Part Ⅰ : Technical Information

Similar documents
Thank you for selecting LENNOX air conditioners.

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Service Manual. Model: ACZEM4C4R18/ACZCI4C4R18 ACZEM4H4R18/ACZCI4H4R18 ACZEM4C4R24/ACZCI4C4R24 ACZEM4H4R24/ACZCI4H4R24 (Refrigerant:R410A)

Change for Life. Service Manual

Change for Life. Service Manual GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI

Change for Life. Service Manual. Models: MULTI18HP230V1BO MULTI24HP230V1BO GREE ELECTRIC APPLIANCES,INC.OF ZHUHAI

AIR CONDITIONING SYSTEMS WALL MOUNTED UNIT

Service Manual "X" SERIES 18K - 24K - 208/230V INVERTER-DRIVEN AIR CONDITIONING UNITS PLEASE READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS

Service Manual. Models WAH48115MB WAH412230MB WH48YMB WH412ZMB

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

GWH09QB-K3DNC6D GWH12QB-K3DNA1D GWH12QB-K3DNA2D GWH12QB-K3DNA3D GWH12QB-K3DNA6D GWH12QB-K3DNB2D GWH12QB-K3DNB4D GWH12QB-K3DNB6D GWH12QB-K3DNB8D

Specifications. (Model) KSIB009-H /2500 (W) 10600/9000(Btu/h) 13000/9500(Btu/h) 1250/ / SEER 16 HSPF 9.

DESHUMIDIFIER MH-V5 Service manual

Service Manual. Models WAH418230MB WH418ZMB WAH424230MB WH424ZMB

SERVICE MANUAL. Split Air Conditioner Arctic Series mod. A

Service Manual "P" SERIES 30K - 36K 220V INVERTER-DRIVEN AIR CONDITIONING UNITS IMPORTANT:

TECHNICAL GUIDE MODELS: DCMF/DHMF LX SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 16 SEER 1 PHASE 3/4 THRU 2 NOMINAL TONS DESCRIPTION

TECHNICAL GUIDE MODELS: INDOOR-DHPM/OUTDDOR-DHMF LX SERIES DUCTLESS MULTI-ZONE SPLIT HEAT PUMPS 16 SEER 1 PHASE 1.5 THRU 3.5 NOMINAL TONS DESCRIPTION

MAFX/GRFX DC INVERTER

TECHNICAL DATA & SERVICE MANUAL

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

The breaker trips at once when it is set to ON. The breaker trips in few minutes when it is set to ON.

AIR CONDITIONING SYSTEMS WALL MOUNTED UNIT

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Service Manual. MODEL: GWC09KF-K3DNA5A GWH09KF-K3DNA5A GWC12KF-K3DNA5A GWH12KF-K3DNA5A (Refrigerant R-410A) GREE ELECTRIC APPLIANCES,INC.

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

SERVICE MANUAL MXZ-2A40VA - MXZ-2A52VA - MXZ-3A54VA - MXZ-3A54VA - MXZ-4A71VA - MXZ-4A71VA - MXZ-4A80VA - E1 OUTDOOR UNIT. No. OB377 REVISED EDITION-A

Air Conditioner Service Manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

SERVICE MANUAL MXZ-A18WV - MXZ-A26WV - MXZ-A32WV - E1 HFC. Inverter-controlled multi system Models SPLIT-TYPE, HEAT PUMP AIR CONDITIONERS. No.

Service Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM


ROOFTOP PACKAGE (GC201105) TECHNICAL SALES GUIDE-50&60Hz CAPACITY RANGE:3~30TON SUPER HIGH AMBIENT OPERATION TO 55

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

SUBMITTAL M4MLW1809A-SUB-1A. Specifications 18 SERIES. Single Zone Mini-Split Inverter System M4MLW1809A1N0A M4TLS1809A11NA TAG:

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SERVICE MANUAL. Room Air Conditioner Split Wall-Mounted Type. Models:

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

ELECTRICAL QUANTITY WEIGHT (LB)

TECHNICAL DATA & SERVICE MANUAL

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL. Split Air Conditioner VERITAS INVERTER Series CH-S18FTXQ (WI-FI)

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

Product Data INDUSTRY LEADING FEATURES / BENEFITS

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

TECHNICAL DATA & SERVICE MANUAL

Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

HSP Ducted Series REFRIGERANT. SM HSP Ducted 1-A.1 GB DECEMBER Version:1

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

SPLIT TYPE AIR CONDITIONER WAS-09HSTD WINTAIR

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

MODELS INSTALLATION INSTRUCTIONS AND HOMEOWNER S MANUAL COND COND INSTALLER / SERVICE TECHNICIAN: HOMEOWNER: CAUTION

[U] Serie MOV. Manual de Ingeniería

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw)

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Use the information in this manual for the installation / servicing and keep the document near the furnace for future reference.

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

CENTRAL AIR CONDITIONERS SUPER FREE MATCH SERIES SERVICE MANUAL. T1/R410A/50Hz ( GC )

Service manual. MIV V4+ Mini

CAUTION ! WARNING SAFETY CONSIDERATIONS INTRODUCTION. 38MGR Multi-zone Outdoor Unit Ductless System Sizes 18, 24, 30, 36 and 48

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

TABLE OF CONTENTS ERSQ-AAY1

Artful Inverter. Introduction and Features. Model. Remarks

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

Troubleshooting & Reference

TABLE OF CONTENTS RMXS-E8V1B

Change for Life. Service Manual. Models: CH-S24FTXE Wi-Fi (Refrigerant R410A)

Cozy Hi Wall Inverter Air Conditioner

13 SEER CONDENSING UNITS & AIR HANDLERS

1. CF0.5E CF0.5M CF0.8E CF0.8M type

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

Service Manual & Installation Manual

Change for life. Service Manual GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

Wiring Diagrams Units Produced After April 20, 2009

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

R4H4. Product Specifications

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

1 Summary and features. Service Manual. Model QSVMI-09A QSVMI-12A QSVMI-18A

DC Inverter Multi-split System Technical Manual - 50Hz/R410a

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

Service Manual & Installation Manual

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Heat Pump Split Air Conditioner

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

Multi Inverter Air Conditioning Condensing Units - Summary

Transcription:

Part Ⅰ : Technical Information 1. Summary Outdoor Unit GWHD(6)KJO GWHD(4)KJO Technical Information 1

. Specifications Model GWHD(6)KJO GWHD(4)KJO Product Code C860W0190 C860W000 Rated Voltage V~ 0-40 0-40 Power Rated Frequency Hz 50 50 supply Phases 1 1 Cooling capacity(max~min) W 10000(600~10500) 11400(600~1000) Heating capacity(max~min) W 1100(600~1000) 1000(600~1000) Cooling Power Input W 000 500 Heating Power Input W 100 50 Cooling Current Input A 1.5 15 Heating Current Input A 1.5 14 Rated Power Input W 800 4000 Rated Current A 0 0 AEER W/W.0. ACOP W/W.58.65 Compressor Trademark ZHUHAI LADA ZHUHAI LADA COMPRESSOR CO.,LTD COMPRESSOR CO.,LTD Compressor Model QXAS-DzX090A QXAS-DzX090A Compressor Refrigerant Oil Type FV50S FV50S Compressor Type Inverter Rotary Inverter Rotary L.R.A A / / Compressor Rated Load Amp (RLA) A 15.6 17.8 Compressor Power Input W 4150 4150 Compressor Thermal Protector 1T11L-6 1T11L-6 Throttling Method Electron expansion valve Electron expansion valve Cooling Operation Ambient Temperature Range O C -7~48-7~48 Heating Operation Ambient Temperature Range O C -15~0-15~0 Condenser Material Aluminum Fin-copper Tube Aluminum Fin-copper Tube Condenser Pipe Diameter mm Φ7.94 Φ7.94 Rows-Fin Gap(mm) mm -1.4-1.4 Coil length (l) X height (H) X coil width (L) mm 1056X86X776 1056X86X776 Fan Motor Speed (rpm) (H/M/L) rpm 880 880 Output of Fan Motor W 140 140 Outdoor Fan Motor RLA A / / Unit Fan Motor Capacitor μf / / Air Flow Volume of Outdoor Unit m /h 7700 7700 Fan Type-Piece Axial-flow Axial-flow Fan Diameter mm Φ570 Φ570 Defrosting Method Automatic Defrosting Automatic Defrosting Climate Type T1 T1 Isolation I I Moisture Protection IP4 IP4 Permissible Excessive Operating Pressure for the Discharge Side MPa 4. 4. Permissible Excessive Operating Pressure for the Suction Side MPa.5.5 Dimension (WXHXD) mm 1087X110X440 1087X110X440 Dimension of Package (LXWXH) mm 1155X480X1115 1155X480X1115 Dimension of Package(LXWXH) mm 1158X48X110 1158X48X110 et Weight kg 89 90 Gross Weight kg 98 98 efrigerant Charge R410A R410A Refrigerant Charge kg.65.65 Technical Information

Cross-sectional Area of Power Cable Conductor mm 4.0 4.0 Recommended Power Cable(Core) Connection Pipe Connection Method - Flare Connection Flare Connection ot Additional Gas Connection Pipe Length m 40 40 Connection Pipe Gas Additional Charge g/m 0 0 Outer Diameter of Liquid Pipe(GREE Allocation) (Metric)1 mm Outer Diameter of Gas Pipe(GREE Allocation) (Metric)1 mm Φ9.5 Φ9.5 Outer Diameter of Liquid Pipe(GREE Allocation) (Metric) Outer Diameter of Gas Pipe(GREE Allocation) (Metric) Φ9.5 Φ9.5 Outer Diameter of Liquid Pipe(GREE Allocation) Outdoor (Metric) Unit Outer Diameter of Gas Pipe(GREE Allocation) (Metric) Φ9.5 Φ9.5 Outer Diameter of Liquid Pipe(GREE Allocation) (Metric)4 Outer Diameter of Gas Pipe(GREE Allocation) (Metric)4 Φ9.5 Φ9.5 Outer Diameter of Liquid Pipe(GREE Allocation) (Metric)5 Outer Diameter of Gas Pipe(GREE Allocation) (Metric)5 Φ9.5 Φ9.5 Connection Pipe Max. Height Distance(indoor and indoor) m 7.5 7.5 Max. equivalent connection pipe length(outdoor to last indoor) m 5 5 Connection Pipe Max. Length Distance(total lenght) m 75 75 The above data is subject to change without notice. Please refer to the nameplate of the unit. Technical Information

. Outline Dimension Diagram 1016 61 401 1106 1098 440 61 Unit:mm 4 Technical Information

4. Refrigerant System Diagram M Filter Four-way Valve Silencer Outdoor Unit High Pressure Swicth Compressor Electronic Expansion Valve Filter Stop Valve Indoor Unit Gas/Liqiud Separator Heating Cooling Schematic Diagram of Free Match Series Inverter Heat Pump System Technical Information 5

5. Electrical Part 5.1 Wiring Diagram Instruction Symbol Symbol Color Symbol Symbol Color Symbol ame WH White G GREE COMP Compressor YE Yellow Brown Grouding wire Red Blue YEG Yellow/Green BK Black VT Violet OG Orange Outdoor Unit (1)Model:GWHD(6)KJO POWER UIT A UIT B UIT C L UIT D XT L XTA XTB XTC XTD RJ45 COECTOR MODULE C804 θ 50K θ 0K θ 0Kθ 15K RT1A RT1B RT1C RT1D L6 L6 AC-L L5 L5 AP C80 L7 C1 4YV θ 0K θ 0K θ 0K θ 0K L4 L4 P1-1 GD1-1 BK YE WH AC-L GD1- P1-1 5 7 9 4WAY COMU C80 0K θ 0K θ θ 0Kθ 0K RTA RTB RTC RTD RTA RTB RTC RTD L8 HPP EV-A EV-B EV-C EV-D OVC-COMP OFA M LX1-1 LX1- LX-1 LX- E W V YE U EKV-A EKV-B EKV-C EKV-D YEG HP P SAT WH L OG L WH L OG L X1 L1 YE V U W YEG LA LB RTA-D RTA-D RT1B-C RT1D OUTLET PI TEMP. SESOR ILET PI TEMP. SESOR OUTDOOR TUBE SESOR OUTDOOR TEMP.SESOR RT1A DISCHARGE TEMP.SESOR XT/XTA-D WIRIG BOA L1-8 MAGET RIG LA- B REACTOR COMPRESSOR OVERLOAD SAT PROTECTIO COMP COMPRESSOR M FA MOTOR 4YV HP EKV A-D AP SYMBOL 4-WAY VALVE VOIL HIGH PRESSURE SWITCH ELECTROIC EXPASIO VALVE MAIBOA AME COMPOET POSITIO DIAGRAM XTA XTB XTC XTD XT SIGLE COECTIO BOA AP 6 Technical Information

()Model:GWHD(4)KJO POWER UIT A UIT B UIT D UIT C UIT E L MODULE XT L XTA XTB XTC XTE XTD C804 RJ45 COECTOR θ 50K θ 0K θ 0Kθ 15K RT1A RT1B RT1C RT1D L6 L6 AC-L L5 L5 AP C80 L7 C1 4YV L4 L4 θ 0K θ 0K θ 0K θ 0K θ 0K P1-1 GD1-1 BK YE WH OG AC-L GD1- P1- C80 0Kθ 0K θ θ 0Kθ 0K θ 0K RTA RTB RTC RTD RTE RTA RTB RTC RTD RTE 1 5 7 9 4WAY COMU HPP EV-A EV-B EV-C EV-D OVC-COMP L8 EV-E OFA M LX1-1 LX1- LX-1 LX- E W V YE U EKV-A EKV-B EKV-C EKV-D YEG HP P EKV-E SAT WH L OG L WH L OG L X1 L1 YE V U W YEG LA LB RTA-E RTA-E RT1B-C RT1D OUTLET PI TEMP. SESOR ILET PI TEMP. SESOR OUTDOOR TUBE SESOR OUTDOOR TEMP.SESOR RT1A DISCHARGE TEMP.SESOR XT/XTA-E WIRIG BOA L1-8 MAGET RIG LA- B REACTOR COMPRESSOR OVERLOAD SAT PROTECTIO COMP COMPRESSOR M FA MOTOR 4YV HP EKV A-E AP SYMBOL 4-WAY VALVE VOIL HIGH PRESSURE SWITCH ELECTROIC EXPASIO VALVE MAIBOA AME COMPOET POSITIO DIAGRAM XTA XTB XTC XTD XTE XT SIGLE COECTIO BOA AP These circuit diagrams are subject to change without notice, please refer to the one supplied with the unit. Technical Information 7

5. PCB Printed Diagram Top view 9 10 11 1 1 14 15 8 7 6 Bottom view 5 4 1 16 17 1 T5AH 50V: Fuse : terminals of neureal wire AC-L: terminals of line wire 4 PFC electrocircuit U/V/W: terminals of 5 compressor OVC-COMP: terminals of 6 overload protector HPP: terminals of high 7 pressure switch EVA-EVE: terminals of 8 EXV(electronic expansion valve) C80-C80: terminals of 9 temperature sensor 10 etwork wire of COMU: terminals of 11 communication 1 OFA: terminals of fan HEAT1: terminals of bottom 1 band heater HEAT: terminals of compressor 14 band heater 4WAY: terminals of 4-way 15 valve 16 K101: Main relay 17 L4-L5: choke 8 Technical Information

6. Function and Control 1. Function Control 1) Cooling mode a. Turning on the unit for cooling operation, and if any one of the indoor units satisfy the cooling operation condition, the system will start for cooling operation; and the electronic expansion valve, the outdoor fan and the compressor start operation. b. When some of the indoor units satisfy the stop-condition while some indoor units does not satisfy the stop-condition, the compressor does not stop, the compressor adjust the frequency according to demand. For the indoor unit with stop-condition satisfies, the corresponding electronic expansion valve will be closed. c. Change Cooling mode to heating mode When change the unit to heating mode from cooling mode, the whole system will stop first. Then the system will restart in heating mode after the compressor stops. d. 4-way valve In this mode, the 4-way valve is closed. e. Outdoor fan control in cooling mode The outdoor fan starts before 5s of the starting of compressor. The outdoor fan will run in high speed after starting and then it will run in set speed. ) Dry mode (dehumidification mode) this mode is the same as cooling mode; ) Heating mode a. Turning on the unit for heating operation, If any one of the indoor unit satisfy the heating condition, the system will start to run in heating mode b. If all the indoor units satisfy the stop-condition, the compressor stops and the outdoor fan stops after 1min; c. If only part of the indoor units satisfy the stop-condition, the compressor decrease the frequency immediately and operates according to demand. d. Change Heating mode to cooling mode or dehumidification mode, the whole system will stop first, then restart under the required mode. e. Defrosting function When the defrosting condition is satisfied, the 4-way valve reverses the direction, the outdoor fan stop.after the 4-way valve reverses the direction, the frequency of compressor rises, and the unit will start defrosting under cooling cycle. 4) Fan mode Only indoor fan run. Compressor, outdoor fan and 4-way valve are closed.. Protection Function 1) Mode conflict protection of indoor units When the setting mode is different of different indoor unit, the unit runs in below status: a. The system mode is determined by the first turning on indoor unit except indoor unit is in fan mode. Cooling mode (dry mode) is in conflict with heating mode. b. If the first turning on unit is fan mode, and the second turning on unit is cooling or heating mode, then the system will run in cooling or heating mode ) Overload protection If the tube temperature at the high pressure side is higher than normal, the compressor frequency is restricted or decreased to normal operation frequency. ) High exhaust temperature protection If the exhaust temperature is higher than protection value, the compressor stops running. If the exhaust temperature protection continuously appears for 6 times, the compressor can t resume running. In this case, only by cutting off the power and then reenergize that the compressor can restart. If the running duration of the compressor is longer than 10min, the protection times will be cleared to zero time. 4) Communication malfunction Detection of the quantity of installed indoor units: after min of energizing, if the outdoor unit does not receive the communication data of certain indoor unit, the outdoor unit will judge that indoor unit is not installed. If the outdoor unit receives the communication data of that indoor unit later, the communication malfunction will be cleared. Technical Information 9

5) System high-pressure protection a. When the high-pressure switch detects the system pressure higher than limit,then the high-pressure switch cuts off, the system will stop to run. b.if high-pressure protection is detected for two times within one hour, only by cutting off the power and then reenergize that the compressor can restart. 6) Compressor overload protection o matter the compressor is on or off, when the compressor overload switch is detected activated, the system will stop and indoor unit will display H. If the compressor overload protection appears for more than 6 times, in this case, only by cutting off the power and then reenergize that the compressor can restart. If the running duration of the compressor is longer than 0min, the protection times will be cleared to zero. 7) Antifreeze protection Under cooling and dry mode, 6minutes after the compressor is started: When it is detected for minutes successively that Tevap. Is less than - O C(varying with indoor unit), the antifreeze protection will be activated, in which case the outdoor unit will immediately shut off the indoor electronic expansion valve and the capacity will be set to 0. If Tevap. exceed 1 O C and the compressor has remained at OFF for at least minutes, the compressor will resume its original operation state. 8) IPM Protection a. When the IPM module protection is detected, the unit will stop as the indoor temperature reaching set temperature, PFC is closed, display IPM protection malfunction. After the compressor stops for min, the unit will resume operation status automatically; if the IPM protection is detected for more than 6 times continuously (If the running time of the compressor is longer than 10min, the protection times record will be cleared), the system will stop and send the signal of module protection to indoor unit. The unit can not resume operation status automatically, but can resume running only after cutting off the power and then putting through the power. b. IPM module overheating protection (a) When TIPM > 88 O C, prohibit to raise frequency; (b) When 88 O C < TIPM < 95 O C, the operation frequency of compressor lows down 1HZ/1s; (c) When TIPM > 100 O C, the compressor stops. After the compressor stops for min, if TIPM < 77 O C, the compressor and the outdoor fan will resume operation. 9) function If the power of device is supplied by switching power supply, when different signals are received, the corresponding optocouplers are put through to make the AD sample circuit on the main board detect the different voltages. Different voltages are corresponding to different modes. After entering mode, the indoor unit displays the corresponding operation code of mode. d1: Outdoor compressor stops; d: The electricity consumption of complete unit in 0min is less than or equals to 50% of rated electricity consumption; d: The electricity consumption of complete unit in 0min is less than or equals to 75% of rated electricity consumption 10 Technical Information