Multi V Air Conditioner SVC MANUAL(Exploded View)

Similar documents
Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View)

(60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A)

Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View)

LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static)

Room Air Conditioner SVC MANUAL(Exploded View)

SVC Manual(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Single Zone Air Conditioner SVC MANUAL(General)

Easy to service. Up to 9 indoor units can be connected

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)

Highly Efficient,Powerful Heating and Cooling.

SVC Manual(Exploded View)

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

duct-free air conditioning systems Art cool inverter flex multi-split

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

Single Zone Air Conditioner SVC MANUAL (Exploded View)

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

Air Conditioning System

DESIGN & TECHNICAL MANUAL

AIR CONDITIONERS SPLIT TROPICAL RANGE. FLAT SPLIT - Heat & Cool T1 R410a AMD K BTU EAN: AMD K BTU EAN:

Ceiling Cassette Type Single-Zone Air Conditioning

DESIGN & TECHNICAL MANUAL

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

ENGiNEERiNG AND SPECiFiCATioNS GuiDE

ENGiNEERiNG AND SPECiFiCATiONS GuiDE

DESIGN & TECHNICAL MANUAL

(Non-Inverter & Inverter) R410A

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Multi Air Conditioner Indoor Unit SVC MANUAL(General)

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Wall Mounted Split Systems

DESIGN & TECHNICAL MANUAL

AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-02A(5BPU0-01A)

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Ductless Split Systems Ceiling Cassette Heat Pumps

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

AUS-DU112. New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : FAX :

PTAC Type (60Hz/R410A) 6RWU0-03A

Heat Pump Air Conditioning Systems

Engineering Data Book

SiUS181631EA. Service Manual. Multi-Split Type Air Conditioners RMXS-L Series. [Applied Models] Inverter Multi : Heat Pump

Pure Efficiency Meets Healthy Living NEW 2013

Inverter Single (50Hz/R410A) 5RMA2-01B(5RMA2-01A)

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

SiUS RXYQ72, 96, 144, 168, 192MTJU R-410A Heat Pump 60Hz RXYQ72MTJU RXYQ96MTJU RXYQ144MTJU RXYQ168MTJU RXYQ192MTJU

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Inverter console UFV system. Compact design and personalised air flow selection

1. INDOOR UNITS... MSZ-FH-3 2. OUTDOOR UNITS... MSZ-FH-4 3. SYSTEM... MSZ-FH-5

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Single "A" Air Conditioner SVC MANUAL(General)

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

The latest innovation in cool 7 YEAR 1 YEAR WARRANTY ON PARTS WARRANTY ON COMPRESSORS

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Up to SEER 26.1 Wall Mount Heat Pump

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Brief exposure to greenery in urban environments can relieve stress levels and your well-being.

Packaged Air Conditioners Duct Connection Type [50Hz] FDMG-AV1(S) Series Cooling Only

AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03A(Replace:5BPU0-02A)

Ducted inverter reverse cycle air conditioning

Product Brochure Smart Power. Low Profile Ducted

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

INDOOR UNIT PRODUCT OVERVIEW

DESIGN & TECHNICAL MANUAL

Hi - Wall Split Systems 12K - 18K - 24K

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Universal System Air Conditioner

Floor Standing. FV Series PLXSPH1502. COOLING ONLY [60Hz]

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

2 &3-4 Head Multi System

Just feel well. 2017/2018 Air conditioning

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

Ductless Split Systems Wall-mounted, Multizone Heat Pump

Transcription:

Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU07GQAA2 ARNU09GQAA2 ARNU12GQAA2 ARNU15GQAA2 CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service personnel.

1. Specification Cooling Capacity Heating Capacity Casing Dimensions (WxDxH) Coil Fan Type Model Unit kw kcal/h Btu/h kw kcal/h Btu/h Body inch Front Panel inch Rows x Columns x FPI Face Area m 2 Type Motor utput x Number W Running Current Air Flow Rate(H/M/L) Drive Motor type Temperature Control A CMM cfm Sound Absorbing Thermal Insulation Material Safety Device Liquid Side (inch) Pipe Connections Gas Side (inch) Drain(D/ID) Net Weight Body kg(lbs) Noise Level(Sound Press, 1.5m, H/M/L) db(a) Power Supply Ø, V, Hz Refrigerant Control Power cable 2 (CV) Transmission cable 2 (VCTF-SB) Panel Color CNSLE ARNU07GQAA2 ARNU09GQAA2 2.2 2.8 1,900 2,400 7,500 9,600 2.5 3.2 2,200 2,800 8,500 10,900 Galvanized Steel Plate Galvanized Steel Plate 600x700x210 600x700x210 23.6x27.6x8.3 23.6x27.6x8.3 - - - - 19x2x19 19x2x19 0.2 0.2 Turbo fan Turbo fan 48 x 1 48 x 1 0.3 0.3 6.7/5.9/4.8 6.7/5.9/4.8 236/209/170 236/209/170 Direct Direct BLDC BLDC Microprocessor, Thermostat Microprocessor, Thermostat for cooling and heating for cooling and heating Foamed polystrene Foamed polystrene Fuse Fuse 17/12.2 17/12.2 14(30.9) 14(30.9) 37/34/28 37/34/28 1, 220 ~ 240, 50 1, 220 ~ 240, 50 1.5 x 3C 1.5 x 3C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Morning Fog Morning Fog Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB utdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Interconnecting Piping Length 7.5m Level Difference of Zero Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB utdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB Interconnecting Piping Length 7.5m Level Difference of Zero 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. : Electronic Expansion Valve Conversion Formula kcal/h= kw x 860 Btu/h = kw x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 nly for training and service purposes - 2 - LGE Internal Use nly

Cooling Capacity Heating Capacity Casing Dimensions (WxDxH) Coil Fan Type Model Unit kw kcal/h Btu/h kw kcal/h Btu/h Body inch Front Panel inch Rows x Columns x FPI Face Area m 2 Type Motor utput x Number W Running Current Air Flow Rate(H/M/L) Drive Motor type Temperature Control A CMM cfm Sound Absorbing Thermal Insulation Material Safety Device Liquid Side (inch) Pipe Connections Gas Side (inch) Drain(D/ID) Net Weight Body kg(lbs) Noise Level(Sound Press, 1.5m, H/M/L) db(a) Power Supply Ø, V, Hz Refrigerant Control Power cable 2 (CV) Transmission cable 2 (VCTF-SB) Panel Color CNSLE ARNU12GQAA2 ARNU15GQAA2 3.6 4.5 3,100 3,900 12,300 15,400 4.0 5.0 3,400 4,300 13,600 17,100 Galvanized Steel Plate Galvanized Steel Plate 600x700x210 600x700x210 23.6x27.6x8.3 23.6x27.6x8.3 - - - - 19x2x19 19x2x19 0.2 0.2 Turbo fan Turbo fan 48 x 1 48 x 1 0.3 0.3 7.5/5.9/4.8 8.7/6.7/5.9 265/209/170 307/236/209 Direct Direct BLDC BLDC Microprocessor, Thermostat Microprocessor, Thermostat for cooling and heating for cooling and heating Foamed polystrene Foamed polystrene Fuse Fuse 17/12.2 17/12.2 14(30.9) 14(30.9) 39/34/28 42/37/31 1, 220 ~ 240, 50 1, 220 ~ 240, 50 1.5 x 3C 1.5 x 3C 1.0 ~ 1.5 x 2C 1.0 ~ 1.5 x 2C Morning Fog Morning Fog Notes: 1. Capacities are based on the following conditions: Cooling Indoor temp. 27 C[80.6 F]DB/ 19 C[66.2 F]WB utdoor temp. 35 C[95 F]DB/ 24 C[75.2 F]WB Interconnecting Piping Length 7.5m Level Difference of Zero Heating Indoor temp. 20 C[68 F]DB/ 15 C[59 F]WB utdoor temp. 7 C[44.6 F]DB/ 6 C[42.8 F]WB Interconnecting Piping Length 7.5m Level Difference of Zero 2. Capacities are net capacities 3. Due to our policy of innovation some specifications may be changed without prior notification 4. To be added for more available Models 5. : Electronic Expansion Valve Conversion Formula kcal/h= kw x 860 Btu/h = kw x 3412 cfm = m 3 /min x 35.3 l/s = CMM x 1000/60 nly for training and service purposes - 3 - LGE Internal Use nly

2. List of Functions Category Air flow Air purifying Installation Reliability Convenience Individual control Special function kit Function Air supply outlet Airflow direction control(left & right) Airflow direction control(up & down) Auto swing(left & right) Auto swing(up & down) Airflow steps(fan/cool/heat) Chaos swing Chaos wind(auto wind) Jet cool(power wind) Swirl wind Deodorizing filter Ion Generator Prefilter(washable / anti-fungus) Drain pump E.S.P. control Electric heater(operation) High ceiling operation Hot start Self diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Standard wired remote controller Deluxe wired remote controller Simple wired remote controller Wired remote controller(for hotel use) Wireless remote controller(simple) Wireless LCD remote control Zone control CTIE Electro thermostat ARNU07GQAA2, ARNU09GQAA2, ARNU12GQAA2, ARNU15GQAA2 2 Manual Auto 4/5/4 Accessary Accessary : Applied : Not applied : No relation ption : Model name & price are different according to options, and assembled in factory with main unit. Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. nly for training and service purposes - 4 - LGE Internal Use nly

3. Piping Diagrams Heat Exchanger Filter :Cooling :Heating Th3 Turbo Fan Th2 Filter Th1 lndoor unit Refrigerant pipe connection port diameter Model ARNU07GQAA2 ARNU09GQAA2 ARNU12GQAA2 ARNU15GQAA2 Gas [unit: (inch)] Liquid LC. Th1 Th2 Th3 Description Room thermistor Pipe in thermistor Pipe out thermistor nly for training and service purposes - 5 - LGE Internal Use nly

4. Wiring Diagrams QA chassis WIRED REMTE CNTRLLER CN -PWER CN -MTR CN- CN-DISPLAY CN-PTIN CN-RM CN-PIPE/IN CN-PIPE/UT CN-REM CN VANE2 CN VANE1 CN-AIRC CN-485 nly for training and service purposes - 6 - LGE Internal Use nly

5. Exploded View QA Model Indoor Unit 148000B 145200A 148000A W49810 152311 352380A 135312 147581A 147582A 146811A 137210 437213 733010 352380B 135080A 135311 152500A 135080B 145200B 147581B 135080C W4811 266090 152500B 147582B 146811B 349600 268711A W6640B 349490 354210 346810 359012 135500 268711D 268711C W3110 263230A W6640A 268711G 55211G 263230B 352118 263230C 249951 145200C Thermistor 1 263230A Air Housing Color:Yellow Thermistor 2 263230B Eva.In Housing Color:White Thermistor 3 263230C Eva.ut Housing Color:Red nly for training and service purposes - 7 - LGE Internal Use nly

P/N : MFL62247102 FEBRUARY, 2010