Air Conditioner SVC MANUAL(Exploded View)

Similar documents
LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static)

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

Single Zone Air Conditioner SVC MANUAL (Exploded View)

Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View)

SVC Manual(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

Multi V Air Conditioner SVC MANUAL(Exploded View)

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

Digital Inverter 4 series 8 & 10HP

Room Air Conditioner SVC MANUAL(Exploded View)

AIR-CONDITIONER SERVICE MANUAL

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

SVC Manual(Exploded View)

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Room Air Conditioner SVC MANUAL(Exploded View)

[U] Serie MHB / MHA Manual de Ingeniería

TECHNICAL DATA & SERVICE MANUAL

DESIGN & TECHNICAL MANUAL

OUTSIDE AIR UNIT ENGINEERING MANUAL

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Highly Efficient,Powerful Heating and Cooling.

V8MS Mode Selection Box for VRA Heat Recovery - 60HZ

DESIGN & TECHNICAL MANUAL

Concealed ceiling unit with medium ESP

Heat Pump Air Conditioning Systems

Air Conditioners. Technical Data FBQ-C

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.

Air Conditioners. Technical Data RZQG-L

TECHNICAL DATA & SERVICE MANUAL

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

SINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU

SAMSUNG DVM Air Conditioner. Accessories. DVM PLUS III HP/HR North America for 60Hz

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

technical data air conditioning systems FHYCP-B7 4-way Blow Ceiling Mounted Cassette (950x950) Split Sky Air

technical data air conditioning systems Indoor Units FBQ-C7VEB

Samsung 360 Cassette, Single Zone, Split System

Multi V Air Conditioner SVC MANUAL(Exploded View)

technical data air conditioning systems FHYP-B Ceiling Suspended Unit Split Sky Air

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

CASSETTE type INVERTER MULTI AIR CONDITIONER. Models AUY12LBAB AUY14LBAB AOY18LMAK2

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

TECHNICAL DATA & SERVICE MANUAL

DESIGN & TECHNICAL MANUAL

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Engineering Data Book

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Ductless Split Systems Concealed Duct Heat Pumps

Market District Commons. Black Oak Engineering. Daikin Ductless Heat Pump Split Systems N/A N/A M001. Plans. Fujitsu ductless heat pump systems

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

SERVICE MANUAL AIR CONDITIONER SPLIT TYPE

Ductless Split Systems Wall-mounted, Multizone Heat Pump

Wall Mounted Split Systems

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

SINGLE Technical Data Book SINGLE Duct S for America (R410A, HP)

Learn more about Samsung air conditioner at:

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

Air to Air Heat Exchanger

Single-Zone Four-Way Ceiling-Cassette System Engineering Manual

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

A single answer for multiple zones.

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

Air Conditioner CONTENTS

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

SiUS RXYQ72, 96, 144, 168, 192MTJU R-410A Heat Pump 60Hz RXYQ72MTJU RXYQ96MTJU RXYQ144MTJU RXYQ168MTJU RXYQ192MTJU

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

ELECTRICAL QUANTITY WEIGHT (LB)

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

ROOFTOP PACKAGED AIR CONDITIONERS

SERVICE MANUAL MUZ-FE09NA MUZ-FE09NAH MUZ-FE12NA MUZ-FE12NA1 MUZ-FE12NAH MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-F.

FLOOR STANDING, CEILING SUSPENDED, AND CONVERTIBLE SURFACE MOUNTED INDOOR UNIT ENGINEERING MANUAL

TECHNICAL DATA & SERVICE MANUAL

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

CASSETTE type INVERTER MULTI AIR CONDITIONER

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL

Transcription:

Internal Use Only http://biz.lgservice.com Air Conditioner SVC MANUAL(Exploded View) Type : Ceiling Concealed Duct MODEL : AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.

1. Specification Indoor Power Supply Model Name AMNW24GBGA0 [LMHN240HV] AMNW36GBGA0 [LMHN360HV] V, Ø, Hz 208/230, 1, 60 220, 1, 60 208/230, 1, 60 220, 1, 60 Capacity Nominal kw Class 7.03 10.6 Nominal Btu/h Class 24,000 36,000 Casing Color - - - W x H x D mm 1182 298 450 1182 298 450 Dimensions Body W x H x D inch 46-17/32 x 11-23/32 x 17-23/32 46-17/32 x 11-23/32 x 17-23/32 Net Weight Body kg (lbs) 36 (79.4) 41 (90.4) Heat (Row x Column x Fins per inch) x No. - (2 x 12 x 21) x 1 (3 x 12 x 21) x 1 Exchanger Face Area m 2 (ft 2 ) 0.26 (2.77) x 1 0.26 (2.77) x 1 Type - Sirocco Fan Sirocco Fan H / M / L m 3 /min 19.5 / 17.5 / 15.0 32.0 / 27.0 / 20.0 Air Flow Rate H / M / L ft 3 /min 688 / 618 / 530 1130 / 953/ 706 (Standard Mode) External Static Fan Pressure mmaq(inaq) 4 (0.16) 4 (0.16) H / M / L m 3 /min 19.5 / 17.5 / 15.0 32.0 / 27.0 / 20.0 Air Flow Rate (High Mode H / M / L ft 3 /min 688 / 618 / 530 1130 / 953/ 706 - factory set) External Static Pressure mmaq(inaq) 10 (0.39) 10 (0.39) Type - BLDC BLDC Fan Motor Output W x No. 154 x 1 350 x 1 Running Current A 0.9 1.4 Sound Pressure Level (Standard Mode) H / M / L db(a) 37 / 36 / 35 44 / 42 / 40 Sound Power Level Cooling db(a) - - Liquid mm(inch) 6.35 (1/4) 9.52 (3/8) Piping Connections Gas mm(inch) 12.7 (1/2) 15.88 (5/8) Drain (O.D / I.D.) mm(inch) Ø 32.0(1-1/4) / 25.0(31/32) Ø 32.0(1-1/4) / 25.0(31/32) Safety Devices - Fuse Fuse - Thermal Protector for Fan Motor Thermal Protector for Fan Motor Power and Communication Cable (included Earth) No. x AWG 4C x 18 4C x 18 Note: 1. All data are based on the following conditions: - Cooling Temperature : Indoor 26.7 (80 ) DB / 19.4 (67 ) WB Outdoor 35 (95 ) DB / 23.9 (75 ) WB - Heating Temperature : Indoor 21.1 (70 ) DB / 15.6 (60 ) WB Outdoor 8.33 (47 ) DB / 6.11 (43 ) WB - Piping Length : Interconnected Pipe Length = 7.5m - Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero. 2. Wiring cable size must comply with the applicable local and national code. 3. Due to our policy of innovation some specifications may be changed without notification. 4. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased owing to ambient conditions during operation. - 2 -

2. Piping Diagrams Heating Heat exchanger Gas pipe connection port (flare connection) Cooling Sirocco Fan M Thermistor for evaporator outlet temperature Thermistor for suction air temperature Thermistor for evaporator inlet temperature Liquid pipe connection port (flare connection) Description Thermistor for suction air temperature Thermistor for evaporator inlet temperature Thermistor for evaporator outlet temperature PCB Connector CN-ROOM CN-PIPE / IN CN-PIPE / OUT n Refrigerant pipe connection port diameters [Unit:mm(inch)] Model Gas Liquid AMNW24GBGA0 [LMHN240HV] Ø12.7 (1/2) Ø6.35 (1/4) AMNW36GBGA0 [LMHN360HV] Ø15.88 (5/8) Ø9.52 (3/8) - 3 -

3. Wiring Diagrams MODEL : AMNW24GBGA0 [LMHN240HV] CN-MOTOR1 CN-ZONE CN-FLOAT CN-EXT CN-DISPLAY CN-CC CN-POWER CN-D/PUMP CN-ROOM CN-PIPE/IN CN-REMO CN-PIPE/OUT - 4 -

MODEL : AMNW36GBGA0 [LMHN360HV] CN-MOTOR1 CN-ZONE CN-FLOAT CN-EXT CN-DISPLAY CN-CC CN-POWER CN-D/PUMP CN-VM CN-ROOM CN-PIPE/IN CN-REMO CN-PIPE/OUT CN-MOTOR1(IN) CN-MOTOR1 CN-VM_IN(BK) - 5 -

TEMP FAN SPEED OPER MODE 4. Exploded View MODEL : AMNW24GBGA0 [LMHN240HV] 349480 359012A 336600B 346810 348601 137213B 336600A 359012B 137214 349480 349600 147901 137213A Eva-In 263230B W51620 Eva-Out 263230C W3001 W50011 354210 268711E 263230A Air-Inlet W6640 268711A 135500 437213A 249951 267110 437213B 352114 352118 152302 330871 Location No. Description Sensor Information Housing Color 263230A Thermistor1(CN_ROOM) Air-Inlet Orange 263230B Thermistor2(CN_PIPE/IN) Eva-in White 263230C Thermistor3(CN_PIPE/OUT) Eva-out Red - 6 -

TEMP FAN SPEED OPER MODE MODEL : AMNW36GBGA0 [LMHN360HV] 349480 359012A 336600B 346810 348601 137213B 336600A 359012B 137214 349480 349600 147901 137213A Eva-In 263230B Eva-Out 263230C W3001 W50011 354210 268711E 263230A Air-Inlet W6640 268711A 268711B 135500 437213A 249951 267110 437213B 352114 352118 152302 330871 Location No. Description Sensor Information Housing Color 263230A Thermistor1(CN_ROOM) Air-Inlet Orange 263230B Thermistor2(CN_PIPE/IN) Eva-in White 263230C Thermistor3(CN_PIPE/OUT) Eva-out Red - 7 -

P/NO : MFL67523120 October, 2013