Lifting Plants Product Overview

Similar documents
Automatic Waste Water Lifting Unit. Ama-Drainer-Box Mini. Type Series Booklet

Data sheet: Wilo-RainSystem AF Comfort MC 304

Sekamatik series PREFABRICATED LIFTING STATIONS FOR RESIDENTIAL, COMMERCIAL OR INDUSTRIAL APPLICATIONS

mini-compacta Type Series Booklet

Automatic Waste Water Lifting Unit

MULTISAN Fully automatic sewage and waste water pump

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

SL EX.4.51D

Trusted Expertise in Domestic and Commercial Wastewater

Cleaning System. Amajet. Type Series Booklet

JUNG PUMPEN LIFTING STATIONS

SL S.S.N.51D

Company name: Created by: Phone:

74 Catalogue 3.1. Wastewater lifting stations

3 Wastewater lifting stations

Lifting Station Type ABS Sanimax

GRUNDFOS PRODUCT GUIDE. Unilift CC, KP, AP. Submersible wastewater pumps 60 Hz

Choosing the Right Pump

INSTALLATION AND OPERATING INSTRUCTIONS

GRUNDFOS. Multilift PRODUCTS. MSS, M, MOG, MD, MLD, MDG and MD1/V

SUBMERSIBLE PUMPS For water with particulate matter 2 pole - 50 Hz 2 ranges : SS 304 & SS 316 L

HL Anti-flooding valves 5/4" DN40 = DN32 = DN32 = DN40 = 280 DN32 DN32 = 350 DN40 DN40 = 350 DN32 = 90 DN40 = 95

DRAINAGE AND SEWAGE. DRENA-LINE Residential Technology

Technical data. Unilift KP. CRUNDFOS "~ ozpump.com.au Drainage pumps. Unilift KP

APPLICATIONS. For the accelerated circulation of hot water in heating circuits with duty point optimisation

POWER and INTELLIGENCE

Sanitary Drainage Systems

2016 Plumbing Supplemental Plan Review List

Protection and Control of Solid Fuel Boilers

ABS lifting station Sanimax

RAINWATER FILTERS AND REUSE OF RAINWATER

- Sewage and Sludge Pumps

X1 series Submersible Drainage Pump

Submersible Pumps. New Style Submersible Pumps. With closed-loop cooling system. Non-Clogging Type CNX Series

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

Instruction manual. Submersible sump pump. Safety instructions Application Electrical connection Installation Maintenance Technical data

Specially Designed Waste Water & Sewage Pumps

FEATURES. Other Fed-Flush Arrangements

KESSEL Grease separator M NG 2, 4, 7 and 10 For installation in frost free areas With manually automated disposal program

SSA Serie. Features. Model code. Applications. Performance Curves. Operation Conditions. Materials

Stuart Turner has an engineering heritage dating back to 1906 and continues to manufacture from its original site

Safe, precise and cost-effective dosing with ProMinent Low-pressure dosing pumps up to 1,000 l/h

Building Utilities 1 Plumbing and Sanitary Systems

Summary of BBS Proposed Ohio Plumbing Code Rule Changes October 2016

CHAPTER 10 TRAPS AND INTERCEPTORS

CAP SERIES SEWAGE AND WASTE WATER PUMPS

Lecture : Introduction to building services I - Plumbing & Drainage Services 22 September 2016

Dewatering Solutions for the Real World In the real world time is money, and worksites have no time for unwanted water. Sulzer has the solutions in a

catalogue made in Germany Sanitary Installations Water Sewage Industry

NEWS 2017 SANIFLO. Pumps and pumping stations

The easy solution for waste water removal

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

SOLOLIFT2. Grundfos bring you a macerator that is the most powerful, reliable and service friendly on the market, delivered by a name you can trust

GARCIA GALUSKA DESOUSA Consulting Engineers

Process engineering. Collection and disposal of commercial food waste ACO Waste-Jet Wet refuse collection system

aquaconcept Cold water

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP

Macerator Pumps & Lifting Station. Technical presentation Part 1

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz

AIR HANDLING UNITS ASSET REFERENCE: DESIGN AHU 1 AHU 2

RESOLUTION NO WHEREAS the City of Kalama reviews annually and sets fees for services by resolution of the City Council;

Product Catalog. Condensate Removal Ice Machine Replacement Evaporative Cooler Accessories. Engineered Products HVAC. Industrial

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

General Overview 2009

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

Installation, Operating and Maintenance Instructions

SXS. CIRCULATING PUMPS FOR COLLECTIVE APPLICATIONS Domestic hot water Bronze housing 2 poles 50 Hz 230 V OPERATING RANGES APPLICATIONS BENEFITS

RainHarvesting Systems Brochure 2011

Designs of domestic bathrooms, guidance and advice from

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

Smarter. Easier. Faster. Product Guide

Wastewater pumps 3045, For groundwater and sewage

CBU144. Compact Booster Unit - single pump To ensure the quality of potable water according to EN1717. Product specification sheet

The new SOLOLIFT2 means goodbye to dirty hands

KESSEL Grease separator EasyClean free Standard, Direct - oval in NS 2, 4, 7, 10, 15, 20, 25, 30 for set-up in frost-free rooms

Greenleaf 400 Macerator Toilet Waste Pump Instruction Manual

Submersible Dewatering Pumps

Flygt centrifugal grinder pumps

PORTABLE HYDRANT PN10 1A; 2A; 1B; 2B; 1C; 2C TYPES

Progressive Cavity Sewer Systems

COMMERCIAL PERMIT APPLICATION AND CHECKLIST. Depending on the scope of your project, the following submittal requirements will apply:

PLUMBING INSTALLATIONS

INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE (GB)

Pressure Boosting Solutions

CR20-07 A-F-A-E-HQQE 3x400/ HZ

INLINE СENTRIFUGAL FAN BOX BOX-R OPERATION MANUAL

CHAPTER 10 TRAPS AND INTERCEPTORS The vent pipe opening from a soil or waste No more than one (1) approved slip joint

Group SANIFLO. The solution to install a WC, a bathroom or a kitchen anywhere you want MADE IN FRANCE

Heating, air-conditioning, cooling

CRAFTSMAN EXAMINATION, NOVEMBER 2009 PLUMBING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

CHAPTER 10 TRAPS AND INTERCEPTORS TABLE 10-1 HORIZONTAL LENGTHS OF TRAP ARMS (EXCEPT FOR WATER CLOSETS AND SIMILAR FIXTURES) 1, 2

Submersible Grinder Pump Type ABS Piranha S10 - PE125

HIGH EFFICIENCY CIRCULATORS. Represented by Taconova Group AG CATALOGUE 2018 EN. easyuse. greatperformance

SUPPLEMENTARY INSTRUCTIONS

USING YOUR PRESSURE SEWER SYSTEM

INLINE CENTRIFUGAL FAN. Centro-M OPERATION MANUAL

Affordable efficiency!

1 Declaration of conformity

Transcription:

Wilo-DrainLift Con Duty chart (-pole, 5 Hz) 5 Wilo-DrainLift Con Lifting Plants Product Overview Wilo-DrainLift Lifting Plants Condensate lifting plants Removal of condensate, can be used in Condensing boiler applications Air conditioning and refrigeration systems (such as refrigerators and evaporators) 5 5 5 Q [l/h] Lifting Plants Wilo-DrainLift Lifting Plants Product Overview Duty chart (-pole, 5 Hz) 7 5 Wastewater lifting plant (above-floor Wilo-Drain TMP installation) Automatic drainage for showers, washstands, washing machines and dishwashers etc. Pumping rain, wastewater and drainage water which does not contain faeces, fibrous materials, oils or fatty wastes. 5 7 8 Q[m /h] Wilo-DrainLiftBox Duty chart (-pole, 5 Hz) 8 Wilo-DrainLift Box Wastewater lifting plant For underground installation, can be used in Areas at risk of flooding Garage entrances Basement hatchways 8 Q [m /h] Wilo-DrainLift FH/D-FH Duty chart (-pole, 5 Hz) 8 Wilo-Drain FH/D-FH Wastewater lifting plant Removal of water which does not contain faeces, can be used in Underground car parks Pubs and inns Commercial buildings 5 5 5 Q[m /h] Wilo-DrainLift KH Duty chart (-pole, 5 Hz) Wilo-DrainLift KH -, Mini Sewage Lifting Plant For limited use (directly connected behind a toilet) with macerator for disposal of wastewater from one toilet together with one hand washing stand, one shower, or one bidet. Q[m /h] As of: / - Subject to change without prior notice

Lifting Plants Product Advantages Wilo-DrainLift Lifting Plants Wilo-DrainLift Con Low-noise operation inlet openings Standard alarm contact Easy to install Variable inlets/discharges Modern design Shower drain possible from heights of mm Low-noise operation via integrated submersible Product Advantages Lifting plants Wilo-DrainLiftBox Easy to install due to built-in and non-return valve Large tank volume Easy to maintain Removable s with pressure line Wilo-DrainLift FH/DFH Increased reliability with: Large collector tank Large free ball passage Switchgear with collective fault signal and battery-powered alarm Wilo-DrainLift KH Modern, compact design Straightforward installation with self-sealing, direct toilet connection As of: / - Subject to change without prior notice 5

, Wilo-DrainLift Box, FH/D-FH Product Description Wastewater lifting plant (above-floor installation) Type key Example: Wilo-TMP -.5 EM TMP Wastewater lifting plant (above-floor) Nominal diameter of delivery connection (DN / G / ).5 Rated motor power [kw] EM AC ~ V, 5 Hz Applications Wastewater lifting plant for the automatic drainage of showers, washstands, washing machines, dishwashers etc. in old or new buildings where wastewater cannot be fed to the main sewers by natural gravity flow or disposal of wastewater from below the backflow level. Suitable for handling drainage water that is free of faecal and fibrous matter, non-aggressive rainwater, wastewater and drainage water that is free of fats and oils. The specifications of DIN EN 5- and DIN 98- must be complied with. Note: Handling of sewage that contains faeces in wastewater lifting plants is not permitted. For these applications, we recommend using the Wilo-DrainLift S-XXL series sewage lifting plants. Design Fully assembled, automatically switching wastewater lifting plant with all required switching and control equipment and built-in nonreturn valve. TMP : Active carbon filter with overflow protection for air intake and exhaust, inlet ports DN at different height levels, discharge port DN (G / ). The ventilation can also be guided to above roof level with a self-sealing connecting sleeve (pipe outer diameter 5 mm). TMP : Flexibility for use with inlets possible both on the side and on the top (a particular advantage for retrofitted installations), easy-to-maintain system construction with built-in TMW, DN discharge port. Wilo-DrainLift Box Submersible wastewater plant Type key Example: Wilo-DrainLift Box /8 Box Wastewater lifting plant Nominal diameter of delivery connection (DN, Ø ) 8 Max. delivery head [m] Applications Drainage of flood-endangered rooms, garage entrances and basements and basement hatchways as well as showers, washbasins etc. in old and new buildings fur sub-floor installation. Design Automatically switching lifting plant with built-in submersible. Ready-to-install for sub-floor applications. Flexibility for use with three inlet options in DN, of which one inlet can be used for connection to another tank. Scope of delivery Fully installed and assembled with attached float switch in an impact-proof plastic container for sub-floor installation. Completely ready-to-operate with installed pressure line and non-return valve. Pump cable (5 m or m long) with attached Schuko plug. Installation and operating manual., Wilo-DrainLift Box, FH/D-FH Product Description Scope of delivery Fully assembled, automatically switching wastewater lifting plant with active carbon filter (for TMP ) and installation and operating manual. As of: / - Subject to change without prior notice

, Wilo-DrainLift Box, FH/D-FH Pump Equipment/Function Pump Equipment/Function = available, = not available DrainLift TMP -.5. EM DrainLift TMP /8 DrainLift Box DrainLift Box Pump/motor seals In ing medium area: Mechanical seal Oil seal chamber Design Pump position Submersible in tank Single- plant Double- plant Free-flow impeller DrainLift FH/D-FH Patented turbulator Materials Motor Stainless steel Hydraulic housing Plastic PP-GF PP-GF Cast iron EN-GJL- Tank Plastic ABS PE PE PE PE Equipment Motor Temperature (WSK) monitor Level control Float switch Pneumatic pressure sensor Alarm Battery-operated Detachable cable Type-dependent Pre-assembled Built-in check valve body Inlet seal Installation kit for pressure line connection Mounting hardware Active carbon filter As of: / - Subject to change without prior notice

, Wilo-DrainLift Box, FH/D-FH Technical Data Wilo-DrainLift... Technical Data TMP -.5. EM TMP /8 Box /8 Box / Box / Approved fluids Domestic sewage not containing faeces Domestic sewage containing faeces Washing machine soap and water mixture (without longfibre particles) Non-chlorinated shower and bath water Strongly alkaline condensate Electrical connection Mains connection [V] ~ ~ ~ ~ ~ Connected load P [kw]..5.5.75.9 Rated motor power P [kw].5.7.7.55. Rated current [A].5.... Mains frequency [Hz] 5 5 5 5 5 Cable length from plant to switchgear/plug [m]..5 5 Permissible range of application Operating mode S ( h) S -5% S -5% S -5% S -5% Max. frequency switching[per hour] Max. permitted pressure in the pressure line [bar]..... Fluid temperature, max. [ C] 5 5 5 5 5 Fluid temperature, short periods up to min. [ C] 75 9 9 9 Connections Delivery connection [mm] Inlet connection [mm] Ø (G / ) ( x G / ) Ø Ø Ø Ø 5// Vent line [mm] 5 Motor Insulation class F F F F B Protection class IP IP 7 IP 7 IP 7 IP 7 Dimensions/weights Gross volume [l] 7 85 85 85 Switching volume [l]. 5 Weight [kg] 7. 8. 8 Lifting plants = available or authorised, = not available or not authorised As of: / - Subject to change without prior notice 5

Pump Curves TMP -,5. -pole, 5 Hz [m] 5 Wilo-Drain-TMP Pump Curves In accordance with EN 5-.., a flow velocity (in the pressure line) of between.7 and. m/s is to be maintained. H Q[m /h],5 [l/s] Q TMP /8 -pole, 5 Hz Lifting plants [m] 8 Wilo-Drain-TMP /8 In accordance with EN 5-.., a flow velocity (in the pressure line) of between.7 and. m/s is to be maintained. H 8,5,5,5 [m /h] [l/s] Q As of: / - Subject to change without prior notice 7

Dimension Drawings, Installation Example Dimension drawings Dimension Drawings, Installation Example TMP -,5. 98 5 A Rear view B Front view = Inlet DN = Inlet DN (shower) = Discharge port G / (DN ) = Vent line DN 5 5 A 8,5 55,5 5 B TMP /8 85 5 9 = Pressure line DN = Vent line DN = Inlet DN (wash basin) = Inlet DN 5 (washing machine) 5 = Inlet DN (shower) 75 5 5 5 78 75 Typical installation scheme TMP / Wilo-Opti-Drain-Box- TM P -,5 E M : Pressure line : Vent line (optional) :5 DN :5 8 (TMP /8) (TMP ) Wilo-Drain TMP -,5 EM 8 As of: / - Subject to change without prior notice