552_U 09/14. tekmarnet Thermostat 552 Zoning Replaces: 08/11. User Manual. 1 of 12. A Watts Water Technologies Company _U - 09/14

Similar documents
Thermostat TP42H01 User Manual

U538 12/11. Zoning. Replaces: 08/10. tekmarnet 4 Thermostat 538. User Manual. 1 of U /11

Installation & Operation Manual

- User Brochure Programmable Thermostat 510

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

- User Brochure tekmarnet 4 Setpoint Control 161

Zoning Solutions. Thermostats & Wiring Centers Designed to Maximize Indoor Comfort. A Watts Water Technologies Company

- Data Brochure tekmarnet 4 Thermostat 542e

4 Wiring Brochure Wiring and

- Data Brochure Addendum

- Data Brochure Addendum

- Application Boiler Control 260

- Application A Boiler Control 262 & One Stage Setpoint Control 150. Mechanical Remote Display Module (D1) 040 MODE 1

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Installation & Operation Manual

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

User Guide. Color Touchscreen Programmable Residential Thermostat. ComfortSense Model: 13H /2015 Supersedes 7/2015

Owner s Manual. Part Number 33CSCPACHP-01

Instruction Guide: Thermostat Operation

ComfortSense 7500 Commercial Thermostat. User Guide

Better Design, Better Control, Better Systems.

- Essay Control Functions and Benefits

- Data Brochure Universal Reset Module 423

- Data Brochure Universal Reset Module 422

ComfortSense 7500 Thermostat. User Guide

User s Manual

Elegance. SMT-700 User manual. Ver

- Data Brochure Boiler Control 274

Installation & Operation Manual

TB8220U Commercial Programmable Thermostat OWNER S GUIDE

- Data Brochure. This brochure is for Thermostats 510 and 511 (with sensor). The section on the 079 slab sensor installation is for the 511 only!

Lyric T6 & T6R Smart Thermostat

Digital Thermostat Models: VS30W and VS30B

- Data Brochure Steam Control 279

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Model: Edge-HC. 1 edge-hc

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Operation 8085C ENGLISH. Customer Support: or Visit our webiste Printed in China

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

Radiant Thermostat 519

The Universal Reset Control 363 is a microprocessor based control designed to maximize the comfort and efficiency provided by a hydronic

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

EMERSON BLUE Wireless Comfor t Inter face 1F98EZ-1621 HOMEOWNER USER GUIDE

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

On initial power up the thermostat will guide you through set up procedure for the following:

Model: Available in: Sapphire Black and Glacier White. 1 Series

Wireless Thermostat (WTS10) Keypad Operation Guide

Safety & Installation Instructions

OPERATING INSTRUCTIONS

Installation & Operation Manual

RC-90 / RC-90B Single Stage Heat/Cool Thermostat for Zone Control Systems Installation Instructions

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

RC-2000 Thermostat Installation Instructions

Installation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats

TOUCHSCREEN. COMFORTSENSE Day Programmable Thermostat. 4 Heat / 2 Cool Universal Multi Stage MODEL NUMBER IDENTIFICATION L U FEATURES

Model: Available in : Sapphire Black and Glacier White. 1 Series

MODEL EM-10 ELECTRIC BOILER CONTROL OPERATION AND INSTRUCTION MANUAL

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

INSTRUCTION GUIDE: COLOR TOUCHSCREEN COMMUNICATING THERMOSTAT Color Touchscreen Communicating with Humidity Control Thermostat TPCC32U01.

Programmable Thermostat

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

Model: PRT-TS / PRT-NTS

User s Manual ELITE PROGRAMMABLE THERMOSTAT WITH MENU DRIVEN DISPLAY

T-32-TS Touchscreen Thermostat. Installation Manual

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

Programmable Interactive User Manual

CS027 User Instructions

4 in 1 Digital Thermostat Control

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

HEAT PUMP PROGRAMMABLE THERMOSTAT

Smart Temp. Model

ST9400A User Guide. Features

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

- Data Brochure D 260. Boiler Control /09

RC-112 Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Operating Instructions Model : HC HC-N

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

User Manual. Universal Programmable Smart Wi-Fi Thermostat. For Systems Up to 3 Heat / 2 Cool with Wireless Humidity Control*

IMPORTANT Read and save these instructions. OWNER S GUIDE. ComfortSense 5000 Series Models L5711U and L5732U Programmable Touch Screen Thermostats

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Spas with 2 or 3 Pumps

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

Installation & Operation Manual

User Manual 561_U. WiFi Thermostat 561. Introduction 10/16

Installation & Operation Manual

C-Stat 17-ZW User Instructions

SAS6000UTK-7 UNIVERSAL THERMOSTAT

Commercial Touchscreen Thermostat

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

TC-PHP01-A, TC-PAC01-A Comfort Series Programmable Thermostat. Owner s Manual

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

Installation Instructions

USER S INFORMATION MANUAL

RS332N BUTTON OPERATION INTRODUCTION. Installation and Operation Instructions for REMOVING THE THERMOSTAT FROM THE BACKPLATE

Transcription:

552_U 09/14 tekmarnet Thermostat 552 Zoning Replaces: 08/11 User Manual 1 of 12

This brochure will provide you with the information you need to benefit the most from your tekmarnet thermostat. Please visit www.tekmarcontrols.com for more detailed information on this or any other tekmar product. This thermostat provides heating for one zone in your building. It will maintain your air temperature with an on board room sensor. Floor temperature control may also be enabled in this thermostat when a floor sensor is installed. This thermostat can lower its temperature setting at night or when you are away from the house. Touchscreen Adjustments The touchscreen of this thermostat makes it easy to change commonly used settings. Touch any item to adjust it s setting. You will hear a tick sound each time you touch the display. When you are finished making changes, touching the home button will return to the home screen. If you do not touch the screen for 3 seconds, the home screen is automatically displayed. tekmarnet Thermostat 552 Home Screen Adjust the Time. Adjust the Schedule. Save Energy While on Vacation. Turn the Heat on or Off. Home Button Display the Floor, Outdoor or Set Room Temperature. Room Temperature. Adjust the Temperature. Return to the Home Screen from any menu. Display of the time, schedule and the away key on the home screen is optional and can be turned on or off in the programming menus. To enter the programming menus, press and hold the Home button for 3 seconds. 2 of 12

Display Symbols This thermostat will display symbols on its screen in order to indicate what mode it is in, what temperature it is operating at, or what equipment it is trying to turn on. This section describes each of those symbols. HEAT ON Heat is turned on. SUN Operating at the occupied (day) temperature. MOON Operating at the unoccupied (night) temperature. tekmarnet Communication is present. WARNING SYMBOL Indicates an error is present. ARROWS Adjust the displayed setting. SCENE AWAY Operating at Away temperature. TEMPORARY HOLD Hold for 3, 6, 9 or 12 hours. WWSD The outdoor air temperature is above the Warm Weather Shut Down setting which shuts off the boiler for heating. or or MIN or MAX Reached the room minimum or maximum. MIN FL or MAX FL Reached the floor minimum or maximum. 3 of 12

Adjust the Temperature To change the set temperature, touch the or arrows to select a preferred temperature setting. Press the home button to accept the setting or leave the screen untouched for several seconds. This thermostat is capable of controlling the floor or air temperature. When set to control the floor temperature alone, the large display will say Floor instead of Room. adjusts or The temperature is not adjustable if the thermostat is in the Away scene, the Off mode or has been set to the Limited or Secure access level by the installer. Adjust the Temperature - Temporary Hold Temporary hold allows a user to change the temperature for a period of time and then automatically return to the permanent temperature setting. This is especially useful in commercial buildings that are in use for short amounts of time. When selected, touching the up or down arrows changes the temperature for either 3, 6, 9 or 12 hours. If the thermostat is using a schedule, Schd provides a temporary hold until the next schedule event time. After the temporary hold time expires, the thermostat returns to normal operation. By default, the temporary hold feature is off. When the temporary hold feature is enabled, touching the up or down arrow displays TEMPORARY HOLD. Tap the hour setting until the preferred length of time is displayed. Cancel the temporary hold. Use the Up or Down arrow to select a temperature. HOLD is displayed while the thermostat is operating at the temporary hold temperature. 4 of 12

Mode Heat or Off Heating operation can easily be turned off by selecting the Off mode. Touch the Mode key on the screen to change between Heat and Off. The temperature is not adjustable while the thermostat is off. If near freezing temperatures are detected the system will operate to maintain 40 F (4.5 C), even in the Off mode. or Secondary Temperature Display This thermostat can display the outdoor, floor or room set temperature in the smaller number area at the top right of the screen. To toggle the item currently displayed, touch the secondary temperature. Display of the floor or outdoor temperature requires a connection to an external floor or outdoor air sensor. or Adjust the Time To change the current time, touch the clock on the display. Use the or arrow to change the minutes, hour and day. Touch NEXT ITEM to advance to the next item or BACK for the previous item. To store the new time and date, press the home button, or leave the screen untouched for several seconds. The time is not visible when the thermostat is in the Away scene or if the clock display is turned off in the Time menu. 5 of 12

Programmable Schedule - Day and Night This thermostat is capable of running at a lower temperature setting when you are asleep or out of the building. When the schedule setting is on, day and night temperature settings will display on the screen. If you adjust the temperature while the sun is displayed, the day setting changes. If you adjust the temperature while the moon is displayed, the night setting changes. To adjust the times when the day and night temperature start, touch the sun or moon on the screen. Schedule Menu will display followed by the first adjustable schedule event time. Use the or arrow to adjust the time for each event. or Touch NEXT ITEM to advance to the next event or BACK for the previous event. To accept the settings, press the home button, or leave the screen untouched for several seconds. This thermostats schedule can be set to 2 or 4 events per day repeating on a 24 hr or 7 day cycle. These schedule settings are detailed later in this brochure. Going Away Setting This thermostat can save additional energy while you are away by operating at a lowered temperature. To enable this feature, touch Going Away on the screen. This is only available when the Away Key has been turned on in the Scene menu. Select PERM (permanent) or a number of days using the or arrow. Press the home button to accept the setting or leave the screen untouched for several seconds. Scene Away is displayed on the home screen until the number of days expires. Touch Cancel Away to cancel at any time. The temperature is not adjustable while the thermostat is in Away. Access Levels This thermostat has access levels. It will typically be installed and programmed by a heating professional and then locked in a User, Limited, or Secure access level. System critical settings will not be available for adjustment. For more information on these settings, please consult your installing contractor or this product s Installation and Operation Manual. This brochure focuses on settings available to the User. 6 of 12

Program Menu Settings To Enter the Programming Menus ---------------------------------- Press and hold the Home button for 3 seconds to enter the programming menus. Select a Programming Menu --------------------------------------- Touch NEXT to advance (clockwise in the illustration below) to the next menu. Touch BACK to go backwards (counterclockwise in the illustration below) through the menus. Touch ENTER to enter a menu. Setting Items ------------------------------------------------------- Touch or arrow to adjust the setting if required. Touch NEXT ITEM to advance to the next item within the menu. Touch BACK ITEM to go backwards to the previous item within the menu. To return to the parent menu after changing a setting, press and release the home button. To return to the home screen, press and release the home button twice or wait 30 seconds to automatically return to the home screen. Press and hold for 3 seconds to access the programming menus. 7 of 12

Screen Clean Menu Entering the Screen Clean menu gives you 30 seconds to clean the thermostat and display with a moist cloth. Do not use solvents to clean the thermostat. Set Temp Menu Entering the Set Temp menu allows you to permanently change both the day and night temperature settings for the room and / or floor. If your thermostat is being used for radiant floor heating, a floor sensor can be connected to it. Radiant floors heat the air by raising the floor temperature. Setting a floor temperature is a way of enhancing the comfort of your living space. There are two methods to operating the thermostat using a floor sensor. Floor Temperature Only -------------------------------------------- If the air sensor has been disabled, the thermostat will only maintain floor temperature and ignore air temperature. This operation is recommended for areas such as bathrooms to ensure that tile floors are warm to the touch. Floor and Air Temperature ----------------------------------------- If the air sensor is turned on and a floor sensor is connected, the thermostat will maintain your desired air temperature as well as a minimum floor temperature. This operation is recommended for areas with large windows that allow the sun to shine into a room and keep it warm without the need for heat. This can allow the floors to cool off during the afternoon. When the sun goes down, it can take a long time for the floors to get warm again. This may cause the room to cool off too much in the early evening. A floor minimum setting can help with this condition by maintaining a floor minimum temperature. Keep in mind the floor minimum temperature will override the air temperature, and if set too high, may overheat the room. This operation is also recommended for rooms with hardwood floors. The floor maximum setting prevents damage to the wood floor from overheating. 90 F (32 C) Feels hot to the touch 80 to 85 F (26 to 30 C) Feels warm to the touch 70 F (21 C) Feels cool to the touch Suggested maximum for all floor types other than wood. Bathrooms and kitchens. Suggested maximum for wood floors. Rooms with large windows preventing under heating in the evening. 40 to 45 F (5 to 7 C) Feels cold to the touch Freeze protection for garages. 8 of 12

Time Menu Settings Set date, month and year Required for daylight savings time. Daylight Save Automatic daylight saving time update for the spring and fall. Time Mode Select either 12 or 24 hour time format. Clock Select on to display the time clock in the Home menu (available when schedules are not used). Schedule Menu Settings Lowering the room temperature setting reduces the amount of fuel required to heat the building resulting in energy savings. When operating on a programmable schedule, a or a symbol is shown in the home menu. The or indicates the current operating temperature. All schedules are stored in permanent memory and are not affected by a loss of power. Display Action Day temperature Night temperature This thermostat can operate on a programmable schedule in order to automatically lower the room temperature setting. Options include: Turning off the schedule (OFF) Operate a schedule that applies only to this thermostat zone (ZONE) The ability to operate one of the four system-wide schedules as a master (Schedule Master 1 through 4*) Join one of the four system-wide schedules as a member (Schedule Member 1 though 4*) *Requires the thermostat to be connected to a tekmarnet system. Once the type of schedule has been selected, the thermostat can support schedules that have either: 2 events per day 4 events per day Schedules with four events per day are common for residential use while two events per day are common for commercial installations. 9 of 12

Schedule Menu Settings (Continued) The schedules can be repeated every: 24 hours 7 days (week) A 7 day schedule allows a unique time to be set to change the temperature for each day of the week. The schedule also includes a SKIP option that allows the programmable schedule to skip a temperature change and remain at the previous temperature setting. The SKIP setting can be found between 11:50 PM (23:50 hours) and 12:00 AM (0:00 hours). When a programmable schedule is selected, there is a time delay for the room to warm up from the temperature to the temperature. The thermostat has the option to use Optimum Start to predict the heat up rate of the room. When Optimum Start is set to On, the heating is started in advance to allow the room to reach the Set Room temperature at the time set in the programmable schedule. Display Menu Settings Units Select temperature units in degrees Fahrenheit or Celsius. Backlight Options Select how the display backlight operates. ON = The display is always at full brightness. DIM = When thermostat is not in use, the display is dim but is at full brightness when touched. DIM = When the thermostat is not in use, the display is dim while the schedule or scene is. The display backlight is off when the schedule or scene is. The thermostat display is at full brightness when touched. ON = When the thermostat is not in use, the display is at full brightness when the schedule or scene is. The display backlight is off when the schedule or scene is. The thermostat display is at full brightness when touched. OFF = The display backlight is always off. Secondary Item Select whether the outdoor or floor temperature is shown in the upper right hand corner in the Home menu. Scene Menu Settings Scenes Scenes provide system-wide overrides to save energy. Select whether scenes are not used (none) or if the away scene is available. Away Key If scenes are available, select if the away key is available or not. When used in conjunction with a tekmarnet system control to operate the heating appliance, the domestic hot water tank is not heated while in away scene. 10 of 12

Monitor Menu The monitor menu allows you to view the following temperatures and running hours: Outdoor temperature highs and lows Room temperature highs and lows Floor temperature highs and lows (requires floor sensor to be installed) Heat W1 = Number of hours the thermostat is actively heating the room To clear the temperature highs and lows or the running hours: 1. Touch the temperature or running hours. 2. Display will show. 3. Touch Enter. Toolbox Menu This menu is provides advanced level information. Access Change the access level on the thermostat. Status Info Displays the current status of the thermostat including any overrides from the tekmarnet system control. Toggles between Status Info and the current status. System Normal = Thermostat is operating normally. Override W1 = The tekmarnet system control is either forcing the heating W1 relay on or off. WWSD = Warm Weather Shut Down is in effect. Air Group Master Cool = Heating is off while the cooling system is on. Optimum Start = Heating is started early in order to meet temperature setpoint at Event 1 or Event 3. Floor Max = The floor has reached its maximum temperature. Some under heating could occur. Floor Min = The floor is operating at its minimum temperature. Some over heating could occur. Baseload On = Baseload heating is on even though the room temperature is satisfied. Reduces heat up time when the sun sets in the evening. Software Version and Type Number Display the software SW and the TYPE number. 11 of 12

Frequently Asked Questions Symptom Look for... Corrective Action No heat MODE indicates heat is on. If the is displayed and there is no heat, contact your heating professional. The thermostat is in the Off mode. Touch the mode key to change to Heat. No or key Touch the Cancel Away key on the display. Heat on before scheduled time Touching key does not increase temperature Touching key does not decrease temperature Flashing Flashing Flashing Flashing Optimum Start is on and has turned on the heat in advance of your schedule change. There may be a maximum room temperature set. Consult your heating professional. The floor has reached the floor maximum setting. Consult your heating professional. Warm weather shut down is in effect. Adjustable from your system control. There may be a minimum floor temperature set. Consult your heating professional. More Information This User Brochure contains standard information on how to make adjustments to an installed product. More detailed information can be found in this product s Installation and Operation Manual (552_D) at www.tekmarcontrols.com Product design, software and literature are Copyright 2014 by tekmar Control Systems Ltd.,. Head Offi ce: 5100 Silver Star Road, Vernon, B.C. Canada V1B 3K4, 250-545-7749, Fax. 250-545-0650 Web Site: www.tekmarcontrols.com All specifications are subject to change without notice 12 of 12 552_U - 09/14.