TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Similar documents
Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Multilux 4-Eclipse-Set

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Thermostatic valves with radiator connection systems

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

IMI Heimeier Kit Hydroca ble

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Standard. thermostatic valve body without presetting

thermostatic valve body with stepless precision presetting

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Mikrotherm. Manual Radiator Valves With presetting

Control valves for floor heating systems. Floor Heating Manifolds

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

Floor Control Set. Floor Heating Controller For constant control of the supply temperature

Thermostatic valve bodies

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

Flush individual room control for floor heating systems

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

Thermostatic valve bodies

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Three-way reversing valve

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

Regulux. Radiator lockshield with drain-off facility. To be precise.

Thermostatic head B. Thermostatic heads Secured model designed for public buildings

Halo. Thermostatic heads with built-in sensor

Thermostatic head K. Thermostatic heads with built-in sensor and remote sensor

thermostatic inserts for radiators with integrated valves

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

Art-Line. Absolutely Brilliant Temperature control was never so good

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

HERZ Differential Pressure Control Valve 4002

Automatic balancing valves ASV-PV (new generation) DN 32-50

HERZ Regulating valve 4002

Thermostatic heads. Thermostatic Heads For all thermostatic valve bodies and radiators with integrated valves

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Thermostatic heads. For all thermostatic valve bodies and radiators with integrated valves

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

Globo H. Ball valves Gunmetal ball valve

Installation and operating instructions

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

Radiator Valve Program

Meet Max. Unique AFC technology

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

TS RD 7761 RD, 7761 RD

Convertible radiator valve for one-pipe systems, centre distance 35 mm

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

manifold, for radiators

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

teide termo plus+ HEATING SERIES SCOPE THERMOSTATIC VALVES SERVICE CONDITIONS COMPONENTS TECHNICAL SHEET 07/2017 IP20060 PAG. 1/9

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

RA2000 Commercial TRVs

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

For more information on Pegler Yorkshire visit Heating Controls. Radiator valves with new integral push-fit inlet

AVTI Multifunctional self - acting controller

RA15/6T & TB Conversion Valve

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

Unibox Individual room temperature control and limitation of return temperature in surface heating systems

Energy Saving Series RADICAL

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Thermostatic heads. for all thermostatic valve bodies and radiators with integrated valves. To be precise.

VHX Valve Sets with RAX Thermostatic Sensor for Designer Radiators & Bathroom Towel Rails

Thermostatic Radiator Valves (Caleffi)

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Valves, controls + systems Flow, pressure and temperature balancing

caleffi hydronic valves page 1 of 12

Measuring instruments for hydraulic balancing

2 DESCRIPTION OF SYSTEM COMPONENTS

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

Radical CPD BIM.

SOLUTIONS GUIDE. For total efficiency

RA 2000 Series RA 15/6T & TB Conversion Valve

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

Radiator Trap Radiator Valve

TA-Compact-P. Giving you MORE by giving you LESS

Dynacon Eclipse. Floor Heating Manifolds Floor heating manifold with automatic flow control

CALIS-TS-3-D. HERZ Armaturen. Standard Sheet for 7745, 7746, 7761 Edition 0700 (0999) Three-Way Valves in 3-D Design for One-Pipe Systems

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

Systems for central heating

Acvatix PICV hydronics made easy. The simple and flexible way to energy-efficient HVAC plants with pressure-independent combi valves

Problem-solvers The Radiator Solution Range

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

Transcription:

TRV pack Eclipse Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

IMI HEIMEIER / Thermostatic heads and Radiator valves / TRV pack Eclipse TRV pack Eclipse The IMI Heimeier radiator pack, consists of an automatic flow control TRV body, DX head and lockshield. Designed for application in a two-pipe pumped heating system. The required design flow for each radiator is set directly on the Eclipse valve. This automatic flow limitation is done with a twist and the adjusted flow will then not be exceeded. Even if there is an oversupply of pressure, due to load changes in the system, for example other valves closing or during morning start up, Eclipse will guarantee the desired flow. The thermostatic head with our incompressible liquid-filled sensor guarantees a reliable and precise room temperature control. Key features > > Integrated flow limiter Eliminates over flows and self balances the system > > Angle or axial connection with one kit and straight versions for various installation options > > Flow range from 0 to 0 l/h For high flexibility > > Liquid-filled thermostat for powerful and precise control Technical description Applications area: Heating systems Function: Control Flow limitation Shut-off Dimensions: DN Pressure class: PN 0 Temperature: Max. working temperature: 0 C, with protection cap or actuator 00 C. Min. working temperature: -0 C. Flow range Eclipse: The flow can be pre-set within the range: 0-0 l/h. Delivery setting 0 l/h. (Max. nominal flow q mn at 0 kpa respecting EN : 0 l/h) Differential pressure (ΔpV) Eclipse: Max. differential pressure: kpa (<0 db(a)) Min. differential pressure: 0 00 l/h = 0 kpa 00 0 l/h = kpa Materials: Valve body: Brass O-rings: EPDM rubber Valve disc: EPDM rubber Return spring: Stainless steel Valve insert: Brass, PPS (polyphenylsulphide) Spindle: Niro-steel spindle with double O-ring sealing. Material thermostatic head: ABS, PA6.6GF0, brass, steel, Liquid-filled thermostat. Surface treatment: Valve body and fittings are nickel-plated. Marking: IMI, country code, flow direction arrow, KEYMARK-Designation. II+ Designation. Orange protection cap. Standards: The thermostatic valve bodies meet the following requirements: KEYMARK certified and tested to DIN EN. 0 Pipe connection: G/ male thread with mm compression fitting for copper or precision steel pipe. Connection to thermostatic head and actuator: IMI Heimeier M0x. Thermostatic head DX: Thermostatic head DX with closed graduation cap and liquidfilled thermostat. High actuating force, minimum hysteresis, optimum closing time. Stable control response even with minor calculated p-band variations (< K). Setting numbers 0 IIIII. Frost protection. Temperature range 0 C to 8 C.

Construction Thermostatic valve body Lockshield Replaceable insert The complete thermostatic insert can be replaced using the fitting tool without draining the system.. Strong return spring in combination with high locating force ensures that the valve does not slacken off over time. IMI Heimeier M0x. connection for thermostatic heads and actuators. Automatic flow limiter. Valve body made of Brass. Long-life double O-ring sealing 6. Flow setting 7. Shut-off cone Application The required design flow for each radiator is set directly on the Eclipse valve. This automatic flow limitation is done with a twist and the adjusted flow setpoint will then not be exceeded. Even if there is an oversupply of pressure, either due to load changes in the system, for example other valves closing, or during morning start up. Eclipse will guarantee the requested flow. The valve controls the flow rate independently from differential pressure. Therefore, complicated calculations to determine settings are not necessary. The pressure loss of pipings in old systems does not have to be determined in renovation projects. Only the heating capacity and the resulting max. flow rate have to be determined (see setting chart). The min. differential pressure has to be at the most unfavourable valve. If necessary, it can be measured in order to optimize pump settings (see accessories). The angle Eclipse kit can be installed as angle form or reversed form. The thermostatic head with our incompressible liquid-filled sensor guarantees a reliable and precise room temperature control. Renovation Eclipse replaces old valves with ease as the dimensions conform with the EN standard. All IMI Heimeier thermostatic radiator valves with II+ marking, i.e. Calypso can be retrofitted with Eclipse inserts. Noise behaviour To ensure low-noise performance, the following conditions must be met: The differential pressure above Eclipse should not exceed kpa = 0 mbar = 0,6 bar (<0 db(a)). Flow must be correctly adjusted. The system must be completely deaerated.

IMI HEIMEIER / Thermostatic heads and Radiator valves / TRV pack Eclipse Sample application. Eclipse. Lockshield. STAD balancing valve for maintenance and diagnostics. Boiler Notes To avoid damage and the formation of scale deposit in the hot water heating system, the composition of the heat transfer medium should be in accordance with the VDI guideline 0. For industrial and long-distance energy systems, see the applicable codes VdTÜV and 66/AGFW FW 0. A heat transfer medium containing mineral oils, or any type of lubricant containing mineral oil can have extremely negative effects and usually lead to the disintegration of EPDM seals. When using nitrite-free frost and corrosion resistance solutions with an ethylene glycol base, pay close attention to the details outlined in the manufacturers documentation, particularly concerning concentration and specific additives. Flush the system before changing thermostatic valves in heavy polluted existing systems. The thermostatic valve bodies can be used with all IMI Heimeier thermostatic heads and IMI Heimeier or IMI TA thermal or motorized actuators. The optimal tuning of the components guarantees maximum safety. When using actuators from other manufacturers, make sure that the pressure power is appropriate for thermostatic valve bodies with soft sealing valve discs. Operation Flow setting Stepless setting from to (0 to 0 l/h). The setting is changed using the setting key (article No. 90-0.) or an mm end wrench, to ensure tamper proof setting. Place the setting key on the valve insert. Turn the setting tool so that desired setting value is pointing at the index* on the valve body (see fig.). Remove the key or mm end wrench. The valve is now set. *) SW *) Index Setting l l l l l l l 0 l l l l l/h 0 0 0 0 0 70 80 90 00 0 0 0 0 0 P-band [xp] max. K. P-band [xp] max. K up to 90 l/h.

Diagram l/h db(a)* ) 0 db(a)* ) max. Lowest flow tolerances 0 0 00 80 0 0 min. 0 0 0 0 0 0 0 kpa 0 0 0 70 90 0 0 0 l/h 0-00 l/h: 0 kpa 00-0 l/h: kpa *) P-band [xp] max. K. Setting table Setting values with different radiator performances and system differential temperatures 0 6 7 8 9 0 6 7 8 9 0 0 6 7 8 9 0 0 0 6 6 7 8 8 9 9 00 0 6 6 7 7 7 8 8 9 0 p min. 0-00 l/h = 0 kpa p min. 00-0 l/h = kpa Q = Radiator performance/output power Δt = System differential temperature Δp = Differential pressure Sample: Q = Output power = 000 W, Δt = K Setting value: 6 ( l/h)

IMI HEIMEIER / Thermostatic heads and Radiator valves / TRV pack Eclipse Articles Angle Connectivity in angle or reversed position (see dimensions) DN Connectionradiator Connectionpipe Flow range [l/h] Article No Rp/ mm 0-0 9690-6.800 Straight DN Connectionradiator Connectionpipe Flow range [l/h] Article No Rp/ mm 0-0 9690-6.800 Accessories Setting key for Eclipse. Color orange. Article No 90-0. Fitting tool complete with case, box spanner and replacement seals, for replacing thermostatic inserts without draining off the heating system (for DN 0 to DN 0). Article No Fitting tool 97-00.000 Replacement seals 97-00. Measuring spindle for fitting tool for differential pressure measurement at thermostatic valve bodies with TA-Scope balancing instrument. Article No 9790-0.890 Replacement thermostatic insert with automatic flow limiter for Eclipse. Article No 90-0.00 6

Compression set TA 9 Half coupling Chrome plated Should not be used with PEX-pipes DxA L Article No 8xG/ 6 9-08 0xG/ 7 9-0 xg/ 7 9- xg/ 0 9-6xG/ 9-6 Profile package 0xG/ 7 0 pcs/package 9-0 xg/ 7 0 pcs/package 9- xg/ 0 0 pcs/package 9- d N D Compression set FPL-PX d L For PEX-pipe N Article No D G/ x,7 6- G/ x,0 6- G/ 6 x, 6- ) Over all length. Other accessories, see catalogue leaflet Accessories and spare parts for thermostatic radiator valves. Other couplings, see catalogue leaflet FPL. 7

IMI HEIMEIER / Thermostatic heads and Radiator valves / TRV pack Eclipse Dimensions Angle connection 0 * SW Reversed connection 0 * Straight connection 0 0 * 9 0 0 The products, texts, photographs, graphics and diagrams in this document may be subject to alteration by IMI Hydronic Engineering without prior notice or reasons being given. For the most up to date information about our products and specifications, please visit www.imi-hydronic.com. IMI Eclipse GB 06.06