LFTB-1016 Version 001 2016 Heatcraft Refrigeration Products LLC