VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

Similar documents
VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

VA G 052 S

SPECTRACOOL Indoor & Outdoor Air Conditioners

5736 N. Michigan Road Indianapolis, IN 46228

5736 N. Michigan Road Indianapolis, IN 46228

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL INDOOR/OUTDOOR

G /6000 BTU/Hr. 1172/1758 Watt

G /6000 BTU/Hr. 1172/1758 Watt

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

N Volt 1800 BTU/Hr. 527 Watt

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

N Volt 1800 BTU/Hr. 527 Watt

GENESIS Indoor Air Conditioners

Top-Mount Air Conditioners

PROAIR Harsh Environment/Wash Down Air Conditioners

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

CHAPTER12. Thermal Management. Featured Products in this Chapter. Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P.

Quality Enclosures. Service Excellence.

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products

Thermal Management INDEX. Management. Thermal TM-1

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Construction. Electrical. Enclosure Protection IS19 - Industry Standards UL Recognized Type 3, 3R, 4 & 12 IEC IP56

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

CENTRAL SPLIT UNIT UNIC

Multi Inverter Air Conditioning Condensing Units - Summary

Condensing Units CUS 15-60

MAC N-407 Air-Cooled Chiller

Ruud Achiever Series Air Conditioners

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

Air Conditioning THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

MACH N-407 Heat Pump Air-Cooled Chiller

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ USA Phone: web:

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Service Parts for RMR Wall-Mount Enclosures

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

SEALED ENCLOSURE COOLING

FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

Quality Products. Service Excellence.

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

PUHZ-SHW140YHA PUHZ-SHW230YKA

Split System Cooling Product & Performance Data

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Quality Enclosures. Service Excellence.

Packaged Terminal Air Conditioner (PTAC)

T-Series Air Conditioner T15 Model

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

TOP 29 QUESTIONS PROSPECTIVE ENCLOSURE COOLING THERMAL EDGE CUSTOMERS ASKED BY Thermal Edge, Inc

General Description. Operation

CDP 40 SWIMMING POOL DEHUMIDIFIER

Technical data LA 9S-TU

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

CDP 40T SWIMMING POOL DEHUMIDIFIER FEATURES

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

Commercial High-Efficiency Condensing Units

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

Wall-Mount Cabinets. Pretreated steel coated with light-gray, low-gloss, lightly textured RAL 7035 polyester powder

Condensing Units & Air Handlers

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Technical Data ISU Series. Underceiling/Console Split System Air Conditioners kw 15 kw

Wall-Mount Cabinets PROTEK Single-Door and Double-Hinged Cabinets

Wall-Mount Cabinets. Pretreated steel coated with light-gray, low-gloss, lightly textured RAL 7035 polyester powder

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

13 GEP A L P - 1 A

30GT FLOTRONIC AIR-COOLED CHILLERS

SPXA / SPXA-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

Technical data LA 28TBS

ENGINEERING SPECIFICATIONS

AMERICAN STANDARD 14 MODELS 4A7B E

ENGINEERING SPECIFICATIONS

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

RACK-MOUNT Air Conditioners

Technical Data Ducted Three Phase Split System Air Conditioner

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

TECHNICAL MANUAL CX(E) SPLIT SYSTEMS. Tel: Fax:

T-Series Air Conditioner T53 Model

13 SEER CONDENSING UNITS & AIR HANDLERS

Incremental Comfort Conditioners

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Transcription:

V-Series Mid-Size Air Conditioners (Now done by MGDC) VA08 Indoor Model 1200, 1500 and 2000 Watts INDUSTRY STANDARDS IP 56 Internal Air Loop IP 34 External Air Loop APPLICATION Industrial drive enclosures Automotive assembly systems Packaging equipment Material handling Other process control systems FEATURES Coated coils for filterless operation in most manufacturing environments Convenient quick-fastening terminal block for easy power connections Built-in installation hooks on the back of the unit Unique passive condensate management system Indoor operating temperature range from 20 C to 55 C IP 56 protection against dust and water infiltration Reliable mechanical thermostat to reduce the chance of failure Digital display and malfunction switch optional All-metal shroud for rugged factory conditions Exterior surface mounting standard Partial recessed mounting options Full-size cutout print included with every unit Easy access to the optional aluminum filter and other components Rigorously tested to withstand shipping vibration, high temperatures and other operating challenges Every unit functionally tested prior to leaving the factory Rotary compressor for energy efficiency R134A earth-friendly refrigerant and RoHS compliant Outdoor AC models also include: - Malfunction Switch - Compressor heater - Compressor head pressure control - Enclosure heater 2000W - Corrosion resistant components - Operating temperature range -40 C - 55 C SPECIFICATIONS 1200, 1500 and 2000 nominal watts 230 VAC 50 Hz power input with +/-10 percent operating range and certifications FINISH RAL 7035 light-gray, semi-textured powder-coat paint standard Other colors and textures available upon request Model Number Structure VA 08 06 25 G 052 S 1 2 3 4 5 6 7 1. Identifies the of air conditioner type, VA=V Series Air Conditioner. 2. Identifies the approximate height, 08=708mm to 800mm. 3. This is the air conditioner s nominal capacity in Watts, 08=800 W. 4. Identifies the input power of air conditioner, 2=220V/230V, 5=50Hz. 5. Identifies the construction material and refrigerant of air conditioner, G=Galvanized sheet metal and R134a. 6. Unique set of numbers for each air conditioner which identifies the accessories on a model, 052=Indoor, Teminal block and finger guard. 7. S=Standard product. NOTES Visit www.pentairprotect.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 1 Thermal Management SUBJECT TO CHANGE WITHOUT NOTI nvent.com/hoffman

Performance Data 1200 W, 1500 W, 2000 W MODEL NUMBER Indoor Model Indoor Model Partial Recessed Mount Indoor Model with Display and Malfunction Switch Outdoor Model with Heat Package COOLING PERFORMAN Nominal: L35 L35 Watt 1200 1550 1950 L35 L50 Watt 930 1280 1700 Refrigerant R134a R134a R134a Refrigerant Charge (g) 462 652 765 Operating Temperature Range: Maximum ( C) 55 55 55 Minimum ( C) (indoor/outdoor) 20/-40 20/-40 20/-40 Airflow at 0 Static Pressure: Internal loop (m 3 /h) 345 530 530 External loop (m 3 /h) 275 545 565 Max. Heater Watts for Outdoor Models: 2000 2000 2000 Duty Cycle 100% 100% 100% ELECTRICAL DATA Rated Voltage 230 230 230 Frequency (Hz) 50 50 50 Operating Range /-10% /-10% /-10% Max. Power Consumption L35 L35 (Watts) 565 610 855 Max. Power Consumption L35 L50 (Watts) 700 760 1100 Max. Nominal Current (Amps) 3.4 3.7 5.6 Starting Current (Amps) 16.2 16.3 22.7 Pre-fuse T (Amps) 10 10 10 Agency Approvals Power Input Description Terminal Block Terminal Block Terminal Block PERFORMAN FACTOR L35 L35 Cooling Performance (Watt)/ 2.1 2.5 2.3 Power Consumption (Watt) PERFORMAN FACTOR L35 L50 Cooling Performance (Watt)/ 1.3 1.7 1.6 Power Consumption (Watt) ENCLOSURE PROTECTION IP Code IP 56 Internal loop IP34 External loop CONTROLLER Description Basic Mechanical Thermostat Thermostat Location Enclosure Side Factory Thermostat Setting ( C) 35 SOUND LEVEL At 1 M 68 dba 71 dba 73 dba UNIT CONSTRUCTION Material Galvanized Sheet Metal Standard Finish RAL 7035 light-gray, semi-textured powder-coat paint standard UNIT DIMENSIONS Height (mm) 725 725 725 Width (mm) 431 431 431 Depth (mm) 237 237 237 Weight (kg) 37 38 41 nvent.com/hoffman PH 763.422.2211 Thermal Management 2

Performance Curves for 1200 and 1500 Watt Models VA081225GXXXS 1200 Watt Capacity Curves 230V/50Hz 2000 1800 1600 1400 Capacity (Watts) 1200 1000 800 600 400 200 20 25 30 35 40 45 50 55 60 Ambient Temp ( C) VA081525GXXXS 1500 Watt Capacity Curves 230V/50Hz 2500 2300 2100 Capacity (Watts) 1900 1700 1500 1300 1100 900 700 500 20 25 30 35 40 45 50 55 60 Ambient Temp ( C) 3 Thermal Management SUBJECT TO CHANGE WITHOUT NOTI nvent.com/hoffman

Performance Curves for 2000 Watt Model VA082025GXXXS 2000 Watt Capacity Curves 230V/50Hz 3500 3200 2900 2600 Capacity (Watts) 2300 2000 1700 1400 1100 800 500 20 25 30 35 40 45 50 55 60 Ambient Temp ( C) nvent.com/hoffman PH 763.422.2211 Thermal Management 4

VA08 V-SERIES Mid-size 1st Angle Projection Note: 1. Mounting gasket supplied (not shown) 2. Units: mm 89084471 5 Thermal Management SUBJECT TO CHANGE WITHOUT NOTI nvent.com/hoffman

VA08 V-SERIES Mid-size Partial Recess 1st Angle Projection 463 113 POWER INPUT ENCLOSURE AIR IN AMBIENT AIR OUT 786 COOL STAT 756 725 REMOVABLE HANGING TABS MOUNTING BOLTS (18) AMBIENT AIR IN ENCLOSURE AIR OUT 237 94 493 89104638 CLEANABLE,REUSABLE ALUMINUM INLET FILTER BEHIND REMOVABLE PANEL Note: 1. Mounting gasket supplied (not shown) 2. Units: mm 431 ACSS HOLE TO 9.6mm O.D. DRAIN STUB nvent.com/hoffman PH 763.422.2211 Thermal Management 6