MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

Similar documents
MAKING MODERN LIVING POSSIBLE. FP975 7-Day Electronic Programmer. User Guide. Danfoss Heating

103E7. User Guide. 7-Day Electronic Timeswitch for Controlling Hot Water and Heating (Including Factory Replacement Units FRU) Danfoss Heating

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

103E5. Installation & User Instructions. Electronic timeswitch for controlling hot water and heating. including Factory Replacement Units (FRU)

3 Channel Multi-Purpose Programmer User Instructions

Installation and User Guide. Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU)

ES3247B. 3 Channel Programmer. User and Installation Instructions

CentaurPlus C27 Series 2 User Operating Instructions

102E7. Installation & User Instructions. 7-day electronic mini-programmer for controlling hot water and heating

CentaurPlus C21 Series 2 User Operating Instructions

425 Coronet Electro-mechanical Timeswitch User Operating Instructions

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

User Operating Instructions Horstmann 425 Tiara/Diadem Electro-mechanical Programmers

MAKING MODERN LIVING POSSIBLE RET2000 B/M/MS. Electronic digital thermostat with LCD User Guide. Danfoss Heating

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

AUTO CM CM USER GUIDE

RF Programmable Room Thermostat User Instructions

ThermoPlus AS2-RF & ASR-RF Installation Instructions

ST9400A User Guide. Features

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

RET2000 MD Electronic digital thermostat with LCD, delayed start. Danfoss Heating. Installation Guide

Model: RT510RF. Installation Manual

Operating Instructions Model : HC HC-N

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

Installation and User Guide. Electro-mechanical mini programmer for controlling hot water and heating Including Factory Replacement Units (FRU)

Drayton Digistat +3RF

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

CS027 User Instructions

Installation & User Instructions

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

C-Stat 17-ZW User Instructions

TPOne-S. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Basic Plus2 Room Thermostats Floor Heating

MAKING MODERN LIVING POSSIBLE. Danfoss Heating. RET2000 B/M/MS Electronic digital thermostat with LCD Installation Guide

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

GreenCon On/Off Room Thermostat

Operating instructions

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Operating Instructions

Model: Slimline-B. Battery Series

CET2000B-RF + RX1-S + CS2

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

Operating Instructions Model: PRT/HW - PRT/HW-N Version 3. 09/09 Revision 2 Ref: PRT/HW/NV3

Elegance. SMT-700 User manual. Ver

irad Wireless Controller

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

ESRTP4RF. RF Programmable Room Thermostat with TPI, Optimum Stop, Delayed & Optimum Start. User and Installation Instructions

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Model: Touch-RF. 1 Wireless Series

User Instructions For TopTronic RS-30

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

User Guide for EHE & EHE Programmable Room Thermostat

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

User Manual THR870CUK Programmable Thermostat

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

User Guide Y9420H Sundial RF 2 Pack 2

OWNER S MANUAL Venstar Inc. 08/07

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

Model: Edge-HC. 1 edge-hc

Lyric T6 & T6R Smart Thermostat

Battery Powered Electronic Programmable Room Thermostat

CET B-RF Wireless Electronic Hot Water Cylinder Thermostat User & Installation Instructions

Model: Available in: Sapphire Black and Glacier White. 1 Series

USERS GUIDE. Electronic Timer, 7 day. LOGIC+ Combi, LOGIC Combi & LOGIC Combi E 24, 30, 35

Mynute. Standard efficiency system boiler 12e - 16e - 20e. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Electronic Dual Cylinder Thermostat User Instructions

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

DOMESTIC HEATING CONTROLS ARE EASY PART 2 - TIMERS & PROGRAMMERS

Model: Available in : Sapphire Black and Glacier White. 1 Series

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual

Digital Room Thermostat

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

R. Boiler Energy Management System FW 200. Operating Instructions for the User (2010/05)

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

Underfloor Heating Programmable Thermostat

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

8000 Series Programmable & Non-Programmable Thermostats for Heat/Cool Applications

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

Model: Touch-RS. 1 Touch-RS

Model: Slimline-RF. 1 Slimline Series

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

Model: PRT-TS / PRT-NTS

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

User Instructions. Electronic Programable Room Thermostats. HC8000 Series Heat/Cool & HP8000 Heat Pump Thermostats LCD DISPLAY.

Operating your heating system with the Prefect PRE5701 Programable Thermostat

ELECTRONIC THERMOSTAT

PRT-TS WiFi PRT-TS WiFi

: PRT / PRT PRT / PRT-N1

Control Packs Catalogue. Including control packs compliant with 2013 Building Regulations: Part L

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

4 in 1 Digital Thermostat Control

Transcription:

MAKING MODERN LIVING POSSIBLE CP715Si Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water Danfoss Heating User Guide

CP715Si Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water For a large print version of these instructions please call Marketing on 0845 121 7400. Certification Mark Danfoss can accept no responsibility for possible errors in catalogues, brochures, and other printed material. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 2 CP715SI

Thank you for buying a Danfoss product Danfoss Heating 3

Index 1.0 User Instructions 1.1 Your Programmer...6 1.2 Preset Programmes...6 1.3 Before you start...7 1.4 Choice of 24hr or AM/PM display...7 1.5 Setting the Date and Time...7 1.6 Accepting the Preset Programmes...8 1.7 Before you Change the Preset Programmes...9 1.7.1 Programming the Heating in 5/2 Day Mode... 10 1.7.2 Programming the Heating in 7 Day Mode... 11 1.7.3 Programming the Heating in 24 Hour Mode... 12 1.8 Running your Programme... 14 2.0 Advanced 2.1 Temporary Override Buttons... 15 2.2 Holiday Programme... 16 2.3 Changing Clocks Forward and Backward... 17 2.4 Service Interval Timer... 18 2.5 Making a Full Reset... 19 2.6 Fault Check List... 20 Central Heating 1HR override Hot Water 1HR override Central Heating MAN override +1HR MAN +1HR MAN Hot Water MAN override Hot Water Mode SELECT Central Heating Mode SELECT RESET 4 CP715SI

The text below has been edited and approved by the Plain English Campaign, who has issued a Crystal Mark to be displayed with it. What is a Programmer?... an explanation for householders. Programmers allow you to set On and Off time periods. Some models switch the central heating and domestic hot water on and off at the same time, while others allow the domestic hot water and heating to come on and go off at different times. Set the On and Off time periods to suit your own lifestyle. On some programmers you must also set whether you want the heating and hot water to run continuously, run under the chosen On and Off heating periods, or be permanently off. The time on the programmer must be correct. Some types have to be adjusted in spring and autumn at the changes between Greenwich Mean Time and British Summer Time. You may be able to temporarily adjust the heating programme, for example, Override, Advance or Boost. These are explained in the manufacturer s instructions. The heating will not work if the room thermostat has switched the heating off. And, if you have a hot-water cylinder, the water heating will not work if the cylinder thermostat detects that the hot water has reached the correct temperature. Danfoss Heating 5

1.0 User Instructions 1.1 Your Programmer The CP715 Si allows you to switch your heating and hot water on and off at times that suit you. You can programme up to 3 ON/OFF times per day for the heating and the hot water and the two systems can be operated independently. 1.2 Preset Programmes Your CP715 Si comes ready programmed with a set of operating times which often suit most people. Event No. Hot Water and Heating Mon-Fri Sat-Sun** 1 1st ON 6:30 7:30 2 1st OFF 8:30 10:00 3* 2nd ON* 12:00* 12:00* 4* 2nd OFF* 12:00* 12:00* 5 3rd ON 17:00 17:00 6 3rd OFF 22:30 22:30 * Not applicable if unit set to 2 ON/OFFs per day by installer **Not applicable if unit set to 24 hour mode by installer See page 9 for explanations of different settings If you want to change any of these settings, you can do so by following the instructions on pages 9-14. First, follow the steps on page 7-8 to set the correct time and date. 6 CP715SI

1.3 Before you start Open the flap on the front of the clock. Press the RESET button using a non-metallic object (e.g. pencil/matchstick) until you hear a click and the 2 red lights on the front of the unit flash once. This will stop and restart the electronics, without losing the factory set time and date settings. To fully reset the unit see page 19. 1.4 Choice of 24hr or AM/PM display Press and hold and NEXT ON/ OFF for 1.5 seconds to toggle between 24hr clock and AM/PM display, as required. 1.5 Setting the Date and Time These settings are made during manufacture and only need to be changed in the unlikely event that the unit has lost the settings. Setting the Date Press and hold PROG for 5 seconds to display year. Use the + or - buttons to set the correct year. Danfoss Heating 7

Press to display day and month. Use the + or - buttons to set the correct month (Jan = 1, Feb = 2 etc.). Press to display day and month. Use the + or - buttons to set day of month. Press PROG to display the time. The words SET TIME will appear at the top of the display and the time will flash on and off. Use the + or - buttons to set the correct time (press and hold to change in 10 min. increments). Setting the Day The day of the week is set automatically. 1.6 Accepting the preset programmes If you are happy to use the preset programmes on page 6, you don t need to do anything else. To accept the factory presets just press the PROG button once until the time appears and the colon in the display begins to flash. Your unit is now in RUN mode and will control your heating and hot water according to the preset programmes. 8 CP715SI

1.7 Before you change the preset programmes Your installer will have set your unit to operate in one of the following modes: 5/2 day - one set of programmes for weekdays and another for weekends (page 10-11) 7 day - different settings for each day of the week. (page 11-12) 24 hour - one set of programmes for the whole week. (page 12-13) See INSTALLER SETTING tick box on inside flap label to ascertain which mode your unit is set. INSTALLER SETTING 24 Hour 5+2 Day 7 Day Please Note The unit must be programmed in sequence. ON/OFF times cannot be set out of sequence. If you want to leave a preset time as it is, simply press NEXT to move on to the next setting. Your installer will have set your unit to programme either 2 or 3 ON/OFFs per day. If your clock has been installed to allow 3 ON/ OFFs and you do not wish to use one of the ON/OFF settings, simply programme the ON time to be the same as the OFF time and the setting will not operate. Danfoss Heating 9

1.7.1 Programming the heating and hot water in 5/2 day mode 1. Press PROG once until SET ON TIME appears at the top of the display and MOTUWETHFR appears at the bottom of the display. Use the + or - buttons to set the time you would like your heating/ hot water to first come on in the morning (Event 1). 2. Press NEXT ON/OFF once only. Use the + or - buttons to set the time you want your heating/hot water to go off (Event 2). To move to the next setting, i.e. when you would like your heating/ hot water to come on again (Event 3) press the NEXT ON/OFF button again. 3. Continue programming the heating/hot water ON and OFF times for weekday Events 4, 5 and 6 as in Step 2. 4. Press the button once and SASU will appear at the bottom of the display. 10 CP715SI

5. To set the times required for SA and SU repeat steps 1-3 or if the same settings are required press COPY. 6. Press the PROG button to return the unit to RUN mode (time appears and colon in the display begins to flash). 7. Proceed to page 14. Please Note If this setting is made on a weekend day SASU will show in place of MOTUWETHFR. 1.7.2 Programming the heating and hot water in 7 day mode 1. Press PROG once until SET ON TIME appears at the top of the display. Note the current day is displayed. Press the button until the required day is displayed. 2. Use the + or - buttons to set the time you want your heating/hot water to first come on in the morning (Event 1). 3. Press NEXT ON/OFF to move to Event 2. Danfoss Heating 11

4. Continue programming the heating/hot water ON and OFF times in this way by using the + or - buttons to set the time you want and pressing the NEXT ON/ OFF button to move to the next setting. 5. Press button once only. The next day will appear at the bottom of the display. 6. Repeat steps 2-6 to set the required programme for the day. 7. Press the PROG button to return the unit to RUN mode (time appears and the colon in the display begins to flash). 8. Proceed to page 14. 1.7.3 Programming the heating and hot water in 24 hour mode 1. Press PROG once until SET ON TIME appears at the top of the display. Use the + or - buttons to set the time you want your heating/ hot water to first come on in the morning (Event 1). 2. Press NEXT ON/OFF to move to Event 2. 12 CP715SI

Continue programming the heating/hot water ON and OFF times by pressing: a) NEXT ON/OFF button to move to the next setting, b) + or - buttons to amend the time. 3. Press the PROG button twice to return the unit to RUN mode (time appears and the colon in the display begins to flash). 4. Proceed to page 14. Danfoss Heating 13

1.8 Running Your Programme To run the central heating programme: press the SELECT button next to the radiator symbol until AUTO is displayed in the LCD. To run the hot water programme: press the SELECT button next to the tap symbol until AUTO is displayed in the LCD. As you press the SELECT button the display will change between ON, OFF, ALLDAY and AUTO. AUTO = the heating/hot water will come on and go off at the programmed times. ON = the heating/hot water will remain on constantly. OFF = the heating/hot water will not come on. ALLDAY = the clock will turn the heating/hot water on at the first programmed ON and will leave it on until your last programmed OFF. Select the option you require depending on your circumstances, time of year, etc. 14 CP715SI

2.0 Advanced Settings 2.1 Temporary Override Buttons Sometimes you may need to change the way you use your heating temporarily, i.e. due to unusually cold weather. The CP715 Si has two convenient overrides which can be selected without affecting the set programme. +1HR +1HR MAN +1HR +1HR MAN MAN MAN The grey buttons next to the radiator symbol are the Heating override buttons. The grey buttons next to the tap symbol are the Hot Water override buttons. +1HR MAN Pressing this button when either system is in AUTO or ALLDAY mode will cause the heating/hot water to remain on for an extra hour. If it is pressed while the programme is OFF the heating/hot water will come on immediately for 1 hour then go off again. +1HR will be shown in the display. Pressing this button when either system is in AUTO or ALLDAY mode will cause the heating/hot water to go OFF until the next programmed ON, or vice versa. MAN will be shown in the display. Danfoss Heating 15

2.2 Holiday Programme To automatically bring the heating back on when returning from holiday the CP715-Si has a built in holiday feature. Follow the steps below to set the date that the heating system needs to come back on. 1. Press 2. Use the + or - buttons to select the year. 3. Press, then use the + and - buttons to select the month. 4. Press again, then use the + and - buttons to select the day in month. 5. Press to turn heating off and enter holiday mode. To cancel holiday mode press. 16 CP715SI

2.3 Changing Clocks Forward and Backward This is handled automatically. Should the installer have turned off Automatic Time Change then follow the instructions below. Open the flap on the front of the unit to reveal the programming buttons. To change from Summer to Winter (clocks back) - press and hold - button To change from Winter to Summer (clocks forward) - press and hold + button! Take care when making this change for the first time. If it is made in the wrong direction the unit will have to be reset and any user-settings re-entered. (See pages 7-8 on how to reset the unit and how to set the date, time and day). Danfoss Heating 17

2.4 Service Interval Timer If the property is owned by a landlord he may, for gas safety reasons, have instructed the installer to set the service interval timer. If set, 28 days prior to the boiler service due date, a momentary visual and audible warning will remind you to have the boiler serviced in the next 28 days. This will be repeated each day at noon. If the boiler is not serviced within 28 days the daily audible warning will sound for 1 minute at the beginning of each hour and must be cancelled each day by pressing any button on the unit. In addition, all overrides and programming buttons will be disabled and the heating and hot water will operate for a set portion of each programmed hour. The installer will cancel or reset the service interval timer as part of the boiler service. This is a gas safety feature that can only be accessed by an installer. When the service interval timer is set the service due date can be viewed in RUN mode by pressing and holding the COPY button. 18 CP715SI

2.5 Making a Full Reset If it is necessary to fully reset the unit, excluding the date and time, follow the instructions below. 1. Press and hold the +1HR and MAN buttons on the left hand side of the product. +1HR MAN +1HR MAN 2. Press the RESET button and hold for 3 seconds. 3. Release the RESET button. The display will change to show the current time. Example 4. Finally, release both the +1HR and MAN buttons. The unit is now fully reset and must be re-programmed, see pages 10-14. Danfoss Heating 19

2.6 Fault Check List CP715 CP715 20 CP715SI

Danfoss Heating 21

22 CP715SI

Danfoss Heating 23

Danfoss Ltd. Ampthill Road Bedford MK42 9ER Tel: 01234 364621 Fax: 01234 219705 Email: ukheating@danfoss.com Website: www.heating.danfoss.co.uk Part No.38159v01s7-06 01/11