Vaporgard LED Series Leading the way in LED technology for industrial and hazardous applications 25W W LED REPLACES INCANDESCENT

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

V2LCHF2UNV1 Led Lumnr. Features. Material, Color, and Finish. Long Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

LED lighting for land-based rigs Pauluhn DLL LED Luminaires. Pauluhn DLL. LED luminaires for land-based drilling

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

An Eaton Intelligent Power solution. Champ VMV Connected lighting for hazardous areas

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

HID lighting for hazardous areas Champ HID floodlighting. Champ floodlights. HID floodlighting for hazardous areas

EVLPF Series Compact Fluorescent

N2MVF Series Compact Fluorescent

Applications. Standard Materials

LMV Series W Low Profile - Medium Base

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

VAPORGARD Incandescent Luminaires

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

SIMPLIFIED LIGHTING. TRUSTED PROTECTION. CODE MASTER LED LUMINAIRES CLASS I, DIVISION 1

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

DMV Series W For Combustible Dusts

UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

UTILITY LIGHT INTRODUCTION

Crouse-Hinds Enclosures. High performance, high reliability enclosures for global applications

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

50W Explosion Proof LED Light - C1D2, C2D1 - Replacement for 150W Metal Halide - Globe/Guard

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

150W Explosion Proof LED Flood Light - Surface Mount Lumens - C1D V AC

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Table 500-3(d) Identification Numbers. Maximum Identification

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

PRODUCT DATA SHEET LIGHTING PRODUCTS

Champ-Pak TM Wall Pack & Floodlight Luminaires Hazardous and Non-Hazardous

SafeSite LED Area Light - IECEx / ATEX for Indoor and Outdoor Hazardous Areas. Patent Pending

SafeSite LED Area Light - ATEX / IECEx. for Indoor and Outdoor Industrial Applications

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

Champ-Pak Wall Pack Luminares

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

DuroSite LED End-to-End Linear Fixture - UL / CSA for Indoor and Outdoor Industrial Applications

LED FIXTURE CATALOG. Shining light into the future

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

DuroSite LED High Bay - UL for Indoor and Outdoor Industrial Applications. Patent Pending

Rating. Class I Div II

BAS SFP22 Edge-lit LED Panel

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

COMPACT SIZE INTRODUCTION & LOGIC

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

MERCMASTER LED SERIES

High bay LED lighting fixture

300W EXP LED Light - 35,000 Lm - 3' Cart Mount - Quick Change Mount - C1D1-100' 16/3 SOOW- EXP Plug

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

Basics Series Surface Mount LED Fixtures. Affordable and easy-to-install, 4" and 6" fixtures. It s a. Snap

LHB LED High Bay. Technical Specifications. Description. Performance Data. Dimensions & Weights. Delivered Lumens Efficacy.

EVL-B - Zone 1, 2, 21, 22 - Replaces traditional discharge lamps more than 400W - Saves in energy, maintenance and installation

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

LED RETROFIT SOLUTIONS

DuroSite LED RTO Area Light - UL / CSA. for Indoor and Outdoor Industrial Applications #

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

Lighting Solutions. from a Leader in Light Source Technology

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

REDUCED PROFILE INTRODUCTION

Lighting Solutions from a Leader in Light Source Technology

DuroSite Series LED High Bay - UL for Indoor and Outdoor Industrial Applications. Patent Pending

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

SECTION INTERIOR LIGHTING

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

SDL4 LED Strip Diffused Lens

DuroSite TM LED High Bay. for Industrial & Commercial Applications.

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

BAS SDL8' LED Strip Diffused Lens

Dimensions (111mm) 3 (76mm) (111mm) (48mm)

Evolve LED Garage Light

Explosion Proof LED String Lights - 5 Hand Lamps - Class 1 & Class 2

Dimensions (111mm) (111mm) 3 (76mm)

LED LUMINAIRE SERIES LED Luminaire Series Improves Your Illumination Systems

HL-2449_flg:8 pager 6/17/10 11:19 AM Page 1 Tear Drop LED Series

120W Explosion Proof Signal Light w/ Audible Alarm - C1D1 - (2) Colored LED Lamps - 55 Horn Tones

Suite: Foyer/Hallway/Closet PROJECT: ZIGG CONDOS TYPES ' S1 ' & ' S6 ' Description: Flush Mount lass. Finish: Diameter: " Height: 4" Lamp: x

Transcription:

Hazardous area LED lighting Vaporgard LED Luminaires Vaporgard LED Low profi le incandescent replacement

Vaporgard Series LED Lighting Safe. Reliable. Efficient. Eaton's Crouse-Hinds offers the broadest portfolio of LED luminaires for any industrial or hazardous application. We utilize more than 100 years of lighting expertise to maximize the benefits of LED technology and provide the safest, most reliable LED luminaires on the market today. Application Challenge: You're faced with high energy and maintenance costs related to your current incandescent lighting fixtures. In addition, you re worried about upcoming legislation to ban incandescent lighting fixtures in your jurisdiction. You need a solution which will not only reduce operating expenses, but also replace your current incandescent fixtures prior to government regulations going into effect. Old way: Replace your current incandescent fixtures with a higher wattage luminaire that falls outside of the power range of the pending government regulations on incandescent lamps. Light output has increased, however, energy costs have gone up 30%, maintenance costs are still an issue, and future regulations may require another change. New way: Install Vaporgard LED Luminaires to realize an 85% reduction in energy consumption and slash maintenance costs associated with lamp replacement. The Vaporgard LED is designed to easily adapt to existing mounting modules for ease of installation. That, along with a 20 times longer life, makes Vaporgard LED an ideal replacement for incandescent light sources. Benefit: Realize $50K per year in energy and maintenance savings by installing Vaporgard. Qualify for rebate incentives with local municipalities and federal programs. Take advantage of the robust, low profile design by installing in those tough to get to locations. Why LED? Useful Life Rated life is up to 60,000 hours of maintenance-free and safe operation Energy efficiency LED average energy consumption is 85% less than incandescent Start/restart time Instant illumination compared to 10 minute restrike time for HID Light quality Higher color rendering and color temperature Environmental benefits LED reduces carbon footprint Mercury-free Why Crouse-Hinds? Industry-best reliability Built to withstand extreme temperatures, vibration, water and dust Thermal management Effective heat sinking ensures longer life Retrofit compatibility LED fixtures are compatible with Crouse- Hinds' incandescent installed base Why Vaporgard LED? 20X the life of incandescent lamps 50% lower profile than incandescent luminaires 2

Design features EASY INSTALLATION AND REPLACEMENT Contractor-friendly design is ideal for both retrofit and new construction application Installed using the same wall and ceiling mounts as incandescent Vaporgard fixtures RUGGED HEAT SINK Heat sink designed to perform in high ambient temperatures up to +55 C and as low as -30 C Thick walled castings make for a tough, rugged housing that keeps the internal driver and LED temperature down LOW PROFILE DESIGN Unique domeless, low profile design for low mounting heights and confined spaces where incandescent and HID based luminaires are too large to fit in the mechanical envelope required MULTIPLE LENS OPTIONS Tempered clear glass lens standard Diffused glass lens and teflon coated lens options available MODULAR DESIGN Compact and modular design allows for easy component replacement and future upgrades 3

Features & benefits Vaporgard LED Luminaires V2LC - Cool white color temperature The V2LC Luminaire provides uniform crisp, white light and is suitable for lower mounting heights, confined spaces, tunnels or utility rooms. Using four high power, high brightness LED arrays, this fixture can deliver similar light levels to 150 watt incandescent. V2LW - Warm white color temperature The V2LW Luminaire provides similar benefits as the cool white version, but with a color rendering more consistent with a warm incandescent or HPS lamp source. V2LC V2LW Available with DC power supply For applications with DC power requirements such as solar, battery or UPS. The DC power supply is suitable for 12VDC through 24VDC. Model number Nominal lumens V2LC/UNV1 1,633 22 V2LW/UNV1 1,400 22 V2LC/DC1 1,633 22 V2LW/DC1 1,400 22 Wattage Equivalent incandescent luminaire 150-200W incandescent Typical energy savings/lifetime 85% energy savings and over 50,000 hours of continuous operation! Vaporgard LED benefits: Enhance safety and productivity Instant illumination and re-strike Cold temperature operation; no warm-up time Multi-die LED arrays improve reliability Lightweight, low profile and cool surface temperatures Driver with internal fusing for branch circuit protection Reduce operation and maintenance costs 22 watt LED system can save up to 85% in energy costs 50K hours rated life can provide >10 years of maintenance-free lighting No mercury or hazardous chemicals - eliminates disposal concerns Mounts to existing Vaporgard mounting modules Reliable performance in any environment Shock- and vibration-resistant Teflon coated lens (suffix S896) option for increased safety in food processing facilities Low starting temperature: -25ºC Operating ambient: -25ºC to 55ºC (high temperature option) Applications: Oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, platforms, loading docks, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present Locations requiring continuous and consistent light levels in extreme ambient temperatures Where extremely corrosive, wet, dusty, hot and/or cold conditions exist Type 4X, marine, wet locations and hose-down environments Confined space or low ceiling areas, such as tunnels, utility rooms, over doorways, entries, landings, etc. Areas requiring frequent on/off of lights Areas where maintenance is difficult or challenging Areas requiring shatter-protected products, such as food processing facilities Outdoor wall or ceiling mounted area illumination Low mounting heights Classified and hazardous locations 4

Specifications Certifications and compliances: Class I, Division 2, Groups A, B, C, D Class II, Division 1, Groups F, G UL844; UL1598; UL1598A CSA C22.2 No. 137 NEMA 4X IP66 RoHS Compliant II 3 G Ex na IIC T4 Gc (T4 at 55 C) II 3 D Ex tc IIIB T69 C Dc IP66 EN60079-0:2009, EN60079-15:2010, EN60079-31:2009 DesignLights Consortium approved for select models Standard materials: Body and mounting modules copper-free aluminum with Corro-free epoxy powder coat Lens bezel aluminum with anodized finish Lens heat- and impact-resistant glass Gaskets silicone External hardware stainless steel Electrical ratings: Voltage V2LC/UNV1 V2LW/UNV1 V2LC/DC1 V2LW/DC1 90-264VAC, 277VAC 90-264VAC, 277VAC 12-24VDC Input power (Watts) 22 22 22 22 12-24VDC Input current 0.23/0.10 0.23/0.10 2.1 / 1.0 2.1 / 1.0 Power factor >0.9 >0.9 N/A N/A THD (I) (%) <20% <20% N/A N/A Maintained lumens 1633 1400 1633 1400 Color temperature 5600K 3000K 5600K 3000K 5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Crouse-Hinds standard Terms and Conditions. Temperature ratings: Max. temp C Temp. rating* V2LC/UNV1 40 T5 V2LC/UNV1 S902 55 T4A V2LC/DC1 40 T5 NV2LC/UNV1 40 T4 NV2LC/UNV1 S902 55 T4 *Contact your local sales representative for warm white temperature ratings. Weights: Model number Lbs. kg. Pendant mount 5.7 2.59 Ceiling mount 6.8 3.08 Wall mount 7.9 3.58 Stanchion mount 6.5 2.95 LED driver: Constant current regulated power supply 90VAC-264VAC, 277VAC, 50/60 Hz Internal fusing Active power factor correction, >0.9 Low harmonic distortion, <20% Low in-rush current, <20 amps EMC compliant to 47CFR, Part 2, Part 15 12-24VDC option available LED system: (4) High brightness LED arrays Cool white (5600K), CRI 65 Warm white (3000K), CRI 82 70% lumen maintenance (L70) at 50K hours Array complies with requirements of LM80 5

Ordering information NEC and CEC Cool white Warm white Mounting style AC drive DC drive AC drive DC drive ½ Pendant* V2LCA1/UNV1 V2LCA1/DC1 V2LWA1/UNV1 V2LWA1/DC1 ¾ Pendant* V2LCA2/UNV1 V2LCA2/DC1 V2LWA2/UNV1 V2LWA2/DC1 1 Pendant* V2LCA3/UNV1 V2LCA3/DC1 V2LWA3/UNV1 V2LWA3/DC1 ½ Wall with Junction Box V2LCHBF1/UNV1 V2LCHBF1/DC1 V2LWHBF1/UNV1 V2LWHBF1/DC1 ¾ Wall with Junction Box V2LCHBF2/UNV1 V2LCHBF2/DC1 V2LWHBF2/UNV1 V2LWHBF2/DC1 ½ Ceiling V2LCHF1/UNV1 V2LCHF1/DC1 V2LWHF1/UNV1 V2LWHF1/DC1 ¾ Ceiling V2LCHF2/UNV1 V2LCHF2/DC1 V2LWHF2/UNV1 V2LWHF2/DC1 ½ VXT Wall V2LCHT1/UNV1 V2LCHT1/DC1 V2LWHT1/UNV1 V2LWHT1/DC1 ¾ VXT Wall V2LCHT2/UNV1 V2LCHT2/DC1 V2LWHT2/UNV1 V2LWHT2/DC1 ½ VXW Wall* V2LCHW1/UNV1 V2LCHW1/DC1 V2LWHW1/UNV1 V2LWHW1/DC1 ¾ VXW Wall* V2LCHW2/UNV1 V2LCHW2/DC1 V2LWHW2/UNV1 V2LWHW2/DC1 1-¼ Stanchion* V2LCHJ4/UNV1 V2LCHJ4/DC1 V2LWHJ4/UNV1 V2LWHJ4/DC1 Adapter Only** V2LCHR/UNV1 V2LCHR/DC1 V2LWHR/UNV1 V2LWHR/DC1 *For use in Class I, Division 2 or Class II, Division 1, Groups F, G. For Class II, you must order complete catalog number (not available for purchase in components). **For use when wall mount or ceiling mount box is already installed. 5 year limited warranty. Refer to page 2 of the D-0413 authorized distributor price book for Crouse-Hinds standard Terms and Conditions. DesignLights Consortium approved models. Cool white only. IECEx/ATEX Dimensions Mounting style Cool white AC drive Warm white AC drive ½ Pendant NV2LCA1/UNV1 NV2LWA1/UNV1 ¾ Pendant NV2LCA2/UNV1 NV2LWA2/UNV1 1 Pendant NV2LCA3/UNV1 NV2LWA3/UNV1 ½ Wall with Junction Box NV2LCHBF1/UNV1 NV2LWHBF1/UNV1 Wall 11 1/4 [285.1] 6 7/8 [175] 3/4" NPT HUB 1/2" REDUCER SUPPLIED 15/16 [23.9] 8 1/8 [206.7] Stanchion 11 13/16 [299.9] ¾ Wall with Junction Box NV2LCHBF2/UNV1 NV2LWHBF2/UNV1 ½ Ceiling NV2LCHF1/UNV1 NV2LWHF1/UNV1 3 7/8 [99] 4 3/4 [121.3] 1-1/4" HUB 45 ¾ Ceiling NV2LCHF2/UNV1 NV2LWHF2/UNV1 ½ Wall NV2LCHT1/UNV1 NV2LWHT1/UNV1 ¾ Wall NV2LCHT2/UNV1 NV2LWHT2/UNV1 1-¼ Stanchion NV2LCHJ4/UNV1 NV2LWHJ4/UNV1 Options Suffix (added to part #) Description 1/4 [5.6] 1 [25.4] 1 3/4 [44] 8 3/4 [221.7] 5 7/8 [149.1] 1 3/4 [44] 1 [25.4] 1 3/4 [44] 7 1/16 1 [179.7] [25.4] Ø4 15/16 [125.2] 8 3/4 [221.7] S891 S896 Frosted lens (NEC version only) Teflon coated lens (NEC version only) 1 [25.4] 1 3/4 [44] S902 High temperature option (up to 55 C ambient temperature) BR Brazil (CEPEL certification) (IEC version only) Pendant Ceiling Family tree 8 3/4 [221.7] 8 3/4 [221.7] Class I, Div. 2; Class II, Div. 1, Gr. F&G Class I, Div. 2; Class II, Div. 2, Gr. F&G VXF 10 VXFT 10 VXF 20 VXFT20 Ø4 9/16 [Ø116.0] Ø1/4 [Ø7.1] VXW2 VLA1 VLA2 VLA3 VLHR VXJ4 V2L LED Housing VXT20 VXF 10 VXFT 10 VXF 20 VXFT20 Complete luminaire consists of LED housing and cover: VLA pendant or a VLHR adapter and VX series mounting module 4 11/16 [119.8] 3 7/8 [99.2] 4 1/2 [114.7] VLA1 1/2" NPT HUB VLA2 3/4" NPT HUB VLA3 1" NPT HUB 2 1/8 [53.9] 3 7/8 [98.5] 2 1/8 [53.4] 5 1/2 NPT OR 3/4" NPT HUB 5 3/4 [146.2] 6

Photometric data Zonal lumens Vaporgard LED (22 Watt) Zone Lumens % Lumen 0-30 468 28.65 0-40 772 47.30 0-60 1374 84.15 0-90 1633 100.00 40-90 860 52.70 60-90 259 15.85 90-180 0 0.00 0-180 1633 100.00 Isofootcandle F E D C B A Distance to mounting height Isofootcandle chart shows illuminance in footcandles at ground level Mtg. height A B C D E F 6 10.00 5.00 2.00 1.00 0.50 0.20 8 5.62 2.81 1.13 0.56 0.28 0.11 10 3.60 1.80 0.72 0.36 0.18 0.07 12 2.50 1.25 0.50 0.25 0.13 0.05 14 1.84 0.92 0.37 0.18 0.09 0.04 7

U.S. (global headquarters): Eaton's Crouse-Hinds Division 1201 Wolf Street Syracuse, NY 13208 (866) 764-5454 FAX: (315) 477-5179 FAX Orders Only: (866) 653-0640 crousecustomerctr@eaton.com Canada Toll Free: 800-265-0502 FAX: (800) 263-9504 FAX Orders only: (866) 653-0645 Mexico/Latin America/Caribbean 52-555-804-4000 FAX: 52-555-804-4020 Middle East (Dubai) 971 4 8066100 FAX: 971 4 8894813 chmesales@eaton.com Singapore 65-6645-9888 FAX: 65-6297-4819 Korea 82-2-3484-6783 82-2-3484-6778 CCHK-sales@ Australia 61-2-8787-2777 FAX: 61-2-9609-2342 For more information: ventascentromex@eaton.com chsi-sales@ CEASales@ If further assistance is required, please contact an authorized Eaton Distributor, Sales Office, or Customer Service Department. Europe (Germany) 49 (0) 6271 806-500 49 (0) 6271 806-476 sales.cch.de@ China 86-21-2899-3600 FAX: 86-21-2899-4055 cchsales@ India 91-124-4683888 FAX: 91-124-4683899 cchindia@ Eaton's Crouse-Hinds 1201 Wolf Street Syracuse, NY 13208 Crouse-Hinds.com Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 2017 Eaton All Rights Reserved Printed in USA Publication No. 5132-0917 September 2017 Eaton is a registered trademark. All other trademarks are property of their respective owners.