HAZLUX INDUSTRIAL INDUCTION LIGHTING

Similar documents
Applications. Standard Materials

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

LMV Series W Low Profile - Medium Base

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

DMV Series W For Combustible Dusts

EVLPF Series Compact Fluorescent

Overview of Hazardous Locations as They Relate to Solenoid Valves

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

50W Explosion Proof LED Light - C1D2, C2D1 - Replacement for 150W Metal Halide - Globe/Guard

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

N2MVF Series Compact Fluorescent

LED hazardous lighting catalog

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

25W Explosion Proof Surface Mount LED Light - C1D1-2 - C2D1-2 - Aluminum Frame V AC

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Rating. Class I Div II

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

120W Hazardous Location LED Fixture V DC - Modbus TCP/IP - Network Controlled - Dimmable

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

150W Explosion Proof LED Flood Light - Surface Mount Lumens - C1D V AC

LIGHTING in Hazardous (Classified) Locations

120W Explosion Proof Signal Light w/ Audible Alarm - C1D1 - (2) Colored LED Lamps - 55 Horn Tones

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

Engineering Safety & Productivity. Champ FMV LED Series Floodlight Fixtures Leading the way in LED technology for harsh and hazardous area usage

Lighting for Hazardous & Severe Environments

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

COMPACT SIZE INTRODUCTION & LOGIC

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

ARRAN LED LED FLOODLIGHT. Standard Specification. Features

HL-2449_flg:8 pager 6/17/10 11:19 AM Page 1 Tear Drop LED Series

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

300W EXP LED Light - 35,000 Lm - 3' Cart Mount - Quick Change Mount - C1D1-100' 16/3 SOOW- EXP Plug

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

Table 500-3(d) Identification Numbers. Maximum Identification

REFRACTOPACK. Corrosion resistant construction allows this luminaire to be installed in corrosive and marine outdoor applications.

UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating

SIMPLIFIED LIGHTING. TRUSTED PROTECTION. CODE MASTER LED LUMINAIRES CLASS I, DIVISION 1

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network

Explosion Proof LED String Lights - 5 Hand Lamps - Class 1 & Class 2

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

150 Watt Explosion Proof LED Light - 5' Tall Base Stand Mount - 24 Inch Stand - Class I Div 1 C&D

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp

FX5 Series Explosion-Proof Electric Air Heaters

Dialight LED Area Light. Product Brochure - UL

100W Portable Explosion Proof LED Light - (2) LED Lamps - Non-Spark Aluminum Base - Inline Switch

REDUCED PROFILE INTRODUCTION

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

56W Vapor Proof LED Fixture V Dimmable - DALI Network lms - IP67 - Outdoor Applications

Description. Applications

SECTION LIGHTING

EXH Series Explosionproof Electric Air Heaters

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

UTILITY LIGHT INTRODUCTION

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

Champ-Pak TM Wall Pack & Floodlight Luminaires Hazardous and Non-Hazardous

SECTION INTERIOR LIGHTING

56W Hazardous Location LED Light - C1D2 - Corrosion Resistant for Marine - Dimmable - DALI Network

VAPORGARD Incandescent Luminaires

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X

An Eaton Intelligent Power solution. Champ VMV Connected lighting for hazardous areas

SECTION INTERIOR LIGHTING

Circulation Heaters Selection Guidelines

Circulation Heaters Selection Guidelines

HID lighting for hazardous areas Champ HID floodlighting. Champ floodlights. HID floodlighting for hazardous areas

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

HOLOPHANE. Vector Luminaire. Optimum visibility. Improved highway safety. Outstanding visibility in critical security applications HL /98

LED lighting for light industrial areas IHB series high bay LED luminaires. IHB series. High bay LED luminaires for light industrial areas

HLA Series Hazardous Location Fan Forced Unit Heater

High Mast Series HMAO HMSC

E THANOL AND B IODIESEL P LANT L IGHTING S OLUTIONS

Transcription:

HAZLUX INDUSTRIAL INDUCTION LIGHTING

Thomas & Betts is committed to delivering high quality industrial lighting systems designed, tested and certified for use in hazardous locations and adverse environment conditions. You can rely on Hazlux to safely provide light where you need it even under the harshest indoor and outdoor conditions. If safety, labor reduction, quality and reliability are your priorities; consider Hazlux lighting. Keeping our commitment to the industrial markets, T&B is introducing an energy efficient, long life and extreme temperature rated induction lighting system within our Hazlux hazardous lighting products. Longest Life-Energy Efficient Induction Lighting Available in the Market Hazlux has integrated a new induction lighting technology into its explosion-proof graded luminaires to create one of the longest lasting energy efficient lighting systems on the market. With a 100,000-hour rated life span, this system yields over twice the life and costs significantly less in maintenance than technologies like LED, HID, and fluorescent lighting. In addition, by selecting the cold weather feature during the order process, these luminaires are able to operate in -50 C temperatures. T&B s new Hazlux induction lighting system is the way to go in your facility. Advantages of Hazlux Induction Lighting Reduced power consumption of 50% - 70% Ultra-long life - up to 100,000 hours Excellent color rendering index (CRI) of 80+ Instant On & Restrike (with no flickering) Rated for extreme temperatures of -40 C to 40 C (-40 F to 104 F) Operates in temperatures down to -50 C (-58 F) using our Cold Weather Circuit option Excellent lumen output with minimal depreciation Suitable for high-vibration applications Total harmonic distortion of less than 10% No interference with external instrumentation Universal voltage (120/277V) standard, 480/347V available, 50/60 Hz 5,000 Kelvin standard (others available) Convert existing luminaires easily with Quick-Pole Assembly and HazVertor Ring Area Lighting Hazlux 3 Low Wattage...7 General Applications Class 1, Div. 2 Groups A, B, C, D Lamp wattage: 35-100 watt 100K Hour lamp life Selection of Globes, Guards, & Reflectors Area Lighting Hazlux 3 High Wattage...12 High-Bay / Extreme applications Class 1, Div. 2 Groups A, B, C, D Lamp Wattage: 165 watt 65K Hour lamp life Single selection of Globe, Guard, & Reflector Area Lighting Hazlux 5 Induction...17 Explosion Proof Environments Class 1, Div. 1 Groups C, D 100K Hour lamp life Lamp wattage: 35-85 watt Accessory: Quick Pole Assembly...22 Allows single person lowering of luminaire without the need for ladders Various mounting options Various heights available

Hazlux 3 About Induction Lighting Induction lighting is similar to fluorescent lighting, in that they both use phosphors to fluoresce and create light. While a fluorescent lamp uses filaments to create an electric arc, the induction lamp is wireless and excites the phosphors via high-frequency induction energy (created by the induction coil located in the middle of the bulb). Usually the filaments are the weak spot for the life of the lamp causing the whole lamp to become inoperative once they burnout. The induction lamp doesn t have filaments and has a much longer life. The light emitted by the induction lamp also has a high Color Rendering Index (CRI). This allows it to accurately mimic sunlight by showing a full spectrum of colors and provide a high Kelvin temperature that ensures crisp contrast on your working surface. In addition, the lack of filaments makes this technology very resilient to high vibration environments. Light output from a given luminaire declines over time due to the deterioration of the elements that comprise the lighting system (for example, within incandescent lamps, the filament is depleted and tungsten particles accumulate on the wall of the bulb); this is typically known as Lumen Depreciation. For industrial applications, it is common to replace the lamp when the output of the bulb is reduced to 65% of the initial rated lumen output. The chart below shows that induction lighting has the longest life span among competing technologies in today s industrial environments. To help put a 100,000-hour lifespan in perspective if you operated the lamp continuously, it would burn for over 11 years before needing to be replaced. This provides cost savings for facilities requring a reduction in continuous operation and maintenance. Visible Light UV Light Glass envelope/bulb Phospor coating inside envelope/bulb Intert gas fill Induction Coil Magnetic Field Reentrant glass tube Mercury Amalgam Base/heat sink Wires to connect ballast Lighting Technologies Performance Comparison INDUCTION LED METAL HALIDE HIGH PRESSURE SODIUM LAMP LIFE HRS 100k 30k - 50k 10k - 15k 15k - 24k LIGHTING EFFICIENCY Lm/Wt 65-90 90-120 60-110 60-120 CRI > 80 > 70 > 70 > 20 S/P RATIO 1.46-2.25 1.96 1.49 0.62 COLOR TEMPERATURE Full Range Full Range Limited Range Limited Range HOT RESTART INSTANT INSTANT DELAY DELAY MERCURY Low N/A Low - High Low - Medium % rated lumen output 100 95 90 85 80 75 70 65 60 55 50 Lamp Replacement { at 65% / EOL METAL HALIDE LED HIGH PRESSURE SODIUM INDUCTION 10,000 20,000 40,000 60,000 80,000 100,000 HOURS OF OPERATION

4 Hazlux Induction Lighting Greater Vision Clarity Per Watt = Increased Safety Induction Lighting It's the quality of light not the wattage or brightness that counts when it comes to visual acuity. Induction lighting produces breakthrough light quality because it was engineered according to the latest understanding of how the human eye processes visual stimuli. With it you can use fewer luminaires and have the same work-surface visual acuity. Induction lighting produces vision-friendly light, offering more clarity per watt. Transmission of visual stimuli from the eye to the brain depends on efficient functioning of the retina s rods and cones. Rods are excellent for seeing at night (scotopic vision), while cones perform at brighter levels to see colors (photopic vision). Induction lighting is designed to allow the best possible interaction between the rods and cones, assuring optimal scotopic/photopic (S/P) balance. High Pressure Sodium Scoptic/Photopic (S/P) Ratio SUN + SKY (CIE D65 ILLUMINANT) SUN (CIE D65 ILLUMINANT) 6500K INDUCTION LAMP 5000K INDUCTION LAMP 4100K INDUCTION LAMP METAL HALIDE (NA/SC) 3500K INDUCTION LAMP INCANDESCENT (2850K) WHITE HIGH PRESSURE SODIUM (50W) WARM WHITE FLUORESCENT HIGH PRESSURE SODIUM (50W) HIGH PRESSURE SODIUM (35W) LOW PRESSURE SODIUM (SOX) 2.47 2.28 2.25 1.96 1.62 1.49 1.46 1.41 1.14 1.00 0.62 0.40.035 0 0.5 1.0 1.5 2.0 2.5 Chart calculations by Berkley Labs - actual selection of induction lamp wattage and type will vary with installation and user requirement. Long Life Span Minimizes Energy and Maintenance Costs Eliminates the need for expensive HID options, such as quartz auxiliary lamps or instant restrike Increases efficiency by decreasing shutdown time Operating Cost Comparison Between Induction and High Pressure Sodium Technology Operating Cost Comparison Reduces the number of times necessary to de-energize an entire circuit of lights for maintenance in hazardous locations Reduces expensive rental costs of scissor lifts or bucket trucks Re-Lamping Cost Comparison Operating Cost 85W Induction 150W HPS Re-Lamping Cost 85W Induction 150W HPS Luminaire Wattage (lamp + ballast) x 89.25 180 5-Year Annual Burn Hours 43,800 43,800 Annual Burn Hours (/1000) x 8.760 8.760 Lamp Useful Hours 100,000 20,000 # of Luminaires x 550 550 # of Re-lampings within 5 years 0.438 2.19 Total Annual Kilowatts 430,006 867,240 Lamp Replacement Cost $0 $15.00 Kilowatt Rate ($/kilowatt*hour) x 0.135 0.135 Labor Replacement Cost $0 $30.00 Annual Cost $58,050.88 $117,077.40 # of Luminaires 550 550 5-Year Cost $290,254.39 $585,387.00 5-Year Re-Lamping Cost $0 $54,202.50 Total 5-Year Cost $290,254.39 $639,589.50 Total 5-Year Savings $349,335.11 Note: Kilowatts based on 5-year average. Check with local utility for rebate program availability. Cost calculator on www.tnb.com allows you to calculate your savings when using our induction luminaire. For government tax rebates incentives please visit local state information sites.

Hazlux Induction Lighting 5 Hazardous Locations Hazardous Location An area where the possibility of explosion and fire is created by the presence of flammable gases, vapors, dust, fibers or flyings. Class I Gas Class I NEC 500.5(B) Class I locations are those in which flammable gases, flammable liquid-produced vapors or combustible liquid-produced vapors are or may be present in the air in quantities sufficient to produce explosive or ignitable mixtures. Typical Class I Locations: Petroleum refineries and gasoline storage and dispensing areas Industrial firms that use flammable liquids in dip tanks for parts cleaning or other operations Petrochemical companies that manufacture chemicals from gas and oil Dry cleaning plants where vapors from cleaning fluids can be present Companies that have spraying areas where they coat products with paint or plastics Aircraft hangars and fuel serving areas Utility gas plants and operations involving storage and handling of liquified petroleum gas or natural gas Class II Dust Class II NEC 500.5(C) Class II locations are those that are hazardous because of the presence of combustible dust. Typical Class II Locations: Grain elevators, flour and feed mills Plants that manufacture, use or store magnesium or aluminum powders Plants that have chemical or metallurgical processes: producers of plastics, medicines and fireworks, etc. Producers of starch or candies Spice-grinding plants, sugar plants and cocoa plants Coal preparation plants and other carbon handling or processing areas Class III Fibers Class III NEC 500.5(D) Class III locations are those that are hazardous because of the presence of easily ignitable fibers or where materials producing combustible flyings are handled, manufactured or used, but in which such fibers/flyings are not likely to be in suspension in the air in quantities sufficient to produce ignitable mixtures. Typical Class III Locations: Textile mills, cotton gins, cotton seed mills and flax processing plants Any plant that shapes, pulverizes or cuts wood and creates sawdust or flyings Note: Fibers and flyings are not likely to be suspended in the air but can collect around machinery or on lighting luminaires and where heat, a spark or hot metal can ignite them. Division 1 Normally Hazardous Division 1 Hazardous gases or dusts are present under normal operation conditions or during frequent repair and maintenance activity. Groups A, B, C, D Groups A, B, C and D (NEC 500.6 (A)) The gases and vapors of Class I locations are broken into four groups by the code A, B, C and D. These materials are grouped according to the ignition temperature of the substance, its explosion pressure and other flammable characteristics. Groups E, F, G Groups E, F, G (NEC 500.6 (B)) Class II dust locations groups E, F and G are classified according to the ignition temperature and the conductivity of the hazardous substance. Division 2 Not Normally Hazardous Division 2 Hazardous gases or dusts are not present under normal operating conditions. Articles 500 through 505 (2011 NEC ) Explains in detail the requirements for the installation of wiring or electrical equipment in hazardous locations. These articles along with other applicable regulations, local governing inspection authorities, insurance representatives and qualified engineering/technical assistance should be your guides to the installation of wiring or electrical equipment in any hazardous or potentially hazardous location. Note: These are simplified definitions complete data is in the referenced 2011 NEC. NEC and National Electrical Code are registered trademarks of the National Fire Protection Association, Inc.

6 Four-Step Method for Selecting Lighting Luminaires for Hazardous Locations 1. Select a luminaire that meets your Class, Division and Group requirements. Typically: Example: Class I, Division 2, Group D Class II, Division 1, Group G Say your environment has Propane gas that is always present. According to NEC Article 500 sections, you ll need a Class 1, Division 1, Group D luminaire (which would be our Hazlux 5 series). 2. Determine the T-Number for your selected luminaire. Be sure it is for the specific wattage, ballast housing, optical assembly and ambient temperature. Use the published information in this catalog or in Hazlux product brochures Example: All of our Hazlux 5 series induction luminaires have a T6 rating (max. luminaire spot temperature of 85 C). 3. Determine the Maximum Allowable Temperature for the hazardous materials involved. Class I Gas: Ignition Temperature for the Specific Gas (from pp. I-4 I-6 of this catalog or from NFPA497M) Class II Dust: Group E...200 C Group F...200 C Group G...165 C Or ignition temperature of dust if lower Above from NEC Table 500-3(F) Example: The auto-ignition temperature of propane is 470 C which will require a minimum T-Code of T1. 4. Compare T-Number (from Step 2) to Maximum Allowable Temperature (from Step 3). If T-Number is cooler than the Maximum Allowable Temperature, the selected luminaire is suitable. If T-Number is hotter than the Maximum Allowable Temperature, the selected luminaire is not suitable. Example: Since the T-Code of the luminaire (T6, 85 C) is cooler than the auto-ignition temperature of the gas (T1, 470 C) then the Hazlux 5 induction luminaire is the appropriate choice. T-Number Table CLASS I, II, DIV. 1, 2 T-NUMBER MAX. TEMP. (IN C) T1 450 T2 300 T2A 280 T2B 260 T2C 230 T2D 215 T3 200 T3A 180 T3B 165 T3C 160 T4 135 T4A 120 T5 100 T6 85

Hazlux 3 Induction Low Wattage 7 Now You Can Use the Longest-Life Lamp Available on the Market. Thomas & Betts has recently added induction lighting technology to our hazardous lighting offering. This technology allows us to serve our customers looking to improve energy efficiency and reduce their hazardous lighting maintenance costs, all while operating in extreme weather temperatures. With a white color output, minimal lumen depreciation, and a rated lifespan of 100,000+ hours, T&B s new Hazlux induction lighting systems are the way to go in your facility. I sure don t envy the person who has to change these lamps! Features include: 100,000+ hour lamp life Reduced maintenance/re-lamp operations Instant On/Instant Restrike Automatic switch-off in case of failure 5000K CCT Standard Exceptional energy efficiency -40 C to 40 C ambient operating range (temperatures down to -50 C available with our Cold Weather Circuit option) Retrofits into existing Hazlux 3 applications RFI-approved (FCC part 18 reference luminaire) Here s how you save maintenance costs with Hazlux Induction Lighting: Eliminates the need for expensive HID options such as Quartz Auxiliary Lamps or Instant Restrike Reduces risks to installers performing maintenance in hard-to-reach places Increases efficiency by decreasing machine shutdown time Reduces number of times necessary to de-energize entire circuit of lights for maintenance in hazardous locations Lowers cost of expensive rental of scissor lifts or bucket trucks Hazlux 3 Induction Certification Guide WATTS AMBIENT TEMP ( C) CLASS I, DIVISION 2 GROUPS A, B, C, D TEMPERATURE CODE CLASS II, DIVISION 1 SIMULTANEOUS CLASS I, DIVISION 2 AND CLASS II, DIVISION 1 UL 1598A MARINE NEMA 4X* SUPPLY WIRE TEMP. RATING ( C) 35 40 T3B T6 T3 Yes Yes 90 55 40 T3B T6 T3 Yes Yes 90 85 40 T2A T6 T2A Yes Yes 90 100 40 T2A T6 T2A Yes Yes 90 Hazlux Induction Lighting reduces the cost of expensive maintenance of industrial lighting in hazardous locations. Note: 1. Simultaneous presence applications: Some Hazlux 3 luminaires are UL Listed for simultaneous presence of gas and dust. Contact Hazlux for specific information. 2. Tuff-Skin Coated Optics: Many Hazlux 3 luminaires are UL Listed with Tuff-Skin (silicone) coating on glass optics. Contact Hazlux for specific information. 3. For UL and CSA Certification Information on other ambient temperatures and luminaire configurations, consult the factory. 4. Tuff-Skin is a registered trademark of Thomas Manufacturing Corp.

8 Hazlux 3 Induction Low Wattage Hazardous Area Lighting Class I, Division 2 Luminaire Assembly Guide Mounting Style HazVertor Adapter Ring Rigid or Flexible Pendant Cone-Top Pendant Ceiling Mount Wall Mount 25 Angle Stanchion Straight Stanchion Ballast Tank R-Housing Globe or Refractor Heat-Resistant Globe Refractor Globe Refractor Glass Guard Polymeric Guard Cast Guard Steel Wire Guard Reflectors* Standard Dome 30 Angle Deflector Deep Dome * Reflectors are shipped uninstalled and separately.

Hazlux 3 Induction Low Wattage 9 Hazardous Area Lighting Class I, Division 2 Catalog Numbering System DI Ø 03 E UN R R1 A2 - T - E F C 1 2 3 4 5 6 7 8 9 10 11 12 1 Luminaire Series DI = Hazlux 3 Induction Series 2 Starter Circuit/Quartz Options Ø = Standard Luminaire (Without Options) C = Cold Weather Circuit (-50 C) 3 Lamp Wattage 03 = 35 Watts 05 = 55 Watts 08 = 85 Watts 10 = 100 Watts 4 Ballast Circuit E = Electronic Ballast 5 Voltage/Frequency UN = 120 to 277 Vac, 50/60 Hz 48 = 480 Vac, 60 Hz 34 = 347 Vac, 60 Hz 6 Ballast Housing Style R = R-Housing I = R-Housing with Stainless Steel Inserts 7 Optical Assembly Options Globes are available only for 35W and 55W R1 = 7 3 4" Refractor Globe, Type I R3 = 7 3 4" Refractor Globe, Type III R5 = 7 3 4" Refractor Globe, Type V R1C = R1 with Cast Guard R3C = R3 with Cast Guard R5C = R5 with Cast Guard R1P = R1 with Polymeric Guard R3P = R3 with Polymeric Guard R5P = R5 with Polymeric Guard TG = 7 3 4" Thermal Shock-Resistant Globe TGC = TG with Cast Guard TGP = TG with Polymeric Guard Refractor Glass are available for all wattages RR2 = 12 Glass Refractor Type II RR2G = 12 Glass Refractor Type II with Wire Guard RR5 = 12 Glass Refractor Type V RR5G = RR5 with Wire Guard 8 Mounting Style A2 = 3 4" Cone-Top Pendant A3 = 1" Cone-Top Pendant B2 = 3 4" Wall Mount B3 = 1" Wall Mount C2 = 3 4" Ceiling Mount C3 = 1" Ceiling Mount F2 = 3 4" Flexible Pendant F3 = 1" Flexible Pendant HV1 = HazVertor Ring Class I, Div. 2 HV2 = HazVertor Ring Class II, Div. 1 L4 = 1 1 4" Straight Stanchion L5 = 1 1 2" Straight Stanchion P2 = 3 4" Rigid Pendant P3 = 1" Rigid Pendant S4 = 1 1 4" 25 Angle Stanchion S5 = 1 1 2" 25 Angle Stanchion 9 Special Options T =HazCote Custom Corrosion Coating (Consult Factory) 10 UNIPAK * E = UNIPAK with Induction Lamp 11 Fusing Options F = Fuse Block(s) with Fuse(s) 12 Certification C = Canadian Market (CSA Label) (*) Available Unipak only Class I Zone 2, Groups IIC, IIB, IIA Division 2, Groups A, B, C and D Class II Divisions 1 and 2, Groups E, F and G Class III UL Listed (UL1598A) for Marine Locations UL844 NEMA 4X, IP66 CSA C22.2 No 137 standard Contact your Thomas & Betts sales representative to verify classification. * Reflectors are shipped uninstalled and separately.

10 Hazlux 3 Induction Low Wattage Area Lighting Hazlux 3 Class I, Division 2 Mounting Options Rigid Pendant Cone-Top Pendant Flexible Pendant Ceiling Mount HazVertor Adapter Ring Wall Mount 25 Angle Stanchion Straight Stanchion Wall Mount for High Vibration Applications 25 Angle Stanchion for High Vibration Applications Straight Stanchion for High Vibration Applications CAT. NO. DESCRIPTION CONDUIT HUB SIZE VP2 Rigid Pendant 3 4" VP3 1" VA2 Cone-Top Pendant 3 4" VA3 1" VF2 Flexible Pendant 3 4" VF3 1" VC2 Ceiling Mount 3 4" VC3 1" VB2 Wall Mount 3 4" VB3 1" VB2-VIB Wall Mount for High 3 4" VB3-VIB Vibration Applications 1" VS4 25 Angle Stanchion 1 1 4" VS5 1 1 2" VS4-VIB 25 Angle Stanchion for High 1 1 4" VS5-VIB Vibration Applications 1 1 2" VL4 Straight Stanchion 1 1 4" VL5 1 1 2" VL4-VIB Straight Stanchion for High 1 1 4" VL5-VIB Vibration Applications 1 1 2" HV1 HazVertor Adapter Ring N/A Globes or Refractors CAT. NO. DESCRIPTION VGT31S 7 3 4" dia. Heat-Resistant Globe (250W max.) VGL31R1 7 3 4" dia. IES Type I Refractor Globe (250W max.) VGL31R3 7 3 4" dia. IES Type III Refractor Globe (250W max.) VGL31R5 7 3 4" dia. IES Type V Refractor Globe (250W max.) VRF31C2 12" dia. IES Type II Refractor Glass, 7 3 4" Thread VRF31C5 12" dia. IES Type V Refractor Glass, 7 3 4" Thread Heat-Resistant Globe Type I, III or V Refractor Globe Type II or V Refractor Glass * Tuff-Skin coating is available - contact technical support for additional information. Tuff-Skin is a registered trademark of Thomas Manufacturing Corp. Reflectors CAT. NO. DESCRIPTION Standard Dome VR31P VRD31 VRA31P Standard Dome, Fiberglass-Reinforced Polyester Deep Dome, Anodized Aluminum 30 Angle Reflector, Fiberglass-Reinforced Polyester 30 Angle Reflector Deep Dome Guards CAT. NO. VGU31RP VGU31R VGR48 DESCRIPTION Polymeric Guard for VGT31S Globe and VGL31R Series Refractor Globes Cast Aluminum Guard for VGT31S Globe and VGL31R Series Refractor Globes Steel Wire Guard for All VRF Series 12" Refractors Polymeric Guard Cast Guard VGR48 Wire Guard

Hazlux 3 Induction Low Wattage 11 Dimensions R-Housing with Globe and Guard Photometry R-Housing with Refractor 13 3 8" (340mm) 14 1 2" (368mm) 14 7 8" (377mm) 16 5 8" (422mm) Ceiling Mount Reference Data Catalog No. DI005EUNRTGA2-E Lamp 55W Induction lamp Lamp Lumens N.A. (absolute) Input Watt 55.71 Luminaire Lumens 3644 Candlepower Curve 417 313 209 104 Ceiling Mount Wall Mount Efficiency NA Efficacy Rating (LER) 65 Spacing Criterion (0-180) 1.38 Spacing Criterion (90-270) 1.38 Spacing Criterion (diagonal) 1.58 R-Housing with Refractor and Guard 13 3 8" (340mm) Ceiling Mount 14 1 2" (368mm) 14 7 8" (378mm) Wall Mount 16 5 8" (422mm) Ceiling Mount Reference Data Catalog No. DI005EUNRR5A2-E Lamp 55W Induction lamp Lamp Lumens N.A. (absolute) Input Watt 55.87 Luminaire Lumens 3351 Efficiency NA Efficacy Rating (LER) 60 Spacing Criterion (0-180) 1.90 Spacing Criterion (90-270) 1.90 Spacing Criterion (diagonal) 2.22 Candlepower Curve 460 345 230 115 R-Housing with 12 Refractor Glass 13 3 8" (340mm) 17 5 16" (440mm) 14 7 8" (378mm) 19 9 16" (497mm) Ceiling Mount Reference Data Catalog No. DI010EUNRRR5A2-E Lamp 100W Induction lamp Lamp Lumens N.A. (absolute) Input Watt 100.5 Luminaire Lumens 5245 Candlepower Curve 720 540 360 180 Efficiency NA Ceiling Mount Wall Mount Efficacy Rating (LER) 61 Spacing Criterion (0-180) 1.36 Spacing Criterion (90-270) 1.36 Spacing Criterion (diagonal) 1.70

12 Hazlux 3 Induction High Wattage Now You Can Use the Longest-Life Lamp Available on the Market. In industrial plants, reliable lighting is often required in hazardous, hard-to-reach places. Lamp replace ment not only places employees at risk, but often requires the rental of expensive equipment such as scissor lifts. I sure don t envy the person who has to change these lamps! With the introduction of Hazlux Induction Lighting Luminaires for hazardous areas (Class 1, Div. 2 Groups A, B, C, D) and non-hazardous areas, you can benefit from one of the longest lamp lives available on the market. Features include: 65,000+ hour lamp life Reduced maintenance/re-lamp operations Instant On/Instant Restrike Automatic switch-off in case of failure 5000K CCT Standard Exceptional energy efficiency -40 C to 40 C ambient operating range Retrofits into existing Hazlux 3 applications RFI-approved (FCC part 18 reference luminaire) Here s how you save maintenance costs with Hazlux Induction Lighting: Eliminates the need for expensive HID options such as Quartz Auxiliary Lamps or Instant Restrike Reduces risks to installers performing maintenance in hard-to-reach places Increases efficiency by decreasing machine shutdown time Reduces number of times necessary to de-energize entire circuit of lights for maintenance in hazardous locations Lowers cost of expensive rental of scissor lifts or bucket trucks Hazlux 3 Induction Certification Guide WATTS AMBIENT TEMP ( C) CLASS I, DIVISION 2 GROUPS A, B, C, D TEMPERATURE CODE CLASS II, DIVISION 1 UL 1598A MARINE NEMA 4X* SUPPLY WIRE TEMP. RATING ( C) 165 40 T2A T6 Yes Yes 90 Hazlux Induction Lighting reduces the cost of expensive maintenance of industrial lighting in hazardous locations. Note: 1. Simultaneous presence applications: Some Hazlux 3 luminaires are UL Listed for simultaneous presence of gas and dust. Contact Hazlux for specific information. 2. Tuff-Skin Coated Optics: Many Hazlux 3 luminaires are UL Listed with Tuff-Skin (silicone) coating on glass optics. Contact Hazlux for specific information. 3. For UL and CSA Certification Information on other ambient temperatures and luminaire configurations, consult the factory. 4. Tuff-Skin is a registered trademark of Thomas Manufacturing Corp.

Hazlux 3 Induction High Wattage 13 Area Lighting Hazlux 3 Class I, Division 2 Luminaire Assembly Guide Mounting Style HazVertor Adapter Ring Rigid or Flexible Pendant Cone-Top Pendant Ceiling Mount Wall Mount 25 Angle Stanchion Straight Stanchion Ballast Tank L-Tank Refractor Refractor Globe Guard Steel Wire Guard

14 Hazlux 3 Induction High Wattage Area Lighting Hazlux 3 Class I, Division 2 Catalog Numbering System D I Ø 16 E 12 L - R5G - P2 T E F 1 2 3 4 5 6 7 8 9 10 11 12 13 C 1 Hazlux 3 HID Luminaire D = Class I, Div. 2, Groups A, B, C and D D = Class I, Zone 2, Groups IIA, IIB, IIC D = Class II, Div. 1 & 2, Groups E, F and G D = Class III UL 595 Marine Locations, Wet Locations, NEMA 4X 2 Lamp Type I = Induction Lighting 3 Starter Circuit/Quartz Options Ø = Standard Luminaire 4 Lamp Wattage 16 = 165 Watt Induction System 5 Ballast Circuit E = Electronic Ballast (Induction Luminaire) 6 Voltage 12 = 120V, 60 Hz 06 = 208/240/277V 50 or 60 Hz 34 = 347V 60 Hz (CSA) 7 Ballast Housing Style L = Large Housing M = Large Housing with Stainless Steel Inserts 8 Refractor R5G = Type V Refractor with Wire Guard R5 = Type V Refractor 9 Mounting Style A2 = 3 4" Cone-Top Pendant A3 = 1" Cone-Top Pendant Mount B2 = 3 4" Wall Mount B3 = 1" Wall Mount C2 = 3 4" Ceiling Mount C3 = 1" Ceiling Mount F2 = 3 4" Flexible Pendant F3 = 1" Flexible Pendant HV1 = HazVertor Ring Class I, Division 2 HV2 = HazVertor Ring Class II, Division 1 L4 = 1 1 4" Straight Stanchion L5 = 1 1 2" Straight Stanchion P2 = 3 4" Rigid Pendant P3 = 1" Rigid Pendant S4 = 1 1 4" 25 Angle Stanchion S5 = 1 1 2" 25 Angle Stanchion 10 Coating T =HazCote Custom Corrosion Coating 11 UNIPAK * E = UNIPAK with Induction Lamp 12 Fusing Options F = Fuse Block(s) with Fuse(s) 13 Certification C = Canadian Market (CSA Label) (*) Available Unipak only Class I Zone 2, Groups IIC, IIB, IIA Division 2, Groups A, B, C and D Class II Divisions 1 and 2, Groups E, F and G Class III UL Listed (UL1598A) for Marine Locations UL844 NEMA 4X, IP66 CSA C22.2 No 137 standard Contact your Thomas & Betts sales representative to verify classification.

Hazlux 3 Induction High Wattage 15 Area Lighting Hazlux 3 Class I, Division 2 Mounting Options Rigid Pendant Cone-Top Pendant Flexible Pendant Ceiling Mount HazVertor Adapter Ring Wall Mount 25 Angle Stanchion Straight Stanchion Wall Mount for High Vibration Applications 25 Angle Stanchion for High Vibration Applications Straight Stanchion for High Vibration Applications CAT. NO. DESCRIPTION CONDUIT HUB SIZE VP2 Rigid Pendant 3 4" VP3 1" VA2 Cone-Top Pendant 3 4" VA3 1" VF2 Flexible Pendant 3 4" VF3 1" VC2 Ceiling Mount 3 4" VC3 1" VB2 Wall Mount 3 4" VB3 1" VB2-VIB Wall Mount for High 3 4" VB3-VIB Vibration Applications 1" VS4 25 Angle Stanchion 1 1 4" VS5 1 1 2" VS4-VIB 25 Angle Stanchion for High 1 1 4" VS5-VIB Vibration Applications 1 1 2" VL4 Straight Stanchion 1 1 4" VL5 1 1 2" VL4-VIB Straight Stanchion for High 1 1 4" VL5-VIB Vibration Applications 1 1 2" HV1 HazVertor Adapter Ring N/A Globes or Refractors CAT. NO. DESCRIPTION VRF31C5 12" dia. IES Type V Refractor Glass, 7 3 4" Thread Type V Refractor * Tuff-Skin coating is available - contact technical support for additional information. Tuff-Skin is a registered trademark of Thomas Manufacturing Corp. Guards CAT. NO. VGR48 DESCRIPTION Steel Wire Guard for All VRF Series 12" Refractors Wire Guard

16 Hazlux 3 Induction High Wattage Dimensions Large Housing with 12 Refractor Photometry Large Housing with 12 Refractor 13 3 8" (340mm) 13 3 8" (340mm) Ceiling Mount Reference Data Catalog No. DI016E12L-R5-P2E Candlepower Curve 2099 20 7 8" (530mm) 25 3 8" (644mm) Lamp 165W Induction lamp Lamp Lumens 12000 Input Watt 165 Luminaire Lumens 6890 1574 1050 525 Efficiency 57% Flexible Pendant Cone-Top Pendant Efficacy Rating (LER) 42 Spacing Criterion (0-180) 1.12 13 3 8" (340mm) 14 7 8" (378mm) Spacing Criterion (90-270) 1.12 Spacing Criterion (diagonal) 1.30 21 1 2" (546mm) 23 3 4" (603mm) Ceiling Mount Wall Mount 16 1 8" (410mm) 15 3 4" (400mm) 22 3 8" (568mm) 22 3 8" (568mm) 25 Angle Stanchion Mount Straight Stanchion 13 3 8" (340mm) 21 3 4" (552mm) HazVertor Ring

Hazlux 5 Induction 17 Hazardous Area Lighting Hazlux 5 Induction Lighting Luminaires for Class I, Division 1, Groups C and D Hazardous Locations Features UL Listed for Class I, Division 1 for safe, explosion-proof application in a variety of hazardous areas Temperature Range: -40 C to 40 C (temperatures down to -50 C available with our Cold Weather Circuit option) Factory-sealed assembly meets code requirements without the need for external sealing fittings Dual-pitch Acme threads make assembly easy and faster than designs with standard V-cut threads, greatly reducing the risk of cross threading Factory-wired connection block means ballast is pre-wired to lower half of electrical connection block, allowing wireless connection of ballast housing to mounting module Five mounting styles pendant, ceiling, wall, angle stanchion and bulkhead provide versatility for installation Thermal shock-resistant glass globes are factory assembled and pre-tested to ensure the highest quality and safety Die-cast aluminum guards are epoxy powder coated for corrosion resistance and have keyhole slots for easy attachment to stainless steel screws Polymeric reflectors are available in standard dome and 30 angle versions Thomas & Betts realizes that when your design calls for explosion-proof Class I, Div. 1 lighting luminaires, workers and equipment will be in extreme environments. Even the most basic maintenance requires work areas to be evacuated of all dangerous gases, vapors, and residuals before the work can start. In addition, there can be significant costs associated with maintenance in these classified areas, not to mention the interruption and subsequent start-up costs. Also, safety for facility personnel and risk of equipment damages is elevated with constant maintenance in this type of environment. In an effort to reduce downtime and increase safety in highly explosive environments, Thomas & Betts is introducing an explosion-proof induction luminaire with one of the longest life-spans in the market (100,000 Hours). Demand Thomas & Betts Induction Hazlux luminaires for your next project. Applications Chemical Plants Oil Refineries Offshore Platforms Waste Treatment Facilities Automotive Manufacturing Plants Paint Manufacturing Facilities Paint Spray Locations Chemical and Plastic Mixing and Storage Areas Pipeline Pumping Stations Oil and Gas Terminals Defense and Government Facilities Wattages Induction: Materials and Finishes Ballast Housing: Mounting Modules: Hardware: 35, 55, 85 W Copper-free aluminum, powder finish Copper-free aluminum, powder finish Stainless steel Hazlux 5 Induction Certification Guide CLASS I, GROUPS C & D (USED WITH) GLOBE WITH OR WITHOUT EXTERNAL REFLECTOR CLASS II, GROUPS E, F & G (USED WITH) GLOBE WITH OR WITHOUT EXTERNAL REFLECTOR SUPPLY WIRE TEMP. RATING ( C) WATTS AMBIENT TEMP ( C) UL 1598A MARINE NEMA 3R 35 40 85 C (T6) T6 No Yes 90 55 40 85 C (T6) T6 No Yes 90 100 40 85 C (T6) T6 No Yes 90 Globes: Guard: Reflectors: Tempered glass Copper-free aluminum, powder finish Fiberglass-reinforced

18 Hazlux 5 Induction Hazardous Area Lighting Class I, Division 1 Luminaire Assembly Guide Mounting Style Pendant Mount Stanchion Mount Ceiling Mount Wall Mount Bulkhead Mount Luminaire and Globe Guard Cast Guard Reflectors* Standard Dome 30 Angle Reflector * Reflectors are shipped uninstalled and separately.

Hazlux 5 Induction 19 Hazardous Area Lighting Class I, Division 1 Catalog Numbering System XI Ø 03 E UN G B2 T E C 1 2 3 4 5 6 7 8 9 10 1 Luminaire Series XI = Hazlux 5 Induction Series 2 Starter Circuit Ø = Standard Luminaire (Without Options) C = Cold Weather Circuit (-50 C) 3 Lamp Wattage 03 = 35 Watts 05 = 55 Watts 08 = 85 Watts 4 Ballast Circuit E = Electronic Ballast 5 Voltages/Frequency UN = 120 to 277 Vac, 50/60 Hz 34 = 347 Vac, 60 Hz 48 = 480 Vac, 60 Hz 6 Guard Blank = No Guard G = Cast Guard 7 Mounting Style B2 = 3 4" Wall Mount B3 = 1" Wall Mount C2 = 3 4 Ceiling Mount C3 = 1 Ceiling Mount J2 = 3 4" Bulkhead J3 = 1" Bulkhead P2 = 3 4" Rigid Pendant P3 = 1" Rigid Pendant S4 = 1 1 4" 25 Angle Stanchion S5 = 1 1 2" 25 Angle Stanchion 8 Special Options T = HazCote Custom Corrosion Coating on all Aluminum Parts PS = UL Luminaire l for Paint Spray Areas PST = UL Listed Luminaire for Paint Spray Areas with HazCote 9 UNIPAK Options E = UNIPAK with Induction Lamp 10 Certification C = Canadian Market (CSA Label) Class I Division 1, Groups C and D Zone 2, Groups IIC, IIB and IIA Division 2, Groups A, B, C and D Class II Divisions 1 and 2, Groups E, F & G UL Listed UL844 NEMA 3R CSA C22.2 No 137 standard Contact your Thomas & Betts sales representative to verify classification. * Reflectors are shipped uninstalled and separately.

20 Hazlux 5 Induction Mounting Options Pendant Mount Stanchion Mount Ceiling Mount Wall Mount Bulkhead Mount CAT. NO. DESCRIPTION CONDUIT HUB SIZE STD. PKG. XP2 Pendant Mount 3 4 1 XP3 1 XS4 Stanchion Mount 1 1 4 1 XS5 1 1 2 XC2 Ceiling Mount 3 4 1 XC3 1 XB2 Wall Mount 3 4 1 XB3 1 XJ2 Bulkhead Mount 3 4 1 XJ3 1 Outlet Boxes include female electrical connectors and appropriate close-up plugs. Guards CAT. NO. XGU44 DESCRIPTION Cast Aluminum Guard XGU44 Cast Aluminum Guard Replacement Globe Assemblies CAT. NO. XGSA44 DESCRIPTION Hazlux 5 Replacement Globe Assembly Reflectors Standard Dome CAT. NO. VR31P VRA31P DESCRIPTION Standard Dome, Fiberglass-Reinforced Polyester 30 Angle Reflector, Fiberglass-Reinforced Polyester 30 Angle Reflector Note: Reflectors are shipped uninstalled and separately.

Hazlux 5 Induction 21 Dimensions Wall Mount with Globe and Guard 10 3 4" (273mm) 16 19 32" (421mm) 11 11 16" (297mm) 5 9 16" (141mm) 8 5 8" (219mm) 8 15 16" (227mm) Photometry Ceiling Mount Reference Data Catalog No. XI008EUNGC2E Lamp 85W Induction lamp Lamp Lumens N.A. (absolute) Input Watt 91.49 Luminaire Lumens 3578 Efficiency N.A. Efficacy Rating (LER) 39 Spacing Criterion (0-180) 1.52 Spacing Criterion (90-270) 0.60 Spacing Criterion (diagonal) 1.84 Candlepower Curve 472 354 236 118 Stanchion Mount with Globe, Guard and Reflector 26 29 32" (683mm) 18 3 32" (460mm) 13 3 4" (349mm) 5" (127mm) 10 1 2" (267mm) 9 1 2" (241mm) 20 19 32" (523mm) 11 11 16" (297mm) 18 1 8" (460mm) 8 5 8" (219mm) 8 5 8" (219mm) 8 15 16" (227mm) Ceiling Mount Reference Data Catalog No. Lamp Lamp Lumens Input Watt 91.51 Luminaire Lumens 2989 Efficiency XI008EUNGC2E (VR31P) 85W Induction lamp N.A. (absolute) N.A. Efficacy Rating (LER) 33 Spacing Criterion (0-180) 1.38 Spacing Criterion (90-270) 1.38 Spacing Criterion (diagonal) 1.58 Candlepower Curve 472 354 236 118 20 1 8" (511mm) Bulkhead Mount with Globe, Guard and Reflector Ceiling Mount with Globe and Guard 11 3 8" (289mm) 14 3 16" (360mm) 11 11 16" (297mm) 2 9 16" (65mm) 8 5 8" (219mm) 11 11 16" (297mm) 8 15 16" (227mm) 18 1 2" (470mm) 26 7 16" (672mm) 8 5 8" (219mm) 8 15 16" (227mm) 20 1 8" (511mm) 5" (127mm) 13 3 4" (349mm) 20 1 8" (511mm)

22 Hazlux Quick Pole Assembly Features & Benefits If you need to maintain or service Hazlux hazardous lighting luminaires in hard-to-reach locations, in which a ladder is not recommended or against code, the Thomas & Betts Quick Pole assembly can make the operation quicker, safer, and more efficient. The quick pole allows users to lower the luminaire to a safe working height, reducing this operation to a one-man task without the need of ladders, lifts, or harnesses. Once the luminaire is serviced, it can be returned to its original position and locked with a safety pull-pin. If safety, efficiency and cost are your primary concerns, the Quick Pole is a great companion to your Hazlux lighting luminaire installation. Construction Sphere shaped, quick knuckle features round edges, preventing injuries and contaminent build-up of components The quick release mechanism is activated using one hand and one pull pin The quick pole assembly blocks at a 90º angle when the pull pin reaches the stopper All quick knuckle hardware is made of stainless steel All mounting bracket hardware is hot dip galvanized Quick Pole Assembly Operates in any kind of weather Overall length is 10' (3 m) Pole trade size is 1-1/2" treaded NPT. Aluminum pole trade size is 2" treaded NPT Top pole section is 70" (1.78 m) long Lower pole section is 50" (1.27 m) long Set screws secure top and bottom section into the quick knuckle Quick Knuckle Assembly Rotates 180º (90º left and right) around the knuckle s center axis allowing freedom of installation and easy adjustment Easy one man operation. After center bolt is loosened, use the pull pin to lock and unlock the assembly Pre-fished with tape to ease wiring Brackets Universal mounting for 2 to 3 angle iron railings Quick mounting brackets can be installed inside or outside the guardrails Quick knuckle assembly should be mounted above the hand rail allowing the pole sections to rotate before final positioning

Hazlux Quick Pole Assembly 23 Galvanized Standard Kit Retrofit Kit Overall height of 10' (3 m) 1-1/2 NPT treads at both ends Installed with two rail mounting brackets 1. Rotating Quick Knuckle Assembly 2. Angle Iron Mounting Brackets allowing the pole section to rotate before final positioning 1 Overall maximum and predetermined height of 10' (3 m) once assembled Can be adapted to existing pole Upgrades existing assembly with quick and easy maintenance features See instruction sheets provided with product for installation details 1 1. Rotating Quick Knuckle Assembly 2. Tapered Adaptor, fits over Standard 1-1/4" or 1-1/2" NPT Pipe 2 2 Cat. No.: Q-P-5-10-N Q-P-A-5-10-N (Aluminum) Cat. No.: RQ-P-5-10-N RQ-P-A-5-10-N (Aluminum) SAFETY FIRST One person operation No ladders or lifts required Simplified maintenance Hot dipped galvanized steel and aluminum finishes Frees up catwalks and walkways during maintenance Epoxy coated finishes available Suitable for 180km/h winds* as per AASHTO LTS-4 2001 Steel pole treads are treated and protected to prevent galvanic reaction as per AASHTO LTS-4 2001 CSA certified products Universal Bracket Kit Cat. No.: AMB-QP-BKT-N AMB-QP-A-BKT-N (Aluminum) Cat. No.: RMB-QP-BKT-N RMB-QP-A-BKT-N (Aluminum) Quick bolt-on installation, no welding or drilling Can be attached to angle iron guardrails up to 3" Can be installed on tubular structures less than 2" O.D. Allows the pole sections to rotate before final positionning

Visit our world of electrical product solutions Visit the Electrical World section of our web site at www.tnb.com for more information on Thomas & Betts solutions including our newest products, plus user-friendly catalog and competitive part number search, application and technical support and other useful information. Click on the Electrical World icon or go to: tnbelectricalworld.tnb.com. Industry codes and specifications Thomas & Betts products meet or exceed applicable industry specifications or codes which are detailed in the appropriate T&B product literature. United States Thomas & Betts Corporation Electrical Division Headquarters 8155 T&B Boulevard Memphis, TN 38125 Phone: 901.252.8000 Fax: 800.816.7810 Technical Services: 888.862.3289 Email: techsupport@tnb.com Canada Thomas & Betts Ltd 700 Thomas Avenue Saint-Jean-sur-Richelieu, Quebec J2X 2M9 Phone: 450.347.5318 Fax: 450.347.1976 Latin America Mexico: 01-800-TNB-HELP Central America & Caribbean: +52.81.8329.7707 South America: +52.81.8329.7743 Email: servicioalcliente@tnb.com Europe/Africa T&B European Centre 200 Chaussée de Waterloo B-1640 Rhode-St-Genèse Belgium Phone: +32.235.98200 Email: europe_inquiry@tnb.com Middle East Thomas & Betts Ltd PO Box 54567 Dubai Airport Free Zone Bldg. 6WA Suite 724 Dubai United Arab Emirates Phone: +9714 6091635 Fax: +9714 6091636 Asia Pacific Thomas & Betts Asia Pte Ltd 10 Ang Mo Kio Street 65 #06-07 Techpoint Singapore 569059 Phone: +65.6720.8828 Fax: +65.6720.8780 Email: asia_inquiry@tnb.com Online CAD library Thomas & Betts offers free download of two- and three-dimensional CAD models of many of its products in more than 90 native CAD formats at: www.tnb.com/cadlibrary Please ask your Thomas & Betts sales representative for a complete catalog of quality Thomas & Betts electrical products or visit us at www.tnb.com. For customer service, call 1-800-816-7809. For technical questions, call 1-888-862-3289. 2013 Thomas & Betts Corporation. All rights reserved. Printed in the U.S.A. 09/13/XM GM7122 Thomas & Betts Corporation Electrical Division 8155 T&B Boulevard Memphis, TN 38125 901-252-5000 www.tnb.com