McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016

Similar documents
McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

Air Cooled Scroll Compressor Condensing Unit

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017

REPLACEMENT PARTS LIST

PS9 SERIES - UPFLOW 1-STAGE NATURAL GAS FURNACE - 90%

REPLACEMENT PARTS LIST

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017

RP8.1Y (ERRATA 1) (202) 2 of 8

Replacement Parts List

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018

PT9 SERIES - UPFLOW 2-STAGE NATURAL GAS FURNACE - 90% (STYLE A)

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

VertiCool Aurora Engineering Guide

Replacement Parts List

KG 092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

KGA092 SHOWN READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

2 STAGE UPFLOW NATURAL GAS FURNACES (94+)

McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978

TGA/KGA024, 030, 036, 048, 060, 072, 090 (2, 2 1/2, 3, 4, 5, 6, and 7 1/2 TONS)

Product Data. Features/Benefits All in one package cooling efficiency, installation convenience and ease of accessibility allow for timesaving

GM9V SERIES - UPFLOW 2-STAGE VARIABLE SPEED NATURAL GAS FURNACE - 90% (STYLE A)

DESCRIPTION TECHNICAL GUIDE SINGLE PACKAGE GAS/ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS D(HE, HG) 036, 048 & YTG-A-0506

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

McQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016

2-STAGE UPFLOW/HORIZONTAL MID-EFFICIENCY NATURAL GAS FURNACES - (80%)

Daikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone. RCS Tons Vintage C Code 12= 1A, 2A. Valid for units built 06/2010 & Earlier

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

UPFLOW NATURAL GAS FURNACES - 90%

C13-Series Engineering Guide

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

FG9 - STYLES A AND B UPFLOW NATURAL GAS FURNACES (90%)

GM9T SERIES 2-STAGE (STYLE B) UPFLOW NATURAL GAS FURNACES - 90%

Wall Mounted Air Conditioners with Gas Heat Models AVGA

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

Product Data. Features/Benefits All in one package high cooling efficiency, installation convenience, ease of accessibility allow for timesaving

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

SUNLINE 2000 SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS DESCRIPTION FEATURES

technical guide Water-Cooled Self-Contained Units

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

LGA/LGC036, 042, 048, 060, 072 (3, 3-1/2, 4, 5, and 6 TONS) LGA/LGC090, 102, 120, 150, (7-1/2, 8-1/2, 10, and 12-1/2 TONS)

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

DFG-100-ES and DFG-200-ES

SPLIT-SYSTEM HEAT PUMPS 50 AND 60 HZ DESCRIPTION

REPLACEMENT PARTS MANUAL

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Effective february 9, 2015

Commercial High-Efficiency Condensing Units

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Advance Release September 2009

FL9M SERIES MODULATING CONDENSING UPFLOW NATURAL GAS FURNACES (STYLE A)

Effective october 14, 2014

GM9S SERIES UPFLOW CONDENSING NATURAL GAS FURNACES (STYLE J)

MARVAIR CLASSIC HEAT PUMPS MODELS AVP HP EXPLODED VIEW PARTS ID

RGE 13 A T - 1 A

REPLACEMENT PARTS LIST Dual Fuel Gas Heat Pump DF6SF Series & DF6SF "A" Series 15 SEER Models

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

Parts List. Stackable Crescent Cuber. Models KM-1601SAJ/3 KM-1601SWJ/3 KM-1601SRJ/3. hoshizakiamerica.com

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

bc14g combi oven serial numbers with iw/ix/iz/jg/jo

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

SUNLINE SERIES SINGLE PACKAGE AIR CONDITIONERS. INSTALLATION INSTRUCTION Supersedes: Nothing N3Y (394) MODELS D*SC360 & 480 INSPECTION

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

Transcription:

Replacement Parts List No. 057102700 Revision A 11/2016 McQuay Commercial Unitary Rooftop CUR 075-150 Vintage G Last Manufactured: 1996 To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

Contents Parts List Revison History... 3 Nomenclature Serial Number... 4 Model Number... 4 Model Number- Complete... 5 Electrical Legend... 6 Main Control Box...7-8 Electric Heat Control Box...9-13 Compressor... 14 Condenser Fan...15-17 Refrigeration Circuit, Heating Coils, and Filters... 18 Supply Air Fan...19-20 Gas Heat...21-22 Outside Air Damper... 23 Economizer Bottom Discharge... 24 Horizontal Discharge... 25 Cabinet Panels... 26 Field Installed Accessories Disconnect Switches... 27 Thermostats & Miscellaneous... 28 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 2

Parts List Revision History Revision Date Description A 11/16 Rebrand Daikin. Numerous changes. Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 3

Nomenclature Serial Number Until 1/95 5 Y A 00000 00 Plant Identification Number 1= Minneapolis 3= Faribault 5= Staunton 7= Auburn 9= Scottsboro Year Manufactured S= 1987 W= 1991 T= 1988 X= 1992 U= 1989 Y= 1993 V= 1990 Z= 1994 Engineering Revision Serial Number (Building Sequence) Month Manufactured A = January G = July B = February H = August C = March J = September D = April K = October E = May L = November F = June M = December Serial Number 1/95 and Later 7 5 A 00000 00 Plant Identification Number 1= Minneapolis 3= Faribault 5= Staunton 7= Auburn 9= Scottsboro Year Manufactured 5 = 1995 6 = 1996 Engineering Revision Serial Number (Building Sequence) Month Manufactured A = January G = July B = February H = August C = March J = September D = April K = October E = May L = November F = June M = December Model Number CUR 075 G T H Commercial Unitary Rooftop Nominal Capacity 075 = 7.5 Tons 085 = 8.5 Tons 100 = 10 Tons 125= 12.5 Tons 150= 15 Tons Design Vintage Voltage T = 460/60/3 F = 208-230/60/3 W = 575/60/3 Heat Type Y = Cooling Only H = Natural Gas (High Ht.) K = Natural Gas (High Ht./High Altitude) L = Natural Gas (Low Heat) J = Natural Gas (Low Ht./High Altitude) P = Propane Gas Z = Propane Gas (High Altitude) W = Hot Water Or Steam 2 thru 9 = Electric Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 4

Nomenclature Model Number Complete CUR 075G N21 T C B Y 11 2A Y Y A 1 Y 1 Y Y Y Y Y Y Y Y Code 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 Code 01: Unit Type CUR= Comercial Rooftop Code 02: Unit Size/Vintage 075G= 7.5 Tons Nominal Cooling 085G= 8.5 Tons Nominal Cooling 110G= 10 Tons Nominal Cooling 125G= 12.5 Tons Nominal Cooling 150G= 15 Tons Nominal Cooling Code 03: Type of Heat Selection Designature Unit Size YYY Cooling Only ALL N10 Natural Gas, 105MBH ALL N14 Natural Gas, 140MBH ALL N21 Natural Gas, 210MBH ALL N24 Natural Gas, 245MBH ALL N28 Natural Gas, 280MBH 125, 150 P10 Propane Gas, 105MBH ALL P14 Propane Gas, 140MBH ALL P21 Propane Gas, 210MBH ALL P24 Propane Gas, 245MBH ALL P28 Propane Gas, 280MBH 125, 150 E02 Electric, 10KW ALL E05 Electric, 20KW ALL E08 Electric, 30KW ALL E11 Electric, 40KW ALL E14 Electric, 50KW ALL E15 Electric, 60KW 125, 150 W02 2 Row Hot Water Coil ALL S01 1 Row Steam Coil ALL Code 04: Voltage F= 208/230/60/3 T= 460/60/3 W= 575/60/3 Code 05: Outside Air A= 0-25% Manual Damper C= 0-100% Economizer Code 06: Supply/Return Air Openings B= Bottom of Unit H= Horizontal Code 07: Brand Name Y= None Code 08: Evaporator/Condenser Fin Material 1 2 Condenser 1= Aluminum Fins 2= Copper Fins Code 09: Supply Fan Motor Horsepower 1A= Standard Motor 2A= Oversized Motor Code 10: Always= Y Code 11: Disconnect Switch 1= Non-Fused Y= None Code 12: Temperature Control A= Wall Thermostat Wiring C= Discharge Air Control Code 13: Capacity Control 1= 2-Step Capacity Reduction 3= 3-Step Capacity Reduction Code 14: Hot Gas Bypass A= Hot Gas Bypass Y= None Code 15: Filters 1= 2" Throwaway 4= 4" Throwaway Code 16: Power Exhaust Fan A= Power Exhaust with Standard HP Motor B= Same as "A" with R/A Tracking Damper Y= None Code 17: Power Return Fan 1= Standard HP Motor Y= None Codes 18: Return Air Fan 1= Firestat, Return Air Y= None Code 19: Safety Smoke Control Relays A= Safety Smoke Control Y= None Code 20: Power Saver Thermostat 1= Power Saver Thermostat Y= None Code 21: Pumpdown Control A= Pumpdown Control Y= None Code 22: Suction Line Filter 1= Suction Line Filter Y= None Code 23: Clogged Filter and Failure Relay Package A= Fan On, Cool On, Heat On B= Fan On, Cool On, Heat On & Clogged Filter Flag. C= Same as "B" with Cool Failure, Heat Failure Relay Pkg. Y= None Code 24: Agency Approval Code 25: Warranty Evaporator 1= Aluminum Fins 2= Copper Fins Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 5

Nomenclature Electrical Legend DESIGNATION DESCRIPTION STD. LOCATION DESIGNATION DESCRIPTION STD. LOCATION C1, 2, 3, 4 CAPACITORS FOR COND. MOTORS CONTROL BOX C5 CAPACITOR FOR VENTOR MOTOR HEAT SECTION CM1, 2, 3, 4 CONDENSER FAN MOTORS CONDENSER SECTION COMPR1-3 COMPRESSORS CONDENSER SECTION DM DAMPER MOTOR ECON/RETURN SECTION DS1 DISCONNECT SWITCH, MAIN CONTROL BOX DS3 DISCONNECT SWITCH, ELEC. HEAT HEAT SECTION F1 FUSE, CONTROL CIRCUIT CONTROL BOX F5, 6 FUSE, GAS HEAT CONTROL BOX FB8 FUSEBLOCK, POWER CONTROL CONTROL BOX FB30 FUSEBLOCK, POWER CONTROL HEAT SECTION FB31, 32, 33 FUSEBLOCK, ELECTRIC HEAT HEAT SECTION FRS FLAME RECTIFICATION SENSOR HEAT SECTION GRD GROUND CNTRL BOX, HEAT SECT. GV1 GAS VALVE, MAIN HEAT SECTION HL1, 2, 3 HI LIMITS, ELEC. HEAT, SECONDARY HEAT SECTION HL21, 22 HI LIMITS, GAS HEAT FAN SECTION HL23 HI LIMIT, GAS HEAT ROLLOUT HEAT SECTION HL31, 32 HI LIMITS, ELEC. HEAT, PRIMARY HEAT SECTION HP1, 2, 3 HI PRESSURE CONTROLS CONTROL BOX IGN IGNITION ELECTRODE HEAT SECTION LP1, 2, 3 LOW PRESSURE CONTROLS CONTROL BOX M1, 2, 3 CONTACTORS, COMPRESSOR CONTROL BOX M1, 2, 3 AUX. AUXILIARY CONTACTS CONTROL BOX M10 CONTACTOR, SUPPLY FAN CONTROL BOX M31, 32, 33 CONTACTORS, ELECTRIC HEAT HEAT SECTION M31-33 AUX. AUXILIARY CONTACTS HEAT SECTION MAT MIXED AIR SENSOR SUPPLY FAN SECTION MJ MECHANICAL JUMPERS CNTRL BOX & ECONO. SECT. OAE OUTSIDE AIR ENTHALPY ECONO/RETURN SECTION P1 PLUG FOR ECONOMIZER SUPPLY FAN SECTION P2 PLUG FOR HEAT CONTROL BOX P3 PLUG FOR ALARMS CONTROL BOX PB1 POWER BLOCK, MAIN CONTROL BOX PB3 POWERBLOCK, ELECTRIC HEAT HEAT SECTION PC1, 2, 3 PR. SWITCH, LOW AMBIENT CONTROL BOX PC5 PR. SWITCH, CLOGGED FILTER SUPPLY FAN SECTION PC6 PRESSURE SWITCH, FAN SUPPLY FAN SECTION PCB1 LOCAL/REMOTE STATUS BOARD CONTROL BOX R1, 2, 3 RELAYS, HIGH PRESSURE CONTROL BOX R9 RELAY, HEAT HEAT SECTION R10 RELAY, VENTILATION/SMOKE CONTROL BOX RAE RETURN AIR ENTHALPY ECONO/RETURN SECTION SAF SUPPLY AIR FAN MOTOR SUPPLY FAN SECTION T1 TRANSFORMER, MAIN CONTROL CONTROL BOX T3 TRANSFORMER, GAS HEAT CONTROL BOX TB1 TERMINAL BLOCK, 24V FIELD CONTROL BOX TB2 TERMINAL BLOCK, 24V FIELD SUPPLY FAN SECTION TC1 THERMOSTAT, FANTROL CONTROL BOX TC5 T'STAT, RETURN AIR FIRESTAT SUPPLY FAN SECTION TC6 THERMOSTAT, SUPPLY AIR FIRESTAT SUPPLY FAN SECTION TC7 THERMOSTAT, FREEZESTAT SUPPLY FAN SECTION TC15 THERMOSTAT, POWER SAVER HEAT SECTION TD1, 2, 3 TIME DELAYS, COMPR. LOCKOUT CONTROL SECTION TD9 TIME DELAY, HEAT HEAT SECTION VM1 FURNACE VENTOR MOTOR GAS HEAT SECTION VMS VENTOR MTR CENTRIFUGAL SWITCH GAS HEAT SECTION Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 6

Main Control Box LP3 HP3 R2 FB8 C2 HP2 C1 R3 PC3 LP2 PC2 LP1 PC1 TC1 R1 M3 M2 T1 HP1 M1 M10 PB1 R10 F5 T3 F6 TD1 TD3 TD2 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 7

Main Control Box Schem. NS = Not Shown R9 & TD9 - See Gas Heat section Description Unit Size Part Number 075 085 110 125 150 C1,2,3,4 Capacitor, Cond. Fan, 208-230V, 5MFD, 370V 2 2 2 2 4 049263701 C1,2,3,4 Capacitor, Cond. Fan, 460/575V, 7.5MFD, 370V 2 2 2 2 4 049263702 F5-6 Fuse, Gas Heat, 0.8A, 460V 2 2 2 2 2 049759803 F5-6 Fuse, Gas Heat, 0.5A, 575V 2 2 2 2 2 049759802 FB8 Fuseblock, 208/230V, 2P 30A 1 1 023780202 FH5,6 (N/S) Fuseholder, 460/575V, 20A 2 2 2 2 2 047354105 HP1,2,3 Switch, High Pressure Control 2 2 2 3 3 047356117 LP1,2,3 Switch, Low Pressure Control w/o Low Ambient Start 2 2 2 3 3 047356113 LP1,2,3 Switch, Low Pressure Control with Low Ambient Start 2 2 2 3 3 047356114 M1,2 Contactor, Compressor, 3P, 25FLA 2 2 2 041769603 M1,2,3 Contactor, Compressor with SPDT Aux, 3P, 25FLA 3 3 049764703 M10 Contactor, Supply/Return Air Fan Motor, 3P, 20FLA 1 1 1 1 1 041769603 PB1 Power Block, Main, 3P 1 1 1 1 1 049125601 PC1,2,3 Switch, Cond. Fan Low Ambient Pressure Control 2 2 2 3 3 047356115 PCB1 (N/S) PC Board, Local/Remote Status 1 1 1 1 1 049766401 N/S Support For PC Board 1 1 1 1 1 055466801 R1,2,3 Relay, High Pressure, 1P, 24V 2 2 2 3 3 043755800 R10 Relay, Ventilation/Smoke, 4PDT, 24V 1 1 1 1 1 049751601 T1 Transformer, 75VA, 208/230V 1 1 1 1 1 046738110 T1 Transformer, 75VA, 460V 1 1 1 1 1 046738111 T1 Transformer, 75VA, 575V 1 1 1 1 1 046738112 T3 Transformer, 100V Gas Heat, 460/230V 1 1 1 1 1 049760201 T3 Transformer, 100V Gas Heat, 575/230V 1 1 1 1 1 049760202 TC1 Thermostat, Fantrol, SPST 1 1 1 1 1 049750901 TD1,2,3 Time Delay Relay, 3 Minute, SPST 2 2 2 3 3 028210127 N/S Hi-Low Manifold 2 2 2 3 3 049753801 N/S Fuse, 208/230V, 15A (On FB8) 2 2 025860505 N/S Spring, R10 Relay 1 1 1 1 1 049751702 N/S Jumper Board, R10 Socket 1 1 1 1 1 049751703 N/S Socket, R10 Relay 1 1 1 1 1 049751701 N/S Clamp, Capacitor 2 2 2 2 2 040971307 Optional Unit Controls (Mount in Supply Fan Section) TC5 (N/S) Thermostat, Return Air Firestat, 125 F 1 1 1 1 1 047938802 TC6 (N/S) Thermostat, Supply Air Firestat, Heat Units 240 F 1 1 1 1 1 047938803 TC6 (N/S) Thermostat, Supply Air Firestat, Cooling Units Only 1 1 1 1 1 047938802 TC7 (N/S) Thermostat, Freezestat, SPST 1 1 1 1 1 049754001 PC5 (N/S) Control, Clogged Filter Pressure 1 1 1 1 1 049762702 PC6 (N/S) Control, Fan Switch Pressure 1 1 1 1 1 049755501 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 8

Electric Heat Control Box HL31 HTR HL32 M31 M32 M33 HL1 HL2 HL3 R9 FB31 FB32 FB33 FB30 TC15 PB3 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 9

Electric Heat Control Box Schem. AR= As Required Description KW Voltage Unit Size Part Number 075 085 110 125 150 FB30 Fuseblock, 3P, 60A 250V ALL 208/230V 1 1 023780209 FB30 Fuseblock, 3P, 30A 600V ALL 460/575V 1 1 023780205 FB30 Fuseblock, 3P, 100A 250V ALL 208/230V 1 1 1 023780213 FB30 Fuseblock, 3P, 60A 600V ALL 460V 1 1 1 023780210 FB30 Fuseblock, 3P, 30A 600V ALL 575V 1 1 023780205 FB30 Fuseblock, 3P, 60A 600V ALL 575V 1 023780210 FB31 Fuseblock, 3P, 30A 250V 10 208/230V 1 1 1 1 1 023780204 FB31 Fuseblock, 3P, 30A 600V 10 460/575V 1 1 1 1 1 023780205 FB31 Fuseblock, 3P, 30A 250V 20 208/230V 1 1 1 1 1 023780209 FB31 Fuseblock, 3P, 30A 600V 20 460/575V 1 1 1 1 1 023780205 FB31 Fuseblock, 3P, 60A 250V 30 208/230V 1 1 1 1 1 023780209 FB31 Fuseblock, 3P, 60A 600V 30 460/575V 1 1 1 1 1 023780210 FB31 Fuseblock, 3P, 60A 250V 40 208/230V 1 1 1 1 1 023780209 FB31 Fuseblock, 3P, 60A 600V 40 460/575V 1 1 1 1 1 023780210 FB31 Fuseblock, 3P, 60A 250V 50 208/230V 1 1 1 1 1 023780209 FB31 Fuseblock, 3P, 60A 600V 50 460/575V 1 1 1 1 1 023780210 FB31 Fuseblock, 3P, 60A 250V 60 208/230V 1 1 1 1 1 023780209 FB31 Fuseblock, 3P, 60A 600V 60 460/575V 1 1 1 1 1 023780210 FB32 Fuseblock, 3P, 30A 250V 30 208/230V 1 1 1 1 1 023780204 FB32 Fuseblock, 3P, 60A 250V 40 208/230V 1 1 1 1 1 023780209 FB32 Fuseblock, 3P, 60A 250V 50 208/230V 1 1 1 1 1 023780209 FB32 Fuseblock, 3P, 60A 600V 50 460/575V 1 1 1 1 1 023780205 FB32 Fuseblock, 3P, 60A 250V 60 208/230V 1 1 1 1 1 023780209 FB32 Fuseblock, 3P, 30A 600V 60 460/575V 1 1 1 1 1 023780205 FB33 Fuseblock, 3P, 30A 250V 50 208/230V 3 3 3 3 3 023780204 FB33 Fuseblock, 3P, 60A 250V 60 208/230V 1 1 1 1 1 023780209 HL1-3 Cutout, High Limit, Manual Reset, DPST 210 F AR AR AR AR AR 065496201 HL31 Cutout, High Limit, Auto Reset, SPST 110/140 F 1 1 1 1 1 065496101 HL32 Cutout, High Limit, Auto Reset, SPST 110/140 F, 20-60 KW 1 1 1 1 1 065496101 Continued on next page. Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 10

Schem. Electric Heat Control Box Continued Description KW Voltage Unit Size Part Number 075 085 110 125 150 HTR Heater with High Limit Cutouts 10 208/230V 1 1 1 1 1 055412702 HTR Heater with High Limit Cutouts 10 460V 1 1 1 1 1 055412703 HTR Heater with High Limit Cutouts 10 575V 1 1 1 1 1 055412704 HTR Heater with High Limit Cutouts 20 208/230V 1 1 1 1 1 055412705 HTR Heater with High Limit Cutouts 20 460V 1 1 1 1 1 055412706 HTR Heater with High Limit Cutouts 20 575V 1 1 1 1 1 055412707 HTR Heater with High Limit Cutouts 30 208/230V 1 1 1 1 1 055412708 HTR Heater with High Limit Cutouts 30 460V 1 1 1 1 1 055412709 HTR Heater with High Limit Cutouts 30 575V 1 1 1 1 1 055412710 HTR Heater with High Limit Cutouts 40 208/230V 1 1 1 1 1 055412711 HTR Heater with High Limit Cutouts 40 460V 1 1 1 1 1 055412712 HTR Heater with High Limit Cutouts 40 575V 1 1 1 1 1 055412713 HTR Heater with High Limit Cutouts 50 208/230V 1 1 1 1 1 055412714 HTR Heater with High Limit Cutouts 50 460V 1 1 1 1 1 055412715 HTR Heater with High Limit Cutouts 50 575V 1 1 1 1 1 055412716 HTR Heater with High Limit Cutouts 60 208/230V 1 1 1 1 1 055412717 HTR Heater with High Limit Cutouts 60 460V 1 1 1 1 1 055412718 HTR Heater with High Limit Cutouts 60 575V 1 1 1 1 1 055412719 M31 Contactor with Aux., 3P 40FLA 10 ALL 1 1 1 1 1 049764602 M31 Contactor with Aux., 3P 40FLA 20 ALL 1 1 1 1 1 049764602 M31 Contactor with Aux., 3P 40FLA 30 ALL 1 1 1 1 1 049764602 M31 Contactor with Aux., 3P 40FLA 40 ALL 1 1 1 1 1 049764602 M31 Contactor with Aux., 3P 40FLA 50 ALL 1 1 1 1 1 049764602 M31 Contactor with Aux., 3P 40FLA 60 ALL 1 1 1 1 1 049764602 M32 Contactor w/o Aux., 3P 40FLA 20 ALL 1 1 1 1 1 047136402 M32 Contactor w/o Aux., 3P 40FLA 30 ALL 1 1 1 1 1 047136402 M32 Contactor w/o Aux., 3P 40FLA 40 ALL 1 1 1 1 1 047136402 M32 Contactor with Aux., 3P 40FLA 50 208/230V 1 1 1 1 1 049764602 M32 Contactor w/o Aux., 3P 40FLA 50 460/575V 1 1 1 1 1 047136402 M32 Contactor with Aux., 3P 40FLA 60 208/230V 1 1 1 1 1 049764602 M32 Contactor w/o Aux., 3P 40FLA 60 460/575V 1 1 1 1 1 047136402 M33 Contactor with Aux., 3P 40FLA 50 208/230V 1 1 1 1 1 049764602 M33 Contactor with Aux., 3P 40FLA 60 208/230V 1 1 1 1 1 049764602 PB3 Power Terminal Block, 3P 175A 10-40 208/230V 1 1 1 1 1 030372705 PB3 Power Terminal Block, 3P 175A 10-60 460/575V 1 1 1 1 1 030372705 PB3 Power Terminal Block, 3P 335A 50-60 208/230V 1 1 1 1 1 030372716 Continued on next page. Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 11

Schem. Description KW Voltage Unit Size Part Number 075 085 110 125 150 R9 Heat Relay, SPDT 10 ALL 1 1 1 1 1 047356507 R9 Heat Relay, SPDT 20 ALL 1 1 1 1 1 047356507 R9 Heat Relay, SPDT 30 ALL 1 1 1 1 1 047356507 R9 Heat Relay, SPDT 40 ALL 1 1 1 1 1 047356507 R9 Heat Relay, SPDT 50 ALL 1 1 1 1 1 047356507 R9 Heat Relay, SPDT 60 ALL 1 1 1 1 1 047356507 TC15 Thermostat, Power Saver 20-60 ALL 1 1 1 1 1 049754002 N/S Fuse, 30A 250V 10 208/230V 3 3 3 3 3 025860509 N/S Fuse, 15A 600V 10 460/575V 3 3 3 3 3 025860405 N/S Fuse, 60A 250V 20 208/230V 3 3 3 3 3 025860514 N/S Fuse, 45A 600V 20 460V 3 3 3 3 3 025860409 N/S Fuse, 25A 600V 20 575V 3 3 3 3 3 025860408 N/S Fuse, 60A 250V (FB31) 30 208/230V 3 3 3 3 3 025860514 N/S Fuse, 45A 600V (FB31) 30 460V 3 3 3 3 3 025860412 N/S Fuse, 35A 600V (FB31) 30 575V 3 3 3 3 3 025860410 N/S Fuse, 30A 250V (FB32) 30 208/230V 3 3 3 3 3 025860909 N/S Fuse, 60A 250V (FB31 & FB32) 40 208/230V 6 6 6 6 6 025860514 N/S Fuse, 60A 600V (FB31) 40 460V 3 3 3 3 3 025860414 N/S Fuse, 50A 600V (FB31) 40 575V 3 3 3 3 3 025860413 N/S Fuse, 60A 250V (FB31 & FB32) 50 208/230V 6 6 6 6 6 025860514 N/S Fuse, 30A 600V (FB31) 50 460V 3 3 3 3 3 025860409 N/S Fuse, 25A 600V (FB31) 50 575V 3 3 3 3 3 025860408 N/S Fuse, 45A 600V (FB32) 50 460V 3 3 3 3 3 025860412 N/S Fuse, 35A 600V (FB32) 50 575V 3 3 3 3 3 023860410 N/S Fuse, 30A 250V (FB33) 50 208/230V 3 3 3 3 3 025860509 N/S Fuse, 60A 250V (FB31, FB32 & FB33) 60 208/230V 9 9 9 9 9 025860514 N/S Fuse, 60A 600V (FB31) 60 460V 3 3 3 3 3 025860414 N/S Fuse, 50A 600V (FB31) 60 575V 3 3 3 3 3 025860413 N/S Fuse, 30A 600V (FB32) 60 460V 3 3 3 3 3 025860409 N/S Fuse, 25A 600V (FB32) 60 575V 3 3 3 3 3 025860408 NS = Not Shown Electric Heat Control Box Continued Continued on next page. Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 12

Schem. Electric Heat Control Box Continued Description Voltage Unit Size Part Number 075 085 110 125 150 N/S Fuse, 50A 250V 208/230V 3 25860513 N/S Fuse, 25A 600V 460V 3 25860408 N/S Fuse, 20A 600V 575V 3 25860407 N/S Fuse, 60A 250V 208/230V 3 25860514 N/S Fuse, 30A 600V 460V 3 25860409 N/S Fuse, 25A 600V 575V 3 25860408 N/S Fuse, 70A 250V 208/230V 3 25860515 N/S Fuse, 35A 600V 460V 3 25860410 N/S Fuse, 30A 600V 575V 3 25860409 N/S Fuse, 80A 250V 208/230V 3 25860516 N/S Fuse, 40A 600V 460V 3 25860411 N/S Fuse, 30A 600V 575V 3 25860409 N/S Fuse, 100A 250V 208/230V 3 25860518 N/S Fuse, 50A 600V 460V 3 25860413 N/S Fuse, 40A 600V 575V 3 25860411 NS = Not Shown Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 13

Compressor 228 11 227 229 No. Description Voltage Unit Size 075 085 110 125 150 Part Number 11 Compressor, 3.8HP 208/230/60/3 2 056514804 11 Compressor, 3.8HP 460V/60/3 2 056514805 11 Compressor, 3.8HP 380-415/50/3 2 056514805 11 Compressor, 3.8HP 575/60/3 2 056514806 11 Compressor, 4HP 208/230/60/3 2 3 056514807 11 Compressor, 4HP 460V/60/3 2 3 056514808 11 Compressor, 4HP 380-415/50/3 2 3 056514808 11 Compressor, 4HP 575/60/3 2 3 056514809 11 Compressor, 5HP 208/230/60/3 2 3 056514801 11 Compressor, 5HP 460V/60/3 2 3 056514802 11 Compressor, 5HP 380-415/50/3 2 3 056514802 11 Compressor, 5HP 575/60/3 2 3 056514803 227 Grommet 8 8 8 12 12 049121002 228 Compressor, Shoulder Belt 8 8 8 12 12 049121801 229 Base, Compressor 2 2 2 3 3 055185804 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 14

Condenser Fan CUR 075G, 085G 185 192 195 193 187 186 191 194 188 190 193 191 192 200 182 CUR 110G 193 192 195 182 187 186 191 194 185 188 190 191 192 193 200 183 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 15

CUR125G Condenser Fan Continued 182 187 185 192 195 186 191 183 194 184 188 190 191 192 201 193 200 CUR 150G 182 197 185 192 195 186 189 191 183 194 187 188 190 191 192 193 200 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 16

Condenser Fan Continued No. 182 183 Description Unit Size 075 085 110 125 150 Part Number Fan Panel 1 1 055200701 Fan Panel 1 048968401 Fan Panel 1 071807101 Fan Panel 1 056514904 Coil Channel 1 1 048967701 Coil Channel 2 056520501 184 Venturi Panel 1 071338701 185 Condenser Motor Mount 2 2 2 2 4 049121501 186 187 1/2 HP TEFC - Condenser Motor - 208-230/60/1 2 2 2 2 4 049122100 1/2 HP TEFC - Condenser Motor - 460/60/1 2 2 2 2 4 049122200 1/2 HP TEFC - Condenser Motor - 575/60/1 2 2 2 2 4 049755800 Impeller, 24" O.D. 2 2 2 2 049121701 Impeller, 22" O.D. 4 056517801 188 Washer 8 8 8 8 16 035043428 189 Condenser Support 1 056523801 190 Screw, 5/16 x 1" 8 8 8 8 16 048878113 191 Washer, 5/16" 10 10 10 10 20 040500307 192 Locknut, 5/16" 10 10 10 10 20 040500104 193 Tapping Screw, #10 x1/2" 13 13 17 57 28 038265000 194 Screw, 5/16 x 1-1/4" 2 2 2 2 4 048878114 195 Tapping Screw, #10 x 3/8" 2 2 2 2 4 038990802 197 Screw, 1/4 x 1/2" 5 046093807 200 Condenser Bracket 2 2 2 1 2 071938601 201 Condenser Bracket 2 072196401 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 17

Refrigeration Circuit, Heating Coils, and Filters Unit Size Part No. Description 075 085 110 125 150 Number Evaporator Coil Assembly, Aluminum Fins 1 1 055194001 N/S Evaporator Coil Assembly, Aluminum Fins 1 055194005 Evaporator Coil Assembly, Aluminum Fins 1 1 056518901 N/S Expansion Valve, 4 Ton Capacity 2 2 2 3 3 024029619 N/S Condenser Coil, Aluminum Fins (Single) 1 1 055190002 N/S Condenser Coil, Aluminum Fins (Top & Bottom) 2 055190004 N/S Condenser Coil, Aluminum Fins, Single Circuit (Top) 1 055190003 N/S Condenser Coil, Aluminum Fins, Two Circuit (Bottom) 1 055190002 N/S Condenser Coil, Aluminum Fins (ALL) 3 056516901 N/S Guard Panel, Condenser Coil 2 2 055461601 Guard Panel, Condenser Coil 2 2 2 055461602 N/S Pressure Regulating Bypass Valve, Hot Gas 1 1 1 1 1 018172300 N/S Liquid Line Filter Drier AR AR AR AR AR 4FDX4883 N/S Hot Water Coil 1 1 055419701 Hot Water Coil 1 1 1 055419801 N/S Steam Coil 1 1 055419901 Steam Coil 1 1 1 055420001 N/S Filter - 2 X 25 X 25, Standard 3 3 034910300 N/S Pleated Filter - 2 X 25 X 25, Optional 3 3 031298007 N/S Filter - 2 X 20 X 25, Standard (Qty= 3 Each Per Unit) 3 3 3 000016000 N/S Filter - 2 X 16 X 25, Standard (Qty= 3 Each Per Unit) 3 3 3 000016100 N/S Pleated Filter - 2 X 20 X 25, Optional (Qty= 3 Each Per Unit) 3 3 3 031298004 N/S Pleated Filter - 2 X 16 X 25, Optional (Qty= 3 Each Per Unit) 3 3 3 031298002 NS = Not Shown AR = As Required For phenolic coated Evaporator and Condenser coils, please contact Daikin. Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 18

Supply Air Fan 156 155 003 004 002 170 005 160 153 175 153 154 152 180 754 753 755 185 159 752 751 147 145 No. 002 003 004 005 145 Description Unit Size 075 085 110 125 150 Part Number Plate, Blower Side, RH 2 2 055196402 Plate, Blower Side, RH 2 2 2 048968502 Plate, Blower Side, LH 2 2 055196401 Plate, Blower Side, LH 2 2 2 048968501 Wrap, Blower 2 2 055196501 Wrap, Blower 2 2 2 055196502 Wheel, Fan 2 2 049121601 Wheel, Fan 2 2 2 049121602 Support, Motor 1 1 055200201 Support, Motor 1 1 1 048972401 147 Base, Motor Mount 1 1 1 1 1 055186901 152 Shaft, Evaporator Fan 1 1 055197601 Shaft, Evaporator Fan 1 1 1 048972301 153 Key, 4 X 4.5" 2 2 2 2 2 023221307 154 Key, 4 X 2" 1 1 1 1 1 023221310 155 Ball Bearing, Self Aligning 2 2 000829904 Ball Bearing, Self Aligning 2 2 2 000829907 156 Mounting Bracket, Bearing 2 2 2 2 2 049121401 159 Mixed Air Sensor Thermostat (MAT) 1 1 1 1 1 049754102 Continued on next page. Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 19

Supply Air Fan Continued No. Description * For HL23, see Gas Heat section Unit Size 075 085 110 125 150 Part Number 160 High Limit, Auto Reset (HL21 Heat Units Only*) 1 1 1 1 1 049756401 170 Rev. Air Flow High Limit, Manual Reset (HL22 Heat Units Only*) 1 1 1 1 1 049756403 175 180 Drain Hose 1 1 049121901 Drain Hose 1 1 1 049121902 Motor Adjustment Strap 1 1 055200301 Motor Adjustment Strap 1 1 1 071134701 185 Drain Pan 1 1 1 1 1 055402001 751 Motor, Standard, 1HP, ODP, 208/230/460V 1 049752800 751 Motor, Standard, 1HP, ODP, 575V 1 049752900 751 Motor, Standard, 1.5HP, ODP, 208/230/460V 1 049753000 751 Motor, Standard, 1.5HP, ODP, 575V 1 049753100 751 Motor, Standard, 2HP, ODP, 208/230/460V 1 049753200 751 Motor, Standard, 2HP, ODP, 575V 1 049753300 751 Motor, Standard, 3HP, ODP, 208/230/460V 1 1 049753400 751 Motor, Standard, 3HP, ODP, 575V 1 1 049753500 751 Motor, Oversize, 1.5HP, ODP, 208/230/460V 1 049753000 751 Motor, Oversize, 1.5HP, ODP, 575V 1 049753100 751 Motor, Oversize, 2HP, ODP, 208/230/460V 1 049753200 751 Motor, Oversize, 2HP, ODP, 575V 1 049753300 751 Motor, Oversize, 3HP, ODP, 208/230/460V 1 049753400 751 Motor, Oversize, 3HP, ODP, 575V 1 049753500 751 Motor, Oversize, 5HP, ODP, 208/230/460V 1 1 049753600 751 Motor, Oversize, 5HP, ODP, 575V 1 1 049753700 752 752 753 753 754 754 Motor Pulley, Std Motor, 1 Groove, 3.80" PD, M Bore 1 1 029225400 Motor Pulley, Std Motor, 1 Groove, 4.40" PD, O Bore 1 1 000728900 Motor Pulley, Std Motor, 1 Groove, 3.80" PD, O Bore 1 031310600 Motor Pulley, Oversize Motor, 1 Groove, 3.80" PD, M Bore 1 029225400 Motor Pulley, Oversize Motor, 1 Groove, 4.40" PD, O Bore 1 1 000728900 Motor Pulley, Oversize Motor, 2 Groove, 4.40" PD, 1.125 Bore 1 1 000607600 Blower Pulley, Std Motor, 1 Groove, 6.50" PD, 1" Bore 1 000536200 Blower Pulley, Std Motor, 1 Groove, 5.50" PD 1" Bore 1 000097100 Blower Pulley, Std Motor, 1 Groove, 6.20" PD 1 000541400 Blower Pulley, Std Motor, 1 Groove, 6.50" PD 1 1 000573800 Blower Pulley, Oversize Motor, 1 Groove, 5.50" PD, 1" Bore 1 000097100 Blower Pulley, Oversize Motor, 1 Groove, 5.70", PD, O Bore 1 000097000 Blower Pulley, Oversize Motor, 1 Groove, 6.20" PD 1 000541400 Blower Pulley, Oversize Motor, 2 Groove, 5.50" PD 1 020062100 Blower Pulley, Oversize Motor, 2 Groove, 6.00" PD 1 019291400 Belt, Std Motor 1 1 1 1 000365500 Belt, Std Motor 1 030183400 Belt, Oversize Motor 1 1 2 2 030183400 Belt, Oversize Motor 1 000365500 755 Bushing, Blower Pulley, 1.188" Bore, Std. & Oversize Motor 1 1 1 000804400 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 20

Gas Heat 2 23 6 22 21 3 37 30 No. Description Unit Size 075 085 110 125 150 Part Number 2 Heat Exchanger, 105MBH 1 1 048995701 2 Heat Exchanger, 105MBH 1 1 1 048995720 2 Heat Exchanger, 140MBH 1 1 048995705 2 Heat Exchanger, 140MBH 1 1 1 048995725 2 Heat Exchanger, 210MBH 1 1 048995710 2 Heat Exchanger, 210MBH 1 1 1 048995730 2 Heat Exchanger, 245MBH 1 1 048995715 2 Heat Exchanger, 245MBH 1 1 1 048995735 2 Heat Exchanger, 280MBH 1 1 048995740 3 Turbulator, 105MBH 3 3 3 3 3 048966501 3 Turbulator, 140MBH 4 4 4 4 4 048966501 3 Turbulator, 210MBH 6 6 6 6 6 048966501 3 Turbulator, 245MBH 7 7 7 7 7 048966501 3 Turbulator, 280MBH 8 8 048966501 6 Furnace Ventor Motor, 1/16HP, 105-245MBH 1 1 1 1 1 049757001 Furnace Ventor Motor, 1/12HP, 280MBH 1 1 049757002 Continued on next page. Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 21

N/S = Not Shown * For HL21 & HL22, see Supply Air Fan section Gas Heat Continued Unit Size Part No. Description 075 085 110 125 150 Number 21 Relay, Time Delay, 24V (TD9) 1 1 1 1 1 049756901 22 Relay, Ventor Motor, DPST, 24V (R9) 1 1 1 1 1 047356506 23 Rollout Temperature Limit (HL23*) 1 1 1 1 1 049756402 30 Ignition Control 1 1 1 1 1 049751001 37 Igniter Cable, 11", 210-280MBH 1 1 1 1 1 055434301 Igniter Cable, 15", 105-140MBH 1 1 1 1 1 055434302 Manifold, 105-140MBH 1 1 1 049756501 N/S Manifold, 210-245MBH 1 1 1 049756502 Manifold, 105-280MBH 1 1 1 049756503 N/S Gas Valve, Natural, 105-140MBH 1 1 1 1 1 049751101 Gas Valve, Natural, 210-280 MBH 1 1 1 1 1 049751102 N/S Gas Valve, Propane, 105-140 MBH 1 1 1 1 1 049751103 Gas Valve, Propane, 210-280 MBH 1 1 1 1 1 049751104 Burner Gun, 105MBH 3 3 3 3 3 049755901 Burner Gun, 140MBH 4 4 4 4 4 049755901 N/S Burner Gun, 210MBH 6 6 6 6 6 049755901 Burner Gun, 245MBH 7 7 7 7 7 049755901 Burner Gun, 280MBH 8 8 8 8 8 049755901 Main Orifice, Propane, 105 MBH 3 3 3 3 3 055193202 Main Orifice, Propane, 140 MBH 4 4 4 4 4 055193202 N/S Main Orifice, Propane, 210 MBH 6 6 6 6 6 055193202 Main Orifice, Propane, 245 MBH 7 7 7 7 7 055193202 Main Orifice, Propane, 280 MBH 8 8 8 8 8 055193202 N/S Orifice, Natural, 105-140 MBH 1 1 1 1 1 049756603 Orifice, Natural, 210-280 MBH 1 1 1 1 1 049756601 N/S Orifice, Propane, 105-140 MBH 1 1 1 1 1 049756604 Orifice, Propane, 210-280 MBH 1 1 1 1 1 049756602 Burner Zip Tube, 105-140 MBH (Carryover Tube) 1 1 1 1 1 049756001 N/S Burner Zip Tube, 210-245 MBH (Carryover Tube) 1 1 1 1 1 049756002 Burner Zip Tube, 280 MBH (Carryover Tube) 1 1 049756003 N/S Burner Sensor 1 1 1 1 1 049756101 N/S Burner Igniter 1 1 1 1 1 049755601 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 22

Outside Air Damper 364 397 4 2 363 382 15 369 19 22 24 No. Description Unit Size 075 085 110 125 150 Part Number 2 Blade, Damper 12 12 12 18 18 048962301 4 Seal, Damper Bearing 8 8 8 12 12 049121101 15 Linkage, Damper, 20.16" 4 4 4 048962601 Linkage, Damper, 31.80" 4 4 048969801 19 Bearing, Sleeve 24 24 24 36 36 047138507 22 Actuator, Motor 1 1 1 1 1 049750502 24 Linkage, 2 Position Motor 1 1 1 1 1 055435001 363 Shaft -.31 X 73.26 1 1 1 1 1 055435101 364 Linkage, Fresh Air 1 1 1 1 1 048978201 369 Rod, Linkage 1 1 1 055435201 Rod, Linkage 1 1 055435202 382 Bearing, Sleeve 1 1 1 1 1 047138507 397 Connector, Damper Swivel 1 1 1 1 1 071273101 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 23

Economizer - Bottom Discharge 23 39 18 38 22 13 12 10 15 4 18 15 19 2 14 10 4 No. Description Unit Size 075 085 110 125 150 Part Number 2 Blade, Damper 4 4 5 5 5 048962302 4 Seal, Damper Bearing 4 4 4 4 4 049121101 10 Channel, Economizer 2 2 048963201 Channel, Economizer 2 2 2 048970101 12 Motor Mount 1 1 1 1 1 048963301 13 Motor Support 1 1 1 054434901 14 Panel, Blockoff 1 1 1 048977501 15 18 Linkage, Economizer Blade - 4 Hole 2 2 048963401 Linkage, Economizer Blade - 5 Hole 2 2 2 048970201 Linkage, Return Air - Fresh Air 2 2 055434501 Linkage, Return Air - Fresh Air 2 2 2 055434801 19 Bearing, Sleeve 12 12 12 12 12 047138507 22 Actuator, Proportional Motor 1 1 1 1 1 049750501 23 Control, Logic 1 1 1 1 1 049120901 38 Linkage, Damper Motor 1 1 1 1 1 055435901 39 Linkage, Economizer Rod 2 2 2 2 2 055434601 N/S Relief Damper Assy 1 1 055439201 Relief Damper Assy 1 1 1 055439202 N/S Outside Air or Return Air Enthalpy Control AR AR AR AR AR 049262202 N/S Bracket, Enthalpy Support AR AR AR AR AR 048981701 N/S N/S N/S = Not Shown AR = As Required Rainhood Top 2 2 055459101 Rainhood Top 2 2 2 055459301 Rainhood Side 4 4 055459201 Rainhood Side 4 4 4 055459401 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 24

Economizer - Horizontal Discharge 14 42 44 23 22 45 43 2 40 41 Unit Size Part No. Description 075 085 110 125 150 Number 2 Blade, Damper 4 4 6 6 6 048962302 14 Panel, Blockoff 1 1 048981401 Panel, Blockoff 1 1 1 048981301 22 Actuator, Proportional Motor 1 1 1 1 1 049750501 23 Control, Logic 1 1 1 1 1 049120901 40 Outside Air or Return Air Enthalpy Control AR AR AR AR AR 049262202 41 Bracket, Enthalpy Support AR AR AR AR AR 048981701 42 Damper Connector, Swivel 2 2 2 2 2 071273101 43 Damper Butterfly Clip 2 2 2 2 2 055433901 44 Linkage Rod 1 1 1 1 1 055435201 45 Moisture Shield 1 1 1 1 1 055459901 N/S Seal, Damper Bearing 4 4 4 4 4 049121101 N/S Channel, Economizer 2 2 048963201 Channel, Economizer 2 2 2 048981201 N/S Linkage, Economizer Blade - 4 Hole 2 2 048963401 Linkage, Economizer Blade - 6 Hole 2 2 2 048978801 N/S Bearing, Sleeve 8 8 12 12 12 047138507 N/S Linkage 1 1 1 1 1 048978201 N/S Rainhood Top 2 2 055459101 Rainhood Top 2 2 2 055459301 N/S Rainhood Side 4 4 055459201 Rainhood Side 4 4 4 055459401 N/S = Not Shown AR = As Required Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 25

Cabinet Panels 460 458 455 457 453 459 452 454 461 10 11 453 456 462 No. 10 11 Description Unit Size 075 085 110 125 150 Part Number Fresh Air Back Panel, Louvered, LH 1 1 055187001 Fresh Air Back Panel, Louvered, LH 1 1 1 048969101 Fresh Air Back Panel, Louvered, RH 1 1 055187002 Fresh Air Back Panel, Louvered, RH 1 1 1 048969102 452 Evaporator Panel Assembly 1 1 1 1 1 055400205 453 454 455 456 457 458 459 460 461 Blower / Filter Access Panel 2 2 055400207 Blower / Filter Access Panel 2 2 2 055400211 Back Access Panel (Units Without Relief Damper) 1 1 055400208 Back Acces Panel (Units Without Relief Damper) 1 1 1 055400212 Back Access Panel, Louvered (Units With Relief Damper) 1 1 055400209 Back Access Panel, Louvered (Units With Relief Damper) 1 1 1 055400213 Access Panel 1 1 055400206 Access Panel 1 1 1 055400210 Access Panel, Hydronic & Cooling Only Units 1 1 055400206 Access Panel, Hydronic & Cooling Only Units 1 1 1 055400210 Access Panel, Gas Heat Units 1 1 055425001 Access Panel, Gas Heat Units 1 1 1 055425002 Access Panel - Upper, Electric Heat Units (Also See #462) 1 1 055415201 Access Panel - Upper, Electric Heat Units (Also See #462) 1 1 1 055415301 Condenser Top Panel, Louvered 1 1 055185601 Condenser Top Panel, Wire 1 1 1 056527101 Front Compressor Panel 1 1 055187401 Front Compressor Panel 1 1 1 048971201 Front Control Box Panel 1 1 055187201 Front Compressor Panel 1 1 1 048971101 Compressor Access Panel 1 1 055188001 Compressor Access Panel 1 1 1 048971401 Control Box Access Panel 1 1 055188201 Control Box Access Panel 1 1 1 048971501 462 Access Panel - Lower, Electric Heat Units Only 1 1 1 1 1 055416202 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 26

Field Installed Accessories - Disconnect Switches No. Description Gas Heat & Cooling Only Units Voltage Unit Size 075 085 110 125 150 Part Number DS1 Disconnect Switch - 3P, 80A 208/230V 1 1 1 1 049750702 DS1 Disconnect Switch - 3P, 100A 208/230V 1 049750703 DS1 Disconnect Switch - 3P, 30A 460V 1 1 049750701 DS1 Disconnect Switch - 3P, 80A 460V 1 1 1 049750702 DS1 Disconnect Switch - 3P, 30A 575V 1 1 1 049750701 DS1 Disconnect Switch - 3P, 80A 575V 1 1 049750702 Electric Heat Units DS3 Disconnect Switch - 10-30Kw, 3P, 100A 208/230V 1 1 1 1 1 049750703 DS3 Disconnect Switch - 40Kw, 3P, 125A 208/230V 1 1 1 1 1 049750704 DS3 Disconnect Switch - 50-60 Kw, 3P, 250A 208/230V 1 1 1 1 1 049750705 DS3 Disconnect Switch - 10-40Kw, 3P, 80A 460V 1 1 1 1 1 049750702 DS3 Disconnect Switch - 50-60Kw, 3P, 100A 460V 1 1 1 1 1 049750703 DS3 Disconnect Switch - 10-60Kw, 3P, 80A 575V 1 1 1 1 1 049750702 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 27

Field Installed Accessories Thermostats & Miscellaneous DESCRIPTION UNIT PART NUMBER THERMOSTAT 1H/1C, Manual Changeover With "FAN ON" and "HEAT-OFF-COOL" switch. ALL 065495901 Honeywell T8034C Series Includes Subbase THERMOSTAT 2H/2C, Auto Changeover ALL 065495805 Honeywell T874 Series Use with Subbase 065495801 or 065495802 SUBBASE Use with T874 Thermostat Without switches ALL 065495801 With switches ALL 065495802 THERMOSTAT 2H/2C, 7-Day Programmable, 2 Occupied / 2 Unoccupied periods per day, ALL 049024906 Auxiliary Relay to close Economizer during unoccupied cycle, 60-hour battery backup, Auto Changeover, 2 LEDs for user defined indication. Honeywell T7300 Series Use with Subbase 049024904 SUBBASE Use with T7300 Thermostat With switches ALL 049024904 LOCKING THERMOSTAT COVER Honeywell TG511A Series ALL 066406601 Use with T8034C & T874 Thermostats Honeywell TG512A Series ALL 066406701 Use with T7300B Thermostat REMOTE AIR SENSOR Honeywell T7047C Series ALL 065496401 Use with T7300 Thermostat REMOTE STATUS PANEL Honeywell W950 Series 4 Light, without switches ALL 065491501 4 Light, with switches ALL 065491502 6 Light, without switches ALL 065491503 6 Light, with switches ALL 065491504 MONITOR PACKAGE Provides LEDs in unit to indicate "COOL, HEAT ON, COOL FAIL and HEAT FAIL" ALL 055421701 Also provides terminals for field connections of Remote Status Panel TIMECLOCK 7 Day, Mechanical ALL 071195601 Commercial Unitary Rooftop; CUR 075-150 Vin. G Rev. A 11/16 RPL 0571027 / Page 28