CENTRAL AIR CONDITIONERS MINI CHILLER SERVICE MANUAL

Similar documents
Condensing Unit Service Manual (T1/R410a/60Hz)

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

Service Manual & Installation Manual

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

R22 air-cooled modular chiller 50Hz unit. Content

Service Manual & Installation Manual

DESHUMIDIFIER MH-V5 Service manual

Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45

ENGINEERED TERMINAL AIR CONDITIONER

CASSETTE TYP FANCOIL UNIT SERVICE MANUAL

Content. The specifications, designs, and information in this book are subject to change without notice for product improvement.

Installation and Operation Manual Air-cooled Mini-Chiller

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

.2 Section Waste Management and Disposal.

MODELS LIST. Nominal Capacity RT

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Air-Cooled Mini Chiller. Models: AMAC 040 A/AR AMAC 050 A/AR AMAC 058 A/AR AMAC 075 B/BR AMAC 100 B/BR AMAC 125 B/BR. Manual No: TMA-AMAC-1161

RC-54CA RO-50CA RC-54HA RO-50HA. SPLIT TYPE AIR CONDITIONER CASSETTE TYPE (50Hz) Indoor unit Outdoor unit

Air Conditioner Service Manual

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode

Floor-Standing Type(E Series)

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

Service Manual. Models WAH418230MB WH418ZMB WAH424230MB WH424ZMB

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

Service Manual. Cutee Serie. Please be aware that all product codes beginning with GPC are to be seen as the TOSOT units beginning with TPC.

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

FAN COILS wall mounted

Service Manual. Air Conditional

Service Manual. Models WAH48115MB WAH412230MB WH48YMB WH412ZMB

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

Air-cooled Mini-Chiller

Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Service Manual. Air Conditional

Wired Remote Controller XK19 and Wireless Remote Controller YT1F

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

C&H NORDIC Commercial 4 SERVICE MANUAL

M P 1 2 F G C O M P R E S S O R TECHNICAL SPECIFICATIO N

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 93AH FILE NO. SA 93AH REFERENCE NO. SM700510

Service Manual A16EW4H4R09 A16EW4H4R12 A16EW4H4R18

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

MANUAL FOR AIR COOLED INDUSTRIAL CHILLERS MODEL: UCS-10A

SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

38LB/38LF AIR COOLED CONDENSING UNIT

DUCT type. Большая библиотека технической документации каталоги, инструкции, сервисные мануалы, схемы.

Thank you for selecting LENNOX air conditioners.

Room Air Conditioner Service and Parts Manual

MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw)

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 128S5 FILE NO. SA 128S5 REFERENCE NO. SM700338

Condensing Unit Installation and Operating Instructions

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

R410A50Hz Universal Outdoor Series Technical Manual

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS

SERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

Air-to-water Heat Pump Monobloc Versati

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

UNDERCOUNTER LABORATORY REFRIGERATORS and FREEZERS Installation, Operation and Maintenance Instructions

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models CONTENTS

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

technical data Fan coil unit FWB small duct unit

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

HSP Ducted Series REFRIGERANT. SM HSP Ducted 1-A.1 GB DECEMBER Version:1

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

INSTALLATION AND OPERATING INSTRUCTIONS (2 Through 10-ton Air Cooled Single Stage Chillers)

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

Harmo Powerpack Horizontal Units Installation & instruction manual

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

INSTALLATION AND USER MANUAL

Power Supply RT. Model. Ph, V, Hz 54 LSBLG190H-M 3,380~415V,50 85 LSBLG290H-M 3,380~415V,50 92 LSBLG325H-M. Model Name 3,380~415V, LSBLG430H-M

[U] Serie MOV. Manual de Ingeniería

Chiltrix 5.1 Thin DC - Inverter Water Fan Coil Unit Floor, Wall or Ceiling Universal Mount Manual

SERVICE MANUAL UNI SPLIT SERIES. ASC-xxBI, ASD-xxBI, ASF-xxBI, ASGE-xxBI, ASGE-xxBI-3

MARINE SELF-CONTAINED DIRECT EXPANSION AIR CONDITIONING SYSTEMS

LSK LSK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Floor Ceiling Type Fan Coil Unit Service Manual ( GC I )

Service Manual. Procedure. 4. Remove top cover. Top cover sub-assy. Remove the screws fixing top cover and then remove the top cover.

G-10f/GCG-10f UPRIGHT COOLER

FLOOR CONSOLE / UNDER CEILING DUAL type

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

CHILLER. Operator s & Installation Manual

WINDOW YORK TECHNICAL GUIDE. Single package Cooling only and Heat pump. Models YO-YM R407C YO V6 G YO V7 G

Installation and maintenance instructions for cabin units type vertical IDAC (V50)

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS

Shandong Vicot Air Conditioning Co.,Ltd. Modular&Packaged Air Cooled Water Chiller. Shandong Vicot Air Conditioning Co.,Ltd.

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

Transcription:

CENTRAL AIR CONDITIONERS MINI CHILLER SERVICE MANUAL T/R40A/50Hz (GC2004)

CONTENTS PRODUCT...2 MODELS LIST...2. Split Type...2.2 Integral Type...3 2 NOMENCLATURE...3. Split Type...3.2 Integral Type...4 3 FUNCTION...4 4 PRODUCT DATA...5 4. Product Data at Rated Condition...5 4.2 Operation Range...7 4.3 Electrical Data...7 5 PIPING DIAGRAM...7 UNITS CONTROL...9 OPERATION FLOWCHART...9. Cooling Operation...9.2 Heating Operation...0 2 MAIN LOGIC... 2. Cooling Mode... 2.2 Heating Mode... 2.3 Defrosting Mode...2 3 WIRED CONTROLLER...2 3. Dimension...2 3.2 Function...3 3.3 Installation...5 4 CONTROL WIRING DESIGN...6 UNITS INSTALLATION...8 UNITS INSTALLATION...8. Installation Positions...8.2 Matters need Attention...8.3 DIMENSION DATA...8.4 INSTALLATION CLEARANCE DATA...2 2 WATER PIPING WORK...23 2. Installation Procedure...23

2.2 Matters of Attention...23 2.3 Antifreeze...23 3 ELECTRIC WIRING WORK...23 3. Wiring Principle...23 3.2 SPECIFICATION OF POWER CORD & AIR SWITCH...23 3.3 WIRING DIAGRAM...23 UNITS MAINTENANCE...28 ERROR CODE LIST...28 2 FLOW CHART OF TROUBLESHOOTING...29 3 DISASSEMBLY AND ASSEMBLY PROCEDURE OF MAIN PARTS...3 3. Split Type...3 3.2 Integral Type...39 4 EXPLODED VIEWS AND PART LIST...43 4. Exploded Views and Parts List- Split Type...43 4.2 Exploded Views and Parts List- Integral Type...52

PRODUCT

PRODUCT MODELS LIST. Split Type Model Product Code Nominal Capacity Power Supply Appearance Refrigerant Model Name kw (V,Ph,Hz) Outdoor Unit Indoor Unit HLR8WZNa-M I EM3N0030 HLR8WZNa-M HLR8WZNa-M O EM3W0030 EM3W003 8.0 HLR0WZNa-M I EM3N0020 R40A HLR0WZNa-M HLR2.5WZNa-M HLR0WZNa-M O HLR2.5WZNa-M I HLR2.5WZNa-M O EM3W0020 EM3W002 EM3N0040 EM3W0040 0.0 2.5 380 45V 3Ph 50Hz HLR5WZNa-M I EM3N000 HLR5WZNa-M 5.0 HLR5WZNa-M O EM3W000 EM3W00 Note:Ton =2000Btu/h = 3.57kW 2

.2 Integral Type Model Product Code Nominal Capacity Power Supply Appearance Refrigerant Model Name kw (V,Ph,Hz) HLR22SNa-M EM5000030 22 HLR25SNa-M EM6N0270 25 R40A HLR35SNa-M EM6N0260 EM6N026 35 380 45V 3Ph 50Hz HLR45SNa-M EM5000040 EM500004 45 Note:Ton =2000Btu/h = 3.57kW 2 NOMENCLATURE. Split Type HL R 5 W Z Na - M 2 3 4 5 6 7 NO. Description Options Mini chiller - 2 Product type R=Heat pump 3 Nominal Cooling Capacity 4 Struct type 8=8kW 0=0 kw 2.5= 2.5kW 5= 5kW Default=Vertical type W=Horizontal type 5 Z=Combination 6 Refrigerant Na=R40A, Default=R22 7 Voltage M=380 45V 3Ph 50Hz 3

.2 Integral Type HL R 35 S Na - M 2 3 4 5 6 NO. Description Options Mini chiller - 2 Product type R=Heat pump 3 Nominal Cooling Capacity 4 Refrigeration Circuits 22=22kW 25=25kW 35=35kW 45=45kW Default=One circuit S=Twin circuit 5 Refrigerant Na=R40A, Default=R22 6 Voltage M=380 45V 3Ph 50Hz 3 FUNCTION Indoor Unit Type Function Description Split Type Integral Type Heating/Cooling Interface kit for up to 6 indoor units Memory restart Two circuits optimized design Low noise design Safety and reliability thanks to advance compressor balance control 4

4 PRODUCT DATA 4. Product Data at Rated Condition 4.. Split Type Models HLR_WZNa-M 8 0 2.5 5 Product Code Indoor unit EM3N0030 EM3N0020 EM3N0040 EM3N000 Outdoor unit EM3W0030 EM3W003 EM3W0020 EM3W002 EM3W0040 EM3W000 EM3W00 kw 7.5 0 2.5 4.2 Cooling Btu/h 25590 3420 42650 4845 Nominal Capacity RT 2. 2.9 3.6 4.0 kw 9 2 3 6.5 Heating Btu/h 30708 40944 44357 56298 RT 2.6 3.4 3.7 4.7 Power Consumption Cooling kw 3.5 4.4 5.7 5.7 Heating kw 3.3 4.4 4.8 5.3 Refrigerant Compressor Power Supply Safeties Type 380~45V,3Ph,50Hz High/Low pressure switch, compressor thermal protection, over current protection, lose of R40A Charge kg 3. 3.55 4.5 5.5 Type scroll NO. Evaporator Condenser Heat Exchanger Water In/Out Pipe Diameter Heat Exchanger Tube-in-Tube Inch " " " " Fan Motor Power Input kw 0.092 0.068 0.092 0.092 Fan quantity 2 2 2 Pump L/s 0.38 0.48 0.59 0.72 Water Flow GPM 5.0 6.3 7.79 9.5 Delivery Lift m 8 8 8 8 Power Input kw 0.55 0.55 0.55 0.55 Expansion Vessel Volume L 5 5 5 5 Indoor Unit Unit / Packing Dimension Height mm 288/385 288/385 288/385 288/385 Width mm 00/285 00/285 00/285 00/285 Depth mm 450/682 450/682 450/682 450/682 Net/Gross Weights 84/96 84/96 84/96 84/96 Outdoor Unit Unit / Packing Dimension Height mm 840/985 250/385 250/385 250/385 Width mm 950/0 950/0 950/0 950/0 Depth mm 42/450 42/450 42/450 42/450 Net / Gross Weights 90/00 2/23 5/26 23/34 5

4..2 Integral Type Models Product Code EM5000030 EM6N0270 HLR_SNa-M 22 25 35 45 EM6N0260 EM6N026 EM5000040 EM500004 kw 2.5 22.8 3 42 Cooling Btu/h 73358 77794 05773 43304 Nominal Capacity RT 6. 6.5 8.8.9 kw 25 25 37.5 49 Heating Btu/h 8530 8530 27950 6789 RT 7. 7. 0.7 3.9 Power Consumption Cooling kw 8.6 8.8.9 8.3 Heating kw 8.6 8.9 2.5 7.5 Power Supply Safeties 380~45V 3Ph 50Hz High/Low pressure switch, compressor thermal protection, over current protection, lose of phase/anti- Refrigerant Compressor Type R40A Charge kg 3.6 2 4.8 2 6.5 2 7.3 2 Type scroll NO. 2 2 2 2 Heat Exchanger Tube-in-Tube Tube-in-Tube Shell in tube Shell heat exchanger Evaporator Condenser Pump Water In/ Out Pipe Diameter Heat Exchanger Fan Motor Power Input Water Flow Inch " " -/2" -/2" Fin sleeve Heat exchanger kw 0.4 0.4 0.6 0.8 L/s.05.2.4 2.2 GPM 3.9 5.8 22 29 Delivery Lift m 22 24 25 27 Power Input kw 0.75 0.75.5.5 Expansion Vessel Volume L 8 8 8 8 Unit / Packing Dimension Height mm 850/200 850/200 760/970 760/970 Width mm 460/540 460/540 750/90 750/90 Depth mm 530/60 530/60 800/960 800/960 Net/Gross Weights kg 370/380 390/400 680/690 755/765 Notes a. Cooling capacity is based on the following conditions leaving chilled water temp.7,outdoor air temp.35 b. Heating capacity is based on the following conditions leaving warmed water temp.45, outdoor air temp.7 c. d. The maximum allowable pressure for water pipe is 0.9MPa. 6

4.2 Operation Range Mode Range of Outdoor Temperature ( ) Cooling 6~48 Heating -5~28 4.3 Electrical Data 4.3. Split Type Model HLR8WZNa-M Rated Power Supply NO. Compressor LRA each A MRC each A NO. Fan Motor Outdoor MRC A Pump MRC A MRC A Total NRC A 67 9..5 0.7 9.4 7.0 HLR0WZNa-M HLR2.5WZNa-M 380~45V 3Ph 50Hz 66 67.6 3.7 2 2 2.0 2.0 0.7 0.7 3.0 4.5 8.5 0.5 HLR5WZNa-M 67 3.7 2 2.0 0.7 4.5 0.5 4.3.2 Integral Type Model HLR22SNa-M Rated Power Supply NO. Compressor Fan Motor Pump Total LRA each A MRC each A NO. MRC A MRC A MRC A MRC A 2 73.6 2 5.0.5 9.5 4.5 HLR25SNa-M` 380~45V 2 66 3.5 2 5.0.5 23.5 8.5 HLR35SNa-M 3Ph 50Hz 2 0 6.4 2 7.5 3.0 28.5 24.5 HLR45SNa-M 2 8 22.5 2 7.5 3.0 45.0 3.0 Notes: a. LRA: Locked rotor amps (A). b. MRC: Maximum running current (A). c. NRC: Nominal running current (A). 5 PIPING DIAGRAM High-pressure switch Outlet Shell and tube heat exchanger Pump Relief valve Flow Expansion switch drum F Inlet Compressor Low-pressure switch Four-way valve Cooling circuit Heating circuit High pressure tank Liquid-gas separator Aluminum fin-copper tube coil 7

CONTROL 8

UNITS CONTROL OPERATION FLOWCHART. Cooling Operation N Y N Y Y N 9

.2 Heating Operation N Y N Y Y N 0

2 MAIN LOGIC 2. Cooling Mode When pressing ON button, if the outdoor temperature is above 6 outlet water temperature meets the cooling running requirements, the fans of outdoor unit will start. Then the compressor will run in 5s. During the period of cooling, the unit will be turned off if the outlet water temperature meets the stopping requirements and the running time of compressor is over the shortest running time required. The fans of outdoor unit will stop in5s. If the outdoor temperature is below 6, the unit will stop, and all loads except the water pump will be turned off. Turn on Turn off Pump 30S 3min 5S Fan 30S 5S When it is turned off 3min 5S Fan 2 5S 5S Check if flow switch is ok When it is turned off Flow Switch 5S Compressor 0min Compressor 2 5>Tout>2 Four-way valve Four-way valve 2 4>Tout>7 5>Tout>8 2.2 Heating Mode When pressing ON button, if the outdoor temperature is below 28 outlet water temperature meets the heating running requirements, the fans of outdoor unit will start. Then the compressor will run in 5s. During the period of cooling, the unit will be turned off if the outlet water temperature meets the stopping requirements and the running time of compressor is over the shortest running time required. The fans of outdoor unit will stop in5s. If the outdoor temperature is over 28, the unit will stop, and all loads except the water pump will be turned off.

Turn on Turn off Pump 5S 5S Check if flow switch is ok Flow Switch Fan 5S 3min When it is turned off 5S Compressor 5S 30S Four-way valve 30S 3min Fan 2 5S When it is turned off Compressor 2 5S 5S Four-way valve 2 48<Tout<54 46<Tout<52 2S 5S 2.3 Defrosting Mode The condition of start defrosting mode: Under heating mode, if the accumulative running time of compressor is over the set interval time of defrosting default 45min and the defrosting temperature is lower than the set starting temperature(default -4 ),the unit will start running defrosting mode, and the 4-way valve will shut off and the outdoor fan will stop after 2s. The condition of quit defrosting mode: Under defrosting mode, if the continual defrosting time is over the set continual time of defrosting default 8min and the defrosting temperature is over the set stopping temperature(default 20 ),the unit will restart running heating mode, and the 4-way valve will turn on and the outdoor fan will run. 3 WIRED CONTROLLER 3. Dimension 85 42.5 85 85 60 85 85 2.2 installation dimension outline dimension 2

3.2 Function 3.2. Operation View 2 3 4 8 5 6 7 NO. Name Function description MODE button It can switch between cooling and heating. This button is available only on heat pump unit. 2 CHECK button Press it once under normal state to enter check mode. Under check mode, pressing this button when 7 is displayed can change the value of 7. Under parameter setting mode, pressing this once can switch the adjusting objection between parameter and value, and pressing this button for long (about 5s) can save and quit this parameter setting. 3 Increasing button To increase present set value or change set/check object. 4 Decreasing button To decrease present set value or change set/check object. 5 QUIT button Under Set and Check mode, press it once to quit this mode. Under parameter set mode, this set value would not be saved. Press this button for long (about 5s) to set sound, and make sound switch between always on and always off. 6 ON button To turn on the unit; when under compel operation, press it once to quit compel operation. 7 OFF button To turn off the unit; press it once to quit compel operation when the unit is under compel operation. 8 LCD display Display information of the unit. Notes a. Turn On, Off Auxiliary Heater: It is only available for heat pump unit. Press CHECK once to enter Check mode. switches between 0/03 (auxiliary heater on) and 00/02 (auxiliary heater off). That is 00 Off >0 On >00 Off, or 02 Off >03 On >02 Off. b. mode, Auxiliary display area shows the checking object, and Main display area displays the value for the checking object. 3

3.2.2 Display View NO. Name Function description Running mode display : cooling mode, : heating mode, : reserved 2 Temp display It shows temperature value at main display area. 3 Auxiliary display area 4 Main display area It contains 2 numbers and a comma, for showing temperature and number of parameter at main display area. It only displays when under Check mode and Parameter checking mode. It contains a minus, 2 numbers and temperature unit, for displaying value of temperature and parameter (temperature or time value) and error code. When temperature value is displayed, it shows value in algorism and temperature unit; when time is displayed, it shows algorism value but without temperature unit temperature unit. Individual temperature or parameter may exceed 99, then adopt AX for 00 09, bx for 0 9, CX for 20 29, dx for 30 39, EX for 40 49, FX for 50 59, and X stands for a number between 0 9. Under normal state, it shows temperature for back water. 5 Parameter display It means the value shown at present main display area is parameter. It shows only under Parameter Check mode. 6 Defrost display It displays when defrosting; otherwise it doesn t displays. 7 System ID It displays when system or compressor orders, for showing which system is defrosting. 8 Testing display For testing, it displays under compel operation. It shows the error code displayed on Main Display Area. It displays when there is error at system or 9 Error code display communication. Caution: ) When unit is off, it displays only temperature of back water. When unit is on, under normal state, if there is no error, it displays temperature of back water, if there is error, it displays error code; when there is no operation after 60s of pressing the button, it quit back to normal state display automatically. 2) Auto antifreeze operation display (only for heat pump unit) 4

this time, LCD main display area displays code d2 (if there is error it displays error code). 3.3 Installation ) First select an installation position. According to the size of the communication line of the wire controller, leave a recess or an embedded wire hole to bury the communication line. 2) If the communication line between the wire controller (85 85 20) and the indoor unit is surface-mounted, use # PVC pipe and make matching recess in the wall (refer to Figure 6); If concealed installation is adopted, # PVC pipe can be used (Refer to Figure 7). 3) No matter if surface mounting or concealed mounting is selected, it is required to drill 2 holes (in the same level) which distance shall be the same as the distance (60mm) of installation holes in the bottom plate of the wire controller. Then insert a wood plug into each hole. Fix the bottom plate of the wire controller to the wall by using the two holes. Plug the communication line onto the control panel. Lastly install the panel of the wire controller. Caution: During the installation of the bottom plate of the wire controller, pay attention to the direction of the bottom plate. The plate s side with two notches must be at the lower position, and otherwise the panel of the wire controller cannot be correctly installed. PVC pipe Fig6 Surface Mounting of Cable Fig7 Concealed mounting of Cable 2 3 4 Fig 8 Schematic Diagram of Installation Caution: No. Name Wall Surface 2 Bottom Plate of Wire Controller 3 Screw M4X0 4 Panel of Wire Controller ) The communication distance between the main board and the wire controller can be as far as 20m (The standard distance is 8m). 2) The wire controller shall not be installed in a place where there is water drop or large amount of water vapor. 5

4 CONTROL WIRING DESIGN Indoor Unit Controller CN CN2 twisted-pair twisted-pair J Manual Unit Controller X7 Outdoor Unit Controller The controllers of the split type unit include manual controller, indoor unit controller and outdoor unit controller. The indoor unit controller communications with manual controller and outdoor unit controller in RS485. The indoor unit controller connects manual controller with 4-line twisted-pair. Similarly, the indoor unit controller connects outdoor unit controller with 4-line twisted-pair. Indoor Unit Controller Manual Unit Controller J twisted-pair X7 Outdoor Unit Controller The controllers of the Integral type unit include manual controller and outdoor unit controller. The manual controller communications with outdoor unit controller in RS485. The manual controller connects outdoor unit controller with 4-line twisted-pair. 6

INSTALLATION 7

UNITS INSTALLATION UNITS INSTALLATION. Installation Positions For indoor unit: ) Fix the indoor unit bracket to the wall using appropriate plugs and screws. 2) Hang the indoor unit on the top wall mounting bracket. 3) Fix the indoor unit at the bottom side using appropriate plugs and screws. For outdoor unit: ) The installation is frost-free. 2) The space around the unit is adequate for servicing. 5) All piping lengths and distances have been taken into consideration..2 Matters need Attention 2) At delivery, the unit should be checked and any demage should be reported immediately to the carrier claims agent. 3) Check if all indoor unit accessories are enclosed. 4) The indoor unit is heavy and should be lifted by two persons..3 DIMENSION DATA ) Split type HLR8WZNa-M(O) Unit: mm 950 340 840 378 572 42 8

HLR0WZNa-M(O) HLR2.5WZNa-M(O) Unit: mm 950 42 370 340 250 572 HLR5WZNa-M(O) Unit: mm 950 42 370 340 250 590 20 9

HL(R)8WZNa-M(I) HL(R)0WZNa-M(I) HL(R) 2.5WZNa-M(I) HL(R)5WZNa-M(I) Unit: mm 450 52 288 572 00 2) Integral Type HLR22SNa-M HLR25Na-M Unit: mm 850 G" outlet G" inlet G/2" Water-filled vavle Basement 260 fixing hole 530 460 Diameter 2mm 544 20

HLR35Na-M.HLR45Na-M Unit: mm.2 INSTALLATION CLEARANCE DATA ) Split type Outdoor unit air inlet L L3 L4 air outlet L2 unit mm demonstration L L2 L3 L4 distance >500 >000 >500 >500 2

2) Split type Indoor unit L3 L Seismic Spring Isolators L2 unit mm demonstration L L2 L3 distance >250 >800 >200 Integral Type 22

2 WATER PIPING WORK 2. Installation Procedure outdoor unit please refer to the outdoor unit installation manual. The units are equipped with a water inlet and water outlet for connection to a water circuit, which must be provided by a licensed technician and must comply with all relevant national regulations. 2.2 Matters of Attention Air vents must be provided at all high points of the system. The vents should be located at points which are easily accessible for servicing. An automatic air purge should be used. Check the valve is not tightened too much so that automatic release of air in the water circuit remains possible. 2.3 Antifreeze 0 2 22 30 36 4 Freezing Point 0(32) -5(23) -0(4) -5(5) -20(-4) -30(-22) Ambient Temperature 8.3(47) 3.3(38) -.7(29) -6.7(20) -.7() -6.7(2) Cooling Capacity Correction Factor.0 0.985 0.980 0.974 0.970 0.965 Water Flow Correction Factor.0.02.04.075..4 Pressure Drop Correction Factor.0.07..8.22.24 3 ELECTRIC WIRING WORK 3. Wiring Principle POWER SUPPLY The electrical characteristics of the available power supply must agree with the unit nameplate rating. Supply voltage must be within the limits shown. See 3.3 for electrical and configuration data. FIELD POWER circuit fused disconnect(s) of a type that can be locked off or open. Disconnect(s) must be located within sight and readily accessible. 3.2 SPECIFICATION OF POWER CORD & AIR SWITCH Model Power Supply Capability of Air Switch(A) Minimum Sectional Area of Earth Wire(mm 2 ) Minimum Sectional Area of Power Cord(mm 2 ) HLR8WZNa-M 380 45V,3,50 0 2.5 2.5 HLR0WZNa-M 380 45V,3,50 3 2.5 2.5 HLR2.5WZNa-M 380 45V,3,50 6 2.5 2.5 HLR5WZNa-M 380 45V,3,50 6 2.5 2.5 HLR22SNa-M 380 45V,3,50 25 4 4 HLR25SNa-M 380 45V,3,50 32 6 6 HLR35SNa-M 380 45V,3,50 63 0 0 HLR45SNa-M 380 45V,3,50 63 0 0 23

3.3 WIRING DIAGRAM 3.3. Wiring Diagram-Split Type 3.3.. Outdoor Units Model: HLR8WZNa-M(O) - N PE W3 BK W BU W9 RD W4 BU W2 RD W5 BU XT2 2 W6 WH W7 W9 RD WH X7 2 2 W8 WH KM TC AP C2 4 2 W20 W RD BU C W3 BU 6 W22 BN W2 YE 8 Electric heater 0 KM 2 EH W2 BU WHBUBK C2 BN BN 5 4 3 6 M W0WH AP2 indoor unit W8 W7 RD RD XT3 2 W5 BN W6 BN TC C XT2 XT3 XT E W4 YEGN compressor E Fan motor YEGN PE PE Model: HLR0WZNa-M(O) HLR2.5WZNa-M(O) POWER XT N XT2 2 2 2 2 2 X9 X0 X7 X8 PE KM KM2 C3 2 C4 2 TC KM T C 2 KM2 T C2 2 3 3 5 4 W42 6 2 5 4 6 W43 X3 X32 W45 3 5 4 W47 6 3 2 5 4 6 W48 X33 X34 W56 W33 W34 W37 W38 W35 W36 W49 W50 W5 W52 M M2 W30 W27 W32 W3 W28 W29 XT3 E E W24 E E PE PE PE PE COMPONENT POSITION DIAGRAM C4 C3 XT2 2 AP2 TC C2 C AP KM KM2 XT XT3 24

Model: HLR5WZNa-M(O) W33 W3 W37 W3 W3 W3 W W W W W W W3 W3 W3 W 7 3.3..2 Indoor Units POWER XT N L PE PE N L BN 7BU L N 2RD 8BU A9BU A KM KM2 A2 A2 3OG 4GN XT-2 HT XT- 5 OG heat pump 5RD L KM T EH HEATER end_switch 3YE L KM2 T 4BU 6YE W2 U M W pump 6 YEGN PE TC CN3 CN CN2 OVERLOAD W_FLOW +2V AP2 CN2 flow CN4 in CN5 flow out CN6 anti-ice CN Water-Inlet Temp.Sensor Water-Outlet Temp.Sensor Frost-proof Temp.Sensor OUTDOOR UNIT X7 AP 2WH FL 0BK BK 4 AP3 X controller COMPONENT POSITION DIAGRAM AP2 TC KM KM2 XT 25

3 3 Mini Chiller Service Manual 3.3.2 Wiring Diagram- Integral Type Model: HLR22SNa-M HLR25SNa-M R S T PE E 3 3 3 M M2 M3 E E E E 723 PE PE PE PE PE 724 TC Specification:.Auxiliary electric heater is optional part for heat pump unit, once it is used, please connect the temp. restricter HT with XT2.- and XT2.-2. 2. Cooling only type unit do not have below parts: KM5, Auxiliary electric heater, LP2, LP22, Defrost temp. sensor. 3. if the chiller is connected with fancoil units, please remove the wire between AC-L and X6 on PC, then connect X6 to X on fancoil unit patching board. 4. Remarks: " " means terminals on XT2. or XT2.2 patching board. Model: HLR35SNa-M HLR45SNa-M M M2 M3 E E E E E 26

MAINTENANCE 27

UNITS MAINTENANCE ERROR CODE LIST Code Indication Error Name Control Description E Comp. High-pressure protection Press ON/OFF key to clear E2 System antifreeze protection Auto resume E3 Comp. Low pressure protection Press ON/OFF key to clear E4 Comp. Discharge temp. protection Press ON/OFF key to clear E5 Comp. overload protection Press ON/OFF key to clear E6 Pump overload protection Press ON/OFF key to clear E7 Flow switch failure Press ON/OFF key to clear E8 Fan overload protection Press ON/OFF key to clear E9 System outlet water temp. too high Auto resume b Comp. 2 High-pressure protection Press ON/OFF key to clear b2 System 2 antifreeze protection Auto resume b3 Comp. 2 Low pressure protection Press ON/OFF key to clear b4 Comp. 2 Discharge temp. protection Press ON/OFF key to clear b5 Comp. 2 overload protection Press ON/OFF key to clear b8 Fan 2 overload protection Press ON/OFF key to clear b9 System 2 outlet water temp. too high Auto resume F Antifreeze temp. sensor failure Auto resume F2 Antifreeze temp. sensor 2 failure Auto resume F3 Defrost temp. sensor failure Auto resume F4 Defrost temp. sensor 2 failure Auto resume F5 Discharge temp. sensor error Auto resume F6 Discharge temp. sensor 2 error Auto resume F7 Outdoor ambient temp. sensor failure Auto resume F8 Inlet water temp. sensor failure Auto resume F9 Outlet water temp. sensor failure Auto resume EC Communication malfunction Auto resume 28

2 FLOW CHART OF TROUBLESHOOTING The unit cannot start Power off Yes Stop and restart No If the power supply is normal Yes If fuse burnt Yes Replace the fuse No If three-phase unit Yes If phase sequence protection Adjust any two phases No No If the power of mainboard is failure No If the power cable is fallen Yes Cut off the power, restart after the power is resumed Yes No Replace the mainboard Yes Mainboard is broken If the fuse is burnt Yes Replace the fuse No No Reconnect Yes The connection wire between display board and mainboard is loosened If the transformer is burnt Yes Replace the transformer No If The display board is broken No Replace the display board 29

E7 failuer The Power cable is loosened Yes No If the pump start No If the contactor failure Yes Replace the contactor No No Adjust the phase sequence Yes If the pump rotates in reverse direction Yes No If three-phase unit No If the pump failure Yes Replace the pump If the flow switch failure Yes If the wire is fallen Cut off the power, restart after the wire is resumed No No Clean the filter Yes The filter is blocked Clamp the target to pipe Yes Adjust the size and angle of the target No No Replenish the water No The replenish is sufficient The target is broken Yes Replace the target Yes The valve open too small Yes Adjust the openness of the valve 30

3 DISASSEMBLY AND ASSEMBLY PROCEDURE OF MAIN PARTS 3. Split Type 3.. Outdoor Unit Operation Procedure Illustration ) Remove the front case a) Remove the panel Loosen the two tapping screws fixing the front grill. Pull down and remove the front grill. See Fig. 2 Fig. b) Remove the cover. Loosen the two tapping screws fixing the cover. Remove the cover See Fig. 3 Fig. 2 Fig. 3 3

c) Remove the front plate. Loosen the two tapping screws fixing the front plate. Remove the front plate. See Fig. 5 Fig. 4 grill d) Remove the grill Loosen the two tapping screws fixing the grill. Remove the grill. See Fig. 6 Fig. 5 Fig. 6 32

2) Remove the axial fan and remove the washer. See Fig. 7 Pull outward to remove the impeller. See Fig. 7 Ball Nut Fig. 7 3) Remove the motor Remove the motor support. See Fig.8 & Fig.9 Motor support Fig. 8 Fig. 9 33

Loosen the two screws fixing the motor. Pull backward and remove the motor. See Fig.0 Loosen the wire of motor, and pull it through the hole. Fig. 0 4) Remove the 4-way valve and capillary tube a Remove the 4-way valve Remove the coil of 4-way valve Welding out the tubes connected to the 4-way valve. Remove the 4-way valve. See Fig. Note When welding, the valve should be covered by wet cloth in order to avoid the high temp. hurt b Remove the capillary tube Welding out the tubes connected to the capillary tube. Remove the capillary See Fig.2 Fig. Fig. 2 34

5) Remove electric box pressure switches and temp. sensor. See Fig.3 Noise-absorbing cover Fig.3 6) Remove compressor and gas-liquid separator Remove the connection wire of compresso See Fig.4 welding out the suction pipe and discharge pipe. See Fig.4 Loosen the bolts fixing the compressor and Remove the compressor and gas-liquid separator. Gas-liquid separator Fig.4 Compressor 35

7) Remove gas and liquid valve a) Remove gas valve welding out the pipe connected to the gas valve (See Fig.5 Note When welding, the valve should be covered by wet cloth in order to avoid the high temp. hurt Gas valve bolts b) Remove liquid valve welding out the pipe connected to the liquid valve (See Fig.6 Note When welding, the valve should be covered by wet cloth in order to avoid the high temp. hurt liquid valve Fig.5 bolts Fig.6 36

3..2 Indoor Unit Operation Procedure Illustration ) Remove the Cover the cover. See Fig. Remove the cover See Fig. 2 Fig. Fig. 2 2) Remove electric box pressure switches and temp. sensor. See Fig.3 3) Remove the water pump the water pump. See Fig. 4 Electric box Fig. 3 Fig. 4 Water pump 37

4) Remove the tube in tube heat-exchanger welding out the pipes connected to the tube in tube heat-exchanger. Remove the tube in tube heatexchanger. See Fig. 5 See Fig. 6 Tube in tube heat-exchanger Fig. 5 6) Remove the expansion gas tank Remove the expansion gas tank. See Fig. 7 Flow switch Fig. 6 Expansion gas tank Fig. 7 38

3.2 Integral Type ) Remove the front case See Fig. Pull down and remove the front case. See Fig. 2 Fig. Fig. 2 39

2) Remove electric box pressure switches and temp. sensor. See Fig.3 3)Remove compressor and gas-liquid separator Remove the connection wire of compressor See Fig.4 welding out the suction pipe and discharge pipe. See Fig.4 the compressor and gas-liquid separator. Electric box Fig. 3 Gas-liquid separator Fig. 4 Compressor 40

4 Remove the water pump water pump. See Fig. 5 5 Remove the expansion gas tank Loosen the joints fixing the expansion gas tank. Remove the expansion gas tank. See Fig. 6 Expansion gas tank Water pump Fig. 5 Fig. 6 4

6 See Fig. 7 7 Remove the shell and tube heat-exchanger welding out the pipes connected to the shell and tube heat-exchanger. Remove the shell and tube heatexchanger. See Fig. 8 Flow switch Fig. 7 Shell and tube heat-exchanger Fig. 8 42

4 EXPLODED VIEWS AND PART LIST 4. Exploded Views and Parts List- Split Type 4.. Outdoor Units Model HLR8WZNa-M(O) Exploded Views: 4 2 3 5 2 3 4 5 6 6 0 7 7 8 9 8 9 27 26 28 29 25 24 23 2 20 30 22 Model HLR8WZNa-M(O) for EM3W0030 EM3W003 No. Name of Part Part Code Quantity Front Grill 2226540 2 Cabinet 043503P 3 Protection Grill 047540 4 Top Cover 025502P 5 Rear Side Plate Sub-Assy 0305402 6 Handle 26235253 2 7 Valve Support 075402 8 Metal Base 0205402 09206P 9 Front Side Plate 0305403 0 Axial Flow Fan 033540 Condenser Assy 025703 2 Motor Support 0705402 3 Motor LW92D 50540 4 Isolation Plate 0235403 024202 5 4-way Valve (SHF-20H) 43000338 6 Magnet Coil 430004002 7 Compressor C-SBN303H8D 0029050 8 Cut off Valve 073022 43

9 Cut off Valve 073020 20 Pressure Switch 46020006 2 Temp Sensor 39000226 22 Electric Box Sub-Assy 039229 23 Terminal Board 420043 24 Transformer 57X25D 430240 25 Terminal Board 42003 26 MainPCB WZ63 3022602 27 Capacitor CBB6 4uF/500V 330003 28 AC Contactor GC3-8/0KK/3TF42 4400226 29 Insulation Gasket 7040503 7040523 2 30 Wire Clamp 70002 2 Note: is only used in EM3W0030 is only used in EM3W003 Model: HLR0WZNa-M(O) HLR2.5WZNa-M(O) HLR5WZNa-M(O)) Exploded views: 44

Model HLR0WZNa-M(O) for EM3W0020 EM3W002 NO Name of Part Part Code Quantity Front Grill 2226525 2 2 Front Plate 0435433 3 Protection Grill 0475432 4 Top Cover 025503P 5 Back Side Plate 0305434 6 Handle 26235253 2 7 Valve Support 07500 8 Metal Base 0205433 09207P 9 Front Side Plate 030543 0 Protection Grill Gasket 0 Axial Flow Fan 0335253 2 2 Condenser Assy 025702 3 Motor Support Sub-Assy 070547 4 Motor FW68G 5030 2 5 Isolation Plate 0235440 024220 6 Gas-liquid Separator Sub-Assy 072250 7 4-way Valve 43000338 8 Compressor C-SBN373H8D 002905 9 Cut-off Valve 073022 20 Cut-off Valve 07302392 2 Ambient Sensor(5K) 39000226G 22 Temperature Sensor (20K) 39000225 G 23 Temp. Limiter 0 24 Electric Box Sub-Assy 039222 25 Wire Clamp 70002 2 26 Terminal Board 420043 27 Terminal Board 42003 28 Terminal Board 0 29 330000 2 30 AC Contactor GC3-8/0KK/3TF42 4400226 3 Over current Protector 460202 32 Phase Reverse Protector 0 33 Insulation Gasket 7040503 2 34 Magnet Coil 430004002 35 Compressor Gasket 0 36 Capillary Sub-Assy 040208 37 pressure switch 46020006 38 Capacitor Clamp 0 39 Transformer 57X25D 430240 40 Main PCB WZ63 3022602 Note: is only used in EM3W0020 is only used in EM3W002 45

Model HLR2.5WZNa-M(O) for EM3W0040 NO Name of Part Part Code Quantity Front Grill 2226525 2 2 Front Plate 0435433 3 Protection Grill 0475432 4 Top Cover 0255262 5 Back Side Plate 0305434 6 Handle 26235252 3 7 Valve Support 07500 8 Metal Base 0205433 9 Front Side Plate 030543 0 Protection Grill Gasket 0 Axial Flow Fan 0335253 2 2 Condenser Assy 025702 3 Motor Support 070543 4 Motor FW68G 5030 2 5 Isolation Plate 0235440 6 Liquid-gas Separator 07225433 7 4-way Valve 43000338 8 Compressor C-SBN373H8D 0002702 9 Gas Valve 073022 20 Liquid Valve 073025 2 Ambient Sensor(5K) 39000226 22 Temperature Sensor (20K) 39000225 23 Temp. Limiter 0 24 Electric Box 0409067 25 Wire Clamp 70002 2 26 Terminal Board 420044 27 Terminal Board 42003 28 Terminal Board 0 29 330000 2 30 AC Contactor GC3-8/0KK/3TF42 4400226 3 Over current Protector 460202 32 Phase Reverse Protector 0 33 Isolation Washer D 7040525 2 34 4-way Valve Coil 430004002 35 Compressor Gasket 0 36 Capillary Assy 0405702 37 Pressure Switch 46020006 38 Capacitor Clamp 0 39 Transformer 57X25D 430240 40 Main PCB WZ63 3022602 46

Model HLR5WZNa-M(O) for EM3W000 EM3W00 NO Name of Part Part Code Quantity Front Grill 2226525 2 2 Front Plate 0435433 3 Protection Grill 0475432 4 Top Cover 0255472 5 Back Side Plate 0305434 6 Handle 26235253 2 7 Valve Support 07500 8 Metal Base 0205472 09209P 9 Front Side Plate 030543 0 Protection Grill tub 4203520 Axial Flow Fan 0335253 2 2 Condenser Assy 02202 3 Motor Support 070547 4 Motor LW92C 50545 2 5 Isolation Plate 0235473 0242202 6 Liquid-gas Separator Sub-Assy 07225479 7 4-way Valve 43000338 8 Compressor C-SBN453H8D 0029052 9 Cut-off Valve 073020 20 Cut-off Valve 07302335 2 Ambient Sensor(5K) 39000226G 22 Temperature Sensor (20K) 39000225G 23 Temp. Sensor 3900027G 24 Electric Box 039208 25 Wire Clamp 70002 2 26 Terminal Board 420044 27 Terminal Board 42003 2 28 Terminal Board 0 29 Capacitor 4uF/500V 330003 2 30 AC Contactor LCD250M7C 440023 3 Over current Protector 4602003 32 Phase Reverse Protector 380V 46020052 33 Isolation Washer C 7040523 34 Magnet Coil 430004005 35 Compressor Gasket 7670209 4 36 Capillary Assy 040202 37 pressure switch 46020006 38 Capacitor Clamp 0 39 Transformer 57X25D 430240 40 Main PCB WZ63 3022602 Note: is only used in EM3W0020 is only used in EM3W002 47

4..2 Indoor Units Model HLR8WZNa-M(I) HLR0WZNa-M(I) HLR2.5WZNa-M(I) HLR5WZNa-M(I) Exploded views: 30 29 28 27 26 25 24 23 22 2 20 9 3 32 33 34 35 36 37 4 3 2 0 9 8 7 6 5 8 7 2 5 6 Model HLR8WZNa-M(I) for EM3N0030 NO Name of Part Part Code Quantity Water Pump 433828 2 Vertical Pillar Assy 075826 4 3 Pedestal Parts 02029 4 Front Panel Assy 0538247 5 Electric Box cover 048237 6 Electric Box 048235 7 Temperature Sensor 3900029 8 Temperature Sensor 3900027 9 Temperature Sensor 39000989 0 Terminal Board 4200254 AC Contactor CJX9B-25S/D 4400245 2 Transformer 57X25D 430240 3 Main Board 302250 4 Electric Component Mounting Plate 0338243 5 Wiring 400 6 Display Board 3029603 7 Left Side Plate 03026 8 Double Pipe Heat Exchanger 0090823 9 Expansion Drum 0722829 20 Cross Beam Sub-Assy 0778240 2 Rear Panel Assy 0538250 48

22 Cross Beam Sub-Assy 0778240 23 Top Cover 0252 24 Collecting Gas Pipe Sub-Assy 046720 25 Liquid Divider Sub-Assy 0432208 26 Gas Pipe Sub-Assy 038259 27 Liquid Sub-Assy 0323257 28 Outlet Water Pipe Sub-Assyv 03248247 29 Big Handle 2623343 30 Relief Valve 0788204 3 Tube Clip 0248224 32 Enter Water Pipe Sub-Assy 03248248 33 Right Side Plate 03028 34 Water switch FSF50P-2G/2 45028207 35 Auto Water Replenishing Valve 0708207 36 Right Side Plate 2 03024 37 Water tube jam 767820 Model HLR0WZNa-M(I) for EM3N0020 NO Name of Part Part Code Quantity Water Pump MHI202 433828 2 Vertical Pillar Assy 075826 4 3 Pedestal Parts 02027 4 Front Panel Assy 0538247 5 Electric Box cover 048237 6 Electric Box 048235 7 Temperature Sensor 3900029 8 Temperature Sensor 3900027 9 Temperature Sensor 3900026 0 Terminal Board 4200254 AC Contactor CJX9B-25S/D 4400245 2 Transformer 57X25D 430240 3 Main Board Z53 302250 4 Electric Component Mounting Plate 0338243 5 Wiring 400 6 Display Board Z630 3029603 7 Left Side Plate 03026 8 Double Pipe Heat Exchanger 00908229 9 Expansion Drum 0722829 20 Cross Beam Sub-Assy 0778240 2 Rear Panel Assy 0538250 22 Cross Beam Sub-Assy 0778236 23 Top Cover 025209 24 Collecting Gas Pipe Sub-Assy 046720 25 Liquid Divider Sub-Assy 0432208 49

Mini Chiller Service Manual 26 Gas Pipe Sub-Assy 0463202 27 Liquid Sub-Assy 0432206 28 Outlet Water Pipe Sub-Assyv 03248246 29 Big Handle 2623343 30 Relief Valve 0788204 3 Tube Clip 0248224 32 Enter Water Pipe Sub-Assy 03248248 33 Right Side Plate 03207 34 Water switch FSF50P-2G/2 45028207 35 Auto Water Replenishing Valve 0708207 36 Right Side Plate 2 03024 37 Water Tube Jam 767820 Model HLR2.5WZNa-M(I) for EM3N0040 NO Name of Part Part Code Quantity Water Pump MHI202 433828 2 Vertical Pillar Assy 075826 4 3 Pedestal Parts 02027 4 Left Side Plate 03026 5 Electric Box cover 048237 6 Electric Box 048235 7 Temperature Sensor 3900029 8 Temperature Sensor 3900027 9 Temperature Sensor 3900026 0 Terminal Board 4200254 AC Contactor CJX9B-25S/D 4400245 2 Transformer 57X25D 430240 3 Main Board Z53 302250 4 Electric Component Mounting Plate 0338243 5 Wiring 400 6 Display Board Z630 3029603 7 Left Side Plate 03026 8 Double Pipe Heat Exchanger 00908229 9 Expansion Drum 0722829 20 Cross Beam Sub-Assy 0778240 2 Rear Panel 0538250 22 Cross Beam Sub-Assy 0778236 23 Top Cover 025209 24 Collecting Gas Pipe Sub-Assy 046720 25 Liquid Divider Sub-Assy 0432208 26 Gas Pipe Sub-Assy 0463202 27 Liquid Sub-Assy 0432206 28 Outlet Water Pipe Sub-Assyv 03248247 29 Big Handle 2623343 30 Relief Valve 0788204 3 Tube Clip 0248224 50

32 Enter Water Pipe Sub-Assy 03248248 33 Right Side Plate 03207 34 Water switch FSF50P-2G/2 45028207 35 Auto Water Replenishing Valve 0708207 36 Right Side Plate 2 03024 37 Water Tube Jam 767820 Model HLR5WZNa-M(I) for EM3N000 NO Name of Part Part Code Quantity Water Pump MHI202 433828 2 Vertical Pillar Assy 075826 4 3 Pedestal Parts 02027 4 Left Side Plate 03026 5 Electric Box cover 048237 6 Electric Box 048235 7 Temperature Sensor 3900029 8 Temperature Sensor 3900027 9 Temperature Sensor 3900026 0 Terminal Board 4200254 AC Contactor CJX9B-25S/D 4400245 2 Transformer 57X25D 430240 3 Main Board Z53 302250 4 Electric Component Mounting Plate 0338243 5 Wiring 400 6 Display Board Z630 3029603 7 Left Side Plate 03026 8 Double Pipe Heat Exchanger 00908229 9 Expansion Drum 0722829 20 Cross Beam Sub-Assy 0778240 2 Rear Panel 0538250 22 Cross Beam Sub-Assy 0778236 23 Top Cover 025209 24 Collecting Gas Pipe Sub-Assy 046720 25 Liquid Divider Sub-Assy 0432208 26 Gas Pipe Sub-Assy 0463202 27 Liquid Sub-Assy 0432206 28 Outlet Water Pipe Sub-Assyv 03248246 29 Big Handle 2623343 30 Relief Valve 0788204 3 Tube Clip 0248224 32 Enter Water Pipe Sub-Assy 03248248 33 Right Side Plate 03207 34 Water Switch FSF50P-2G/2 45028207 35 Auto Water Replenishing Valve 0708207 36 Right Side Plate 2 03024 37 Water Tube Jam 767820 5

4.2 Exploded Views and Parts List- Integral Type Model HLR22SNa-M HLR25SNa-M Exploded views Model HLR22SNa-M HLR25SNa-M for EM5000030 EM6N0270 No Name of Part Part Code Quantity Front Panel 2 054202 2 Encloser Sub-assy 0520 3 Fan 0358202 2 4 Grill 05720 2 5 Outlet Pipe Sub-assy 0436202 6 Fan Motor SW200B 50850 2 7 Motor Support Sub-assy 0708222 2 8 Condenser Components 022042 9 Windshield 2 035202 0 Rear Side Plate 032 Right Side Plate Sub-assy 032233 2 Transition Pipe Sub-assy (Four-way Valve-condenser) 0432244 3 Water Tray Sub-assy 028202 4 Vertical Shaft 2 085202 2 5 Transition Pipe Sub-assy 3 (Condenser-Capillary for heating) 04320 6 Four-way Valve Sub-assy 0442226 7 Base Frame Sub-assy 0282253 8 Discharge Pipe Sub-assy 0463224 2 9 Base Plate Sub-assy 092002 52

Mini Chiller Service Manual 20 Suction Pipe Sub-assy 046720 2 Capillary Sub-assy (Heating) 0402220 2 22 Two-direction Liquid Vessel 0722824 2 23 Compressor and Fittings C-SBN373H8D 002905 2 24 Gas-liquid Separator 0722822 2 25 Vertical Shaft Sub-assy 08520 26 Tube-in-tube Heat Exchanger 009020 27 Water Pump MHI404 3 400V 4338206 28 Expansion Vessel 0722829 29 Inlet Pipe Sub-assy 0436203 30 Auto Water Replenishing Valve 0708207 3 Emergency Valve 0788204 32 Water Flow Switch FSF50P-R 45028209 33 Left Side Board Sub-assy 03209 34 Electric Box Sub-assy 03924 35 Front Panel 05420 36 Wind Shield 03520 37 Condenser Components 2 022052 38 Capillary Sub-assy (Cooling) 040222 2 39 Four-way Valve Sub-assy 2 0442227 Model HLR35SNa-M Exploded views 53

Model HLR35SNa-M for EM6N0260 EM6N026 No Name of Part Part Code Quantity Centrifugal Fan 05860 2 2 Fan Motor 508606 2 3 Front Grill 0238202 4 Water Collecting Tray Sub-Assy 027203 5 Back Side Plate 030206 6 Back Side Plate 4 03224P 7 Pipe Connector 062830 2 8 Electric Box Assy 039229 03924 9 Right Side Plate 0308276 0 Dry Evaporator 005086 Magnet Coil 430004008 2 4-way Valve 43000339 3 Current Divider 03400 4 Thermal Expansion Valve 07332226 5 One way Valve 073580 6 Thermal Expansion Valve 07332226 7 One way Valve 073580 8 Discharge Tube Sub-Assy 2 04632240 9 Pressure Protect Switch 46020050 20 Gas-liquid Separator 0742444 2 2 Base Frame Assy 02023 22 Pressure Protect Switch 46020053 23 Inhalation Tube Sub-Assy 2 04672264 24 Compressor Gasket 7683703 8 25 Pressure Protect Switch 460200546 26 0020223 2 27 Compressor Gasket 028049 8 28 Electric heater(compressor) 7655404 2 29 Pressure Protect Switch 46020055 30 Pressure Protect Switch 46020052 3 Inhalation Tube Sub-Assy 04672263 32 Accumulator 07422206 2 33 Pressure Protect Switch 460200547 34 Discharge Tube Sub-Assy 04632239 35 One way Valve 073580 36 Front Side Plate 030203 37 Thermal Expansion Valve 07332226 38 Water Pump 4338204 39 Thermal Expansion Valve 07332226 40 Expansion Drum 0722829 4 Current Divider 03400 42 4-way Valve 43000339 43 Left Side Plate 0308274 54

44 Magnet Coil 430004009 45 One way Valve 073580 46 Strainer 0720037 4 47 45028209 48 Condenser Assy 2 008240 49 Condenser Assy 008239 50 Front Grill 023824 2 5 In-line Sheet Jacket 42030023 2 52 Connecter (fork shape) 42020080 4 53 In-line Lock Sheet 4202007 2 54 Pinboard 302700 55 Display Board 3029005 3029204 56 Auto Water Replenishing Valve 0708207 57 Relief Valve 0788204 58 Auto Air Outlet Valve 0708208 59 Sensor sub-assy 3900220 60 Terminal Board 420204 6 Main Board 302200 3022205 62 Terminal Board 42005 63 Single-phase Air Switch 45020203 64 Phase Reverse Protector 46020054 65 AC Contactor 4400232 66 AC Contactor 440024 67 AC Contactor 4400232 68 AC Contactor 440023 2 69 Terminal Board 4200254 70 Receiver Board 3026003 7 Transformer 4302400 72 Terminal Board 42003 5 Note: is only used in EM6N0260 is only used in EM6N026 55

Model: HLR45SNa-M Exploded views Model HLR45SNa-M for EM5000040 EM500004 56 No Name of Part Part Code Quantity Axial Flow Fan 05860 2 2 Mesh Enclosure 023824 2 3 Front Side Plate 030203 2 4 Column 072203 5 Column 072207 6 Electric Cabinet Sub-assy 039239P 7 Side casing 0768220 2 8 Clapboard Sub-Assy 023828 9 Right Side Plate 0308276 0 Clapboard 3 023820 4-way Valve Sub-Assy 2 2 Discharge Tube Sub-Assy 2 0442252 0442258 0463228 04632292 3 Inhalation Tube Sub-Assy 2 0467230 04672323 4 Gas-liquid Separator 0742444 2 5 Capillary Sub-Assy 0402230 6 Capillary Sub-Assy 0402236 7 Supporting Strip 0892235P 8 Accumulator 07422206 2 9 Back Side Plate 03226P 20 Shell pipe Sub-Assy 04322406 2 Base Plate Sub-Assy 092224P 22 Base Frame Assy 0282286P 23 Condenser bottom border 0862206P 24 Water Collecting Tray Assy 0282287P

25 Front Brace 2 07582 26 Capillary Sub-Assy 0402235 27 Capillary Sub-Assy 04022290 28 Inhalation Tube Sub-Assy 04672309 29 4-way Valve Sub-Assy 0442253 0442259 30 Water pump 4338204 3 Support Sub-Assy for Water Pump 0782320 32 Small Spider 0798208 2 33 Compressor and Fittings 0020523 00202233 2 34 Big Spider Sub-Assy 0798286 2 35 Front Brace 075824 36 Water Pipe Sub-Assy 043620 37 Condenser Outlet Pipe 04322404 38 Expansion vessel 0722829 39 Connection Pipe 05022432 40 45028209 4 Expansion Drum Fixed Mount Sub-Assy 0748220 42 Discharge Tube Sub-Assy 04632280 0463229 43 Brace 07220 44 Clapboard Sub-Assy 2 0238220 45 Left Side Plate 0308274 46 Cross Beam Sub-Assy 087220P 47 Condenser Assy 2 022246 48 Motor Retaining Plate Sub-Assy 0778204 49 Condenser Assy 022247 50 Cross Beam 077823 5 Motor Retaining Plate Sub-Assy 0778206 52 Top Cover Plate 025202P 53 Motor Support Sub-Assy 07082 4 54 Fan Motor 508606 2 55 Top Cover Plate 02520P 56 Electric Box Cover 042224P 57 AC Contactor 440023 2 58 AC Contactor 4400232 2 59 Anti-phase Protector 46020054 60 Single-phase Air Switch 45020203 6 Main Board 302200 62 Terminal Board 42005 63 Terminal Board 420204 64 Terminal Board 4200254 65 Transformer 4302400 66 Receiver Board 3026006 67 Fixed Clamp 70002 68 Terminal Board 42003 5 Note: is only used in EM5000040 is only used in EM500004 57

JF00300239