REKO heat recovery units REKO HEAT RECOVERY UNITS TYPE A TYPE D

Similar documents
DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

Energy. The Energy ducted units have been designed. Heat Recovery Unit

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Series VENTS VUT R WH ЕС

Heating / Air Conditioning Energy Heat Recovery Units ENVIRONMENTAL COMFORT

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Blower-YEFB-020-3R-1maxVel

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

QZB "Standard" comfort fan coil

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

FAN COIL UNITS. The optimal solution for limited space

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

Series VUT PW EC. wool internal heat and sound-insulating layer for VUT PE/PW 350, 600, 1000 units and 50 mm for VUT PE/PW 200, 3000 units.

technical data Fan coil unit FWB small duct unit

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

GHE Dehumidifiers for radiant cooling systems with heat recovery

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Series. Suspended air supply units with the air capacity up to 4100 m 3 /h in the sound- and heat-insulated casing with the water heater

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

TEVHR. Heat Recovery Ventilator

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

Fan Coil Range HYDRONIC TERMINALS

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CFI VERTICAL WATER RECESSED DUCTABLE TERMINAL UNIT

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

The Sabiana. of Fan Coil

CLIMACIAT AIR COMPACT

EHH SERIES DRAW THROUGH FAN COILS CFM

Type PWX HORIZONTAL CHASSIS TYPE WATERSIDE FANCOILS FOR CONCEALED OR EXPOSED INSTALLATIONS

Technical Data Ducted Three Phase Split System Air Conditioner

MRXBOXAB-ECO-LP1 100% Typical Installation. (including opposite handed versions)

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

next p dw next p dw rcgroupairconditioning

TopVent Design Handbook

39HX. High-efficiency dual-flow air handling unit PRODUCT SELECTION DATA. Plug & play unit (built-in control) Class A+ across entire range

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

EHW KH PF HIGH EFFICIENTY AIR CONDITONING UNITS TECHNICAL CATALOGUE

CONFIGURABLE CROSS-FLOW HEAT RECOVERY UNITS ENERGY-BOX HE

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: May-08 PRODUCT NEWS. Advanced Product News: Launching of New KPI-(502~2002)E1E & KPI-3002H1E units

IN LINE MIXED FLOW DUCT FANS AND ELECTRIC HEATER TD-MIXVENT HEATING System

HEAT RECOVERY UNITS TSEK. Mech-Elec, 41, Hawthorn Road, Western Ind. Est., Dublin 12 Tel:

NEW GREEN TECHNOLOGY

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

ENERGY RECOVERY VENTILATION (ERV)

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

next evo cw next evo cw rcgroupairconditioning

KOG LN. Low Noise Chilled Water Cassettes Models 30 & 45

Series VENTS MPA...W. Supply units with the air capacity up to 6500 m 3 /h in the compact sound- and heat-insulated casing with water heater

LOW STATIC HYDRONIC DUCTED UNIT

KITCHEN EXTRACTORS CK Series Plastic range CK-60 F CK-40 F CK-25 N

The World of. Standard and Special Air Handling Units for Ventilation and Air Conditioning Applications

Lo-Carbon Sentinel Kinetic Horizontal

YAH SERIES FAN COIL UNITS

Heat and energy recovery ventilators

Framework is anodised aluminium with airtight door seals and manual door catches which can be tool locked in position.

Dehumidification and ventilation for residential, industrial radiant systems and swimming pools

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

PRODUCT RANGE: ROOFTOP PACKAGE

48 50 UH UA PACKAGED ROOFTOP

Technical Manual. New Water Cassette. Series BREZZA DOUBLE

VERSO Air Handling Units

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.


GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

BRIZA_038. EC MOTOR Briza Hybrid: High performance technology

EEDEN technical data. Fan coil units FWV-FWL-FWM FWD FWB FWC FWF FWT

CAW Ceiling-mounted fan heaters for hot water

Centrifugal air heaters hot water or electrical supply

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

The technical and dimensional data reported in this manual may be modified in view of any product improvement.

HEATING & COOLING COIL PRODUCTS

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Direct Fired Heater Model AD Specification

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

ROOFMASTER STEF-HT ROOF FAN

NEXT DL NEXT DL. rcgroupairconditioning

Transcription:

REKO HEAT RECOVERY UNITS The heat recovery units making up the series REKO have been designed and built to solve the problems tied to the high energy consumption of systems that use outdoor air. A high-efficiency heat exchanger makes it possible to recover up to 50% of the thermal energy that would otherwise be expelled into the atmosphere as exhaust. Available in 7 different sizes with a nominal air flow rate ranging from 600 to 4000 m 3 /h, reko heat recuperators complete traditional systems comprising fan coil units and air-conditioning units which work both in summer and winter. The reko units are especially suitable for false-ceiling installation and can be ducted to allow air to be drawn from and discharged directly into the room. BEARING STRUCTURE Reko units have a structure built from ALUZINK, with single or dual panelling with polyethylene and polyester heat and sound insulation, thickness 10mm for sizes 06-10 and 20 mm for sizes 14-19 -25-30 and 40. The panels are secured to the structure with cadmium-plated steel screws. All internal components are accessible for inspection and may be very easily removed from below if necessary. FAN MOTORS The fan-drive assemblies comprise a dual suction fan with forward-curving blades mounted on vibration-damping supports. They are sized in order to work at maximum speed while generating as little noise as possible. The electric motor is a single-phase 230 V - 50 Hz motor with one or more speeds that may be adjusted from the control panel. It is directly coupled with the fan. HEAT EXCHANGER The plate heat exchanger is of the cross-flow static type and can guarantee a high yield in all operating conditions. The plates are made of aluminium and the flows are separated by special seals. A stainless steel drip tray with a circular drain pipe is situated beneath the heat exchanger. AIR FILTER The filters have flat cells with a corrugated partition; they can be removed from below and are washable, with class G3 synthetic fibre filtering media (efficiency 85% by weight). BAP REP CDE TDV SAF TEG TATM ACCESSORIES hot water coil electrical heating element wall-mounted speed switch wall-mounted control panel complete with thermostat chilled water coil anti-freeze thermostat Covering panels for outdoor unstallation CONFIGURATION Available in stock in the A configuration, the position of air suction and for both fresh and indoor air can be adjusted during the installation job as shown in the pictures below Indoor air suction TYPE A TYPE B Indoor air suction Indoor air suction TYPE C TYPE D Indoor air suction VM66000070-00 78

Model 0 6 10 14 19 25 30 40 Air flow m 3 /h 600 1000 1400 1900 2500 3200 4000 Available static pressur Pa 80 90 140 120 110 170 170 Sound pressure db(a) 56 54 59,5 58 57,5 60 62 Axle power available W 2x90 2x147 2x350 2x350 2x350 2x550 2x750 Poles n 2 4 4 4 4 4 4 Maximum current absor A 1,8 3 5,8 6,2 6 11,4 6,2 Fan speeds n 1 3 3 3 3 3 2 Protection degree IP 54 44 55 44 55 20 55 Insulation class F F F F F F F Power supply V 230 230 230 230 230 230 400 Efficiency % 54,6 53,4 52,1 51,8 57,6 56 55,6 Heating capacity kw 2,6 4,6 6,2 8,4 12,3 15,3 19,4 Outlet air temperature C 8,7 8,3 8 7,9 9,4 9 8,9 Class G3 G3 G3 G3 G3 G3 G3 Frontal air speed m/s 3,6 2,9 4,1 4,5 3,8 4,3 4,3 300 356 356 363 528 528 528 Dimensions mm 178 293 293 353 373 413 513 48 48 48 48 48 48 48 The aforesaid performance is related to the following conditions - indoor air temperature = 20 C fresh air = -5 C - rated air flow REKO rated technical data FAN-MOTOR GROUP HEAT EXCHANGER FILTERS REKO - heat recovery units Code Model Air flow m3/h Available static pressure Pa heat exchanger efficiency % Price list ¼ REKO06 REKO 06 - Singer skin heat recovery unit 600 80 54,90 2.530,82 REKO10 REKO 10 - Singer skin heat recovery unit 1000 90 53,40 3.117,73 REKO14 REKO 14 - Singer skin heat recovery unit 1400 140 52,10 3.642,87 REKO19 REKO 19 - Singer skin heat recovery unit 1900 120 51,8 4.365,49 REKO25 REKO 25 - Singer skin heat recovery unit 2500 110 57,6 5.015,30 REKO30 REKO 30 - Singer skin heat recovery unit 3000 170 56 5.489,68 REKO40 REKO 40 - Singer skin heat recovery unit 4000 170 55,6 6.557,62 REKO06DP REKO 06 DP - Double skin heat recovery unit 600 80 54,90 2.765,81 REKO10DP REKO 10 DP - Double skin heat recovery unit 1000 90 53,40 3.330,66 REKO14DP REKO 14 DP - Double skin heat recovery unit 1400 140 52,10 3.931,92 REKO19DP REKO 19 DP - Double skin heat recovery unit 1900 120 51,80 4.721,83 REKO25DP REKO 25 DP - Double skin heat recovery unit 2500 110 57,6 5.489,68 REKO30DP REKO 30 DP - Double skin heat recovery unit 3000 170 56 5.927,67 REKO40DP REKO 40 DP - Double skin heat recovery unit 4000 170 55,6 6.908,44 79 VM66000070-00

Wall mounted control panel EYCDE CDE Wall mounted speed selector switch 26,41 EYTDV TDV Wall mounted control panel provided with fan speed selector, electromechanical thermostat, and cooling / heating mode selec 88,03 Post heating water coil (factory mounted) BAP10 Post heating water coil for REKO 10 435,78 BAP14 Post heating water coil for REKO 14 542,79 BAP19 Post heating water coil for REKO 19 646,50 BAP25 Post heating water coil for REKO 25 723,72 BAP30 Post heating water coil for REKO 30 728,14 BAP40 Post heating water coil for REKO 40 885,89 Post electric heater element (factory mounted) REP06 post electric heater for REKO 06, 230 V single-phase, 4 kw 732,54 REP10 post electric heater for REKO 10, 400 V three-phase 4,5 kw 909,06 REP14 post electric heater for REKO 14, 400 V three-phase6 kw 1.071,24 REP19 post electric heater for REKO 19, 400 V three-phase9 kw 1.247,75 REP25 post electric heater for REKO 25, 400 V three-phase12 kw 1.342,63 REP30 post electric heater for REKO 30, 400 V three-phase12 kw 1.342,63 REP40 post electric heater for REKO 40, 400 V three-phase12 kw 1.342,63 Chilled water coil module SAF10 Water coil post heating for REKO 10 747,99 SAF14 Water coil post heating for REKO 14 747,99 SAF19 Water coil post heating for REKO 19 885,89 SAF25 Water coil post heating for REKO 25 965,33 SAF30 Water coil post heating for REKO 30 1.096,62 SAF40 Water coil post heating for REKO 40 1.096,62 Anti-freeze thermostat TEG Anti-freeze thermostat REKO 218,44 Covering panels for outdoor installation TATM covering panels for outdoor installation REKO * 165,48 * price list at square meter VM66000070-00 80

81 VM66000070-00

vm66000070