Wilo-DrainLift Con Duty chart (-pole, 5 Hz) 5 Wilo-DrainLift Con Lifting Plants Product Overview Wilo-DrainLift Lifting Plants Condensate lifting plants Removal of condensate, can be used in Condensing boiler applications Air conditioning and refrigeration systems (such as refrigerators and evaporators) 5 5 5 Q [l/h] Lifting Plants Wilo-DrainLift Lifting Plants Product Overview Duty chart (-pole, 5 Hz) 7 5 Wastewater lifting plant (above-floor Wilo-Drain TMP installation) Automatic drainage for showers, washstands, washing machines and dishwashers etc. Pumping rain, wastewater and drainage water which does not contain faeces, fibrous materials, oils or fatty wastes. 5 7 8 Q[m /h] Wilo-DrainLiftBox Duty chart (-pole, 5 Hz) 8 Wilo-DrainLift Box Wastewater lifting plant For underground installation, can be used in Areas at risk of flooding Garage entrances Basement hatchways 8 Q [m /h] Wilo-DrainLift FH/D-FH Duty chart (-pole, 5 Hz) 8 Wilo-Drain FH/D-FH Wastewater lifting plant Removal of water which does not contain faeces, can be used in Underground car parks Pubs and inns Commercial buildings 5 5 5 Q[m /h] Wilo-DrainLift KH Duty chart (-pole, 5 Hz) Wilo-DrainLift KH -, Mini Sewage Lifting Plant For limited use (directly connected behind a toilet) with macerator for disposal of wastewater from one toilet together with one hand washing stand, one shower, or one bidet. Q[m /h] As of: / - Subject to change without prior notice
Lifting Plants Product Advantages Wilo-DrainLift Lifting Plants Wilo-DrainLift Con Low-noise operation inlet openings Standard alarm contact Easy to install Variable inlets/discharges Modern design Shower drain possible from heights of mm Low-noise operation via integrated submersible Product Advantages Lifting plants Wilo-DrainLiftBox Easy to install due to built-in and non-return valve Large tank volume Easy to maintain Removable s with pressure line Wilo-DrainLift FH/DFH Increased reliability with: Large collector tank Large free ball passage Switchgear with collective fault signal and battery-powered alarm Wilo-DrainLift KH Modern, compact design Straightforward installation with self-sealing, direct toilet connection As of: / - Subject to change without prior notice 5
, Wilo-DrainLift Box, FH/D-FH Product Description Wastewater lifting plant (above-floor installation) Type key Example: Wilo-TMP -.5 EM TMP Wastewater lifting plant (above-floor) Nominal diameter of delivery connection (DN / G / ).5 Rated motor power [kw] EM AC ~ V, 5 Hz Applications Wastewater lifting plant for the automatic drainage of showers, washstands, washing machines, dishwashers etc. in old or new buildings where wastewater cannot be fed to the main sewers by natural gravity flow or disposal of wastewater from below the backflow level. Suitable for handling drainage water that is free of faecal and fibrous matter, non-aggressive rainwater, wastewater and drainage water that is free of fats and oils. The specifications of DIN EN 5- and DIN 98- must be complied with. Note: Handling of sewage that contains faeces in wastewater lifting plants is not permitted. For these applications, we recommend using the Wilo-DrainLift S-XXL series sewage lifting plants. Design Fully assembled, automatically switching wastewater lifting plant with all required switching and control equipment and built-in nonreturn valve. TMP : Active carbon filter with overflow protection for air intake and exhaust, inlet ports DN at different height levels, discharge port DN (G / ). The ventilation can also be guided to above roof level with a self-sealing connecting sleeve (pipe outer diameter 5 mm). TMP : Flexibility for use with inlets possible both on the side and on the top (a particular advantage for retrofitted installations), easy-to-maintain system construction with built-in TMW, DN discharge port. Wilo-DrainLift Box Submersible wastewater plant Type key Example: Wilo-DrainLift Box /8 Box Wastewater lifting plant Nominal diameter of delivery connection (DN, Ø ) 8 Max. delivery head [m] Applications Drainage of flood-endangered rooms, garage entrances and basements and basement hatchways as well as showers, washbasins etc. in old and new buildings fur sub-floor installation. Design Automatically switching lifting plant with built-in submersible. Ready-to-install for sub-floor applications. Flexibility for use with three inlet options in DN, of which one inlet can be used for connection to another tank. Scope of delivery Fully installed and assembled with attached float switch in an impact-proof plastic container for sub-floor installation. Completely ready-to-operate with installed pressure line and non-return valve. Pump cable (5 m or m long) with attached Schuko plug. Installation and operating manual., Wilo-DrainLift Box, FH/D-FH Product Description Scope of delivery Fully assembled, automatically switching wastewater lifting plant with active carbon filter (for TMP ) and installation and operating manual. As of: / - Subject to change without prior notice
, Wilo-DrainLift Box, FH/D-FH Pump Equipment/Function Pump Equipment/Function = available, = not available DrainLift TMP -.5. EM DrainLift TMP /8 DrainLift Box DrainLift Box Pump/motor seals In ing medium area: Mechanical seal Oil seal chamber Design Pump position Submersible in tank Single- plant Double- plant Free-flow impeller DrainLift FH/D-FH Patented turbulator Materials Motor Stainless steel Hydraulic housing Plastic PP-GF PP-GF Cast iron EN-GJL- Tank Plastic ABS PE PE PE PE Equipment Motor Temperature (WSK) monitor Level control Float switch Pneumatic pressure sensor Alarm Battery-operated Detachable cable Type-dependent Pre-assembled Built-in check valve body Inlet seal Installation kit for pressure line connection Mounting hardware Active carbon filter As of: / - Subject to change without prior notice
, Wilo-DrainLift Box, FH/D-FH Technical Data Wilo-DrainLift... Technical Data TMP -.5. EM TMP /8 Box /8 Box / Box / Approved fluids Domestic sewage not containing faeces Domestic sewage containing faeces Washing machine soap and water mixture (without longfibre particles) Non-chlorinated shower and bath water Strongly alkaline condensate Electrical connection Mains connection [V] ~ ~ ~ ~ ~ Connected load P [kw]..5.5.75.9 Rated motor power P [kw].5.7.7.55. Rated current [A].5.... Mains frequency [Hz] 5 5 5 5 5 Cable length from plant to switchgear/plug [m]..5 5 Permissible range of application Operating mode S ( h) S -5% S -5% S -5% S -5% Max. frequency switching[per hour] Max. permitted pressure in the pressure line [bar]..... Fluid temperature, max. [ C] 5 5 5 5 5 Fluid temperature, short periods up to min. [ C] 75 9 9 9 Connections Delivery connection [mm] Inlet connection [mm] Ø (G / ) ( x G / ) Ø Ø Ø Ø 5// Vent line [mm] 5 Motor Insulation class F F F F B Protection class IP IP 7 IP 7 IP 7 IP 7 Dimensions/weights Gross volume [l] 7 85 85 85 Switching volume [l]. 5 Weight [kg] 7. 8. 8 Lifting plants = available or authorised, = not available or not authorised As of: / - Subject to change without prior notice 5
Pump Curves TMP -,5. -pole, 5 Hz [m] 5 Wilo-Drain-TMP Pump Curves In accordance with EN 5-.., a flow velocity (in the pressure line) of between.7 and. m/s is to be maintained. H Q[m /h],5 [l/s] Q TMP /8 -pole, 5 Hz Lifting plants [m] 8 Wilo-Drain-TMP /8 In accordance with EN 5-.., a flow velocity (in the pressure line) of between.7 and. m/s is to be maintained. H 8,5,5,5 [m /h] [l/s] Q As of: / - Subject to change without prior notice 7
Dimension Drawings, Installation Example Dimension drawings Dimension Drawings, Installation Example TMP -,5. 98 5 A Rear view B Front view = Inlet DN = Inlet DN (shower) = Discharge port G / (DN ) = Vent line DN 5 5 A 8,5 55,5 5 B TMP /8 85 5 9 = Pressure line DN = Vent line DN = Inlet DN (wash basin) = Inlet DN 5 (washing machine) 5 = Inlet DN (shower) 75 5 5 5 78 75 Typical installation scheme TMP / Wilo-Opti-Drain-Box- TM P -,5 E M : Pressure line : Vent line (optional) :5 DN :5 8 (TMP /8) (TMP ) Wilo-Drain TMP -,5 EM 8 As of: / - Subject to change without prior notice