MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

Similar documents
Energy-Saving Industrial Water Chillers

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

Call us today! (800)

Call us today! (800)

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

Call us today! (800)

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Air-Cooled Condensing Units with Compact Screw Compressors

MAC-120HE-03 Air-Cooled Chiller

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

MEDICAL CHILLER SYSTEMS

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

C13-Series Engineering Guide

NQ Series Portable Chillers

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

.2 Section Waste Management and Disposal.

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Central Chillers TS Series

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

Product Chillers A P P L I C AT I O N S

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Air-Cooled Global Chiller

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

30GN FLOTRONIC II AIR-COOLED CHILLERS

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

PACKAGED AIR COOLED Product Data Catalog

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

30GT FLOTRONIC AIR-COOLED CHILLERS

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Delta T Systems Variable Speed Chillers Technical Specifications for 1-30 Air Cooled and 2-30 Water Cooled Chillers

Precise Temperature Control; Compact Footprint

VariCool VAV Engineering Guide

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

General Description. Operation

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

DTW Works Master Specification Version 2006 Issued 2006/08/01 Section15621 Packaged Reciprocating Water Chillers Page 1 of 5

Modular Air Cooled Scroll Chillers

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

ENGINEERING MANUAL 3, 5, & 7 TONS PRECISION ENVIRONMENTAL CONTROL

Temptek Auxiliary Equipment

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

VertiCool Aurora Engineering Guide

Liebert CSU3000 Chiller

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

MODELS LIST. Nominal Capacity RT

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

PAR5. Product Specifications

GP SERIES Packaged Chillers

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

SpaceKeeper Console (SKC)

HYDROCIAT LW R407C. Water cooled chillers USE RANGE

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

Data Aire LCS TM (Large Ceiling System) R-407C. 6, 8, 10, and 13 ton. ISO 9001 Certified

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

EHH SERIES DRAW THROUGH FAN COILS CFM

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

Product Data. Features/Benefits. 07DA, DB 07EA, EB, ED Condensing Units. 06D, 06E Compressors. 3 to 40 Nominal Tons

NEW INTELLIGENT AIR TECHNOLOGY

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

Air-Cooled Condensers

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

Advance Release September 2009

Aquaflair TRAC-TRAF-TRAH

Air-Cooled Stand-Alone ASC Chillers 20 thru 195 Tons

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

Modular Data Temp Systems Air Cooled Water/Glycol Cooled R-407C. 8, 10 and 13 ton capacities. ISO 9001 Certified

SECTION ROTARY SCREW WATER CHILLERS Vibration Isolation Pumping Equipment (HVAC) Induced Draft Cooling Tower

Modular Data Temp Systems Air Cooled Water/Glycol Cooled 8, 10 and 13 ton capacities R-410A. ISO 9001 Certified

CASE STUDY AIR-CONDITIONERS

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

Levitor II. AIR-COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS (Available for Fluid Cooler Applications)

TECAM S.A. harmony. 5PZA Direct Expansion. Air Conditioning Equipment Manufacturer. R-410A PRECISION UNIT 2 Ton 6 Ton / 60 Hz. Tecnología Ambiental

DSH Model Air Cooled Self Contained Indoor Packaged Units 2-5 Tons Preliminary Application Data

TRIDENT GS SERIES Central Chiller

REFRIGERATION PRODUCTS

Outstanding Performance; Application Flexibility

ULTIMATE ENERGY SAVING TECHNOLOGY

Refrigerated Compressed Air Dryers

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

LARGE CAPACITY, REFRIGERATED COMPRESSED AIR DRYERS WITH TRUE-CYCLING TM OPERATION AND REDUNDANT OPERATING SYSTEMS. MultiPlex.

The six in-house brands are Classic, Cooline, CoolCare, Clima Tech, Geoclima and Kessler Clima Tech.

LC Series Chillers. Engineering Catalog. Air-Cooled Condenser

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

R22 R407C. 60Hz. ACHDX Series. 225 to 415 Tons. Air Cooled Horizontal Rotary Screw Chillers. Products That Perform...

Transcription:

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers 60-500 Tons n Mission Critical Cooling n Central Plant Process Cooling n Specialized HVAC Cooling Systems COOLING SOLUTIONS www.motivaircorp.com

MLC & MLC-FC RANGE OF CHILLERS RELIABILITY The MLC chillers have been designed for ultimate reliability. Dual screw compressors, independent refrigeration circuits, automatic lead/lag control, state of the art PLC controllers with multiple safeties and alarms, and premium refrigeration components all combine to create a reliable chiller suited for the most demanding applications. EFFICIENCY & FLEXIBILITY This new generation of MLC & MLC-FC chillers utilizes the latest technologies to produce the highest possible efficiency. By integrating PLC algorithms, variable frequency drives, R-134a refrigerant and cutting edge production techniques, Motivair is able to maximize chiller performance with minimum energy consumption. Unlike many other manufacturers, Motivair has the ability to modify and adapt its standard range of chillers to meet a customer s unique needs. Chillers can be designed for high or low water and high or low ambient temperatures. Chillers can be equipped with an Integrated Free Cooling system, low noise option, high elevation package, pump and tank stations. They can be adapted to integrate with almost any Building Control System. These options along with many other custom additions allow Motivair to create the best solution for any customer s cooling requirements. CONTROL Optimizing the performance of the MLC chillers is achieved through a customized PLC controller. Close control of the supply water temperature and total control of the chiller operation allows the customer to receive the very best performance from the chiller and the equipment being cooled. Eight total steps of unloading achieve optimal stability during changing heat loads, while minimizing power costs. Compressor lead/lag control can be customized by the operator, and insures even wear on each refrigeration screw compressor. Condenser fan speed control insures reliable operation during exposure to low ambient temperatures. An optional Integrated Free-Cooling System built into the chiller automatically switches the chiller operation to maximize energy savings and increase chiller component life when ambient temperatures drop below the selected return water temperatures.

MLC & MLC-FC CHILLER FEATURES REFRIGERATION COMPRESSORS All MLC chillers feature two heavy duty, 3500-RPM semi hermetic screw compressors mounted in two completely independent refrigeration circuits. Each compressor features 4 steps of unloading for virtually unlimited capacity control. One circuit can be serviced while the second circuit remains fully operational. Positive lubrication, low oil level switch, motor over temperature protection and Liquid injection, all combine to provide extended compressor life. EVAPORATOR The MLC & MLC-FC chillers feature an ASME U stamped, dual circuited evaporator mounted on the chiller base. Carbon steel shell with heavy gauge copper tubes insures long life and highly efficient heat transfer under varying loads. All MLC evaporators feature removable end bonnets and pressure relief valves. REFRIGERANT COMPONENTS Each circuit includes an electronic expansion valve, liquid receiver, filter dryer with replaceable core, sight glass with color-change moisture indicator, pump down service valves on compressor and receiver, high and low side service access valves, HP and LP pressure safety switches, and glycerin filled HP and LP gauges. CONDENSERS The MLC air-cooled condensers are constructed from seamless copper tubes expanded into aluminum fins. The large face area, combined with the induced air flow from multiple fans results in 100% rated cooling capacity at 95 F ambient. Standard fan speed control permits reliable chiller operation in -20 F (glycol required). Remote air-cooled condensers feature galvanized steel or aluminum housings, compartmentalized fans, weatherproof fan motors, fan cycling/fan speed control, and independent fan motor overloads and contactors. CONDENSER FANS & MOTORS Fans feature heavy-duty, cast aluminum blades, which do not flex or lose efficiency at the top of their performance CONDENSER curve. Motors FAN/MOTOR are TEAO; suitable for outdoor use, and variable speed operation. These exceptionally reliable motors feature reversed stator and rotor, which eliminates the traditional motor shaft. The outer shell of the motor is the rotating body, to which the rigid cast aluminum blades are cast or bolted. This unique arrangement reduces torque stress on the blades, eliminates fan blade stress fractures, maximizes airflow, and maintains efficiency over the entire performance curve. REFRIGERANTS As a global supplier Motivair produces the MLC & MLC-FC chillers with the widest variety of environmentally compatible refrigerants available in industry today. The current standard is R-134A refrigerant which is the most efficient refrigerant available. Other options include R-407C and R-404A which are used based on application requirements. MLC-RC 510

MLC-FC INTEGRATED FREE-COOLING THE ULTIMATE SOLUTION FOR OPTIMAL ENERGY SAVINGS The Motivair MLC-FC chillers with Free-Cooling capability are designed to provide the owner with optimal performance, year round, in varying ambient temperatures. This Free-Cooling option, available on models MLC-FC 200 MLC-FC 1750 is supplied complete with Free-Cooling coil and the PCO3 advanced PLC control package a unique single package for year-round energy savings. The refrigeration plant is designed to cool the designated heat load during the highest summer temperatures. When ambient temperatures fall overnight or during cooler seasonal weather, the integrated Free-Cooling system is automatically activated. The system operates by directing the return chilled glycol through the Free-Cooling coil, before it enters the evaporator. This is achieved via an automatic motorized valve, controlled by the PLC, whenever the ambient falls below the return chilled glycol temperature set point. The glycol is either partially or completely cooled in the Free- Cooling coil for maximum energy savings. As a result, less mechanical refrigeration is required to achieve the chilled glycol set point, and the refrigeration compressors are cycled off by the PLC, which continuously monitors the system. Energy savings in areas with cooler winter months are substantial. Wear and tear on chiller components is dramatically reduced, due to fewer running hours during winter months. Automatic switching between mechanical cooling and Free-Cooling allows for optimal performance year round. As a general rule of thumb, Free-Cooling savings more than pay for the initial investment in the first year of operation! The MLC-FC range has been designed, built and tested specifically as packaged Free Cooling Chillers. There are no aftermarket or 3rd party add-on free cooling coils, components or controls. Motivair free cooling chillers are ETL tested and listed. Motivair is the only manufacturer with a cataloged and tested Free Cooling chiller range. Trust your mission critical process to the Free Cooling Chiller experts by specifying Motivair Free Cooling chillers. PLC CONTROLLER COMPRESSOR 21.6 3-WAY VALVE FANS GLYCOL IN CONDENSER / FREE COOLING COIL TEMP SENSOR EVAPORATOR EXP VALVE TEMP SENSOR PUMP STORAGE TANK TEMP SENSOR GLYCOL OUT

ADIABATIC EFFICIENCY BOOSTING SYSTEM AIR-COOLED CHILLER SYSTEMS The Motivair Adiabatic Efficiency Boosting System uses a proprietary evaporative Pre-Cooling media designed to pre-cool warm ambient air before it reaches the air-cooled chiller condenser coils. During warmer seasonal weather, the Adiabatic System automatically activates and allows a small flow of city water to wet the evaporative media. Warm, dry air first passes through the evaporative media where it is pre-cooled before it enters the condenser coils. Water that is not evaporated is collected and recycled. Depending on geographic location, inlet air temperatures can be reduced by up to 20 o F yielding significant chiller efficiency gains, increased reliability during extreme summer weather and reduced building energy demand loads. The evaporative media is specifically designed for ultra low pressure drop with virtually no added static to condenser fans. As a factory supplied option, media thickness and air flow velocities are designed to allow zero water carry over onto the chiller coils. The evaporative media is easily removed for field service, cleaning or inexpensive replacement. Virtually maintenance-free and requiring little or no water treatment the Adiabatic System is ideal for clients seeking simple and reliable efficiency gains for their air-cooled chiller system. FREE-COOLING CHILLER SYSTEMS Motivair Free Cooling chillers can be ordered with the adiabatic option fitted. By automatically turning on the system when Free Cooling is active and the ambient temperature is above freezing, partial and 100% Free-Cooling operating hours can be significantly increased. This allows the refrigeration compressors to be turned off for longer periods of time, in addition to the improved summer air cooled efficiency described above. The Adiabatic System is controlled & protected by the proprietary Motivair chiller PLC software and is completely automatic including auto fill, winter drain down, low water level and anti-freeze alarms. MLC-FC 1200 with Adiabatic System

MLC & MLC-FC CONTROLS PLC CONTROLS The MLC range features the PCO3 control system, which is an advanced Programmable Logic Controller, with a base-operating platform that can be easily modified to adapt to various applications. A multi-character LCD display, and easy to follow directional prompts, gives the operator complete control over all chiller functions. Multiple digital and analog inputs as well as digital and PWM outputs offer unparalleled control possibilities. Control features of the PCO3 include: PC03 Display PC03 Board n Highly visible LCD display n Tactile push-buttons n Adjustable alarm set points n F/ C selectable n Compressor Lead/Lag control n Anti-Compressor short cycle n Compressor failure alarm n Adjustable water set point n Supply water temp. display n Return water temp. display n Low water temperature alarm n Freeze alarm n Low water/glycol flow alarm n High water temperature alarm n Low refrigeration pressure alarm n High refrigeration pressure alarm n Irregular voltage alarm n General Alarm Relay n Remote Start/Stop Relay n Manual alarm reset n RS 232/RS 485 communication n Ethernet Communication n LON, BACNET, MODBUS communication (optional) INTELLIGENT CHILLER RESPONSE The Latest generation of Motivair software allows the chillers to respond to system changes in real time and to adjust performance accordingly. The proprietary control logic in the MLC & MLC-FC chillers provides: n Automatic restart after a power outage n Rapid restart of refrigeration compressors after a power outage, while affording maximum compressor protection n Selective decision on which compressor(s) to start first based on run-time and fastest possible response to system load n Liquid injection to the compressors under high ambient operation n Seamless transition between refrigeration and optional Free Cooling mode based on system load, chilled water temperature, ambient temperatures and installation profile.

MLC & MLC-FC SPECIFICATIONS MLC & MLC-FC CHILLER RANGE WITH SCREW COMPRESSORS MLC 200 270 340 390 510 600 660 820 930 1100 1150 1200 1400 1600 1750 NOMINAL COOLING CAPACITY EWT 54 F LWT 44 F AMB 95 F Tons 58 72 84 110 127 176 200 233 260 299 328 350 400 466 520 MLC-FC 100% FREE COOLING AMBIENT TEMP. o F 32.0 30.3 29.1 27.0 25.5 26.8 25.0 24.1 25.2 20.5 21.1 21.2 25.0 24.1 25.2 REFRIGERATING CIRCUIT Qty. 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 SCREW COMPRESSOR Qty. 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 CAPACITY STEPS (PER COMPRESSOR) Qty. 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 FANS / CONDENSER MLC ELECTRONIC FAN SPEED CONTROL Qty. 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 MLC TOTAL CONDENSER AIR FLOW CFM 40,100 40,700 50,800 58,300 89,500 97,700 141,300 134,300 150,700 181,300 200,100 217,800 282,600 268,600 301,400 MLC FANS Qty. 4 4 6 6 10 10 14 14 16 18 20 22 28 28 32 MLC FANS TOTAL NOMINAL POWER HP 9 9 13 13 22 22 31 31 35 40 44 48 62 62 70 MLC-FC ELECTRONIC FAN SPEED CONTROL Qty. 2 2 2 2 2 2 2 2 2 2 2 2 4 4 4 MLC-FC TOTAL CONDENSER AIR FLOW CFM 68,864 68,040 67,686 89,464 88,051 131,841 156,562 155,738 178,928 198,115 239,551 235,667 313,124 311,476 357,856 MLC-FC FANS Qty. 6 6 6 8 8 12 14 14 16 18 22 22 28 28 32 MLC-FC FANS TOTAL ABSORBED POWER HP 18 18 18 24 24 36 42 42 48 54 66 66 84 84 96 OPTIONAL PUMP & TANK NOMINAL FLOW GPM 139 172 200 263 301 419 477 553 619 708 781 833 954 1,106 1,238 OPTIONAL PUMP PRESSURE PSI 39.2 43.5 30.5 33.4 33.4 35.5 36.3 43.5 40.6 45 37.7 46.4 NA NA NA OPTIONAL PUMP ABSORBED POWER HP 7.5 10 10 15 15 25 25 30 30 40 50 60 NA NA NA OPTIONAL PUMP ABSORBED CURRENT A 11 14 14 21 21 34 34 40 40 52 65 77 NA NA NA FLANGED CHILLED WATER CONNECTIONS IN 4" 4" 4" 5" 5" 6" 6" 6" 8" 8" 8" 8" 8" 8" 8" OPTIONAL TANK VOLUME gallons 132 132 132 132 132 132 176 176 N/A N/A N/A N/A NA NA NA ELECTRICAL DATA POWER CIRCUIT V/Ph/Hz 460/3/60 (575/3/60 Optional) AUXILIARY CIRCUIT V/Ph/Hz (230-24)/1/60 MLC FULL LOAD AMPS (FLA)* A 103 132 149 188 236 305 349 419 453 549 602 627 698 838 906 MLC MINIMUM CIRCUIT AMPACITY (MCA)* A 114 147 166 209 262 339 387 466 504 612 671 698 735 884 955 MLC MAXIMUM OVERCURRENT PROTECTION (MOP)* A 160 208 232 294 365 477 542 655 707 860 943 979 883 1,067 1,151 MLC-FC FULL LOAD AMPS (FLA)* A 112 136 155 206 237 320 360 427 468 539 597 636 698 838 906 MLC-FC MINIMUM CIRCUIT AMPACITY (MCA)* A 123 150 171 228 263 354 398 474 519 597 661 705 735 884 955 MLC-FC MAX. OVERCURRENT PROTECTION (MOP)* A 167 207 236 316 366 359 551 660 723 832 917 981 883 1,067 1,151 NOISE DATA MLC SOUND PRESSURE LEVEL** dba 61 63.2 63.3 64.6 64.9 67.8 69.1 70.5 71.1 71.4 72.1 72.1 74 74.6 77 MLC-FC SOUND PRESSIRE LEVEL** dba 60.3 62.8 63.5 63.9 64.2 67.2 68.2 70 70.5 70.8 71.1 71.4 74 74.6 77 DIMENSIONS AND WEIGHTS MLC Length IN 118 118 157 157 197 197 260 260 295 354 394 394 544 544 614 MLC Width IN 118 118 157 157 197 197 260 260 295 354 394 394 544 544 614 MLC Height IN 96 96 96 96 96 96 96 96 96 96 96 96 96 96 96 MLC-FC Length IN 157 157 157 195 195 270 307 307 344 382 457 457 544 544 614 MLC-FC Width IN 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 MLC-FC Height IN 87 87 87 87 87 87 87 87 87 87 87 87 87 87 87 MLC Weight - Installed* LBS 7,880 8,460 9,510 10,060 11,320 12,570 14,400 15,190 16,230 17,510 20,200 20,650 30,300 31,880 33,960 MLC-FC Weight Installed* LBS 8,067 9,282 9,835 12,045 12,376 16,023 16,907 17,680 21,216 23,205 26,520 27,625 35,314 36,860 36,860 * Does not include optional pump or tank ** Distance measured in an open field at 33 feet from condenser MLC CAPACITY CORRECTION CHART Capacity Correction Factors (cf) (Multiply catalog capacities by correction factors) Chilled Water Temp. ( F) 23 32 40 45 50 55 60 cf1 F 0.63 0.77 0.93 1 1.1 1.2 1.3 Ambient Temp. ( F) 85 90 95 100 Consult Motivair cf2 F (MLC) 1.06 1.03 1 0.96 Glycol % (by weight) 0 10 20 30 40 50 Consult cf4 1 0.99 0.98 0.97 0.96 0.94 Motivair 2012 Motivair Corporation. Motivair reserves the right to modify specifications without notice. Reproduction of this brochure in whole or part is prohibited.

APPLICATION, INTEGRATION & SOLUTIONS FOR ALL YOUR COOLING NEEDS: MPC & MPC-FC 1/2-50 ton packaged air-cooled or water-cooled chillers for Industrial cooling, Medical cooling or custom HVAC applications. Includes integrated microprocessor, pump station, and storage reservoir. MHR & MHP 15-500 ton air-cooled or water cooled chillers with Simultaneous Heat Recovery or Heat Pump option. MHP Reversible air-to-water heat pump chillers from 15-240 tons. Available with primary circulation pumps, low noise package and simultaneous heat recovery. MCD Chilled Door Advanced rack cooling system fits any standard or OEM computer rack. Removes up to 45 kw of heat per door. Enhanced performance with Free Cooling chillers. PTS Pump/Tank Stations for chillers and cooling systems. MOT & MEC Open draft or closed loop evaporative cooling towers for process cooling or HVAC applications. MFC Closed loop dry-coolers for process cooling and remote Free-Cooling applications. Printed on Recycled Stock with 10% Post Consumer Fiber. 0090102 85 Woodridge Drive Amherst, NY 14228 Tel: 716-691-9222 Fax: 716-691-9229 www.motivaircorp.com