Speciality Chemicals AGAS MPG PLUS SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES

Similar documents
Green economy with natural refrigerants

Hand pump JP-02. Hand pump JP-02 for acids, alkalies and water-based chemicals. depending on lever position. The telescopic suction tube is adjustable

NOBURST. NOBURST Antifreeze & Heat Transfer Fluid Factory Pre-mixed Freeze Protection for Water-based Heating and Cooling Systems

DOWFROSTTM, DOWCALTM N, DOWTHERMTM SR-1, and DOWCALTM 10

Caractéristiques Unités Valeurs Méthodes. Appearance - Colourless Visual. Density (at 20 C) kg/cm³ 1,52 - Purity % 99,8 -

Gasketed and brazed plate heat exchangers

APPLICATION OF HYDROCARBON REFRIGERANTS IN LOW TEMPERATURE CASCADE SYSTEMS

DEVELOPMENT AND EVALUATION OF HIGH PERFORMANCE, LOW GWP REFRIGERANTS FOR STATIONARY AC AND REFRIGERATION

Table 1. Colorless to yellow liquid Flash Point (Pensky-Martens Closed Cup)

WELCOME TO THE AWT REGIONAL TRAINING PROGRAM

The theory behind heat transfer

NU-CALGON CHEMICAL PRODUCTS

FireFighter Antifreeze

OHMS ENTERPRISE Subsidiary of AIT Synergy Ventures SDN BHD

Duraplus ABS for Secondary Loop Refrigeration Control Systems

FireFighter Antifreeze

Boiler Additives And Filtration

9.3. Inks Closures and Liners Recycle- friendly Problematic Handles and Sport Caps Household Chemical PET

Energy Rating Report

EXTROL EXPANSION TANKS

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

INNOVATION IN DISPENSE

Experience In Motion. DEF Product Support Catalog

Technical Data Sheet for Sunergy SOLAR ENERGY PROCESSOR Model SEP3G10

Glycol Pump Station Medium Temperature Secondary Glycol Refrigeration Systems

Geberit Supply Systems. Mapress and Mepla

A. ASHRAE Handbook HVAC Applications, Snow Melting and Freeze Protection

Section 2: Solar Water Heating Systems focuses primarily on the common solar system design types.

Solar Water Heaters. Bastián Acevedo Bustos. Electronic Engineering Student, Tarapacá University. Environmental Studies Student, York University

Water Heating. Types of Water Heaters It's a good idea to know the different types of water heaters available before you purchase one:

SECTION HYDRONIC PIPING AND SPECIALTIES

CHILLER. Operator s & Installation Manual

Models 65, F65, 150 & F150

Vicot Air Conditioning Co., Ltd. CONTENT

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

Commercial Refrigeration

FULL COMPETENCE IN SPECIAL AND MASS POLYMERS FLUIDIZED BED DRYING AND COOLING FOR POLYMERS AND PLASTICS

ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS

SECTION METERS AND GAGES

CBI 06 QUICK-RELEASE COUPLINGS PLASTIC INDUSTRY APPLICATIONS. Automatic locking. Non spill design. Greater efficiency.

OPERATING AND MAINTENANCE MANUAL

BRINE CHILLER DESCRIPTION

Product Data Sheet. Astro Strip

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

CFF-500 CHILLER. Operator s & Installation Manual. Release Date: November 3, 1996 Publication Number: Revision Date: March 25, 2014 Revision: F

Tradition & Technology

Geberit Supply Systems. Mapress and Mepla

Installation, Operation and Maintenance Manual

INTEGRATED SOLUTIONS BY ICE-CEL. Tube-In-Tank Ice Thermal Storage Systems. Products that perform...by people who care.

The Safest Connections...

PIPING APPLICATION GUIDE

OPERATING INSTRUCTIONS FOR:

SERVICE MANUAL. 300 Series Motorized 35650, 35651, 35652, 36750, 36751, and Model

PLATE HEAT EXCHANGERS FOR MARINE APPLICATIONS

Pipe: ASTM B88, hard drawn copper, Type K. Fittings: ASTM B16.22 Wrought copper and copper alloy.

How to Select and Size a Chiller

Refrigeration Plant Information. We Speak Hockey 365

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

NIBCO Radiant Panel Model RHP-2-4

Heat exchanger plates

SOLARHOT. SuperVox. Description / Applications System Overview. Installation/ Owner s Manual

PRODUCT MANUAL FIRE EXTINGUISHER. Carbon Dioxide 6.5, 9 & 22.5 Kg Capacity Trolley Mounted (45 kg also as a non standard)

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)

BASCO TYPE T and TC MOISTURE SEPARATORS and TRAP. ...world leaders in heat transfer technology

Technical Bulletin Developed with Glow-worm

Basic Radiant Panel Model RHP-2-4

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

Building air conditioning systems using Ice-Cel thermal storage can be designed which cost little or no more than conventional chiller-only systems.

Positively Innovative R32 R32. Instructions for Use and Handling

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

comfort BY CONTROL POOL AND SPA HEATING SOLUTIONS

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

SCHMIDT- BRETTEN GASKETED PLATE HEAT EXCHANGERS

Urea electrical diaphragm pumps

Desiccants & Driers. By Norm Christopherson

STOURFLEX. Technically Advanced Flexible Solutions. A Guide to the Selection of STOURFLEX Pump Connectors

Transformer oil coolers BETA & CETA

Basic Radiant Panel Model RHP-3

Operating Temperature/Pressure Graphs: Flow Sensors

OVERVIEW OF THE ELECTRIC RADIATORS RANGE

The A-series Eletta Flow Monitor with local indication and analog output

FULL RANGE of products for the protection of boilers and water heating loops SLUDGE FILTERS FDM-1P / FDM-2 / FDM-3

Engineering Specifications

Recirculating Cooler SRC14

SB Series Brazed Plate Heat Exchanger Installation Manual

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Installation, Operating and Servicing Instructions

P SERIES PURGEMETERS. Full Coverage for Semi-Conductor Processes for Built-IN Use for Equipment for General Industrial Processes

Northvale Korting Global Contacts

Boiler protection kit guide

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION WATER TREATMENT

COMMERCIAL POOL HEATING SYSTEMS AND COVERS:

PORTABLE HYDRANT PN10 1A; 2A; 1B; 2B; 1C; 2C TYPES

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Induction Furnace Cooling Systems

PIPING GUIDE TECHNICAL APPLICATION GUIDE GF-136-P. Modulating and Condensing Boilers

APPLICATIONS FOR HVAC SYSTEMS

Radiant Heating Installation Notes

Transcription:

SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES Speciality Chemicals AGAS MPG PROART-0806 Produced for A-Gas (Australia) Pty Ltd 1800 00 2427 www.agas.com PLUS A-Gas (Australia) Pty Limited 9-11 Oxford Road, Laverton North Victoria 3026, Australia +61 3 9368 9222 +61 3 9368 9233 info.au@agas.com A-Gas (SEA) Pte Ltd #10-05 360 Orchard Road Singapore 238869 +65 6836 0065 +65 6836 6521 info.sea@agas.com A-Gas (South Africa) (Pty) Ltd 8 Railway Road, Montague Gardens 7441 Cape Town, South Africa +27 21 551 8790 +27 21 551 8758 info.sa@agas.com A-Gas (UK) Limited Banyard Road, Portbury West Bristol, BS20 7XH, United Kingdom +44 127 537 6600 +44 127 537 6601 info.uk@agas.com A-Gas (Americas) Inc 310 Broad Street Doylestown, PA 18901 USA +1 215 340 7788 +1 215 340 1645 info.americas@agas.com

Secondary Refrigerants like Mono Propylene Glycol are used in the refrigeration cooling requirements. The primary refrigerant is usually expensive, a synthetic greenhouse gas or it can sometimes be a very hazardous product for the operator to handle (eg Ammonia or hydrocarbons). A secondary loop is therefore used to transfer the cool from the primary refrigeration unit around the system using a product with good heat transfer properties, that protects the system from corrosion and is non hazardous for the operator and the public. A-Gas MPG Plus is a non-toxic 'ready to use' heat transfer fluid based on mono propylene glycol that has organic corrosion inhibitors added to keep the secondary system clean and ensure you get optimal corrosion protection. This easy to use product gives freezing and corrosion protection in secondary loop applications down to minus15 deg C. These applications include beer, milk, beverage and fresh fruit cooling systems. A-Gas MPG Plus is compatible with most other mono propylene glycol based heat transfer fluids, but exclusive use of the A-Gas MPG Plus is recommended to maximise the corrosion protection of the system. SPECIFICATIONS: Product: Inhibited Mono Propylene Glycol Colour: Light blue green ph: 8.7 Freeze Point: -15 deg C SG: 1.029 PACKS: 5kg Bottle 20kg Pail 216kg Drum Note: A-Gas MPG Plus can only be used in non contact food cooling applications and can not be used in direct contact with food. Disclaimer: All information contained in this document is accurate to the best of our knowledge and belief as at the time of publication. However, the company makes no warranty or representation, express or implied, as to the accuracy or completeness of such information.

CORROSION PROTECTION Secondary Refrigerants like Mono Propylene Glycol are used in the refrigeration cooling requirements. The secondary refrigerants are designed to operate in closed systems as oxygen in combination with metals will cause corrosion. Most corrosion inhibitors will deplete faster in an open system where oxygen is present. A-Gas MPG Plus is a non-toxic ready to use heat transfer fluid based on mono propylene glycol that has organic corrosion inhibitors added to keep the secondary system clean and ensure you get optimal corrosion protection. This optimised inhibitor package based on carboxylate technology also guarantees a longer lifetime than traditional products. Topping up systems with water is not recommended as the water will decrease the freezing protection level and will dilute the inhibitors allowing corrosion to take place. CORROSION PROTECTION TEST: Weight Loss in mg/coupon ASTM D1384 Brass Steel Cast Iron Aluminium Copper Standard Limit (Max) 10.0 10.0 10.0 30.0 10.0 MPG Std inhibitor 1.0-0.1-0.1-0.9 1.5 A-Gas MPG Plus 0.6 0.2 0.1-2.0 0.9 Note: a negative figure indicates a weight gain Note: A-Gas MPG Concentrate can only be used in non contact food cooling applications and can not be used in direct contact with food. Disclaimer: All information contained in this document is accurate to the best of our knowledge and belief as at the time of publication. However, the company makes no warranty or representation, express or implied, as to the accuracy or completeness of such information.

ENGINEERING GUIDELINES Secondary Refrigerants like Mono Propylene Glycol are used in the refrigeration cooling requirements. The secondary refrigerants are designed to operate in closed systems as oxygen in combination with metals will cause corrosion. Before filling the secondary system with A-Gas MPG Plus the system should be clean and pressure tested. The heat transfer fluid (HTF) should be filled from the lowest point to expel any entrapped air from the high points using mandatory air purging devices installed on the system. Due to expansion of the HTF at lower temperatures the system must be designed with a suitable size expansion tank so the pipes do not burst or seals leak at lower temperatures. It is recommended to use only ready for use products that have been especially and accurately formulated for the freezing temperature selected. Dilution of a concentrate in the field with tap water, especially with high chlorides, will markedly affect the corrosion rate in the system. Only distilled or softened water should be used for dilution if using an MPG concentrate and only if accurate measuring and mixing can be guaranteed. Once filled do not start the system fluid pump until the system has been air purged. To avoid erosion in the system it is recommended that the flow rate is limited to 1.5m/s. Suitable pipe materials are copper, brass, steel, cast iron. ABS and PP plastic pipes can be used but not recommended for low temperatures. Zinc and galvanised steel are not recommended materials for use with mono propylene glycols. It is also recommended that 0.6-0.8mm filter be placed on the pressure side of the pump to trap any corrosion products. For elastomers and materials suitable for seals and valves please refer to the specific information sheet available. Note: A-Gas MPG Concentrate can only be used in non contact food cooling applications and can not be used in direct contact with food. Disclaimer: All information contained in this document is accurate to the best of our knowledge and belief as at the time of publication. However, the company makes no warranty or representation, express or implied, as to the accuracy or completeness of such information.

ELASTOMER COMPATIBILITY Secondary Refrigerants like Mono Propylene Glycol are used in the refrigeration cooling requirements. A-Gas MPG Plus is a non-toxic ready to use heat transfer fluid based on mono propylene glycol that has organic corrosion inhibitors added to keep the secondary system clean and ensure you get optimal corrosion protection. Choice of materials for gasket and pump seal selection is important to prevent leaks from occurring in the closed system. The following list gives some polymers that are expected to be compatible with the A-Gas MPG Plus product. Viton (FPM) Nitrile Rubber (NBR) Ethylene Propylene Diene Rubber (EPDM) Polyethylene (LDPE and HDPE) Polypropylene (PP) Butyl Rubber Neoprene Polyamide Polyvinylchloride (PVC) The manufacturer of the elastomer should be contacted to ensure that the operating temperature range of the heat transfer fluid is compatible to the elastomer selected. The increased viscosity of the A-Gas MPG Plus at lower temperatures must also be allowed for when choosing the pump seal materials. Note: A-Gas MPG Concentrate can only be used in non contact food cooling applications and can not be used in direct contact with food. Disclaimer: All information contained in this document is accurate to the best of our knowledge and belief as at the time of publication. However, the company makes no warranty or representation, express or implied, as to the accuracy or completeness of such information.

SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES SPECIALITY CHEMICALS AND GASES Speciality Chemicals AGAS MPG PROART-0806 Produced for A-Gas (Australia) Pty Ltd 1800 00 2427 www.agas.com CONCENTRATE A-Gas (Australia) Pty Limited 9-11 Oxford Road, Laverton North Victoria 3026, Australia +61 3 9368 9222 +61 3 9368 9233 info.au@agas.com A-Gas (SEA) Pte Ltd #10-05 360 Orchard Road Singapore 238869 +65 6836 0065 +65 6836 6521 info.sea@agas.com A-Gas (South Africa) (Pty) Ltd 8 Railway Road, Montague Gardens 7441 Cape Town, South Africa +27 21 551 8790 +27 21 551 8758 info.sa@agas.com A-Gas (UK) Limited Banyard Road, Portbury West Bristol, BS20 7XH, United Kingdom +44 127 537 6600 +44 127 537 6601 info.uk@agas.com A-Gas (Americas) Inc 310 Broad Street Doylestown, PA 18901 USA +1 215 340 7788 +1 215 340 1645 info.americas@agas.com