LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

Similar documents
Bdl60u Fluorescent Emergency Ballast

Emergency Lighting. Product Guide LED. The right source for the. right light

Compatible with most electronic AC ballasts Maintenance-free, long-life, high temperature Ni-Cad battery Durable, heavy duty steel housing 5-year

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

NYC Approved Product Series

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

CDL8 LED Architectural

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

BACKUP BATTERY INSTALLATION INSTRUCTIONS

LED RETROFIT CONVERSION KITS

Emergency TLED Lighting Retrofit 101. December 6 th 2017

2013 Nonresidential Appendices Appendix NA8-1. Appendix NA8 Luminaire Power... 1 NA8.1 Luminaire Power... 1

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

The New Lux-Ray LED Emergency Lighting

HIGH BAY APPLICATIONS

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

SUSTAINABLE LIGHTING SOLUTIONS

ESRB and ESRN Installation & Safety Instructions

Explosion Proof Exit Sign - Class I, Division I - IP65-120V/277VAC - Emergency Battery Back-Up

SECTION INTERIOR LIGHTING

Exit/Emergency Lighting Guide

SERVICE BY QUALIFIED PERSONNEL ONLY

Catalog Number. Notes

LED RETROFIT SOLUTIONS

WINDSOR FOREST HIGH SCHOOL HVAC REPLACEMENT ADDENDUM #2 SAVANNAH CHATHAM COUNTY PUBLIC SCHOOL SYSTEM FEBRUARY 18, 2016

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

Dimmable General Area Use High Bay 320 Watt LED Light Fixture - Low Profile - High Efficiency

SECTION INTERIOR LIGHTING

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

1 General Description

MANUFACTURED IN THE UK

TROFFER RETROFIT KIT (TRK)

Honeywell Durafit LED Retrofit Kit

Nightfall. led emergency egress lighting

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

IOTA Exit Signs. IOTA Emergency Fixtures

CHINESE NEW YEAR DEADLINE SOLUTIONS

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519

SECTION INTERIOR LIGHTING

LED RETROFIT CONVERSION KITS

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

Lumination LED Luminaires

Project. Comments. Prepared by. - EZ Hang feature facilitates fast - Prorated 5-year battery warranty - Overload / Short Circuit - NEC/OSHA

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

SECTION LIGHTING

SECTION INTERIOR LIGHTING

Lumination LED Luminaires

BALLAST SOURCE EB- Electronic ballast BALLAST QUANTITY. 1-(1) 4-light ballast LAMP SPECIFICATIONS SPECIFICATIONS

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

Solid State Lighting Sub-Assembly Interfaces for Luminaires. Andrew D. Jackson Philips Lighting Corporate Regulatory and Certification Laboratory

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

FPLHB - Fidelux Premier Linear Highbay

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

BIANCO SENSOR FLUSH MOUNT 15W MODEL # GBCL400HFSR

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

INERIS 01ATEX0060 (standard) TR CU (marking upon request, ordering code to be required)

But act fast: your order must be received by December 21st and ship by December 28th. Order quantity limited to supply in stock.

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

LED Shoplight fixture

How to light a small storage space rabdesign.ca 1

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

D O M E S T I C LED. Lighting C O M M E R C I A L

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

LED FIXTURE CATALOG. Shining light into the future

Product Specifications MaxLumen MRI LED Diffused Lighting

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

Pacific Gas and Electric Company Energy Efficiency Rebates for Your Business. Lighting Rebate Catalog Saving energy for a brighter future

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

BAYMAX TM LED LINEAR HIGHBAY FIXTURE BLHT SERIES

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

HIGH BAY/ LOW BAY. LED INDOOR HIGH BAY/LOW BAY LIGHTS Linear and Round Luminaires & Accessories

SECTION EXTERIOR LIGHTING

Architectural / led luminaires

UBC Technical Guidelines Section Edition Interior Building Lighting Page 1 of 5

HIGH LUMINOUS EFFICIENCY

Operation Manual. ParaBeam 400/200 Series. ParaBeam 400 Center Mount. ParaBeam 400 Pole-Op

Motion Sensor. Specifications

Related Sections: TBD. Effective Date: January 1, 2016

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

DISTRIBUTOR SELECT COLLECTION. EMERGI-LITE Full range of emergency lighting solutions

Lighting Solutions. from a Leader in Light Source Technology

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

Battery charger modules

Transcription:

LUCE 1 TL indoor / damp Job/Location: Contractor: Prepared By: Job Type: Date: The LUCE-1TL thinline emergency ballast is designed to provide emergency illumination to existing or new fluorescent luminaires. The LUCE-1TL consists of an internal nickel cadmium battery, charger and electronic circuit contained in a thinline steel housing. NOTE: 3 year warranty standard, see details on next page. Installation: The LUCE-1TL thinline emergency ballast does not effect the normal operation of a luminaire. Designed to be used with either switched or unswitched luminaires. If a switched luminaire is used, an unswitched hot lead must be connected to the LUCE-1TL. The LUCE-1TL must be fed from the same branch circuit as the AC ballast. The LUCE-1TL may be installed inside, on top or remote of the luminaire. Installation is not recommended with luminaires where the ambient temperature may fall below 0C for extended periods. specifications: internal The LUCE-1TL thinline emergency ballast utilizes a high temperature nickel cadmium battery, charger and electronic circuit. All components are contained within a low profile, compact steel housing that measures 10 L x 2 W x 1.1875 H. A single, low voltage LED monitor / test switch is standard equipment. The LUCE-1TL is designed to operate for a minimum of 90 minutes and complies with the emergency standards set forth by the current NEC requirements. UL listed for installation inside, on top of, or remote from the luminaire. specifications: external The LUCE-1TL features a solid-state charging indicator light to monitor the charger and battery, a single-pole test switch, and installation hardware. Listed for installation inside, on top of, or remote from the fixture. A B C D 1.19 10 2 9.5 LUCE-1TL 30mm 254mm 51mm 241mm ordering logic LUCE-1TL 450-500 lumens, (1) 8W-34W T5, T8 or T12 fluorescent lamp (including rapid start, U-shape and circline) or (1) 13W - 18W 4-pin compact fluorescent lamp (without integral starter). builder 150

Technical specifications: electrical BATTERY: The LUCE-1TL thinline emergency ballast utilizes a specially constructed high temperature nickel cadmium battery, charger and electronic circuit. A single, low voltage LED monitor / test switch is standard equipment. The LUCE-1TL is designed to operate for a minimum of 90 minutes. CIRCUIT: The LUCE-1TL thinline emergency ballast can be used with one (1) 8W-34W T5, T8 or T12 fluorescent lamp (including rapid start, U-shape and circline) or one (1) 13W - 18W 4-pin compact fluorescent lamp (without integral starter). The LUCE-1TL is compatible with most electronic and dimming AC ballasts. Rated for use in damp location luminaires. The LUCE-1TL is not suitable for use in air handling heated air outlet luminaires, wet or hazardous rated luminaires. Please contact the factory for specific lamp and ballast compatibility. The LUCE-1TL features AC output to ensure compatibility with newer lamp technologies (low mercury, for example). This feature also helps in prolonging the lamp life. A standard three (3) second time delay prevents false tripping of the AC ballasts end of life shut down circuitry. specifications: mechanical The LUCE-1TL features a 10 x 2 x 1.88 durable thinline steel housing. emergency illumination During AC power failure, the LUCE-1TL thinline immediately switches to the emergency mode, keeping one lamp illuminated at a reduced lumen output for a minimum required 90 minutes. When AC is restored, the LUCE-1TL automatically returns to the charging mode. The integrated time delay feature delays AC ballast operation for three (3) seconds to prevent false tripping of the AC ballasts end of life shut down circuitry. The LUCE-1TL thinline emergency ballast produces an initial 500 lumens during emergency operation. Designed to operate a single (1) lamp for a period no less then 90 minutes. Lumen output is less when using a compact fluorescent lamp. UL and code compliance The LUCE-1TL thinline emergency ballast has been tested by Underwriters Laboratories in accordance with the standards set forth in UL 924, Emergency Lighting and Power Equipment, and is UL Listed for factory or field installation. Emergency illumination time exceeds the National Electrical Code (NEC), Life Safety Code (NFPA LSC) and UL 90-minute requirements. warranty The LUCE-1TL thinline series features a 3-year factory warranty. Deliberate damage, misuse, improper installation and/or application effectively cancel the warranty. product summary UL Listed Dual Voltage Input Test Switch/Charge Indicator Temperature Rating (Ambient) Damp Location Factory or Field installation 120/277VAC 60Hz Low Voltage monitor LED and test switch 0 C TO +50 C (32 F TO 122 F) Illumination Ac Input Current Battery Charging Current Weight 90 Minutes 130mA 110mA 1.4LBS (0.6 KG) Initial Light Output Ac Input Power Rating Recharge Time 450-500 Lumens 3.0 Watts 24 Hours Dimensions Battery Full Warranty 4.8V / 2.0Ah 10 L x 2 W x 1.1875 H High-temperature (254mm x 50.8mm x 30.16mm) Maintenance-free Mounting center 9.5625 Nickel Cadmium 3 years (NOT pro-rated) 151

LUCE 2 TL indoor / damp Job/Location: Contractor: Prepared By: Job Type: Date: The LUCE-2TL thinline emergency ballast is designed to provide emergency illumination to existing or new fluorescent luminaires. The LUCE-2TL consists of an internal nickel cadmium battery, charger and electronic circuit contained in a thinline steel housing. NOTE: 3 year warranty standard, see details on next page. Installation: The LUCE-2TL thinline emergency ballast does not effect the normal operation of a luminaire. Designed to be used with either switched or unswitched luminaires. If a switched luminaire is used, an unswitched hot lead must be connected to the LUCE-2TL. The LUCE-2TL must be fed from the same branch circuit as the AC ballast. The LUCE-2TL may be installed inside, on top or remote of the luminaire. Installation is not recommended with luminaires where the ambient temperature may fall below 0C for extended periods. specifications: internal The LUCE-2TL thinline emergency ballast utilizes a high temperature nickel cadmium battery, charger and electronic circuit. All components are contained within a low profile, compact steel housing that measures 13.375 L x 2.25 W x 1.3125 H. A single, low voltage LED monitor / test switch is standard equipment. The LUCE-2TL is designed to operate for a minimum of 90 minutes and complies with the emergency standards set forth by the current NEC requirements. UL listed for installation inside, on top of, or remote from the luminaire. specifications: external The LUCE-2TL features a solid-state charging indicator light to monitor the charger and battery, a single-pole test switch, and installation hardware. Listed for installation inside, on top of, or remote from the fixture. A B C D 1.31 13.38 2.25 12.75 LUCE-2TL 33mm 340mm 57mm 324mm ordering logic LUCE-2TL 700 lumens, (1) 8W-40W T5, T8 or T12 fluorescent lamp (including rapid start, U-shape and circline) or (1) 13W - 50W 4-pin compact fluorescent lamp (without integral starter) builder 152

Technical specifications: electrical BATTERY: The LUCE-2TL thinline emergency ballast uses a specially constructed, high-temperature nickel cadmium battery. CIRCUIT: The LUCE-2TL thinline emergency ballast can be used with one(1) 8W-40W T5, T8 or T12 fluorescent lamp (including rapid start, U-shape and circline) or one (1) 13W - 50W 4-pin compact fluorescent lamp (without integral starter). The LUCE-2TL is compatible with most electronic and dimming AC ballasts. Rated for use in damp location luminaires. The LUCE-2TL is not suitable for use in air handling heated air outlet luminaires, wet or hazardous rated luminaires. Please contact the factory for specific lamp and ballast compatibility. The LUCE-2TL features AC output to ensure compatibility with newer lamp technologies (low mercury, for example). This feature also helps in prolonging the lamp life. A standard three (3) second time delay prevents false tripping of the AC ballasts end of life shut down circuitry. specifications: mechanical The LUCE-2TL features a 13.38 x 2.25 x 1.31 durable thinline steel housing. emergency illumination During AC power failure, the LUCE-2TL thinline immediately switches to the emergency mode, keeping one lamp illuminated at a reduced lumen output for a minimum required 90 minutes. When AC is restored, the LUCE-2TL automatically returns to the charging mode. The integrated time delay feature delays AC ballast operation for three (3) seconds to prevent false tripping of the AC ballasts end of life shut down circuitry. The LUCE-2TL thinline emergency ballast produces an initial 700 lumens during emergency operation. Designed to operate a single (1) lamp for a period no less then 90 minutes. Lumen output is less when using a compact fluorescent lamp. UL and code compliance The LUCE-2TL thinline emergency ballast has been tested by Underwriters Laboratories in accordance with the standards set forth in UL 924, Emergency Lighting and Power Equipment, and is UL Listed for factory or field installation. Emergency illumination time exceeds the National Electrical Code (NEC), Life Safety Code (NFPA LSC) and UL 90-minute requirements. warranty The LUCE-2TL thinline series features a 3-year factory warranty. Deliberate damage, misuse, improper installation and/or application effectively cancel the warranty. product summary UL Listed Dual Voltage Input Test Switch/Charge Indicator Temperature Rating (Ambient) Damp Location Factory or Field installation 120/277VAC 60Hz Low Voltage monitor LED and test switch 0 C TO +50 C (32 F TO 122 F) Illumination Ac Input Current Battery Charging Current Weight 90 Minutes 180mA 160mA 2.0LBS (0.9 KG) Initial Light Output Ac Input Power Rating Recharge Time 700 Lumens 2.7 Watts 24 Hours Dimensions Battery Full Warranty 6V / 2.5Ah 13.375 L x 2.25 W x 1.3125 H High-temperature (339.73mm x 57.15mm x33.3400mm) Maintenance-free Mounting center 12.875 Nickel Cadmium 3 years (NOT pro-rated) 153

LUCE 3-TLP indoor / damp HOME Job/Location: Contractor: Prepared By: Job Type: Date: The LUCE 3-TLP thinline emergency ballast is designed to provide emergency illumination to existing or new fluorescent luminaires. The LUCE 3-TLP consists of an internal nickel cadmium battery, charger and electronic circuit contained in a thinline steel housing. NOTE: 3 year warranty standard, see details on next page. Installation: The LUCE 3-TLP thinline emergency ballast does not effect the normal operation of a luminaire. Designed to be used with either switched or unswitched luminaires. If a switched luminaire is used, an unswitched hot lead must be connected to the LUCE 3-TLP. The LUCE 3-TLP must be fed from the same branch circuit as the AC ballast. The LUCE 3-TLP may be installed inside, on top or remote of the luminaire. Installation is not recommended with luminaires where the ambient temperature may fall below 0 C for extended periods. specifications: internal The LUCE 3-TLP thinline emergency ballast utilizes a high temperature nickel cadmium battery, charger and electronic circuit. All components are contained within a low profile, compact steel housing that measures 14.5 L x 2.1 W x 1.1 H. A single, low voltage LED monitor / test switch is standard equipment. The LUCE 3-TLP is designed to operate for a minimum of 90 minutes and complies with the emergency standards set forth by the current NEC requirements. UL listed for installation inside, on top of, or remote from the luminaire. The LUCE 3-TLP may be mounted up to 50 feet away. specifications: external The LUCE 3-TLP features a solid-state charging indicator light to monitor the charger and battery, a single-pole test switch, and installation hardware. Listed for installation inside, on top of, or remote from the luminaire. A B C 1.1 14.5 2.1 LUCE 3-TLP 28mm 368mm 53mm ordering logic 1400 lumens, 14W through 54W (2-4 ) T5 and T8 single pin or bipin for one lamp, Instant Start and Rapid Start, 14W through 39W (2-4 ) T5 and LUCE 3-TLP T8 single pin or bipin for two lamp, Instant Start and Rapid Start, 18W through 50W (4 -pin) long compact Rapid Start, or 32W (4 pin) compact, 24W through 32W U-Bend FBT8 fluorescent lamps. builder 212

Technical specifications: electrical BATTERY: The LUCE 3-TLP thinline emergency ballast uses a specially constructed, high-temperature nickel cadmium battery. CIRCUIT: The LUCE 3-TLP thinline emergency ballast can be used with 14W through 54W (2-4 ) T5 and T8 single pin or bipin for one lamp, Instant Start and Rapid Start, 14W through 39W (2-4 ) T5 and T8 single pin or bipin for two lamp, Instant Start and Rapid Start, 18W through 50W (4 -pin) long compact Rapid Start, or 32W (4 pin) compact, 24W through 32W U-Bend FBT8 fluorescent lamps with an initial output of up to 1400 lumens for one or two lamps. The LUCE 3-TLP is compatible with most electronic ballasts. Rated for use in damp location luminaires. The LUCE 3-TLP is not suitable for use in air handling heated air outlet luminaires, wet or hazardous rated luminaires. Please contact the factory for specific lamp and ballast compatibility. The LUCE 3-TLP features AC output to ensure compatibility with newer lamp technologies (low mercury, for example). This feature also helps in prolonging the lamp life. A standard three (3) second time delay prevents false tripping of the AC ballasts end of life shut down circuitry. specifications: mechanical The LUCE 3-TLP features a 14.5 x 2.1 x 1.1 durable thinline steel housing and weighs 3.3 lbs. emergency illumination During AC power failure, the LUCE 3-TLP thinline immediately switches to the emergency mode, keeping one or two lamp(s) illuminated at a reduced lumen output for a minimum required 90 minutes. When AC is restored, the LUCE 3-TLP automatically returns to the charging mode. The integrated time delay feature delays AC ballast operation for three (3) seconds to prevent false tripping of the AC ballasts end of life shut down circuitry. The LUCE 3-TLP thinline emergency ballast produces an initial 1400 lumens during emergency operation. Designed to operate one (1) or two (2) lamps for a period no less then 90 minutes. Lumen output is less when using a compact fluorescent lamp. UL and code compliance The LUCE 3-TLP thinline emergency ballast has been tested by Underwriters Laboratories in accordance with the standards set forth in UL 924, Emergency Lighting and Power Equipment, and is UL Listed for factory or field installation. Emergency illumination time exceeds the National Electrical Code (NEC), Life Safety Code (NFPA LSC) and UL 90-minute requirements. warranty The LUCE 3-TLP thinline series features a 3-year factory warranty. Deliberate damage, misuse, improper installation and/or application effectively cancel the warranty. HOME product summary UL Listed Dual Voltage Input Test Switch/Charge Indicator Temperature Rating (Ambient) Damp Location Factory or Field installation 120/277VAC 60Hz Low Voltage monitor LED and test switch 20 C TO + 50 C (68 F TO 122 F) Illumination Ac Input Current Battery Charging Current Weight 90 Minutes 180mA 160mA 3.3LBS (1.5 KG) Initial Light Output Ac Input Power Rating Recharge Time Operation Compatability 1400 Lumens 3.7 Watts 24 Hours Electronic ballasts (not dimmable) Dimensions Battery Full Warranty 6V / 2.5Ah 14.5 L x 2.1 W x 1.1 H High-temperature (368.3mm x 53.34mm x 27.94mm) Maintenance-free Mounting center 12.875 Nickel Cadmium 3 years (NOT pro-rated) 213