SPECIFICATIONS hazloclinear LIGHTING 120 & 277 Voltage KEY FEATURES Two Models: 120 vac or 277 vac. Die Cast aluminum fixture for LED heat dissipation and thermal control. 40 watts, 4000 lumens, Epistar Multi-chip LED technology. AC Driver-less system capable of operating at 85C ambient. IP 67/68 rated for wet outdoor locations. Division 1 Groups B, C & D Flammable Gases & Vapors AMBIENT TEMPERATURE 100 C / 212 F I Groups F & G Combustible Dusts Explosion-Proof LED Linear Light Fixture (, Div 1) designed for use in Hazardous Locations forapplications including Oil Refineries, Petrochemical Plants, Painting Facilities and Offshore Oil & Natural Gas Platforms. HTL2-040-50-120-X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL2-040-50-277-X Keeper 2 40 Watts 277v 5000K 4,000 Lm DIMENSIONS 25.875 4.13 6.45 WEIGHT RANGE HTL2 16.3 lbs. Rated Life - 100,000+ hours NEMA 6/6P 5000K Power Factor: >.95 5-Year Warranty ACCESS SELL SHEET Bottom View 25.875 IES PRODUCT LINK 4.13 PRINT VIDEO PRODUCT ORDER SELECTION If button is inactive, the link may be in revision. HTL2 040 50 NA Series Type-Watts Kelvin Voltage Color Mounting Options HTL2 040-40 50-5000K (Std) 22-120 NA-Nat. Aluminum Refer to Complete List of Mounting & Options listed on Page 2. 27-277 (Std) Insert the Item Code(s) Above. HZ The Keeper 11.22.17
120 & 277 Voltage MOUNTING SYSTEMS hazloclinear LIGHTING Wall Mount 90 Ceiling Mount Stanchion Mount 25 Pendant Mount OPTIONS & ACCESSORIES Mounting Options AB Adjustable Bracket - Wall & Hanging SM25 Stanchion Mount 25 PM Pendant Mount
SPECIFICATIONS hazloc LIGHTING 120, 277 & 480 Voltage KEY FEATURES Three Models: 120 vac, 277 vac & 480 vac AC Driver-less system capable of operating from -65 C to 100 C Die Cast aluminum fixture for LED heat dissipation and thermal control. Division 1 Groups B, C & D Flammable Gases & Vapors AMBIENT TEMPERATURE 100 C / 212 F I Division 1 Groups E, F & G Combustible Dusts Explosion-Proof LED Low Bay Light Fixtures (, Div I and I, Div I) designed for use in Hazardous Locations for applications including Oil Refineries, Petrochemical Plants, Painting Facilities and Offshore Oil & Natural Gas Platforms. HTR9-060-50-120-X Monitor 60 60 Watts 120V 5000K 6,000 Lm HTR9-060-50-277-X Monitor 60 60 Watts 277v 5,000K 6,000 Lm HTR9-060-50-480-X Monitor 60 60 Watts 480v 5,000K 6,000 Lm HTR9-080-50-120-X Monitor 80 80 Watts 120v 5000K 8,000 Lm HTR9-080-50-277-X Monitor 80 80 Watts 277v 5,000K 8,000 Lm HTR9-080-50-480-X Monitor 80 80 Watts 480v 5,000K 8,000 Lm HTR9-100-50-120-X Monitor 100 100 Watts 120v 5,000K 10,000 Lm HTR9-100-50-277-X Monitor 100 100 Watts 277v 5,000K 10,000 Lm HTR9-100-50-480-X Monitor 100 100 Watts 480v 5,000K 10,000 Lm DIMENSIONS 7.4 WEIGHT RANGE HTR9 19.8 lbs. Rated Life - 100,000+ hours 5000K Power Factor: >.95 5-Year Warranty ACCESS SELL SHEET 9.2 IES PRODUCT LINK PRINT VIDEO PRODUCT ORDER SELECTION 4.1 If button is inactive, the link may be in revision. HTR9 G Series Type-Watts Kelvin Voltage Color Mounting Options HTR9 060-60 watts 50-5000K (Std) 120v G - Grey (Std) Refer to Complete List of Mounting & Options listed on Page 2. 080-80 watts 30-3000K 277v Insert the Item Code(s) Above. 100-100 watts 480 HZ Monitor 11.22.17
120, 277 & 480 Voltage MOUNTING SYSTEMS hazloc LIGHTING Pendant Mount Wall Mount Hanging Mount Ceiling Mount Stanchion Mount 25 Stanchion Mount 90 Reflectors 16.5 14.5 OPTIONS & ACCESSORIES Mounting Options AB Adjustable Bracket - Wall & Hanging SM25 Stanchion Mount 25 SM90 Stanchion Mount 90 PM Pendant Mount CM Ceiling Mount OTM Oil Tank Mount Reflector Options REF-16 16.5 Reflector REF-14 14.5 Reflector
SPECIFICATIONS hazloc LIGHTING 120-277 & 347-480 Voltage KEY FEATURES Copper-free, die-cast aluminum fixture housing for superior environmental protection. Optical Beam Angle Options (25, 60 & 120 degrees) for wide or narrow area illumination. Separate Fixture and Driver compartments for improved heat dissipation and thermal control. Division 1 Groups C & D Flammable Gases & Vapors Groups A, B, C & D Flammable Gases & Vapors I Groups F & G Combustible Dusts AMBIENT TEMPERATURE 60 C / 140 F Explosion-Proof LED Light designed for use in Hazardous Locations requiring superior ighting. HNSI-080-50-U-X Officer One 80 80 Watts 120-277v 5000K 10,400 Lm HNSI-100-50-U-X Officer One 100 100 Watts 120-277v 5,000K 13,000 Lm HNSI-150-50-U-X Officer One 150 150 Watts 120-277v 5,000K 19,500 Lm HNSI-080-50-48-X Officer One 80 80 Watts 347-480v 5000K 10,400 Lm HNSI-100-50-48-X Officer One 100 100 Watts 347-480v 5,000K 13,000 Lm HNSI-150-50-48-X Officer One 150 150 Watts 347-480v 5,000K 19,500 Lm HNS2-080-50-U-X Officer Two 80 80 Watts 120-277v 5000K 10,400 Lm HNS2-100-50-U-X Officer Two 100 100 Watts 120-277v 5,000K 13,000 Lm HNS2-150-50-U-X Officer Two 150 150 Watts 120-277v 5,000K 19,500 Lm HNS2-080-50-48-X Officer Two 80 80 Watts 347-480v 5000K 10,400 Lm HNS2-100-50-48-X Officer Two 100 100 Watts 347-480v 5,000K 13,000 Lm HNS2-150-50-48-X Officer Two 150 150 Watts 347-480v 5,000K 19,500 Lm 130 Lumens per watt 5000K (Cool) / 4000K (Warm) Power Factor: >.95 5-Year Warranty ACCESS SELL SHEET PRODUCT ORDER SELECTION DIMENSIONS & WEIGHT RANGE located on next page. IES PRODUCT LINK G UB Series Type-Watts Kelvin Voltage Color Mounting - Optics HNSI 080-80 watts 50-5000K (Std) 120-277 G-Gray (Std) Ships with 25-25 HNS2 100-100 watts 45-4500K 347-480 Universal 60-60 150-150 watts Bracket. 120-120 PRINT VIDEO If button is inactive, the link may be in revision. HZ The Officer 11.22.17
120-277 & 347-480 Voltage hazloc LIGHTING MOUNTING SYSTEMS Ceiling Mount Floor Mount Wall Mount Pendant Mount Pole Mount DIMENSIONS WEIGHT RANGE 26.9 lbs. 6 13 11 OPTIONS & ACCESSORIES Mounting Options UB Universal Bracket - Wall, Floor & Ceiling Mount PM Pendant Mount Plate (Threaded) POM Pole Mount Plate (Threaded) Optics 25 25 Optics (Aisle) 60 60 Optics (Medium spread) 120 120 Optics (Wide spread)
SPECIFICATIONS hazloclighting 110 & 220 Voltage Two Driver-Less Models - 40 watt & 60 watt IP 67/68 rated for wet outdoor locations AC Driver-less system capable of operating from -20 C to 100 C Die Cast aluminum fixture for LED heat dissipation and thermal control. Warm white (3000K) and Cool white (5000K) Division 1 Groups B, C & D Flammable Gases & Vapors Division 1 Groups A, B, C & D Flammable Gases & Vapors I Division 1 Groups E, F & G Combustible Dusts AMBIENT TEMPERATURE 100 C / 212 F Explosion-Proof LED Light Fixture designed for use inhazardous Locations for applications requiring a concentration of LED lighting in Low Bay Light situations. A wide variety of mounting capabilities and reflective hoods are available for this well-crafted illuminaire. HTR7-040-50-120-X Lookout 40 40 Watts 120v 5000K 4,000 Lm HTR7-040-50-277-X Lookout 40 40 Watts 277v 5000K 4,000 Lm HTR7-040-50-480-X Lookout 40 40 Watts 480v 5000K 4,000 Lm HTR7-060-50-120-X Lookout 60 60 Watts 120v 5000K 6,000 Lm HTR7-060-50-277-X Lookout 60 60 Watts 277v 5000K 6,000 Lm HTR7-060-50-480-X Lookout 60 60 Watts 480v 5000K 6,000 Lm DIMENSIONS 7.3 Dia. WEIGHT RANGE 7-8 lbs. CRI: >70 Power Factor: >.95 Optical Pattern: 110 5-Year Warranty ACCESS SELL SHEET 9.5 IES PRODUCT LINK PRINT VIDEO PRODUCT ORDER SELECTION If button is inactive, the link may be in revision. HTR7 G Series Type-Watts Kelvin Voltage Color Mounting Options HTR7 040-40 watts 50-5000K (Std) 120-vAC G-Gray (Std) Refer to Complete List of Mounting & Options listed on Page 2. 060-60 watts 30-3000K 277-vAC Insert the Item Code(s) Above. 480-vAC HZ The Lookout 11.22.17
110 & 220 Voltage MOUNTING SYSTEMS hazloclighting Wall Mount Hanging Mount Pendant Mount Stanchion Mount 90 Stanchion Mount 25 Ceiling Mount Reflective Hood OPTIONS & ACCESSORIES Add on Metal Components RH Aluminum Reflective Hood Mounting Options PM Pendant Mount BM Bracket Mount (Std) WM25 Wall mount 25 WM90 Wall mount 90 CM Ceiling mount SM25 Stanchion mount 25 SM90 Stanchion mount 90
SPECIFICATIONS hazlochigh BAY 120-277 Universal & 347-480 High Voltage KEY FEATURES Industry-leading fixture with superior passive cooling fins for high temperature environments. Meanwell Drivers with (20kA) Surge Protection standard. Wide-angle light spread provides superior facility lighting. Die cast aluminum housing (USA-made) with oven baked gray powdered nylon coating (standard) for corrosion resistance. Bridgelux multi-chip VERO-18 LEDs. Groups A, B, C & D Flammable Gases & Vapors AMBIENT TEMPERATURE 65 C / 149 F I Groups F & G Combustible Dusts The best energy efficient, USA-made LED High Bay lighting fixture on the market in North America today, ideal for glare-controlled lighting of large industrial areas with high ceilings. 120-277 Universal Voltage HH06-055-50-EX-U-GR HH06 53 Watts 120-277v 5000K 6,605 Lm HH12-104-50-EX-U-GR HH12 107 Watts 120-277v 5000K 13,406 Lm HH18-170-50-EX-U-GR HH18 170 Watts 120-277v 5000K 19,500 Lm HH22-215-50-EX-U-GR HH22 219 Watts 120-277v 5000K 24,055 Lm HH27-279-50-EX-U-GR HH27 280 Watts 120-277v 5000K 30,651 Lm HH32-368-50-EX-U-GR HH32 383 Watts 120-277v 5000K 39,647 Lm HH40-419-50-EX-U-GR HH40 420 Watts 120-277v 5000K 45,700 Lm 347-480 High Voltage HH06-055-50-EX-48-GR HH06 53 Watts 347-480v 5000K 6,605 Lm HH12-104-50-EX-48-GR HH12 107 Watts 347-480v 5000K 13,406 Lm HH18-170-50-EX-48-GR HH18 170 Watts 347-480v 5000K 19,500 Lm HH22-215-50-EX-48-GR HH22 219 Watts 347-480v 5000K 24,055 Lm HH27-279-50-EX-48-GR HH27 280 Watts 347-480v 5000K 30,651 Lm HH32-368-50-EX-48-GR HH32 383 Watts 347-480v 5000K 39,647 Lm HH40-419-50-EX-48-GR HH40 420 Watts 347-480v 5000K 45,700 Lm PRODUCT ORDER SELECTION Dissipates heat efficiently CRI: >70 Type V distribution Power Factor: >.95 5-Year Warranty ACCESS IES PRINT SELL SHEET PRODUCT LINK VIDEO If button is inactive, the link may be in revision. HH G Series Type-Watts Kelvin Voltage Color Mounting Options HH 06-055 27-279 50-5000K (Std) U-120-277 G-Grey (Std) PM-Pendant Refer to Complete List of Options 12-104 32-368 40-4000K 48-347-480 CH-Closed Hook on Page 2. 18-170 40-419 35-3500K Insert the Item Code(s) Above. 22-215 TheBeast HazLoc HB CS 11.22.17
THE HazLoc HIGH BAY BEAST hazlochigh BAY 120-277 Universal & 347-480 High Voltage MOUNTING SYSTEMS Pendant Mount Pendant with Hook Mount Reflector Hoods Small Hood 30 Dia x 7 H ARRA Buy American American Recovery & Reinvestment Act Medium Hood 30 Dia x 10 H WEIGHT RANGE HH06 HH40 19 lbs. 30 lbs. DIMENSIONS 20.0 8 20.0 Dia. OPTIONS & ACCESSORIES Safety Cables C5 5 foot - 3/32" Safety Cable - Reinforced Loops C10 10 foot - 3/32" Safety Cable - Reinforced Loops Power Cords - Factory Installed CD6 6 ft Cord - 347-480 vac (No Plug, 3 wire) CD12 12 ft Cord - 347-480 vac (No Plug, 3 wire) CDX Customer Specified Cord length - 347-480 vac HLCD5-3 3 ft cord- 5 wire for dimming - 347-480 vac HLCD5-X Customer specified cord length - 5 wire for dimming - 347-480 vac Add on Electrical Components SP Surge Protector (20kA - Standard) Add on Metal Components - Hoods & Cages HDM Medium - 10 inch Hood HDS Small - 7 inch height Hood WGHB Aluminum Protective Wire Guard Mounting Options - Hooks & Pendants PHS Pendant Hook with Safety Clip PHS-PM3 3" Pendant with Hook with Safety Clip PHS-PM6 6" Pendant with Hook with Safety Clip PHS-PM12 12" Pendant with Hook with Safety Clip ITEM CODE PHS-PM18 PHS-PM24 PHL PM3 PM6 PM12 PM18 PM24 Colors GR DESCRIPTION 18" Pendant with Hook with Safety Clip 24" Pendant with Hook with Safety Clip Pendant Hook Loop 3" Galvanized Pendant - Threaded 6" Galvanized Pendant - Threaded 12" Galvanized Pendant - Threaded 18" Galvanized Pendant - Threaded 24" Galvanized Pendant - Threaded Gray - Standard on Haz Loc
SPECIFICATIONS hazloclow BAY 120-277 Universal & 347-480 High Voltage Groups A, B, C & D Flammable Gases & Vapors AMBIENT TEMPERATURE 65 C / 149 F KEY FEATURES Industry-leading fixture with superior passive cooling fins for high temperature environments. Meanwell Drivers with built-in (4kA) Surge Protection standard. Wide-angle light spread provides superior facility lighting. Die cast aluminum housing (USA-made) with oven baked gray powdered nylon coating (standard) for corrosion resistance. Bridgelux multi-chip VERO-18 LEDs. I Groups F & G Combustible Dusts Rugged Hazardous Location, USA-made LED High Bay lighting fixture delivers glare-controlled, highly efficient lighting of large industrial & commercial areas with high ceilings. 120-277 Universal Voltage HL06-055-50-EX-U-GR HL06 53 Watts 120-277v 5000K 6,061 Lm HL12-104-50-EX-U-GR HL12 106 Watts 120-277v 5000K 13,011 Lm HL16-170-50-EX-U-GR HL16 166 Watts 120-277v 5000K 19,058 Lm Dissipates heat efficiently CRI: >70 Type V distribution Power Factor: >.95 5-Year Warranty 347-480 High Voltage HL06-055-50-EX-48-GR HL06 53 Watts 347-480v 5000K 6,061 Lm HL12-104-50-EX-48-GR HL12 106 Watts 347-480v 5000K 13,011 Lm HL16-170-50-EX-48-GR HL16 166 Watts 347-480v 5000K 19,058 Lm ACCESS IES SELL SHEET PRODUCT LINK PRINT VIDEO PRODUCT ORDER SELECTION If button is inactive, the link may be in revision. HL G Series Type-Watts Kelvin Voltage Color Mounting Options HL 06-055 50-5000K (Std) U-120-277 G-Grey (Std) PM-Pendant Refer to Complete List of Options 12-104 40-4000K 48-347-480 CH-Closed Hook on Page 2. 16-170 35-3500K Insert the Item Code(s) Above. The mini Beast HazLoc CS 11.22.17
hazloclow BAY THE HazLoc LOW BAY MINI BEAST 120-277 Universal & 347-480 High Voltage MOUNTING SYSTEMS Pendant Mount Pendant with Hook Mount WEIGHT RANGE HL06, HL12 & HL16 19 lbs. ARRA Buy American American Recovery & Reinvestment Act SIDE VIEW 14.0 TOP VIEW 3.56 14.0 Dia OPTIONS & ACCESSORIES Safety Cables C5 5 foot - 3/32" Safety Cable - Reinforced Loops C10 10 foot - 3/32" Safety Cable - Reinforced Loops Power Cords & Plugs - Factory Installed CD6 6 ft Cord - 347-480 vac (No Plug, 3 wire) CD12 12 ft Cord - 347-480 vac (No Plug, 3 wire) CDX Customer Specified Cord length - 347-480 vac HLCD5-3 3 ft cord- 5 wire for dimming - 347-480 vac HLCD5-X Customer specified cord length - 5 wire for dimming - 347-480 vac Mounting Options - Hooks & Pendants PHS Pendant Hook with Safety Clip PHS-PM3 3" Pendant with Hook with Safety Clip PHS-PM6 6" Pendant with Hook with Safety Clip PHS-PM12 12" Pendant with Hook with Safety Clip PHS-PM18 18" Pendant with Hook with Safety Clip PHS-PM24 24" Pendant with Hook with Safety Clip PHL Pendant Hook Loop PM3 3" Galvanized Pendant - Threaded ITEM CODE PM6 PM12 PM18 PM24 Colors GR DESCRIPTION 6" Galvanized Pendant - Threaded 12" Galvanized Pendant - Threaded 18" Galvanized Pendant - Threaded 24" Galvanized Pendant - Threaded Gray - Standard on Haz Loc
SPECIFICATIONS hazloc LIGHTING 120, 277 & 480 Voltage KEY FEATURES Three Models: 120 vac, 277 vac & 480 vac IP 68 rated for wet outdoor locations.. AC Driver-less system capable of operating from -65 C to 100 C Die Cast aluminum fixture for LED heat dissipation and thermal control. Warm white (3000K) and Cool white (5000K) Groups A, B, C & D Flammable Gases & Vapors AMBIENT TEMPERATURE 100 C / 212 F I Groups F & G Combustible Dusts Explosion-Proof LED Low Bay Light Fixtures (, Div I and I, Div I) designed for use in Hazardous Locations for applications including Oil Refineries, Petrochemical Plants, Painting Facilities and Offshore Oil & Natural Gas Platforms. HT11-120-50-120-X Guard 120 120 Watts 120v 5000K 12,000 Lm HT11-120-50-277-X Guard 120 120 Watts 277v 5,000K 12,000 Lm HT11-120-50-480-X Guard 120 120 Watts 480v 5000K 12,000 Lm HT11-140-50-120-X Guard 140 140 Watts 120v 5,000K 14,000 Lm HT11-140-50-277-X Guard 140 140 Watts 277v 5000K 14,000 Lm HT11-140-50-480-X Guard 140 140 Watts 480v 5,000K 14,000 Lm Rated Life - 100,000+ hours 100 Lumens per watt 5000K Power Factor: >.95 5-Year Warranty ACCESS SELL SHEET IES PRODUCT LINK PRINT VIDEO If button is inactive, the link may be in revision. PRODUCT ORDER SELECTION HT11 G Series Type-Watts Kelvin Voltage Color Mounting Options HT11 120-120 watts 50-5000K (Std) 120-277v G-Grey (Std) Refer to Complete List of Mounting & Options listed on Page 2. 140-140 watts 30-3000K 277-277v Insert the Item Code(s) Above. 347-480v HZ The Guard CS 11.22.17
120, 277 & 480 Voltage MOUNTING SYSTEMS hazloc LIGHTING Pendant Mount Hanging Mount Wall Mount Ceiling Mount Stanchion Mount 25 Stanchion Mount 90 Portable Mount DIMENSIONS 11.42 11 WEIGHT RANGE HT11 21.2 lbs. 6.1 9.59 OPTIONS & ACCESSORIES Mounting Options AB Adjustable Bracket (Hanging & Wall Mount) CM Ceiling Mount SM25 Stanchion Mount 25 SM90 Stanchion Mount 90 PM Pendant Mount PORT Portable Mount
SPECIFICATIONS hazloc LIGHTING 120, 277 & 480 Voltage KEY FEATURES Three Models: 120 vac, 277 vac & 480 vac IP 68 rated for wet outdoor locations.. AC Driver-less system capable of operating from -65 C to 100 C Die Cast aluminum fixture for LED heat dissipation and thermal control. Groups A, B, C & D Flammable Gases & Vapors AMBIENT TEMPERATURE 100 C / 212 F Explosion-Proof LED Low Bay Light Fixtures (, Div I and I, Div I) designed for use in Hazardous Locations for applications including Oil Refineries, Petrochemical Plants, Painting Facilities and Offshore Oil & Natural Gas Platforms. HTRT-040-50-120 Attendant-40 40 Watts 120v 5,000K 4,000 Lm HTRT-040-50-277 Attendant-40 40 Watts 277v 5,000K 4,000 Lm HTRT-040-50-480 Attendant-40 40 Watts 480v 5,000K 4,000 Lm Rated Life - 100,000+ hours 5000K Power Factor: >.95 5-Year Warranty TOP MOUNT DEMINSIONS 5.1 8 WEIGHT RANGE HTRT 8.2 lbs. ACCESS 7 SIDE MOUNT DEMINSIONS SELL SHEET IES PRODUCT LINK 5.1 10.41 PRINT VIDEO PRODUCT ORDER SELECTION If button is inactive, the link may be in revision. HTRT G Series Type-Watts Kelvin Voltage Color Mounting Options HTRT 040-40 watts 50-5000K (Std) 120 277 G-Grey (Std) Refer to Complete List of Mounting & Options listed on Page 2. 080-80 watts 30-3000K 480 Insert the Item Code(s) Above. HZ The Attendant CS 11.22.17
120, 277 & 480 Voltage MOUNTING SYSTEMS hazloc LIGHTING Pendant Mount Hanging Mount Wall Mount Ceiling Mount Side Mount Stanchion Mount 90 Stanchion Mount 25 Reflector Hoods 10 W 13 W Portable Adjustable System OPTIONS & ACCESSORIES Accessory Options R Reflector PAS Portable Mobile Lighting system Mounting Options AB Adjustable Bracket - Wall & Hanging SM25 Stanchion Mount 25 SM90 Stanchion Mount 90 PM Pendant Mount CM Ceiling Mount
SPECIFICATIONS hazloclighting 120-277 Universal Voltage Groups A, B, C & D Flammable Gases & Vapors AMBIENT TEMPERATURE 50 C / 122 F KEY FEATURES Die-cast aluminum fixture housing with powder-coated finish for superior environmental protection. 4 mm clear tempered glass lens with 95% light transmission. Optically designed reflector for wide area illumination. Meanwell HLG Series Drivers. IP 68 rated for wet outdoor locations. Explosion-Proof LED Light Fixture (, Div 2) designed for use in Hazardous Locations for applications requiring LED Flood Lights & LED High Bay Lights an extremely cost effective LED light fixture for industrial and commercial environments. HCS8-040-40-U-X Warden 8 28 Watts 120-277v 5000K 3,132 Lm HCS12-100-40-U-X Warden 12 100 Watts 120-277v 5000K 11,701 Lm HCS16-185-40-U-X Warden 16 185 Watts 120-277v 5000K 21,313 Lm DIMENSIONS 8 12 16 WEIGHT RANGE HCS 8 8.8 lbs. HCS 12 18.8 lbs. HZCS 16 27.6 lbs. Rated Life - 100,000+ hours RoHS Compliant CRI: >70 Surge protection Power Factor: >.98 5-Year Warranty ACCESS SELL SHEET 8 12 IES PRODUCT LINK HCS 8 HCS 12 16 PRINT VIDEO PRODUCT ORDER SELECTION HCS 16 If button is inactive, the link may be in revision. U G Series Type-Watts Kelvin Voltage Color Mounting Options HCS 8 040-28 watts 50-5000K (Std) U-120-277 G Gray (Std) Refer to Complete List of Mounting & Options listed on Page 2. HCS 12 100-100 watts 40-4000K listed on Page 2. Insert the Item Code(s) Above. HCS 16 185-185 watts 30-3000K HZ The Warden CS 11.22.17
120-277 Universal Voltage hazloclighting MOUNTING SYSTEMS Ceiling Mount Drop Mount Pendant Mount Knockle Mount Universal Bracket Arm Mount 45 Arm Mount 90 Pole Mounts OPTIONS & ACCESSORIES Add on Metal Components - Hoods & Cages WGHB Aluminum Protective Wire Guard Mounting Options PHL Pendant Hook Loop (Standard) UB Universal Bracket DM Drop Mount WB90 Wall Mount 90 WB45 Wall Mount 25 POM Pole Mount CM Ceiling mount KM Knuckle Mount AB Arm Bracket AB45 Arm Bracket 45 AB90 Arm Bracket 90
SPECIFICATIONS hazloclinear LIGHTING KEY FEATURES Copper Free aluminum fixture for LED heat dissipation and thermal control. Excellent Lighting Efficiency up to 130 Lumens per Watt. 2 LED arrays - 40 watts (2 ft.) & 80 watts (4 ft.). Meanwell Driver. 120-277 & 347-480 Voltage Groups A, B, C & D Flammable Gases & Vapors AMBIENT TEMPERATURE 50 C / 122 F I Division 1 Groups E, F & G Combustible Dusts Slim profile, light weight, Explosion-Proof LED Linear Fixtures designed for use in Hazardous Locations. Flexible mounting applications: Ceiling Mount, Wall Mount, Hanging Chain and Stanchion (Pole) Mount a cost effective solution for industrial and commercial use. HNL2-040-50-U-X Protector 2 40 Watts 120-277v 5000K 5,450 Lm HNL2-040-50-48-X Protector 2 40 Watts 347-480v 5000K 5,450 Lm HNL4-040-50-U-X Protector 4 80 Watts 120-277v 5000K 10,400 Lm HNL4-040-50-48-X Protector 4 80 Watts 347-480v 5000K 10,400 Lm Rated Life - 100,000+ hours NEMA 6/6P CRI: >70 5000K Power Factor: >.95 5-Year Warranty ACCESS SELL SHEET IES PRODUCT LINK PRINT VIDEO PRODUCT ORDER SELECTION If button is inactive, the link may be in revision. 50 NA Series Type-Watts Kelvin Voltage Color Mounting Options HNL2 040-40 watts 50-5000K (Std) 120-227 NA-Nat. Aluminum Refer to Complete List of Mounting & Options listed on Page 2. HNL4 080-80 watts 347-480 (Std) Insert the Item Code(s) Above. HZ The Protector 11.22.17
120-277 & 347-480 Voltage MOUNTING SYSTEMS hazloclinear LIGHTING Wall Mount Ceiling Mount Hanging Mount Pendant Mount Pole Mount WEIGHT RANGE HNL2 12.8 lbs. HNL4 18.1 lbs. Protector 2 Dimensions 23.625 5 7.56 Protector 4 Dimensions 47.2 5 OPTIONS & ACCESSORIES Mounting Options WM Wall Mount (Standard) CM Ceiling Mount HM Hanging Mount Eye Bolts PM3 3" Galvanized Pendant - Threaded POM Pendant Mount SM Stanchion Mount 25
SPECIFICATIONS hazloc LIGHTING 120-277 Universal Voltage KEY FEATURES Copper-free, die-cast aluminum fixture housing for superior environmental protection. Beam Angle (110 degrees) for wide area illumination. Separate Fixture and Driver compartments for improved heat dissipation and thermal control. Excellent Lighting Efficiency up to 150 Lumens per Watt. Groups A, B, C & D Flammable Gases & Vapors I Division 1 Groups E, F & G Combustible Dusts I Groups F & G Combustible Dusts I I Division 1 Easily ignitable fibers or materials producing combustible flyings are handled, manufactured or used. AMBIENT TEMPERATURE 55 C / 131 F Explosion-Proof LED Light Fixture designed for use in several Hazardous Locations for applications requiring LED Low Bay Lights, Wall Mounted Floods and Stanchion (Pole) mounted Area Lights an extremely cost effective LED light fixture for industrial and commercial environments. HNRO-042-50-U-X Sentry 42 42 Watts 120-277v 5000K 6,498 Lm HNRO-065-50-U-X Sentry 65 65 Watts 120-277v 5000K 9,891 Lm DIMENSIONS 10.2 WEIGHT RANGE 9.26 lbs. CSA C22.2 No. 250.0-08 CRI: >70 Power Factor: >.95 Optical Pattern: 110 5-Year Warranty ACCESS SELL SHEET 5.9 IES PRODUCT LINK PRINT VIDEO PRODUCT ORDER SELECTION If button is inactive, the link may be in revision. HNRO 50 G Series Type-Watts Kelvin Voltage Color Mounting Options HNRO 042-42 watts 50-5000K (Std) 120-277 G-Gray (Std) Refer to Complete List of Mounting & Options listed on Page 2. 065-65 watts Insert the Item Code(s) Above. HZ The Sentry 11.22.17
120-277 Universal Voltage hazloc LIGHTING MOUNTING SYSTEMS Bracket Mount Ceiling Mount Pendant Mount Wire Guard Stanchion Mount 90 Stanchion Mount 25 Wall Mount 90 Wall Mount 25 OPTIONS & ACCESSORIES Add on Metal Components WGHB Aluminum Protective Wire Guard Mounting Options PM Pendant Mount BM Bracket Mount (Std) WM25 Wall mount 25 WM90 Wall mount 90 CM Ceiling mount SM25 Stanchion mount 25 SM90 Stanchion mount 90
SPECIFICATIONS hazloclighting 120-277 Universal Voltage Explosion Proof LED Emergency Exit Sign The Director 10W explosion proof LED emergency exit sign with halogen bug eyes features reliable illumination and notification in, hazardous locations. Advanced Diagnostics Self Testing Short Circuit Proof Maintenance Free Battery Back-up Tamper Resistant Groups A, B, C & D Flammable Gases & Vapors T3A Temperature Rating Maximum Temperature 180 C / 356 F Specifications Lamp Types: LED (Exit Sign), MR16 Halogen Bug Eyes Input Voltage: 120/277V AC @ 60Hz Lamp Voltage: 12V DC Watts: 10W (Max 29W) [Unit]; 12W (Max 24W) [Lamps] Current: 0.30/0.08A (Max), 0.13/0.05A (Standby) Battery Type: Sealed, Maintenance-free Nickel Cadmium Battery Runtime: 90 Minutes ORDER NUMBER HEL10-010-40-U-X NAME The Director Advanced Diagnostic Circuitry Circuitry is programmed to ensure the combination unit s readiness and reliability by continuously monitoring all critical functions. The diagnostic display is located inside, securely and not visible to the general public. Self Testing schedule is every 30 seconds every 30 days, 30 minutes every 60 days and 90 minutes annually. DIMENSIONS & FEATURES ACCESS Back Panel Knockouts SELL SHEET IES PRODUCT LINK 14.5 W x 12.7 H x 3.5 1/2 Conduit Entries Sides & Top Weight: 20 lbs PRINT VIDEO If button is inactive, the link may be in revision. The Director CS 11.22.17
120-277 Universal Voltage hazloclighting DETAILED INFORMATION The Director 10W explosion proof LED emergency exit sign with halogen bug eyes features reliable illumination and notification in, hazardous locations. This unit supports 120-277V AC input voltages (29W max) and 12V DC output (24W max). The bug eye lamps are equipped with MR16 halogen bulbs. In the event of power outage, this unit will continue to function for 90 minutes via a sealed, maintenancefree nickel cadmium battery. A self-testing mechanism automates monitoring of critical functions within the unit. This hazardous area LED emergency exit sign is suitable for, rated facilities. During operation, the unit features 120-227V AC input voltages (12V DC output for the lamp). The unit consumes 10 watts (max 29W), while the lamp consumes 12 watts (max 24W). Should power outage occur, the unit may revert to a nickel cadmium battery for power, which offers a runtime of 90 minutes. A low voltage battery disconnect built into the device preserves the solid-state battery and charger. This unit is constructed of cast aluminum with a sturdy polycarbonate cover and stainless steel, tamper-resistant screws. Advanced Diagnostic circuitry is available in the HAL-EMG-EXT-3L-10W. This circuitry is programmed to ensure the combination unit s readiness and reliability by continuously monitoring every critical function of the unit. If a problem occurs, a single Service Required indicator illuminates immediately. A detailed diagnostic display that will further indicate the nature of the fault is located on the inside of the exit sign, out of sight from the general public. The self test will test the unit for a minimum of 30 seconds every 30 days, 30 minutes every 60 days and 90 minutes annually. LED Benefits: Unlike gas burning and arc type lamps that have glass bulbs, LEDs have no filaments or fragile housings to break during operation and/or transportation. Instead of heating a small filament or using a combination of gases to produce light, light emitting diodes (LEDs) use semi-conductive materials that illuminate when electric current is applied, providing instant illumination with no warm up or cool down time before re-striking. Because there is no warm up period, this light can be cycled on and off with no reduction in lamp life. LED lights run at significantly cooler temperatures than traditional metal halide and high pressure sodium lights and contain no harmful gases, vapors, or mercury, making them both safer and more energy efficient. No extra energy is wasted in cooling enclosed work areas due to external heat emissions from bulb type lights, and the operator risks associated with traditional lighting methods, such as accidental burns and exposure to hazardous substances contained in the glass bulbs, are eliminated. In addition, LEDs are also safer for the environment as they are 100% recyclable, which eliminates the need for costly special disposal services required with traditional gas burning and arc type lamps. Mount: This unit is designed for wall mounts via a 1/2 electrical conduit entry on both sides and at the top. Applications: Manufacturing plants, chemical plants, paint shops, oil refineries, gas stations, industrial facilities, warehouses, processing plants and other, hazardous locations.