Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017

Similar documents
Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

McQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018

Enfinity Console Water Source Heat Pumps 1/2 to 1½ Ton

McQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008

Air Cooled Scroll Compressor Condensing Unit

CCH/CCW, VFC/VFW, MHC/MHW, LVC/LVW

Console Water Source Heat Pumps

Console Water Source Heat Pumps

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016

Daikin McQuay. Applied PTAC Air Conditioner and Heat Pump. PDAA, PDAE, PDAF, PDAN, PDHA, PDHE, PDHF Design 3

McQuay. Applied PTAC Air Conditioner and Heat Pump PDAC, PDAA, PDAE, PDAN, PDAF PDHP, PDHA, PDHE, PDHF Design 1

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016

Daikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017

Climate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982

McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012

McQuay. Unit Ventilators Self-Contained UAED, UAEQ, UAER, UARQ, UERQ, UAZQ, UAZR, UAZS, UAZU, UAZV Designs D (4), E (5)

Installation and Maintenance Manual OM

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018

(EE1500, EE2000, EE2500, EE3000)

Spare Parts Catalogue MV1006

Engineered for flexibility and performance

Operation and Maintenance Manual OM MicroTech III Unit Controller with I/O Expansion Module for Two Compressor Water Source Heat Pumps

REPLACEMENT PARTS MANUAL

Catalog Enfinity Large Horizontal Water Source Heat Pumps with R-410A Refrigerant

CHP/CCP CEILING MOUNTED AIR HANDLER (ALL CAPACITIES) BACK TO INDEX ITEM QTY. DESCRIPTION

CU0415, CU0715 and CU0920 Service Parts

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

SCE170 SERVICE PARTS

Catalog SmartSource Two-Stage Horizontal & Vertical Water Source Heat Pumps

REPLACEMENT PARTS MANUAL

technical guide Water-Cooled Self-Contained Units

Parts List. Modular Crescent Cuber. Models KM-340MAJ, MWJ. hoshizakiamerica.com

Repair Parts List REFRIGERATOR MODEL NUMBER GC20B8C3EB. When requesting service or ordering parts, always provide the following information:

PARTS LIST GEOTHERMAL HEAT PUMPS HRH/HRV & HOT WATER GENERATOR HWG

Daikin McQuay. Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit. AWS Vintage B Unit Revision 0B (Code 62)

Daikin McQuay. Pathfinder Air Cooled Chiller Screw Compressor Two Circuit. AWS Vintage A

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

Enfinity Large Vertical Water Source Heat Pumps with R-410A Refrigerant

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

SpaceKeeper Console (SKC)

REPLACEMENT PARTS LIST

WHIRLPOOL REFRIGERADOR GS2SHGXLQ01

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

Vertical V*B Series Fan Coil Technical Catalog

UNIVERSAL 750 PRE-MIX DISPENSER

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

REPLACEMENT PARTS MANUAL

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

Parts List. Modular Crescent Cuber. Models KM-1100MAJ, MWJ, MRJ. hoshizakiamerica.com

Product Data. Single-Package Horizontally Mounted Water Source Heat Pumps with Electronic

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

REPAIR PARTS LIST REFRIGERATOR. Model No.(s) (White) (Stainless Steel) (Black)

Commercial High-Efficiency Condensing Units

Catalog SmartSource Compact Vertical Water Source Heat Pumps. Model GCV - Vertical Unit Sizes (1/2 thru 6 tons)

Wiring Diagrams DIAGRAM INDEX

General Description. Operation

High Heat COP. High/Low Stage

SCCG50 & SCCP50 Service Parts

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

SERVICE PARTS MANUAL. The ICE Series Undercounter Cubers MODEL-ICEU300, ICEU305

MARVAIR COMPAC AIR CONDITIONERS MODELS AVP72AC AND AVPA72AC EXPLODED VIEW PARTS ID EXTERIOR SHEET METAL (OUTER PANELS)

15 SEER, PACKAGE AIR CONDITIONING UNITS, 2-5 TONS Single Phase, 208/230 V, 60 Hz COOLING

ICEU 36 SPARE PARTS LIST REV. 07/2016

Maverick II Commercial Rooftop Systems 15 to 75 tons

CMS1402 SERVICE PARTS

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Transcription:

Replacement Parts List No. 700013000 Revision M 11/2017 Daikin McQuay Enfinity Console Water Source Heat Pump WMHC, WMHW 007, 009, 012 Design 1 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

Contents Parts List Revision History... 3-4 Nomenclature Serial Number... 5 Model Number... 5-6 Electrical Legend... 7 Blower Fan Assembly... 8 Refrigeration Circuit- Compressor, Condenser, Evaporator, Switch & Valves Diagrams... 9 Components...10-11 Control Box MicroTech III Controls... 12-13 MTIII Control Board Label Location... 14 Field Installed Accessories... 15-17 Critical Parts List... CPL1 WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 2

Parts List Revision History Rev. Date Description NEW 05/09 NEW A 10/09 Page 22- Add retrofit kit p/n 910104352 and retrofit kit p/n 910104353. B 07/10 Title page- Add unit size 007. Change Nomenclature to Code Index AAA. Page 6- Delete Ball Valves and Motorized Valves chart and add new chart. Page 8- Replace page with revised charts. Pages 11-12 Add footnote (*) for color-specific p/ns. Pages 16-21 Add unit size 007 p/ns. Page 22- Add new descriptions for p/ns 668963602, 910104353, 910104352, 6695205010. Add p/ns 669527801 and 669526201. Change Bub #750 to Bub #140. Pages 23, 25 Add size 007 p/ns. Add control box and stand off descriptions. Add Conn H1-9. C 03/12 Page 6- Change Ball Valve, 10 pack p/n 106065102 to 106065110. Add Motorized Valve Kits p/ns 668996001, 668996002, 668996003. Add Motorized Valve Wire Harness Kit p/n 6688995801. Page 12-Ref#100 Add Antique Ivory p/n 6688018010 for Low Sill. Ref#145 Add Antique Ivory p/n 668961603 for High & Low Sill. Ref#160 Add Antique Ivory p/n 668961804 for High & Low Sill. Ref#170 Add Antique Ivory p/n 668962005 for High & Low Sill. Ref#195 Add Antique Ivory p/n 668962205 for High & Low Sill. Page 13- Ref #565 Change panel-front p/n 6687940010 to 668794001. Page 25- Ref#53 Added sensor,suction line temperature (SLTS) p/n 107201601. Ref #24 Change Standoff PC Board p/n 802028115 to 66880301 & Qty to 6. Change Standoff Edge-holder p/n 668395501 to 802028115. CPL1- Add Critical Parts List. D 04/12 Brand Change. Page 4- Update serial Number to current format. Page 16- Change 208/230V motor p/n 667994202 to 668958651. Change 265V motor p/n 667994203 to 668958652 & 115V motor p/n 667994201 to 668958650. CPL1- Change 208/230V motor p/n 667994202 to 668958651. Change motor p/ns. E 04/13 All Pages updated CS6, dwgs and numerous changes done(sheet metal parts deleted). Pages 4-5 Nomenclature changes- C05= F; C11=Y(1st digit); C24= G-N, Y & 1-4 added. Page 6- Add page for Electrical Legend. Pages 7-9 Field Installed Accessories- Delete Motorized Valve p/n 060977401. Add numerous Thermostats, Sensors and Wall Plate (p/ns from IM/OM). Add Consle Damper, Comm. Module Kit and Subbase Kit. Add page & arrange to fit. Pages 11-19 Delete all sheet metal for cabinet and chassis components. Footnote 1 added to Controls (pg18) to contact McQuay Parts for sheet metal p/ns. Ref #205 Change Scroll fan p/n 6687938010 to 668793803. Page 12- Add Digrams for Refrigeration Circuit. Page 13- Change sleeve p/n 668955501 to 669543501. CPL1- Change Scroll Fan p/n 6687938010 to 668793803. Change Rev Valve p/n 106694110 to 910110425 and Solenoid p/n 106694207 to 910110439. F 09/13 Page 8- Add right hand subbase kit p/ns 910111373 & 106796202. G 11/13 Rebrand Daikin. Page 25- Change MTIII I/O Exp p/n 668105701 to 668105702. Change MTIII LonWorks p/n 668105801 to 107293070 and BACnet p/n 668105901 to 107293071. CPL1- Change MTIII I/O Exp, MTIII LonWorks & BACnet. H 07/14 Page 20- Change High Pressure Switch p/n 668803601 to 910117560. I 03/05 Delete cabinet & chassis sheet metal. Numerous changes. Page 9, 11-15- Delete OA Damper, Basic Unit Layout, sheet metal cabinet/chassis components. Page 10- Add motor capacitor p/ns 668003105 & 668003101. Add Cabinet/Chassis Components and footnote 1. Page 11- Change compressor mounting detail drawing. Change Ref#s for Line Weight, condenser, compressor, plug assy, pressure valve & line weight. Page 12- Change Overload p/n 668015811 to 910114861. Pages 14-15 Delete & combine controls pages 21-24. Add MTIII diagrams for 208-230V & 265V. Change Capacitor, relay DPST, SLTS & transformer p/ns. Pages 13-15 Field Installed Accessories moved from pages 7-9. CPL1- Delete comm cards & expansion valves. Add SLTS. J 10/15 Update to Daikin Format. Page 13- Add I/O Board until 08/12 p/n 668105701. Add footnote for MTIII label location. Page 14- Add MTIII Controls Label Location table and footnote. CPL1- Update to Daikin Format. Daikin Applied,13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330 WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 3

Parts List Revision History Rev. Date Description K 04/16 Title Page add Design 2 for 009 265V. Numerous changes. Page 5- Code 2, Add Design 2= 2 (Size 009 265V only). Page 8- Change indoor motor 115V p/n 667994201 to fan assy, rework p/n 668958653. Change motor 208-230V p/n 667994202 to fan assy, rework p/n 668958651. Change motor 265V motor p/n 667994203 to fan assy, rework p/n 668958652. Page 10- Change mount-vib p/n 668955601 to 668805601. Page 13- Add LUI keypad thermostat programmable p/n 668811101 & thermistor p/n 669529401 for TStat Retrofit Kits p/ns 910104353 & 910104352. Page 15-17- Add numerous updates to field Installed accessories. CPL1- Change motors p/n 667994201-667994203 to fan assy, rework p/ns 668958651-668958653. CPL2-Add Design 2 (unit size 009, 265V). L 12/16 Page 8- Change Ref # 280 fan p/n 106646502 to 667996502. Ref#100 Motors- Add footnote #2. Change motor 115V rework p/n 668958653 to p/n 667994201. Change motor 208-230V rework p/n 668958651 to p/n 667994202. Change motor 265V rework p/n 668958652 to p/n 667994203. CPL1-CPL2- Update motors. M 11/17 A new RPL was created for Design 2 components. Page 11- Change High Pressure Switch p/n 910117560 to 910117731. Change reversing valve 007-009 p/n 106694207 to 910198415. CPL1- Update revision. WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 4

Nomenclature Plant Identification AUB = Auburn SLP= San Luis Potosi U= Unit Serial Number AUB U 09 03 35105 Year of Manufacture 09= 2009 10= 2010 etc. Serial Number (build sequence) Week of Manufacture Model Number WMHC 1 012 C E H B T 01 F2 E C Y YY Code 01-02 03 04 05 06 07 08 09 10 11 12 13 14 15 L RPL YYY YYY A D YYY H S Y Code 16 17 18 19 20 21 22 23 24 25 Code 01= Unit Type W= Water Source Heat Pump Code 02= Product Identifier MHC= Wall Mounted Console WSHP, Standard Range MHW= Wall Mounted Console WSHP, Geothermal Range Code 03= Design Series 1= Design 1 Code 04= Unit Size 007= 7000 BtuH Nominal Cooling 009= 9000 BtuH Nominal Cooling 012= 12000 BtuH Nominal Cooling Code 05= Controls B= MicroTech III Unit Controller C= MicroTech III Unit Controller w/ LonWorks D= MicroTech III Unit Controller w/ BACnet F= MicroTech III Unit Controller w/ BACnet-WSHP System Code 06= Voltage A= E= 208-230/60/1 J= Code 07= Cabinet Height H= High Sill L= Low Sill Code 08= Return Air B= Bottom Return Air (High Sill) F= Front Return Air (Low Sill) Code 09= Discharge Air T= Top Discharge Code 10= Blower Motor 01= Standard Code 11= Cabinet Type /Discharge Grille 1st Digit- Cabinet Type A= Flat Top w/12 Extended End Pocket (High Sill) B= Slope Top w/12 Extended End Pocket (High Sill) F= Flat Top S= Slope Top 2nd Digit- Discharge Grille C= Chassis only (no extended end pocket) 1= Bargrille (Anodized Extruded Aluminum) 2= Standard Stamped Louver 3= Multi-Directional Grille 4= Double-Deflection Adjustable Grille (Plastic) Code 12= Cabinet Construction Type A= Fiberglass Insul w/1 Filter Rack- Std E= Indoor Air Quality (IAQ) w/1 Filter RacK Code 13= Water to Refrigerant Heat Exchanger C= Copper Inner Tube/ Steel Outer Tube S= Cupro Nickel Inner Tube/ Steel Outer Tube Code 14= Heating Options 2= 2.5 kw Electric Heat Y= None Code 15= Dehumidification YY= None Code 16= Piping Hand L= Left Hand R= Right Hand Continued on the next page. WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 5

Nomenclature Continued Code 17= Thermostat Control YYY= None R N L Options L= Low Limit Control M= Low Limit Control & Unit-mounted NSB Override Switch P= NSB Override Switch R= Remote Sensor Y= None Programmability N= Non- Programmable P= 7- Day Programmable w/lcd Display Y= None Controls R= Remote S= Wall Mounted Space Sensor w/nsb Override U= Unit Mounted T stat w/lcd Display W= Wall Mounted T stat w/fan Speed Switch Y= None Code 18= Always YYY Code 19= Always YYY Code 20= Refrigerant A= R410a Code 21= Power Connection C= Unit Mounted 20A Plug & Cord D= Unit Mounted 20A Plug & Cord w/ 15A Fused Disconnect Sw E= Unit Mounted 20A Plug & Cord w/ Non-Fused Disconnect Sw Y= None Code 22= Cabinet Electrical 75V= 75VA Transformer YYY= None Code 23= Water Flow Control H= 2-Way Motorized ½ Isolation Valve, High Close-Off Press. N.C. P= 2-Way Motorized ½ Isolation Valve, High Close-Off Press. N.C. & Supply, Return, Bypass Hand Valves & Measureflow Devices R= ½ Supply, Return & Bypass Valves Only W= 2-Way Motorized ½ Isolation Valve, High Close-Off Press. N.C. & Supply, Return & Bypass Hand Valves Y= None Code 24= Color Y= None Cabinet Grille Subbase S= Antique Ivory Oxford Brown Oxford Brown T= Antique Ivory Antique Ivory Oxford Brown B= Antique Ivory Antique Ivory Antique Ivory D= Cupola White Oxford Brown Oxford Brown P= Cupola White Cupola White Oxford Brown E= Cupola White Cupola White Cupola White G= Off White Oxford Brown Oxford Brown F= Off White Off White Oxford Brown H= Off White Off White Off White K= Putty Beige Oxford Brown Oxford Brown R= Putty Beige Putty Beige Oxford Brown L= Putty Beige Putty Beige Putty Beige V= Soft Grey Oxford Brown Oxford Brown J= Soft Grey Soft Grey Oxford Brown N= Soft Grey Soft Grey Soft Grey Cabinet Subbase 1= Antique Ivory Oxford Brown 2= Antique Ivory Antique Ivory 3= Cupola White Oxford Brown 4= Cupola White Cupola White Code 25= Outside Air Y= None Code 26= Agency Type Code 27= Packaging Code 28= Extended Warranty Code 29= Product Style 1= Style 1 WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 6

Electrical Legend Schematic Sym. BNM C1 C2 CC CM COS CR DAT DPG EWT FHS FSR FSS HP IOEXP LED1 LED2 LWT MIII OVL R1 R2 RAT RV SLTS T1 TB1 UMT X1 Description BACnet Module Capacitor- Compressor Capacitor- Fan Contactor- Compressor Compressor Motor Sensor- Condensate Overflow Relay- Compressor Sensor- Discharge Air Drain Pan Ground Sensor- Entering Water Relay- Fan High Speed Relay- Fan Speed Switch- Fan Speed Switch- High Pressure I/O Expansion Board/Harness LED Annunciator/Harness LED Annunciator/Harness Sensor- Leaving Waters MicroTech III Main Board Compressor Overload Protector Relay- Fan Motor Relay- Electric Heat Sensor- Room Air Valve- Reversing Sensor- Suction Line Temperature EG2UCP Terminal Strip Power Terminal Block Thermostat- Unit Mounted Transformer WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 7

Blower Fan Assembly Motor, Wheel, Fan Housing 300 280 205 100 Cabinet/Chassis components 140 007 009 012 Ref. No. Part Description Part Number 208-230/601 26 208-230/601 208-230/601 100 Motor 2 667994201 1 1 1 Motor 2 667994202 1 1 1 Motor 2 667994203 1 1 1 N/S Capacitor, 4.0 MFD 370V 668003105 1 1 1 Capacitor, 1.5 MFD 370V 668003101 1 1 1 1 1 1 140 Bracket, Motor Mount 668006917 1 1 1 1 1 1 1 1 1 205 Fan Housing, Scroll 668793803 1 1 1 1 1 1 1 1 1 280 Fan, Tangential 667996502 1 1 1 1 1 1 1 1 1 300 Bearing Plate 668002701 1 1 1 1 1 1 1 1 1 N/S Drain Pan 668802701 1 1 1 1 1 1 1 1 1 N/S Cabinet/Chassis components 1 1 1 1 1 1 1 1 1 1 N/S= Not Shown. 1 Please contact Daikin Applied with unit model and serial number for part numbers on Cabinet/Chassis components. 2 Each motor has six (6) terminal pins p/n 034247401 and one (1) Plug Housing p/n 4EFA9389. WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 8

Refrigeration Circuit Compressor, Condenser, Evaporator, Switch & Valves Diagrams Evaporator Coil/ TXV Detail 92 400 Condenser Detail 750 205 71 69 Compressor 137 Reversing Valve Piping Coremax Valve Assy 58 57 61 Compressor Mounting Detail 842 110 TXV Bulb 160 840 Coremax Valve Assembly Detail Low Temperature Sensor Bulb 151A 151B 151C WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 9

Refrigeration Circuit Compressor, Condenser, Evaporator, Switch & Valves Components Unit Size 007 009 012 Ref Part Part No. Description Number 57 Sleeve, Compressor Mount 669543501 3 3 3 3 3 3 3 3 3 58 Nut, Compressor Mount (until 11/15) 063060601 3 3 3 3 3 3 3 3 3 Nut, Compressor Mount (11/15 & later) 802012035 3 3 3 3 3 3 3 3 3 61 Grommet, Compressor Mount 668955401 3 3 3 3 3 3 3 3 3 69 Compressor 7000 BTUH 668803001 1 Compressor 7000 BTUH 668803011 1 Compressor 7000 BTUH 668803021 1 Compressor 8000 BTUH 668951401 1 Compressor 8000 BTUH 668951411 1 Compressor 8000 BTUH 668951412 1 Compressor 10000 BTUH 668951504 1 Compressor 10000 BTUH 668951501 1 Compressor 10000 BTUH 668951503 1 N/S Overload, Compressor until 3/13 668015811 1 Overload, Compressor 3/13 & later 910114861 1 Overload, Compressor 668015816 1 Overload, Compressor 668015814 1 Overload, Compressor 668015802 1 Overload, Compressor 668015804 1 Overload, Compressor 668015805 1 Overload, Compressor 668015802 1 Overload, Compressor 668015806 1 Overload, Compressor 668015805 1 N/S Plate, Compressor 668793402 1 1 1 Plate, Compressor 668793401 1 1 1 1 1 1 71 Condenser- Coax Copper Inner Tube 073394501 1 1 1 Condenser- Coax Copper Inner Tube 073394601 1 1 1 Condenser- Coax Copper Inner Tube 668803301 1 1 1 Condenser- Coax CUNI Inner Tube 073394502 1 1 1 Condenser- Coax CUNI Inner Tube 073394602 1 1 1 Condenser- Coax CUNI Inner Tube 668803302 1 1 1 92 Evaporator Coil until 02/10 668959020 1 1 1 1 1 1 Evaporator Coil 02/10 & later 668959023 1 1 1 1 1 1 Evaporator Coil, LH until 02/10 668959022 1 1 1 Evaporator Coil, LH 02/10 to 10/14 668959024 1 1 1 Evaporator Coil, LH 10/14 & later 668959034 1 1 1 Evaporator Coil, RH until 02/10 668959017 1 1 1 Evaporator Coil, RH 02/10 to 10/14 668959025 1 1 1 Evaporator Coil, RH 10/14 & later 668959037 1 1 1 N/S= Not Shown. 208/230/60/1 208/230/60/1 1 208/230/60/1 Continued on next page. WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 10

Refrigeration Circuit Compressor, Condenser, Evaporator, Switch & Valves Components, Continued Unit Size 007 009 012 Ref Part Part No. Description Number 110 Reversing Valve until 3/11 106694110 1 1 1 1 1 1 Reversing Valve 3/11 to 11/17 910110425 1 1 1 1 1 1 Reversing Valve 11/17 & later 910198407 1 1 1 1 1 1 Reversing Valve until 3/11 106694111 1 1 1 Reversing Valve 3/11 to 5/14 910110426 1 1 1 Reversing Valve 5/14 & later 910124938 1 1 1 N/S Solenoid-Reversing Valve until 3/11 106694207 1 1 1 1 1 1 1 1 1 Solenoid-Reversing Valve 3/11 to 5/14 910110439 1 1 1 1 1 1 1 1 1 Solenoid-Reversing Valve 5/14 to 11/17 106694207 1 1 1 1 1 1 Solenoid-Reversing Valve 11/17 & later 910198415 1 1 1 1 1 1 Solenoid-Reversing Valve 5/14 & later 106694207 1 1 1 137 High Pressure Switch until 7/11 668803601 1 1 1 1 1 1 1 1 1 High Pressure Switch 7/11 to 03/16 910117560 1 1 1 1 1 1 1 1 1 High Pressure Switch 03/16 & later 910171269 1 1 1 1 1 1 1 1 1 151A Seat, Fitting.375 668188801 2 2 2 2 2 2 2 2 2 151B Core, Valve 668188701 2 2 2 2 2 2 2 2 2 151C Cap, Valve 668189501 2 2 2 2 2 2 2 2 2 160 Fusible Plug Assy 850008345 1 1 1 1 1 1 1 1 1 Plug Only 283 F 106057401 1 1 1 1 1 1 1 1 1 400 Valve, Expansion- 1/2 Ton 106489115 1 1 1 Valve, Expansion- 3/4 Ton 106489116 1 1 1 Valve, Expansion- 1 Ton 668803901 1 1 1 840 Line Weight 060746901 4 4 4 4 4 4 Line Weight 060746901 3 3 3 842 Line Weight 067009101 1 1 1 N/S Electric Heater- 2.5KW C14= 2 667994907 1 1 1 1 1 1 1 1 1 N/S= Not Shown. 208/230/60/1 208/230/60/1 1 208/230/60/1 WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 11

Control Box MicroTech III Controls Components 120 190 080 120 190 080 250 100 250 200 100 208-230V Units 265V Units 007 009 012 Ref. No. Part Description Part Number 208-230/60/1 208-230/60/1 208-230/60/1 N/S Bracket, Capacitor 850010570 1 1 1 1 1 1 1 1 1 N/S Capacitor, Compressor, 50MFD 440V (until 04/12) 067291519 1 Capacitor, Compressor, 50MFD 440V (04/12 & later) 910120053 1 Capacitor, Compressor, 20MFD 440V (until 04/12) 067291510 1 Capacitor, Compressor, 20MFD 440V (until 04/12) 067291511 1 1 1 Capacitor, Compressor, 20MFD 440V (04/12 & later) 910120047 1 1 1 1 Capacitor, Compressor, 55MFD 440V (until 04/12) 067291522 1 1 1 Capacitor, Compressor, 55MFD 440V (04/12 & later) 910120054 1 1 Capacitor, Compressor, 25MFD 440V (until 04/12) 669450001 1 Capacitor, Compressor, 25MFD 440V (04/12 & later) 910120048 1 Capacitor, Compressor, 30MFD 440V (until 04/12) 067291518 1 Capacitor, Compressor, 30MFD 440V (04/12 & later) 910120049 1 080 Main Controller, MicroTech III 668105601* 1 1 1 1 1 1 1 1 1 N/S I/O Expansion Board Assy (until 08/12) 668105701* 1 1 1 1 1 1 1 1 1 I/O Expansion Board Assy (08/12 & later) 668105702* 1 1 1 1 1 1 1 1 1 100 LED Annunciator Assy 668395201 1 1 1 1 1 1 1 1 1 N/S Stand Off- PC Board 668803201 6 6 6 6 6 6 6 6 6 Stand Off- Comm. Card 802028115 4 4 4 4 4 4 4 4 4 190 Relay, Fan, 24V, 3PDT 802005906 1 1 1 1 1 1 1 1 1 N/S= Not shown on diagram. * When ordering this board, please provide the software part number printed on the board s label. See photo on Control Board Label Locations page. Continued on next page. WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 12

Control Box MicroTech III Controls Components, Continued 007 009 012 Ref. No. Part Description Part Number 208-230/60/1 208-230/60/1 208-230/60/1 200 Relay, 24V, 30A (until 04/13) 106500101 2 2 2 Relay, 24V, 30A (04/13 & later) 106500102 2 2 2 250 Transformer, 50VA (until 04/11) 060630802 1 1 1 Transformer, 50VA (04/11 & later) 910116204 1 1 1 Transformer, 50VA (until 04/11) 060614102 1 1 1 Transformer, 50VA (04/11 & later) 910116202 1 1 1 Transformer, 50VA (until 04/11) 060630702 1 1 1 Transformer, 50VA (04/11 & later) 910116203 1 1 1 Transformer, 75VA (until 04/11) 669529501 1 1 1 Transformer, 75VA (04/11 & later) 910117810 1 1 1 Transformer, 75VA (until 04/11) 667715902 1 1 1 Transformer, 75VA (04/11 & later) 910116213 1 1 1 Transformer, 75VA (until 04/11) 667715901 1 1 1 Transformer, 75VA (04/11 & later) 910116209 1 1 1 N/S Rocker Switch 061321501 1 1 1 1 1 1 1 1 1 N/S Switch, Momentary, N.O. 061377201 1 1 1 1 1 1 1 1 1 TStat Retrofit Kit, 7-Day Programmable, Unit Mnt 910104352 1 1 1 1 1 1 1 1 1 LUI Keypad Thermostat Programmable 668811001 1 1 1 1 1 1 1 1 1 Thermistor 669529401 1 1 1 1 1 1 1 1 1 N/S TStat Retrofit Kit, Non-Programmable, Unit Mnt 910104353 1 1 1 1 1 1 1 1 1 LUI Keypad Thermostat Programmable 668811001 1 1 1 1 1 1 1 1 1 Thermistor 669529401 1 1 1 1 1 1 1 1 1 N/S Control Temperature, Low Limit, +48 /+54 F 669521101 1 1 1 1 1 1 1 1 1 Control Temperature, Low Limit, +28 /+38 F 066540601 1 1 1 1 1 1 1 1 1 N/S Suction Line Temp (SLT) 910121227 1 1 1 1 1 1 1 1 1 N/S Air Temp Sensor (DAT) 107201601 1 1 1 1 1 1 1 1 1 N/S Water Temp Sensor (LWT) 107201601 1 1 1 1 1 1 1 1 1 N/S= Not shown on diagram. WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 13

Control Box MicroTech III Controls MTIII Control Board Label Locations Label Label 668105701 668105901 Label Label 668105601 668105801 NOTE: When ordering the control board, please provide the software part number printed on the board s label. See above for label locations. WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 14

Field Installed Accessories Filters Description 12 pack Part Number Filter- 9.75 X 29.25 High Sill Units 668816001 669521301 Filter- 8.75 X 23.75 Low Sill Units 668816101 669521303 Ball Valves, Motorized Valves & Relays Description Part Number Ball Valve, 1/2 (Box of 2) 106065102 Ball Valve, 1/2 (Box of 10) 106065110 Motorized Valve Kit 1/2 2-Way Valve, Normally Closed (NC), 25 PSi Close-Off Pressure 668996001 Motorized Valve Kit 1/2 2-Way Valve, Normally Closed (NC), 30 PSi Close-Off Pressure 668996003 Motorized Valve Kit 1/2 2-Way Valve, Normally Open (NO), 25 PSi Close-Off Pressure 668996002 MicroTech III, H-8 Output Wire Harness Assy 910107989 MicroTech III to Mark IV Daisy Chain Adaptation for E and U 910151282 Thermostats & Sensors Description Part Number Remote ENF Temp Sensor for 668375301, 668375401 107096010 Wall, Stat- AC/DC, ACO, 7 Day Programmable, 2 Heat/2 Cool with Wall Plate 668375301 Wall, Stat- AC/DC, ACO, Non-Programmable, 2 Heat/2 Cool, NSB & OR with Wall Plate 668375401 Wall Sensor for 910121746 & 910121748 667720401 Wireless Thermostats Description Part Number TStat, Wireless, 7 Day Programmable, Hi/Low Fan Speed 668898001 TStat, Wireless, Non-Programmable, Hi/Low Fan Speed 668898101 Field Programming Transfer Cable Description Part Number Field Programming Transfer Cable 669917901 MicroTech III Communication Modules Description Part Number LonWorks Comm Module 107293070 BacNet Comm Module 107293071 * Kit includes comm module card, sensors, mounting tabs, and IM. Continued on next page. WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 15

Field Installed Accessories Continued Hoses Description Specification Part Number Hose Assy, Fire Rated Condensate 3/4" NPT X 2' 106063801 3/4" NPT X 3' 106063901 Hose Assy, Fire Rated Supply/Return 1/2" NPT X 9 668817701 1/2" NPT X 12 668817702 1/2 NPT X 18 668817703 1/2 NPT X 24 668817704 Hose Assy, Plastic Condensate 3/4" NPT X 30" 106063701 3/4" NPT X 36" 106665101 Outdoor Air Dampers for High Sill Units* Description Part Number Manual O.A. Damper Kit 668816601 Motorized O.A. Damper Kit, 24V 910124326 * See IM 974-1. Subbase Kit Description Right Hand Left hand 3.5 Hi-Sill 910111373 910111372 7.0 Hi-Sill 106796202 106796201 1.0 Low-Sill 910111376 910111376 Straight Adapter & Elbow Kits Description Part Number 90 Elbow Kit 2 Pack 106066402 90 Elbow Kit 10 Pack 106066410 90 Elbow Kit 20 Pack 106066420 Elbow Only 061435301 Straight Adapter Kit 2 Pack 669522202 Straight Adapter Kit 10 Pack 669522210 Straight Adapter Kit 20 Pack 669522220 Adapter Only-.625 x.500 FPT 041116213 Fused Disconnect Kit Description Kit Fuse P/N Fuse, 265V, 7A 668817302 4EHG7750 Fuse, 265V, 10A 668817303 4EHG7795 Fuse, 208/230V, 7A 668817202 4EHG7750 Fuse, 208/230V, 10A 668817203 4EHG7795 Fuse, 115V, 15A 668817101 049128306 Fuse, 115V, 20A 668817102 049128307 Continued on next page. WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 16

Field Installed Accessories Continued MicroTech III Temperature Sensors Part Kit Tenant Set Point Status LED Fan & Number Override Adjustment Mode Switches 669088101 669529001 Yes No No No 668900801 669529101 Yes 55 to 95 F (12 to 35 C) Yes Yes 669088201 669529201 Yes -3 to +3 F (-1.5 to 1.5 C) No Yes Note: Can only be used in conjunction with a Communication (Comm.) card. See OM 931 for required jumper settings. Description Part Number ** Multiple Unit Control Panel: Allows a master unit controlled by a T'Stat, to operate up to 3 secondary units Not Recommeended for use with a Boilerless System Kit 056794201 Boilerless System Kit with I/O Expansion Board 910110355 Boilerless System Kit without I/O Expansion Board 910110353 ** Kit components listed below MicroTech III Unit Control Accessories Multiple Unit Control Panel Kit 310 311 313 Ref. Description Part Qty. No. Number 310 Cover- Control Box 106436101 1 311 Circuit Board 056794001 1 312 Stand Off- Circuit Board 802028090 6 313 Box 850007827 1 312 WSHP, WMHC/WMHW 007-012, Design 1 Rev. M 11/17 RPL 7000130 / Page 17

Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! Daikin Enfinity WSHP Console McQuay Enfinity WSHP Console WMHC, WMHW 007, 009, 012 Design 1 Critical Components Unit Sizes Voltage Part Number Control Control Board, MicroTech III ALL ALL 668105601 Compressor Compressor 007 668803001 Compressor 007 208-230/60/1 668803011 Compressor 007 668803021 Compressor 009 668951401 Compressor 009 208-230/60/1 668951411 Compressor 009 668951412 Compressor 012 668951504 Compressor 012 208-230/60/1 668951501 Compressor 012 668951503 Blower Fan Assy Motor ALL 667994201 Motor ALL 208-230/60/1 667994202 Motor ALL 667994203 Fan Housing & Wheel Fan Housing ALL N/A 668793803 Wheel, Tangential ALL N/A 667996502 Sensor Line Temp Sensor (SLTS) ALL N/A 910121227 Air Temp Sensor (DAT, RAT) ALL N/A 107201601 Water Temp Sensor (LWT) ALL N/A 107201601 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call 1-800-37PARTS 7000130 Rev. M 11/2017 CPL Page 1 of 1