Construction Products Regulation (CPR) Update. Graham Simons Technical Manager, FIA

Similar documents
The EN54 Part 2 and 4 Fire System

EN54 Part 23 Made Easy CPD PRESENTED BY SIMON ADAMS GENT BY HONEYWELL

Guideline Construction Products Regulation (EU) 305/20122

False Alarm Management. Graham Simons FIA Technical Manager

Consultant Specification AGILE Wireless Fire Detection System

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Guided Learning Hours (GLH) 16 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 18

The EN54 Part 2 & 4 Fire System

BS 5839 Part 1 : 2013 Changes. By Don Scott

For the Design, Installation, Commissioning & Maintenance of Fire Detection and Fire Alarm Systems

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

System 800 Addressable Fire Detection & Alarm System

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

The effects on the UK Fire Industry. Paul Pope Eng.Tech AIFireE

MINERVA MX. 800 Series Ancillary Equipment

KFP-CF Series Operation Manual

Algo-Tec 6500/6600 INTERACTIVE ADDRESSABLE FIRE CONTROL SYSTEM

Fire Alarm Control Panel. System Maintenance and Log Book

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

BS 5839: Part THE CHANGES

Guided Learning Hours (GLH) 8 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 10

Technical reference Reference & design

The EN54 Part 2, 4 and 13 Fire System

ZP2 Series Operation Manual

General Routing Interface

one Operating instructions SenTRI ONE panel-based Fire detection and alarm system

Input module, input/output modules

PROFYRE C8 USER MANUAL, MAINTENANCE GUIDE & LOG BOOK FIRE ALARM CONTROL PANEL USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

1. Terms defined in the Construction Products Regulation (CPR)

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

The Danish Energy Agency will carry out inspections in June 2013

Guidance Note FIA Application Guidance on BS :2015

FIRE ALARM CONTROL PANEL FVC01-08

USER MANUAL 10 YEAR LIFE SMOKE ALARM

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

USER MANUAL & MAINTENANCE GUIDE OG OO

ISLE OF WIGHT FIRE & RESCUE SERVICE

Technical standards to support the evolution of technology enabled care services

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

False alarms research work Raman Chagger (BRE Global) 18 th June 2015 Firex International. Part of the BRE Trust

FieldServer Driver - Serial FS Grinnell TFX Minerva

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

Fact File 48 Guide to BS EN 54-13:2017 Fire Detection and alarm systems:

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Maintenance of Fire Systems

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

Automatic Fire Alarm System

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

SAFETY/ SECURITY - FIRE FIGHTING INTEGRATED SYSTEMS

USER MANUAL, MAINTENANCE GUIDE & LOG BOOK

A GUIDE TO THE REGULATORY REFORM ORDER (FIRE SAFETY) 2005 (RRO)

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Input module, input/output module

ALL YOU NEED TO KNOW ABOUT THE NEW STANDARDS IN ONE HANDY POCKET GUIDE. Updated for 2016 to include IA1501. Brought to you by: In association with:

Operating instructions Vigilon panel and Network node Fire detection and alarm system

HG Home Guardian Advanced Home Energy, Safety and Security Management

Fire control panels FC360

Control Panel User Guide

PRODUCT GUIDE & INFORMATION. Professional Fire & Carbon Monoxide Solutions

highline SVCS-1 INSTALLATION & USER MANUAL SMOKE VENT CONTROL SYSTEM * enclosure design may vary software version: SVCS1r6 SVCS1r7 SVCS1r10

Installation, Operating and Maintenance Manual

Multi line separator module

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Fire control panel for modernization

Operating instructions SENTRI4 Control panel based Fire detection and alarm system

MULTIFUNCTIONAL SYSTEM

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

LOG BOOK & CERTIFICATES

SOUTH AFRICAN NATIONAL STANDARD

FIRE & LIFE SAFTEY STANDARD

2004 AUSTRALIAN STANDARDS UPDATE

Model: Ei450. Instruction Manual

Guidance Note. Visual Alarm Devices: Conflict between BS 5839 and EN 54-23

Output module (230 V)

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

LPS 1014 Scheme Requirements for certificated fire detection and alarm system firms. Presented by - Reg Grigg LPCB

Training Courses. The most comprehensive technical fire safety training programme.

Summary of changes between PD 6662:2010 and PD 6662:2017 a guide

DS9400 Series. Release Notes for Firmware V2.07. Fire Alarm Control Panel

Alarm Controller Fire and CO

Mimic display driver, LED ribbon cable

Installation Manual Premier 412/816/832. Issue 10

USER MANUAL CEF AP28 CONTROL PANEL

User guide. for smoke detector

OH720, OP720, HI720, HI722

Fire detection and alarm system Operating instructions

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

YOUR GUIDE TO UNDERSTANDING CPR

XFP NETWORKABLE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANEL. user manual and log book. approved document no. DFU Rev 1

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Loss Prevention Standard

FIRE SAFETY LOG BOOK

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Guidance Note Guide to the changes in BS

FEC403EN Installation Manual

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Guidance Note No 19/1. CE Marking windows and doorsets

Transcription:

Construction Products Regulation (CPR) Update Graham Simons Technical Manager, FIA

What are we talking about? Construction Products Regulation 305/2011 EU (CPR) Replaced Construction Products Directive (CPD) Declaration of Performance (DoP) replaced the CPD, DoC Effective since July 2013 CPR has been updated by Delegated Regulation 157/2014 CIE Control and Indicating Equipment EN 54-2, Options with Requirements (OwR) How and when do we specify CIE OwR? How do we verify equipment meets the standards?

So What s Changed? Delegated regulation 157/2014: Describes how a DoP may be made available on a web site Free of charge to recipients of the product Link to a DoP by a unique product-type ID code Accessible for >10 years after placed on the market Site to be monitored to ensure access

How do Products and Systems comply? Product / Component Installation / System Legislation Construction Products Regulation (CPR) Regulatory Reform (Fire Safety) Order + other Standards Proof of Conformity EN 54 Series, EN 1155, EN 12094-1 CE marking, DoP, CoP, (CoC under the CPD) BS 5839-1, BS 5839-6, BS 5839-8, BS 5839-9 BS 5839-1 Commission Cert. BAFE SP203 & LPCB 1204 schemes

How do products show compliance? Fire alarm systems must comply with: Low Voltage Directive (for electrical safety) EMC directive (for reliability and coexistence with other equipment) Construction Product Regulations (for safety performance) Possibly other legislation such as ATEX Directive Compliance shown by CE mark plus: DoC for most Directives - Manufacturers can self declare conformity DoP + manufacturers documentation for CPR; Need 3 rd party approval Some equipment does not yet have an EN 54 standard Repeaters, video fire detectors, tactile alarm devices Need to consider if a repeater is essential for fire safety?

Selection of EN 54-2 OwR Options with Requirements Allows for variation in performance Flexibility in providing functions to meet different applications Functions required are determined by a fire risk assessment Function Option with Requirements EN 54-2 Clause Indications Fault signals from points 8.3 Alarm counter 7.13 Controls Delays to outputs 7.11 Outputs Fire alarm device(s) 7.8 Output to fire alarm routing equipment 7.9.1 Automatic fire protection equipment type A, B or C 7.10.1, 7.10.2, 7.10.3

Selection of OwR (Indications) Title OwR Application Additional notes Fault signals from points 8.3 Not in BS 5839-1 Maintenance information: No fault - device is connected & working Only available on addressable CIE Total loss of power 8.4 Alarm Counter 7.13 Not required in UK Not required in UK Indication for 1 hour when both the mains and the standby battery have failed (Auxiliary battery) Non-resettable counter of the total number of fire activations

Dependency on more than one alarm Also known as coincidence detection BS 5839-1 recommends this to reduce false alarms Type A: 7.12.1 Fire condition with two signals from one detector, (double knock) or Fire condition with two detectors in the same zone May reduce unwanted alarms from unoccupied premises Type B: 7.12.2 Similar to A but confirmation may come from a different zone Sometimes used in extinguishing systems Type C: 7.12.3 Fire signal may come from a MCP or a fire detector Used in occupied premises with a staff alarm

Other control functions Title OwR Application Additional notes Delays to outputs 7.11 Recommended in BS 5839-1 for false alarm reduction Similar to coincidence Type C Time delay after the first signal Occupied premises with a staff alarm Disablement of address points 9.5 Not in BS 5839-1 Only available on addressable CIE, offers increased control Test condition 10 Not in BS 5839-1 Test condition allows a FDAS to be tested zone by zone avoiding a full system alarm

Output signals Title OwR Application Additional notes Fire alarm device(s) Output to fire alarm routing equipment 7.8 7.9.1 Recommended in BS 5839-1 for life safety. Sometimes required for property protection Recommended in BS 5839-1 for property and residential care Includes both non addressable alarm circuits, or addressable devices on a loop Output to operate EN 54-21 device sending a signal to an ARC. MCP is recommended in BS 5839-1 Alarm routing equipment confirmation 7.9.2 Not required in the UK A signal on the CIE to confirm that the ARC has received the signal

Automatic fire protection equipment Interface with extinguishing system, fire doors, fire dampers, smoke curtains or lifts and HVAC Type A: 7.10.1 Output stays active while in fire and is not turned off when silenced May require multiple outputs for different systems Type B: 7.10.2 As type A but requires an indication of operation of the output Type C: 7.10.3 As type A but requires a confirmation signal from the equipment Monitoring of automatic fire protection: 7.10.4 Indication on the CIE of faults from the fire protection equipment

Other output signals Title OwR Application Additional notes Fault Warning routing equipment 8.9 Recommended in BS 5839-1 when standby duration is >72 hrs Fault signal from the CIE is sent to the ARC to inform of a fault, particularly a power fault Standardized I/O interface 11 Not required in the UK Required in some countries to interface to a fireman s panel

How do we show options on a DoP? Essential characteristics Perf* Article in EN 54-2 Operational reliability (when provided) Pass 12 (Product documentation to list OwR)** Fire alarm device(s) Pass 7.8 Fire alarm routing equipment (FAR) Pass 7.9.1 Confirmation signal from FAR NPD 7.9.2 Auto Fire Protection equip. type A Pass 7.10.1 Auto Fire Protection equip. type B Pass 7.10.2 Auto Fire Protection equip. type C NPD 7.10.3 Fault monitoring of FPE NPD 7.10.4 * NPD: No Performance Determined. Also used when an optional characteristic is not provided ** EN 54-2, 12.2.1: The manufacturer shall submit to the testing authority a description of the equipment, including a list of the optional functions with requirements of this Standard

How do we show options on a DoP? Essential characteristics Perf* Article in EN 54-2 Delay to outputs type C, E & G Pass 7.11.1 Able to switch delay to outputs off Pass 7.11.2 Dependency on >1 alarm type A Pass 7.12.1 Dependency on >1 alarm type B NPD 7.12.2 Dependency on >1 alarm type C NPD 7.12.3 Alarm Counter NPD 7.13 Fault signals from points Pass 8.3 Total loss of power supply NPD 8.4 Fault warning routing equipment NPD 8.9 Disablement of addressable points Pass 9.5 Test condition Pass 10 Standardised I/O interface NPD 11

What Guidance is available? Euralarm Guidance on EU Construction Products Regulation https://www.euralarm.org/press/publications/ FIA Guidance on EU Construction Products Regulation http://www.fia.uk.com/resourcelibrary/searchresults/?q=guidance+eu FIA Guidance for Specifiers of Control and Indicating Equipment http://www.fia.uk.com/resourcelibrary/searchresults/?q=guidance+for+specifiers

Construction Products Regulation Update Thank you Any questions?