SkyStar SK-ECM. Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board

Similar documents
SkyStar SK. Cassette Fan Coil Unit with Asynchronous Motor

Product is subject to and complies with Regulation (UE) N.327/2011. cert. n Fan Coil Unit Cassette SkyStar Jumbo ECM. technical catalogue

consumption ECM motors NEW Low energy Cassette Fan Coil Units YHK ECM YHK

Carisma Fly. Made in. Italy. Wall-mounted Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT.

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

NEW. SkyStar SkyStar ECM. Cassette Fan Coil Units. consumption ECM motors. Low energy. Air Conditioning ENVIRONMENTAL COMFORT

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

NEW. Wall Controls. Air Conditioning Ceiling Air Conditioning Elegant. Cert. n 0545

Application guide. ARMONIA ARMONIA EC 1,3-11 kw. Chilled water cassette Chilled water cassette - EC motor ARMONIA-AGU-1010-E

NEW. communication protocol. Control board with Modbus. Air Conditioning SkyStar SkyStar ECM Cassette Fan Coil Units

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

Energy. The Energy ducted units have been designed. Heat Recovery Unit

NEW. MB control board. communication protocol. for Modbus. Air Conditioning Carisma CRSO High Pressure Fan Coil Units

The Sabiana. of Fan Coil

UniTrane Terminals. High Wall Fan Coil: W-Line Ducted Fan Coil: D-Line Blower coil: B-Line. Product Presentation September 2016

YFCN Fan Coil Unit centrifugal fan

Helios. Unit Heater. Thickness 1 mm. Diameter 22 mm. Pitch 2,5 mm. Fin 0,12 mm

QZHW Fan Coil Unit. Key features. Specifications

NEW GREEN TECHNOLOGY

ECM Technology. Technology. Features. Advantages (compared to traditional brushed motors) Power consumption: YFCN versus YFCN-ECM (W/kW)

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Futura Fan Coil Units ICIM

UniTrane Ductable Units D-line and B-Line

SKYSTAR water cassette Main components:

QZB "Standard" comfort fan coil

Conditioning your ambient, maximising your comfort.

QFDK "ägir II" chilled water cassette

Air Conditioning Carisma CRS High Pressure Fan Coil Units.

AIR DESIGN WATER ITALIA CARISMA COLLECTION

Bi2 4tubes * SLR 4T Fan coil radiator for heating and cooling at the same time. FEATURES. Cools, Dehumidifies, Heats and Filters

COMFORT HYDRONIC TERMINALS

Conditioning your ambient, maximising your comfort.

Heating / Air Conditioning Energy Heat Recovery Units ENVIRONMENTAL COMFORT

COMFORT APPLICATION HYDRONIC TERMINALS ELEGANCE AND DESIGN FOR YOUR RESIDENTIAL COMFORT

DUCTED UNITS EBH EDS INTEGRATED COMFORT SYSTEMS

QTS SELECTION TECHNICAL BOOKLET

PRODUCT GUIDE

ART-U 1-4 kw. Design fan coil unit with a minimum depth of 10 cm only and BLDC motor. Fan coil ART-U PLUS. Design-driven innovation NEW

Technical Manual. New Water Cassette. Series BREZZA DOUBLE

Blower-YEFB-020-3R-1maxVel

Galletti IWC THE HYDRONIC CASSETTE UNIT PAR EXCELLENCE A guide to choosing Create value to design better

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

SIGMA PRISMA LOW BODY CONCEALED

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

CASSETTE UNIT. Comfort Circle

FAN COIL UNITS LASER / LOW BODY / CONCEALED

KOG LN. Low Noise Chilled Water Cassettes Models 09, 12 & to 6.10kW to 5.10kW. 330 to 920 m3/h

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

Aerslim Fancoil unit. Technical information manual. Western Airconditioning B.V. Tel. +31 (0)

UCS UCS/M UCS/H UCS900

Comfort. COMFORT Sabiana circular unit heaters, for ceiling installation only,

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

MORE VALUE TO YOUR WELL-BEING

technical data Fan coil unit FWB small duct unit

FCX FAN COIL SILENT & EFFICIENT. Floor, ceiling & ducted installation Applicable with VMF management system, Plasmacluster filter option

Fan Coil Range HYDRONIC TERMINALS

Also available with the new i-life R-Slim inverter and radiant panel version. Perfect comfort. Silent operation. Real energy savings

next evo cw next evo cw rcgroupairconditioning

SIMPLICITY OR FULL MODULARITY?

CHAPTER 6 CONDENSING UNITS

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Galletti Water chillers and heat pumps catalogue

Elegance and design for your residential comfort

The technical and dimensional data reported in this manual may be modified in view of any product improvement.

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

4,5 22,5 kw. technicalcatalogue. Air-conditioned server-racks for direct installation into the room T_CLSEVO_0113_GB

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

OMNIA RADIANT FAN COIL WITH RADIANT HEATING PANEL THE FAN COIL FEATURING 3 HEATING MODES

WDH WDH. Ground source heat pumps OTHER VERSIONS ACCESSORIES

Compact and silent Scroll compressors All-season operation

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

NEXT DL NEXT DL. rcgroupairconditioning

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

MHCFC4W Chilled/Hot Water Cassette Fan Coil

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

CWX 3 - CWX 5 CASSETTE TYPE TERMINAL UNIT. Cooling

Technical. Catalogue. NA Version PDWL AECM. LSTAT Series Hydronic EC Ducted Fan Coil

TopVent Design Handbook

LZT High efficiency air to water heat pumps with E.V.I. compressors

ED.X F Kc DIRECT EXPANSION CLOSE CONTROL UNITS WITH REMOTE CONDENSERS AND ADDITIONAL CHILLED WATER FREE COOLING COIL

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

Air cooled industrial chillers

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

GHE Dehumidifiers for radiant cooling systems with heat recovery

Cassette units Model Comfort Circle. - heating - cooling - ventilation

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

CWX 6 - CWX 8 - CWX 10 CASSETTE TYPE TERMINAL UNIT

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

VERTICAL FAN COIL UNITS

CUMULUS CUMULUS. Key figures. Construction. Function Integrated chilled beams

Transcription:

SkyStar SK-ECM Cassette Fan Coil Unit with EC Brushless Electronic Motor and Inverter Board The SkyStar SK-ECM series, available in 5 models, uses an innovative brushless synchronous permanent magnet electronic motor controlled by an inverter board that is directly installed on the unit. The air flow can be varied continuously with a 1-10 V signal from Sabiana controls or by independent contollers (programmable controllers with a 1-10 V output). The extreme efficiency, also at a low speed, makes it possible to greatly reduce in electric consumption (more than 75% less in comparison to a traditional motor) with absorption values, under normal operating conditions, that are no greater than 10 Watt in the entire range. 1

The brushless motoror is characterised by a constant synchronous speed, independently of the applied load, that depends only on the motor power supply frequency, which is modulated by the inverter. It consumes less because: The motor always works at its point of maximum efficiency. In the brushless motor, the rotor s permanent magnets generate the magnetising power autonomously. The motor always operates at the synchronous speed, as a result there are no induced currents that reduce efficiency. The main advantages are: Large reduction in energy consumption, thanks to an optimal response to the thermal load of the environment during every moment of the day. Operating silence at all rotation speeds. bility to operate at any rotation speed. ll the SkyStar SK-ECM units can be supplied in MB version. This version allows a wide range of controls, including the infra-red remote control, which can manage one single unit or several units by using the Modbus RTU - RS 485 communication protocol. 2

Technical characteristics of the main components: ir diffuser: intake grid, frame and adjustable air distribution louvers on each side, made from BS. HT version white BS, RL 9003 HTB version intake grid, frame and louvers in a colour of choice HTC version intake grid and louvers in a colour of choice, plus white BS frame RL 9003 HTD version louvers in a colour of choice, while the grid and frame are made from BS, RL 9003 MD-600 version metal diffuser painted in RL 9003 white colour with 600x600 dimension to perfectly fit into the false ceiling standard modules without overlapping parts (800x800 model is not available) 3

Casing: made from galvanized steel with internal thermal insulation with polyolefin (PO) foam (class M1) and external anti-condensate lining. Control equipment: SK-ECM version: it consists of the pump control circuit board and the inverter circuit board. SK-ECM-MB version: it consists of the MB board Fan assembly: the fan assembly, which (that integrates pump control) and the inverter board. is mounted on anti-vibrating supports, is extremely silent. The radial fan has been designed to optimise performance, using wing profile blades with a shape that reduces turbulence, increasing efficiency and reducing noise. The fans are connected to a three phase permanent magnet brushless electronic motor that is controlled with reconstructed current according to a BLC sinusoidal wave. The inverter board that controls the motor operation is powered by 230 Volt, single-phase and, with a switching systemg, it generates a three-phase frequency modulated, wave form power supply. The electric power supply required for the machine is therefore single-phase with voltage of 230-0 V and frequency of 50-60 Hz. Coil: made of copper tubes with bonded aluminium fins for maximum transfer contact. The coils have 2 or 3 rows for 2 pipe models and 2+1 rows for 4 pipe models (the heating row is on the inside part of the coil). For 4 pipe systems two versions are available: SK 14, SK 44 supply an higher heating emission, SK 26, SK 36, SK 56 supply an higher cooling emission. The coil is not suitable for use in corrosive atmosphere or in environments where aluminium may be subject to corrosion. Condensate collection tray: high density BS polystyrene foam condensate tray, shaped in order to optimize the air diffusion, fire retardant rating B1 to DIN 4102. ir synthetic washable filter, easily removable. Condensate pump: float switch centrifugal pump with 650 mm of maximum head, built into the unit and wired to the control panel on the outside of the casing. Valve set: two or three way valves for ON/OFF operation, with pipe mounting kit and thermostatic actuator. 4

Dimensions and Weight SK 12-14 / SK 22-26 / SK 32-36 (Version 600 x 600) 2 pipe units 3. Flow, heating/cooling 1/2 4. Return, heating/cooling 1/2 4 pipe units 1. Flow, heating 1/2 2. Return, heating 1/2 3. Flow, cooling 1/2 4. Return, cooling 1/2 MD-600 metal diffuser Unit Diffuser MODEL SK 12 SK 14 SK 22-26 SK 32-36 PCKED UNIT kg kg kg kg B C D 28 30 UNPCKED UNIT 22 PCKED UNIT UNPCKED UNIT PCKED UNIT DIMENSIONS (mm) 6 3 790 350 750 150 5

Dimensions and Weight SK 42-44 / SK 52-56 (Version 800 x 800) 2 pipe units 3. Flow, heating/cooling 3/4 4. Return, heating/cooling 3/4 4 pipe units 1. Flow, heating 1/2 2. Return, heating 1/2 3. Flow, cooling 3/4 4. Return, cooling 3/4 Unit Diffuser Unit Diffuser MODEL SK 42 SK 44 SK 52-56 PCKED UNIT UNPCKED UNIT PCKED UNIT UNPCKED UNIT PCKED UNIT DIMENSIONS (mm) kg kg kg kg B C D 44 36 47 10 6 1050 400 1000 200 6

2 pipe units. The following standard rating conditions are used: COOLING (summer mode) Entering air temperature: +27 C d.b. +19 C w.b. Water temperature: + 7 C E.W.T. +12 C L.W.T. HETING (winter mode) Entering air temperature: +20 C Entering water temperature: +50 C Water flow rate as for the cooling conditions Speed MODEL ir flow Cooling total emission (E) Cooling sensible emission (E) Heating (E) Heating - Water 70-60 C Water flow Dp Cooling (E) Dp Heating (E) Sound power Lw (E) Sound pressure Lp ( * ) Fan (E) Water content Dimensions Energy classification FCEER ( ** ) m 3 /h l/h kpa kpa db() db() W l mm (E) Energy classification FCCOP ( *** ) (E) SK ECM 12 SK ECM 22 SK ECM 32 SK ECM 42 SK ECM 52 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 310 1,84 1,35 2,22 3,75 317 4,9 4 5 380 7 1,61 2,67 4,51 373 6,6 5,5 30 8 535 2,75 2,09 3,44 5,82 473 10,1 8,7 47 38 16 310 2, 1,57 2,55 4,28 385 4,6 3,6 5 445 5 7 3,58 6,01 5 9,4 6,6 43 34 11 710 4, 3,18 5, 8,81 744 15,1 13,1 54 45 31 360 2,56 1,81 2,96 4,96 441 5,9 4,7 37 28 7 610 3,87 2,81 4,63 7,79 666 12,4 1 50 41 21 880 5,02 3,74 6,2 10,42 864 19,7 17,7 60 51 62 630 4,21 3 5,11 8,61 723 10,9 8,7 10 870 5,15 3,77 6,35 10,72 885 15,6 12,8 30 17 1165 6, 4,72 8,01 13,54 1089 22,7 19,5 48 710 5,29 3,69 5,89 9,87 909 9,4 7,2 34 25 10 4,0 1130 7,72 5,53 8,83 14,82 1328 18,5 14,9 47 38 32 4,0 1770 10,75 7,94 12,73 21,37 1848,6 28,8 57 48 108 4,0 575 x 575 x 275 820 x 820 x 303 4 pipe units. The following standard rating conditions are used: COOLING (summer mode) Entering air temperature: +27 C d.b. +19 C w.b. Water temperature: + 7 C E.W.T. +12 C L.W.T. HETING (winter mode) Entering air temperature: +20 C Water temperature: +70 C E.W.T. +60 C L.W.T. Speed MODEL ir flow Cooling total emission (E) Cooling sensible emission (E) Water flow Dp Cooling (E) Heating (E) Water flow Dp Heating (E) Sound power Lw (E) Sound pressure Lp ( * ) Fan (E) Cooling water content Heating water content Dimensions Energy classification FCEER ( ** ) m 3 /h l/h kpa l/h kpa db() db() W l l mm (E) Energy classification FCCOP ( *** ) (E) SK ECM 14 SK ECM 26 SK ECM 36 SK ECM 44 SK ECM 56 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 310 1,85 1,34 318 4,6 2,43 209 5,7 5 0,7 380 8 1,6 375 6,2 2,85 5 7,6 30 8 0,7 535 2,77 2,08 476 9,5 3,62 311 1 47 38 16 0,7 310 2,09 9 359 3,5 1,98 170 3,5 5 445 2,81 2,04 483 5,7 2,53 217 5,5 43 34 11 710 3,93 2,95 676 1 3,35 288 9 54 45 31 360 2,38 1 409 4,1 2,2 189 4,5 37 28 7 610 3,53 2,62 608 8,4 6 263 7,5 50 41 21 880 4,53 3,46 779 13,1 3,79 326 11 60 51 62 630 4,3 8 740 9,4 6,14 528 1 10 870 5,28 3,84 908 13,6 7,54 649 15,5 30 17 1165 6,51 4,83 1120 19,8 9,36 805 22,5 48 710 4,98 3,52 856 8,8 5,22 449 6,5 34 25 10 3,6 1,1 1130 7,17 5,2 12 17 7,16 616 11 47 38 32 3,6 1,1 1770 9,87 7,4 1697 30,1 9,51 818 18 57 48 108 3,6 1,1 575 x 575 x 275 820 x 820 x 303 B (E) = Eurovent certified performance. ( * ) = The sound pressure levels are 9 db() lower than the sound power levels and apply to the reverberant field of a 100 m3 room and a reverberation time of 0.5 sec. ) FCEER = Energy classification in Cooling. ) FCCOP = Energy classification in Heating. ( ( ** *** 7

Other available Versions SK-ECM-MB ll the SkyStar ECM units can be supplied in MB version. This version allows a wide range of controls, including the infra-red remote control, which can manage one single unit or several units by using the Modbus RTU - RS 485 communication protocol. MCT The MCT version has been designed for all environments where false ceilings are not featured or cannot be constructed. The cover cabinet fits perfectly to the air intake and outlet diffuser, maintaining the appealing design that defines the SkyStar series. The water fittings can be turned to point upwards. The MCT series includes 7 models, with an installation height of up to 5 m, thanks to the highly flexible adjustment of the air distribution louvers. ll the technical specifications described on the previous pages remain the same, while keeping in mind that the MCT series features one coil only (two pipe systems), there is no possibility of fresh air intake, there is no possibility of additional electric heater. The MCT version features a special casing delivered in separate packaging; this must only be fitted after having installed the SkyStar unit and completed the water and electrical connections. 8

ccessories 3 way ON-OFF valves with micrometric lockshield valve Valve set, 3 ways, ON-OFF, with thermoelectric actuator. The set includes connection pipes and holders. SK 12-14 / 22-26 / 32-36 SK 42-44 / 52-56 2 way ON-OFF valves with micrometric lockshield valve Valve set, 2 ways, ON-OFF, with thermoelectric actuator. The set includes connection pipes and holders. SK 12-14 / 22-26 / 32-36 SK 42-44 / 52-56 3 way ON-OFF valves with simplified kit Valve set, 3 ways, ON-OFF, with thermoelectric actuator. The set includes connection pipes. SK 12-14 / 22-26 / 32-36 SK 42-44 / 52-56 2 way ON-OFF valves with simplified kit Valve set, 2 ways, ON-OFF, with thermoelectric actuator. The set includes connection pipes. SK 12-14 / 22-26 / 32-36 SK 42-44 / 52-56 CD ir distribution connection CP Fresh air connection PRT Fresh air kit This is used to introduce fresh air into the environment directly through the diffuser. 9

CR-T-ECM CR-DI-ECM UPM-ECM UPS-ECM Wall electronic controls SK-ECM version Continuous fan speed control with electronic thermostat and summer/winter switch Continuous fan speed control with electronic thermostat and summer/winter switch Power unit for CR-T-ECM and CR-DI-ECM remote control, fitted on the unit Power unit for CR-T-ECM and CR-DI-ECM remote control, not fitted on the unit T-MB RCS-RT03 RT03 RCS RS PSM-DI Electronic controls SK-ECM-MB version Wall control (to be used with SK-ECM-MB version only) RT03 infra-red remote control with receiver supplied with separate packaging (to be used with SK-ECM-MB version only) RT03 infra-red remote control supplied with separate packaging (to be used with SK-ECM-MB version only) Receiver for RT03 infra-red remote control supplied with separate packaging (to be used with SK-ECM-MB version only) Receiver for RT03 infra-red remote control and MD-600 metal diffuser supplied with separate packaging (to be used with SK-ECM-MB version only) Multifunction control (to be used with SK-ECM-MB version only) Sabianet management system for a network of fan coils Sabianet ROUTER-S SIOS Sabianet (to be used with SK-ECM-MB version only) Router for Sabianet Relay output board for Sabianet T-MB RT03 10

The descriptions and illustrations provided in this publication are not binding: Sabiana reserves the right, whilst maintaining the essential characteristics of the types described and illustrated, to make, at any time, without the requirement to promptly update this piece of literature, any changes that it considers useful for the purpose of improvement or for any other manufacturing or commercial requirements. Sabiana s.p.a. via Piave, 53 20011 Corbetta Milano Italy phone +.02.97203.1 r.a. / +.02.97270429 /+.02.97270576 fax +.02.9777282 / +.02.9772820 www.sabiana.it info@sabiana.it SKE-LT-EN-07-14 11